• Treffer 13 von 105
Zurück zur Trefferliste

Emissions of reaction products and sound from outdoor and indoor firework displays

  • This work presents results of investigations towards the emission of chemical reaction products and sound pressure during an outdoor and an indoor firework display. Potentially harmful and toxic gases, and aerosols, were measured as well as sound pressures. Aerosols were measured with a Differential Mobility Analyzer (DMA) as well as a Laser Particle Counter. The focus was on particles with diameters between 11 nm and 20 µm. A transportable Fourier Transform Infrared (FTIR) spectroscopy detector registered the concentrations of emitted reaction gases, simultaneously. During the outdoor firework display, peak particle concentrations of >550000 particles cm-3, equivalent to a mass concentration of approximately 3.95 mg m-3, were detected, revealing a concentration maximum at approximately 175 nm particle diameter. The time-averaged particle mass concentration did not exceed 1.58 mg m-3 over 15 minutes. Due to the large distances (110 m) to the firing points, no significant harmful orThis work presents results of investigations towards the emission of chemical reaction products and sound pressure during an outdoor and an indoor firework display. Potentially harmful and toxic gases, and aerosols, were measured as well as sound pressures. Aerosols were measured with a Differential Mobility Analyzer (DMA) as well as a Laser Particle Counter. The focus was on particles with diameters between 11 nm and 20 µm. A transportable Fourier Transform Infrared (FTIR) spectroscopy detector registered the concentrations of emitted reaction gases, simultaneously. During the outdoor firework display, peak particle concentrations of >550000 particles cm-3, equivalent to a mass concentration of approximately 3.95 mg m-3, were detected, revealing a concentration maximum at approximately 175 nm particle diameter. The time-averaged particle mass concentration did not exceed 1.58 mg m-3 over 15 minutes. Due to the large distances (110 m) to the firing points, no significant harmful or toxic gas concentrations were measured during the entire firework display. In contrast, concentrations of sulphur dioxide (SO2) rose after an indoor firework display in a large event hall. On two days, more than 23000 particles cm-3 (which equates to a mass concentration of approximately 0.41 mg m-3) were detected when the hall ventilation was turned off, and more than 11000 particles cm-3 (which equates to a mass concentration of approximately 1.18 mg m-3) when the hall ventilation was activated. Concentration maxima appeared at approximately 300 nm particle diameter. The time-averaged particle concentrations in this case did not exceed 0.56 mg m-3 (over 15 minutes).zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Andreas Dutschke, Stefan SeegerORCiD, Lutz Kurth, Ulrich PanneORCiD, Christian Lohrer
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of pyrotechnics
Jahr der Erstveröffentlichung:2009
Verlagsort:Whitewater, Colo.
Ausgabe/Heft:28
Erste Seite:78
Letzte Seite:93
Freie Schlagwörter:Aerosols; Combustion gases; Pyrotechnic articles
ISSN:1082-3999
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Nein
Einverstanden