Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 9 von 34
Zurück zur Trefferliste

Determination of elements in river water

  • The need for quality assessment of anthropogenic impact on environmental pollution is increasing due to discharge from various industries, the use of chemicals in agriculture and the consumption of fossil fuels. Diminishing resources such as natural waters used for the cultivation of agricultural products, plant and animal habitats are under severe pollution pressure and are at constant risk. Several parameters, such as Pb, Cd, Ni, Hg were listed by Water Framework Directive in Directive(2008/105/EC) in the priority substances. Cadmium and Hg were identified as priority hazardous substances whereas As is an important contaminant for its potential toxicological and carcinogenic effects. An inter-comparison study is organised in EURAMET TC-MC in order to demonstrate the capability participants for measuring five elements in river water. The participants carried out measurements for analytes: Pb, Cd, Ni and As as mandatory elements, and Se as an optional one. Participants were asked toThe need for quality assessment of anthropogenic impact on environmental pollution is increasing due to discharge from various industries, the use of chemicals in agriculture and the consumption of fossil fuels. Diminishing resources such as natural waters used for the cultivation of agricultural products, plant and animal habitats are under severe pollution pressure and are at constant risk. Several parameters, such as Pb, Cd, Ni, Hg were listed by Water Framework Directive in Directive(2008/105/EC) in the priority substances. Cadmium and Hg were identified as priority hazardous substances whereas As is an important contaminant for its potential toxicological and carcinogenic effects. An inter-comparison study is organised in EURAMET TC-MC in order to demonstrate the capability participants for measuring five elements in river water. The participants carried out measurements for analytes: Pb, Cd, Ni and As as mandatory elements, and Se as an optional one. Participants were asked to perform the measurements with respect to the protocol provided. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Can-et-al_EURAMET-QM-S11-elements-in-river-water_Metrologia-2023.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:S. Z. Can, B. A. Engin, A. İşleyen, A. Jotanovic, O. Acosta, P. Prina, M. Schvartz, M. Savić, M. Stojanović, D. A. Ahumada, J. P. Abella, T. Näykki, T. Saro-Aho, Jochen VoglORCiD, Maren Koenig, O. Rienitz, J. Noordmann, C. Pape, J. Towara, E. Kakoulides, C. Alexopoulos, R. Ketrin, E. Mardika, I. Komalasari, C. Elishian, E. Naujalis, B. Knašienė, C. Uribe, E. Carrasco, A. Zoń, B. Warzywoda, A. Stakheev, V. Dobrovolskiy, T. Stolboushkina, A. Glinkova, E. Sobina, T. Tabatchikova, L. Gažević, M. Paunovic, R. Jaćimović, T. Zuliani, R. P. Zambra, R. Napoli
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Metrologia
Jahr der Erstveröffentlichung:2023
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.1 Anorganische Spurenanalytik
Verlag:BIPM & IOP Publishing Ltd
Jahrgang/Band:60
Ausgabe/Heft:1a
Aufsatznummer:08001
Erste Seite:1
Letzte Seite:40
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Metrology; River water; Toxic elements; Traceability
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
DOI:10.1088/0026-1394/60/1A/08001
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:04.01.2023
Referierte Publikation:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.