A new concept for steam generator tube integrity assessment

  • Steam generator (SG) tubes are part of the primary circuit of pressurised water reactors and therefore also part of the pressure retaining boundary components. Furthermore, steam generator tubes are the components which guarantee the separation between the primary and secondary circuits. Therefore the knowledge of the loss of tube integrity as soon as possible is an essential. Optimised nondestructive testing methods based on the eddy current array technique are used to find material degradation, especially intergranular stress corrosion cracks during the periodical in-service inspection. These methods are supported by the measurement of the leakage rate during operation based on radioactivity and Tritium measurement regarding a high crack grows. Shutdown criteria depending on leakage rates which are described in the operation procedures but there are no specifications about the conditions for the measured leakage. Is the leakage coming from a single crack or are there multiple cracksSteam generator (SG) tubes are part of the primary circuit of pressurised water reactors and therefore also part of the pressure retaining boundary components. Furthermore, steam generator tubes are the components which guarantee the separation between the primary and secondary circuits. Therefore the knowledge of the loss of tube integrity as soon as possible is an essential. Optimised nondestructive testing methods based on the eddy current array technique are used to find material degradation, especially intergranular stress corrosion cracks during the periodical in-service inspection. These methods are supported by the measurement of the leakage rate during operation based on radioactivity and Tritium measurement regarding a high crack grows. Shutdown criteria depending on leakage rates which are described in the operation procedures but there are no specifications about the conditions for the measured leakage. Is the leakage coming from a single crack or are there multiple cracks or is this the leakage of a critical crack. With the help of FE calculations answer about the uncertainties of leakage rate versus critical crack grows were found. Shutdown criteria must guarantee to avoid critical crack sizes, i.e. between the measured tritium activity and the critical crack size must be a safety gap.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Anton Erhard, X. Schuler, Frank Otremba
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Nuclear engineering and design
Jahr der Erstveröffentlichung:2012
Verlag:North-Holland Publ. Co.
Verlagsort:Amsterdam
Jahrgang/Band:249
Erste Seite:297
Letzte Seite:303
Freie Schlagwörter:Axial cracks; Crack detection; Crack opening area; Critical crack sizes; Leakage; Non destructive testing; Steam generator tubes
DOI:10.1016/j.nucengdes.2012.04.014
ISSN:0029-5493
ISSN:1872-759X
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:14.06.2012