• Treffer 17 von 46
Zurück zur Trefferliste

Rail tank car total containment fire testing: planning & test development

  • Given the frequent incidences of Non-Accident Releases (NARs) of hazardous materials from tank cars, there in an increasing interest in transporting hazardous materials in total containment conditions (i.e., no pressure relief devices). However, the ability of tank cars to meet thermal protection requirements provided in the Code of Federal Regulations under conditions of total containment has not been established. Also, the modeling tool commonly used by industry to evaluate thermal protection, AFFTAC, has not been validated under these conditions. The intent of this effort was to evaluate through a series of third-scale fire tests, the ability of tank cars to meet the thermal protection requirements under total containment conditions, and also, to validate AFFTAC for such conditions. This paper describes the test design and planning effort associated with this research, including the design and evaluation of a fire test setup to simulate a credible, fully engulfing, pool fire thatGiven the frequent incidences of Non-Accident Releases (NARs) of hazardous materials from tank cars, there in an increasing interest in transporting hazardous materials in total containment conditions (i.e., no pressure relief devices). However, the ability of tank cars to meet thermal protection requirements provided in the Code of Federal Regulations under conditions of total containment has not been established. Also, the modeling tool commonly used by industry to evaluate thermal protection, AFFTAC, has not been validated under these conditions. The intent of this effort was to evaluate through a series of third-scale fire tests, the ability of tank cars to meet the thermal protection requirements under total containment conditions, and also, to validate AFFTAC for such conditions. This paper describes the test design and planning effort associated with this research, including the design and evaluation of a fire test setup to simulate a credible, fully engulfing, pool fire that is consistent and repeatable, and the design and hydro-static testing of a third-scale tank specimen. The fire design includes controls on the spatial distribution and temperature variation of the flame temperature, the heat flux, and the radiative balance, to best reflect large liquid hydrocarbon pool fire conditions that may be experienced during derailment scenarios.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Rail tank car total containment fire testing - planning and test development.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:F. Gonzalez III, A. Prabhakaran, A. Robitaille, G. Booth, A.M. Birk, Frank Otremba
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):JRC2015 - Joint rail conference (Proceedings)
Jahr der Erstveröffentlichung:2015
Herausgeber (Institution):ASME
Erste Seite:5764, 1
Letzte Seite:6
Veranstaltung:JRC2015 - Joint rail conference
Veranstaltungsort:San Jose, CA, USA
Beginndatum der Veranstaltung:23.03.2015
Enddatum der Veranstaltung:26.03.2015
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:20.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:05.07.2018
Einverstanden