Correction of diffuse X-ray detector based background

  • A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (“backlight”) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation. Moreover, theA novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (“backlight”) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation. Moreover, the local intensity mismatch depends on the attenuation of the sample. We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Axel Lange, Manfred P. Hentschel, Andreas KupschORCiD, Bernd R. MüllerORCiD
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):DIR 2011 - International symposium on digital industrial raidology and computed tomography (Proceedings)
Jahr der Erstveröffentlichung:2011
Veröffentlichende Institution:Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlag:Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP)
Ausgabe/Heft:DGZfP-BB 128 (Poster 24)
Erste Seite:1
Letzte Seite:7
Freie Schlagwörter:Backlight; Computed tomography; Fluorescence screen; Synchrotron radiography; X-ray detector
Veranstaltung:DIR 2011 - International symposium on digital industrial raidology and computed tomography
Veranstaltungsort:Berlin, Germany
Beginndatum der Veranstaltung:20.06.2011
Enddatum der Veranstaltung:22.06.2011
URN:urn:nbn:de:kobv:b43-243589
ISBN:978-3-940283-34-4
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung-Keine Bearbeitung
Datum der Freischaltung:31.12.2015
Referierte Publikation:Nein
Schriftenreihen ohne Nummerierung:Wissenschaftliche Artikel der BAM