• Treffer 8 von 9
Zurück zur Trefferliste

MR-based eddy current probe design for hidden defects

  • We present a simulation study which pursues the objective to find probe geometries for a MR-based eddy current (EC) probe (MR magneto resistance, e.g., GMR giant magneto resistance, TMR tunnel magneto resistance). MR sensor technology exhibits two significant advantages compared with conventional coil systems. First, MR sensors are relatively frequency-independent within common EC-frequency ranges which enable us to operate them in hidden defects testing problems. Secondly, MR technology is well suited for miniaturization helping us to design small elements in the order of below 100 µm. In this paper simulation and experimental results obtained with the probes for low frequency application, i.e. for hidden defects detection are discussed. Our simulations are based on two different approaches for a better validation, a commercial finite element method software (Opera, Vectorfields) and the semi-analytical software CIVA. We investigated both coil arrangement in order to excite sufficientWe present a simulation study which pursues the objective to find probe geometries for a MR-based eddy current (EC) probe (MR magneto resistance, e.g., GMR giant magneto resistance, TMR tunnel magneto resistance). MR sensor technology exhibits two significant advantages compared with conventional coil systems. First, MR sensors are relatively frequency-independent within common EC-frequency ranges which enable us to operate them in hidden defects testing problems. Secondly, MR technology is well suited for miniaturization helping us to design small elements in the order of below 100 µm. In this paper simulation and experimental results obtained with the probes for low frequency application, i.e. for hidden defects detection are discussed. Our simulations are based on two different approaches for a better validation, a commercial finite element method software (Opera, Vectorfields) and the semi-analytical software CIVA. We investigated both coil arrangement in order to excite sufficient high eddy currents inside the test samples and position of MR-elements at the array chip. In doing so the MR sensors were positioned that they are not exposed to excitation fields. In addition, different coil geometries, in particular coil length, e.g. Ι = 20 mm, were analyzed in order to generate a consistent eddy current distribution beneath an array of up to 32 MR-elements. To prove obtained probe principles we built GMR-EC-probes. The first test measurements are in good agreement with the simulations performed by BAM and CEA. On basis of our findings the IMAGIC consortium developed new MR-EC-probes using integrated ASIC technology.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Matthias Pelkner, Thomas Erthner, Verena Reimund, Marc Kreutzbruck, N. Sergeeva-Chollet
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):ECNDT 2014 - 11th European conference on non-destructive testing (Proceedings)
Jahr der Erstveröffentlichung:2014
Herausgeber (Institution):Brno University of Technology
Erste Seite:1
Letzte Seite:8(?)
Freie Schlagwörter:Eddy current (EC); GMR; Hidden defects; Magnetic flux leakage; Magneto resistance (MR); Simulation
Veranstaltung:ECNDT 2014 - 11th European conference on non-destructive testing
Veranstaltungsort:Prague, Czech Republic
Beginndatum der Veranstaltung:2014-10-06
Enddatum der Veranstaltung:2014-10-10
URL:http://www.ndt.net/events/ECNDT2014/app/content/Paper/409_Pelkner.pdf
ISBN:978-80-214-5018-9
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:20.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:15.12.2014
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.