Distributed Fibre Optic Acoustic and Vibration Sensors for Industrial Monitoring Applications

  • We investigate the usability of distributed fibre optic acoustic sensing (DAS) for innovative and advanced monitoring applications in industrial and civil infrastructure installations. In this paper, we report on our ongoing application-oriented research activities regarding the utilization of DAS based on coherent optical time-domain reflectometry (C-OTDR) for condition monitoring of a variety of infrastructures. Specifically, our research presented here aims at acoustic condition monitoring of and fault detection in pipelines and industrial piping systems, at acoustic condition monitoring of rollers in industrial conveyor belt installations, and at acoustic condition monitoring of and threat detection in extensive submarine power cables, respectively. Furthermore, we show a method to mitigate the effect of sensitivity fading of C-OTDR based DAS due to unstable environmental conditions via the modification of the sensor fibre. This can help to provide a continuous adequate sensorWe investigate the usability of distributed fibre optic acoustic sensing (DAS) for innovative and advanced monitoring applications in industrial and civil infrastructure installations. In this paper, we report on our ongoing application-oriented research activities regarding the utilization of DAS based on coherent optical time-domain reflectometry (C-OTDR) for condition monitoring of a variety of infrastructures. Specifically, our research presented here aims at acoustic condition monitoring of and fault detection in pipelines and industrial piping systems, at acoustic condition monitoring of rollers in industrial conveyor belt installations, and at acoustic condition monitoring of and threat detection in extensive submarine power cables, respectively. Furthermore, we show a method to mitigate the effect of sensitivity fading of C-OTDR based DAS due to unstable environmental conditions via the modification of the sensor fibre. This can help to provide a continuous adequate sensor functionality for a number of different industrial monitoring applications.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • sensor2017_paper_final_published.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Konstantin HickeORCiD, Maria-Teresa Hussels, René Eisermann, Sebastian Chruscicki, Katerina Krebber
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Proceedings AMA Conferences 2017 with SENSOR and IRS2
Jahr der Erstveröffentlichung:2017
Verlag:AMA Service GmbH
Verlagsort:Wunstorf
Erste Seite:274
Letzte Seite:279
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:C-OTDR; condition monitoring; distributed acoustic sensing; fibre optic sensors; industrial monitoring
Veranstaltung:SENSOR 2017 - 18th International Conference on Sensors and Measurement Technology
Veranstaltungsort:Nuremberg, Germany
Beginndatum der Veranstaltung:30.05.2017
Enddatum der Veranstaltung:01.06.2017
DOI:10.5162/sensor2017/B7.3
ISBN:978-3-9816876-4-4
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")