• Treffer 1 von 0
Zurück zur Trefferliste

X-ray compton line scan tomography

  • The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (withoutThe potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • 120.110799.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Andreas KupschORCiD, Axel Lange, Manfred P. Hentschel, Gerd-Rüdiger Jaenisch, N. Kardjilov, C. Tötzke, H. Markötter, A. Hilger, I. Manke
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Eigenverlag BAM
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Materials testing
Jahr der Erstveröffentlichung:2015
Verlag:Hanser
Verlagsort:München
Jahrgang/Band:57
Ausgabe/Heft:11-12
Erste Seite:985
Letzte Seite:991
Freie Schlagwörter:Computed tomography; Neutron tomography; X-ray compton scattering
DOI:10.3139/120.110799
ISSN:0025-5300
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:20.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:25.11.2015
Einverstanden