Development of a reliable test method for laser printers, copiers and multifunctional devices in emission test chambers - Part 1

  • Background to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (“Blue angel“) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to today’s requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study newBackground to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (“Blue angel“) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to today’s requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study new criteria for the Blauer Engel for copiers, printers and a new created for multifunctional devices, concerning TVOC, ozone and dust emission were determined. Additionally a model is presented calculating the concentrations in real rooms under usual printing conditions derived from the test chamber results.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Jens Rockstroh, Oliver Jann, Olaf WilkeORCiD, Wolfgang HornORCiD
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Gefahrstoffe, Reinhaltung der Luft = Air quality control
Jahr der Erstveröffentlichung:2005
Herausgeber (Institution):BGIA, Institut für Arbeitsschutz
Verlag:Springer-VDI-Verl.
Verlagsort:Düsseldorf
Jahrgang/Band:65
Ausgabe/Heft:3
Erste Seite:71
Letzte Seite:80
ISSN:0949-8036
ISSN:0039-0771
ISSN:1436-4891
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:17.03.2005
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.