Ethanol/water solutions as certified reference materials for breath alcohol analyzer calibration

  • The Federal Institute for Materials Research and Testing (BAM), Germany, has issued a series of large volume ethanol in water certified reference materials (CRMs), primarily developed for the calibration of evidential breath alcohol analyzers in Germany. The certified parameter is the ethanol mass concentration at 20 °C. When used in a wet bath simulator, the solutions deliver gas samples that meet the requirements set by the Organization of Legal Metrology for calibration of breathalyzers. The materials were prepared gravimetrically by spiking of ethanol into water in single 5 L units. A complete uncertainty budget for the preparation process has been established. The purity of the commercial ethanol stock solution was identified to be the main source of uncertainty. For stability and homogeneity measurements and for the verification of the gravimetric mass concentration of the CRMs, a robust high-precision gas chromatography, with flame-ionization detection method for ethanolThe Federal Institute for Materials Research and Testing (BAM), Germany, has issued a series of large volume ethanol in water certified reference materials (CRMs), primarily developed for the calibration of evidential breath alcohol analyzers in Germany. The certified parameter is the ethanol mass concentration at 20 °C. When used in a wet bath simulator, the solutions deliver gas samples that meet the requirements set by the Organization of Legal Metrology for calibration of breathalyzers. The materials were prepared gravimetrically by spiking of ethanol into water in single 5 L units. A complete uncertainty budget for the preparation process has been established. The purity of the commercial ethanol stock solution was identified to be the main source of uncertainty. For stability and homogeneity measurements and for the verification of the gravimetric mass concentration of the CRMs, a robust high-precision gas chromatography, with flame-ionization detection method for ethanol determination in aqueous samples was developed and validated. The good performance of this method has been demonstrated in several international comparisons organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry at the International Bureau of Weights and Measures.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Rosemarie Philipp, Olaf Hanebeck, Sebastian Hein, Wolfram Bremser, Tin Win, Irene Nehls
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Accreditation and quality assurance
Jahr der Erstveröffentlichung:2010
Verlag:Springer
Verlagsort:Berlin
Jahrgang/Band:15
Ausgabe/Heft:3
Erste Seite:141
Letzte Seite:146
Freie Schlagwörter:Breath alcohol; Certified reference material; Ethanol in water; GC-FID
DOI:10.1007/s00769-009-0605-9
ISSN:0949-1775
ISSN:1432-0517
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:18.03.2010
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.