VOC- and SVOC-Emissions from Adhesives, Floor Coverings and Complete Floor Structures

  • Emissions of volatile organic compounds (VOC) and semivolatile organic compounds (SVOC) from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 °C, 50% relative humidity and an area specific air flow rate of q = 1.25 m3/m2 h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different permeability of flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same types of emission and emission rates as the individual floor coverings themselves. Emissions from the carpet-covered structure resulted also from the lower layers. In all cases emissions from the complete structures were lower than the sum of emissions from the singleEmissions of volatile organic compounds (VOC) and semivolatile organic compounds (SVOC) from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 °C, 50% relative humidity and an area specific air flow rate of q = 1.25 m3/m2 h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different permeability of flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same types of emission and emission rates as the individual floor coverings themselves. Emissions from the carpet-covered structure resulted also from the lower layers. In all cases emissions from the complete structures were lower than the sum of emissions from the single components. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Olaf WilkeORCiD, Oliver Jann, Doris Brödner
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Indoor air
Jahr der Erstveröffentlichung:2004
Verlag:Danish Techn. Pr.
Verlagsort:Copenhagen
Jahrgang/Band:14
Ausgabe/Heft:Suppl. 8
Erste Seite:96
Letzte Seite:105
DOI:10.1111/j.1600-0668.2004.00314.x
ISSN:0905-6947
ISSN:1600-0668
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Bibliotheksstandort:ZJ 128
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:13.12.2004
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.