Iterative numerical 2D-modeling for quantification of material defects by pulsed thermography
- Pulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects. Typically, analytical 1D models are used to determine the defect depth of flat-bottom holes (FBH), grooves or delamination. However, these models cannot take into account lateral heat flows, or only to a limited extent. They are therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Here, we present an approach for quantitative determination of the geometry for FBH or grooves. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a groove or FBH and its diameter of width. The model takes lateral heat flows into account as well as thermal losses. Figure 1 shows the temperature increase of a pulsed thermography measurement at three differentPulsed thermography is a well-known non-destructive testing technique and has proven to be a valuable tool for examination of material defects. Typically, analytical 1D models are used to determine the defect depth of flat-bottom holes (FBH), grooves or delamination. However, these models cannot take into account lateral heat flows, or only to a limited extent. They are therefore limited by the FBHs aspect ratio (diameter to remaining wall thickness), to ensure that the heat flow above the defect can still be described one-dimensionally. Here, we present an approach for quantitative determination of the geometry for FBH or grooves. For this purpose, the results of a numerical 2D model are fitted to experimental data, e.g., to determine simultaneously the defect depth of a groove or FBH and its diameter of width. The model takes lateral heat flows into account as well as thermal losses. Figure 1 shows the temperature increase of a pulsed thermography measurement at three different locations on the sample. The numerical model is fitted to the experimental data (red lines) to quantify the groove. The numerical simulation matches the experimental data well.…
Autor*innen: | Raphael Bernegger |
---|---|
Koautor*innen: | Simon Altenburg, Christiane Maierhofer |
Dokumenttyp: | Vortrag |
Veröffentlichungsform: | Präsentation |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2018 |
Organisationseinheit der BAM: | 8 Zerstörungsfreie Prüfung |
8 Zerstörungsfreie Prüfung / 8.0 Abteilungsleitung und andere | |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Freie Schlagwörter: | 2D model; Data reconstruction; Flat bottom holes; Notches; Numerical modelling; Opaque materials; Pulse thermography |
Themenfelder/Aktivitätsfelder der BAM: | Chemie und Prozesstechnik |
Veranstaltung: | 45th Annual Review of Progress in Quantitative Nondestructive Evaluation |
Veranstaltungsort: | Burlington, VT, USA |
Beginndatum der Veranstaltung: | 15.07.2018 |
Enddatum der Veranstaltung: | 19.07.2018 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 24.10.2018 |
Referierte Publikation: | Nein |
Eingeladener Vortrag: | Nein |