• Treffer 1 von 1
Zurück zur Trefferliste

Reference-free X-ray fluorescence analysis of an ancient Chinese ceramic

  • The investigation of an ancient Chinese ceramic served to further develop and validate fundamental parameter-based quantitation procedures in reference-free x-ray fluorescence (XRF) analysis. The XRF measurements of this sample were performed at the four-crystal monochromator beamline of the Physikalisch-Technische Bundesanstalt (PTB) at the BESSY II synchrotron radiation facility employing different excitation energies. The parallel processing of the XRF spectra recorded at different excitation energies provides a means to simultaneously evaluate relevant fundamental parameters and secondary enhancement processes such as those induced by photoelectrons. Employing well-characterized and absolutely calibrated instrumentation, all experimental parameters involved in XRF are known for small relative uncertainties allowing for a completely reference-free quantitation. Apart from traces of rare earth elements, the analytical results of the Chinese ceramic achieved by reference-free XRF areThe investigation of an ancient Chinese ceramic served to further develop and validate fundamental parameter-based quantitation procedures in reference-free x-ray fluorescence (XRF) analysis. The XRF measurements of this sample were performed at the four-crystal monochromator beamline of the Physikalisch-Technische Bundesanstalt (PTB) at the BESSY II synchrotron radiation facility employing different excitation energies. The parallel processing of the XRF spectra recorded at different excitation energies provides a means to simultaneously evaluate relevant fundamental parameters and secondary enhancement processes such as those induced by photoelectrons. Employing well-characterized and absolutely calibrated instrumentation, all experimental parameters involved in XRF are known for small relative uncertainties allowing for a completely reference-free quantitation. Apart from traces of rare earth elements, the analytical results of the Chinese ceramic achieved by reference-free XRF are in line with target values given within a proficiency test of the International Atomic Energy Agency (IAEA) involving atomic and nuclear methods.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:B. Beckhoff, M. Kolbe, Oliver Hahn, A.G. Karydas, C. Zarkadas, D. Sokaras, M. Mantler
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):X-ray spectrometry
Jahr der Erstveröffentlichung:2008
Verlag:Wiley
Verlagsort:Chichester
Jahrgang/Band:37
Erste Seite:462
Letzte Seite:465
Freie Schlagwörter:Archaeometry; Cultural heritage; XRF
DOI:10.1002/xrs.1073
ISSN:0049-8246
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:19.03.2009
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.