Modified SIBIE procedure for ungrouted tendon ducts applied to scanning impact-echo

  • The impact-echo method has been successfully applied to identify defects inside concrete. In addition, to detect ungrouted tendon ducts in a large concrete slab, a scanning impact-echo technique is developed. However, since resonant frequencies in the spectrum responsible for the travel paths via defects are only taken into account, the method could lead to erroneous results due to complicated spectra obtained in the tests. Consequently, Stack Imaging of spectral amplitudes Based on Impact-Echo (SIBIE) procedure has been developed to improve the data interpretation. Conventionally, SIBIE is applied to a single measurement data and a point information of defects is obtained at the area, where the impact test is performed. In this study, SIBIE is applied to scanning impact-echo data. Locations of ungrouted tendon ducts embedded in a large concrete specimen are investigated. In order to visualize the whole cross-section tested, the SIBIE analysis is modified, introducing an ellipticalThe impact-echo method has been successfully applied to identify defects inside concrete. In addition, to detect ungrouted tendon ducts in a large concrete slab, a scanning impact-echo technique is developed. However, since resonant frequencies in the spectrum responsible for the travel paths via defects are only taken into account, the method could lead to erroneous results due to complicated spectra obtained in the tests. Consequently, Stack Imaging of spectral amplitudes Based on Impact-Echo (SIBIE) procedure has been developed to improve the data interpretation. Conventionally, SIBIE is applied to a single measurement data and a point information of defects is obtained at the area, where the impact test is performed. In this study, SIBIE is applied to scanning impact-echo data. Locations of ungrouted tendon ducts embedded in a large concrete specimen are investigated. In order to visualize the whole cross-section tested, the SIBIE analysis is modified, introducing an elliptical integration mode. It is demonstrated that ungrouted tendon ducts are successfully located by the modified SIBIE analysis, whereas results of the conventional B-scan analysis are not so good as the modified SIBIE analysis.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Ninel Alver, Herbert WiggenhauserORCiD
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Construction and building materials
Jahr der Erstveröffentlichung:2010
Verlag:Elsevier Science
Verlagsort:Amsterdam
Jahrgang/Band:24
Ausgabe/Heft:12
Erste Seite:2388
Letzte Seite:2392
Freie Schlagwörter:Impact echo; SIBIE; Scanning procedure
DOI:10.1016/j.conbuildmat.2010.05.012
ISSN:0950-0618
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:05.07.2011