• Treffer 9 von 79
Zurück zur Trefferliste

Influence of illuminance on indication detectability during visual testing

  • Visually detecting irregularities on components is a complex process, influenced by physical, technical, and human factors. Current standards mainly focus on illuminance, demanding highest accuracy for it, without providing scientific justification. In this research, 63 inspectors visually inspected forgings, with and without crack-like indications. The influence of illuminance on probability of detection was investigated. Therefore, illuminance was varied in three steps (200 lx, 350 lx, 500 lx). Human factors (e.g., experience, motivation) were recorded by using questionnaires. The results show no significant difference in probability of detection between the three illuminance levels. Equal probability of detection rates could be achieved at illuminances below and at the required threshold (500 lx). A difference in illuminance was found between the measurement point and the test area of the respective participant. This leads to higher assumed illuminance than present on the component.Visually detecting irregularities on components is a complex process, influenced by physical, technical, and human factors. Current standards mainly focus on illuminance, demanding highest accuracy for it, without providing scientific justification. In this research, 63 inspectors visually inspected forgings, with and without crack-like indications. The influence of illuminance on probability of detection was investigated. Therefore, illuminance was varied in three steps (200 lx, 350 lx, 500 lx). Human factors (e.g., experience, motivation) were recorded by using questionnaires. The results show no significant difference in probability of detection between the three illuminance levels. Equal probability of detection rates could be achieved at illuminances below and at the required threshold (500 lx). A difference in illuminance was found between the measurement point and the test area of the respective participant. This leads to higher assumed illuminance than present on the component. Compared with the measurement accuracy of the used illuminance meter, none of these deviations could be used to explain the similar results at different illuminance. The fact that illuminance has a significant influence in detecting indications has been disproven for this case. Whether human factors can provide explanation for the results remains unclear. This will be investigated in further research.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Blankschaen et al (2022) Influence of illuminance on indication detectability during VT_ref Pub.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:M. Blankschän, D. Kanzler, Marija Bertovic, Martina Rosenthal, R. Liebich
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Materials Testing
Jahr der Erstveröffentlichung:2022
Organisationseinheit der BAM:8 Zerstörungsfreie Prüfung
8 Zerstörungsfreie Prüfung / 8.4 Akustische und elektromagnetische Verfahren
Verlag:De Gruyter
Jahrgang/Band:64
Ausgabe/Heft:10
Erste Seite:1532
Letzte Seite:1543
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Illuminance; Non-destructive testing; Probability of detection; Reliability; Visual inspection
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
DOI:10.1515/mt-2022-0112
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:19.10.2022
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:24.10.2022
Einverstanden