• Treffer 1 von 401
Zurück zur Trefferliste

Simulation and experimental determination of the self ignition of tetrafluoroethylene in a 100-dm³-autoclave

  • The gaseous TFE is a monomer which is used to form PTFE, also known as Teflon®, by a polymerisation process at elevated conditions of temperature and pressure. TFE belongs to the group of chemically instable gases which are able to decompose under specific conditions releasing a huge amount of heat comparable to a gas explosion of flammable gases. Due to several incidents in PTFE – production plants the investigation of the safety related properties of TFE at elevated condition was necessary and resulted in a research project at BAM which is subsidized by the PlasticsEurope association. In a first stage the pressure dependence of the Minimum Ignition Temperature for Decomposition (MITD) was determined in the range of 0.5 MPa - 3 MPa in small autoclaves with volumes of 0.2 dm³ and 3 dm³. These results were used to validate the numerical model and were found to correlate quite well with the simulated values. Nevertheless the applicability had to be confirmed for larger volumes as well.The gaseous TFE is a monomer which is used to form PTFE, also known as Teflon®, by a polymerisation process at elevated conditions of temperature and pressure. TFE belongs to the group of chemically instable gases which are able to decompose under specific conditions releasing a huge amount of heat comparable to a gas explosion of flammable gases. Due to several incidents in PTFE – production plants the investigation of the safety related properties of TFE at elevated condition was necessary and resulted in a research project at BAM which is subsidized by the PlasticsEurope association. In a first stage the pressure dependence of the Minimum Ignition Temperature for Decomposition (MITD) was determined in the range of 0.5 MPa - 3 MPa in small autoclaves with volumes of 0.2 dm³ and 3 dm³. These results were used to validate the numerical model and were found to correlate quite well with the simulated values. Nevertheless the applicability had to be confirmed for larger volumes as well. Therefore a heat able 100-dm³-autoclave was constructed and build to determine the MITD in the range of 0.5 MPa to 1.1 MPa.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • MBK ECCE_2011.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Martin Kluge
Koautor*innen:Fabio Ferrero, Robert Zeps
Dokumenttyp:Posterpräsentation
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2011
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:Ignition temperature; MITD; Self decomposition; TFE; Tetrafluoroehtylene
Veranstaltung:8th European Congress of Chemical Engineering
Veranstaltungsort:Berlin, Germany
Beginndatum der Veranstaltung:25.09.2011
Enddatum der Veranstaltung:29.09.2011
Bemerkung:
Das Poster hat den Adolf-Martens-Preis im Bereich "Safety Engineering" erhalten. - The poster was awarded the Adolf Martens Prize in the section "Safety Engineering".
Bemerkung:
Geburtsname von Kluge, Martin: Beckmann-Kluge, M. -  Birth name of Kluge, Martin: Beckmann-Kluge, M.
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:04.10.2022
Referierte Publikation:Nein
Einverstanden