TY - JOUR A1 - Schulz, Eckhard A1 - Kalinka, Gerhard A1 - Meretz, S. A1 - Hampe, Andreas T1 - Pull-out of Single Fibres KW - Verstärkungsfaser KW - Verbundwerkstoffe KW - Interface KW - Adhäsion KW - Reibung KW - Haftung KW - Thermoplast PY - 1994 SN - 0945-0084 VL - 84 IS - 5 SP - 25 EP - 26 PB - Hanser CY - München AN - OPUS4-11989 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schulz, Eckhard A1 - Kalinka, Gerhard A1 - Meretz, S. A1 - Hampe, Andreas T1 - Einzelfaserauszug - Eine Methode zum Bestimmen der Grenzflächenfestigkeit KW - Verstärkungsfaser KW - Verbundwerkstoffe KW - Interface KW - Adhäsion KW - Reibung KW - Haftung KW - Thermoplast PY - 1994 SN - 0023-5563 VL - 84 IS - 5 SP - 608 EP - 610 PB - Hanser CY - München AN - OPUS4-11994 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hampe, Andreas A1 - Kalinka, Gerhard A1 - Meretz, S. A1 - Schulz, Eckhard T1 - An advanced equipment for single-fibre pull-out test designed to monitor the fracture process KW - Verbundwerkstoffe KW - Thermoplaste KW - Adhäsion KW - Reibung KW - Haftung KW - Interface KW - Schubfestigkeit KW - Scherfestigkeit KW - Messmethode PY - 1995 SN - 0010-4361 VL - 26 IS - 1 SP - 40 EP - 46 PB - Butterworth-Heinemann CY - Guildford, Surrey AN - OPUS4-11988 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kalinka, Gerhard A1 - Leistner, André A1 - Hampe, Andreas T1 - Characterisation of the fibre/matrix interface in reinforced polymers by the push-in technique N2 - The push-in test is the only micromechanical test method that is not restricted to artificial fibre/matrix arrangements, but allows the in situ characterisation of interfaces in composites fabricated and stressed under realistic conditions. However, with the application of this method to reinforced polymers some problems arise both in the mathematical model for evaluating test data and in the practical performance of the test. Because in some cases the deformation of the relatively compliant polymeric matrices cannot be neglected, an extension of the existing model is required. For this purpose, the elastic energy of the material around the debonded part of the fibre is estimated and included in the energy-balance analysis. Because of the small diameter of the fibres usually used for reinforcing polymers, a test apparatus was designed which ensures a high positioning accuracy in the xy plane as well as in the z direction. In order to minimise thermal and mechanical influences, the microscope for fibre selection and the force sensor/indenter are directly connected together and the apparatus is designed to be stiff in all components. A solid-state bending joint guarantees very precise control of the axial movement. Three examples of the application of this easy-to-handle and low-cost test apparatus are presented briefly in the paper: assess fibre/matrix combinations, measures to improve the interfacial adhesion and the influence of water on the interface. KW - Interface KW - Test method KW - Characterisation KW - Indentation KW - Push-in PY - 1997 SN - 0266-3538 VL - 57 IS - 8 SP - 845 EP - 851 PB - Elsevier CY - Barking AN - OPUS4-12011 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -