TY - CONF A1 - Hoffmann, Holger A1 - Knizia, Christian A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Evaluation of a polyclonal anti-sulfamethoxazole and a monoclonal anti-estrone antibody in different types of environmental water samples T2 - 15th International Conference on Chemistry and the Environment (EuChems) CY - Leipzig DA - 2015-09-20 PY - 2015 AN - OPUS4-34515 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sötebier, Carina A1 - Bierkandt, Frank A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Analysis of Silver Nanoparticles Using AF4 Coupled to ICP-MS: Investigating Sample Loss and Recovery Rates T2 - 10th International Conference on the Environmental Effects of Nanoparticles and Nanomaterials ICEENN 2015 CY - Vienna, Austria DA - 2015-09-06 PY - 2015 AN - OPUS4-34098 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jakubowski, Norbert A1 - Lindner, Uwe A1 - Lingott, Jana A1 - Panne, Ulrich A1 - Richter, Silke T1 - Determination and Speciation of Lanthanoides by ICP-MS T2 - Analysis of Rare Earth Elements, Methods and Application (AREE 2015) CY - Kleve, Germany DA - 2015-10-05 PY - 2015 AN - OPUS4-34523 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Unger, Wolfgang A1 - Dietrich, Paul A1 - Nietzold, Carolin A1 - Ivanov-Pankov, S. A1 - Lippitz, Andreas A1 - Weigel, W. A1 - Panne, Ulrich T1 - Surface Chemical Analysis of Carbohydrates on Epoxy-Functionalized Surfaces T2 - 16th European Conference on Applications of Surface and Interface Analysis (ECASIA 15) CY - Granada, Spain DA - 2015-09-28 PY - 2015 AN - OPUS4-34812 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Demidov, Alexandr A1 - Eschlboeck-Fuchs, S A1 - Gornushkin, Igor B. A1 - Huber, N. A1 - Heitz, J. A1 - Roessler, R. A1 - Schmid, Thomas A1 - Panne, Ulrich T1 - Two calibration-free approaches of analysis of industrial oxides by laser-induced breakdown spectroskopy T2 - EMSLIBS 2015 CY - Linz, Austria DA - 2015-09-14 PY - 2015 AN - OPUS4-35166 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Fettig, Ina A1 - Philipp, Rosemarie A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - Critical pollutant tributyltin in surface water systems T2 - ICCE 2015 CY - Leipzig, Germany DA - 2015-09-20 PY - 2015 AN - OPUS4-35001 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Michalik-Onichimowska, Aleksandra A1 - Riedel, Jens A1 - Panne, Ulrich T1 - Monitoring of Thiol-Ene Coupling by Mass Spectrometry and Ion Mobility Spectrometry N2 - The carbon-sulfur bond is frequently occurring in natural products and pharmaceuticals. In a wide range of industrial applications such as polymers and bioorganic functionalization, biomaterials and nanostructured networks formation and microdevice fabrication the targeted construction of C-S bonds is being synthetically important. The synthesis of thioethers is mainly conducted by radical thiol-ene click reactions typically initiated by thermal or UV activation of a radical initiator or direct radical formation via UV irradiation. The reported conversion yields are high after relatively short irradiation times, thus, a fast reaction monitoring is necessary to optimize reaction conditions in terms of total yield and occurrence of undesired by-products. Especially for fast reactions, rapid response is the key feature for online monitoring. The latter gets increasingly important in process analytical approaches for quality assurance and to better control the conversion rate by feedback control. For a headspace analysis, gas detection methods like ion mobility spectrometry (IMS) and mass spectrometry (MS) are especially suitable to this aim since they provide response times in the ms - s range. Moreover, as complementary methods they provide comprehensive information about the molecule and it's structure. The aim of the work is to qualitatively interrogate the sample composition of a photocatalytically initiated thiol-ene coupling in real time. This contribution presents primary results of direct analysis of the photoinitiated synthesis of methyl 2-((tert-butoxycarbonyl)amino)-3-((3-hydroxypropyl)thio) propanoate by IMS and MS utilizing different ionization sources. The thiol-ene reaction is performed between N-Boc-cysteine methyl ester and allyl alcohol utilizing Ru(bpz)3(PF6)2 catalyst as a photoinitiator and p-toluidine as a redox mediator, irradiated at 450 nm according to the procedure presented in [2]. The obtained results were validated by NMR analysis unambiguously indicating the formation of the newly formed C-S bond and additionally providing total reaction yield calibration curves for a quantitative analysis. T2 - ESCRE 2015 CY - München DA - 2015-10-27 PY - 2015 AN - OPUS4-34779 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wagner, Sabine A1 - Wan, Wei A1 - Biyikal, Mustafa A1 - Panne, Ulrich A1 - Rurack, Knut A1 - Carrasco, Sergio A1 - Moreno-Bondi, Maria C. T1 - Fluorescent Nanosensor based on Molecularly Imprinted Polymer for the Detection of Contaminants in Water N2 - As the interest in rapid and sensitive detection methods is growing, molecularly imprinted polymers (MIPs) are increasingly considered as an alternative to bio-macromolecular recognition units such as antibodies or enzymes due to their facilely tailorable selectivity towards certain analytes or a group of structurally related species. The low production costs, stability, robustness and format adaptability of MIPs combined with the possibility to imprint and thus their ability to recognize a wide variety of target analytes can be potentially useful in chemical sensor applications.[1] With regard to optical sensing technologies, however, MIPs have only been used in considerably few applications, especially in fluorescence sensors. This limitation is basically due to the fact that the incorporation of a fluorescently responding moiety into a polymer matrix is a challenge. One way to overcome this limitation is to use tailor-made fluorescent indicator monomers and thin MIP-shells on silica particles.[2] Here, we present silica sensor particles with a thin MIP layer which was grown onto the silica surface via reversible addition-fragmentation chain transfer (RAFT) polymerization. The homogeneous MIP shell contains fluorescent phenoxazine-urea monomers as signal generation elements. The carboxylate salts of the antibiotic ampicillin (AMPI) and the herbicide 2,4 dichlorophenoxyacetic acid (2,4-D) were used as templates in those studies. In this case, hydrogen bonds are formed between the urea group of the fluorescent monomer and the carboxylate group of the template. To investigate the binding behavior of the MIPs and the control non-imprinted polymer (NIP) particles in terms of discrimination and imprinting factor, titration experiments with AMPI and 2,4-D salts were performed directly in organic solution. In order to study the detection possibilities in aqueous solution, a simple phase-transfer assay using fluorescence spectroscopy was investigated for both analytes. T2 - Adlershofer Forschungsforum 2016 CY - Berlin, Germany DA - 2015-11-11 PY - 2015 AN - OPUS4-35238 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Michalik-Onichimowska, Aleksandra A1 - Riedel, Jens A1 - Panne, Ulrich A1 - Löhmannsröben, Hans-Gerd A1 - Beitz, Toralf T1 - The effect of laser pulse duration on atmospheric pressure IR-MALDI using liquid matrices N2 - Matrix assisted laser desorption/ionization using liquid matrices and infrared laser irradiation (liquid IR-MALDI) is an attractive detection scheme since it enables a direct coupling to liquid chromatographic separation techniques.1 Albeit extensive studies have been targeted to achieve a more general understanding of the underlying ionization mechanism, the exact role of individual contributions, such as thermal vaporization, phase explosion or photoablation, could not be exhaustively identified.2 This contribution will present a direct comparison of ion mobility (IM) spectra obtained by utilizing an optical parametric oscillator and an Er:YAG laser, both operating at a central wavelength of = 2.94 µm, but with temporal pulse widths of 7 ns or several hundred µs, respectively. Thus, the resulting peak power of the Er:YAG laser is three orders of magnitude smaller than that of the OPO, however supplies a tenfold higher energy per pulse. In addition to the mere detection efficiencies, analysis of the IM spectrometric results gives insights into the initial solvation state of the formed ions. Accompanying high speed shadowgraphy imaging experiments contribute towards a better understanding of the involved liquid-gas phase transition dynamics. T2 - Bunsentagung 2015 CY - Bochum DA - 2015-05-14 PY - 2015 AN - OPUS4-34777 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhang, Zhiyang A1 - Buurman, Merwe A1 - Panne, Ulrich A1 - Kneipp, Janina A1 - Merk, Verginia T1 - SERS characterization of photo-induced dimerization N2 - Dimercaptoazobenzene (DMAB) can be formed from different precursors (e.g., p-Nitrothiophenol and p-Aminothiophenol, see also examples in Figure) by a reaction that can be influenced by localized surface plasmons.[1] Many reaction parameters were shown to influence the pathway of DMAB formation. The mechanism of DMAB formation is studied by surface enhanced Raman scattering (SERS). It is very interesting to delineate effects due to properties of the reacting molecular species and those related to the plasmonic properties of the nanostructures. Currently, we achieve this e.g., by the comparison of the usage of nanoparticle solutions and immobilized nanoparticles.[2] We perform this work, since we aim at modifying and controlling the reaction conditions precisely in microscopic volumes, exploiting the multifunctional properties of different plasmonic nanoparticles [3]. In our poster, we will show and discuss SERS data obtained in experiments at varying reaction and excitation conditions. T2 - Molecular Plasmonics 2015 CY - Jena, Germany DA - 2015-05-07 PY - 2015 AN - OPUS4-34662 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hoffmann, Holger A1 - Knizia, Christian A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - An insight into fractionated environmental water samples to understand matrix effects in immunoassays N2 - N4-acetyl-SMX is the most important cross-reacting compound for the SMX-ELISA with concentrations of 1064 - 2488 ng/L in influent wastewater and 40 - 160 ng/L in effluent wastewater. The ELISAgrams for estrone show less interfering signals than for SMX. ELISAgrams of SMX and estrone display in effluent wastewater more interfering signals than in influent wastewater. T2 - ANAKON CY - Graz, Austria DA - 23.03.2015 KW - Estrone KW - LC-ELISA KW - Matrix effects KW - Sulfamethoxazole PY - 2015 AN - OPUS4-38533 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Haldorai, Y. A1 - Kharismadevi, D. A1 - Tuma, Dirk A1 - Shim, J.-J. T1 - Properties of chitosan/magnetite nanoparticles composites for efficient dye adsorption and antibacterial agent N2 - Chitosan (CS)/iron oxide (Fe3O4) composites were prepared using a chemical precipitation method. The CS/Fe3O4 composite was characterized by Fourier-transform infrared spectroscopy, X-ray diffraction, transmission electron microscopy, and zeta-potential measurements. The Composite was used to remove methyl orange (MO) dye from an aqueous solution. The factors affecting the adsorption capacity, such as adsorption time, absorbent dosage and solution pH were investigated. The results suggested that the composite was an effective adsorbent for the removal of MO dye from its aqueous solution. Kinetics studies showed that the adsorption process was consistent with a pseudo-second-order model. The adsorbent efficiency was unaltered, even after five cycles of reuse, and the adsorbent could be recollected easily using a magnet. In addition, the composite exhibited a superior antibacterial efficacy against Escherichia coli; 82 % within 24 h, as measured by the colony forming units. KW - Chitosan KW - Fe3O4 KW - Composite material KW - Adsorbent KW - Antibacterial agent PY - 2015 DO - https://doi.org/10.1007/s11814-014-0368-9 SN - 0256-1115 SN - 1975-7220 VL - 32 IS - 8 SP - 1688 EP - 1693 PB - Springer US CY - New York AN - OPUS4-35894 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hoffmann, Holger A1 - Knizia, Christian A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - An insight into fractionated environmental water samples to understand matrix effects in immunoassays N2 - N4-acetyl-SMX is the most important cross-reacting compound for the SMX-ELISA with concentrations of 1064 - 2488 ng/L in influent wastewater and 40 - 160 ng/L in effluent wastewater. The ELISAgrams for estrone show less interfering signals than for SMX. ELISAgrams of SMX and estrone display in effluent wastewater more interfering signals than in influent wastewater. T2 - ANAKON CY - Graz, Austria DA - 23.03.2016 KW - Sulfamethoxazole KW - Estrone KW - LC-ELISA KW - Matrix effects PY - 2015 AN - OPUS4-35792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hartmann, S. A1 - Shaporin, A. A1 - Hermann, S. A1 - Bonitz, J. A1 - Heggen, M. A1 - Meszmer, P. A1 - Sturm, Heinz A1 - Hölck, O. A1 - Blaudeck, T. A1 - Schulz, S. E. A1 - Mehner, J. A1 - Gessner, T. A1 - Wunderle, B. T1 - Towards nanoreliability of CNT-based sensor applications: Investigations of CNT-metal interfaces combining molecular dynamics simulations, advanced in situ experiments and analytics N2 - In this paper we present results of our recent efforts to understand the mechanical interface behaviour of single-walled carbon nanotubes (CNTs) embedded in metal matrices. We conducted experimental pull-out tests of CNTs embedded in Pd or Au and found Maximum forces in the range 10 - 102 nN. These values are in good agreement with forces obtained from molecular Dynamics simulations taking into account surface functional Groups (SFGs) covalently linked to the CNT material. The dominant failure mode in experiment is a CNT rupture, which can be explained with the presence of SFGs. To qualify the existence of SFGs on our used CNT material, we pursue investigations by means of fluorescence labeling of surface species in combination with Raman imaging. We also report of a tensile test system to perform pull-out tests inside a transmission electron microscope to obtain in situ images of CNT-metal interfaces under mechanical loads at the atomic scale. T2 - 2015 16th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems CY - Budapest, Hungary DA - 20.4.2015 KW - Carbon nanotube CNT KW - Metal matrix KW - Pull-out test KW - Molecular dynamics simulation KW - Surface functional groups KW - Fluorescence labeling KW - Raman imaging KW - Tensile test inside a TEM PY - 2015 SN - 978-1-4799-9950-7 VL - 2015 SP - 1 EP - 8 PB - IEEE AN - OPUS4-37625 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Bandow, Nicole T1 - HORECA, Hochwertiges Recycling von Aschen aus der Müllverbrennung mittels eines innovativen Nassaufbereitungsverfahrens für eine ressourcenschonende und umweltverträgliche Verwertung N2 - Hausmüllverbrennungsasche (HMVA) hinsichtlich der Menge und der Qualität generierter Fraktionen optimiert. Die Optimierung wurde vom Projektpartner Evers und Co. GmbH durchgeführt. Neben der für die Wirtschaftlichkeit relevanten Rückgewinnung von Metallen stand die Qualität der mineralischen Fraktionen im Vordergrund. Die Mineralik stellt mengenmäßig den größten Anteil an HMVA dar und sollte weitestgehend für einen möglichen Einsatz als Baustoff nutzbar gemacht werden. Dafür musste insbesondere der Chlorid- und Sulfatgehalt reduziert werden. Gut wasserlösliche Substanzen können durch die nass-mechanische Aufbereitung über das Prozesswasser ausgetragen und unerwünschte Elemente im Filterkuchen angereichert und entsorgt werden. KW - Rostasche KW - Nassaufbereitung PY - 2015 VL - KF2201051MF2 SP - 1 EP - 34 AN - OPUS4-52424 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Beck, Uwe T1 - Abschlussbericht zum BMWi / MNPQ – Verbundprojekt Quo Vadis Qualitätssicherung von Verbundwerkstoffen und Validierung des Zentrifugenversuchs – eines neuartigen Prüfverfahrens zur Bestimmung von Verbundfestigkeiten N2 - Quo Vadis – Kurzdarstellung Im Fokus von Quo Vadis stehen die Qualitätssicherung von Verbundwerkstoffen und die Validierung der Zentrifugentechnologie zur quantitativen Bestimmung von Festigkeitswerten in der Beanspruchung auf Zug als Mehr-Proben-Prüfverfahren unter Verwendung einer analytischen Zentrifuge (nachfolgend als „Adhesion Analyser LUMiFrac®“ bezeichnet). Zu den Festigkeiten, die mit Hilfe des LUMiFrac® unter Verwendung aufgeklebter Prüfstempel bestimmt werden, gehören die Fügefestigkeit (FF) von Klebverbindungen, die Haftfestigkeit (HF) von Beschichtungen sowie die Verbundfestigkeit (VF) von Faserverbundwerkstoffen. Aufbauend auf zwei Funktionsmustern der analytischen Zentrifuge sollen für die genannten Anwendungsszenarien (FF, HF, VF) in Anlehnung an die geltenden Normen DIN EN 15870 „Klebstoffe – Zugprüfung zur Bestimmung der Zugfestigkeit von Stumpfklebungen“ und DIN EN ISO 4624 „Beschichtungsstoffe – Abreißversuch zur Beurteilung der Haftfestigkeit“ geeignete Prüfstrategien und -abläufe sowie zum Klebprozess kompatible Aufnahmen für den Prüfkörperverbund in der Zentrifuge entwickelt werden. Im Ergebnis des Vorhabens soll ein automatisiertes und validiertes Mehr-Proben-Prüfverfahren zur Qualitätssicherung von Verbundfestigkeiten zur Verfügung stehen, welches neben der Hardware auch eine Software für die angepassten Prüfstrategien in Form von SOPs (standard operating procedures) bereitstellt. KW - Zentrifugentechnologie KW - Mehr-Proben-Prüfverfahren KW - Fügefestigkeit KW - Klebverbindungen KW - Haftfestigkeit KW - Beschichtungen KW - Verbundfestigkeit KW - Zugfestigkeit PY - 2015 N1 - Das Dokument unterliegt der Vertraulichkeit und kann nicht zugänglich gemacht werden Projektlaufzeit: 01.05.2012 bis 31.08.2015 The document is subject to confidentiality restrictions and cannot be made accessible Project runtime: 01.05.2012 bis 31.08.2015 SP - 1 EP - 12 AN - OPUS4-50390 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schwaar, Timm T1 - Entwicklung von multidimensionalen Hochdurchsatzmethoden zur Analyse von partikelbasierten Peptidbibliotheken N2 - Ziel dieser Arbeit war die Entwicklung einer Methode zur Hochdurchsatzanalyse von partikelgebundenen Split-and-Mix-Peptidbibliotheken. Dabei wurde ein System entwickelt, das Partikelbibliotheken in kurzer Zeit auf ihre Bindung zu einem Zielmolekül hin untersucht und im nächsten Schritt eine direkte „Ein-Partikel“-Sequenzierung der Peptide von der festen Phase ermöglicht. Die Analyse der Bindung eines Zielmoleküls an ein selektiv bindendes Peptid wurde dabei in einem Modellsystem simuliert. Dazu wurde FITC-markiertes Neutravidin 3 mit festphasengebundenen biotinylierten und nicht-biotinylierten Peptiden inkubiert. Die Bindung von Neutravidin-FITC an die biotinylierten Peptide konnte erfolgreich mittels eines Fluoreszenzmikroskops nachgewiesen werden, wobei diese Methode für eine Hochdurchsatzanalyse ungeeignet war. So wurde die Analyse des Fluoreszenzassays auf einen Microarrayscanner übertragen (siehe Abbildung 33). Dies gelang erfolgreich wobei die hohe Eigenfluoreszenz des Tentagel-Harzes zu falsch positiven Ergebnissen führte. Mit einem Wechsel zum längerwelligen Fluoreszenzfarbstoff ATTO-633 konnten falsch positive Ergebnisse vermieden werden. Somit wurde die zeitintensive Fluoreszenzanalyse von einem Fluoreszenzmikroskop erfolgreich auf einen Microarrayscanner übertragen, welcher in kurzer Zeit (ca. 5 min pro Objektträger) eine Vielzahl an peptidbeladenen Partikeln gleichzeitig analysieren kann. KW - Peptide KW - OBOC library KW - MALDI-TOF-MS KW - Sequencing KW - Ladder sequencing KW - Solid-phase peptide synthesis KW - SPPS KW - Microarray KW - Fluorescence label KW - Polymer beads KW - Tentagel KW - Merrifield KW - Split and mix technology PY - 2015 SP - 1 EP - 80 PB - Humboldt-Universität zu Berlin CY - Berlin AN - OPUS4-54644 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kurth, Lutz T1 - Flame projectors for shof effects-Investigations of thermal radiation for assessing safety distances N2 - The use of flames as part of shows is state of the art. Besides pyrotechnic flame projectors, the use of projectors that produce flames by burning various gases, liquids and dusts is significantly increasing. In this study infrared radiation in the wavelength range from 7.5 to 14 microns was measured for several systems (flame projectors) and set in relation to known human pain threshold levels. From this relation safety distances been determined for a static scenario (audience watching show) and compared with those of approved pyrotechnic articles. KW - Safety distance KW - Thermal radiation KW - Flame projector PY - 2015 SN - 1082-3999 VL - 2015 IS - 34 SP - 31 EP - 36 PB - Journal of Pyrotechnics Inc. CY - Whitewater, CO 81527 USA AN - OPUS4-50054 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schaupp, Thomas A1 - Burger, S. A1 - Kannengießer, Thomas A1 - Zinke, M. A1 - Jüttner, S. T1 - Berichterstattung zum laufenden Projekt: „Ermittlung geeigneter Wärmeführungen zur Wasserstoffreduktion beim Schweißen höherfester Feinkornbaustähle mit modifiziertem Sprühlichtbogen“ N2 - Dieses Dokument fasst den Projekfortschritt des BAM-Projektes "Ermittlung geeigneter Wärmeführungen zur Wasserstoffreduktion beim Schweißen höherfester Feinkornbaustähle mit modifiziertem Sprühlichtbogen" im Rahmen des Fachausschusses 1 "Schweißmetallurgie & Werkstoffverhalten" des DVS e. V. zusammen. T2 - Sitzung des Fachausschusses 01 "Schweißmetallurgie & Werkstoffverhalten" der Forschungsvereinigung Schweißen und verwandte Verfahren des DVS e. V. CY - Aachen, DA - 27.10.2015 KW - Hochfester Feinkornbaustahl KW - Wasserstoff KW - MAG-Schweißen PY - 2015 AN - OPUS4-53668 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Beck, Uwe A1 - Baier, Jennifa A1 - Dähne, L. A1 - Lerche, K.-H. T1 - Schlussbericht zum BMWi/MNPQ-Verbundprojekt: PLASMA-FIT (PLASMA-kompatible Partikel zur gepulsten in-situ Injektion von ex-situ hergestellten Partikeln für add-on Funktionen und zur Identifizierung in BeschichTungen) N2 - Im Fokus steht die Qualitätssicherung mit Blick auf Herstellung, Modifizierung, Handling und Erprobung von PLASMA-kompatiblen Partikeln zur gepulsten in-situ Injektion von ex-situ hergestellten Partikeln für add-on Funktionen in und zur Identifikationsprüfung von BeschichTungen (PLASMA-FIT). Im Kern war zunächst zu prüfen, welche Klassen ex-situ hergestellter Partikel unterschiedlichster Materialien überhaupt bzw. unter welchen Bedingungen PLASMA-fit sind oder unter welchen Randbedingungen PLASMA-fit gemacht werden können. In den dazugehörenden Projektphasen Screening und Adaption stand dabei das komplexe Beanspruchungsszenario bestehend aus Vakuum-, Temperatur- und wenigstens kurzzeitiger Plasmabeständigkeit der ex-situ bereitgestellten Partikel im Fokus. In der Projektphase Applikation sollte dann unter Verwendung einer modifizierten Plasmaquelle (BAM-Patentanmeldung, beabsichtigte Lizenznahme durch Fa. CemeCon, Optionsvertrag) hinsichtlich der Realisierbarkeit, Prüfung und Qualitätssicherung von Plasmadispersionsschichten ein erster Praxistest zur in-situ Injektion von Partikeln in einen laufenden Beschichtungsprozess, zur Realisierung funktioneller Eigenschaften z.B. zur Identifikation oder Authentifizierung von Originalteilen, vorgenommen werden KW - Plasma-kompatible Partikel KW - Plasma-Injektion KW - add-on Funktionen PY - 2015 N1 - Das Dokument unterliegt der Vertraulichkeit und kann nicht zugänglich gemacht werden - The document is subject to confidentiality restrictions and cannot be made accessible - Projektlaufzeit: 17.11.2010-16.02.2015 - Project runtime: 17.11.2010-16.02.2015 SP - 1 EP - 10 AN - OPUS4-48360 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -