TY - CONF A1 - Braun, Ulrike A1 - Klöckner, P. A1 - Wagner, S. A1 - Ruhl, A.S. A1 - Eisentraut, P. A1 - Albrecht, M. A1 - Reemtsma, T. T1 - Determination of tire wear particles based on elemental composition N2 - In this presentation the use of ICP-MS for the analysis of tire wear particles in environmental samples is presented. T2 - Wassertagung der GdCh CY - Papenburg, Germany DA - 07.05.2018 KW - ICP-MS KW - Mikroplastik KW - Analytik KW - Reifenabrieb PY - 2018 AN - OPUS4-45201 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eitzen, L. A1 - Sartoretto, A. A1 - Braun, Ulrike A1 - Jekel, M. A1 - Ruhl, A.S. T1 - Einfluss von Dispergiermitteln auf Polystyrol- Mikroplastikdispersionen N2 - Es wird Herstellung definierter Dispersionen mit Partikeln aus Polystyrol (PS) zur beschrieben:für die Simulation natürlicher Stabilisierung, die Untersuchung des Partikelverhaltens und die effizienteren Klassierung der Partikel durch Filtration. T2 - Wasser Tagung der GdCh CY - Papenburg, Germany DA - 07.05.2018 KW - Mikroplastik KW - Analytik KW - Modellmaterialien PY - 2018 AN - OPUS4-45032 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, Ulrike A1 - Eisentraut, Paul T1 - Mikroplastik als analytische Herausforderung N2 - Der Vortrag beschäftigt sich mit den gängisten Methoden zur Probennahme, -vorbereitung und Detektion von Mikroplastik. Das Zusammenspiel von Fragestellung und Methode wird betont. Es wird auf das Dikussionspapier Analytik des BMBF-Forschungsschwerpunktes Plastik in der Umwelt besonders hingewiesen sowie Bemühungen zur Normierung der Methoden auf deutscher und internationaler Ebene dargestellt. T2 - 18. BfR-Forum Verbraucherschutz: Mikroplastik CY - Berlin, Germany DA - 06.06.2019 KW - Mikroplastik KW - Analyse KW - Normung PY - 2019 AN - OPUS4-48234 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul A1 - Goedecke, Caroline A1 - Dümichen, E. A1 - Kittner, Maria A1 - Hassanein, Yosri A1 - Jekel, M. A1 - Braun, Ulrike T1 - Ein µ zurück, zwei voran: Komplikationen bei der Mikroplastikdetektion per TED-GC-MS N2 - Die ThermoExtraktionDesorption-Gaschromatografie-Massenspektrometrie (TED-GC-MS) ist die wichtigste Methode der BAM zur Analyse von Mikroplastikpartikeln in Umweltproben. Mit wachsendem Erfahrungsschatz traten Komplikationen auf, bei deren Bewältigung das Analysensystem verbessert werden konnte. Das Poster präsentiert u. a. die Verbesserung der Nachweisgrenzen sowie die Eliminierung von Kontaminationsquellen aus gängigen Probennahmeverfahren. T2 - Tagung der Wasserchemischen Gesellschaft CY - Erfurt, Germany DA - 27.05.2019 KW - Mikroplastik KW - ThermoExtraktionDesorptionGCMS KW - Komplikation PY - 2019 AN - OPUS4-48235 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul A1 - Goedecke, Caroline A1 - Dümichen, E. A1 - Braun, Ulrike T1 - Detektion von Mikroplastik mittels Thermoextraktion Desorption Gas Chromatographie Massen Spektrometrie (TED-GC-MS) N2 - Das Poster gibt eine kurze Einleitung in die Thematik Mikroplastik in der Umwelt. Das Funktionsprinzip des Verfahrens und einige Kenndaten werden dargestellt. Optimierte Verfahrensparameter werden aufgezählt und Teilergebnisse aus zwei Messkampagnen gezeigt. T2 - Abschlusskonferenz BMBF-Projekt MiWa CY - Karlsruhe, Germany DA - 09.09.2019 KW - Mikroplastik KW - TED-GC-MS KW - Optimierung PY - 2019 AN - OPUS4-49117 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul A1 - Dümichen, E. A1 - Goedecke, Caroline A1 - Braun, Ulrike T1 - Mikroplastik-Bestimmung mit TED-GC-MS N2 - Der Vortrag beschreibt den Entwicklungsprozess des Analysenverfahrens TED-GC-MS zur Bestimmung von Mikroplastikgehalten in Umweltproben im Rahmen des BMBF-Projektes MiWa. Die Funktionsweise, die Automatisierung und die Optimierung einzelner Geräteparameter und Leistungsdaten werden gezeigt. Untersuchungen des Einflusses von Probenmatrices werden dargestellt und die Ergebnisse einiger Messkampagnen und Ringversuche vorgestellt, die die Routinefähigkeit des Verfahrens dokumentieren. T2 - MiWa-Abschlusskonferenz CY - Karlsruhe, Germany DA - 10.09.2019 KW - Mikroplastik KW - Thermoanalyse KW - TED-GC-MS PY - 2019 AN - OPUS4-49115 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisentraut, Paul A1 - Braun, Ulrike A1 - Dümichen, Erik T1 - Analyse von Mikroplastik Partikeln aus Umweltproben mit der TED-GC-MS N2 - Die weltweite Produktion von synthetischen Kunststoffen steigt stetig und ein Teil gelangt in die Umwelt. Die Kunststofffragmente werden durch Umwelteinflüsse zerkleinert und bilden schließlich Mikroplastik, dessen Gefährdungspotential intensiv diskutiert wird. Zur Beobachtung und Bewertung der Situation ist eine leistungsstarke und schnelle Analytik erforderlich, jedoch existieren noch keine harmonisierten Verfahren. Die ThermoExtraktionDesorption-GasChromatograpie-MassenSpektrometrie (TED-GC-MS) nutzt polymer-spezifische Zersetzungsprodukte und bietet durch ihre Schnelligkeit und Robustheit Vorteile gegenüber anderen Verfahren. T2 - Tagung der Wasserchemischen Gesellschaft 2017 CY - Donaueschingen, Germany DA - 22.05.2017 KW - Mikroplastik KW - Thermoanalytik KW - TED-GC-MS PY - 2017 AN - OPUS4-40452 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, Ulrike A1 - Dümichen, Erik A1 - Eisentraut, Paul T1 - Schneller Nachweis von Mikroplastik Partikeln in Umweltproben mit TED-GC-MS N2 - Der Vortrag stellt die neue entwickelte Analyse "TED-GC-MS" vor im Zusammenhang mit der Anwendung zur Mikroplastik Detektion. T2 - Gerstel Anwendertreffen CY - Mülheim/Ruhr, Germany DA - 05.10.2017 KW - Thermische Analyse KW - Mikroplastik KW - Analytik KW - GC-MS PY - 2017 AN - OPUS4-42415 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mueller, Axel A1 - Eisentraut, Paul A1 - Braun, Ulrike T1 - Nachweis von Mikroplastik in terrestrischen Umweltproben mittels TED-GC-MS N2 - Das Auftreten von Mikroplastik (MP) in aquatischen Ökosystemen ist bereits vielfältig dokumentiert. MP sind Kunststoffpartikel mit einer Größe kleiner als 5000 µm. Sie gelangen entweder als primäres MP (bspw. Zusätze in Kosmetikartikeln) oder als sekundäres MP (Fragmentierung größerer Kunststoffteile) in die Umwelt. Über die Existenz von Kunststoffpartikeln und deren Verbleib in terrestrischen Systemen ist wenig bekannt. Bis heute ist es unklar, ob MP im Boden durch Bodenerosion in die aquatische Umwelt transportiert wird und Boden somit als MP-Quelle für Gewässer fungiert, oder ob Partikel im Boden zurückgehalten werden und Boden eine MP-Senke darstellt. Hierzu sind aussagekräftige Messungen von Proben notwendig. Das Fehlen harmonisierter Verfahren für die Probenahme, Probenaufbereitung und Detektion erschwert die aktuelle Diskussion. In den wenigen bisher veröffentlichten Studien fanden hauptsächlich spektroskopische Methoden wie FTIR- oder Raman-Mikroskopie als Detektionsverfahren Anwendung. Diese liefern in der Regel Aussagen über Partikelanzahlen. Im vorliegenden Projekt soll als Analysemethode die von uns entwickelte ThermoExtraktionDesorption-GasChromatograpie-MassenSpektrometrie (TED-GC-MS) genutzt werden. Bei dieser Methode wird die Probe bis 600 °C erhitzt; die Zersetzungsgase werden auf einer Festphase sorbiert, anschließend in ein GS-MS-System überführt und dort desorbiert, getrennt und identifiziert. Die Methode erlaubt auf schnellem Wege über den Nachweis von spezifischen Zersetzungsprodukten die Identifikation einzelner Polymere, aber auch die quantitative Bestimmung des MP-Massegehaltes in einer Bodenprobe. Ziel des vorliegenden Projektes ist die Entwicklung eines systematischen Protokolls zur Probenahme, Probenaufarbeitung und anschließenden Analyse mittels TED-GC-MS von MP in terrestrischen Proben. Neben der Erstellung einer systematischen Probenahmestrategie sind Probenaufarbeitungsschritte wie die Reduktion der anorganischen Matrix mittels Dichteseparation sowie die oxidative Zersetzung organischer Matrixbestandteile notwendig. Im vorliegenden Tagungsbeitrag präsentieren wir die Anwendung der TED-GC-MS für die Bestimmung von MP in verschiedenen terrestrischen Umweltmatrizen. T2 - Umwelt 2018 CY - Münster, Germany DA - 09.09.2018 KW - TED-GC-MS KW - Mikroplastik KW - Analytik PY - 2018 AN - OPUS4-46364 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Deußing, G. A1 - Dümichen, Erik A1 - Braun, Ulrike T1 - Polymeranalytik Intelligent kombiniert N2 - Durch die intelligente Anbindung an die Stir Bar Sorptive Extraction (SBSE) lassen sich Zersetzungsprodukte der thermogravimetrischen Analyse (TGA) von Polymeren auf effiziente Weise anreichern, auftrennen und mittels GC/MS identifizieren. KW - Thermische Degradation KW - Mikroplastik PY - 2016 UR - http://www.gerstel.cn/de/GA51_Polymeranalytik.htm IS - 51 SP - 9 EP - 11 PB - Gerstel AN - OPUS4-42146 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dümichen, Erik A1 - Eisentraut, Paul A1 - Braun, Ulrike T1 - Polymere und Mikroplastik in der Umwelt N2 - Es wird ein neues und voll automatisiertes Verfahren vorgestellt für die Analyse von Mikroplastik in der Umwelt. KW - Mikroplastik KW - TED PY - 2017 SN - 0016-3538 VL - 61 IS - 9 SP - 24 EP - 27 PB - Wiley AN - OPUS4-42170 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Andrea A1 - Heilmann, M. T. A1 - Schmid, Thomas A1 - Maiwald, Michael T1 - Multivariate classification of Raman spectra from synthetic polymers – an approach for the improved detection of microplastics N2 - The increasing pollution of terrestrial and aquatic ecosystems with plastic debris, which leads to the accumulation of microscopic plastic particles of still unknown fate, is an upcoming problem of our time. In order to monitor the degree of contamination and to understand the underlying processes of degradation and internalization of plastic debris, analytical methods are urgently needed, which help to identify and quantify microplastics. Currently, expensive collected and purified materials enriched on filters are investigated by (micro) infrared spectroscopy (FTIR). Few studies using micro-Raman spectroscopy have been published as well. In contrast to FTIR, Raman spectroscopy can handle wet samples, but it suffers from interference of fluorescent materials. Both micro-FTIR- and micro-Raman, always include time consuming scanning and mapping procedures followed by the manual inspection and measurement of selected particles. T2 - 11. Kolloquium Arbeitskreis Prozessanalytik CY - Wien, Austria DA - 30.11.2015 KW - Prozessanalytik KW - Microplastics KW - Mikroplastik KW - Raman-Spektroskopie KW - Polymers KW - Multivariate classification PY - 2015 SP - 80 EP - 81 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38847 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kittner, Maria A1 - Altmann, Korinna A1 - Hamann, Sven A1 - Weyer, Rüdiger A1 - Kalbe, Ute T1 - Assessment of Microplastic Emissions from Artificial Turf Sports Pitches N2 - Following the recommendation of the European Chemicals Agency, on 25 September 2023 the European Commission passed a comprehensive new regulation to reduce emissions of microplastics (MP) into the environment, which includes the sale and use of intentionally added MP.1,2 This also applies to the application of synthetic rubber granulate infill in artificial turf systems and will ultimately have an impact on recreational sports. In Germany, rubber granulate made of ethylene-propylene-diene-monomer rubber (EPDM) is currently predominantly used. So far, there is no sufficient database for estimating MP emissions from artificial turf pitches into the environment and thus their relevance as a source of MP pollution.3 This topic is controversially discussed due to the complexity of sampling and analytics. To close this research gap, this project has the goal to determine mass balances for the emissions of MP from artificial turf pitches to allow an estimation of the amount of MP released per artificial turf pitch and year. Within this study, MP emissions of three artificial turf scenarios at different time states (unaged, artificially aged and real-time aged) are compared: the past (old turf: fossil based, synthetic infill), present (most commonly installed in Europe: fossil based, EPDM infill), and the future (turf with recycled gras fibres, no synthetic infill). To simulate the outdoor weathering during the lifespan of an artificial turf of approx. 15 years, brand-new artificial turf and EPDM rubber granulate were accelerated aged by means of UV weathering and mechanical stress. Potential MP emissions into surface and groundwater are simulated by lysimeter and shake experiments. MP mass contents are subsequently determined by Thermal Extraction Desorption Gas Chromatography/Mass Spectrometry. Using special microfilter crucibles allows the estimation of the particle sizes of the emitted MP, which is a fundamental requirement for an assessment of potential health hazards for humans. T2 - SETAC 2024 CY - Seville, Spain DA - 05.05.2024 KW - Mikroplastik KW - TED-GC/MS KW - Lysimeter KW - PAK KW - Schwermetalle PY - 2024 AN - OPUS4-60014 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kittner, Maria A1 - Altmann, Korinna A1 - Kalbe, Ute A1 - Hamann, S. A1 - Weyer, R. T1 - Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis N2 - Projektvorstellung "Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis": Motivation, Konzept, Umsetzung, erste analytische Ergebnisse der TED-GC/MS T2 - 24. Projekttage der Zukunft Bau Forschungsförderung CY - Bonn, Germany DA - 13.06.2023 KW - Mikroplastik KW - TED-GC/MS KW - Kunststoffrasen KW - Lysimeter KW - Beschleunigte Alterung PY - 2023 AN - OPUS4-58441 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Altmann, Korinna A1 - Abusafia, A A1 - Bannick, C-G A1 - Braun, U A1 - Crasselt, Claudia A1 - Dittmar, S A1 - Fuchs, M A1 - Gehde, M A1 - Hagendorf, C A1 - Heller, C A1 - Herper, D A1 - Heymann, S A1 - Kerndorff, A A1 - Knefel, M A1 - Jekel, M A1 - Lelonek, M A1 - Lunkenbein, T A1 - Obermaier, N A1 - Manhart, M A1 - Meurer, Maren A1 - Miclea, P-T A1 - Paul, A A1 - Richter, S A1 - Ricking, M A1 - Rohner, C A1 - Ruhl, A A1 - Sakai, Y A1 - Saravia Arzabe, C A1 - Scheid, C A1 - Schmitt, M A1 - Schnarr, M A1 - Schwertfirm, F A1 - Steinmetz, H A1 - Wander, Lukas A1 - Wiesner, Yosri A1 - Zechmeister, L T1 - RUSEKU - Repräsentative Untersuchungsstrategien für ein integratives Systemverständnis von spezifischen Einträgen von Kunststoffen in die Umwelt : Abschlussbericht N2 - Im Verbundprojekt RUSEKU wurde die Probenahme von Wasserproben entscheidend weiterentwickelt. Wichtig ist hierbei zu gewährleisten, dass genügend Merkmalsträger in jeder Probe untersucht werden. Es muss daher eine für den Probenahmeort repräsentative Beprobung hinsichtlich des Wasservolumens in Abhängigkeit der Partikelanzahl gewährleistet sein. Das Hauptaugenmerk lag im vorliegenden Projekt auf einer praxisnahen Beprobungsstrategie. Es wurden verschiedene Konzepte ausprobiert. • Grundsätzlich hat sich gezeigt, dass eine Stichprobe eine Momentaufnahme des MP-Massengehaltes zeigt. Es wird eine hohe Statistik, also eine Vielzahl an Messungen am gleichen Probenahmeort, benötigt, um eine valide Aussage über den MP-Gehalt zu machen. • Es zeigt sich, dass eine integrale Probenahme über mehrere Wochen mit dem SK routinemäßig möglich ist. Die erfassten MP-Massen sind reproduzierbar und robust. • Die DFZ ist für Stichproben geeignet. Partikel < 50 µm werden eventuell unterschätzt • Die fraktionierte Filtration kann für Stich- und Mischproben direkt im Feld genutzt werden. Fraktionen von 10 und 5 µm werden später im Labor Vakuum filtriert. Es erfolgt eine Fraktionierung der Probe mit Siebmaschenweiten von 1000, 500, 100, 50, 10 und 5 µm. • Die fraktionierte Filtration kann auch anschließend an die Beprobung mit dem SK zur Anwendung kommen. Wird die mit dem SK gewonnene Wasserprobe fraktioniert filtriert, kann neben einem MP-Gesamtgehalt auch eine Einschätzung über die Partikelgrößen gewonnen werden. • Für Wässer mit geringen Partikelzahlen wurde ein Messfiltertiegel entwickelt. Dieser hat eine Maschenweite von 6 µm. Seine Anwendung kann mögliche Verluste beim Transferieren vom Probenahmetool zum Messgefäß und mögliche Kontaminationen reduzieren. Die Optimierung der Probenahmestrategie wurde durch Modellversuche und Simulationen unterstützt. Modellversuche zum Sinkverhalten und Simulationen von MP in realen Gewässern verdeutlichten das komplexe Verhalten der Partikel. Es konnte gezeigt werden, dass Partikel ab einer bestimmten Größe (und kleiner) bei genügend starker Turbulenz sich in der Wassersäule unabhängig von ihrer Dichte verhalten und so auch MP mit kleiner Dichte (z.B. PE) in der gesamten Wassersäule zu finden sind. Es konnte mit dem TEM die Existenz von NP gezeigt werden. Ein wesentlicher Aspekt des RUSEKU Projektes war die Beprobung realer Kompartimente. Beprobt wurde neben Oberflächengewässern, das urbane Abwassersystem der Stadt Kaiserslautern, Waschmaschinenabwasser und Flaschenwasser. • In Oberflächengewässern wurde hauptsächlich PE gefunden. Je nach Probe und Gewässer konnten auch PP, PS, PET, PA, SBR und Acrylate nachgewiesen werden. • Im urbanen Abwassersystem der Stadt Kaiserslautern konnte an allen Probenahmestandorten MP nachgewiesen werden. Es wurde hauptsächlich PE, neben geringeren Mengen an PP, PS und SBR gefunden. Nach einem Regenereignis war der SBR Anteil deutlich erhöht. • Die Beprobung eines realen Wäschepostens, bestehend aus T-Shirts und Hemden mit PA/CO oder PES/CO Mischgewebe, zeigte einen PA- und PES-Austrag im Waschwasser. Der überwiegende Teil der detektierten Fasern ist aber auf Baumwolle zurückzuführen. Reine gravimetrische Messungen zur Detektion von MP führen zu einer starken Überschätzung. • In Flaschenwasser (PET-Flaschen) konnte MP detektiert werden. PET wurde nur im stillen Mineralwasser, nicht in Mineralwasser mit Kohlensäure gefunden werden. Teilweise wurde auch das MP-Material des Verschlusses im Wasser detektiert. • Für Luftproben konnte ein Aufbau zur größenselektiven Beprobung getestet werden. Neben der Probenahme hat das Projekt auch gezeigt, dass die TED-GC/MS geeignet für die MP-Detektion im Routinebetrieb ist. Die TED-GC/MS konnte weiter optimiert werden. Es wurden MP-Massen bestimmt. Im Projekt wurden erste realitätsnahe Referenzmaterialien für die MP Detektion hergestellt. Die Herstellung von realitätsnahen Polymeren in ausreichender Homogenität und Menge hat sich als große Herausforderung herausgestellt. KW - Mikroplastik KW - Probennahme KW - TED-GC/MS KW - Fraktionierte Filtration KW - Mikroplastikreferenzmaterial PY - 2022 SP - 1 EP - 201 AN - OPUS4-57800 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Altmann, Korinna A1 - Braun, U. T1 - Determination of Microplastic Mass Content by Thermal Extraction Desorption Gas Chromatography– Mass Spectrometry N2 - The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods. Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction Desorption gas chromatography–mass spectrometry (TED-GC–MS). KW - Microplastics KW - Mikroplastik KW - TED-GC/MS KW - Microplastics analytic KW - Mikroplastik Massegehalt PY - 2021 VL - 17 IS - 3 SP - 2 EP - 7 PB - MultiMedia (UK) LLC CY - Cranbury AN - OPUS4-52570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Axel A1 - Braun, U A1 - Altmann, Korinna T1 - Representative sampling of roadside soil and determination of tire wear contents by TED-GC/MS N2 - The presentation describes microplastic findings from tyre wear near roads. Both the sampling and the analysis are presented. T2 - Mikroplastik Workshop der Hochschule Zittau CY - Online meeting DA - 25.11.2021 KW - Mikroplastik KW - Reifenabrieb KW - TED-GC/MS KW - Probennahme PY - 2021 AN - OPUS4-53831 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna A1 - Müller, A. A1 - Kittner, Maria A1 - Braun, U. T1 - Plastik in Böden: Mikroplastik-Ergebnisse N2 - In diesem Vortrag geht um die Vorstellung der Ergebnisse des UBA Projektes Plastik in Böden. Es werden Mikroplastik-Gehalte in verschiedenen Böden präsentiert. T2 - Fachgespräch "Plastik in Böden" CY - Online meeting DA - 28.03.2022 KW - Mikroplastik KW - Mikroplastik Böden KW - Mikroplastik-Analytik PY - 2022 AN - OPUS4-54648 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wander, Lukas A1 - Lommel, Lukas A1 - Braun, Ulrike A1 - Meyer, Klas A1 - Paul, Andrea T1 - Development of a Low-Cost Method for Quantifying Microplastics in Soils and Compost Using Near-Infrared Spectroscopy N2 - Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and highthroughput mass quantification of microplastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermoanalytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg. The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most compact NIR spectrometers available. KW - Mikroplastik KW - NIR KW - Sensor KW - Kompost KW - Multivariat PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-552605 DO - https://doi.org/10.1088/1361-6501/ac5e5f VL - 33 IS - 7 SP - 1 EP - 13 PB - IOP Publishing Ltd. CY - Bristol AN - OPUS4-55260 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiesner, Yosri A1 - Altmann, Korinna T1 - MIKROPLASTIK – von der Probenvorbereitung bis zur Analytik N2 - Der Vortrag beschreibt die Herausforderungen bei der Analyse von Mikroplastik inklusive Probennahme, Probenvorbereitung und Detektion. Es werden Ergebnisse aus dem BMBF-Projekt RUSEKU vorgestellt. T2 - LABO-Anwendertag CY - Online meeting DA - 23.11.2021 KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik PY - 2021 AN - OPUS4-53829 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -