TY - CONF A1 - Cuéllar, Pablo T1 - Deep foundations for offshore wind turbines - 2nd part: lateral behavior & advanced topics T1 - Cimentaciones profundas para aerogeneradores marinos. 2a parte: Comportamiento Lateral + Temática avanzada N2 - This presentation deals with the phenomenology and design of pile foundations for offshore wind turbines, and is divided into two lectures. The second lecture continues with the case of laterally loaded offshore piles, which bears most relevance for the case of the monopile foundations. Here again, a clear separation between physical reality and design methods is intended. Finally, the last part of the second lecture introduces several advanced topics which lie outside the classical design approaches, namely the hydromechanical coupling effects (i.e. the excess pore-pressure generation around the monopiles), the cyclic pile fatigue and the so-called pile setup (i.e. the time effects on the axial pile capacity). The relevance of the latter two topics is illustrated with experimental results from a field testing campaign on real large-scale piles. T2 - Masters course on Soil Mechanics and Geotechnical Engineering. Geotechnical Laboratory of CEDEX CY - Online meeting DA - 17.03.2023 KW - Pile foundations KW - Offshore wind turbines KW - Physical phenomenology KW - Design methods KW - Numerical modelling KW - Physical testing PY - 2023 AN - OPUS4-57178 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Befestigungsmittel im Bauwesen - Der richtige Werkstoff!? N2 - Die Anforderungen in verschiedenen Fachgebieten des Bauwesens an metallene Befestigungsmittels hinsichtlich des Korrosionsschutzes sind zum einen Abhängig von den verwendeten Werkstoffen und zum anderen von der Korrosivität in der jeweiligen Exposition. Hier wird ein Überblick über die gängigen Werkstoffe als auch Anwendung und Fehlerquellen verschafft T2 - Vorlesung TU-Berlin CY - Berlin, Germany DA - 05.07.2023 KW - Korrosion KW - Korrosionsschutz PY - 2023 AN - OPUS4-57882 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Mögliche Fehlerquellen in der Praxis N2 - Durch das alkalische Milieu des Porenwassers im Beton ist der Stahl normalerweise dauerhaft vor Korrosion geschützt. Unter ungünstigen Umgebungsbedingungen (Chlorideintrag, Carbonatisierung) kann die passive Deckschicht auf der Stahloberfläche zerstört werden. Der Korrosionsprozess ist initiiert. Die entstehenden Korrosionsprodukte werden zunächst vom Porengefüge des Betons aufgenommen, ohne dass es zu sichtbaren Schäden am Bauwerk führt. Im fortgeschrittenem Stadium der Korrosion können sich dann Risse und Abplatzungen bilden. Um notwendige Sanierungsmaßnahmen sowohl aus sicherheitstechnischen Gründen als auch aus wirtschaftlichen Erwägungen rechtzeitig einzuleiten, sind frühzeitige und weitestgehend zerstörungsfreie Prüfverfahren zur Ermittlung der aktuellen Korrosionswahrscheinlichkeit der Stahlbewehrung von großer Bedeutung. Deshalb finden Methoden und Verfahren zur laufenden bzw. regelmäßigen Korrosionsüberwachung von Stahlbetonbauwerken ständig größere Beachtung, sowohl im Bereich Forschung und Entwicklung als auch in der Praxis. Die elektrochemische Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Methode bei der Detektion von chloridinduzierter Korrosion zum Einsatz. Der Lehrgang vermittelt den Teilnehmenden in kompakter Form einen zusammenfassenden Überblick über die notwendigen Grundlagen zum Verständnis der Messmethode, der Vorbereitung und Durchführung der Messungen, der notwendigen Begleituntersuchungen sowie der Interpretation der gewonnenen Daten. Der erste Tag ist der theoretischen Ausbildung gewidmet, am zweiten Tag folgt dann die praktische Anwendung der Lerninhalte. Am dritten Tag folgt die Abnahme der praktischen und theoretischen Prüfung zur Erlangung des Sachkundenachweises. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen CY - Berlin, Germany DA - 24.04.2023 KW - Potentialfeldmessung KW - Korrosion PY - 2023 AN - OPUS4-57497 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krentel, Daniel T1 - Einsatz von Messtechnik bei Großversuchen N2 - Im Rahmen dieses Vortrags werden die Besonderheiten beim Einsatz von Messtechnik bei Versuchen im Groß- und Realmaßstab und unter Freifeldbedingungen dargestellt. Anhand des Themenfeldprojektes CoFi-ABV und der dort durchgeführten Versuchsreihen werden die Rand- und Rahmenbedingungen beim Durchführen der Experimente, Instrumentierung und Versuchsaufbau sowie beispielhafte Ergebnisse erläutert. T2 - Lehrveranstaltung "Experimentelle Methoden der Aerodynamik" an der TU Berlin CY - Berlin, Germany DA - 24.01.2023 KW - Alternative Antriebe KW - Behälterversagen KW - Fahrzeugbrand KW - Großversuch KW - Auswirkungsbetrachtung PY - 2023 AN - OPUS4-56951 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Brückenbauwerke aus Spannbeton - der Weg von der initiierung Wasserstoffinduzierter Spannungsrisskorrosion bis zum Bauwerksversagen N2 - Bei der Brücke Altstädter Bahnhof handelte es sich um eine große Spannbetonkonstruktion, die einen elementaren Ver­kehrsknotenpunkt in der Stadt Brandenburg an der Havel bil­dete. Entgegen üblichen Spannbetonkonstruktionen mit kleinen Bündelspanngliedern kamen beim Haupttragwerk in Längsrich­tung großformatige Spannblockspannglieder zum Einsatz. Im Fall der vorliegenden Brücke setzte sich das Spannglied aus 392 ovalen Einzeldrähten aus Hennigsdorfer Produktion zusam­men, welche als spannungsrisskorrosionsgefährdet gelten. Bei Bauwerkserkundungen wurde ein hoher Versprödungsgrad der Spannstähle festgestellt, sodass die Brücke am 19.05.2021 ge­sprengt werden musste. Zuvor traten im Bereich detektierter Spanndrahtbrüche von außen erkennbare Längsrisse in den Stegen anstatt von üblicherweise quer gerichteten Biegerissen an der gezogenen Randfaser auf. Die abweichende Schadens­äußerung im Falle einer Spannstahlschädigung brachte das Bundesministerium für Digitales und Verkehr (BMDV) dazu, weitergehende Untersuchungen durchzuführen. In Zusammen­arbeit mit dem Landesbetrieb Straßenwesen Brandenburg, der Hochschule für Technik und Wirtschaft Dresden sowie der Bundesanstalt für Materialforschung und ­prüfung (BAM) wur­den experimentelle Untersuchungen in­situ konzipiert und durchgeführt. Im Konkreten wurde an zwei Messstellen eine gezielte Schädigung des großformatigen Spannglieds vorge­nommen, um das zuvor vorgefundene Schadensbild nach­zuvoll ziehen und validieren zu können. Konzept, Ergebnisse aus den Untersuchungen und Erkenntnisse für gleichartig ausge­führte Bauwerke sind Gegenstand des ersten Beitrags (Teil 1). Der zweite Teil [1] wird sich im Schwerpunkt den verwendeten Messverfahren und Monitoringsystemen widmen, welche die Durchführung des Versuchs begleiteten. T2 - FKKS-Jahrestagung CY - Berlin, Germany DA - 06.07.2023 KW - Korrosion KW - Spannungsrisskorrosion KW - Spannstahl KW - Wasserstoff PY - 2023 AN - OPUS4-57885 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - Potential mapping at concrete structures N2 - Potentialmapping is an electrochemical measurement for the detection of active corroding reinforcement at concrete structures. T2 - NDT&E Workshop 2023 CY - Berlin, Germany DA - 23.06.2023 KW - Corrosion KW - Potentialfeldmessung PY - 2023 AN - OPUS4-57884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino T1 - DIN 4871 N2 - Normative Anforderungen an ZfP-Prüfpersonal für ZfPBau sind in der DIN 4871 definiert. Die Ausbildung von Prüfpersonal für Potentialfeldmessung soll gemäß Norm zweistufig erfolgen. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen CY - Berlin, Germany DA - 24.04.2023 KW - Potentialfeldmessung KW - Korrosion PY - 2023 AN - OPUS4-57498 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zekhnini, Khalid T1 - Corrosion behavior of simulated monopile foundation by S355J2 steel in artificial seawater and sediment N2 - The development of offshore wind turbines (WTGs) presents many challenges in terms of safe operation over extended periods of time. One of these is the corrosive environment towards metallic materials, which can lead to a loss of material thickness and thus to a deterioration of mechanical performances, especially the strength of infrastructures. This can be counteracted by painting and cathodic protection (CP). Much research has already been done in this area about inhibiting the corrosion process. However, gaps exist regarding free corrosion. This plays a greater role especially for time intervals during the installation of the systems and their maintenance, during which often no CP can be operated. This is especially true for areas where painting surfaces is impossible e.g., sediment areas. This problem is exacerbated by the different corrosion rates caused by the different zones (water and sediment), with their different amounts of dissolved oxygen. This presentation deals with experiments in artificial seawater and sediment. Classical S355J2 steel samples in the form of coupons were fitted with welding wires that carried out the electrical contact to the outer side of the basin. Inside the basins, the specimens are stored in different zones like water and sediment which should simulate the foundation situation of monopiles. The mass loss was determined gravimetrically, elemental currents between specimens in water and sediment were measured and electrochemical investigations were carried out. The influences of the zones, based on different solved oxygen contents, and the rolling skin towards the corrosion behavior of the mild steel samples were determined in this work. Especially the influence of the sediment showed unexpected behavior, determined by electrochemical investigations. These results allow better conclusions to be drawn about the corrosion behavior of low alloy steels in offshore environments used in sediment and seawater, which cannot always be protected. T2 - Eurocorr 2023 CY - Brussels, Belgium DA - 28.08.2023 KW - Marine Corrosion KW - Offshore KW - Monopile KW - Sediment KW - Artificial seawater PY - 2023 AN - OPUS4-58175 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino A1 - Lehmann, Jens T1 - Erörterung des Messprotokolls N2 - Durch das alkalische Milieu des Porenwassers im Beton ist der Stahl normalerweise dauerhaft vor Korrosion geschützt. Unter ungünstigen Umgebungsbedingungen (Chlorideintrag, Carbonatisierung) kann die passive Deckschicht auf der Stahloberfläche zerstört werden. Der Korrosionsprozess ist initiiert. Die entstehenden Korrosionsprodukte werden zunächst vom Porengefüge des Betons aufgenommen, ohne dass es zu sichtbaren Schäden am Bauwerk führt. Im fortgeschrittenem Stadium der Korrosion können sich dann Risse und Abplatzungen bilden. Um notwendige Sanierungsmaßnahmen sowohl aus sicherheitstechnischen Gründen als auch aus wirtschaftlichen Erwägungen rechtzeitig einzuleiten, sind frühzeitige und weitestgehend zerstörungsfreie Prüfverfahren zur Ermittlung der aktuellen Korrosionswahrscheinlichkeit der Stahlbewehrung von großer Bedeutung. Deshalb finden Methoden und Verfahren zur laufenden bzw. regelmäßigen Korrosionsüberwachung von Stahlbetonbauwerken ständig größere Beachtung, sowohl im Bereich Forschung und Entwicklung als auch in der Praxis. Die elektrochemische Potentialfeldmessung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszustandes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Methode bei der Detektion von chloridinduzierter Korrosion zum Einsatz. Der Lehrgang vermittelt den Teilnehmenden in kompakter Form einen zusammenfassenden Überblick über die notwendigen Grundlagen zum Verständnis der Messmethode, der Vorbereitung und Durchführung der Messungen, der notwendigen Begleituntersuchungen sowie der Interpretation der gewonnenen Daten. Der erste Tag ist der theoretischen Ausbildung gewidmet, am zweiten Tag folgt dann die praktische Anwendung der Lerninhalte. Am dritten Tag folgt die Abnahme der praktischen und theoretischen Prüfung zur Erlangung des Sachkundenachweises. T2 - Sachkundelehrgang zur Durchführung von Potentialfeldmessungen CY - Berlin, Germany DA - 24.04.2023 KW - Potentialfeldmessung KW - Korrosion PY - 2023 AN - OPUS4-57496 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ebell, Gino A1 - Burkert, Andreas T1 - Standortabhängige Dauerhaftigkeitsbetrachtungen von Zink unter atmosphärischer Korrosion N2 - In maritimer Exposition können Zinkbauteile Nutzungsdauern von 50 Jahren erreichen. Dabei werden Expositionen mit Spritzwasserbelastung durch Meerwasser nicht betrachtet. Normative Betrachtungen und Korrosionsprognosen basierend auf Einjahreswerten liefern hier grundlegend falsche Ergbnisse, da sie eine signifikant höhere Belastung der Atmosphäre mit SO2 voraussetzen. T2 - Korrosionsschutz in der maritimen Technik CY - Hamburg, Germany DA - 04.05.2023 KW - Korrosion KW - Feuerverzinkter Stahl PY - 2023 AN - OPUS4-57489 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -