TY - CONF A1 - Niederleithinger, Ernst T1 - Geophysical methods delivering input to geostatistical methods for geotechnical site characterization N2 - Geophysical methods are able to contribute significantly to geotechnical site characterization. In-situ parameters are collected and gaps between boreholes or other direct tests are filled with information. However the limited resolution has to be considered and the indirect geophysical parameters have to be translated into something geotechnically useful. Moreover, the limitations have to be evaluated when including geophysical data into geostatistical models. If done properly, the use of geophysics will help in an efficient and effective site characterization. A comprehensive overview on existing geophysical (mostly seismic) methods is given as well as information on the calibration of geophysical against geotechnical parameters, pitfalls and limitations and some hints how to include these data into geostatistical/geotechnical models. T2 - ICGoES International Conference on Geologicalk Engineering and Geosciences CY - Yogyakarta, Indonesia DA - 21.09.2022 KW - Geophysics KW - Geostatistics KW - Geotechnics PY - 2022 AN - OPUS4-55806 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Liao, Chun-Man A1 - Niederleithinger, Ernst T1 - Real time bridge monitoring using ultrasonic techniques combined with six component (6-c) measurements N2 - This study aims to develop a real-time monitoring method for the structural performance by ultrasonic testing in combination with six-component (6-C) translation and rotation measurements. So far, the recordings of the velocity and acceleration response in the translation direction have been used to obtain the eigenfrequencies of structures. Recently, measurement of rotation has been used to fully characterize the dynamic behavior of structures. In this research, 6-C sensors consisting of a three-component rotational seismometer and a three-component broadband seismometer are evaluated for their suitability for bridge monitoring. Since changes in environmental conditions such as temperature during vibration recordings affect the structural evaluation results, cross-correlation function is applied here to the 6-C ambient vibration signals to reconstruct the wave propagation on the one hand, and coda wave interferometry (CWI) is applied to obtain the internal velocity variation from waveforms on the other hand. In field tests on a large-scale prestressed concrete bridge model, it was verified whether the prestress loss can also be determined in presence of temperature effects. For this purpose, measurements were performed in two scales, ultrasonic and output-only vibration measurements. The change in structural properties due to the prestress loss should be detected by the pulse velocity change. The results demonstrate both the performance and advantages of ultrasonic techniques and the capabilities of 6-C sensors. Thus, the application of CWI to wave signals can contribute comprehensively to bridge monitoring. T2 - NDT-CE 2022 CY - Zurich, Switzerland DA - 16.08.2022 KW - 6-C vibration signals KW - Coda wave interferometry KW - Cross-correlation function KW - Prestressed bridge KW - Structural health monitoring KW - Ultrasonic PY - 2022 AN - OPUS4-55646 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas A1 - Fontoura Barroso, Daniel A1 - Hau, Julia A1 - Niederleithinger, Ernst ED - Cunha, A. ED - Caetano, E. T1 - Accounting for Long Term Environmental Influences on Ultrasonic Monitoring Measurements of Reinforced Concrete Constructions with Embedded Transducers N2 - Ultrasound measurements in concrete are a well-known technique in civil engineering and non-destructive testing. For consistent monitoring of a concrete structure, the common techniques, using external sensors can often not provide the appropriate degree of repeatability, as the surface of structures changes, and comparable coupling conditions cannot be guaranteed when a measurement is repeated after some time. By embedding ultrasound transducers in concrete, we aim to develop a strategy for long-term monitoring of infrastructure, especially bridges, as a supplement and extension to other techniques. Applying the so-called coda wave interferometry to these measurements we can detect subtle changes in the medium far beyond the Resolution limit of traditional time of flight methods. A smart sensor layout enables cost-efficient sensing of the entire area of interest. Embedding the transducers might remove uncertainties like coupling or positioning changes, while other challenges remain. Temperature and moisture content influence the structure and the transducers. These drifts need to be recorded and removed and good coupling must be ensured while not being able to visually inspect the sensor. In a multidisciplinary research group funded by the German Research Foundation, we aim to solve these problems on the way towards an ultrasound monitoring system for reinforced concrete structures. In various experiments in the lab and field, we determine the influence of temperature variations on the measurements and the equipment. As the monitoring task is the detection of irreversible damages - not reversible changes - a smart system requires a smart way of discrimination between permanent damages and reversible changes. With the data collected in these experiments, we present an approach to an environmental correction to ultrasound data to avoid a misinterpretation of these environmental changes as damage indicators. T2 - 10th International Conference on Structural Health Monitoring of Intelligent Infrastructure CY - Porto, Portugal DA - 30.06.2021 KW - Ultrasound KW - Coda Wave Interferometry (CWI) KW - Structural Health Monitoring KW - Embedded Sensors PY - 2021 SP - 1 EP - 7 AN - OPUS4-54007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Niederleithinger, Ernst ED - Meyendorf, N. ED - Ida, N. ED - Singh, R. ED - Vrana, J. T1 - NDE 4.0 in Civil Engineering N2 - Civil engineering industry is one of the most important industry sectors in the worldwide economy. It contributes significantly to the gross economic product and general employment. Even more important, it provides many of the basic needs of the society (e.g., housing, infrastructure, and protection from natural hazards). The concept of “Industry 4.0” or “Smart Production” has not yet made significant progress in the civil engineering industry. The designing, building, and operating processes are still widely dominated by the exchange of printed documents and drawings. Most objects (buildings and other constructions) are unique, and a large part of the production still requires a large amount of manual labor. As-built documentation and quality assurance are often neglected. Civil engineering is among the industry sectors with the lowest level of digitalization and the lowest gain in productivity. However, this is going to change. In the past decade, several drivers have challenged the ways clients, contractors, and authorities currently operate. These drivers include but are not limited to an increasing demand for serialization and automatization or the mandatory introduction of “Building Information Modeling” (BIM) in public procurement as well as the upcoming use of digital twins. NDE plays an increasing role in quality assurance, condition assessment, and monitoring of structures. However, with very few exceptions, applications are mostly nonstandardized and performed only at selected sites. To change this, the NDT-CE community including manufacturers, service providers, clients, and the scientific community must work consistently on open data formats, interfaces to BIM, standardization, and validated ways for a quantitative use of the results in the assessment of constructions. KW - NDE 4.0 KW - Civil engineering KW - BIM KW - IFC PY - 2021 SN - 978-3-030-48200-8 DO - https://doi.org/10.1007/978-3-030-48200-8 SP - 1 EP - 14 PB - Springer Nature CY - Cham, Switzerland AN - OPUS4-54161 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - NDT CE from simple detectors to deep insight and quantitative structural assessment N2 - Non-destructive testing methods are available in civil engineering for decades to estimate concrete properties or to detect flaws and features. But recently we have seen the dawn of next-generation tools, methods, and applications. Some of them will be discussed in the web talk: – Better tools: deeper and more detailed insight into concrete constructions – Better methods: Quantitative use in probabilistic structural assessment – Better rules: Towards standardization, qualification, and certification – Better application: Digitalization and Elimination of the boundaries between NDT, SHM, and BIM: NDT-CE 4.0 Not enough? I might show, how cosmic rays might become a game-changer in NDT-CE. This live webinar record was provided by https://eurostruct.org T2 - Eurostruct Live Talk CY - Online meeting DA - 12.05.2021 KW - NDT-CE KW - Concrete KW - Ultrasound KW - Muons PY - 2021 AN - OPUS4-54158 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Acoustic emission and ultrasonic monitoring of a prestressed concrete bridge in its final years N2 - Many European bridges built in the 1950s, 60s and 70s must be re-placed in the next decade due to structural deficiencies, insufficient load capacity or other issues. However, the existing bridges must be used for another couple of years even if flaws and damages already have been detected. In Germany, several prestressed concrete bridges have been instrumented with acoustic emission detection systems to detect wire breaks and to provide early warning signs before failure. To evaluate and interpret the consequences of wire breaks additional instrumentation and accompanying measures as finite element modeling are required. At a bridge in southern Germany we have complemented such a system with active ultrasonic monitoring. Repeated ultrasonic measurements are evaluated with a very sensible algorithm called coda wave interferometry. This method, inspired by seismology, has been shown to deliver early warning signs in lab experiments. Large volumes of concrete can be monitored with a limited network of ultrasonic transducers. We will report on the installation, capabilities, and lim-itations as well as first results. T2 - 1st Conference of the European Association on Quality Control of Bridges and Structures (Eurostruct) CY - Padua, Italy DA - 29.08.2021 KW - Bridge KW - Concrete KW - Acoustic emission KW - Ultrasound KW - Monitoring PY - 2021 AN - OPUS4-54160 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst A1 - Hille, Falk A1 - Hofmann, Detlev A1 - Kind, Thomas ED - Isecke, B. ED - Krieger, J. T1 - Überwachung der Brücke Altstädter Bahnhof, Brandenburg./H. Begleituntersuchungen mit moderner Sensorik und zerstörungsfreier Prüfung N2 - Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert. T2 - 5. Brückenkolloquium CY - Ostfildern, Germany DA - 06.09.2022 KW - Monitoring KW - Brücke KW - Radar KW - Vibration KW - Faseroptik PY - 2022 SN - 978-3-8169-3549-0 SP - 555 EP - 566 PB - Expert Verlag CY - Tübingen AN - OPUS4-55627 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Liao, Chun-Man A1 - Hicke, Konstantin A1 - Bernauer, F. A1 - Igel, H. A1 - Hadziioannou, C. A1 - Niederleithinger, Ernst ED - Isecke, B. ED - Krieger, J. T1 - Multi-Sensor measurements on a large-scale bridge model N2 - This contribution introduces an investigation of a large-scale prestressed concrete bridge model (“BLEIB” structure at the BAM-TTS open air test site) by means of on-site cooperative measurements. This bridge has an external post-tensioning system and has been instrumented with the ultrasonic transducers, temperature sensors and optical fibers for Distributed Acoustic Sensing (DAS). Our experiment was designed to test the suitability of the novel 6C sensors developed within the framework of the GIOTTO project – the IMU50. The IMU50 sensor enables vibration measurements in translation along three axes and rotation around three axes. The geophone sensors were considered for complementary measurements of vertical velocity response. In the experiment, several perturbations were achieved by controlling the external influence factors such as loading and prestressing changes. The aim of the integrated measurement strategy was to fully observe the results of the condition change and to verify the effectiveness of multiple sensors for bridge monitoring. T2 - 5. Brückenkolloquium CY - Ostfildern, Germany DA - 06.09.2022 KW - Concrete KW - Bridge KW - Monitoring KW - Rotation KW - Distributed acoustic sensing PY - 2022 SN - 978-3-8169-3549-0 SP - 223 EP - 230 PB - Expert Verlag CY - Tübingen AN - OPUS4-55625 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Überwachung der Brücke Altstädter Bahnhof, Branden-burg./H. N2 - Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert. T2 - 5. Brückenkolloquium CY - Ostfildern, Germany DA - 06.09.2022 KW - Monitoring KW - Brücke KW - Radar KW - Vibration KW - Faseroptik PY - 2022 AN - OPUS4-55628 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Liao, Chun-Man A1 - Niederleithinger, Ernst T1 - Multi-Sensor measurements on a large-scale bridge model N2 - This contribution introduces an investigation of a large-scale prestressed concrete bridge model (“BLEIB” structure at the BAM-TTS open air test site) by means of on-site cooperative measurements. This bridge has an external post-tensioning system and has been instrumented with the ultrasonic transducers, temperature sensors and optical fibers for Distributed Acoustic Sensing (DAS). Our experiment was designed to test the suitability of the novel 6C sensors developed within the framework of the GIOTTO project – the IMU50. The IMU50 sensor enables vibration measurements in translation along three axes and rotation around three axes. The geophone sensors were considered for complementary measurements of vertical velocity response. In the experiment, several perturbations were achieved by controlling the external influence factors such as loading and prestressing changes. The aim of the integrated measurement strategy was to fully observe the results of the condition change and to verify the effectiveness of multiple sensors for bridge monitoring. T2 - 5. Brückenkolloquium CY - Ostfildern, Germany DA - 06.09.2022 KW - Concrete KW - Bridge KW - Monitoring KW - Rotation KW - Distributed acoustic sensing PY - 2022 AN - OPUS4-55626 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Azari, H. A1 - Shams, S. A1 - Köpp, Christian A1 - Timofeev, Juri A1 - Niederleithinger, Ernst T1 - Development of reference specimens for nondestructive evaluation of concrete bridge decks N2 - Decades of non-destructive evaluation (NDE) for the quality assurance of concrete bridges revealed the necessity of developing procedures for building reference specimens for different defects. External objects have been widely used in specimen construction to represent defects. However, embedded materials can alter the actual defect characteristics, interrupting the NDE responses. This study proposes new approaches to fabricating reference specimens for reinforced concrete that feature substantial defects, including cracks, delamination, honeycombing and rebar corrosion, without external objects. As a result, realistic responses can be acquired to identify promising NDE methods for characterising actual deteriorations. The procedures were produced with the intent of being reproducible in any laboratory. Destructive and non-destructive testing methods were performed to verify the effectiveness of the processes in creating defects. This study provides research laboratories with techniques for fabricating reference specimens for characterising defects and assessing the performance of NDE technologies. KW - Concrete structures KW - Reference KW - Specimen KW - Non-destructive testing KW - Laboratory tests PY - 2023 DO - https://doi.org/10.1680/jfoen.21.00030 SN - 2043-9911 SP - 1 EP - 12 PB - ICE Publishing AN - OPUS4-56957 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Muon tomography applied to assessment of concrete structures: First experiments and simulations. N2 - Non-destructive techniques for reinforced or prestressed concrete inspection such as ultrasound or radar have found regular, successful practical application but sometimes suffer from limited resolution and accuracy, imaging artefacts or restrictions in detecting certain features. Until the 1980s X-ray transmission was used in case of special demands and showed a much better resolution than other NDT techniques. However, due to safety concerns and cost issues, this method is almost never used anymore. Muon tomography has received much attention recently. Novel detectors for cosmic muons and tomographic imaging algorithms have opened new fields of application. As a first step towards practical application in civil engineering and as a proof of concept we used an existing system to image the interior of a reference reinforced 600 kg concrete block. Even with a yet not optimized setup for this kind of investigation, the muon imaging results are at least of similar quality compared to ultrasonic and radar imaging, potentially even better. In a second step, we have performed simulations to assess the potential for a set of important testing problems such as grouting defects in tendon ducts. The next steps include the development of mobile detectors and optimizing acquisition and imaging parameters. T2 - NDT-CE 2022 CY - Zurich, Switzerland DA - 16.08.2022 KW - Muon tomography KW - Concrete KW - Inspection KW - Simulation PY - 2022 AN - OPUS4-56323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maack, Stefan A1 - Niederleithinger, Ernst T1 - Imaging of Ultrasonic Echo Measurements for Reconstruction of Technical Data of Bridges – Possibilities, Limitations and Outlook N2 - When reassessing existing concrete bridges, the challenge is often to obtain missing or incomplete information on the internal structure. In particular, the number and position of the existing reinforcement as well as the geometric dimensions of the components are of interest. Non-destructive testing methods, like radar or ultrasound, which work on the basis of the pulse-echo method, have been established for this purpose, as they only require access to the component from one side. The measurement data recorded on the structure require pre-processing to be able to reproduce the internal structure geometrically accurately. Besides different steps of data processing, the geometrical reconstruction of the measured data based on the Synthetic Aperture Focusing Technique (SAFT) is state of the art today. In this paper, the technical possibilities of the ultrasonic echo method are presented based on measurements in the laboratory and on a real bridge structure. The precision of the reconstruction and its limitations are shown. In addition to the state of the art SAFT technique, open questions and the latest research approaches, such as imaging by reverse time migration (RTM) including initial results are discussed. T2 - 13th German-Japanese Bridge Symposium CY - Osaka, Japan DA - 29.08.2023 KW - Bridge KW - Non destructive testing and evaluation KW - Concrete KW - Validation PY - 2023 SP - 1 EP - 8 AN - OPUS4-58327 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maack, Stefan A1 - Niederleithinger, Ernst T1 - Imaging of Ultrasonic Echo Measurements for Reconstruction of Technical Data of Bridges – Possibilities, Limitations and Outlook N2 - When reassessing existing concrete bridges, the challenge is often to obtain missing or incomplete information on the internal structure. In particular, the number and position of the existing reinforcement as well as the geometric dimensions of the components are of interest. Non-destructive testing methods, like radar or ultrasound, which work on the basis of the pulse-echo method, have been established for this purpose, as they only require access to the component from one side. The measurement data recorded on the structure require pre-processing to be able to reproduce the internal structure geometrically accurately. Besides different steps of data processing, the geometrical reconstruction of the measured data based on the Synthetic Aperture Focusing Technique (SAFT) is state of the art today. In this paper, the technical possibilities of the ultrasonic echo method are presented based on measurements in the laboratory and on a real bridge structure. The precision of the reconstruction and its limitations are shown. In addition to the state of the art SAFT technique, open questions and the latest research approaches, such as imaging by reverse time migration (RTM) including initial results are discussed. T2 - 13th German-Japanese Bridge Symposium CY - Osaka, Japan DA - 29.08.2023 KW - Bridge KW - Non destructive testing and evaluation KW - Concrete KW - Validation PY - 2023 AN - OPUS4-58328 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maack, Stefan A1 - Niederleithinger, Ernst T1 - Low frequency ultrasonic dataset for comparison and validation of signal processing and imaging techniques in civil engineering N2 - The evaluation of technical components and materials in terms of condition and quality with the aid of non-destructive testing methods plays an outstanding role both in industrial serial production and in the individual assessment of components. The ultrasonic echo method is used for a wide variety of testing tasks, such as measuring the thickness of a component. At the Bundesanstalt für Materialforschung und -prüfung (BAM) in Berlin, test methods are developed and their performance is demonstrated. For this purpose, references such as materials, test procedures or data sets are generated, which are used to evaluate these developed test methods. An important component of these references are data sets that are created according to the BAM Data Policy and made available to the scientific community and users of test methods in practice on the basis of the FAIR principles (Findability, Accessibility, Interoperability, and Reuse). T2 - The International Symposium on Nondestructive Testing in Civil Engineering (NDT-CE) 2022 CY - Zurich, Switzerland DA - 16.08.2022 KW - Reference data KW - Non destructive testing and evaluation KW - Ultrasonic KW - Civil engineering PY - 2022 AN - OPUS4-58440 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Current Use of NDT-CE For Infrastructure Inspection and Monitoring in Germany N2 - This presentation gives an overview on current use of NDT-CE for infrastructure inspection and monitoring in Germany. It reflects on challenges, applied standards and guideline including currently developed upgrades. Ways to select proper NDT methods are shown as well as a way how to use NDT results in quantitative, probabilistic strctural assessment. T2 - ISNT NDE2024 Pre-Conference Tutorial on NDT-CE CY - Chennai, India DA - 11.12.2024 KW - NDT-CE KW - Inspection KW - Assessment KW - Standards KW - Guidelines PY - 2024 AN - OPUS4-62197 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - NDT-CE Qualification and Certification in Germany and Elsewhere N2 - Recently first qualification and certification schemes for NDT-CE testing personnel have been introduced and are well booked. The presentation focuses on the two level scheme recently put into standards in Germany. International activities, which favor the traditional three level ISO 9712 scheme, are also discussed. T2 - ISNT NDE2024 Pre-Conference Tutorial on NDT-CE CY - Chennai, India DA - 11.12.2024 KW - NDT-CE KW - Inspection KW - Qualification KW - Certification PY - 2024 AN - OPUS4-62198 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Paths towards digitalization in NDT for Civil Engineering N2 - This presentation shows the concepzual way how to intergrate NDT results into BIM, Digital Twins and more. The concept of BIM, Digital Twins and exchange data formats such as DICONDE and IFC (industry Foundation Classes) are explained. Two examples for Digital Twins are shown. T2 - ISNT NDE 2024 CY - Chennai, India DA - 12.12.2024 KW - NDT-CE KW - Digitalization KW - BIM KW - Digital Twin KW - DICONDE PY - 2024 AN - OPUS4-62202 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Niederleithinger, Ernst ED - Meyendorf, Norbert ED - Ida, Nathan ED - Singh, Ripi ED - Vrana, Johannes T1 - NDE 4.0 in Civil Engineering N2 - There is a tremendous potential for NDE-CE due to the current changes in the construction industry. On the way to a digitized and digitalized way of work, including a shift from traditional ways of planning towards building information modeling, NDE-CE can be of help by providing quality assurance data during and directly after construction, condition data during operation, and missing information about older constructions before rehabilitation or demolition. However, to be successful, NDE-CE methods must be integrated into the data structures used by designers, planners, builders, owners, and users: it must go digital as well. Formats,interfaces, and reliable trusted storage sites for NDE-CE data are urgently required. A working group at DGZfP (“AG ZfPBau 4.0”) and various research project and initiatives are working on these issues but still must get more momentum. KW - NDT-CE KW - NDE 4.0 KW - Digitalization KW - BIM KW - Diconde PY - 2024 SN - 978-3-030-48200-8 DO - https://doi.org/10.1007/978-3-030-48200-8_1-2 SP - 1 EP - 17 PB - Springer CY - Cham AN - OPUS4-62199 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Elastic Reverse Time Migration for Improved Ultrasonic Imaging of Concrete Constructions N2 - The ageing concrete infrastructure worldwide requires a thorough inspection and assessment. The traditional visual and tap testing methods required by many national and international standard have been meanwhile amended by more sophisticated tools like ultrasonic or radar echo technologies. While they can provide a much more detailed image of the interiors of concrete constructions, there are still several unsolved testing tasks on the wish list, such as the reliable sizing of internal objects, e.g. tendon ducts. Reverse Time Migration (RTM) is an imaging technique which is in use in the oil and gas industry for the exploration of new resources with seismic waves as a standard tool. Since about ten years there has been R&D effort to use RTM for imaging of ultrasonic echo data. As it uses the entire wavefield, RTM has some advantages compared to traditional SAFT, e.g. the ability to image vertical structures or the backside of objects. However, this comes with the cost of having to perform full wavefield simulations. We have adopted, improved, and used open source 2D full elastic codes (P/SV waves and SH waves) from geophysics to evaluate the capabilities and limitations of RTM for the imaging of certain features in concrete constructions. We can show the advantages of SH-wave RTM in comparison to SAFT, acoustic RTM and P/SV-based RTM. The findings are demonstrated based on simulated and real data, using a reference test specimen available at BAM. Position and diameter of tendon ducts have been determined with a sub-cm accuracy. T2 - ISNT NDE 2024 CY - Chennai, India DA - 12.12.2024 KW - NDT-CE KW - Ultrasound KW - Imaging KW - Reverse Time Migration KW - Concrete KW - RTM PY - 2024 AN - OPUS4-62203 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dominguez-Bureos, Marco A1 - Sens-Schönfelder, Christoph A1 - Niederleithinger, Ernst A1 - Hadziioannou, Céline T1 - Stress- and Time-dependent Variations of Elastic Properties for Integrity Assessment in a Reinforced Concrete Test Bridge N2 - In lab experiments, it has been observed that the stress–and time-dependent elastic properties of a complex material at a structural scale perform accordingly to its composition at a microstructural level. We seek complementary practices to the current wavefield-based non-destructive testing techniques to assess not only the integrity level of civil structures but also the microstructural elements that contribute to it. In this paper, we study the systematic evolution of elastic properties of concrete as an alternative to investigate the density of micro imperfections in an outdoor-conditioned concrete structure. We estimate 5-second relative velocity changes in four locations on a Test bridge subjected to the action of vertical impulsive sources, at different prestressing levels (dynamic effects at different static conditions). We describe the structure’s stress- and time-dependent elastic response by means of acoustoelastic effect and Slow-dynamic processes, respectively. We also estimate the conventional ultrasound pulse velocity and perform a cooperative integrity analysis of the structure using the three elastic phenomena. Our findings reveal: 1) The presence of soft microstructures and their orientation’s influence on the acoustoelastic effect and Slow-dynamics in field-conditioned concrete structures. 2) The relation of low ultrasound pulse velocities with high acoustoelastic effect and high magnitudes and variability of Slow-dynamics. 3) Different elastic behaviours on the north and south spans of the bridge, suggesting different heterogeneity levels on the analysed locations of the concrete beam. KW - Concrete KW - Ultrasound KW - Nonlinear KW - Elastic properties KW - Damage PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640064 DO - https://doi.org/10.1007/s10921-025-01257-y SN - 0195-9298 VL - 44 IS - 4 SP - 1 EP - 16 PB - Springer Science and Business Media LLC AN - OPUS4-64006 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Zerstörungsfreie Prüfung von Betonkonstruktionen N2 - Der Vortrag behandelt den Stand der Technik bei der zerstörungsfreien Prüfung von Betonkonstruktionen und insbesondere den Stand und die Herausforderungen bei der Digitalisierung. Es werden Prüfaufgaben sowie etablierte Prüfmethoden und die passende Auswahl diskutiert. Ein weitere Schwerpunkt liegt bei der Genauigkeit und Verlässlichkeit und dem Konzept ZfPStatik. Abschließend werden Schnittstellen zu BIM, SIB-Bauwerke und anderen System kurz angerissen und ein Katalog offener Fragen aufgestellt. T2 - Workshop Digitale Bauwerkserhaltung inklusive Bauwerksdiagnose CY - Bonn, Germany DA - 20.02.2024 KW - ZfP-Bau KW - Beton KW - Bauwerksprüfung KW - Digitalisierung KW - ZfPStatik PY - 2024 AN - OPUS4-59547 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Accuracy, Uncertainty, Probability of Detection N2 - This talk presents the concepts of measurement accuracy, uncertainty (in contrast to error analysis) an probability of detection for non-destructive testing. The relevant guidelines (GUM, Mil.Std.) are intrduced and practical examples given. T2 - USES2 Training Week 2 CY - Berlin, Germany DA - 24.06.2024 KW - Uncertainty KW - Pod KW - Measurements PY - 2024 AN - OPUS4-60467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Muon tomography - ready for practical application? N2 - Security and nuclear safeguards, but not yet in civil engineering. The potential is enormous, as muon tomography could replace traditional X-ray imaging of infrastructure, a method that was popular in the past but has mostly been abandoned due to concerns about radiation safety. In 2020, a report on the first large-scale muon tomography experiment on a reinforced concrete specimen was published. However, robust mobile detectors and faster data acquisition methods are still needed. This is now changing, however. Prototype mobile detectors have been announced or are in development, and data acquisition time has been reduced from weeks to days. This presentation will showcase current developments and focus on a validation experiment at BAM. T2 - NDT-CE 2025 - The International Symposium on Nondestructive Testing in Civil Engineering CY - Izmir, Türkiye DA - 24.09.2055 KW - Muon tomography KW - Bridge inspection KW - Concrete PY - 2025 AN - OPUS4-64256 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - ZfP-Bau post Carolabrücke: Chancen und Herausforderungen N2 - Der Einsturz der Carolabrücke hat die Fachwelt, Politik und Öffentlichkeit aufgerüttelt. Während die Diagnose der Ursachen noch andauert (aber wohl zum Vortragzeitpunkt abgeschlossen sein wird), werden erste, nach Ansicht vieler Experten überfällige Konsequenzen gezogen. Zahlreiche Brücken werden vorsichtshalber gesperrt, intensive Prüfungen und Überwachungsmaßnahmen sind veranlasst und werden ausgeweitet. Die Untersuchungsmethodik für Brücken mit dem Verdacht auf Spannungsrisskorrosion und ohne „sicheres“ Ankündigungsverhalten vor Versagen – übrigens keineswegs auf die östlichen Bundesländer beschränkt – steht auf dem Prüfstand. Dabei erhält wohl auch die zerstörungsfreie Prüfung eine veränderte und wichtige Rolle, ebenso wie Methoden zur Dauerüberwachung. Dabei wird aus gutem Grund auf den Stand der Technik zurückgegriffen. Der Vortrag beleuchtet die Rolle der ZfP und die verwendeten Methoden im Rahmen dieser Untersuchungen. Er weist aber auch auf Technologien hin, die in den nächsten Jahren in die Praxis eingeführt werden dürften und zukünftig bei der Untersuchung und Überwachung von Stahl- und Spannbetonbauwerken eine Rolle spielen dürften. T2 - DGZfP Jahrestagung CY - Berlin, Germany DA - 26.05.2025 KW - Zerstörungsfreie Prüfung KW - ZfPBau KW - Brücken KW - Stahlbeton PY - 2025 AN - OPUS4-63230 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Skłodowska, Anna A1 - Coronel Subia, Hernan Alejandro A1 - Inzunza Araya, Ernesto A1 - Niederleithinger, Ernst T1 - Influence of velocity changes on acoustic emission monitoring of masonry walls under diagonal compression load N2 - Acoustic emission (AE) is a highly sensitive, non-destructive method which has great potential in damage event detection and assessment in masonry structures exposed to e.g., seismic loads. However, the highly heterogenous nature of the masonry structures and their low densities cause high attenuation and distortion of the signal. Localization of the AE events is challenging because the AE waves propagate through various masonry constituents (i.e., bricks and mortar joints) at different velocities. We present an attempt to locate the sources of AE events from the signals recorded during the diagonal compression loading, and analyze the influence of different wave velocities on its accuracy. T2 - 36th Conference of the European Working Group on Acoustic Emission CY - Potsdam, Germany DA - 18.09.2024 KW - Acoustic emission KW - Masonry KW - Compression test PY - 2024 AN - OPUS4-61689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bertola, Numa A1 - Schumacher, Thomas A1 - Niederleithinger, Ernst A1 - Brühwiler, Eugen T1 - Combining passive and active ultrasonic stress wave monitoring for the characterization of the early-age properties of a UHPFRC beam N2 - This article focuses on the characterization of the early-age properties of Ultra-High-Performance Fiber-Reinforced Cementitious Composite (UHPFRC), which is becoming popular for designing lightweight and durable structures. Due to the large proportion of cement in the mix, the hardening of UHPFRC is significantly faster than conventional concrete. Therefore, the development of UHPFRC properties, such as the elastic modulus, is difficult to monitor as it happens while elements are within the formwork. For this reason, the hydration process of UHPFRC elements is not fully understood yet. A combined passive (or acoustic emission) and active ultrasonic stress wave monitoring approach has the potential to characterize structures made of cementitious materials over their entire service duration. Using a network of embedded ultrasonic transducers, monitoring can start only a few instants after casting. A UHPFRC beam with a T-shaped cross-section and a length of 4.2 m was constructed and instrumented with 24 transducers as well as 15 thermocouples. Monitoring results lead to the characterization of the development of the early-age UHPFRC properties on the structural-element scale while the specimen is within the formwork. The continuous monitoring approach enabled accurate estimations of the spatial and temporal evolution of the modulus of elasticity. Thanks to this novel combination of monitoring techniques, the early age properties of UHPFRC, which were measured at the material scale, are confirmed at the structural scale for the first time. KW - Concrete KW - UHPFRC KW - Acoustic emission KW - Ultrasonic monitoring KW - Coda wave interferometry PY - 2025 DO - https://doi.org/10.1016/j.conbuildmat.2025.140319 SN - 0950-0618 VL - 466 SP - 1 EP - 18 PB - Elsevier Ltd. AN - OPUS4-63448 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst A1 - Sein, Sander A1 - Kervalisvil, Andrei A1 - Wöstmann, Jens A1 - Helm, Marek T1 - Muon tomography - ready for practical application? N2 - Muon tomography uses naturally occurring nuclear particles to 'X-ray' technical objects. It has applications in security and nuclear safeguards, but not yet in civil engineering. The potential is enormous, as muon tomography could replace traditional X-ray imaging of infrastructure, a method that was popular in the past but has mostly been abandoned due to concerns about radiation safety. In 2020, a report on the first large-scale muon tomography experiment on a reinforced concrete specimen was published. However, robust mobile detectors and faster data acquisition methods are still needed. This is now changing, however. Prototype mobile detectors have been announced or are in development, and data acquisition time has been reduced from weeks to days. This presentation will showcase current developments and focus on a validation experiment at BAM. T2 - NDT-CE 2025 - The International Symposium on Nondestructive Testing in Civil Engineering CY - Izmir, Türkiye DA - 24.09.2025 KW - Concrete KW - Muon tomography KW - Inspection PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-642517 DO - https://doi.org/10.58286/31696 SN - 1435-4934 VL - 30 IS - 10 SP - 1 EP - 10 PB - ndt.net AN - OPUS4-64251 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rabe, Ute A1 - Emge, Julia A1 - Klein, Samuel A1 - Oswald, Jan A1 - Shpakova, Nina A1 - Stopp, Philipp A1 - Weingard, Christoph A1 - Koster, Dirk A1 - Schönsee, Eric A1 - Hille, Frank A1 - Niederleithinger, Ernst T1 - Development of distributed sensor electronics for energy-efficient and proactive maintenance of buildings N2 - Permanently installed sensor systems are becoming increasingly important for monitoring critical infrastructure. The research institutes Fraunhofer IZFP and BAM, together with industrial partners and users, are developing a concept for an electronic system consisting of an Edge-Gateway as a central high-performance node and a variable number of Sensor-Edge units that establish the connection between the sensors of the permanent monitoring system and the gateway, which also provides connection to a cloud. A software tool allows identification and localization of sensors and visualization of sensor data. The principle of the system is demonstrated using sensors installed in the road surface to monitor traffic loads as an example. Two test structures, a full-scale laboratory at Fraunhofer IZFP, Saarbrücken, and the “BLEIB” reference structure at BAM, test site technical safety (TTS) Horstwalde, were used to demonstrate the principle and the functioning of the electronic system. T2 - NDT-CE 2025 - The International Symposium on Nondestructive Testing in Civil Engineering CY - Izmir, Türkiye DA - 24.09.2025 KW - Edge computing KW - Bridge monitoring KW - Multi-sensor PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-642530 DO - https://doi.org/10.58286/31650 SN - 1435-4934 VL - 30 IS - 10 SP - 1 EP - 3 PB - ndt.net AN - OPUS4-64253 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grohmann, Maria A1 - Niederleithinger, Ernst T1 - Application of Elastic Reverse Time Migration to Ultrasonic Echo Data from Concrete Structures N2 - To enhance ultrasonic imaging of concrete structures, we adapted the geophysical migration method, Reverse Time Migration (RTM), for non-destructive testing (NDT) in civil engineering. First, two 2D elastic RTM algorithms, each considering different wave types, were implemented and evaluated with synthetic ultrasonic data. The algorithm that best resolved numerical concrete structures was subsequently applied to real ultrasonic data from a concrete specimen. Compared with conventional synthetic aperture focusing technique (SAFT) imaging, elastic RTM reproduced a greater number of structural features in both the numerical model and the concrete specimen. In particular, elastic RTM reconstructed vertical interfaces as well as hidden lower edges of modeled cavities and tendon ducts. Notably, imaging the full cross-sections of tendon ducts, which enables direct diameter estimation, represents a novel achievement for ultrasonic NDT. T2 - NDT-CE 2025 - The International Symposium on Nondestructive Testing in Civil Engineering CY - Izmir, Turkey DA - 24.09.2025 KW - Concrete Structures KW - Ultrasonic Echo Technique KW - Ultrasonic Imaging KW - Elastic Reverse Time Migration KW - Synthetic Aperture Focusing Technique PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-650350 DO - https://doi.org/10.58286/31680 SN - 1435-4934 SP - 1 EP - 3 PB - e-Journal of Nondestructive Testing CY - www.ndt.net AN - OPUS4-65035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas A1 - Sanchez Trujillo, Camila Andrea A1 - Hau, Julia A1 - Niederleithinger, Ernst A1 - Malm, F. T1 - Structural Monitoring in an Urban Underground Metro Station Using Cod N2 - Active ultrasonic monitoring with coda wave interferometry has demonstrated its potential for structural Health monitoring in concrete structures. This study investigates its application using ultrasonic transducers embedded in the ceiling of a subway station in Munich, Germany. We evaluate the impact of environmental conditions, specifically electromagnetic interference and temperature, on data quality, as well as the influence of regular loading from passing trams. Results indicate that electromagnetic interference significantly affects measurements, while temperature effects remain minimal due to the station’s stable thermal environment. Long-term measurements and a controlled load test show that both dynamic and static loading from trams induce ultrasonic velocity changes of only 0.01%–0.06%. Although the experiment demonstrates the capacity to detect structural responses and supports the feasibility of long-term monitoring, improved electromagnetic shielding and Hardware reliability are required for successful future applications. T2 - NDT-CE 2025 CY - Izmir, Turkey DA - 24.09.2025 KW - Coda Wave Interferometry (CWI) KW - Structural health monitoring (SHM) KW - Concrete KW - Ultrasonic testing KW - Urban infrastructure PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654619 DO - https://doi.org/10.58286/31706 SN - 1435-4934 SP - 1 EP - 10 PB - e-Journal of Nondestructive Testing (eJNDT) AN - OPUS4-65461 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - NDE of foundations N2 - This talk teaches the basic princioles and applications of NDT methods for deep foundations, sprecifically piles. A variety of testing methods are discussed (integrity testing, ultrasonic crosshole logging, parallel seismic and others). Capabilities and limitations are given as well as specific hints for practical use. T2 - NDE 2019 Pre-Conference Tutorial PCT 4 CY - Bangalore, India DA - 03.12.2019 KW - NDT KW - Foundation KW - Pile KW - Integrity testing PY - 2019 AN - OPUS4-50169 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Recent advances in NDE of concrete structures at BAM N2 - This talk gives an introduction to BAM and its NDT-CE division. Specific challenges in NDT-CE are discussed as well as recent research results. T2 - NDE 2019 Pre-Conference Tutorial PCT 4 CY - Bangalore, India DA - 03.12.2019 KW - NDT KW - Civil engineering PY - 2019 AN - OPUS4-50168 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Ultrasonic methods for concrete: To boldly see, what we have not seen before N2 - This keynote talk at NDE 2019 discusses specific progress in ultrasonic testing of concrete structures. A deep penetration instrument (LAUS) is introduced as well as advanced imaging methods adopted from geophysics and new approaches to ultrasonic monitoring. T2 - NDE 2019 CY - Bangalore, India DA - 05.12.2019 KW - NDT KW - Concrete KW - Ultrasound KW - Imaging KW - Monitoring PY - 2019 AN - OPUS4-50170 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Ultrasonic monitoring of structural concrete elements N2 - Ultrasonic transmission measurements are used to monitor concrete elements mostly on a laboratory scale since decades. Recently, coda wave interferometry, a technique adapted from seismology, has been introduced to civil engineering experiments. It can be used to reveal subtle changes in concrete samples and even large construction elements without having a transducer directly at the location where the change is taking place. The methodology works best with embedded transducers to avoid coupling issues or excessive environmental influence. These transducers can be used for newly built and existing structures. Recently, large concrete beams have been equipped with a network of transducers and loaded until failure. Using code wave interferometry, it was possible to visualize stress fields and damaged areas. This paper gives an overview of the state of the art, recent results achieved at BAM and a task list for further results and development. T2 - International Conference on Sustainable Materials, Systems and Structures (SMSS 2019) CY - Rovinj, Croatia DA - 20.03.2019 KW - Concrete KW - Ultrasound KW - Monitoring KW - coda wave interferometry PY - 2019 AN - OPUS4-47676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schumacher, T. A1 - Murtuz, A. K. M. G. A1 - Hafiz, A. A1 - Dusicka, P. A1 - Niederleithinger, Ernst ED - Gabrijel, I. ED - Grosse, C. ED - Skazlić, M. T1 - Post-earthquake damage evaluation of concrete structures using ultrasonic monitoring: A proof-of concept laboratory study N2 - In earthquake-prone regions such as the Pacific Northwest, damage assessment tools are needed to enable safety evaluations to support recovery. Currently, damage assessment is performed primarily by visual inspection and is often impossible for structural members that are inaccessible, such as deep foundations or interior members hidden by cladding. This study explores the possibility of using embedded ultrasonic transducers to monitor reinforced concrete members for damage progression under earthquake loading. A novel methodology is proposed where changes in the member condition due to an increase in the earthquake-type loading of a full-scale column-foundation specimen are correlated with changes in the recorded ultrasonic waveforms. The discussed preliminary analysis of the ultrasonic signals is based on wave propagation velocity, changes in the coda wave portion, and maximum amplitude of the signals. Three embedded transducers were used to continuously monitor the laboratory specimen during destructive testing. This paper provides an overview of the proposed methodology, outlines the laboratory experiment, and discusses some preliminary observations. T2 - International Conference on Sustainable Materials, Systems and Structures (SMSS 2019) CY - Rovinj, Croatia DA - 20.3.2019 KW - Concrete KW - Monitoring KW - Ultrasound KW - earthquake PY - 2019 SN - 978-2-35158-227-5 DO - https://doi.org/10.1007/978-3-031-07258-1_84 SP - 112 EP - 119 PB - RILEM Publications S.A.R.L. CY - Paris, France AN - OPUS4-47679 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst ED - Gabrijel, Ivan ED - Grosse, Christian ED - Skazlić, Marijan T1 - Ultrasonic monitoring of structural concrete elements N2 - Ultrasonic transmission measurements are used to monitor concrete elements mostly on a laboratory scale since decades. Recently, coda wave interferometry, a technique adapted from seismology, has been introduced to civil engineering experiments. It can be used to reveal subtle changes in concrete samples and even large construction elements without having a transducer directly at the location where the change is taking place. The methodology works best with embedded transducers to avoid coupling issues or excessive environmental influence. These transducers can be used for newly built and existing structures. Recently, large concrete beams have been equipped with a network of transducers and loaded until failure. Using code wave interferometry, it was possible to visualize stress fields and damaged areas. This paper gives an overview of the state of the art, recent results achieved at BAM and a task list for further results and development. T2 - International Conference on Sustainable Materials, Systems and Structures (SMSS 2019) CY - Rovinj, Croatia DA - 20.3.2019 KW - Concrete KW - Ultrasound KW - Monitoring KW - coda wave interferometry PY - 2019 SN - 978-2-35158-227-5 SP - 1 EP - 11 PB - RILEM Publications S.A.R.L. CY - Paris, France AN - OPUS4-47677 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst A1 - Maak, Stefan A1 - Mielentz, Frank A1 - Effner, Ute A1 - Strangfeld, Christoph A1 - Timofeev, Juri T1 - Review of recent developments in ultrasonic echo testing of concrete N2 - Ultrasonic methods are used in concrete investigations since decades. While being limited to transmission testing in the laboratory for a while, in-situ echo measurements for structural investigations and condition assessment have made their way into practical application in the past 20 years. However, several challenges remain. On one side, there are technical issues as limitations in depth of penetration, resolution and imaging capabilities. On the other side there are still gaps in validation, standardization and certification, which are limiting the applicability in condition/load capacity assessment. This review reports a couple of developments which will help to overcome these issues. This includes technical developments as new devices which are easier to handle on site or giving a much deeper penetration depth (e.g. the LAUS device at BAM) as well as improvements in imaging by hardware update (e. g. air coupled ultrasound or coded signals) or new software (e. g. RTM imaging). To foster the application in real world projects we are as well working on standardization by developing new reference specimen with international partners which will ensure world-wide comparability of ultrasonic and other methods and quality assurance codes. Further, non-destructive methods are being used to update probabilistic models used for the reassessment of existing structures to support the structural engineer’s decisions. T2 - SMAR 2019 CY - Potsdam, Germany DA - 27.08.2019 KW - Engineered Barrier System (EBS) KW - Ultraschall KW - NDT KW - Re-assessment of exiting bridges PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-489686 SP - 1 EP - 6 AN - OPUS4-48968 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Große, Christian A1 - Arndt, Ralf A1 - Mähner, Dietmar A1 - Niederleithinger, Ernst A1 - Taffe, Alexander T1 - Zerstörungsfreie Prüfung im Bauwesen: Memorandum zur Lehre an deutschsprachigen Hochschulen N2 - Dieses erste Memorandum zur Lehre und Forschung an deutschsprachigen Hochschulen auf dem Gebiet der zerstörungsfreien Prüfung im Bauwesen gibt einen Überblick hinsichtlich der akademischen Ausbildung und zeigt mögliche Schwerpunkte vor allem in der Lehre auf. Diese Schwerpunkte berücksichtigen auch aktuelle Entwicklungen und Themen auf dem Gebiet der Forschung. Es werden Anregungen zur Entwicklung bzw. Weiterentwicklung der Lehr-Curricula im Hinblick auf eine umfassende und solide fachliche Ausbildung der Studierenden des Bauwesens und angrenzender Fachrichtungen gegeben. Inhaltlich und formal lehnt sich der Beitrag an dem Memorandum der Hochschullehrer im Fachgebiet „Werkstoffe im Bauwesen“ (Breit et al., 2012) an und beruht auf einer Initiative des Unterausschusses Ausbildung – Arbeitsgruppe Ausbildung in der Hochschule – des Fachausschusses ZfP im Bauwesen der Deutschen Gesellschaft für zerstörungsfreie Prüfung (DGZfP). Die Hauptredaktion wurde übernommen von Prof. Christian U. Grosse (TU München) und Prof. Ralf W. Arndt (FH Erfurt). KW - Zerstörungsfreie Prüfung KW - Lehrplan KW - Bauwesen PY - 2019 UR - https://onlinelibrary.wiley.com/doi/epdf/10.1002/bate.201900008 DO - https://doi.org/10.1002/bate.201900008 SN - 1437-0999 SN - 0932-8351 VL - 96 IS - 4 SP - 360 EP - 368 PB - Ernst & Sohn CY - Berlin AN - OPUS4-47606 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ertel, Jens-Peter A1 - Niederleithinger, Ernst ED - Bullock, P. ED - Verbeek, G. ED - Paikowsky, S. ED - Tara, D. T1 - Impulse Response Measurement for Pile Integrity Testing Using a Shaker as Excitation Source and Regularized Deconvolution N2 - Concrete piles are used as a foundation when the load capacity of the soil is insufficient or when the sustainable soil is found at a higher depth. Among other impact factors, the load capacity depends on the pile’s integrity and length. Therefore, verifying these parameters using adequate methods is recommended. The most common procedure is the low-strain integrity test using the hammer impact method. Developed and established in the 1970s, this method uses stress waves induced by a hammer impact at the pile head and its reflections at impedance changes (length, defects, geometry changes) to estimate the length and defect locations. Although this method is widely used due to its low cost and fast conduction in situ, one disadvantage is its inability to classify the exact type of defect, i.e., crack, change in diameter, or concrete quality. Furthermore, very long and slender piles are difficult to test and small defects cannot be detected. In addition, it is necessary for the test engineer to hold a high level of experience and expertise in this field. The European Union–funded PileInspect project (2013–2016) aimed to compensate for these disadvantages by using a low-cost shaker as the excitation source and sophisticated artificial intelligence algorithms for damage detection (higher-order spectra method). Because this technology lacks the capacity to localize damages and verify the pile length, an additional impulse response (IR) measurement technique was developed using vibrational excitation and regularized deconvolution to extract the depth information from the data in a similar manner as the hammer method. Simulations and subsequent experiments conducted at a test facility on 90-cm-diameter bored piles 11 m in length and containing cracks at approximately 4 m below the pile head confirmed the capacity to determine the pile length. Damage diagnosis and localization, however, are more difficult than for the hammer method. Although the damaged piles could be distinguished from the intact piles, in a blind test, this method might lead to misinterpretations caused by perturbations arising from the deconvolution process. The results also indicated that the low-cost shaker used for these measurements might be inappropriate for the transferal of sufficient energy. Although the IR method cannot compensate for the disadvantages of the hammer method by itself, it may enable the possibility of using long and fully controllable and repeatable signals (chirp, synthetic impacts, even noise, etc.) for pile integrity testing in the future. KW - Pile integrity testing KW - L-curve KW - Tikhonov regularization KW - NDT PY - 2019 SN - 978-0-8031-7667-6 DO - https://doi.org/10.1520/STP161120170162 VL - 1611 SP - 184 EP - 204 PB - ASTM International CY - West Conshohoken, PA, USA AN - OPUS4-48794 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zheng, H. A1 - Ertel, Jens-Peter A1 - Kourmpetis, M. A1 - Kanfoud, J. A1 - Niederleithinger, Ernst A1 - Gan, T.-H. T1 - Integrity testing of cast in situ concrete piles based on an impulse response function method using sine‑sweep excitation by a shaker N2 - In this study, an Impulse Response Function analysis of pile response to sine-sweep excitation by a low cost, portable Shaker was used to identify defects in piles. In straightforward impact-echo methods, echoes from the pile toe and defects are visible in the time domain measurements. However, these echoes are not present in the time domain records of piles subjected to sine-sweep excitations, due to interactions between the input and output signals. For this reason, the impulse response function in the time domain has been calculated and is able to identify the echoes from pile impedance changes. The proposed methodology has been evaluated both numerically and experimentally. A one-dimensional pile-soil interaction system was developed, and a finite difference method used to calculate the pile response to sine-sweep excitation. The numerical simulations indicate that impulse response measurements with a synthesized logarithmic, sine-sweep excitation could be an effective tool for detecting defects in piles. The methodology was further tested with field trials on 6 cast in situ concrete test piles including 1 intact pile and 5 defective piles subjected to sine-sweep excitations by a shaker. In 5 of the 6 cases the echoes from the pile toe could be identified in the deconvoluted waveforms—the impulse Response functions. Damage detection is more difficult and dependent on the selection of the optimal regularization parameter. Further research and optimization of the deconvolution process is needed to evaluate the effectiveness compared to standard pile integrity testing methods. KW - Pile testing KW - Shaker KW - Deconvolution PY - 2019 DO - https://doi.org/10.1007/s10921-019-0595-4 SN - 0195-9298 SN - 1573-4862 VL - 38 IS - 2 SP - 55, 1 EP - 18 PB - Springer CY - Cham, Switzerland AN - OPUS4-48185 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vössing, Konrad A1 - Gaal, Mate A1 - Niederleithinger, Ernst ED - Ross, R. ED - Sauter, U. T1 - Contactless testing of wood-based materials with novel air-coupled ultrasonic transducers N2 - The detection of delamination, rot and cracks causing a decrease of strength in wooden construction elements is a key task for nondestructive testing (NDT). Air-coupled ultrasound (ACU) is used to detect flaws without having to provide contact to the surface or otherwise affect the object. Novel ferroelectric transducers with a high signal-to-noise ratio enable an accurate flaw detection. Transducers made of cellular polypropylene (PP) are suitable for characterizing wood-based materials (WBM) because their extremely low Young’s modulus and low density mean a favorable acoustic impedance for the transmission of ultrasonic waves between the transducer and air. The transducers can be applied during the production of WBM and during its service life. The device enables a fast in-situ recognition of defects with frequencies between 90 kHz and 250 kHz. Measurements can be performed in through transmission for a high resolution or in pulse-echo technique in case of one-sided access at the expense of reduced signal strength. Ultrasonic quality assurance for wood is an important attempt to increase the acceptance of wooden structures and towards sustainability in civil engineering in general. T2 - 21. International Nondestructive Testing and evaluation of Wood Symposium CY - Freiburg, Germany DA - 24.09.2019 KW - Air-coupled ultrasound KW - Defect detection KW - Nondestructive Testing KW - Timber PY - 2019 SP - 100 PB - FVA CY - Freiburg AN - OPUS4-49169 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - Seismic methods to test concrete strcutures N2 - Seismic methods are increasingly used to improve ultrasonic imaging and monitoring of concrete. At BAM, we are research mainly the use of Reverse Time Migration to get better images from ultrasonic echo data of thick, complex concrete structures. Coda wave interferometry is used to detect subtle changes in concrete constructions, e. g. using embedded ultasonic transducers. T2 - Geophysikalisches Seminar der Universität Potsdam CY - Potsdam,. Germany DA - 25.01.2019 KW - Concrete KW - Ultrasound KW - Monitoring KW - Imaging PY - 2019 AN - OPUS4-47302 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst T1 - PileInspect N2 - The EC funded project PileInspect (2013-2016) has tried to improve the traditional low strain pile integrity test by using a shaker instead of a hamm and sophisticated higher order spectra analysis methods to provide automated, reliable interpretation. However, the results, even if promising, have not seen full validation yet. A second module, providing depth information by regularized deconvolution, was developed and tested successfully, but doesn't deliver additional information compared tomteh traditioanl test. T2 - DFI Seminar Pile Integrity Testing CY - Bruxelles, Belgium DA - 12.09.2019 KW - Pile integrity testing KW - Shaker KW - Higher order spectra KW - Deconvolution PY - 2019 AN - OPUS4-48948 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dackermann, U. A1 - Yu, Y. A1 - Niederleithinger, Ernst A1 - Li, J. A1 - Wiggenhauser, Herbert T1 - Condition Assessment of Foundation Piles and Utility Poles Based on Guided Wave Propagation Using a Network of Tactile Transducers and Support Vector Machines N2 - This paper presents a novel non-destructive testing and health monitoring system using a network of tactile transducers and accelerometers for the condition assessment and damage classification of foundation piles and utility poles. While in traditional pile integrity testing an impact hammer with broadband frequency excitation is typically used, the proposed testing system utilizes an innovative excitation system based on a network of tactile transducers to induce controlled narrow-band frequency stress waves. Thereby, the simultaneous excitation of multiple stress wave types and modes is avoided (or at least reduced), and targeted wave forms can be generated. The new testing system enables the testing and monitoring of foundation piles and utility poles where the top is inaccessible, making the new testing system suitable, for example, for the condition assessment of pile structures with obstructed heads and of poles with live wires. For system validation, the new system was experimentally tested on nine timber and concrete poles that were inflicted with several types of damage. The tactile transducers were excited with continuous sine wave signals of 1 kHz frequency. Support vector machines were employed together with advanced signal processing algorithms to distinguish recorded stress wave signals from pole structures with different types of damage. The results show that using fast Fourier transform signals, combined with principal component analysis as the input feature vector for support vector machine (SVM) classifiers with different kernel functions, can achieve damage classification with accuracies of 92.5% ± 7.5%. KW - Structural Health Monitoring KW - Non-Destructive Testing KW - Sensor network KW - Support vector machine KW - Utility poles PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-434868 UR - http://www.mdpi.com/1424-8220/17/12/2938 DO - https://doi.org/10.3390/s17122938 SN - 1424-8220 VL - 17 IS - 12 SP - Article 2938, 1 EP - 16 PB - MDPI CY - Basel, Schweiz AN - OPUS4-43486 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Niederleithinger, Ernst A1 - Abraham, O. A1 - Mooney, M. T1 - Geophysical methods in civil engineering: Overview and new concepts N2 - Geophysical methods have been used in civil engineering for decades. The main field of application is - to no surprise – in geotechnical projects from site characterization to foundation quality assurance. For more than 25 years, ground penetrating radar (GPR) and seismic methods have found applications in structural engineering. Recently introduced geophysical methods have been adopted to ultrasonic investigations in various fields. They help to improve the quality of structural imaging and to detect small changes in concrete. An overview of the history and current use of geophysics in civil engineering is given. Selected examples of new concepts include advances in wave based imaging, quality assurance for foundations, detecting small changes in concrete as well as moisture and corrosion detection are discussed. T2 - NDT-CE 2015 - International symposium non-destructive testing in civil engineering CY - Berlin, Germany DA - 15.09.2015 KW - Nondestructive testing KW - Civil engineering KW - Geophysics PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-344666 UR - https://www.ndt.net/?id=18260 SN - 1435-4934 VL - 20 IS - 11 SP - 1 EP - 6 PB - NDT.net CY - Kirchwald AN - OPUS4-34466 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Niederleithinger, Ernst A1 - Wolf, Julia A1 - Mielentz, Frank A1 - Wiggenhauser, Herbert T1 - Using embedded ultrasonic sensors for active and passive concrete monitoring N2 - Challenging new constructions and ageing infrastructure are increasing the demand for permanent monitoring of loads and condition. Various methods and sensors are used for this purpose. But the technologies available today have difficulties in detecting slowly progressing locally confined damages. Extensive investigations or instrumentations are required so far for this purpose. In this study we present new sensors and data processing methods for ultrasonic transmission, which can be used for non-destructive long term monitoring of concrete. They can be mounted during construction or thereafter. Larger volumes can be monitored by a limited number of sensors for changes of material properties. The principles of ultrasonic transmission and influencing factors are presented. This latter include load, damages as well as environmental parameters as temperature or moisture. Various methods for data processing, e. g. coda wave interferometry are introduced. They allow the detection of very small changes in the medium. The embedded sensors are shown including mounting and operation. Application examples so far include small scale laboratory freeze-thaw experiments, localizing loads in larger concrete models, monitoring load effects on real structures as well as detecting acoustic events. Some sensors are operating already for several years. The sensors can be used as transmitter or receivers or switched between both roles. While most of the previous experiments have been active (at least one sensor serving as transmitter), new studies show that the sensors are useful as well for passive measurements, e. g. in acoustic emission or time reversal experiments. Besides application in civil engineering our setups can also be used for model studies in geosciences. T2 - NDT-CE 2015 - International symposium non-destructive testing in civil engineering CY - Berlin, Germany DA - 15.09.2015 KW - SHM KW - Monitoring KW - Ultrasound concrete KW - Embedded sensors PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-344652 UR - http://www.ndt.net/?id=18408 SN - 1435-4934 VL - 20 IS - 11 SP - 1 EP - 4 PB - NDT.net CY - Kirchwald AN - OPUS4-34465 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Galindo Guerreros, Julio Cesar A1 - Niederleithinger, Ernst A1 - Mackens, S. A1 - Fechner, T. T1 - Quality assurance of jet grout columns with borehole seismic measurements N2 - Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. One commonly applied method is jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty linked with this method is to predict the resulting column diameter and its material strength. In this paper we illustrate the application of a newly developed non-destructive quality assurance testing tool used to determine the diameter of jet grout columns. This approach incorporates standard crosshole and downhole seismic measurements. To demonstrate its effectiveness, we tested the new approach within two-dimensional finite-difference numerical simulations. Additional field tests showed that this tool is also applicable in real site conditions. For this purpose, three jet grout columns were produced with different process parameters in a depth between 3.0 and 10 m. The evaluated diameters were within 1.0 and 1.5 m, slightly deviating from the previously predicted range by the jet grouting contractor. Moreover, we were able to detect the base of the columns at 10 m depth with no significant difficulties. On the other hand, unsaturated, partly unconsolidated sands between ground water level and surface considerably affected the seismic data, hence complicating the detection of the top of the columns. T2 - NDT-CE 2015 - International symposium non-destructive testing in civil engineering CY - Berlin, Germany DA - 15.09.2015 KW - Jet grout KW - Seismics KW - Crosshole KW - Downhole PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-346753 UR - https://www.ndt.net/?id=18277 SN - 1435-4934 VL - 20 IS - 11 SP - 1 EP - 7 PB - NDT.net CY - Kirchwald AN - OPUS4-34675 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Liao, Chun-Man A1 - Bernauer, F. A1 - Niederleithinger, Ernst A1 - Igel, H. A1 - Hadziioannou, C. T1 - Assessment of prestress loss in a large-scale concrete bridge model under outdoor condition N2 - Environmental conditions affect the accuracy of field measurements used to monitor civil structures. Previous studies have shown that measured dynamic responses often lack the sensitivity needed for effective localized damage detection. To address this issue, our study focuses on distinguishing environmental effects from damage related effects in measured data to enhance vibration-based damage identification methods. Experimentally, the problem of prestress loss in a prestressed concrete bridge model was examined. By adjusting the pre-stressing force in a large-scale concrete bridge model, cracking phenomena were observed. To demonstrate field monitoring of a large-scale prestressed structure, noise recording was performed and the measurement data was analyzed with operational modal analysis. Additionally, ultrasonic testing, known for its high sensitivity in damage localization, was used to cross-check the structural damage. Seismic and coda wave interferometry were also employed to estimate wave velocities, providing insights into the level of prestress loss and temperature sensitivity. Ultimately, these measurable wave properties help to overcome the uncertainties associated with traditional vibration-based damage detection methods. T2 - EVACES 2025 CY - Porto, Portugal DA - 02.07.2025 KW - Prestress Loss KW - NDT KW - Ambient Vibration KW - Ultrasonic Testing KW - Coda Wave Interferometry KW - Seismic Interferometry PY - 2025 SN - 978-3-031-96105-2 DO - https://doi.org/10.1007/978-3-031-96106-9_20 VL - 675 SP - 181 EP - 189 PB - Springer Nature CY - Cham AN - OPUS4-64212 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jägle, Eva A1 - Tuladhar, Rujika A1 - Niederleithinger, Ernst A1 - Epple, Niklas A1 - Sanchez Trujillo, Camila Andrea A1 - Gehlen, Christoph A1 - Timothy, Jithender J. T1 - Evaluation of ultrasonic signals collected from laboratory concrete specimens: Preprocessing and analysis with coda wave interferometry N2 - Efficient maintenance of infrastructure relies on monitoring and assessment of its condition. New technologies and methods thereby enable a deeper understanding of the materials used and of the structures built. Coda Wave Interferometry (CWI) is currently explored for continuous monitoring of reinforced concrete structures as well as material testing. This ultrasound-based method is sensitive to even small material alterations and therefore suitable for the detection of initial damage stages. Herein, a step-by-step procedure for the evaluation of ultrasonic signals with CWI methods is presented. The described procedure is proposed for ultrasonic signals collected with embedded ultrasonic transducers with a center frequency of 50 kHz to 70 kHz from prism-shaped concrete specimen with dimensions of 400 mm x 100 mm x 100 mm. The raw ultrasonic signal, preprocessing and CWI analysis are described and influences of parameters within the analysis are discussed. The presented procedure allows systematic and comparable analysis of ultrasonic signals generated with similar conditions and therefore contributes to the application of CWI methods for structural health monitoring and material testing. KW - Ultrasound KW - Concrete KW - Coda wave interferometry KW - Structural health monitoring PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-656027 DO - https://doi.org/10.1016/j.mex.2026.103811 SN - 2215-0161 VL - 16 SP - 1 EP - 19 PB - Elsevier B.V. AN - OPUS4-65602 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -