TY - JOUR A1 - Camplese, D. A1 - Chianese, C. A1 - Scarponi, G. A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, V. T1 - Analysis of high temperature degradation of multi-layer insulation (MLI) systems for liquid hydrogen storage tanks N2 - The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire. T2 - ICheaP 16 CY - Naples, Italy DA - 21.05.2023 KW - LH2 KW - MLI KW - Tiefkalt KW - Fire KW - Tank PY - 2023 SN - 2283-9216 VL - 2023 SP - 1 EP - 6 PB - AIDIC Servizi S.r.l. AN - OPUS4-57584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Wasserstoff - Kryogene Anwendungen N2 - Wasserstoff wird als ein potenzieller alternativer Energieträger gesehen, mit dem die für 2050 gesetzten Klimaziele erreicht werden könnten. Der Transport von Wasserstoff ist mittels verschiedener Speichertechniken möglich, von denen der kryogene Transport mit den größten volumetrischen Energiedichten einhergeht. Hierdurch eignen sich diese Speicher besonders für die energieintensiven Verkehrsmittel im Land-, See- und Flugverkehr. Im Vortrag werden Speichertechniken, Gefahren im Umgang mit kryogenen Gasen sowie bisherige Störfälle dargestellt. Darauf aufbauend wird ein Teil der aktuellen Forschungsarbeit an der BAM vorgestellt, die die Sicherheit dieser Speicher unter außergewöhnlichen Belastungen adressiert. T2 - 26. Gefahrgutkongress Mecklenburg-Vorpommern CY - Rostock, Germany DA - 03.11.2022 KW - Wasserstoff KW - H2 KW - LNG KW - LH2 KW - Tank PY - 2022 AN - OPUS4-56181 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Camplese, D. T1 - Analysis of high temperature degradation of multi-layer insulation (MLI) systems for liquid hydrogen storage tanks N2 - The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire. T2 - ICheaP 16 CY - Naples, Italy DA - 21.05.2023 KW - LH2 KW - MLI KW - Fire KW - Tank PY - 2023 AN - OPUS4-57553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Tanks For The Large-Scale Transport And Storage Of Liquefied Hydrogen N2 - Hydrogen is seen as a potential energy source that enables us to achieve our climate targets. Hydrogen can be well integrated into the electrical energy infrastructure, and its production and use is free of direct GHG emissions. However, tanks are needed for worldwide storage and transportation, which need to be further developed and up-scaled. In the EU-funded NICOLHy project, BAM investigates a novel insulation concept based on Vacuum Insulation Panels (VIP) that enables the safe, cost- and energy-efficient storage of large quantities of LH2. Such large-scale LH2 storage technology is necessary to build tanks with capacities of 40.000 m³ to more than 200.000 m³ of LH2, as it is in application for LNG today. However, new design concepts are needed because the currently available technologies used in small and medium storages today are not suitable for up-scaling. The main problems prohibiting up-scaling are the long production time due to the process chain, the low failure tolerance, and the spherical shape of the tank, which reduces the payload in technical applications by up to 50% compared to other shapes. The novel concept will change these conditions by a system which is modular, open-form, time-and cost-efficient during production, operation and service, multi-failure tolerant and applicable for onshore and offshore applications. The NICOLHy consortium is ideally suited for this ambitious project. It brings together experts from the fields of thermodynamics, cryogenics, marine, chemistry, process, and safety engineering. Thereby, NICOLHy will accelerate the integration of hydrogen into the European energy economy and industry, which is necessary to be in line with the European Green Deal and to build trust of society in the policy and the technology. T2 - BAM Akademie H2 Safety - Colloquium CY - Berlin, Germany DA - 06.11.2024 KW - LH2 KW - Insulation KW - Liquefied Hydrogen KW - Tank PY - 2024 AN - OPUS4-61540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Systems for the storage of cryogenic liquefied gases N2 - Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Its storage requires tanks with Thermal Super Insulations (TSI) to keep the transported fluid cold. The presentation includes 2 main topics of the department. First TSI has proven itself in various applications over a long time, but not in the land transport sector, where accidents involving collisions, fires, and their combination are to be expected. To analyze fire scenarios a High-Temperature Thermal Vacuum Chamber (HTTVC) was developed that allows the thermal loading of thermal insulation material in a vacuum and measuring the heat flow through the TSI in parallel. Within this chamber, 5 samples were tested regarding 3 different types of MLI, rock wool, and perlites. In the presentation, the results are presented. Second, the studying of accident scenarios enables the improvement of thermal superinsulation and to find novel insulation concepts. This is necessary for LH2 large-scale storages, for which state-of-the-art solutions are not suitable. Within the presentation, a novel insulation concept will be presented. T2 - Specialist Meeting - Threats to HAZMAT Pressure Vessels and BLEVE CY - Berlin, Germany DA - 25.04.2023 KW - Crygenic KW - LH2 KW - LNG KW - Fire KW - MLI PY - 2023 AN - OPUS4-57414 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - LH2 Tanks In Fire Incidents - The Cryogenic High Temperature Thermal Vacuum Chamber Enables In-Depth Insights N2 - Liquefied Hydrogen (LH2) and Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Their storage requires tanks with thermal super-insulations to keep them at cryogenic conditions for a long time. These insulation systems have proven itself in various applications over a long time. However, these insulations are still new in land transportation, where accidents involving collisions, fires, and their combination are to be expected. This study summarizes the results of the ongoing research program in which insulations commonly used in industry were analysed through experimental and numerical studies under fire-like conditions. It was found that there are strong differences among the various insulation systems. Several safety concerns and research gaps exists for layered insulations, which are typically used in land transport. To further analyse these insulation systems, a new test concept called Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC) was developed and manufactured. This concept enables the testing of large insulation samples under industrial conditions and the consideration of cryogenic conditions relevant for the investigation of various phenomena. The results are important for the evaluation of accident scenarios, the improvement of thermal super-insulations, and the development of emergency measures. T2 - IMECE 2024 CY - Portland, OR, USA DA - 17.11.2024 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety PY - 2024 AN - OPUS4-61752 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Comparative performance assessment of multilayer insulation (MLI) systems for liquid hydrogen vessels in fire scenarios N2 - Multilayer Insulation (MLI) systems are a mature technology for cryogenic liquid hydrogen (LH2) tank thermal insulation. Recent tests evidenced that MLI materials may be damaged when exposed to fire, resulting in critical safety issues in the case of accidents. Thus, an innovative approach to the performance assessment of aluminum and polyester-based MLIs for LH2 tanks in fire scenarios was developed. A specific model integrating the hightemperature degradation of MLIs and the thermodynamic modeling of the tank lading was coupled to specific key performance indicators. Results of the analysis applied to a vehicle-scale tank equipped with 80 MLI layers indicate that MLI degradation and consequent tank failure may occur in less than 20 min for external shell temperatures above 1160 K in the presence of full engulfment, regardless of insulation used. Conversely, degradation does not occur earlier than 3600s below 603 and 928 K for polyester and aluminum-based MLI, respectively. KW - LH2 KW - LNG KW - Cryogenic storage tank KW - Fire KW - Insulation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-630841 DO - https://doi.org/10.1016/j.ijhydene.2025.04.534 SN - 0360-3199 VL - 135 SP - 537 EP - 552 PB - Elsevier Ltd. AN - OPUS4-63084 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - Repeatable Testing of a Cryogenic Storage Tank with Variable Insulation Material in Fire Like Conditions N2 - For decarbonizing the energy industry and transport, cryogenic energy carriers have great potential. The storage takes place in tanks with thermal super-insulations, which are in application for decades, but there is only limited knowledge about its behaviour in a fire scenario. This represents a major incident that may generate extraordinary loads on the tank and its insulation system, and that eventually lead to a sudden tank failure. This paper presents a test rig called the Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC), which can be used to test typical thermal superinsulation’s under cryogenic and fire-like conditions in parallel. The test method makes it possible to measure the heat flow through the thermal superinsulation over time and to investigate the degradation behaviour of the insulation within a test. In the paper results from the first tests are presented. T2 - 18th Cryogenics 2025, IIR Conference CY - Prague, Czech Republic DA - 07.04.2025 KW - LH2 KW - LNG KW - Fire KW - Insulation PY - 2025 AN - OPUS4-62979 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Harwege, Finn T1 - Testing of vacuum insulation panels for liquefied hydrogen storage tanks N2 - For the future use of liquefied hydrogen (LH2) as a green energy carrier, new concepts for storage tanks and in particular their insulation are necessary. The methodology applied in current LH2 tanks has some disadvantages while manufacturing and operation of large tanks that may be required in the future. While liquefied natural gas tanks exist in the necessary capacities, they are incompatible with LH2 due to its significantly lower storage temperature. In this paper, the possibility of using vacuum insulation panels (VIPs) as an alternative to the conventional double walled, powder filled vacuum insulation is presented. The two systems are introduced and compared on a conceptual level with a focus on the loss of vacuum failure mode. Furthermore, a test rig that enables the testing and quantification of thermal properties of VIP based insulations in ordinary and loss of vacuum conditions is presented. The test rig is a boil-off calorimeter using liquefied nitrogen and features a square cold surface with a side length of 2 m. An overview over the planned testing and its goals is given. T2 - 18th International Symposium on Loss Prevention and Safety Promotion in the Process Industries CY - Bologna, Italy DA - 08.06.2025 KW - Liquefied Hydrogen KW - LH2 KW - Cryogenics KW - Vacuum KW - Vacuum Insulation Panel PY - 2025 AN - OPUS4-63426 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Harwege, Finn T1 - Testing of vacuum insulation panels for liquid hydrogen storage tanks N2 - Vacuum insulation panel (VIP) based insulation could present an alternative to the common double walled vacuum insulation for large liquefied Hydrogen (LH2) storage tanks. In this paper a brief introduction on VIPs and the envisioned design of VIP-based LH2-tank insulation is given. The design of a flat plate boil-off calorimeter for the testing of the insulation concept is shown, with regard to thermal design, mechanical design and instrumentation. Finally, an overview over the particular challenges for modelling VIP-based insulation and the proposed testing to be performed on the test rig is presented. T2 - 18th Cryogenics IIR International Conference CY - Prague, Czech Republic DA - 07.04.2025 KW - Liquefied Hydrogen KW - Insulation KW - Calorimeter KW - LH2 KW - VIP KW - Vacuum Insulation Panel PY - 2025 AN - OPUS4-62988 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert T1 - New concepts in liquid hydrogen storage N2 - On the way to the energy transition, cryogenic fluids such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) are very important. They enable the large-scale economic transport and storage of energy as well as they represent alternative fuels for energy-intensive mobile applications such as aircrafts, ships and HGVs. For the last one, the number of vehicles and fuel stations has increased rapidly in the last 10 years all over Europe. Does this also entail new risks, for instance from a BLEVE in case of fires? To answer this question, BAM has conducted several research projects over the last decades and intensified the research recently with several experimental, numerical, and empirical outcomes on how a tank with insulation behaves in a fire. The presentation shows an overview of this research. The findings are relevant for global standardization procedures and to improve the overall safety in chemistry and technics. T2 - Hydrogen Refueling Station Opening CY - Baruth/Mark, Germany DA - 03.07.2025 KW - LH2 KW - Insulation KW - Fire KW - LNG KW - Safety PY - 2025 AN - OPUS4-63628 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eberwein, Robert A1 - Heßmann, Jennifer A1 - Werner, Jan A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Investigation of Realistic Fire Scenarios Involving Cryogenic Storage Tanks N2 - The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks for instance from a BLEVE? A key to answer this question is to research representative fires by its characterization and its effect on the insulation. At BAM’s technical test side in Germany, a test series was started to answer this question among others. This paper presents results on a pool fire under a colorimeter, that simulates a tank. The investigation points out, that the full fire characterization approach allows to represent the fire. The findings are relevant for the investigation of a representative design fire that is applicable for the approval and improvement of tanks as well as to research accident scenarios and their consequences. T2 - Loss Prevention 2025 CY - Bologna, Italien DA - 09.06.2025 KW - LH2 KW - LNG KW - Fire KW - Tank KW - Safety PY - 2025 DO - https://doi.org/10.3303/CET25116031 SN - 2283-9216 IS - 116 SP - 181 EP - 186 PB - AIDIC AN - OPUS4-63738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Theiler, Geraldine T1 - Comparative evaluation of the sliding performance of polymers materials in gaseous and liquid hydrogen N2 - The focus of this study is to evaluate the influence of hydrogen on the friction and wear behavior of a wide range of commercially available polymer materials. Thereby, Filled and unfilled polymers from different suppliers were evaluated at room temperature in air and hydrogen gas (H2) as well as in liquid hydrogen at - 253°C (LH2). T2 - 2023 Hydrogenius & I2CNER Tribology Symposium CY - Fukuoka, Japan DA - 03.02.2023 KW - Hydrogen KW - Tribology KW - Cryogenic KW - LH2 KW - Polymers PY - 2023 AN - OPUS4-61961 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Harwege, Finn A1 - Schmidt, Heiko A1 - Eberwein, Robert T1 - Testing of vacuum insulation panels for liquid hydrogen storage tanks N2 - Vacuum insulation panel (VIP) based insulation could present an alternative to the common double walled vacuum insulation for large liquefied Hydrogen (LH2) storage tanks. In this paper a brief introduction on VIPs and the envisioned design of VIP-based LH2-tank insulation is given. The design of a flat plate boil-off calorimeter for the testing of the insulation concept is shown, with regard to thermal design, mechanical design and instrumentation. Finally, an overview over the particular challenges for modelling VIP-based insulation and the proposed testing to be performed on the test rig is presented. T2 - 18th Cryogenics IIR International Conference CY - Prague, Czech Republic DA - 07.04.2025 KW - Liquefied Hydrogen KW - Insulation KW - Calorimeter KW - Vacuum Insulation Panel KW - LH2 PY - 2025 SN - 0151-1637 DO - https://doi.org/10.18462/iir.cryo.2025.0010 SN - 978-2-36215-053-1 VL - 2025 SP - 168 EP - 174 PB - ICCEX CY - Prag AN - OPUS4-62959 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sauer, Hannah A1 - Okpeke, Bright E. A1 - Dzielendziak, Agnieszka S. A1 - Eberwein, Robert A1 - Baetcke, Lars A1 - Ehlers, Sören T1 - Comparative life cycle assessment of vacuum insulation panel core materials for liquid hydrogen storage tanks – glass bubbles compared to conventional core materials N2 - The environmental performance of insulation materials for liquid hydrogen storage tank application is important to the development of sustainable supply chains. As new materials keep evolving, there is a need to assess their environmental impact. Therefore, this study investigates the environmental sustainability and circularity of cryogenic insulation concepts, namely vacuum insulation panels (VIPs), exclusively focussing on their core materials. Employing a cradle-to-grave life cycle assessment model, the VIP core materials are investigated with a special focus on glass bubbles. Based on the results, the global warming potential of the considered core materials, namely, glass bubbles, silica aerogel, fumed silica, expanded perlite, glass fibre, and polyurethane foam is 9.21∗10^−2, 7.00, 2.50∗10^−1, 3.63∗10^−2, 6.68∗10^−2, and 1.88 kg CO2 eq. per functional unit, respectively. In general, silica aerogel and polyurethane foam are the least environmentally friendly materials, while the most sustainable is expanded perlite, followed by glass fibre, glass bubbles, and fumed silica. KW - LH2 KW - Insulation KW - Cryogenic storage tank KW - Life Cycle Assessment PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-655445 DO - https://doi.org/10.1016/j.ijhydene.2026.153937 SN - 0360-3199 VL - 219 SP - 1 EP - 11 PB - Elsevier Ltd. AN - OPUS4-65544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -