TY - CONF A1 - Altenburg, Simon A1 - Maierhofer, Christiane A1 - Hilgenberg, Kai A1 - Mohr, Gunther A1 - Gumenyuk, Andrey A1 - Straße, Anne A1 - Pittner, Andreas A1 - Günster, Jens A1 - Gornushkin, Igor B. A1 - Pelkner, Matthias A1 - Ehlers, Henrik A1 - Heckel, Thomas A1 - Zscherpel, Uwe A1 - Seeger, Stefan A1 - Bruno, Giovanni T1 - ProMoAM - Verfahrensentwicklung für das Prozessmonitoring in der additiven Fertigung N2 - Verfahren zum in-situ Monitoring der Prozess- und Bauteilparameter sollen Fehlstellen und Inhomogenitäten bereits während der Fertigung nachweisen und zukünftig auch die Regelung der Prozessparameter ermöglichen. T2 - Challenges in Additive Manufacturing: Innovative Materials and Quality Control, Berlin Partner Workshop CY - Berlin, Germany DA - 12.09.2018 KW - Additive Fertigung KW - Prozessmonitoring KW - ProMoAM PY - 2018 AN - OPUS4-46300 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hernández García, María Amparo A1 - Rurack, Knut A1 - Bell, Jérémy A1 - Weller, Michael G. T1 - SAF-based optical biosensor with 3D-printed free-form optics for targeted explosives immuno-detection N2 - Guaranteeing safety and security of citizens requires a significant effort and innovative tools from national and international agencies and governments, especially when it comes to the field of explosives detection. The need to detect Improvised Explosive Devices (IEDs) and Home-made Explosives (HMEs) at a point of suspicion, has grown rapidly due to the ease with which the precursors can be obtained and the reagents synthesised. The limited availability of immunoanalytical tools for HME detection presents an opportunity for the development of new devices, which enable a rapid detection and recognise the target analyte with high specificity and sensitivity. In this work, we introduce an optical biosensor for highly specific and sensitive HME detection. The immunoassay system is placed in a hydrogel environment permeable to the analyte and transparent to light interrogating the fluorescently labelled antibodies. The readout of the immunoanalytical system is realized with Supercritical Angle Fluorescence (SAF), an advanced microscopy technique. To accomplish this, we made use of recent, commercial high resolution (< 22 µm) Liquid Crystal Display 3D printers to fabricate a parabolic optical element with high refractive index (RI>1.5) and transmission values (>90%) from photo-resin. Aiming at a new generation of sensors, which not only can meet the requirements of trace detection, but can also be used for substance identification, the combination of immunoanalytical recognition with SAF detection offers a modularity and versatility that is principally well suitable for the measurements of target analytes at trace levels. T2 - 8th International conference in Biosensing Technology CY - Seville, Spain DA - 12.05.2024 KW - 3D printing KW - Biosensor KW - Fluorescence KW - Explosives PY - 2024 AN - OPUS4-60561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hinsch, Alexandra A1 - Strelow, Christian A1 - Kipp, Tobias A1 - Würth, Christian A1 - Geißler, Daniel A1 - Resch-Genger, Ute A1 - Mews, Alf T1 - The influence of the individual Particles on the ensemble Quantum Yield of elongated CdSe/cds core/Shell nanoparticles N2 - Colloidal semiconductor nanoparticles with a spherical core and an elongated shell form bright emitters with a high absorption cross section. They show great potential for a multitude of optoelectronic applications such as LEDs or photovoltaic cells and can be used as gain material or as markers for bio imaging. For most of these applications high fluorescence quantum yields are a figure of merit for the emitter quality. In this work we investigate how the ensemble quantum yield is affected by the properties of the individual particles. In particular, we prove the role of non-emitting particles as well as the role of blinking. Using a combination of AFM and spatially resolved photoluminescence spectroscopy we measured hundreds of individual CdSe/CdS dot/rod particles of different shell lengths exciting with two different excitation wavelengths for shell or core excitation, respectively. T2 - SPIE Photonics West CY - San Francisco, CA, USA DA - 27.01.2018 KW - Exciton diffusion KW - Quantum Dot-Rod KW - Quantum Yield PY - 2018 AN - OPUS4-44759 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Geißler, Daniel A1 - Nirmalananthan-Budau, Nithiya A1 - Resch-Genger, Ute T1 - Preparation and characterization of reference particles for the calibration of flow cytometry for the detection of extracellular vesicles within the EMPIR project MetVes II N2 - Extracellular vesicles (EV) are cell-derived particles in body fluids, which have excellent potential as next-generation biomarkers. The exploitation of EV requires reliable measurements, which is currently very difficult, as most EV are smaller than 200 nm. At present, flow cytometry (FCM) is the most appropriate technique for EV analysis in biological samples, as FCM is readily available in many clinical laboratories and allows to identify cell-specific EV at high throughput. However, due to technical variations between different FCM instruments, EV concentration measurements are currently not well comparable between most laboratories. Therefore, EV reference materials and standardized reference methods are urgently needed to calibrate flow rate, light scattering intensity, and fluorescence intensity of FCM in the sub-micrometer size range. This requires a better matching of the optical properties of calibration beads and EV as can be realized with current polystyrene calibration beads. The EMPIR project 18HLT01 “MetVes II” aims to develop synthetic reference materials and traceable measurement methods to standardize EV measurements. The reference materials should resemble EV properties, so that calibrations are reliable and do not require a change of acquisition settings. Hence, the reference materials should contain particles with a traceable number concentration in the range of 109–1012 particles/mL to calibrate flow rate, a traceable size with discrete diameters between 50–1000 nm and a refractive index (RI) in the range of 1.37–1.42 to calibrate scattering intensity, and a traceable fluorescence intensity between 100–100,000 molecules of equivalent soluble fluorochromes (MESF). At BAM, various approaches to prepare such low-RI nanometer-sized reference materials will be studied, preliminary results of the primary characterization of these candidate reference particles will be presented, and possible applications besides FCM-based EV detection will be outlined. T2 - 29th Meeting of the German Society for Cytometry (DGfZ) CY - Berlin, Germany DA - 25.09.2019 KW - Extracellular vesicles (EV) KW - Flow cytometry KW - Reference particles KW - EMPIR project KW - 18HLT01 MetVes II PY - 2019 AN - OPUS4-50394 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Winckelmann, Alexander A1 - Hoffmann, V. A1 - Morcillo, Dalia A1 - Agudo Jácome, Leonardo A1 - Leonhardt, Robert A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique A1 - You, Zengchao T1 - Investigation of degradation of the aluminum current collector in lithium-ion batteries by glow-discharge optical emission spectroscopy N2 - Lithium-ion batteries (LIBs) are one technology to overcome the challenges of climate and energy crisis. They are widely used in electric vehicles, consumer electronics, or as storage for renewable energy sources. However, despite innovations in batteries' components like cathode and anode materials, separators, and electrolytes, the aging mechanism related to metallic aluminum current collector degradation causes a significant drop in their performance and prevents the durable use of LIBs. Glow-discharge optical emission spectroscopy (GD-OES) is a powerful method for depth-profiling of batteries' electrode materials. This work investigates aging-induced aluminum deposition on commercial lithium cobalt oxide (LCO) batteries' cathodes. The results illustrate the depth-resolved elemental distribution from the cathode surface to the current collector. An accumulation of aluminum is found on the cathode surface by GD-OES, consistent with results from energy-dispersive X-ray spectroscopy (EDX) combined with focused ion beam (FIB) cutting. In comparison to FIB-EDX, GD-OES allows a fast and manageable depth-profiling. Results from different positions on an aged cathode indicate an inhomogeneous aluminum film growth on the surface. The conclusions from these experiments can lead to a better understanding of the degradation of the aluminum current collector, thus leading to higher lifetimes of LIBs. T2 - Adlershofer Forschungsforum 2022 CY - Berlin, Germany DA - 11.11.2022 KW - Lithium Ion Batteries KW - GD-OES KW - FIB KW - SEM KW - EDX PY - 2022 AN - OPUS4-56246 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Winckelmann, Alexander A1 - Hoffmann, V. A1 - Morcillo, Dalia A1 - Agudo Jácome, Leonardo A1 - Leonhardt, Robert A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique T1 - Investigation of degradation of the aluminum current collector in lithium-ion batteries by glow-discharge optical emission spectroscopy N2 - Lithium-ion batteries (LIBs) are one technology to overcome the challenges of climate and energy crisis. They are widely used in electric vehicles, consumer electronics, or as storage for renewable energy sources. However, despite innovations in batteries' components like cathode and anode materials, separators, and electrolytes, the aging mechanism related to metallic aluminum current collector degradation causes a significant drop in their performance and prevents the durable use of LIBs.[1] Glow-discharge optical emission spectroscopy (GD-OES) is a powerful method for depth-profiling of batteries' electrode materials. This work investigates aging-induced aluminum deposition on commercial lithium cobalt oxide (LCO) batteries' cathodes. The results illustrate the depth-resolved elemental distribution from the cathode surface to the current collector. An accumulation of aluminum is found on the cathode surface by GD-OES, consistent with results from energy-dispersive X-ray spectroscopy (EDX) combined with focused ion beam (FIB) cutting. In comparison to FIB-EDX, GD-OES allows a fast and manageable depth-profiling. Results from different positions on an aged cathode indicate an inhomogeneous aluminum film growth on the surface. The conclusions from these experiments can lead to a better understanding of the degradation of the aluminum current collector, thus leading to higher lifetimes of LIBs. T2 - European Winter Conference on Plasma Spectrochemistry (EWCPS 2023) CY - Ljubljana, Slovenia DA - 29.01.2023 KW - Lithium-ion batteries KW - Aging mechanisms KW - Depth-profiling PY - 2023 AN - OPUS4-56992 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -