TY - CONF A1 - Resch-Genger, Ute T1 - Standardization of Flourescence Measurements in the UV/VIS/NIR/IR at BAM N2 - Photoluminescence techniques are amongst the most widely used tools in the life sciences, with new and exciting applications in medical diagnostics and molecular imaging continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. General drawbacks are, however, signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are also time-dependent due to aging of instrument-components, and difficulties to measure absolute fluorescence intensities. Moreover, scattering systems require special measurement geometries and the interest in new optical reporters with emission > 1000 nm strategies for reliable measurements in the second diagnostic for the comparison of material performance and the rational design of new fluorophores with improved properties. Here, we present strategies to versatile method-adaptable liquid and solid fluorescence standards for different fluorescence parameters. Examples are multi-emitter glasses, spectral fluorescence standards, and quantum yield standards for the UV/vis/NIR. T2 - Konsortiumtreffen Mikroskopie CY - Universität Münster, Germany DA - 20.01.2020 KW - Fluorescence standard KW - Instrument calibration KW - Integrating sphere spectroscopy KW - Fluorescence quantum yield KW - Fluorescent glasses KW - Fluorescence microscopy KW - Particle, imaging PY - 2020 AN - OPUS4-50308 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Instrument Calibration and Standardization of Fluorescence Measurements in the UV/vis/NIR/IR N2 - Comparison of fluorescence measurements performed on different fluorescence instruments, analyte quantification from fluorescence intensities as well as the determination of fluorescence quantum yields require instrument calibration and consideration of the wavelength-dependent instrument-specific quantities spectral photon flux reaching the sample and spectral responsivity. Here, we present guidelines and recommendations for the qualification of fluorescence instruments and introduce suitable chromophore-based reference materials. Moreover, the design concepts of the different BAM fluorescence standards are discussed. T2 - COST 2017 CY - Turku, Finland DA - 03.04.2017 KW - Fluorescence KW - Dye KW - Glass KW - Calibration KW - Fluorescence standard KW - Integrating sphere spectroscopy KW - Fluorescence quantum yield KW - Instrument qualification KW - Quality assurance KW - NIR KW - IR PY - 2017 AN - OPUS4-43174 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Biophotonics at BAM – From photophysics of fluorescent nanocrystals to surface group analysis with optical methods N2 - Optical spectroscopic studies of the influence of size, particle architecture, and surface chemistry of different types of photoluminescent nanocrystals with emission in the vis/NIR will be presented including semiconductor quantum dots and lanthanide-based upconversion nanoparticles. This will include the photophysics of these materials assessed with steady state and time-resolved fluorometry on the ensemble and single particle level and concepts for the quantification of surface groups at nanomaterials with optical methods using cleavable probes and catch-and-release assays. T2 - Fakultät der University of Ottawa CY - Ottawa, Canada DA - 10.12.18 KW - Photoluminescence KW - Quantum yield KW - Nanocrystal KW - Semiconductor quantum dot KW - Upconversion nanoparticle KW - Integrating sphere spectroscopy KW - Cleavable probe KW - Surface analysis KW - Ligand quantification PY - 2018 AN - OPUS4-47551 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Design, characterization and application of molecular and nanoscale optical reporters and probes and method standardization N2 - Here, we present an overview of the research activities of division Biophotonics concerning the design and (bio)analytical application of molecular and nanoscale functional chromophores for e.g., biomarker analysis including methods for the reliable determination of their application relevant properties. This includes the absolute determination of their brightness and photoluminescemce quantum yield, determining the signal size from the material side, as well as the development of fluorescence standards for such measurements and instrument calibration strategies, thereby providing important prerequisites for the comparison of material performance, the mechanistic understanding of nonradiative decay channels, and the rational design of new optical reporters. Moreover, for particle-based systems, ranging from nm-sized semiconductor quantum dots to m-sized polymeric and silica beads, simple optical methods and assays for the assessment of their surface chemistry are presented, which enable the quantification of the number of total and derivatizable surface functionalities, ligands per particle and particle-bound biomolecules. In addition, validation concepts for such methods are introduced utilizing method comparisons, multimodal and cleavable probes. T2 - Seminar Microbiology of Interfaces CY - Magdeburg, Germany DA - 16.06.2016 KW - Biomarker PY - 2016 AN - OPUS4-36997 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Effect of particle architecture, dopant concentration, size, and excitation power density on the luminescence efficiency of upconversion nanocrystals N2 - Lanthanide-based upconversion nanoparticles (UCNPs) offer new strategies for luminescence-based sensing and imaging. One of the best studied materials are hexagonal ß-NaYF4 UCNPs doped with 20% Yb3+ and 2% Er3+, which efficiently convert 976 nm light to photons emitted at 540 nm, 655 nm, and 845 nm, respectively, reveal Long luminescence lifetimes (> 100 µs), and are very photostable and chemically inters.[1,2] The properties of their upconversion (UC) luminescence (UCL) are, however, strongly influenced by particle size, concentration and spatial arrangement of dopant Ions, surface chemistry, and microenvironment.[3,4] In addition, the multiphotonic absorption processes responsible for UCL render UCL dependent on excitation power density (P). The rational design of brighter UCNPs particle architectures encouraged us to assess systematically the influence of these parameters on UCL for differently doped UCNPs relying on the commonly used ß-NaYf4 matrix using steady state and time resolved fluorometry as well as integrating sphere spectroscopy for P varied over almost three orders of magnitude. This includes comprehensive studies of the influence of size and shell, Yb3+ and Er3+ dopand concentrations, and energy Transfer processes from UCNPs to surface-bound organic dyes or vice versa [5]. Our results underline the need for really quantitative luminescence studies for mechanistic insights, the potential of high p to compensate for UCL surface quenching, and the matrix- and P-dependence of the optimum dopand concentration. T2 - BIOSPIE 2018 CY - San Francisco, USA DA - 27.01.2018 KW - Upconversion KW - Nanoparticle KW - Absolute fluorometry KW - Integrating sphere spectroscopy KW - NIR KW - IR KW - Fluorescence KW - Surface chemistry KW - Deactivation pathways KW - Modeling KW - Size PY - 2018 AN - OPUS4-43939 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Automated determination of genotoxicity of nanoparticles with DNA-based optical assays - The NANOGENOTOX project N2 - The overall interest in nanotoxicity, triggered by the increasing use of nanomaterials in the material and life sciences, and the synthesis of an ever increasing number of new functional nanoparticles calls for standardized test procedures1,2 and for efficient approaches to screen the potential genotoxicity of these materials. Aiming at the development of fast and easy to use, automated microscopic methods for the determination of the genotoxicity of different types of nanoparticles, we assess the potential of the fluorometric γH2AX assay for this purpose. This assay, which can be run on an automated microscopic detection system, relies on the detection of DNA double strand breaks as a sign for genotoxicity3. Here, we provide first results obtained with broadly used nanomaterials like CdSe/CdS and InP/ZnS quantum dots as well as iron oxide, gold, and polymer particles of different surface chemistry with previously tested colloidal stability and different cell lines like Hep-2 and 8E11 cells, which reveal a dependence of the genotoxicity on the chemical composition as well as the surface chemistry of these nanomaterials. These studies will be also used to establish nanomaterials as positive and negative genotoxicity controls or standards for assay performance validation for users of this fluorometric genotoxicity assay. In the future, after proper validation, this microscopic platform technology will be expanded to other typical toxicity assays. T2 - SPIE 2018 CY - San Francisco, USA DA - 27.01.2018 KW - Nanoparticle KW - Fluorescence KW - Surface chemistry KW - Size KW - Assay KW - Microscopy KW - Nanotoxicity KW - Toxicity KW - Automation KW - Calibration KW - Standard PY - 2018 AN - OPUS4-44186 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Methods for the calibration of fluorescence setups and measurement of photoluminescence quantum yields N2 - Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Generally recognized drawbacks, however, are signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are also time-dependent due to aging of instrument-components, and difficulties to measure absolute fluorescence intensities, thus rendering the use of intensity standards mandatory for quantification. Recent developments in fluorescence-based assays in clinical, pharmaceutical, biotechnological and other areas, in conjunction with the increasing need for instrument performance validation and global trends to harmonize measurements have boosted the demand for robust, easy-to-use, readily-available, reliable, and well documented fluorescence standards. This includes e.g. fluorescence standards for the consideration of instrument-specific spectral and intensity distortions of measured signals and instrument performance validation as well as fluorescence intensity standards for the quantification from measured intensities and for signal refencing, thereby accounting for excitation light-induced intensity fluctuations. Moreover, there is an ever increasing need for fluorescence quantum yield standards with well known and preferably certified quantum yields. Moreover, although already challenging for the UV/vis/NIR spectral region, there is an increasing interest particularly by the fluorescence imaging community to expand the waveelngth region applied from the NIR to measurements > 1000 nm. Presently, there are no fluorescence standards for this wavelength region available, rendering the control of instrument calibration in this wavelength region basically impossible. In this respect, we present reliable and validated procedures for the calibration of fluorescence measuring devices from 300 nm to 1700 nm using different types of physical and chemical standards. Moreover, a new set of fluorescence quantum yield standards covering the UV/vis/NIR is been introduced that is currently under certification at BAM. T2 - Arbeitskreis, Mass Spectrometry Facility CY - University of Berkeley, CA, USA DA - 13.02.2016 KW - pharmaceutical KW - biotechnological PY - 2016 AN - OPUS4-35842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radunz, Sebastian A1 - Kraus, Werner A1 - Bischoff, F. A. A1 - Emmerling, Franziska A1 - Resch-Genger, Ute A1 - Tschiche, Harald T1 - Temperature- and Structure-Dependent Optical Properties and Photophysics of BODIPY Dyes N2 - We report on the temperature- and structural-dependent optical properties and photophysics of a set of boron dipyrromethene (BODIPY) dyes with different substitution patterns of their meso-aryl subunit. Single-crystal Xray diffraction analysis of the compounds enabled a classification of the dyes into a sterically hindered and a unhindered group. The steric hindrance refers to a blocked rotational motion of the aryl subunit around the bond connecting this moiety to the meso-position of the BODIPY core. The energy barriers related to this rotation were simulated by DFT calculations. As follows from the relatively low rotational barrier calculated to about 17 kcal/mol, a free rotation is only possible for sterically unhindered compounds. Rotational barriers of more than 40 kcal/mol determined for the sterically hindered compounds suggest an effective freezing of the rotational motion in These molecules. With the aid of temperature-dependent spectroscopic measurements, we could show that the ability to rotate directly affects the optical properties of our set of BODIPY dyes. This accounts for the strong temperature dependence of the fluorescence of the sterically unhindered compounds which show a drastic decrease in fluorescence quantum yield and a significant shortening in fluorescence lifetime upon heating. The optical properties of the sterically hindered compounds, however, are barely affected by temperature. Our results suggest a nonradiative deactivation of the first excited singlet state of the sterically unhindered compounds caused by a conical intersection of the potential energy surfaces of the Ground and first excited state which is accessible by rotation of the meso-subunit. This is in good agreement with previously reported deactivation mechanisms. In addition, our results suggest the presence of a second nonradiative depopulation pathway of the first excited singlet state which is particularly relevant for the sterically hindered compounds. KW - Fluorescence KW - Sensor KW - Switch KW - pH KW - BODIPY KW - Dye KW - Probe KW - Synthesis KW - Photophysics KW - Mechanism PY - 2020 DO - https://doi.org/10.1021/acs.jpca.9b11859 SN - 1089-5639 VL - 124 IS - 9 SP - 1787 EP - 1797 PB - American Chemical Society AN - OPUS4-50639 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Otto, S. A1 - Moll, J. A1 - Förster, C. A1 - Geißler, Daniel A1 - Wang, Cui A1 - Resch-Genger, Ute A1 - Heinze, K. T1 - Three-in-One Crystal: The Coordination Diversity of Zinc Polypyridine Complexes N2 - The syntheses, structures, and photophysical properties of two new zinc(II) complexes bearing the tridentate N,N′-dimethyl-N,N′-dipyridin-2-ylpyridine-2,6-diamine (ddpd) ligand are presented. Structural investigations through single-crystal X-ray diffractometry, NMR spectroscopy, and density functional theory calculations revealed a diverse coordination behavior that depends on the counterion. Spectroscopic (UV/Vis and emission spectroscopy) and theoretical techniques (DFT and time-dependent DFT calculations) were employed to explore the photophysical properties of the complexes. KW - Zinc(II) complexes KW - X-ray diffractometry (XRD) KW - NMR spectroscopy KW - Density functional theory (DFT) KW - UV/Vis and emission spectroscopy PY - 2017 DO - https://doi.org/10.1002/ejic.201700948 SN - 1434-1948 SN - 1099-0682 VL - 43 SP - 5033 EP - 5040 PB - WILEY-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-43274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Resch-Genger, Ute ED - Martynenko, Irina ED - Baimuratov, A. S. ED - Osipova, V. A. ED - Kuznetsova, V. A. ED - Purcell-Milton, F. ED - Rukhlenko, I. D. ED - Fedorov, A. V. ED - Gun'ko, Y. K. ED - Baranov, A. V. T1 - Excitation energy dependence of the photoluminescence quantum yield of core/shell CdSe/CdS quantum dots and correlation with circular dichroism N2 - Quantum dot (QD) based nanomaterials are very promising materials for the fabrication of optoelectronic devices like solar cells, light emitting diodes (LEDs), and photodetectors as well as as reporters for chemo- and biosensing and bioimaging. Many of These applications involve the monitoring of changes in photoluminescence intensity and energy transfer processes which can strongly depend on excitation wavelength or energy. In this work, we analyzed the excitation energy dependence (EED) of the photoluminescence quantum yields (PL QYs) and decay kinetics and the circular dichroism (CD) spectra of CdSe/CdS core/shell QDs with different thicknesses of the surface passivation shell. Our results demonstrate a strong correlation between the spectral position of local maxima observed in the EED of PL QY and the zero-crossing points of the CD profiles. Theoretical analysis of the energy band structure of the QDs with effective mass approximation suggests that these structures could correspond to exciton energy levels. This underlines the potential of CD spectroscopy for the study of electronic energy structure of chiroptically active nanocrystals which reveal quantum confinement effects. KW - Fluorescence KW - Semiconductor KW - Nanoparticle KW - Surface chemistry KW - Quantum yield KW - Lifetime KW - Nanocrystal KW - Cysteine KW - Thiol KW - Ligand KW - Quantum dot KW - CdSe KW - Exciton KW - Circular dichroism KW - Theory KW - Excitation spectra KW - Excitation energy dependence PY - 2017 DO - https://doi.org/10.1021/acs.chemmater.7b04478 SN - 0897-4756 SN - 1520-5002 VL - 30 IS - 2 SP - 465 EP - 471 PB - ACS Publications AN - OPUS4-44034 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -