TY - CONF A1 - Aristia, Gabriela A1 - Bäßler, Ralph T1 - A Coating System for Corrosion Protection of Carbon Steel as an Alternative for High Alloyed Materials N2 - Corrosive geothermal brines are a major challenge to geothermal power-plants. For cost reasons, plant designers favorize low alloyed steels, e.g., carbon steel, which are susceptible to uniform and localized corrosion when exposed to geothermal brines having acidic and saline properties. To solve such problem, coatings or inhibitors would be a protective solution as an alternative to the use of high alloyed materials. This study investigated a coating system consisting of polyaniline/silicon dioxide basing on locally available resources. Protection against corrosion of carbon steel is shown by long-term exposure and electrochemical tests of coated carbon steels, performed in an artificial acidic and saline geothermal brine, comparable to real conditions at a site in Indonesia. Therefore, an integrated coating system is presented for corrosion protection, combining the electro-chemical functionality of polyaniline and the physical advantages of silica. T2 - European Geothermal Congress CY - Berlin, Germany DA - 17.10.22 KW - Corrosion KW - Geothermal KW - Coatings KW - Polyaniniline KW - Silicate PY - 2022 SP - 1 EP - 7 CY - Berlin AN - OPUS4-56085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pötzsch, Sina A1 - Weltschev, Margit A1 - Bäßler, Ralph T1 - Compatibility of polymers exposed to heating oil blends with 10 % and 20 % biodiesel (FAME) N2 - Biodiesel (FAME) from rapeseed is an environmentally friendly alternative to common fossil fuels. It is also suitable to serve as blending component to fuels like heating oil. If the fuel composition is changed, materials compatibility must be guaranteed. Adding polar biodiesel to nonpolar heating oil, changes the blend’s solvency and might cause swelling, extraction and solvation of polymers. The objective of this research was to investigate the compatibility of polymeric materials, which are commonly used for components in middle distillate facilities, along with blends of heating oil and 20 % biodiesel (B20). For this propose, ACM, HNBR, FKM, PE, PA 6, POM, PUR and PVC were exposed to heating oil and B20 for 42 and 84 days at 40 °C. In addition, the polymers HNBR, FKM, PA, POM and PVC were also exposed at 70 °C. Furthermore, the resistance of polymers in eight-year aged B10 at 40 °C was evaluated. Ageing of biodiesel increases acidity which might propagate polymer corrosion. The materials were evaluated as resistant, if the loss in tensile properties (tensile strength and elongation at break) and Shore hardness remained under 15 % compared to the initial unexposed material values. For investigations under compressed conditions, the compression set was determined for specimens of ACM, FKM and HNBR after exposure in heating oil B0 and B20 for 3,7,14, 28, 56 and 90 days at 40 °C according to ISO 815-1. It was found that the resistance in B20 at 40 °C was given for all tested polymers except PUR. In the 8 years aged B10, PUR and POM were not compatible and ACM just conditionally compatible. At 70 °C, FKM and PVC were resistant in B20, whereas HNBR and PA 6 were not compatible. Swelling occurred for the elastomers ACM, HNBR and PUR. T2 - AMPP Annual International Corrosion Conference 2021 CY - Online Meeting DA - 19.04.2021 KW - Biodiesel KW - FAME KW - RME KW - Polymer in fuels PY - 2021 SP - 16222-01 EP - 16222-12 CY - Houston AN - OPUS4-52499 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seifert, Lando A1 - Müller, Thoralf A1 - Ebell, Gino ED - Pillai, Radhakrishna G. T1 - Development of a new test method for assessing the susceptibility of prestressing steels to hydrogen-induced stress corrosion cracking N2 - For prestressing steel’s factory production control, approvals, and continuous surveillance in Germany, a susceptibility test against hydrogen-induced stress corrosion cracking is performed. The measured time to fracture results (in hours) must be reproducible and reliable in the test. ISO 15630-3 gives currently unpersuasive and diverging results using a free corrosion approach for hydrogen charging. A newly developed test method uses cathodic polarization for defined hydrogen charging instead of an uncontrolled and variable electron supply by metal dissolution during free corrosion. With this new test method, a reliable differentiation is possible between highly susceptible-known “old-type” quenched and tempered prestressing steel, i.e., Neptun, Hennigsdorfer, Sigma, and currently approved cold-drawn wires St 1470/1670 (CDS-1670) and St 1570/1770 (CDS-1770). The reproducibility of the new test method was evaluated in a round-robin test with eight attended testing institutes on a St 1470/1670 (CDS-1670) batch. T2 - Conference CONSEC24 CY - Chennai, India DA - 25.09.2024 KW - Hydrogen charging KW - ISO 15630-3 KW - Prestressing steels KW - Round-robin KW - Stress corrosion cracking PY - 2024 UR - https://consec24.com/# SP - 1 EP - 8 PB - Indian Institute of Technology (IIT) Madras, Centre of Excellence on Technologies for Low Carbon & Lean Construction CY - Chennai, India AN - OPUS4-61163 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Le, Quynh Hoa A1 - Bäßler, Ralph A1 - Bettge, Dirk T1 - Electrochemical behaviors of casing steel/mortar interface in CO2 saturated aquifer fluid N2 - To reveal the corrosion resistance of casing steel/mortar interface in CO2 injection condition, sandwich samples were prepared and exposed up to 20 weeks in aquifer fluid under 10 MPa and 60 °C. Cross section analysis revealed the crevice corrosion as main mechanism instead of pitting corrosion, which would be expected to happen in the extremely high Chloride concentration. Detailed analysis using EDS line scan shown the slow diffusion of Chloride, suggesting why pitting did not happen after 20 weeks. To mimic the passivated steel surface, the steel coupon was passivated in simulated pore solution having pH 13.5 for 42 days. The passivated coupon was further exposed to NGB solution for 28 days. Electrochemical characterization was performed along the exposure processes to reveal the change in impedance, indicating the corrosion resistance of steel casing/mortar interface. T2 - EUROCORR 2022 CY - Berlin, Germany DA - 28.08.2022 KW - Corrosion KW - CO2 quality KW - Pipeline network KW - CCS PY - 2022 SP - 859 EP - 865 PB - European Federation of Corrosion AN - OPUS4-55622 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bäßler, Ralph A1 - Stoljarova, A. A1 - Regenspurg, S. T1 - Influence Of Brine Precipitates On Materials Performance In Geothermal Applications N2 - Since geothermal wells are a feasible energy source to replace fossil fuel supply, many technologies have been developed to take advantage of geothermal energy. Nevertheless, service conditions in geothermal facilities are in many cases extreme in terms of corrosion due to the chemical composition of hydrothermal fluids and temperatures. Therefore, materials selection based on preliminary material qualification is essential to guarantee a secure and reliable operation of the facilities. During operation of a geothermal research facility in Groß Schönebeck copper and lead effects have been found downhole. Occurring mechanisms and measures to prevent precipitation or scaling needed to be investigated as well as potential influences of such precipitates on corrosion resistance of metallic materials used for equipment. This contribution deals with the evaluation of the corrosion behavior of carbon steel and corrosion resistant alloys in copper and/or lead containing artificial geothermal water, simulating the conditions in the Northern German Basin. The behavior of these materials in an artificial geothermal water obtained by electrochemical measurements and exposure tests are presented. While carbon steel exhibits precipitation and deposition, higher alloyed material shows different response to such species and a higher resistance in saline geothermal water. Basing on these results the suitability of the investigated corrosion resistant alloy is given for use in such conditions, whereas carbon steel creates difficulties due to its susceptibility to Cu- and Pb-precipitation. T2 - AMPP Annual 2023 Conference CY - Denver, CO, USA DA - 19.03.2023 KW - Geothermal KW - Electrochemistry KW - Copper KW - Lead KW - Corrosion PY - 2023 SP - 1 EP - 15 PB - AMPP CY - Houston TX USA AN - OPUS4-57233 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bäßler, Ralph A1 - Stoljarova, A. A1 - Regenspurg, S. T1 - Influence of Precipitating Brine Components on Materials Selection for Geothermal Applications N2 - Since geothermal wells are a feasible energy source to replace fossil fuel supply, many technologies have been developed to take advantage of geothermal energy. Nevertheless, service conditions in geothermal facilities are in many cases extreme in terms of corrosion due to the chemical composition of hydrothermal fluids and temperatures. Therefore, materials selection based on preliminary material qualification is essential to guarantee a secure and reliable operation of the facilities. During operation of a geothermal research facility in Groß Schönebeck copper and lead effects have been found downhole. Occurring mechanisms and measures to prevent precipitation or scaling needed to be investigated as well as potential influences of such precipitates on corrosion resistance of metallic materials used for equipment. This contribution deals with the evaluation of the corrosion behavior of carbon steel and corrosion resistant alloys in copper and/or lead containing artificial geothermal water, simulating the conditions in the Northern German Basin. The behavior of these materials in an artificial geothermal water obtained by electrochemical measurements and exposure tests are presented. While carbon steel exhibits precipitation and deposition, higher alloyed material shows different response to such species and a higher resistance in saline geothermal water. Basing on these results the suitability of the investigated corrosion resistant alloy is given for use in such conditions, whereas carbon steel creates difficulties due to its susceptibility to Cu- and Pb-precipitation. T2 - World Geothermal Congress CY - Online meeting DA - 30.03.2021 KW - Copper KW - Lead KW - Corrosion KW - Steel KW - Geothermal energy PY - 2021 SP - 1 EP - 11 AN - OPUS4-52828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bäßler, Ralph T1 - ISO 27913 - Example For Successful Standardization Activities In The Field Of CCUS N2 - Since 2016 ISO Technical Committee (TC) 265 is working on standardization the whole CCS-process chain. Around 30 countries are working together to provide international guidelines. As ISO 27913 was the first standard finished within these activities it is already in the stage of first revision. The objective of ISO 27913 is “to provide specific requirements and recommendations on certain aspects of safe and reliable design, construction and operation of pipelines intended for the large-scale transportation of CO2 that are not already covered in existing pipeline standards such as ISO 13623, ASME B31.8, EN 1594, AS 2885 or other standards. Existing pipeline standards cover many of the issues related to the design and construction of CO2 pipelines; however, there are some CO2 specific issues that are not adequately covered in these standards. The purpose of this document is to cover these issues consistently. Hence, this document is not a standalone standard, but is written to be a supplement to other existing pipeline standards for natural gas or liquids for both onshore and offshore pipelines.” This contribution shall provide information on the content, the current stage of the revision process, encourage to contribute to this standard and make listeners aware to consider the influence of ISO standard on documents currently in draft. T2 - AMPP's Annual Conference + Expo 2024 CY - New Orleans, LA, USA DA - 02.03.2024 KW - Corrosion resistant materials KW - Carbon dioxide KW - Corrosion prevention KW - Standardization KW - CCUS KW - CCS KW - CCU PY - 2024 SP - 1 EP - 6 PB - AMPP CY - Houston AN - OPUS4-59735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Thoralf A1 - Lehmann Schlag, Jens A1 - Burkert, Andreas T1 - KorroPad®-Ein Kurzzeitprüfverfahren zur Qualitätssicherung der Oberflächen- und Schweißnahtnachbearbeitung nichtrostender Stähle N2 - Die Ausbildung einer stabilen Passivschicht ist entscheidend für den Korrosionsschutz nichtrostender Stähle. KorroPad® bietet eine schnelle, zerstörungsfreie Bewertung der Passivschichtstabilität und ist seit 2025 als DIN 50024 genormt. Die Methode ermöglicht eine 15‑minütige Vor‑Ort‑Prüfung ohne Spezialwissen und schließt die Lücke zwischen teuren Laborverfahren und fehlender prozessbegleitender Qualitätssicherung. Der Beitrag beschreibt Funktionsprinzip, Anwendung sowie Beispiele aus der Oberflächen- und Schweißnahtbearbeitung. T2 - 43. Vortrags- und Diskussionstagung Werkstoffprüfung 2025 CY - Dresden, Germany DA - 26.11.2025 KW - KorroPad KW - Nichtrostender Stahl KW - Korrosion KW - Passivität PY - 2025 SN - 978-3-88355-454-9 VL - 43 SP - 1 EP - 7 PB - DGM Deutsche Gesellschaft für Materialkunde e.V. CY - Sankt Augustin AN - OPUS4-64933 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bäßler, Ralph A1 - Keserović, A. A1 - Sobetzki, J. A1 - Sarmiento-Klapper, H. A1 - Boduch, A. A1 - Aristia, G. A1 - Faes, W. A1 - Stoljarova, A. A1 - Zimmer, S. T1 - Metallene Werkstoffe in Geothermieanlagen - nicht nur aus Sicht der Korrosion N2 - Um Konstrukteuren und Nutzern geothermischer Anlagen grundlegende Informationen über die Korrosionsbeständigkeit zur Verfügung zu stellen, wurden verschiedene metallene Werkstoffe, darunter nichtrostende Duplex- und austenitische Stähle sowie eine Nickellegierung, in künstlichen Geothermalwässern, die die Bedingungen an verschiedenen Standorten mit geothermischem Potenzial simulieren, mit Hilfe von elektrochemischen und Langzeittests hinsichtlich ihrer Eignung bewertet. In hochsalinaren Umgebungen erwies sich Spaltkorrosion als der entscheidende Mechanismus. Die Nickellegierung zeigt eine ausgezeichnete Beständigkeit gegenüber Lochkorrosion. Abgesehen von ihren hohen Kosten eignet sie sich sehr gut für den Bau von Geothermieanlagen mit stark salzhaltigen Fluiden. Rostfreie Stähle und Duplexstähle weisen eine begrenzte Korrosionsbeständigkeit gegen Loch- und Spaltkorrosion auf. Daher sind sie für stark salzhaltige Fluide nicht geeignet. Der Superaustenit zeigt ein temperaturabhängiges Verhalten. In nichtsalinaren Umgebungen könnten niedriglegierte Stähle (neben den höherlegierten Werkstoffen) als Konstruktionsmaterial für Geothermieanlagen eingesetzt werden, sofern eine ausreichende Wandstärke des Materials berücksichtigt wird. Neben Korrosionsaspekten erwies sich auch die Ausfällung von Fluidbestandteilen als interessantes Thema. Beim Betrieb der Forschungsanlage in Groß Schönebeck wurden Kupfer- und Bleieffekte im Bohrloch festgestellt. Die auftretenden Mechanismen und Maßnahmen zur Verhinderung von Ausfällungen und Abscheidungen wurden ebenso untersucht, wie deren mögliche Einflüsse auf die Korrosionsbeständigkeit metallener Werkstoffe für Anlagenkomponenten. Der Beitrag beschreibt die Wechselwirkungen zwischen Geothermalwässern und Ausrüstungskomponenten. T2 - 57. Kraftwerktechnisches Kolloquium CY - Dresden, Germany DA - 07.10.2025 KW - Örtliche Korrosion KW - Edelstahl KW - Ni-Legierungen KW - Geothermie KW - Abscheidung PY - 2025 SN - 978-3-00-082651-1 SN - 978-3-00-082652-8 SP - 551 EP - 568 PB - IKS-Verlag CY - Freiberg AN - OPUS4-64320 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Aristia, Gabriela A1 - Nofz, Marianne A1 - Bäßler, Ralph A1 - Sojref, Regine A1 - Le, Quynh Hoa T1 - Preliminary Study on Al2O3 Sol-Gel Coating for Corrosion Protection of Martensitic Stainless Steel in Artificial Geothermal Water N2 - Al2O3 coatings are often used as protective layers on steels against electrochemical and high-temperature corrosion because they are chemically inert and stable at elevated temperatures. This study presents preliminary work on the possibilities of using Al2O3 sol-gel coatings for corrosion protection of martensitic stainless steels in geothermal environments. Al2O3 sol-gel coatings were applied on UNS S42000, which is known to be susceptible to uniform and localized corrosion. The coated steel specimens were then tested in two types of artificial geothermal water, which simulate the geothermal fluids found in Sibayak (SBY), Indonesia, and North German Basin (NGB), Germany, respectively. SBY has pH 4 and 1.5 g/L of chloride ions, whereas NGB has a pH of 6 and 166 g/L of chloride ions. All experiments were carried out in autoclaves at 150 °C and 1 MPa under the deaerated condition. Evaluations were performed by investigating the surface profiles of both uncoated and coated steels before and after the corrosion test using a Laser Scanning Microscope (LSM) and Scanning Electron Microscope (SEM). Finally, Electrochemical Impedance Spectroscopy (EIS) was performed to compare the corrosion resistance of Al2O3 coated steels in SBY and NGB solutions. It was observed from the corrosion test that Al2O3 coatings are more suitable for use in the geothermal water with a higher pH. T2 - AMPP Annual International Corrosion Conference 2021 CY - Online Meeting DA - 19.04.2021 KW - Protective coating KW - Sol-gel coating KW - Geothermal KW - Martensitic steel KW - Corrosion PY - 2021 SP - 16777-01 EP - 16777-12 CY - Houston AN - OPUS4-52501 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -