TY - RPRT A1 - Meggyes, Tamás A1 - Debreczeni, Ákos A1 - Reddy, Krishna R. A1 - Karri, Madhusudhana R. A1 - Riddler, Gordon P. A1 - Roehl, Karl Ernst A1 - Czurda, Kurt A1 - Sarsby, Robert W. A1 - Simon, Franz-Georg A1 - Biermann, Vera T1 - Sustainable environmental protection N2 - Permeable reactive barriers (PRBs) offer an alternative as opposed to more cost-intensive active methods for groundwater remediation, e.g. pump-and-treat. Long-term performance of PRBs, however, is crucial for the technology’s success. The paper summarises the results of long-term column experiments with elemental iron (Fe0) and hydroxyapatite (HAP) as reactive materials for the removal of uranium from groundwater. Good removal results have been achieved using elemental iron with possible reaction paths being reductive precipitation and adsorption on to corrosion products of Fe0. T3 - BAM Forschungsberichtreihe - 280 PY - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-1710 SN - 978-3-9811655-2-4 SN - 0938-5533 VL - 280 SP - 1 EP - 54 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Koch, Matthias A1 - Liebich, Almuth A1 - Win, Tin A1 - Nehls, Irene T1 - Certified Reference Materials for the determination of mineral oil hydrocarbons in water, soil and waste N2 - The international research project HYCREF, funded by the European Commission in the 5 th Framework programme, aimed to develop methods to prepare homogenous and stable water-, soiland waste reference materials contaminated with mineral oil hydrocarbons and to test certify the mineral oil content by gas chromatographic methods. As mineral oil products are important sources for environmental contaminations a high need exists for certified reference materials for their determination using the new gas chromatographic methods (soil: ISO/FDIS 16703, waste: ENpr 14039, water: ISO 9377-2). The experimental conditions and results for preparation and characterisation of a total of nine reference materials (3 water-, 3 soil- and 3 waste materials) are described and discussed. Target values for the reference materials were defined at the beginning of the project in order to have clear quality criteria, which could be compared with the achieved results at the end of the project. These target specifications were related to the maximum uncertainty from test certification exercises (< 5 % for soil/waste and < 10 % for water), the maximum inhomogeneity between bottles (< 3 %) and minimum requirements for stability (> 5 years for soil/waste and > 2 years for water). The feasibility studies showed that solid materials (soil, waste) could be prepared sufficiently homogenous and stable. The test certified values of the 6 solid materials comprise a wide range of mineral oil content from about 200-9000 mg/kg with expanded uncertainties between 5.7-13.1 % using a coverage factor k (k = 2). The development of new water reference materials –the so-called “spiking pills” for an offshore- and a land-based discharge water represents one of the most innovative aspects of the project. The spiking pill technology facilitates the application and storage and improves the material stability compared with aqueous materials. Additional to the preparation and test certification of the reference materials investigations on the analytical method for the determination of mineral oil hydrocarbons were performed. The results obtained in relation to the optimisation of analytical method (extraction procedure, sample pretreatment, clean-up and measurement) were provided to the respective working group of ISO/TC 190, ISO/TC 147 and CEN/TC 292 and were incorporated into the ongoing standardisation procedures. The new version of ISO/FDIS 16703 (July 2004) includes the improvements based on HYCREF results, for example the increase of the solvent/sample ratio, the removal of acetone from the organic extracts and the use of column technique instead of batch technique for clean-up. T3 - BAM Forschungsberichtreihe - 272 PY - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-1795 SN - 978-3-86509-363-9 SN - 0938-5533 VL - 272 SP - 1 EP - 92 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-179 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Klingelhöffer, Hellmuth A1 - Ledworuski, Siegmar A1 - Brookes, Stephan-Peter A1 - May, Thomas T1 - Computer controlled tensile testing according to EN 10002-1 Results of a comparison test programm to validate a proposal for an amendment of the standard N2 - Tensile testing according to EN 10002-1 is one of the basic mechanical tests to characterise the mechanical properties of metallic materials. This testing procedure has been regularly under development for many decades in order to modify and amend it and to bring it up to an up to date standard. Today tensile testing for quality control in metals manufacturing industry is routinely performed automatically with computer controlled testing machines. Due to economical needs of industry proposals were made by a European Standard Committee to amend the standard EN 10002-1. A European research project with the acronym TENSTAND was started to validate the proposed modifications of the tensile testing standard. The work package 4 of the project was to validate the machine control characteristics. A comparison test program was started with ten partners, 4 test piece geometries and 3 test parameters for 6 materials, partly with upper and lower yield strength and partly with 0.2 % proof strength to compare experimental results according to the proposal to modify the standard EN 10002-1. Initially testing in the strain control mode was introduced as well as switching of the control mode to crosshead control 1 and switching of the testing speed at appropriate points during the test. The comparison test was evaluated statistically and scientifically. The following conclusions were derived from the comparison test and summarised as recommendations to the standard committees. The scatter of the material properties were not significantly reduced by introducing the amended testing procedure. Few of the reasons for the continuously observed scattercan be identified as follows: The material properties are observed to be widely dependent on the testing speed. As a consequence the range for the allowed testing speed must be reduced. The closed loop control was not optimised sufficiently in some tests, the use of complicated testing machine software led to misinterpretation of software commands, individual testing equipment and implementation of the tensile testing procedure led also to scatter of the material properties which lay in a range of few percent. This is blurred by the inhomogeneity of the material. T3 - BAM Forschungsberichtreihe - 268 PY - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-1835 SN - 978-3-86509-318-3 SN - 0938-5533 VL - 268 SP - 1 EP - 44 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-183 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Beck, Uwe A1 - Fritz, Thomas A1 - Gamer, Nadja A1 - Wirth, Thomas T1 - VAMAS - Versailles Project on Advanced Materials and Standards N2 - Glühentladung optischer Ausstrahlungsspektroskopie (GDOES) wurde ursprünglich für die elementare Analyse von Größenmaterialien entwickelt. Mehrere Gruppen führten diese Methode zur Analyse von Anstrichen, Laienstapeln und dünnen Filmen durch. In den frühen Neunzigern wurde eine ISO-TC 201-Arbeitsgruppe gegründet, um Normen für alle Formen der Glühentladungsspektroskopie (GDS) zu entwickeln und die Fähigkeiten der Oberflächenchemikalien-Analyse zu beurteilen, insbesondere für die Tiefe von gestuften Systemen. Die Quantifizierung von Tiefenprofilen, d.h. die Umwandlung von Intensitäts-Zeit- Profilen in Konzentrierungs-Tiefen-Profile ist für dc-mode entwickelt worden. 1997 wurde ein VAMAS TWA 2 Vorschlag für ein Referenzanstrich für GD-OES Tiefe gemacht. Entsprechend dem VAMAS Beurteilungsverfahren wurde dieser Vorschlag 1998 mit einigen geringfügigen Änderungen genehmigt. T3 - BAM Forschungsberichtreihe - 242 PY - 2001 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-2083 SN - 978-3-89701-713-X SN - 0938-5533 VL - 242 SP - 1 EP - 64 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Brookes, Stephen Peter T1 - Thermo-mechanical fatigue behaviour of the near-γ-titanium aluminide alloy TNB-V5 under uniaxial and multiaxial loading N2 - Mit wachsendem Umweltbewusstsein und der allgemeinen Notwendigkeit, die Verwendung von fossilen Brennstoffen zu minimieren, steigt auch in der Industrie der Druck zur verstärkten Anwendung von effizienteren Gasturbinentriebwerken. Die intermetallische Gamma- Titanaluminide (γ-TiAl) Legierung ist ein Material, welches die Effizienz von Gasturbinen steigern kann. Bei diesem Werkstoff handelt es sich um eine relativ neue Entwicklung, der sich durch geringe Dichte und hohe Festigkeit bei hoher Temperatur auszeichnet und damit das Potenzial hat, die heute verwendeten Ni-Basis-Superlegierungen zu ersetzen. Bauteile in Fluggasturbinen sind üblicherweise variierenden, mehrachsigen Spannungszuständen sowie nicht isothermen Zuständen unterworfen. Turbinenschaufeln sind z. B. vornehmlich dreiachsiger thermo-mechanischer Ermüdung (TMF) ausgesetzt. Dies erfordert eine sorgfältige Charakterisierung des zyklischen Verformungs- und Ermüdungsverhaltens unter komplexen thermischen und mechanischen Belastungen von γ-TiAl. Die vorliegende Arbeit untersucht die Wirkungen, die diese multi-axialen Beanspruchungen, auf eine γ-TiAl, (Ti -45 Al -5 N.B. -0,2 B -0,2 C) Legierung unter thermo-mechanischer Ermüdung haben. Das einachsige, torsions- und axial-torsionale thermo-mechanische Ermüdungsverhalten dieser γ-TiAl Legierung ist bei 400 – 800oC mit Dehnungsamplituden von 0,15% zu 0,7% geprüft worden. Die Tests wurden an beiden thermo-mechanischen Phasen, in-phase (IP) und out-of- phase (OP), durchgeführt und ausgewählte Tests enthielten außerdem eine Haltezeit von 180 Sekunde. Die Lebensdauer hängt stark von der Dehnungsamplitude ab. Ein-achsige Versuche unter IP Bedingungen zeigten bei gleicher mechanischer Dehnung eine längere Lebensdauer als Versuche unter OP-Bedingungen. Unter rein torsionaler Belastung zeigten die Proben bei der gleichen Vergleichsspannungsamplitude eine längere Lebensdauer als in axialen OPVersuchen. Bei nicht-proportionaler axial-torsionaler und thermo-mechanischer OP Versuchsführung ist die Lebensdauer bei gleicher mechanischer Vergleichsdehnungsamplitude geringer als bei ein- achsiger OP-Belastung. Die Wirkungen von TMF auf die Mikrostruktur wurden auch untersucht. Für alle Arten von Tests ist interkristalliner Bruch überwiegend. Ausfallschäden am Material sind stark von Umweltbedingungen beeinflusst. Diese Studie vergleicht Ergebnisse von TMF von TiAl mit vorherigen TMF Untersuchungen von Ni-Basislegierungen, IN 738 und Nimonic 90. IN 738 zeigt ein ähnliches thermomechanisches Verhalten wie γ-TiAl, indem es bei ein-achsiger IP Belastung die längste Lebensdauer hat. Nimonic 90 zeigt ein entgegengesetztes Verhalten im Vergleich zu IN 738 und γ-TiAl. Ein Lebensdauermodell, das für diese near-γ-TiAl Legierung entwickelt wurde, beschreibt erfolgreich alle Dehnungs-Temperatur-Pfade, d. h. das thermo-mechanische Ermüdungs- verhalten im Bereich der Testtemperaturen bei Verwendung eines einzelnen Belastungs- parameters. Der Belastungsparameter basiert auf der plastischen Arbeit pro Zyklus und ist abhängig nicht nur von der von Misesspannung sondern von der mittlern Zugspannung und von der maximalen Hauptspannung. Dieser Belastungsparameter reagiert dann auf verschiedene Dehnungs-Temperatur-Pfade unterschiedlich. Das Modell beschreibt das Lebensdauerverhalten einschließlich der einachsigen IP und OP, der proportional-axial-torsionalen und nicht- proportional axial-torsionalen Beanspruchungspfade, und den Einfluss der Haltezeit. N2 - With increasing environmental awareness and the general need to economise on the use of fossil fuels, there is growing pressure for industry to produce lighter, more efficient, gas turbine engines. One such material that will help to achieve these improvements is the intermetallic gamma titanium aluminide (γ-TiAl) alloy. At only half the density of current nickel-based superalloys its weight saving capability is highly desirable, however, its mechanical properties have not yet been fully explored especially, when it is to be considered for structural components in aeronautical gas turbine engines. Critical components in these engines typically experience large variations in temperatures and multiaxial states of stress under non-isothermal conditions. These stress states are known as tri-axial thermo-mechanical fatigue (TMF). The work presented here investigates the effects these multi-axial stresses, have on a γ- TiAl, (Ti-45Al-5Nb-0.2B-0.2C) alloy under TMF conditions. The uniaxial, torsional and xialtorsional TMF behaviour of this γ-TiAl alloy have been examined at 400 – 800oC with strain amplitudes ranging from 0.15% to 0.7%. The tests were conducted at both thermomechanical in-phase (IP) and out-of-phase (OP). Selected tests additionally contained a 180 seconds hold period. Fatigue lifetimes are strongly influenced by the strain amplitude, a small increase in amplitude reduces the lifetime considerably. The uniaxial IP tests showed significantly longer fatigue lifetimes than of all the tests performed. Torsional loading although have shorter fatigue lifetimes than the uniaxial IP loading they have longer fatigue lifetimes than the uniaxial OP loading. The non-proportional axial-torsional 90 degree OP test is most damaging which resulted in a shorter lifetime than the uniaxial OP test with the same Mises equivalent mechanical strain amplitude. A hold period at maximum temperatures reduced the lifetime for all tests regardless of the temperature-strain history. The effects of TMF on the microstructure were also investigated. For all types of tests intergranular fracture is predominant. Failure is strongly influenced by environmental conditions. This study compares TMF results of TiAl with previous TMF investigations on the nickelbased alloys IN 738 and Nimonic 90. IN 738 shows similar TMF behaviour to γ-TiAl in that uniaxial IP loading has the longest fatigue lifetimes. Nimonic 90 shows the opposite behaviour to both of these alloys. A lifetime model developed for this near-γ-TiAl alloy, successfully describes all temperaturestrain TMF loading conditions over the test temperature range, with the use of a single loading parameter. The loading parameter is based on the plastic work per cycle, and is not only dependant on the mean tensile stress but also on the maximum principal stress. The loading parameter responds to various strain-temperature-paths differently. It describes the lifetime relation between uniaxial IP and OP loading, axial and torsional loading and the hold period effect. T3 - BAM Dissertationsreihe - 49 KW - Gamma-Titanaluminide KW - Multi-axiale Beanspruchung KW - TNB-V5 KW - thermomechanische Ermüdung (TMF) KW - thermo-mechanical fatigue (TMF) KW - Gamma titanium aluminide KW - axial-torsional loading PY - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-1095 SN - 978-3-9812910-5-6 SN - 1613-4249 VL - 49 SP - 1 EP - 144 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-109 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Schempp, Philipp T1 - Grain refinement in aluminium GTA welds N2 - Grain refinement is an important opportunity to improve mechanical properties of fusion welds and the weldability (cracking sensitivity) of the base metal. In this thesis, grain refinement was achieved for aluminium welds by additions of a grain refiner. For this purpose, inserts consisting of aluminium base metal and small additions of commercial Al Ti5B1 grain refiner were cast, deposited in base metal plates, and fused in a gas tungsten arc (GTA) welding process. As a result, higher grain refiner additions increased the weld’s titanium and boron content resulting in a significant decrease in the weld metal mean grain size up to 86%. This grain size reduction led to a transition from predominantly columnar to equiaxed grain shape (columnar to equiaxed transition CET). The grain refinement was thereby found to be strongly dependent upon the base metal chemical composition. Accordingly, the grain refining efficiency was the highest in commercial pure Al (Alloy 1050A, Al 99.5), followed by Alloy 6082 (Al Si1MgMn) and Alloy 5083 (Al Mg4.5Mn0.7). In this regard, the parameters P and Q were applied to investigate the influence of alloying elements on the supply of constitutional undercooling during solidification and on final grain size. Also, WDS (wavelength dispersive x-ray spectroscopy) and TEM (transmission electron microscopy) analysis found an increasing number of particles rich in Ti and B. These substrates are probably TiB2 particles coated by Al3Ti likely nucleating Al grains during solidification. The variation in torch speed showed that increasing torch speeds support the CET effect leading to many small and equiaxed grains at high torch speed. To give explanations for this observation, the thermal conditions, that are controlled by welding parameters such as torch speed, were determined with temperature measurements via thermocouples. These measurements revealed that solidification parameters like solidification growth rate, cooling rate, (local) thermal gradient and solidification time vary significantly along the solidification front (from weld centreline to weld fusion line). In a further step, the solidification parameters were related to the corresponding grain size and shape. On the basis of this comparison, an analytical approach was used to model the CET. This allowed the prediction of critical values for both solidification growth rate and thermal gradient, at which the CET occurs in aluminium weld metal. The influence of grain refinement on the weld mechanical properties was investigated in tensile tests. Accordingly, the ductility of Alloy 5083 welds was increased through grain refinement whereas no improvement in weld metal strength was observed. Furthermore, tear tests with notched specimens revealed for Alloy 1050A that the resistance against initiation and propagation of cracks in the weld metal can be enhanced through grain refinement. In addition, when welding Alloy 6082, weld metal grain refinement prevented the formation of centreline solidification cracking that was present only in welds with unrefined grain structure. On the basis of the above experiments, the Ti/B contents needed in commercial filler wires or rods to allow optimum weld metal grain refinement were estimated. Accordingly, this work gives specific recommendations to filler material producers through a simple calculation that considers the influence of base alloy and welding process. The results show that the Ti/B contents defined by the corresponding standards for filler alloys are too low to allow weld metal grain refinement. T3 - BAM Dissertationsreihe - 111 KW - Aluminium KW - Kornfeinung KW - WIG-Schweißen PY - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-477 SN - 978-3-9815944-4-7 SN - 1613-4249 VL - 111 SP - 1 EP - 121 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-47 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Perret, William T1 - Welding Simulation of Complex Automotive Welded Assembly - Possibilities and Limits of the Application of Analytical Temperature Field Solutions N2 - Before the development of computational science, heat conduction problems were mainly solved by analytical techniques. Analytical solutions are exact solutions of differential equations; the investigated physical phenomena, for instance the temperature, are solved locally for one single point independently of the rest of the investigated structure resulting in extremely short computational times. These analytical solutions are however only valid for some simple geometries and boundary conditions making their applications for complex industrial geometries directly not possible. Numerical techniques, such as the Finite Element Method, enable overcoming this problem. However, the numerical simulation of the structural heat effect of welding for complex and large assemblies requires high computational effort and time. Therefore, the wide application of welding simulation in industry is not established, yet. The aim of this study is to combine the advantages of analytical and numerical simulation methods to accelerate the calibration of the thermal model of structure welding simulation. This is done firstly by calibrating automatically the simulation model with a fast analytical temperature field solution and secondly by solving the welding simulation problem numerically with the analytically calibrated input parameters. In order to achieve this goal, the analytical solution of the heat conduction problem for a point source moving in an infinite solid was extended and validated against reference models until a solution for a volumetric heat source moving on a thin small sheet with several arbitrary curved welding paths was found. The potential of this analytical solution by means of computational time was subsequently demonstrated on a semi-industrial geometry with large dimensions and several curved welds. The combined method was then transferred to an industrial assembly welded with four parallel welds. For this joint geometry, it was possible to apply the extended analytical solution. The calibration of the simulation model was done automatically against experimental data by combining the extended fast analytical solution with a global optimisation algorithm. For this calibration, more than 3000 direct simulations were required which run in less computational time than one corresponding single numerical simulation. The results of the numerical simulation executed with the analytically calibrated input parameters matched the experimental data within a scatter band of ± 10 %. The limit of the combined method is shown for an industrial assembly welded with eight overlap welds. For this joint geometry, a conventional numerical approach was applied, since no analytical solution was actually available. The final simulation results matched the experimental data within a scatter band of ± 10 %. The results of this work provide a comprehensive method to accelerate the calibration of the thermal model of the structure welding simulation of complex and large welded assemblies, even though within limitation. In the future, the implementation of this method in a welding simulation tool accessible to a typical industrial user still has to be done. T3 - BAM Dissertationsreihe - 108 KW - Schweißen KW - industrielle Anwendung KW - Simulation KW - analytische Lösung KW - komplexe Geometrie PY - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-505 SN - 978-3-9815944-0-9 SN - 1613-4249 VL - 108 SP - 1 EP - 183 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-50 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Gaal, Mate T1 - Trial Design for Testing and Evaluation in Humanitarian Mine Clearance N2 - This thesis proposes a design of experiment for testing and evaluation of the equipment and the methods used in manual mine clearance. The thesis is based on several metal detector trials and a trial of manual demining methods. The core of this dissertation comprises four metal detector trials performed in Germany and Croatian in 2003 and 2005. The purpose of these trials was to investigate the feasibility of the tests described in the CWA (Comité Européende Normalisation/CEN/Workshop Agreement) 14747:2003, the standard for testing metal detectors for humanitarian demining. The goals of the trials were: to find an appropriate design of experiment for testing metal detectors; to establish the use of ROC diagrams (Receiver Operating Characteristics) and POD curves (Probability of Detection) in the analysis of the experimental results; and to gain practical experience in organising and conducting metal detector trials. Apart of this thesis is devoted to a trial of manual demining methods performed in Mozambique in 2004. The main goal of that trial was to compare the speed of various manual demining methods, including the most common excavation methods. The outcome of this work is the proposals and recommendations for an update of the standard for testing metal detectors CWA 14747:2003. Maximum detection height measurements were performed as a part of the metal detector trial carried out in Croatiain2005. The results reveal a high variability of the maximum detection height. This high variability needs to be taken into account in all experiments. Apart of the variability is caused by the differences between the operators and by the setup of the metal detector. It is therefore recommended that two kinds of experiments with the maximum detection height as a response variable are defined in the next update of CWA 14747:2003. The first kind should include the setup, the soil and the operator as factors in the design of experiment. The in-soil measurements with the same detector should be performed with repeated setups and with several operators. The second kind of experiments should be experiments evaluating the influence of other predictor variables. In those experiments, it is recommended to perform one-factor or multiple-factor in-air measurements with the operators and the setup as a block. The main part of the metal detector trials described in this thesis was the detection reliability tests. Detection reliability tests as described in CWA14747:2003 come closest to representing the real field conditions in demining. They include many environmental influences and, most importantly, many of the human factor influences. However, each test design is a compromise between fully representative conditions and cost effectiveness. In this thesis, a fractional factorial design based on the Graeco-Latin square is proposed as a solution to the experimental problem. The results are reported in the form of ROC diagrams and POD curves. The crossover design enables each operator to work with fewer detector models with in a certain time. The variations of the design enabled an unbiased comparison of detectors in each soil and with each target model separately. It is recommended that the solutions proposed in this thesis be incorporated in the standard CWA14747:2003. It has been shown that maximum detection heights measurements provide the information about the best possible performance of a metal detector in are liability test. T3 - BAM Dissertationsreihe - 27 KW - Minenräumung KW - demining KW - Metalldetektor KW - metal detector PY - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-1310 SN - 978-3-9811655-6-2 SN - 1613-4249 VL - 27 SP - 1 EP - 158 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Alekseychuk, Oleksandr T1 - Detection of crack-like indications in digital radiography by global optimisation of a probabilistic estimation function N2 - A new algorithm for detection of longitudinal crack-like indications in radiographic images is developed in this work. Conventional local detection techniques give unsatisfactory results for this task due to the low signal to noise ratio (SNR ~ 1) of crack-like indications in radiographic images. The usage of global features of crack-like indications provides the necessary noise resistance, but this is connected with prohibitive computational complexities of detection and difficulties in a formal description of the indication shape. Conventionally, the excessive computational complexity of the solution is reduced by usage of heuristics. The heuristics to be used, are selected on a trial and error basis, are problem dependent and do not guarantee the optimal solution. Not following this way is a distinctive feature of the algorithm developed here. Instead, a global characteristic of crack-like indication (the estimation function) is used, whose maximum in the space of all possible positions, lengths and shapes can be found exactly, i.e. without any heuristics. The proposed estimation function is defined as a sum of a posteriori information gains about hypothesis of indication presence in each point along the whole hypothetical indication. The gain in the information about hypothesis of indication presence results from the analysis of the underlying image in the local area. Such an estimation function is theoretically justified and exhibits a desirable behaviour on changing signals. The developed algorithm is implemented in the C++ programming language and testet on synthetic as well as on real images. It delivers good results (high correct detection rate by given false alarm rate) which are comparable to the performance of trained human inspectors. N2 - In dieser Arbeit wurde ein neuer Algorithmus zur Detektion rissartiger Anzeigen in der digitalen Radiographie entwickelt. Klassische lokale Detektionsmethoden versagen wegen des geringen Signal-Rausch-Verhältnisses (von ca. 1) der Rissanzeigen in den Radiographien. Die notwendige Resistenz gegen Rauschen wird durch die Benutzung von globalen Merkmalen dieser Anzeigen erzielt. Das ist aber mit einem undurchführbaren Rechenaufwand sowie Problemen bei der formalen Beschreibung der Rissform verbunden. Üblicherweise wird ein übermäßiger Rechenaufwand bei der Lösung vergleichbarer Probleme durch Anwendung von Heuristisken reduziert. Dazu benutzte Heuristiken werden mit der Versuchs-und-Irrtums-Methode ermittelt, sind stark problemangepasst und können die optimale Lösung nicht garantieren. Das Besondere dieser Arbeit ist anderer Lösungsansatz, der jegliche Heuristik bei der Suche nach Rissanzeigen vermeidet. Ein globales wahrscheinlichkeitstheoretisches Merkmal, hier Schätzfunktion genannt, wird konstruiert, dessen Maximum unter allen möglichen Formen, Längen und Positionen der Rissanzeige exakt (d.h. ohne Einsatz jeglicher Heuristik) gefunden werden kann. Diese Schätzfunktion wird als die Summe des a posteriori Informationsgewinns bezüglich des Vorhandenseins eines Risses im jeden Punkt entlang der hypothetischen Rissanzeige definiert. Der Informationsgewinn entsteht durch die Überprüfung der Hypothese der Rissanwesenheit anhand der vorhandenen Bildinformation. Eine so definierte Schätzfunktion ist theoretisch gerechtfertigt und besitzt die gewünschten Eigenschaften bei wechselnder Anzeigenintensität. Der Algorithmus wurde in der Programmiersprache C++ implementiert. Seine Detektionseigenschaften wurden sowohl mit simulierten als auch mit realen Bildern untersucht. Der Algorithmus liefert gute Ergenbise (hohe Detektionsrate bei einer vorgegebenen Fehlalarmrate), die jeweils vergleichbar mit den Ergebnissen trainierter menschlicher Auswerter sind. T3 - BAM Dissertationsreihe - 18 KW - object detection KW - detection of elongated objects in low SNR condition KW - dynamic programming PY - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-1400 SN - 978-3-86509-534-8 SN - 1613-4249 VL - 18 SP - 1 EP - 114 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-140 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Mishra, Kirti Bhushan T1 - Experimental investigation and CFD simulation of organic peroxide pool fires (TBPB and TBPEH) N2 - Time averaged mass burning rate (m˙′′f ), flame length (H), temperature (T ), irradi- ance (E) and surface emissive power (SEP ) of TBPB (tert -butyl peroxybenzoate) and TBPEH (tert-butyl peroxy-2-ethylhexanoate) pool fires are measured for six pool di- ameters (d = 0.059 m, 0.107 m, 0.18 m, 0.5 m, 1 m and 3.4 m) at BAM in house and outside test facility. The measured heats of combustion (–Δhc) of TBPB and TBPEH are 30113 kJ/kg and 34455 kJ/kg and the specific heat capacities at constant pressure (cp) are 1.8 kJ/(kg K) and 2.1 kJ/(kg K) respectively. The measured m˙′′f of TBPB and TBPEH pool fires are in the range of 0.37 kg/(m2 s)≤ m˙ ′′ f ≤ 0.83 kg/(m2 s) and show little dependence on the pool diameter d, and are four to sixty times higher (for d = 1 m) than that of hydrocarbon pool fires. It is shown that the mass burning rates of the investigated organic peroxides can be represented as an exponential function of the self-accelerating decomposition temperature (SADT). Low SADT implies that the organic peroxide pool fires burn at a much higher m˙′′f than hydrocarbon pool fires. Fuel Froude numbers (Frf) of TBPB and TBPEH are 5 to 100 times (depending on d) higher than for hydrocarbon pool fires. Due to higher Frf the H of TBPB and TBPEH (measured with a S-VHS Videocamera) are found to be two times larger (d = 1 m) than corresponding pool fires of hydrocarbons. Heskestads flame length correlation predicts the Hd (d = 3.4 m) of TBPB and TBPEH pool fires much better than Thomas and Fay correlations. The measured time averaged flame temperatures T (d = 3.4 m) for TBPB and TBPEH pool fires are in the range of 1400 K ≤ T ≤ 1500 K and are 200 K to 300 K higher than for JP-4, kerosene and gasoline. The irradiances of the TBPB and TBPEH pool fires measured by radiometers are E (Δy/d = 0.3) = 45 kW/m2 and E = 98 kW/m2 which are two to ten times higher in comparison to the corresponding n-pentane, super gasoline and diesel pool fires. So the thermal safety distances for organic peroxide pool fires are larger by a factor four in comparison to the hydrocarbon pool fires. An infrared thermography system is used for the determination of SEP of TBPB and TBPEH pool fires. The values of surface emissive power for TBPB and TBPEH are SEP (d = 3.4 m) = 196 kW/m2 and SEP = 258 kW/m2 and thus the SEP are by a factor of approximately two higher than for hydrocarbon pool fires. A self-sustained pulsating Hd (’W’-Effect) is found in TBPB pool flames and is further analysed to explain the reason of occurance on the basis of chemical structure of the fuel and discontinuous heat flux back from flame to the liquid pool. CFD simulations of TBPB and TBPEH pool fires at d = 0.18 m, 0.5 m, 1 m, 3.4 m and 8 m are carried out using the Unsteady Reynolds Averaged Navier Stokes (URANS) equa- tions. The three-dimensional geometries have been discritized with unstructured hybrid grids, with the number of cells in the range of 1 million. Depending on the grid resolu- tion and the pool diameter time steps of 0.0001 s ≤ Δt ≤ 0.01 s for the CFD simulations are used. For solving the discritized equations a finite volume based implicit solver AN- SYS CFX has been used. For modelling the combustion, stoichiometric combustion for both peroxides are assumed. The temperature dependence of the reaction rate has been determined by the Arrhenius approach. For modelling the combustion eddy dissipation concept (EDC) model has been used. For turbulence buoyancy modified k- � and SAS (Scale Adaptive Simulation) turbulence models are used. For the thermal radiation and soot mass fraction discrete transfer radiation model and Magnusson soot model have been used. A new method is suggested for the prediction of mass burning rate (m˙′′f ) by CFD simula- tion. Both peroxide pool fires show approximately constant mass burning rate indepen- dent of d whereas m˙′′f of TBPEH are under predicted at the beginning but show relatively good agreement with measurements for large pool diameters (d = 1 m). In case of TBPB the CFD simulation over predicts the mass burning rate m˙′′f of small TBPB pool fires and shows a continuous decrease with d. CFD predicts the flame length H close to the measured data provided that the constants in Thomas equation are modified. The CFD predicted time averaged surface emission flame temperatures of TBPB and TBPEH pool fires (d = 3.4 m, 1437 K and 1542 K) are in good agreement with the measured time averaged flame temperatures. The CFD predicted SEP for TBPB and TBPEH pool fires (d = 3.4 m, 217 kW/m2 and 288 kW/m2) are also in agreement with the measured values. From the CFD predicted irradiance ECFD it is possible to determine the thermal safety distances from large pool fires of hydrocarbons and organic peroxides. T3 - BAM Dissertationsreihe - 63 KW - Pool fires KW - organic peroxides flame characteristics KW - safety distance KW - CFD simulation PY - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-950 SN - 978-3-9813550-6-2 SN - 1613-4249 VL - 63 SP - 1 EP - 150 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-95 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -