TY - CONF A1 - Sameith, Janin A1 - Schwibbert, Karin A1 - Tschiche, Harald A1 - Epperlein, Nadja A1 - Menzel, Friederike A1 - Hoffmann, Katrin A1 - Krüger, Jörg A1 - Resch-Genger, Ute A1 - Kunte, Hans-Jörg T1 - Microbially induced corrosion development of new analytical tools to study biofilm formation and corrosion processes N2 - Microbially induced corrosion (MIC) is a severe cost and risk factor for the oil and gas industry, water heat- and cooling systems, waste water management, and infrastructural constructions. The industrial preventions management of MIC focuses on eliminating present microorganisms, which leads to the repeated and time-consuming application of biocides. However, biocides are often only minor effective for microorganisms that live protected from these agents in a biofilm matrix formed on material surfaces. In recent years, microbiologist have renewed our vision on the electrochemical processes underlying material corrosion induced by sulfate reducing bacteria, but the knowledge at the level of multispecies biofilm formation and the effects of material’s properties are still rather scarce. Therefore, an interdisciplinary team of material scientists, chemists and microbiologists, established a MIC-research platform at the Federal Institute for Materials Research and Testing (BAM) to study the effects of material’s properties and biofilm formation on MIC. Using femtosecond laser pulse technology steel surfaces with defined nanostructures were manufactured. The test pieces were incubated using a flow-through chambers setup with different organisms relevant for biofilm studies. Our studies showed, that nanoscale structures severely affect the biofilm thickness and, hence, growth for health threatening organisms like E. coli and S. aureus, but also for MIC-relevant bacteria such as Fe(III)-reducing Shewanella spec. Another aspect of the biofilm matrix is the establishment of microscale environments with conditions, such as anaerobic or acidic microenvironments, which promotes a diverse multispecies community. However, the detection and visualization of such small-scale microenvironments is rather challenging. Further, it could directly indicate the activity of microorganism influencing or inducing corrosion processes. Therefore, dye-stained nanoscale particles, bearing pH-responsive fluorophores at the surface, were developed to measure the pH at the biofilm’s surface and within the matrix using confocal laser scanning microcopy. The particles will be further advanced to measure other environmentally relevant parameters, including oxygen concentration, and concentrations of selected metal ions indicative of corrosion of e.g., materials used for water pipelines. In the future, our platform and its analytical tools will be employed to study the formation of biofilms in dependency of the respective support material, its surface properties like roughness, and the microbial community. T2 - VAAM Jahrestagung CY - Würzburg, Germany DA - 05.03.2017 KW - MIC KW - Biophotonik KW - LIPSS KW - Nanoparticel based pH-probes PY - 2017 AN - OPUS4-39417 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Spaltmann, Dirk A1 - Ayerdi Gomez, A. A1 - Slachciak, Nadine A1 - Zubia Aranburu, J. A1 - Zabala, A. A1 - Aginagalde, A. A1 - Bonse, Jörn T1 - Improvement of the tribological performance of titanium alloy using FS-laser-induced periodic surface structures in combination with ZDDP and ionic liquid lubricant additives N2 - The performance of titanium alloy (Ti6Al4V) surfaces was investigated in lubricated reciprocating sliding tribological tests (RSTT). Special emphasis was laid on the effect of surface nanostructures in area of contact on the respective friction and wear behaviour. These so-called laser-induced periodic surface structures (LIPSS, ripples) were produced on the titanium alloy surface upon scan processing in air by an ultrashort pulsed femtosecond (fs) laser. As lubricant served two types of base oils, a pure polyalcylene-glycol, and an SAE 0W30 oil containing only antioxidants and temperature stabilizers. Tribological tests were carried out on polished as well as LIPSS covered areas using both types of base oil. A test metrics was established, combining the additive 2-ethylhexyl-zincdithiophosphate (ZDDP) or the ionic liquid [P6,6,6,14] [DEHP] (98% purity) with the respective base oils. The test metrics also considered the orientation of motion with respect to the orientation of the structures formed on the surface. Results are presented which show that the interplay between LIPSS and the local chemistry formed by the respective additives is beneficial for the tribological behaviour of the titanium alloy. Certain combinations of base oil, additive and LIPSS reduced friction and wear significantly in the tribological contact. T2 - 64. Tribologie-Fachtagung CY - Göttingen, Germany DA - 25.09.2023 KW - TiAl64V KW - 100Cr6 KW - Friction KW - Wear KW - LIPSS KW - Lubrication KW - PAG KW - Ionic liquid PY - 2023 AN - OPUS4-58641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -