TY - JOUR A1 - Yu, Z. A1 - Musnier, B. A1 - Wegner, Karl David A1 - Henry, M. A1 - Chovelon, B. A1 - Desroches-Castan, A. A1 - Fertin, A. A1 - Resch-Genger, Ute A1 - Bailly, S. A1 - Coll, J.-L. A1 - Usson, Y, A1 - Josserand, V. A1 - Le Gúevel, X. T1 - High-Resolution Shortwave Infrared Imaging of Vascular Disorders Using Gold Nanoclusters N2 - We synthesized a generation of water-soluble, atomically precise gold nanoclusters (Au NCs) with anisotropic Surface containing a short dithiol pegylated chain (AuMHA/TDT). The AuMHA/TDT exhibit a high brightness (QY ∼ 6%) in the shortwave infrared (SWIR) spectrum with a detection above 1250 nm. Furthermore, they show an extended half-life in blood (t1/2ß = 19.54 ± 0.05 h) and a very weak accumulation in organs. We also developed a non-invasive, whole-body vascular imaging system in the SWIR window with high-resolution, benefiting from a series of Monte Carlo image processing. The imaging process enabled to improve contrast by 1 order of magnitude and enhance the spatial Resolution by 59%. After systemic administration of these nanoprobes in mice, we can quantify vessel complexity in depth (>4 mm), allowing to detect very subtle vascular disorders non-invasively in bone morphogenetic protein 9 (Bmp9)-deficient mice. The combination of these anisotropic surface charged Au NCs plus an improved SWIR imaging device allows a precise mapping at high-resolution and an in depth understanding of the organization of the vascular network in live animals. KW - Nanoparticle KW - Nanosensor KW - Fluorescence KW - Metal cluster KW - NIR KW - SWIR KW - Photophysics KW - Ligand KW - Size KW - Surface chemistry KW - Quantum yield KW - Mechanism KW - Lifetime KW - Decay kinetics PY - 2020 DO - https://doi.org/10.1021/acsnano.0c01174 VL - 14 IS - 4 SP - 4973 EP - 4981 PB - ACS Publication AN - OPUS4-50671 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zou, Q. A1 - Marcelot, C. A1 - Ratel-Ramond, N. A1 - Yi, X. A1 - Roblin, P. A1 - Frenzel, Florian A1 - Resch-Genger, Ute A1 - Eftekhari, A. A1 - Bouchet, A. A1 - Coudret, C. A1 - Verelst, M. A1 - Chen, X. A1 - Mauricot, R. A1 - Roux, C. T1 - Heterogeneous Oxysulfide@Fluoride Core/ Shell Nanocrystals for Upconversion-Based Nanothermometry N2 - Lanthanide (Ln3+)-doped upconversion nanoparticles (UCNPs) often suffer from weak luminescence, especially when their sizes are ultrasmall (less than 10 nm). Enhancing the upconversion luminescence (UCL) efficiency of ultrasmall UCNPs has remained a challenge that must be undertaken if any practical applications are to be envisaged. Herein, we present a Ln3+-doped oxysulfide@fluoride core/shell heterostructure which shows efficient UCL properties under 980nm excitation and good stability in solution. Through epitaxial heterogeneous growth, a ∼4 nm optically inert β-NaYF4 shell was coated onto ∼5 nm ultrasmall Gd2O2S:20%Yb,1%Tm. These Gd2O2S:20%Yb,1%Tm@NaYF4 core/shell UCNPs exhibit a more than 800-fold increase in UCL intensity compared to the unprotected core, a 180-fold increase in luminescence decay time of the 3H4 → 3H6 Tm3+ transition from 5 to 900 μs, and an upconversion quantum yield (UCQY) of 0.76% at an excitation power density of 155 W/cm2. Likewise, Gd2O2S:20%Yb,2%Er@NaYF4 core/shell UCNPs show a nearly 5000-fold increase of their UCL intensity compared to the Gd2O2S:20%Yb,2%Er core and a maximum UCQY of 0.61%. In the Yb/Er core−shell UCNP system, the observed variation of luminescence intensity ratio seems to originate from a change in lattice strain as the temperature is elevated. For nanothermometry applications, the thermal sensitivities based on thermally coupled levels are estimated for both Yb/Tm and Yb/Er doped Gd2O2S@NaYF4 core/shell UCNPs. KW - Upconversion nanoparticle KW - Nanosensor KW - Lanthanide KW - Surface coating KW - Quantum yield KW - Photophysic PY - 2022 DO - https://doi.org/10.1021/acsnano.2c02423 SN - 1936-0851 SP - 1 EP - 11 PB - ACS Publications AN - OPUS4-55440 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Harald Rune T1 - Imaging of local pH in biofilm using polymeric sensors: towards the elucidation of microbial induced corrosion N2 - Microbial induced corrosion (MIC) is a crucial problem in many technical plants as well as fuel tanks, leading to considerable damage and huge financial losses. Successful prevention of MIC requires the localization of first signs of corrosion as well as the identification of factors influencing the corrosion process. In this respect, also the determination of corrosion rates can be of interest for the possible prevention of MIC. Hence, there is a growing need for sensitive and preferably inexpensive tools that enable the early detection of MIC. Of special interest are methods, which provide spatially and time-resolved information and allow the study of changes on metal surfaces as prerequisites for a more detailed analysis of ongoing corrosion processes at a MIC-affected site. Biofilm formation can lead to changes in pH, oxygen and chloride concentration as well as to the release of certain metal ions like Fe(II) and Mn(II) depending on the type of metal surface involved. Hence, optical methods enabling the detection of these analytes at very low concentration and monitoring of their changes can be used for MIC detection. Here, we propose to utilize polymeric nanosensors for MIC detection via the determination of the local pH value changes in different biofilms. Such nanosensors are known to have several advantages in imaging applications such as intracellular pH measurements including the ease of doping or labeling with a multitude of analyte-responsive and inert dye molecules for the realization of a high analyte sensitivity and ratiometric sensing. Moreover, they can be surface functionalized with target-specific ligands e.g., lectins, for the specific binding to the outer surface of certain types of bacteria. In this respect, different polymer architectures will be studied to identify an optimal candidate in terms of imaging performance in conjunction with several classes of pH-responsive fluorescent dyes like cyanines, aza-BODIPYs, and xanthenes, utilizing different mechanism of signal generation such as photo-induced electron transfer or protonation-induced changes in the spectral position of absorption and emission spectra. T2 - Europtrode CY - Graz, Austria DA - 20.03.2016 KW - Nanosensor KW - Microbial induced corrosion KW - Imaging KW - Nanosensor KW - Mikrobiell induzierte Korrosion KW - Bildgebung PY - 2016 AN - OPUS4-35628 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Harald T1 - Polymeric sensors as imaging tools for local pH in biofilm for early detection of microbial induced corrosion T1 - Polymersensoren als Werkzeug für die Bildgebung von lokalen pH in Biofilmen für die frühzeitige Erkennung von mikrobiell induzierter Korrosion N2 - Microbial induced corrosion (MIC) is a crucial problem in many technical plants as well as fuel tanks, leading to considerable damage and huge financial losses. Successful prevention of MIC requires the localization of first signs of corrosion as well as the identification of factors influencing the corrosion process.1 Hence, there is a growing need for sensitive and preferably inexpensive tools that enable the early detection of MIC. Of high importance are methods, which provide spatially and time-resolved information and allow the study of changes on metal surfaces as prerequisites for a more detailed analysis of ongoing corrosion processes at a MIC-affected site.2 In this respect, also the determination of corrosion rates can be of interest for the possible prevention of MIC. T2 - 11th International Symposium on Polymer Therapeutics CY - Valencia, Spain DA - 23.05.2016 KW - Bildgebung KW - Mikrobiell induzierte Korrosion KW - Nanosensor KW - Imaging KW - Microbial induced corrosion KW - Nanosensor PY - 2016 AN - OPUS4-37138 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Harald T1 - Polymeric sensors as imaging tools for local pH in biofilm for early detection of microbial induced corrosion N2 - Microbial induced corrosion (MIC) is a crucial problem in many technical plants as well as fuel tanks, leading to considerable damage and huge financial losses. Successful prevention of MIC requires the localization of first signs of corrosion as well as the identification of factors influencing the corrosion process.1 Hence, there is a growing need for sensitive and preferably inexpensive tools that enable the early detection of MIC. Of high importance are methods, which provide spatially and time-resolved information and allow the study of changes on metal surfaces as prerequisites for a more detailed analysis of ongoing corrosion processes at a MIC-affected site.2 In this respect, also the determination of corrosion rates can be of interest for the possible prevention of MIC. T2 - 11th International Symposium on Polymer Therapeutics CY - Valencia, Spain DA - 23.05.2016 KW - Bildgebung KW - Mikrobiell induzierte Korrosion KW - Nanosensor KW - Imaging KW - Microbial induced corrosion PY - 2016 AN - OPUS4-37139 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kromer, Charlotte A1 - Katz, Aaron A1 - Feldmann, Ines A1 - Laux, Peter A1 - Luch, Andreas A1 - Tschiche, Harald R. T1 - A targeted fluorescent nanosensor for ratiometric pH sensing at the cell surface N2 - AbstractThe correlation between altered extracellular pH and various pathological conditions, including cancer, inflammation and metabolic disorders, is well known. Bulk pH measurements cannot report the extracellular pH value at the cell surface. However, there is a limited number of suitable tools for measuring the extracellular pH of cells with high spatial resolution, and none of them are commonly used in laboratories around the world. In this study, a versatile ratiometric nanosensor for the measurement of extracellular pH was developed. The nanosensor consists of biocompatible polystyrene nanoparticles loaded with the pH-inert reference dye Nile red and is surface functionalized with a pH-responsive fluorescein dye. Equipped with a targeting moiety, the nanosensor can adhere to cell membranes, allowing direct measurement of extracellular pH at the cell surface. The nanosensor exhibits a sensitive ratiometric pH response within the range of 5.5–9.0, with a calculated pKa of 7.47. This range optimally covers the extracellular pH (pHe) of most healthy cells and cells in which the pHe is abnormal, such as cancer cells. In combination with the nanosensors ability to target cell membranes, its high robustness, reversibility and its biocompatibility, the pHe nanosensor proves to be well suited for in-situ measurement of extracellular pH, even over extended time periods. This pH nanosensor has the potential to advance biomedical research by improving our understanding of cellular microenvironments, where extracellular pH plays an important role. KW - pH sensor KW - pH KW - Targeting, Nanoparticles KW - pHe KW - Nanosensor KW - Extracellular pH PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-604339 DO - https://doi.org/10.1038/s41598-024-62976-2 VL - 14 IS - 1 SP - 1 EP - 12 PB - Springer Science and Business Media LLC AN - OPUS4-60433 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -