TY - JOUR A1 - Rodriguez, Santiago A1 - Kumanski, Sylvain A1 - Ayed, Zeineb A1 - Fournet, Aurélie A1 - Bouanchaud, Charlène A1 - Sagar, Amin A1 - Allemand, Frédéric A1 - Baulin, Vladimir A. A1 - Resch‐Genger, Ute A1 - Cortés, Juan A1 - Sibille, Nathalie A1 - Chirot, Fabien A1 - Wegner, Karl David A1 - Antoine, Rodolphe A1 - Le Guével, Xavier A1 - Bernadó, Pau T1 - Programming the Optoelectronic Properties of Atomically Precise Gold Nanoclusters Using the Conformational Landscape of Intrinsically Disordered Proteins N2 - The rational design of hybrid nanomaterials with precisely controlled properties remains a central challenge in materials science. While atomically precise gold nanoclusters (Au‐NCs) offer molecule‐like control over a metallic core, tuning their optoelectronic behavior via surface engineering is often empirically driven. Here, we establish a design principle by demonstrating that the conformational landscape of intrinsically disordered proteins (IDP) can be used as a programmable scaffold to rationally modulate the photophysical properties of a covalently bound Au‐NC. We synthesized a series of bioconjugates between Au 25 nanoclusters and bioengineered IDPs containing a variable number of cysteine anchoring points. A combination of mass spectrometry, small‐angle X‐ray scattering, and modeling on the conjugates indicates that increasing the number of covalent anchors systematically restricts the conformational ensemble, inducing a progressively more compact protein shell around nanoclusters. This structural rigidification at the interface directly translates into a 15‐fold enhancement of the Au‐NC near‐infrared photoluminescence and a six‐fold increase in its average lifetime. Our findings demonstrate that the conformational plasticity of IDPs and the capacity to engineer them can be harnessed as a molecular tuning knob, moving to a new regime of programmable soft‐matter control over the properties of quantum‐confined nanomaterials for tailored biotechnological applications. KW - Fluorescence KW - Custer KW - Nano KW - Advanced material KW - Characterization KW - Fluorescence quantum yield KW - Integrating sphere spectroscopy KW - Thiol ligands KW - Gold KW - Surface chemistry KW - SWIR KW - Mass spectrometry KW - Protein PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-655086 DO - https://doi.org/10.1002/chem.202502991 SN - 0947-6539 SP - 1 EP - 9 PB - Wiley VHC-Verlag AN - OPUS4-65508 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gugin, Nikita A1 - Schwab, Alexander A1 - Carraro, Francesco A1 - Tavernaro, Isabella A1 - Falkenhagen, Jana A1 - Villajos, Jose A1 - Falcaro, Paolo A1 - Emmerling, Franziska T1 - ZIF-8-based biocomposites via reactive extrusion: towards industrial-scale manufacturing N2 - Mechanochemistry, a sustainable synthetic method that minimizes solvent use, has shown great promise in producing metal–organic framework (MOF)-based biocomposites through ball milling. While ball milling offers fast reaction times, biocompatible conditions, and access to previously unattainable biocomposites, it is a batch-type process typically limited to gram-scale production, which is insufficient to meet commercial capacity. We introduce a scalable approach for the continuous solid-state production of MOF-based biocomposites. Our study commences with model batch reactions to examine the encapsulation of various biomolecules into Zeolitic Imidazolate Framework-8 (ZIF-8) via hand mixing, establishing a foundation for upscaling. Subsequently, the process is scaled up using reactive extrusion, enabling continuous and reproducible kilogram-scale production of bovine serum albumin (BSA)@ZIF-8 with tunable protein loading. Furthermore, we achieve the one-step formation of shaped ZIF-8 extrudates encapsulating clinical therapeutic hyaluronic acid (HA). Upon release of HA from the composite, the molecular weight of HA is preserved, highlighting the industrial potential of reactive extrusion for the cost-effective and reliable manufacturing of biocomposites for drug-delivery applications. KW - Mechanochemistry KW - Extrusion KW - Biocompoites KW - MOFs PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654777 DO - https://doi.org/10.1039/D5TA08276E SN - 2050-7496 SP - 1 EP - 14 PB - Royal Society of Chemistry AN - OPUS4-65477 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - How to get it right with photoluminescence measurements in the UV/VIS/NIR N2 - Optical measurements of transparent solutions of organic dyes and semiconductor quantum dots and scattering materials such as luminescent nanocomposites and microparticles and phosphors dispersed in liquid and solid matrices play an important role in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. A key performance parameter is the photoluminescence quantum yield QY, i.e., the number of emitted per number of absorbed photons. QY of transparent luminophore solutions can be obtained relative to a fluorescence QY standard of known QY. Such relative QY measurements require a calibrated spectrofluorometer. Here, we address typical sources of uncertainty for luminescence measurements and relative and absolute QY measurements from the instrument and material side and provide recommendations to circumvent or at least minimize them for transparent and scattering samples in the UV/vis/NIR/SWIR. T2 - Workshop "Photoluminescence Spectroscopy and its application in Materials Research" CY - Vienna, Austria DA - 19.02.2026 KW - Quality assurance KW - Reference material KW - Fluorescence KW - Dye KW - Traceability KW - Metrology KW - Calibration KW - Reference data KW - Reference product KW - Digital certificate KW - NIR KW - Instrument performance validation PY - 2026 AN - OPUS4-65575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - McGonigle, Rebecca A1 - Glasgow, Jodie A1 - Houston, Catriona A1 - Cameron, Iain A1 - Homann, Christian A1 - Black, Dominic J. A1 - Pal, Robert A1 - MacKenzie, Lewis E. ED - MacKenzie, Lewis E. T1 - Autoclave reactor synthesis of upconversion nanoparticles, unreported variables, and safety considerations N2 - Autoclave reactors are widely used across chemical and biological sciences, including for the synthesis of upconversion nanoparticles (UCNPs) and other nanomaterials. Yet, the details of how autoclave reactors are used in such synthesis are rarely reported in the literature, leaving several key synthesis variables widely unreported and thereby hampering experimental reproducibility. In this perspective, we discuss the safety considerations of autoclave reactors and note that autoclaves should only be used if they are (a) purchased from reputable suppliers/manufacturers and (b) have been certified compliant with relevant safety standards. Ultimately, using unsuitable autoclave equipment can pose a severe physical hazard and may breach legal safety requirements. In addition, we highlight several parameters in autoclave synthesis that should be reported as standard to maximise the reproducibility of autoclave synthesis experiments across materials and chemistry research. We encourage users of autoclave synthesis vessels to: (1) adopt high-safety autoclaves and (2) report the many experimental variables involved to enhance experimental reproducibility. KW - Reference material KW - Nano KW - Particle KW - Shell KW - Fluorescence KW - Lifetime KW - Decay kinetics KW - Synthesis KW - Quality assurance KW - Method KW - Energy transfer KW - Upconversion KW - Autoclave synthesis KW - Data comparability PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625672 DO - https://doi.org/10.1038/s42004-025-01415-3 VL - 8 IS - 1 SP - 1 EP - 7 PB - Springer Science and Business Media LLC AN - OPUS4-62567 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlögl, Johanna A1 - Krappe, Alexander R. A1 - Fürstenwerth, Paul C. A1 - Brosius, Amelie L. A1 - Fasting, Carlo A1 - Hoffmann, Kurt F. A1 - Resch-Genger, Ute A1 - Eigler, Siegfried A1 - Steinhauer, Simon A1 - Riedel, Sebastian T1 - Luminescent Perhalofluoro Trityl Radicals N2 - In this proof-of-concept study, we show that polyfluorinated trityl radicals with the, to this date, highest fluorination grade can be accessed in quantitative yields in a straightforward manner starting from the perfluorinated trityl cation. The trityl skeleton is functionalized with trimethylsilyl halides to yield perhalofluoro trityl cations, which are subsequently reduced using commercial zinc powder. In this way, we prepare three perhalofluoro trityl radicals and analyze the impact of the fluorine ligands on their electro-optical properties, revealing some interesting trends. In comparison to literature-known polychlorinated trityl radicals, the new polyfluorinated derivatives exhibit substantially higher fluorescence quantum yields, longer luminescence lifetimes, and an expanded emission range that extends into the yellow spectral region. They further display enhanced photostability under light irradiation. In radical-stained polystyrene nanoparticles, an additional broad emission band in the red−NIR wavelength region is observed, which is attributed to excimer formation. Finally, the stability of the new radicals is investigated under ambient conditions, showing the slow conversion with atmospheric oxygen yielding the respective peroxides, which are characterized by single-crystal X-ray diffraction. All in all, our study extends the present scope of luminescent trityl radicals, as the functionalization of the perfluorinated cationic precursor unlocks the path toward a vast variety of polyfluorinated trityl radicals. KW - Dye KW - Fluorescence KW - Radical KW - Synthesis KW - Mechanism KW - Signal enhancement KW - Nano KW - Particle KW - Characterization KW - Quantum yield KW - Photophysics KW - Lifetime KW - Polarity KW - Polymer KW - Solvatchromism KW - Excimer PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-647973 DO - https://doi.org/10.1021/jacs.5c16418 SN - 0002-7863 VL - 147 IS - 46 SP - 1 EP - 8 PB - American Chemical Society (ACS) AN - OPUS4-64797 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Resch-Genger, Ute A1 - Abram, Sarah-Luise A1 - Tavernaro, Isabella A1 - Zou, Shan A1 - Johnston, Linda T1 - Behind the Paper: Nanoscale Reference and Test Materials for the Validation of Characterization Methods for Engineered Nanomaterials – Current State, Limitations and Needs N2 - Engineered nanomaterials (NMs) of different material composition, morphology, and surface chemistry are widely used in material and life sciences. For NM quality control and risk assessment, NM key properties must be characterized with validated methods, requiring reference materials (RMs). KW - Engineered Nanomaterials KW - Nanoscale reference materials KW - Interlaboratory comparisons KW - Traceability KW - Standardization and Regulation KW - Nano KW - Particle KW - Quality assurance KW - Surface chemistry PY - 2025 UR - https://communities.springernature.com/posts/nanoscale-reference-and-test-materials-for-the-validation-of-characterization-methods-for-engineered-nanomaterials-current-state-limitations-and-needs SP - 1 EP - 3 PB - Springer Nature CY - Online AN - OPUS4-62572 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Haroun, A. A. A. A1 - Derbala, H. A. A1 - Bassioni, G. A1 - Resch-Genger, Ute A1 - Shafik, E. S. A1 - Hassan, A. M. A. T1 - N-aminophthalimide as a novel UV-stabilizer to promote physico-mechanical properties of highdensity polyethylene (HDPE) N2 - This study aimed to evaluate the efficacy of Naminophthalimide (NAP) as a novel UV-stabilizer for highdensity polyethylene (HDPE) in improving its physicomechanical properties under UV exposure. NAP was synthesized by interaction between phthalimide and hydrazine hydrate. It was incorporated into HDPE with different weight ratios (1, 1.5, 2, and 3%), and its performancewas compared with Hostavin as a traditional UV stabilizer. The HDPE composites were exposed to UV irradiation for different periods (7 and 14 days) to evaluate their photodegradation behavior. Tensile strength, elongation at break were assessed before and after UV exposure. Also, oxidation induction time (OIT), melt flow rate (MFR), Vicat softening temperature were evaluated. Hostavin incorporation reduced tensile strength from 22.36 to 20.62MPa at higher concentrations. It has been found that 3% Hostavin, significantly improved elongation at break, increasing from 423% to 1,170%, suggesting enhanced flexibility. In contrast, NAP increased tensile strength to 22.9MPa and moderately enhanced elongation but slightly declined at 3%due to potential over-stabilization. Under UV exposure, retained tensile strength and elongation was improved with stabilizer content, which increasing tensile strength retention. The HDPE that containing NAP showed enhanced UV resistance and superior retention of mechanical properties compared to Hostavin. KW - Polymer KW - Advanced materials KW - Quality assurance KW - Stabilizer KW - Synthesis KW - Physico-mechanical properties PY - 2025 DO - https://doi.org/10.1515/polyeng-2024-0262 SN - 2191-0340 SP - 1 EP - 8 PB - De Gruyter CY - Berlin AN - OPUS4-63534 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Reliable Photoluminescence Quantum Yields – New Reference Materials and Interlaboratory Comparisons N2 - The rational design and choice of molecular and nanoscale reporters, the comparison of different emitter classes, and photophysical and mechanistic studies require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR. To improve the reliability and comparability of photoluminescence and QY measurements across laboratories, pitfalls, achievable uncertainties, and material-specific effects related to certain emitter classes must be explored. Also, suitable protocols and reference materials are needed which have been validated in interlaboratory comparisons for different wavelength regions and transparent and scattering luminophores.[1] Based on absolute and relative photoluminescence measurements of functional dyes and luminescent nanomaterials, reliable methods for determining QY of transparent and scattering luminophores, nonlinear emitters, and solid luminescent nanomaterials have been developed.[1-4] Thereby, material- and method-related uncertainties of relative and absolute QY measurements and achievable uncertainties could be quantified for linear and nonlinear UV/vis/NIR/SWIR emitters and lately for also luminescent and scattering materials and solid phoshors. In this context, we present the development and certification of a first set of UV/vis/NIR quantum yield standards with a complete uncertainty budget,[5] which present simple tools for a better comparability of QY measurements. In addition, a first interlaboratory comparison of absolute QY measurements of solid and scattering LED converter materials with integrating sphere spectroscopy has been performed.[5] The outcome of this study is presented, thereby addressing common pitfalls and measurement uncertainties and providing recommendations for the performance of reliable QY measurements of linear and non-linear emitters in transparent, scattering, and solid samples. T2 - Anakon 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Quality assurance KW - Reference material KW - Method KW - Fluorescence KW - Quantum yield KW - Absolute KW - Integrating sphere spectroscopy KW - Interlaboratory comparison KW - Dye KW - Film KW - Nano KW - Particle KW - Scattering KW - Uncertainty KW - LED converter PY - 2025 AN - OPUS4-62792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osiopova, Viktoriia A1 - Tavernaro, Isabella A1 - Ge, L. A1 - Kitzmann, W. R. A1 - Heinze, K. A1 - Reithofer, M. R. A1 - Resch-Genger, Ute T1 - Complete protection of NIR-luminescent molecular rubies from oxygen quenching in air by L-arginine-mediated silica nanoparticles N2 - The application of emerging luminophores such as near-infrared (NIR) emissive complexes based on earth-abundant chromium as central ion and triplet-triplet annihilation upconversion (TTA-UC) systems in air as optical reporters for bioimaging or photonic materials for energy conversion requires simple and efficient strategies for their complete protection from uminescence quenching by oxygen. Therefore, we explored the influence of sol–gel synthesis routes on the oxygen protection efficiency of the resulting core and core/shell silica nanoparticles (SiO2 NPs), utilizing the molecular ruby-type luminophores CrPF6 ([Cr(ddpd)2](PF6)3; ddpd = N,N'-dimethyl-N,N'-dipyridin-2-ylpyridin-2,6-diamine) and CrBF4 ([Cr(ddpd)2](BF4)3) with their oxygendependent, but polarity-, proticity-, viscosity-, and concentration-independent luminescence as optical probes for oxygen permeability. The sol–gel chemistry routes we assessed include the classical Stöber method and the underexplored Larginine approach, which relies on the controlled hydrolysis of tetraethoxysilane (TEOS) in a biphasic cyclohexane/water system with the catalyst L-arginine. As demonstrated by luminescence measurements of air- and argon-saturated dispersions of CrPF6- and CrBF4-stained SiO2 NPs of different size and particle architecture, utilizing the luminescence decay kinetics of argon-saturated solutions of CrPF6 and CrBF4 in acetonitrile (ACN) as benchmarks, only SiO2 NPs or shells synthesized by the L-arginine approach provided complete oxygen protection of the CrIII complexes under ambient conditions. We ascribe the different oxygen shielding efficiencies of the silica networks explored to differences in density and surface chemistry of the resulting nanomaterials and coatings, leading to different oxygen permeabilities. Our Larginine based silica encapsulation strategy can open the door for the efficient usage of oxygen-sensitive luminophores and TTA-UC systems as optical reporters and spectral shifters in air in the future. KW - Quality assurance KW - Fluorescence KW - Quantification KW - Advanced materials KW - Nano KW - Quantum yield KW - NIR KW - Characterization KW - Electron microscopy KW - Silica KW - Synthesis KW - Oxygen sensing KW - Surface KW - Doping KW - Lifetime KW - Cr(III) complex KW - Shielding KW - Sensing PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-638271 DO - https://doi.org/10.26599/NR.2025.94907241 SN - 1998-0000 VL - 18 IS - 3 SP - 1 EP - 13 PB - SciOpen AN - OPUS4-63827 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Fallisch, A. A1 - Petrov, E. P. A1 - Salhany, R. A1 - Forthman, C. A1 - Guttenberg, Z. A1 - Nitschke, R. T1 - Spectral fluorescence standards for the calibration and performance validation of fluorescence microscopes N2 - The standardization and calibration of fluorescence microscopy have become increasingly vital due to the wide-spread use of in life and materials sciences. As the demand for reliable and user-friendly methods to assess micro-scope performance grows, universal calibration tools accessible to both researchers and vendors are needed. To support the standardization of characterization methods in microscopy, it is crucial to provide calibration tools together with standardized operating procedures for their effective implementation. The public-funded project "FluMiKal"* develops calibration tools in the shape of typical microscopic slides to assess key parameters such as spatial resolution, point spread function, spectral sensitivity, linearity and sensitivity of the detection system. The focus is on creating calibration tools that are user-friendly, robust, and versatile in their application. This work addresses the critical parameter of wavelength-dependent spectral sensitivity, which affects the meas-ured signals from the instrument side, yielding instrument-specific data and instrument aging-induced changes over time. For this purpose, μ-slides from ibidi with six channels are used, allowing them to be filled with different solutions containing molecular or nanoscale fluorophores with well-characterized absorption and fluorescence properties. The certified spectral fluorescence standards BAM-F003, F004, F005, and F007 assessed provided as ethanolic solutions by the Federal Institute for Materials Research and Testing (BAM), cover a broad spectral range from the blue to the near-infrared [1], [2]. Dye-based slide prototypes have been used to determine the spectral sensitivity of confocal microscopes from different vendors with various detector types by acquiring the spectral data of the BAM dyes under standardized measurement conditions, demonstrating the applicability of this concept. Proof-of-concept experiments could demonstrate the proper sealing of the slides. Further experiments will explore long-term stability and their potential as standards for relative intensity calibrations. * FluMiKal is funded by the Federal Ministry for Economic Affairs and Climate Action, Germany (WIPANO FKZ 03TN0047B) [1] doi: 10.1007/4243_2008_028. [2] doi: 10.1007/s00216-024-05723-w. T2 - European Light Microscopy Initiative - ELMI 2025 CY - Heidelberg, Germany DA - 03.06.2025 KW - Fluorescence KW - Advanced material KW - Validation KW - Calibration KW - Method comparison KW - Reference material KW - Dye KW - Fluorescence standard KW - Microscopy KW - CLSM KW - Imaging PY - 2025 AN - OPUS4-64206 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -