TY - JOUR A1 - Döring, Sarah A1 - Wulfes, Birte S. A1 - Atanasova, Aleksandra A1 - Jaeger, Carsten A1 - Walzel, Leopold A1 - Tscheuschner, Georg A1 - Flemig, Sabine A1 - Gawlitza, Kornelia A1 - Feldmann, Ines A1 - Konthur, Zoltán A1 - Weller, Michael G. T1 - Corundum Particles as Trypsin Carrier for Efficient Protein Digestion N2 - Reusable enzyme carriers are valuable for proteomic workflows, yet many supports are expensive or lack robustness. This study describes the covalent immobilization of recombinant trypsin on micrometer-sized corundum particles and assesses their performance in protein digestion and antibody analysis. The corundum surface was cleaned with potassium hydroxide, silanized with 3-aminopropyltriethoxysilane and activated with glutaraldehyde. Recombinant trypsin was then attached, and the resulting imines were reduced with sodium cyanoborohydride. Aromatic amino acid analysis (AAAA) estimated an enzyme loading of approximately 1 µg/mg. Non-specific adsorption of human plasma proteins was suppressed by blocking residual aldehydes with a Tris-glycine-lysine buffer. Compared with free trypsin, immobilization shifted the temperature optimum from 50 to 60 °C and greatly improved stability in 1 M guanidinium hydrochloride. Activity remained above 80% across several reuse cycles, and storage at 4 °C preserved functionality for weeks. When applied to digesting the NISTmAb, immobilized trypsin provided peptide yields and sequence coverage comparable to soluble enzyme and outperformed it at elevated temperatures. MALDI-TOF MS analysis of Herceptin digests yielded fingerprint spectra that correctly identified the antibody and achieved 60% sequence coverage. The combination of low cost, robustness and analytical performance makes corundum-immobilized trypsin an attractive option for research and routine proteomic workflows. N2 - Wiederverwendbare Enzymcarrier sind für proteomische Arbeitsabläufe von großem Wert, doch viele Trägermaterialien sind teuer oder nicht robust genug. Diese Studie beschreibt die kovalente Immobilisierung von rekombinantem Trypsin auf mikrometergroßen Korundpartikeln und bewertet deren Leistungsfähigkeit beim Proteinverdau und der Antikörperanalyse. Die Korundoberfläche wurde mit Kaliumhydroxid gereinigt, mit 3-Aminopropyltriethoxysilan silanisiert und mit Glutaraldehyd aktiviert. Anschließend wurde rekombinantes Trypsin gebunden, und die entstandenen Imine wurden mit Natriumcyanoborhydrid reduziert. Die aromatische Aminosäureanalyse (AAAA) ergab eine geschätzte Enzymbeladung von etwa 1 µg/mg. Die unspezifische Adsorption von menschlichen Plasmaproteinen wurde durch Blockierung der restlichen Aldehyde mit einem Tris-Glycin-Lysin-Puffer unterdrückt. Im Vergleich zu freiem Trypsin verschob die Immobilisierung das Temperaturoptimum von 50 auf 60 °C und verbesserte die Stabilität in 1 M Guanidiniumhydrochlorid erheblich. Die Aktivität blieb über mehrere Wiederverwendungszyklen hinweg bei über 80 %, und die Lagerung bei 4 °C bewahrte die Funktionalität über Wochen hinweg. Beim Verdau des NISTmAb lieferte das immobilisierte Trypsin Peptidausbeuten und Sequenzabdeckungen, die mit denen des löslichen Enzyms vergleichbar waren, und übertraf dieses bei erhöhten Temperaturen. Die MALDI-TOF-MS-Analyse von Herceptin-Verdauen ergab Fingerabdruck-Spektren, die den Antikörper korrekt identifizierten und eine Sequenzabdeckung von 60 % erreichten. Die Kombination aus niedrigen Kosten, Robustheit und analytischer Leistungsfähigkeit macht auf Korund immobilisiertes Trypsin zu einer attraktiven Option für die Forschung und routinemäßige proteomische Arbeitsabläufe. KW - Bottom-up proteomics KW - Solid-phase digestion KW - Biopharmaceutical analysis KW - Peptide mapping KW - Non-specific binding KW - amino acid analysis PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657021 DO - https://doi.org/10.3390/biotech15010002 SN - 2673-6284 VL - 15 IS - 1 SP - 1 EP - 23 PB - MDPI CY - Basel AN - OPUS4-65702 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Singh, Chandan T1 - Oxidation resistant, interlaced 3D MXene composite for electrochemical biosensing N2 - BSA (Bovine Serum Albumin) as an oxidation resistant for Ti₃C₂Tx-MXene : BSA derived method protects 3D interlaced Ti₃C₂Tx–CNT nanocomposite from oxidative degradation, preserving their structural integrity . Application in biosensing: After the removal of excess BSA, the nanocomposite were amino-silane functionalized and decorated with anti-SARS-CoV-2 antibodies, enabling selective detection of SARS-CoV-2 nucleocapsid protein (SNP) in saliva. Performance of the biosensor: The designed biosensor showed high sensitivity (LoD 23.6 pM), wide detection range (0.1–500 ng/mL), no cross-reactivity, and improved response due to the preserved 3D interwoven nanostructure. T2 - Graphene Week 2025 CY - Vicenza, Italy DA - 22.09.2025 KW - Nanocomposite KW - Biosensor KW - SARS-CoV-2 PY - 2025 AN - OPUS4-65728 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kumari, Surbhi T1 - Tagetes erecta synthesized bimetallic Ag–Au nanoparticles and their potential application in electrochemical detection and estimation of ampicillin in raw milk N2 - This study focuses on the green synthesis of Ag–Au nanoparticles using Tagetes erecta extract and their potential application in electrochemical detection and estimation of ampicillin in raw milk. The Ag–Au nanoparticles were covalently bonded to the hydroxylated fluorine-doped tin oxide electrode surface through silane chemistry enabling the effective interaction of the 5' thiolated-aptamer with the nanoparticle-modified surface for aptasensor development. The aptasensor displayed a limit of detection of 0.40 ng mL−1 and a stability of 30 days. Moreover, the aptasensor demonstrated reliable performance with both spiked milk samples and real milk samples, detecting a concentration of 194 ng mL−1 in raw milk with results closely matching with those obtained by the LC-MS technique. T2 - SALSA Make & Measure 2025: Interfaces CY - Berlin, Germany DA - 10.09.2025 KW - Aptamer KW - Antibiotic KW - Biosensing PY - 2025 AN - OPUS4-65727 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Meyer, Klas T1 - Benchtop NMR-Spektroskopie im industriellen Produktionsumfeld: Herausforderungen auf dem Weg zur Online-Prozessintegration N2 - Benchtop-NMR Spektrometer erobern erfolgreich seit Jahren die Labore und haben sich als ein vielseitiges analytisches Werkzeug etabliert. Zunächst stark fokussiert auf den Forschungs-bereich, sind sie heute zunehmend auch nahe der Produktion auf dem Vormarsch. Die Zielstellung ist nur selten der Ersatz von klassischer „Hochfeld“-NMR-Spektroskopie. Vielmehr erschließen die kompakten Geräte oftmals neue Anwendungsfelder, beispielsweise in der Online-Reaktionsverfolgung im Labor oder der schnellen at-line Qualitätskontrolle in der chemischen Produktion. Hier kommen die Vorteile der geringeren Anschaffungs- und Betriebskosten, die Möglichkeit des prozessnahen Einsatzes, sowie besonders der einfachen Bedienung zum Tragen. Während es zahlreiche Beispiele von Online-Applikationen im Labor gibt, ist die direkte Einbindung in großtechnische Produktionsanlagen bislang selten. Im Vergleich zu etablierten prozessanalytischen Verfahren, wie z.B. der Nahinfrarot- oder Raman-Spektroskopie ist die Benchtop-NMR-Spektroskopie noch Neuland und es existieren kaum prozesstaugliche kommerzielle Lösungen. Im Rahmen eines gemeinsamen Entwicklungsprojekts zwischen BAM und Evonik wurde eine Einhausung für ein handelsübliches Benchtop-NMR-Spektrometer konzipiert und gebaut. Diese dient nicht nur der Erfüllung sicherheitstechnischer Auflagen wie dem Explosionsschutz, sondern auch der Abschirmung rauer Umgebungseinflüsse auf den Betrieb des Laborgeräts. Eine flexible integrierte Automatisierung ermöglicht die skalierbare Anbindung an übergeordnete Prozessleittechnik im Sinne eines PAT-Moduls. Dieser Vortrag gibt einen Überblick über die Herausforderungen auf dem Weg von der Idee, über die Umsetzung bis hin zur tatsächlichen Prozessintegration. T2 - 47. Praktische Probleme der Kernresonanzspektroskopie CY - Göttingen, Germany DA - 17.03.2026 KW - Prozessanalytik KW - NMR Spektroskopie KW - Feldintegration KW - Explosionsschutz PY - 2026 AN - OPUS4-65705 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pérez-Padilla, Víctor A1 - Burnage, Samual C. A1 - Wittwer, Philipp A1 - Valderrey, Virginia A1 - Bell, Jérémy A1 - Gawlitza, Kornelia A1 - Rurack, Knut T1 - Detection of Perfluoroalkylic Acids From Water Using a Guanidine-Based Fluorescent Probe and Microfluidic Droplet Extraction N2 - Perfluoroalkylic acids (PFAAs), a subclass of per- and polyfluoroalkyl substances (PFAS), are stable, widely used industrial compounds posing environmental concerns due to their persistence and toxicity. Regulatory actions and remediation strategies necessitate effective onsite analytical methods for PFAS management. We developed an optical sensing system using a fluorescent probe with a benzoxadiazole core and guanidine receptor in a droplet-based microfluidic assay to detect PFAAs in water samples with low detection limits. The PFAAs binding enhances the probe's fluorescence in organic media through protonation-mediated hydrogen bond-assisted ion pairing, exploiting two complementary supramolecular forces. Direct detection employs a liquid-liquid extraction protocol in the microfluidic device, achieving detection limits for PFOA and PFOS down to ≥0.5 µm, with a dynamic range up to 200 µm for sample volumes <100 µL. HCl/KCl buffering facilitates analyte desalting and phase transfer for quantitation from surface water. Additionally, we developed a method involving a thin polymer layer of the probe and a crosslinker on submicron silica particles for direct detection of PFAAs in water. Our approaches provide sensitive, direct recognition and indication of PFAAs, advancing the field beyond indirect sensing and offering improved background suppression, rapid assay times, and a modular design for targeting other PFAS subclasses. KW - PFAS KW - Fluorescence KW - Microfluidics KW - Droplet Extraction PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657330 DO - https://doi.org/10.1002/adsr.70145 VL - 5 IS - 3 SP - 1 EP - 13 PB - Wiley-VCH CY - Weinheim AN - OPUS4-65733 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Devi, Sarita A1 - Goel, S. A1 - Rani, S. A1 - Schneider, Rudolf J. A1 - Rohilla, R. A1 - Kumari, Surbhi A1 - Prabhakar, N. T1 - MOF-metal nanohybrid-assisted charge transfer amplification for electrochemical biosensing of the MUC1 cancer biomarker N2 - Cancer is a severe disease characterized by high mortality and complex pathophysiology; however, its early and accurate diagnosis remains inadequate. Conventional diagnostic approaches often fall short, particularly for dense tissues, and are frequently invasive, costly, and of limited availability. This reinforces the need for a compact, economical, and ultrasensitive assay that is operationally simple and interpretable. We present an efficient electrochemical detection platform for the cancer biomarker mucin 1 (MUC1). A fluorine-doped tin oxide (FTO) surface was modified with an iron-based metal–organic framework (FeMOF) intercalated with palladium nanorods (PdNR). FeMOF was prepared using Fe3+/Fe2+ precursors at a 1.2/1 mmol ratio and dual ligands, i.e. tetrahydroxy-1,4-benzoquinone and 2-aminobenzene-1,4-dicarboxylic acid. AntiMUC1 antibodies were immobilized on a modified electrode via p-phenylenediamine (PDA) (FTO/FeMOF@PdNR/PDA/antiMUC1Ab) and evaluated using electrochemical impedance spectroscopy (EIS) and voltammetry. The designed sensor demonstrated an excellent binding affinity for the MUC1 antigen. Among these techniques, the EIS method stands out for its technical performance, as evidenced by the high sensitivity (detection limit 0.074 fg mL−1), quantification limit 0.24 fg mL−1, and high analytical sensitivity (1.39 × 103 Ω fg−1 mL−1 cm−2). The negligible cross-reactivity with interferent biomolecules, rapid response (10-minute equilibrium), regenerability up to 5 cycles, high reproducibility (RSD ∼1–3%), and long-term stability (up to 35 days) further validate the suitability of the proposed MUC1 immunosensor. This study presents an ultrasensitive biosensor that is compact, cost-effective, and easy for individuals at home to use after further development into a kit-based end product. Moreover, its excellent functionality for spiked serum samples shows promise for next-generation clinical diagnostics. KW - Antibodies KW - Metal-organic framework KW - Immunoassay PY - 2026 DO - https://doi.org/10.1039/D6AN00018E SP - 1 EP - 11 PB - Royal Society of Chemistry CY - London AN - OPUS4-65726 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A1 - Bierkandt, Frank A1 - Rades, Steffi A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Sample loss in asymmetric flow field-flow fractionation coupled to inductively coupled plasma-mass spectrometry of silver nanoparticles N2 - In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study. KW - Asymmetric flow filed-flow fractionation KW - ICP-MS KW - Nanoparticles KW - Sample loss KW - Quantification PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-336171 DO - https://doi.org/10.1039/c5ja00297d SN - 0267-9477 SN - 1364-5544 VL - 30 IS - 10 SP - 2214 EP - 2222 PB - Royal Society of Chemistry CY - London AN - OPUS4-33617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fink, Friedrich A1 - Emmerling, Franziska A1 - Falkenhagen, Jana T1 - Identification and Classification of Technical Lignins by means of Principle Component Analysis and k-Nearest Neighbor Algorithm N2 - The characterization of technical lignins is a key step for the efficient use and processing of this material into valuable chemicals and for quality control. In this study 31 lignin samples were prepared from different biomass sources (hardwood, softwood, straw, grass) and different pulping processes (sulfite, Kraft, organosolv). Each lignin was analysed by attenuated total reflectance Fourier transform infrared (ATR-FT-IR) spectroscopy. Statistical analysis of the ATR-FT-IR spectra by means of principal component analysis (PCA) showed significant differences between the lignins. Hence, the samples can be separated by PCA according to the original biomass. The differences observed in the ATR-FT-IR spectra result primarily from the relative ratios of the p-hydroxyphenyl, guaiacyl and syringyl units. Only limited influence of the pulping process is reflected by the spectral data. The spectra do not differ between samples processed by Kraft or organosolv processes. Lignosulfonates are clearly distinguishable by ATR-FT-IR from the other samples. For the classification a model was created using the k-nearest neighbor (k NN) algorithm. Different data pretreatment steps were compared for k=1…20. For validation purposes, a 5-fold cross-validation was chosen and the different quality criteria Accuracy (Acc), Error Rate (Err), Sensitivity (TPR) and specificity (TNR) were introduced. The optimized model for k=4 gives values for Acc = 98.9 %, Err = 1.1 %, TPR = 99.2 % and TNR = 99.6 %. KW - Classification KW - PCA KW - K-nearest neighbor KW - FT-IR KW - Technical lignin PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-533855 DO - https://doi.org/10.1002/cmtd.202100028 VL - 1 IS - 8 SP - 350 EP - 396 PB - Wiley-VCH GmbH AN - OPUS4-53385 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Weidner, Steffen T1 - ROP of L-lactide and ε-caprolactone catalyzed by tin(ii) andtin(iv) acetates–switching from COOH terminated linear chains to cycles N2 - The catalytic potential of tin(II)acetate, tin(IV)acetate, dibutyltin-bis-acetate and dioctyl tin-bis-acetate was compared based on polymerizations of L-lactide conducted in bulk at 160 or 130°C. With SnAc2 low-Lac/Cat ratios (15/1–50/1) were studied and linear chains having one acetate and one carboxyl end group almost free of cyclics were obtained. Higher monomer/catalyst ratios and lower temperatures favored formation of cycles that reached weight average molecular weights (Mw's) between 100,000 and 2,500,000. SnAc4 yielded mixtures of cycles and linear species under all reaction conditions. Dibutyltin- and dioctyl tin bis-acetate yielded cyclic polylactides under most reaction conditions with Mw's in the range of 20,000–80,000. Ring-opening polymerizations performed with ε-caprolactone showed similar trends, but the formation of COOH-terminated linear chains was significantly more favored compared to analogous experiments with lactide. The reactivity of the acetate catalysts decreased in the following order: SnAc2> SnAc4>Bu2SnAc2~Oct2SnAc2 KW - Polylactide KW - MALDI-TOF MS KW - Catalyst KW - Ring-opening polymerization KW - Tin acetates PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-521923 DO - https://doi.org/10.1002/pol.20200866 VL - 59 IS - 5 SP - 439 EP - 450 PB - Wiley Online Library AN - OPUS4-52192 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Scheliga, F. A1 - Weidner, Steffen T1 - What does conversion mean in polymer science? N2 - The definition of the term “conversion” is discussed for a variety of polymer syntheses. It is demonstrated that in contrast to organic and inorganic chemistry several different definitions are needed in polymer science. The influence of increasing conversion on structure and topology of homo- and Copolymers is illustrated. Chain-growth polymerizations, such as radical polymerization or living anionic polymerizations of vinyl monomers, condensative chain polymerization, two and three-dimensional step-growth polymerizations, ring–ring or chain–chain equilibration and chemical modification of polymers are considered. KW - Polymers KW - Polymerization KW - Conversion KW - Polycondensation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-523597 DO - https://doi.org/10.1002/macp.202100010 VL - 222 IS - 8 SP - 10 PB - Wiley VCH AN - OPUS4-52359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -