TY - CONF A1 - Kalbe, Ute A1 - Krüger, Oliver A1 - Bandow, Nicole A1 - Geburtig, Anja ED - Reichert, Thomas T1 - Laboratory Weathering Test for Simulating the Leaching from Artificial Sporting Grounds N2 - In order to estimating the amount and kind of emissions from polymeric sporting tracks a laboratory test was developed in BAM that combines artificial weathering and subsequent batch and column tests [1, 2, 3]. The goal consisted in nvestigating a possible change of emissions into soil and groundwater of a new sporting ground as a function of ageing and egradation of the system. At various stages of the weathering, the samples were removed and subjected to especially designed column extraction tests for the solid samples. Both these extracts and the accumulated rainwater run-off of the weathering device were subjected to analytical tests of their ingredients. The overall aim of the test consisted in developing ontrollable, reproducible, and standardisable conditions and methods of investigation that would allow an estimation of the emissions in the course of outdoor application of about five years. T2 - 7th European Weathering Symposium. Natural and Artificial Ageing of Polymers CY - Naples, Italy DA - 16.09.2015 KW - artificial weathering KW - emission KW - leaching KW - sporting track KW - degradation KW - ageing KW - rubber KW - extraction PY - 2015 SN - 978-3-9816286-6-1 VL - CEES 17 SP - 195 EP - 208 PB - Thomas Würtz CY - Karlsruhe, Germany AN - OPUS4-35401 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - McSAS for SAS analysis: Usage, Benefits and Potential Pitfalls N2 - An introductory lecture for users at the Diamond Light Source, on how to use the McSAS software to analyze their data. T2 - Small Angle Scattering Training School CY - Diamond Light Source, Didcot, United Kingdom DA - 04.06.2018 KW - Small-angle scattering KW - Software KW - Analysis PY - 2018 AN - OPUS4-46517 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Battistella, Beatrice A1 - Revill, Adam A1 - Venzago, Cornel A1 - Hoffmann, Volker A1 - Agudo Jácome, Leonardo A1 - Al-Sabbagh, Dominik A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique T1 - Depth-Resolved Lithium Isotope Fractionation as a Diagnostic of Interphase Evolution and Degradation in Lithium Ion Batteries N2 - Lithium isotopic fractionation is well-established in dynamic geochemical systems; however, its role in lithium-ion batteries (LIBs) remains uninvestigated. Herein, we report the first depth-resolved demonstration that isotopic separation occurs during Li-ion cell operation whose magnitude depends on the cycling history. Using depth-resolved glow discharge mass spectrometry, we monitored the 7Li/6Li ratio in LiNi0.333Mn0.333Co0.333O2 (NMC111)||graphite coin cell electrodes at defined life-cycle stages. Different charging rates were examined to get mechanistic insight into kinetic and thermodynamic control in the fractionation process. Although pristine electrodes exhibit a uniform isotopic ratio, cycled electrodes show a distinct 7Li enrichment in the positive electrode and a corresponding accumulation of 6Li at the surface of the negative electrode. The degree of isotopic separation varies with the charging rate. Isotopic signatures correlate with capacity fading, indicating lithium isotope mapping as a sensitive diagnostic tool for tracking electrode degradation and the evolution of the electrode–electrolyte interphases in LIBs. KW - Li-ion batteries KW - Lithium isotopes KW - Post-mortem analysis KW - GD-MS KW - Depth profile KW - Mass spectrometry PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651287 DO - https://doi.org/10.26434/chemrxiv-2025-5rvlk SP - 1 EP - 19 AN - OPUS4-65128 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Vogl, Jochen A1 - Pritzkow, Wolfgang ED - Vanhaecke, F. ED - Degryse, P. T1 - Reference materials in isotopic analysis N2 - The production of isotopic reference materials (IRMs), which started in the 1960s, has stagnated during the last 15 years. On the other hand, the need for IRMs increased strongly with upcoming ICP-MS techniques, especially with MC instruments, in the beginning of the millennium. In parallel, the precision of the isotope amount ratio determinations reached a level which is beyond that of IRMs certified relying on synthetic isotope mixtures. Additionally, the number of elements for which IRMs are required has increased. This difference between the users’ needs and the limitations of current IRMs can only be solved by providing IRMs defining a δ-scale for each element of interest. Such δ-RMs should be produced as solutions to avoid any complications with homogeneity issues. Whenever possible, isotope amount fractions should be provided additionally, even if the uncertainties are not sufficient for cutting-edge research on isotopic variations. Research should also focus on ways to provide isotope amount fractions with lower uncertainties. For the coming years, around 27 elements have been selected by user communities as "of interest” in this context. These elements are of interest to geo- and cosmochemists, and also to scientists working in the fields of human nutrition, human medicine, veterinary medicine, and food traceability. For 18 elements, such as Pb and U, IRMs or δ-RMs are available, provided as a solution or a solid material with sufficient homogeneity. Nevertheless, in some cases further materials are necessary, because the number of units is too small or the materials are too expensive to be widely accepted by users. At BAM, IRMs and δ-RMs will be produced according to the requirements mentioned above. NIST has also started a program to produce new RMs for δ-values. As discussed at the latest meeting of the IUPAC Commission on Isotopic Abundances and Atomic Weights (CIAAW) in July 2009 in Vienna, these activities will be supported by IUPAC. KW - ICPMS KW - IRM KW - Reference materials KW - Delta reference materials PY - 2012 SN - 978-3-527-32896-3 SN - 978-3-527-65048-4 DO - https://doi.org/10.1002/9783527650484.ch6 SP - 139 EP - 163 PB - Wiley-VCH CY - Weinheim AN - OPUS4-26102 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Raab, Christopher A1 - Flemig, Sabine A1 - Döring, Sarah A1 - Ponader, Marco A1 - Thurmann, Melinda A1 - Paul, Martin A1 - Weller, Michael G. T1 - Simplified Sample Preparation and Lateral Flow Immunoassay for the Detection of Plant Viruses N2 - Lateral flow immunoassays (LFAs) are widely used for on-site testing; however, their use for the rapid detection of plant viruses in the field is often limited by inconvenient sample preparation. Here, we present a new sampling method and a simplified dipstick LFA format for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employs a monoclonal mouse antibody for capture and a poly-clonal rabbit antibody conjugated to 80 nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody–gold conjugate. No plastic casing was required, which could lead to a reduction in waste. It was shown that CCMV concentrations as low as 3.5 µg/L or 350 pg per sample could be reliably detected in 15 min. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false-positive results. In addition, we describe a new method for on-site sampling using a manual punch and a syringe equipped with a frit. This step combines grinding the sample, extraction, filtration, and reconstitution and mixing of the antibody-gold conjugate, enabling the analysis of punched leaf disks without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture. N2 - Lateral-Flow-Immunoassays (LFAs) werden häufig für Vor-Ort-Tests eingesetzt; ihr Einsatz zum schnellen Nachweis von Pflanzenviren im Feld wird jedoch oft durch eine umständliche Probenvorbereitung eingeschränkt. Hier stellen wir eine neue Probenahmemethode und ein vereinfachtes Dipstick-LFA-Format zum Nachweis und zur Überwachung des Cowpea Chlorotic Mottle Virus (CCMV) als Modellpflanzenpathogen vor. Der Test verwendet einen monoklonalen Maus-Antikörper zur Bindung und einen polyklonalen Kaninchen-Antikörper, der an 80-nm-Goldnanopartikel konjugiert ist, zum Nachweis. Herkömmliche Proben- und Konjugatpads entfallen, sodass die Teststreifen direkt in Vertiefungen getaucht werden können, die Pflanzenextrakt und das Antikörper-Gold-Konjugat enthalten. Es ist keine Kunststoffhülle erforderlich, was zu einer Reduzierung des Abfallaufkommens führen könnte. Es zeigte sich, dass CCMV-Konzentrationen von nur 3,5 µg/L oder 350 pg pro Probe innerhalb von 15 Minuten zuverlässig nachgewiesen werden konnten. Spezifitätstests bestätigten, dass andere Pflanzenviren, das Cowpea Mosaic Virus (CPMV) und das Tobacco Mosaic Virus (TMV), keine falsch-positiven Ergebnisse lieferten. Darüber hinaus beschreiben wir eine neue Methode zur Probenahme vor Ort unter Verwendung eines manuellen Lochers und einer mit einer Fritte ausgestatteten Spritze. Dieser Schritt kombiniert das Zerkleinern der Probe, die Extraktion, die Filtration sowie die Rekonstitution und das Mischen des Antikörper-Gold-Konjugats und ermöglicht so die Analyse der ausgestanzten Blattscheiben ohne Laborausrüstung. Bei der Anwendung an mit CCMV infizierten Augenbohnenpflanzen zeigte der Assay eine systemische Infektion, bevor visuelle Symptome erkennbar wurden. Diese Arbeit zeigt, dass vereinfachte LFAs in Kombination mit innovativen Probenahmetechniken eine sensitive, spezifische und schnelle Diagnostik für die Pflanzenüberwachung bieten und Strategien zur frühzeitigen Intervention in der Landwirtschaft unterstützen können. KW - Point-of-care diagnostics KW - Dipstick immunoassay KW - Pre-symptomatic detection KW - Precision agriculture KW - Integrated pest management KW - Crop health monitoring PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657039 DO - https://doi.org/10.3390/bios16020100 SN - 2079-6374 VL - 16 IS - 2 SP - 1 EP - 16 PB - MDPI AG CY - Basle, Switzerland AN - OPUS4-65703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Herter, Sven-Oliver T1 - Quantifizierung von Mutterkornalkaloiden in Lebensmitteln unter Verwendung neu entwickelter stabil isotopenmarkierter interner Standards N2 - Mutterkornalkaloide sind Mykotoxine, die von Pilzen der Gattung Claviceps produziert werden und häufig in Roggen- und Weizenprodukten vorkommen. Aufgrund ihrer toxikologischen Relevanz hat die Europäische Union im Jahr 2022 erstmals Grenzwerte für diese Alkaloide in Lebensmitteln eingeführt. Eine zuverlässige Quantifizierung ist essenziell für die Überwachung der Lebensmittelsicherheit. Allerdings stellte der bisherige Mangel an stabilen isotopenmarkierten (SIL - stable isotopically labeled) Standards eine wesentliche Herausforderung für die Entwicklung präziser Analysemethoden mittels HPLC-MS/MS dar. Um diese Lücke zu schließen, wurden erstmals alle zwölf prioritären Mutterkornalkaloide über einen einheitlichen Semisyntheseansatz als 13CD3-markierte Analoga synthetisiert und als interne Standards für die massenspektrometrische Analyse eingesetzt. Die Quantifizierung erfolgte mittels HPLC-MS/MS in verschiedenen Lebensmittelmatrizes, darunter Brot, Roggen- und Weizenmehl sowie Kleie. Zur Evaluierung der SIL-Standards wurden etablierte Methoden wie externe Kalibrierung und Standardaddition herangezogen. Die Studienergebnisse zeigen, dass der Einsatz von SIL-Standards die Genauigkeit und Präzision der Mutterkornalkaloid-Quantifizierung signifikant verbessert. Dies ist insbesondere auf die Korrektur von Matrixeffekten, Extraktions- und Signalschwankungen während der massenspektrometrischen Analyse zurückzuführen. Die neu synthetisierten 13CD3 markierten Mutterkornalkaloide stellen daher ein wertvolles Werkzeug zur Verbesserung der Lebensmittelsicherheit dar, da sie zuverlässigere und reproduzierbare Messergebnisse ermöglichen. Darüber hinaus leisten diese Ergebnisse einen wichtigen Beitrag zur Weiterentwicklung analytischer Methoden zur Überwachung von Mutterkornalkaloiden und damit zur Sicherstellung der Lebensmittelqualität. T2 - 53. Deutsche Lebensmittelchemietage CY - Halle (Saale), Germany DA - 22.09.2025 KW - HPLC-MS/MS KW - Interner Standard KW - Qualitätssicherung PY - 2025 AN - OPUS4-64546 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Henning, Thorsten A1 - Goerdeler, Cornelius A1 - El-Khatib, Ahmed H. A1 - Meyer, Klas A1 - Bruer, Gustav G. A1 - Abraham, Klaus A1 - Monien, Bernhard T1 - Characterization and quantitation of urinary metabolites of 3-monochloropropane-1,2-diol (3-MCPD) in rats N2 - Fatty acid esters of 3-monochloropropane-1,2-diol (3-MCPD) are heat-induced contaminants formed from fats and sodium chloride. The mode of action for the 3-MCPD mediated induction of renal tubule neoplasms in rats is still unclear, which is in part due to lacking metabolism data. In the current study, urinary metabolites were identified by one- and two-dimensional 13C nuclear magnetic resonance spectroscopy and high-resolution mass spectrometry following oral administration of 3-MCPD or [13C3]3-MCPD in rats. In addition to 3-MCPD itself, nine metabolites were identified. Four of those, N-acetyl-S-(2,3-dihydroxypropyl)cysteine (DHPMA), 3-MCPD sulfate, β-chlorolactic acid (β-ClLA) and oxalic acid have been reported before. Five novel metabolites in rat urine were thiodiglycolic acid (TDGA), thionyldiglycolic acid (TNDGA), 3-MCPD glucuronide (at least three isomers), 3-carboxy-2-hydroxypropyl mercapturic acid (CHPMA), and 3-(S-carboxymethyl)mercaptolactic acid (CMMLA). Only three metabolites were excreted at mean dose ratios > 1% (after treatment with 50 mg 3-MCPD/kg body weight in male and female rats), i.e. 3-MCPD (7.3%, 9.7%), DHPMA (3.5%, 1.7%) and TDGA (1.1%, 4.0%). The overall mean dose excretion in urine samples (males: 12.2%, females: 16.3%) supported hypotheses on formation of conjugates/adducts of reactive metabolites and the possibility that dechlorination leads to suitable building blocks for amino acid and fatty acid synthesis. The identification of TDGA indicated the interim formation 2-chloroacetaldehyde, previously identified to mediate specific nephrotoxic effects of the cytostatic ifosfamide in rats. KW - 3-Monochloropropane-1,2-diol KW - 3-MCPD KW - Metabolism KW - Urine PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657230 DO - https://doi.org/10.1007/s00204-026-04318-x SP - 1 EP - 17 PB - Springer-Verlag GmbH CY - Heidelberg AN - OPUS4-65723 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Altmann, Korinna A1 - Abusafia, A A1 - Bannick, C-G A1 - Braun, U A1 - Crasselt, Claudia A1 - Dittmar, S A1 - Fuchs, M A1 - Gehde, M A1 - Hagendorf, C A1 - Heller, C A1 - Herper, D A1 - Heymann, S A1 - Kerndorff, A A1 - Knefel, M A1 - Jekel, M A1 - Lelonek, M A1 - Lunkenbein, T A1 - Obermaier, N A1 - Manhart, M A1 - Meurer, Maren A1 - Miclea, P-T A1 - Paul, A A1 - Richter, S A1 - Ricking, M A1 - Rohner, C A1 - Ruhl, A A1 - Sakai, Y A1 - Saravia Arzabe, C A1 - Scheid, C A1 - Schmitt, M A1 - Schnarr, M A1 - Schwertfirm, F A1 - Steinmetz, H A1 - Wander, Lukas A1 - Wiesner, Yosri A1 - Zechmeister, L T1 - RUSEKU - Repräsentative Untersuchungsstrategien für ein integratives Systemverständnis von spezifischen Einträgen von Kunststoffen in die Umwelt : Abschlussbericht N2 - Im Verbundprojekt RUSEKU wurde die Probenahme von Wasserproben entscheidend weiterentwickelt. Wichtig ist hierbei zu gewährleisten, dass genügend Merkmalsträger in jeder Probe untersucht werden. Es muss daher eine für den Probenahmeort repräsentative Beprobung hinsichtlich des Wasservolumens in Abhängigkeit der Partikelanzahl gewährleistet sein. Das Hauptaugenmerk lag im vorliegenden Projekt auf einer praxisnahen Beprobungsstrategie. Es wurden verschiedene Konzepte ausprobiert. • Grundsätzlich hat sich gezeigt, dass eine Stichprobe eine Momentaufnahme des MP-Massengehaltes zeigt. Es wird eine hohe Statistik, also eine Vielzahl an Messungen am gleichen Probenahmeort, benötigt, um eine valide Aussage über den MP-Gehalt zu machen. • Es zeigt sich, dass eine integrale Probenahme über mehrere Wochen mit dem SK routinemäßig möglich ist. Die erfassten MP-Massen sind reproduzierbar und robust. • Die DFZ ist für Stichproben geeignet. Partikel < 50 µm werden eventuell unterschätzt • Die fraktionierte Filtration kann für Stich- und Mischproben direkt im Feld genutzt werden. Fraktionen von 10 und 5 µm werden später im Labor Vakuum filtriert. Es erfolgt eine Fraktionierung der Probe mit Siebmaschenweiten von 1000, 500, 100, 50, 10 und 5 µm. • Die fraktionierte Filtration kann auch anschließend an die Beprobung mit dem SK zur Anwendung kommen. Wird die mit dem SK gewonnene Wasserprobe fraktioniert filtriert, kann neben einem MP-Gesamtgehalt auch eine Einschätzung über die Partikelgrößen gewonnen werden. • Für Wässer mit geringen Partikelzahlen wurde ein Messfiltertiegel entwickelt. Dieser hat eine Maschenweite von 6 µm. Seine Anwendung kann mögliche Verluste beim Transferieren vom Probenahmetool zum Messgefäß und mögliche Kontaminationen reduzieren. Die Optimierung der Probenahmestrategie wurde durch Modellversuche und Simulationen unterstützt. Modellversuche zum Sinkverhalten und Simulationen von MP in realen Gewässern verdeutlichten das komplexe Verhalten der Partikel. Es konnte gezeigt werden, dass Partikel ab einer bestimmten Größe (und kleiner) bei genügend starker Turbulenz sich in der Wassersäule unabhängig von ihrer Dichte verhalten und so auch MP mit kleiner Dichte (z.B. PE) in der gesamten Wassersäule zu finden sind. Es konnte mit dem TEM die Existenz von NP gezeigt werden. Ein wesentlicher Aspekt des RUSEKU Projektes war die Beprobung realer Kompartimente. Beprobt wurde neben Oberflächengewässern, das urbane Abwassersystem der Stadt Kaiserslautern, Waschmaschinenabwasser und Flaschenwasser. • In Oberflächengewässern wurde hauptsächlich PE gefunden. Je nach Probe und Gewässer konnten auch PP, PS, PET, PA, SBR und Acrylate nachgewiesen werden. • Im urbanen Abwassersystem der Stadt Kaiserslautern konnte an allen Probenahmestandorten MP nachgewiesen werden. Es wurde hauptsächlich PE, neben geringeren Mengen an PP, PS und SBR gefunden. Nach einem Regenereignis war der SBR Anteil deutlich erhöht. • Die Beprobung eines realen Wäschepostens, bestehend aus T-Shirts und Hemden mit PA/CO oder PES/CO Mischgewebe, zeigte einen PA- und PES-Austrag im Waschwasser. Der überwiegende Teil der detektierten Fasern ist aber auf Baumwolle zurückzuführen. Reine gravimetrische Messungen zur Detektion von MP führen zu einer starken Überschätzung. • In Flaschenwasser (PET-Flaschen) konnte MP detektiert werden. PET wurde nur im stillen Mineralwasser, nicht in Mineralwasser mit Kohlensäure gefunden werden. Teilweise wurde auch das MP-Material des Verschlusses im Wasser detektiert. • Für Luftproben konnte ein Aufbau zur größenselektiven Beprobung getestet werden. Neben der Probenahme hat das Projekt auch gezeigt, dass die TED-GC/MS geeignet für die MP-Detektion im Routinebetrieb ist. Die TED-GC/MS konnte weiter optimiert werden. Es wurden MP-Massen bestimmt. Im Projekt wurden erste realitätsnahe Referenzmaterialien für die MP Detektion hergestellt. Die Herstellung von realitätsnahen Polymeren in ausreichender Homogenität und Menge hat sich als große Herausforderung herausgestellt. KW - Mikroplastik KW - Probennahme KW - TED-GC/MS KW - Fraktionierte Filtration KW - Mikroplastikreferenzmaterial PY - 2022 SP - 1 EP - 201 AN - OPUS4-57800 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Emmerling, Franziska T1 - In situ studies of mechanochemistry: a force of synthesis N2 - Recent results in the field of mechanisms and kinetics of mechanochemical reactions. T2 - Seminar GFZ Potsdam CY - Postdam, Germany DA - 28.03.2018 KW - In situ KW - XRD KW - Rietveld PY - 2018 AN - OPUS4-46992 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Detektion von Kunststoffen mittels TED-GC-MS N2 - Vortrag zur Funktionsweise der TED-GC-MS für die Analyse von Mikroplastik in Umweltproben T2 - Arbeitsgespräch der Ressortforschungseinrichtungen CY - Berlin, Germany DA - 26.11.2018 KW - Mikroplastik KW - TED-GC-MS PY - 2018 AN - OPUS4-47184 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Emmerling, Franziska T1 - New insights in mechanochemical processes using real-time In situ investigations N2 - Mechanochemistry is a fast and efficient method applicable for the synthesis of new organic[1], metal-organic[2], and inorganic[3] compounds. The direct monitoring of milling reactions is still challenging. The underlying reaction mechanisms remain often unclear. In the last years, have established a tandem in situ approach for investigating mechanochemical reactions using time-resolved in situ XRD coupled with Raman spectroscopy.[4] Here, we present an in situ coupling of synchrotron XRD, Raman spectroscopy, and thermography allowing the observation of mechanochemical reactions in real time.[5] Information on the crystalline, molecular, and temperature state of the materials during grinding could be collected. The chemical composition of the reaction mixture was found to be directly correlated with changes in the temperature profile of the reaction. Furthermore, the presented setup allows the detection of crystalline, amorphous, eutectic as well as liquid intermediates. The resulting deeper kinetic and thermodynamic understanding of milling processes is the key for future optimization of mechanochemical syntheses. T2 - 5th International Conference "Fundamental Bases of Mechanochemical Technologies" CY - Novosibirsk, Russia DA - 25.06.2018 KW - Mechanochemistry KW - XRD KW - Kinetic KW - Coordination polymers PY - 2018 AN - OPUS4-46994 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Akhmetova, Irina T1 - Mechanochemical synthesis of metal phosphonates N2 - The exploration of metal phosphonates chemistry has gained great interest during the last decades, because of their structural diversity. Transition metal phosphonates are promising candidates for an application as electrocatalysts in oxygen evolution reactions (OER). Here, we present the in situ investigation of mechanochemical syntheses of different manganese phosphonates by synchrotron X-ray diffraction. Nitrilotri(methylenephosphonic acid) and N,N-Bis(phosphonomethyl)glycine were chosen as ligands. The liquid-assisted milling process can be divided into three steps, including an amorphous stage. One of the products has not been obtained by classical solution chemistry before. These metal phosphonates and/or their derivatives are considered to be active in electrochemical energy conversion. The verification of their applicability is one of the topics of our resent research. T2 - Fundamental Bases of Mechanochemical Technologies CY - Novosibirsk, Russia DA - 25.06.2018 KW - Metal phosphonates KW - Mechanochemistry KW - PXRD KW - Thermography PY - 2018 AN - OPUS4-46996 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Akhmetova, Irina T1 - In situ investigation of milling reactions and structure determination of the products using X-ray diffraction N2 - Mechanochemistry is a versatile approach for green and fast synthesis of pure substances. By milling the reactants, various organic, inorganic, and metal-organic compounds can be obtained in high yields. Although mechanochemistry is widely used, the underlying mechanisms are not fully understood making mechanochemical reactions difficult to predict. Metal phosphonates are metal-organic compounds accessible by grinding. Because of their structural diversity, the exploration of the chemistry of metal phosphonates has gained considerable interest during the last decades. Transition metal phosphonates are promising candidates for an application as electrocatalysts in oxygen evolution reaction (OER). Here, we present the in situ investigation of the mechanochemical synthesis of a manganese(II)-phosphonate by synchrotron X-ray diffraction and thermography. The product has not been obtained by classical solution chemistry before and its crystal structure was determined from PXRD data. The milling process can be divided into different steps, with the product crystallization corresponding with the highest temperature rise. The activity of this metal phosphonate towards OER was measured and is presented here. T2 - International School of Crystallography - 52nd Course: Quantum Crystallography CY - Erice, Italy DA - 1.06.2018 KW - Metal phosphonates KW - Mechanochemistry KW - PXRD KW - OER KW - Thermography PY - 2018 AN - OPUS4-46998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lauer, Franziska A1 - Diehn, Sabrina A1 - Seifert, Stephan A1 - Kneipp, Janina A1 - Sauerland, V. A1 - Barahona, C. A1 - Weidner, Steffen T1 - Multivariate analysis of MALDI imaging mass spectrometry data of mixtures of single pollen grains N2 - Mixtures of pollen grains of three different species (Corylus avellana, Alnus cordata, and Pinus sylvestris) were investigated by matrixassisted laser desorption/ionization time-of-flight imaging mass spectrometry (MALDI-TOF imaging MS). The amount of pollen grains was reduced stepwise from > 10 to single pollen grains. For sample pretreatment, we modified a previously applied approach, where any additional extraction steps were omitted. Our results show that characteristic pollen MALDI mass spectra can be obtained from a single pollen grain, which is the prerequisite for a reliable pollen classification in practical applications. MALDI imaging of laterally resolved pollen grains provides additional information by reducing the complexity of the MS spectra of mixtures, where frequently peak discrimination is observed. Combined with multivariate statistical analyses, such as principal component analysis (PCA), our approach offers the chance for a fast and reliable identification of individual pollen grains by mass spectrometry. KW - MALDI Imaging MS KW - Pollen grains KW - Multivariate Statistics KW - Hierarchical cluster analysis KW - Principal component analysis PY - 2018 DO - https://doi.org/10.1007/s13361-018-2036-5 SN - 1044-0305 SN - 1879-1123 VL - 29 IS - 11 SP - 2237 EP - 2247 PB - Springer AN - OPUS4-45607 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Glimpses of the Future : Oh my god it’s full of metadata! N2 - In this talk, the importance of metadata is underscored by real-world examples. Metadata is essential to alleviating the reproducibility crises in science. This imples that a wide range of metadata must be collected, with a heavy emphasis on the automated collection of such metadata. This must subsequently be organized in an intelligible, archival structure, when possible with units and uncertainties. Such metadata can aid in improving the usage efficiency of instrumentation, as is demonstrated on the MOUSE instrument. This metadata can now be used to connect the various aspects of the holistic experimental procedure to gain better insights on the materials structure. A second example shows the extraction and organization of such metadata from an automated materials development platform, collected during the synthesis of 1200 samples. These metadata from the synthesis can then be linked to the results from the analysis of these samples, to find direct correlations between the synthesis parameters and the final structure of the materials. T2 - Helmholtz Incubator Summer Academy - Next Level Data Science CY - Online meeting DA - 18.09.2023 KW - Metadata KW - Lab automation KW - Data provenance KW - High-throughput KW - Correlative analysis KW - MOUSE KW - X-ray scattering KW - Robotics PY - 2023 AN - OPUS4-58463 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard A1 - Laskina, Sofya A1 - Naik, Aakash A1 - Smales, Glen Jacob A1 - George, Janine A1 - Breßler, Ingo A1 - Benner, Philipp T1 - Jupyter notebook and VASP calculation details accompanying the manuscript: "Ultima Ratio: Simulating wide-range X-ray scattering and diffraction" N2 - Summary: This notebook and associated datasets (including VASP details) accompany a manuscript available on the ArXiv (https://doi.org/10.48550/arXiv.2303.13435) and hopefully soon in a journal as short communication as well. Most of the details needed to understand this notebook are explained in that paper with the same title as above. For convenience, the abstract is repeated here: Paper abstract: We demonstrate a strategy for simulating wide-range X-ray scattering patterns, which spans the small- and wide scattering angles as well as the scattering angles typically used for Pair Distribution Function (PDF) analysis. Such simulated patterns can be used to test holistic analysis models, and, since the diffraction intensity is presented coupled to the scattering intensity, may offer a novel pathway for determining the degree of crystallinity. The "Ultima Ratio" strategy is demonstrated on a 64-nm Metal Organic Framework (MOF) particle, calculated from $Q<0.01$\,$\mathrm{nm}^{-1}$ up to $Q\approx150$\,$\mathrm{nm}^{-1}$, with a resolution of 0.16\,\AA. The computations exploit a modified 3D Fast Fourier Transform (3D-FFT), whose modifications enable the transformations of matrices at least up to $8000^3$ voxels in size. Multiple of these modified 3D-FFTs are combined to improve the low-$Q$ behaviour. The resulting curve is compared to a wide-range scattering pattern measured on a polydisperse MOF powder. While computationally intensive, the approach is expected to be useful for simulating scattering from a wide range of realistic, complex structures, from (poly-)crystalline particles to hierarchical, multicomponent structures such as viruses and catalysts. KW - X-ray KW - Simulation KW - Scattering KW - MOUSE KW - Nanomaterials KW - XRD KW - SAXS KW - PDF KW - Total scattering KW - 3D Fourier transform KW - High resolution KW - FFT PY - 2023 DO - https://doi.org/10.5281/zenodo.7764044 PB - Zenodo CY - Geneva AN - OPUS4-57207 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Döring, Sarah A1 - Wulfes, Birte S. A1 - Atanasova, Aleksandra A1 - Jaeger, Carsten A1 - Walzel, Leopold A1 - Tscheuschner, Georg A1 - Flemig, Sabine A1 - Gawlitza, Kornelia A1 - Feldmann, Ines A1 - Konthur, Zoltán A1 - Weller, Michael G. T1 - Corundum Particles as Trypsin Carrier for Efficient Protein Digestion N2 - Reusable enzyme carriers are valuable for proteomic workflows, yet many supports are expensive or lack robustness. This study describes the covalent immobilization of recombinant trypsin on micrometer-sized corundum particles and assesses their performance in protein digestion and antibody analysis. The corundum surface was cleaned with potassium hydroxide, silanized with 3-aminopropyltriethoxysilane and activated with glutaraldehyde. Recombinant trypsin was then attached, and the resulting imines were reduced with sodium cyanoborohydride. Aromatic amino acid analysis (AAAA) estimated an enzyme loading of approximately 1 µg/mg. Non-specific adsorption of human plasma proteins was suppressed by blocking residual aldehydes with a Tris-glycine-lysine buffer. Compared with free trypsin, immobilization shifted the temperature optimum from 50 to 60 °C and greatly improved stability in 1 M guanidinium hydrochloride. Activity remained above 80% across several reuse cycles, and storage at 4 °C preserved functionality for weeks. When applied to digesting the NISTmAb, immobilized trypsin provided peptide yields and sequence coverage comparable to soluble enzyme and outperformed it at elevated temperatures. MALDI-TOF MS analysis of Herceptin digests yielded fingerprint spectra that correctly identified the antibody and achieved 60% sequence coverage. The combination of low cost, robustness and analytical performance makes corundum-immobilized trypsin an attractive option for research and routine proteomic workflows. N2 - Wiederverwendbare Enzymcarrier sind für proteomische Arbeitsabläufe von großem Wert, doch viele Trägermaterialien sind teuer oder nicht robust genug. Diese Studie beschreibt die kovalente Immobilisierung von rekombinantem Trypsin auf mikrometergroßen Korundpartikeln und bewertet deren Leistungsfähigkeit beim Proteinverdau und der Antikörperanalyse. Die Korundoberfläche wurde mit Kaliumhydroxid gereinigt, mit 3-Aminopropyltriethoxysilan silanisiert und mit Glutaraldehyd aktiviert. Anschließend wurde rekombinantes Trypsin gebunden, und die entstandenen Imine wurden mit Natriumcyanoborhydrid reduziert. Die aromatische Aminosäureanalyse (AAAA) ergab eine geschätzte Enzymbeladung von etwa 1 µg/mg. Die unspezifische Adsorption von menschlichen Plasmaproteinen wurde durch Blockierung der restlichen Aldehyde mit einem Tris-Glycin-Lysin-Puffer unterdrückt. Im Vergleich zu freiem Trypsin verschob die Immobilisierung das Temperaturoptimum von 50 auf 60 °C und verbesserte die Stabilität in 1 M Guanidiniumhydrochlorid erheblich. Die Aktivität blieb über mehrere Wiederverwendungszyklen hinweg bei über 80 %, und die Lagerung bei 4 °C bewahrte die Funktionalität über Wochen hinweg. Beim Verdau des NISTmAb lieferte das immobilisierte Trypsin Peptidausbeuten und Sequenzabdeckungen, die mit denen des löslichen Enzyms vergleichbar waren, und übertraf dieses bei erhöhten Temperaturen. Die MALDI-TOF-MS-Analyse von Herceptin-Verdauen ergab Fingerabdruck-Spektren, die den Antikörper korrekt identifizierten und eine Sequenzabdeckung von 60 % erreichten. Die Kombination aus niedrigen Kosten, Robustheit und analytischer Leistungsfähigkeit macht auf Korund immobilisiertes Trypsin zu einer attraktiven Option für die Forschung und routinemäßige proteomische Arbeitsabläufe. KW - Bottom-up proteomics KW - Solid-phase digestion KW - Biopharmaceutical analysis KW - Peptide mapping KW - Non-specific binding KW - amino acid analysis PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657021 DO - https://doi.org/10.3390/biotech15010002 SN - 2673-6284 VL - 15 IS - 1 SP - 1 EP - 23 PB - MDPI CY - Basel AN - OPUS4-65702 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Singh, Chandan T1 - Oxidation resistant, interlaced 3D MXene composite for electrochemical biosensing N2 - BSA (Bovine Serum Albumin) as an oxidation resistant for Ti₃C₂Tx-MXene : BSA derived method protects 3D interlaced Ti₃C₂Tx–CNT nanocomposite from oxidative degradation, preserving their structural integrity . Application in biosensing: After the removal of excess BSA, the nanocomposite were amino-silane functionalized and decorated with anti-SARS-CoV-2 antibodies, enabling selective detection of SARS-CoV-2 nucleocapsid protein (SNP) in saliva. Performance of the biosensor: The designed biosensor showed high sensitivity (LoD 23.6 pM), wide detection range (0.1–500 ng/mL), no cross-reactivity, and improved response due to the preserved 3D interwoven nanostructure. T2 - Graphene Week 2025 CY - Vicenza, Italy DA - 22.09.2025 KW - Nanocomposite KW - Biosensor KW - SARS-CoV-2 PY - 2025 AN - OPUS4-65728 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kumari, Surbhi T1 - Tagetes erecta synthesized bimetallic Ag–Au nanoparticles and their potential application in electrochemical detection and estimation of ampicillin in raw milk N2 - This study focuses on the green synthesis of Ag–Au nanoparticles using Tagetes erecta extract and their potential application in electrochemical detection and estimation of ampicillin in raw milk. The Ag–Au nanoparticles were covalently bonded to the hydroxylated fluorine-doped tin oxide electrode surface through silane chemistry enabling the effective interaction of the 5' thiolated-aptamer with the nanoparticle-modified surface for aptasensor development. The aptasensor displayed a limit of detection of 0.40 ng mL−1 and a stability of 30 days. Moreover, the aptasensor demonstrated reliable performance with both spiked milk samples and real milk samples, detecting a concentration of 194 ng mL−1 in raw milk with results closely matching with those obtained by the LC-MS technique. T2 - SALSA Make & Measure 2025: Interfaces CY - Berlin, Germany DA - 10.09.2025 KW - Aptamer KW - Antibiotic KW - Biosensing PY - 2025 AN - OPUS4-65727 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Meyer, Klas T1 - Benchtop NMR-Spektroskopie im industriellen Produktionsumfeld: Herausforderungen auf dem Weg zur Online-Prozessintegration N2 - Benchtop-NMR Spektrometer erobern erfolgreich seit Jahren die Labore und haben sich als ein vielseitiges analytisches Werkzeug etabliert. Zunächst stark fokussiert auf den Forschungs-bereich, sind sie heute zunehmend auch nahe der Produktion auf dem Vormarsch. Die Zielstellung ist nur selten der Ersatz von klassischer „Hochfeld“-NMR-Spektroskopie. Vielmehr erschließen die kompakten Geräte oftmals neue Anwendungsfelder, beispielsweise in der Online-Reaktionsverfolgung im Labor oder der schnellen at-line Qualitätskontrolle in der chemischen Produktion. Hier kommen die Vorteile der geringeren Anschaffungs- und Betriebskosten, die Möglichkeit des prozessnahen Einsatzes, sowie besonders der einfachen Bedienung zum Tragen. Während es zahlreiche Beispiele von Online-Applikationen im Labor gibt, ist die direkte Einbindung in großtechnische Produktionsanlagen bislang selten. Im Vergleich zu etablierten prozessanalytischen Verfahren, wie z.B. der Nahinfrarot- oder Raman-Spektroskopie ist die Benchtop-NMR-Spektroskopie noch Neuland und es existieren kaum prozesstaugliche kommerzielle Lösungen. Im Rahmen eines gemeinsamen Entwicklungsprojekts zwischen BAM und Evonik wurde eine Einhausung für ein handelsübliches Benchtop-NMR-Spektrometer konzipiert und gebaut. Diese dient nicht nur der Erfüllung sicherheitstechnischer Auflagen wie dem Explosionsschutz, sondern auch der Abschirmung rauer Umgebungseinflüsse auf den Betrieb des Laborgeräts. Eine flexible integrierte Automatisierung ermöglicht die skalierbare Anbindung an übergeordnete Prozessleittechnik im Sinne eines PAT-Moduls. Dieser Vortrag gibt einen Überblick über die Herausforderungen auf dem Weg von der Idee, über die Umsetzung bis hin zur tatsächlichen Prozessintegration. T2 - 47. Praktische Probleme der Kernresonanzspektroskopie CY - Göttingen, Germany DA - 17.03.2026 KW - Prozessanalytik KW - NMR Spektroskopie KW - Feldintegration KW - Explosionsschutz PY - 2026 AN - OPUS4-65705 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pérez-Padilla, Víctor A1 - Burnage, Samual C. A1 - Wittwer, Philipp A1 - Valderrey, Virginia A1 - Bell, Jérémy A1 - Gawlitza, Kornelia A1 - Rurack, Knut T1 - Detection of Perfluoroalkylic Acids From Water Using a Guanidine-Based Fluorescent Probe and Microfluidic Droplet Extraction N2 - Perfluoroalkylic acids (PFAAs), a subclass of per- and polyfluoroalkyl substances (PFAS), are stable, widely used industrial compounds posing environmental concerns due to their persistence and toxicity. Regulatory actions and remediation strategies necessitate effective onsite analytical methods for PFAS management. We developed an optical sensing system using a fluorescent probe with a benzoxadiazole core and guanidine receptor in a droplet-based microfluidic assay to detect PFAAs in water samples with low detection limits. The PFAAs binding enhances the probe's fluorescence in organic media through protonation-mediated hydrogen bond-assisted ion pairing, exploiting two complementary supramolecular forces. Direct detection employs a liquid-liquid extraction protocol in the microfluidic device, achieving detection limits for PFOA and PFOS down to ≥0.5 µm, with a dynamic range up to 200 µm for sample volumes <100 µL. HCl/KCl buffering facilitates analyte desalting and phase transfer for quantitation from surface water. Additionally, we developed a method involving a thin polymer layer of the probe and a crosslinker on submicron silica particles for direct detection of PFAAs in water. Our approaches provide sensitive, direct recognition and indication of PFAAs, advancing the field beyond indirect sensing and offering improved background suppression, rapid assay times, and a modular design for targeting other PFAS subclasses. KW - PFAS KW - Fluorescence KW - Microfluidics KW - Droplet Extraction PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657330 DO - https://doi.org/10.1002/adsr.70145 VL - 5 IS - 3 SP - 1 EP - 13 PB - Wiley-VCH CY - Weinheim AN - OPUS4-65733 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Devi, Sarita A1 - Goel, S. A1 - Rani, S. A1 - Schneider, Rudolf J. A1 - Rohilla, R. A1 - Kumari, Surbhi A1 - Prabhakar, N. T1 - MOF-metal nanohybrid-assisted charge transfer amplification for electrochemical biosensing of the MUC1 cancer biomarker N2 - Cancer is a severe disease characterized by high mortality and complex pathophysiology; however, its early and accurate diagnosis remains inadequate. Conventional diagnostic approaches often fall short, particularly for dense tissues, and are frequently invasive, costly, and of limited availability. This reinforces the need for a compact, economical, and ultrasensitive assay that is operationally simple and interpretable. We present an efficient electrochemical detection platform for the cancer biomarker mucin 1 (MUC1). A fluorine-doped tin oxide (FTO) surface was modified with an iron-based metal–organic framework (FeMOF) intercalated with palladium nanorods (PdNR). FeMOF was prepared using Fe3+/Fe2+ precursors at a 1.2/1 mmol ratio and dual ligands, i.e. tetrahydroxy-1,4-benzoquinone and 2-aminobenzene-1,4-dicarboxylic acid. AntiMUC1 antibodies were immobilized on a modified electrode via p-phenylenediamine (PDA) (FTO/FeMOF@PdNR/PDA/antiMUC1Ab) and evaluated using electrochemical impedance spectroscopy (EIS) and voltammetry. The designed sensor demonstrated an excellent binding affinity for the MUC1 antigen. Among these techniques, the EIS method stands out for its technical performance, as evidenced by the high sensitivity (detection limit 0.074 fg mL−1), quantification limit 0.24 fg mL−1, and high analytical sensitivity (1.39 × 103 Ω fg−1 mL−1 cm−2). The negligible cross-reactivity with interferent biomolecules, rapid response (10-minute equilibrium), regenerability up to 5 cycles, high reproducibility (RSD ∼1–3%), and long-term stability (up to 35 days) further validate the suitability of the proposed MUC1 immunosensor. This study presents an ultrasensitive biosensor that is compact, cost-effective, and easy for individuals at home to use after further development into a kit-based end product. Moreover, its excellent functionality for spiked serum samples shows promise for next-generation clinical diagnostics. KW - Antibodies KW - Metal-organic framework KW - Immunoassay PY - 2026 DO - https://doi.org/10.1039/D6AN00018E SP - 1 EP - 11 PB - Royal Society of Chemistry CY - London AN - OPUS4-65726 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A1 - Bierkandt, Frank A1 - Rades, Steffi A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Sample loss in asymmetric flow field-flow fractionation coupled to inductively coupled plasma-mass spectrometry of silver nanoparticles N2 - In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study. KW - Asymmetric flow filed-flow fractionation KW - ICP-MS KW - Nanoparticles KW - Sample loss KW - Quantification PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-336171 DO - https://doi.org/10.1039/c5ja00297d SN - 0267-9477 SN - 1364-5544 VL - 30 IS - 10 SP - 2214 EP - 2222 PB - Royal Society of Chemistry CY - London AN - OPUS4-33617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -