TY - CHAP A1 - Schäferling, Michael ED - Meyers, R.A. T1 - Fluorescence-based biosensors N2 - Biosensors, as defined by Pure and Applied Chemistry, are ‘chemical sensors in which the recognition System utilizes a biochemical mechanism. The biological recognition system translates information from the biochemical domain, usually an analyte concentration, into a chemical or physical output signal with a defined sensitivity’.(1) It is also appointed that chemical or biological sensors contain two basic components connected in series: a chemical or biomolecular recognition System (receptor) and a physicochemical transducer. According to this prerequisite, this overlook is confined to sensor devices that combine a biomolecular recognition element with an optical signal transducer. Homogeneous or intracellular assays using fluorescent molecular probes or nanoparticles are not considered, although they are frequently termed as molecular sensors or nanosensors in the literature. Fluorescence-based biosensors are generalized as those devices that derive an analytical signal from a photoluminescent (either fluorescence or phosphorescence) emission process. Chemi- or bioluminescent detection systems are only briefly discussed in this review. Biosensors are used for a wide variety of tasks, including detection of compounds of biomedical, environmental or defense interest; on-line monitoring for process control; quality control of foodstuffs; selective detection of compounds undergoing a chemical separation; and screening of drug compounds. Advantages of such devices include high selectivity, rapid response times, reusability, amenability to remote analysis, and immunity to electrical interferences. The selective nature of complexation between biomolecule and analyte and the small size of sensor devices can be combined with advanced detection techiques such as total internal reflection (TIR) spectroscopy. This results in an ability to measure analytes in complex matrices with unsurpassed sensitivity. Such samples may include highly scattering components such as milk or whole blood,(11) or relatively inaccessible locations such as groundwater wells, or even intracellular environments. The key limitation of such devices mainly centers on the poor stability of biological compounds, which can lead to a substantial drift in instrumental response over time. The so-called Cambridge Definition appoints another characteristic property of sensors. Therein, they are defined as ‘miniaturized devices which can deliver real-time and on-line information on the presence of specific compounds or ions in even complex samples’. Accordingly, a sensor is expected to respond reversibly and continuously. With the exception of some enzymatic sensors, these conditions are not fulfilled in case of most biosensors. Particularly, in devices where immunological reagents or DNA are used as recognition elements, they show a lack of reversibility and operate only as a ‘one-shot’ screen, without the potential for continuous, quantitative analysis. Nevertheless, the designations immunosensors or DNA sensors became accepted for such analytical or diagnostic tools. KW - Biosensor KW - Fluorescence KW - Immunoassay KW - Enzyme sensor KW - DNA sensor PY - 2016 UR - http://onlinelibrary.wiley.com/doi/10.1002/9780470027318.a0206.pub3/abstract SN - 9780470027318 DO - https://doi.org/10.1002/9780470027318.a0206.pub3 SP - 1 EP - 51 PB - John Wiley & Sons AN - OPUS4-38741 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Gawlitza, Kornelia A1 - Wan, Wei A1 - Wagner, Sabine A1 - Rurack, Knut ED - Tiwari, Ashutosh ED - Uzun, Lokman T1 - Fluorescent Molecularly Imprinted Polymers N2 - An ideal sensor system is a combination of a selective receptor, an effective transducer, and a sensitive detector. To utilize molecularly imprinted polymers (MIPs) as responsive recognition phases in sensors, the employment of fluorescent molecules or nanoparticles (NPs) that show prominent changes in their spectroscopic properties after binding of the target molecule in the MIP’s cavity is particularly attractive. Such fluorescent MIPs (fMIPs) act through target-induced quenching, enhancement, or spectral shifts of the fluorescence. This contribution introduces different strategies of incorporation of fluorescent dyes, probes, and NPs into fMIPs. In addition, various sensing mechanisms are reviewed, and depending on the application of the sensor, the different deployable formats, their advantages, drawbacks, and impact will be presented and discussed. KW - Dyes KW - Fluorescence KW - Molecular imprinted polymers KW - Quantum dots KW - Sensors PY - 2017 SN - 978-1-119-33629-7 SP - 89 EP - 128 PB - Scrivener Publishing, WILEY CY - Beverly, MA ET - 1 AN - OPUS4-38798 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Hahn, Oliver ED - Russel-Smith, Lilla ED - Konczak-Nagel, Ines T1 - Scientific investigation in arts and and culture N2 - The investigation of cultural assets often deals with the question of provenance, dating, or attribution to artists or workshops. The analysis of physical properties and chemical composition generates important data for answering cultural-historical questions that cannot be solved by stylistic and art-historical methods alone. Starting from some wooden painted architectural elements from Kocho and one from Bezeklik (III 8592), this paper aims to give some insights into the multi-instrumental approach to the analysis of cultural artefacts. KW - Archaeometry KW - X-ray fluorescence spectroscopy KW - Raman-spectroscopy KW - VIS-spectrophotometry KW - Scanning electron microscopy PY - 2016 SN - 978-3-88609-786-9 SP - 135 EP - 142 AN - OPUS4-38817 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Hahn, Oliver ED - Gonella, Julia ED - Weis, Friederike ED - Rauch, Christoph T1 - Scientific investigation of carbon inks – an analytical challenge N2 - The investigation of physical properties and chemical composition generates data important for answering art-historical questions. Due to technological developments, technical diagnostics in art and culture are in ever-greater demand in such fields of transdisciplinary research. Based on one example, a collar drawing from the Berlin Diez albums, the present paper aims to give some insights into the multi-instrumental approach in the material analysis of cultural artefacts. The same methods were also applied to other drawings from the Diez Albums. KW - Archaeometry KW - X-ray fluorescence KW - Visible spectrophotometry KW - Non-destructive analysis PY - 2017 SN - 9789004323483 DO - https://doi.org/10.1163/9789004323483_016 VL - 11 SP - 427 EP - 438 PB - Brill CY - Leiden AN - OPUS4-38818 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Álvarez-García, J. A1 - Izquierdo-Roca, V. A1 - Pistor, P. A1 - Schmid, Thomas A1 - Pérez-Rodríguez, A. ED - Abou-Ras, D. ED - Kirchartz, T. ED - Rau, U. T1 - Raman spectroscopy on thin films for solar cells N2 - In the present chapter, the capabilities of Raman spectroscopy for the advanced characterisation of thin films for solar cells are reviewed. Raman spectroscopy is an optical, nondestructive technique based on the inelastic scattering of photons with elemental vibrational excitations in the material. The line shape and position of the Raman bands are determined by the crystalline structure and chemical composition of the measured samples, being sensitive to the presence of crystalline defects, impurities and strain. Presence of peaks characteristic of different phases also allows for the identification of secondary phases that are strongly related to the growth and process conditions of the films. All these aspects account for a strong interest in the analysis of the Raman spectra, providing a powerful nondestructive analytical tool for the structural and chemical assessment of the films. In addition, the combination of a Raman spectrometer with an optical microscope also allows for achieving a high spatial resolutions (of below 1 µm) when mapping surfaces and analyzing depth-resolved phase distributions in thin films. The present chapter is divided into four main sections: The two first ones are devoted to a revision of the Fundamentals of Raman spectroscopy (Section 17.2) and Vibrational modes in crystalline materials (Section 17.3). Section 17.4 deals with the main experimental considerations involved in the design and implementation of a Raman scattering setup. This is followed by a detailed description of the application of Raman scattering for the structural and chemico-physical analysis of thin film photovoltaic materials (Section 17.5), with the identification of crystalline structure and secondary phases, evaluation of film crystallinity, analysis of chemical composition of semiconductor alloys, characterisation of nanocrystalline and amorphous layers, stress effects and crystal orientations. This includes the description of corresponding state of the art and recent case examples that illustrate the capabilities of the Raman technique for the advanced characterisation of layers and process monitoring in thin-film photovoltaic technologies. KW - Thin-film solar cells KW - Polycrystalline materials KW - Raman spectroscopy KW - Raman microscopy PY - 2016 UR - http://eu.wiley.com/WileyCDA/WileyTitle/productCd-3527339922.html SN - 978-3-527-33992-1 SP - 469 EP - 499 PB - Wiley & Sons, Ltd. CY - Oxford, UK AN - OPUS4-37451 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Vasilic, Ksenija A1 - Geiker, M. A1 - Hattel, J. A1 - Martinie, L. A1 - Martys, N. A1 - Roussel, N. A1 - Spangenberg, J. ED - Roussel, N. ED - Gram, A. T1 - Advanced methods and future perspectives N2 - The one-phase methods described in Chapter 2 were shown to be able to predict casting to some extent, but could not depict segregation, sedimentation and blockage occurring during flow. On the other hand, the distinct element methods described in Chapter 3 did not take into account the presence of two phases in the system and describes concrete as distinct elements interacting through more or less complex laws. A reliable numerical model of a multiphase material behaviour shall take into account both phases (solid and liquid). From the numerical point of view, concrete flow shall be seen therefore as the free surface flow of a highly-concentrated suspension of rigid grains. KW - SCC KW - Numerical simulation PY - 2014 SN - 978-94-017-8883-0 DO - https://doi.org/10.1007/978-94-017-8884-7_5 VL - 15 SP - 125 EP - 146 PB - Springer Netherlands AN - OPUS4-37443 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Zscherpel, Uwe A1 - Ewert, Uwe ED - Russo, Paolo T1 - Handbook of X-ray imaging: Physics and technology N2 - Industrial Radiology is used for volumetric inspection of industrial objects. By penetration of these objects (typically weldments, pipes or castings) with X-ray or Gamma radiation the 3D-volume is projected onto a 2D image detector. The X-ray film is the oldest radiographic image detector and still in wide use in industry. The industrial X-ray film systems used today differ from these used in medicine. Medical film systems are described well in the literature, but industrial film systems not. So we start with a description of the properties and standards for industrial film systems. The requirements on image quality are defined by several standards and can be verified with different image quality indicators (IQIs). They describe the ability of the human being to detect small and low contrast indications in a noisy image background. The essential parameters for digital industrial radiology are described. Since about 30 years electronic image detectors are gradually replacing the industrial film. These detectors are based on storage phosphor imaging plates in combination with Laser scanners (“Computed Radiography”, CR) or a variety of different digital detector arrays (DDA). Typical applications of CR and DDAs are discussed as well as new possibilities by digital image processing, which is enabled by the computer based image handling, processing and analysis. KW - Industrial radiology KW - Industrial radiography KW - NDT films KW - Computed radiography KW - Digital detector arrays PY - 2018 SN - 978-1-4987-4152-1 SP - Chapter 30, 595 EP - 617 PB - CRC Press CY - Boca Raton, FL, USA AN - OPUS4-44026 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Rabin, Ira ED - Elgvin, T. T1 - The Temple Scroll: Wrapper and fragment. MS 5095/2, MS 5095/4 N2 - The following specification of experimental methods refers to tests performed in 2009–10 on vellum,textile, ink, pottery, leather, and palm-fibre tool, as described in the chapter written by me and Roman Schütz. KW - Dead Sea Scrolls KW - The Temple Scroll PY - 2016 SN - 978-0-5672-8571-3 SN - 978-0-5671-1300-9 VL - 71 SP - 327 EP - 338 PB - Bloomsbury T&T Clark AN - OPUS4-43949 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Rabin, Ira ED - Elgvin, T. T1 - Palm fibre tool from cave 11Q. MS 5095/3 N2 - The Schøyen Collection includes a palm fibre object claimed to have come from Cave 11. According to Kando, it was found by the Bedouin together with the Temple Scroll, the Temple Scroll wrapper and minor fragments from 11QTᵃ (MS 5095/1) in the scroll jar that is still the property of William Kando. KW - Dead Sea Scrolls KW - Qumran archaeology PY - 2016 SN - 978-0-5672-8571-3 SN - 978-0-5671-1300-9 VL - 71 SP - 357 EP - 359 PB - Bloomsbury T&T Clark AN - OPUS4-43951 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Brüning, Gerrit A1 - Hahn, Oliver ED - Nutt-Kofoth, Rüdiger ED - Plachta, Bodo T1 - Goethes Helena-Dichtung in ursprünglicher Gestalt. Zum methodischen Verhältnis von Materialanalyse und Textkritik N2 - Seit 2009 entsteht die historisch-kritische Hybridediton von Goethes „Faust“. Im Januar 2013 ist im Rahmen dieses editorischen Unternehmens die Röntgenfluoreszenzanalyse (RFA) zum Einsatz gekommen, um auf der Grundlage der Zusammensetzung der verwendeten Eisengallustinten entstehungsgeschichtliche Erkenntnisse über das handschriftliche Material zu gewinnen. Im Mittelpunkt stand neben der zeitlichen Einordnung von Handschriften vor allem die Identifikation von unterscheidbaren Bearbeitungsschichten innerhalb der jeweiligen Handschrift. Besonderes Interesse kommt dabei denjenigen Handschriften zu, von denen sicher ist oder angenommen wird, dass Goethe sie über längere Zeit hinweg oder sogar in sehr großen Abständen bearbeitet hat. Die von der traditionellen Philologie in Anschlag gebrachten äußeren und inneren Gründe und die darauf gestützten Hypothesen haben nicht ausgedient. Hypothesen zur Datierung von Handschriften Goethes lassen sich in der Regel gut anhand bestehender materieller Zusammenhänge (wie der Zuordnung des Papiers in Kombination mit der Bestimmung der Schreiberhand) verifizieren. Dagegen ermöglicht materialwissenschaftliche Charakterisierung der Eisengallustinten alleine zunächst noch keine vergleichbar genauen Datierungen. Eine Kombination der beiden Zugänge und Verfahren kann jedoch dort Erkenntnisse zutage fördern, wo die traditionellen philologischen Mittel ausgeschöpft sind. Dies wird exemplarisch innerhalb der Publikation gezeigt werden. KW - Materialanalyse KW - Eisengallustinten KW - Germanistik PY - 2017 DO - https://doi.org/10.1515/editio-2017-0009 SN - 0931-3079 SN - 1865-9446 VL - 31 SP - 145 EP - 172 PB - Walter de Gruyter GmbH CY - Berlin AN - OPUS4-43849 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Lisec, Jan A1 - Jaeger, C. ED - Antonio, C. T1 - Statistical and Multivariate Analysis of MS-Based Plant Metabolomics Data N2 - Raw data from metabolomics experiments are initially subjected to peak identification and signal deconvolution to generate raw data matrices m × n, where m are samples and n are metabolites. We describe here simple statistical procedures on such multivariate data matrices, all provided as functions in the programming environment R, useful to normalize data, detect biomarkers, and perform sample classification. KW - Mass-Spectrometry KW - Multivariate Statistics PY - 2018 SN - 978-1-4939-7819-9 SN - 978-1-4939-7818-2 DO - https://doi.org/10.1007/978-1-4939-7819-9_20 SN - 1064-3745 SN - 1940-6029 VL - 1778 SP - Chapter 20, 285 EP - 296 PB - Springer-Verlag AN - OPUS4-45492 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Resch-Genger, Ute ED - Schäferling, Michael T1 - Luminescent nanoparticles for chemical sensing and imaging N2 - The implementation of fluorescent methods is of outstanding importance in the field of optical chemical sensor Technology and biosciences. Their bioanalytical applications are manifold including fluorescence microscopy, fluorescence in situ hybridization, DNA sequencing, fluorescence-activated cell sorting, immunoassays, analysis of DNA and Protein microarrays, and quantitative PCR, just to name a few examples. Particularly, fluorescence microscopy is a valuable method in the versatile field of biomedical imaging methods which nowadays utilizes different fluorescence Parameters like emission wavelength/Color and lifetime for the discrimination between different targets. Sectional Images are available with confocal microscopes. Tissue, cells or single cellular compartments can be stained and visualized with fluorescent dyes and biomolecules can be selectively labeled with fluorescent dyes to Monitor biomolecular interactions inside cells or at Membrane bound receptors. On the other hand , fluorophores can act as indicator (or "molecular probe") to visualize intrinsically colorless and non-fluorescent ionic and neutral analytes such as pH, Oxygen (pO2), metal ions, anions, hydrogen peroxide or bioactive small organic molecules such as Sugars or nucleotides. Thereby, their photoluminescent properties (fluorescence or phoporescence intensity, exitation and/or Emission wavelength, emission lifetime or anisotropy) respond to the presence of these species in their immediate Environment. In general, the use of luminescent probes has the advantage that they can be delivered directly into the sample, and detected in a contactless remote mode. By now, these probes are often encapsulated in different types of nanoparticles (NPs) made from (biodegradable) organic polymers, biopolymers or inorganic materials like silica or bound to their surface. KW - Fluorescence KW - Upconversion KW - NIR KW - Sensor KW - Nanoparticle KW - Surface chemistry KW - Quantum yield KW - Liftetime KW - Nanocrystal KW - Lanthanide KW - Semiconductor KW - Polymer KW - Silica KW - Imaging KW - Application KW - Dye KW - Quantum dot PY - 2017 SN - 978-3-319-48260-6 SN - 978-3-319-48259-0 DO - https://doi.org/10.1007/978-3-319-48260-6_5 SN - 1573-8086 SP - 71 EP - 109 PB - SPRINGER INTERNATIONAL PUBLISHING AG CY - Cham, Schweiz AN - OPUS4-44011 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Schönhals, Andreas A1 - Frick, B. A1 - Zorn, R. ED - Kremer, Friedrich ED - Loidl, Alois T1 - The scaling of the molecular dynamics of liquid crystals as revealed by broadband dielectric, specific heat, and neutron spectroscopy N2 - A combination of different complementary methods is employed to investigate scaling of the molecular dynamics of two different liquid crystals. Each method is sensitive to different kind of fluctuations and provides therefore a different window to look at the molecular dynamics. In detail, broadband dielectric spectroscopy is combined with specific heat spectroscopy and neutron scattering. As systems the nematic liquid crystal E7 and a discotic liquid crystalline pyrene are considered. First of all it was proven that both systems show all peculiarities which are characteristic for glassy dynamics and the glassy state. Especially for the nematic liquid crystal E7 it could be unambiguously shown by a combination of dielectric and specific heat spectroscopy that the tumbling mode is the underlying motional process responsible for glassy dynamics. Dielectric investigations on the discotic liquid crystalline pyrene reveal that at the phase transition from the plastic crystalline to the hexagonal columnar liquid crystalline phase the molecular dynamics changes from a more strong to fragile temperature dependence of the relaxation rates. Moreover a combination of results obtained by specific heat spectroscopy with structural methods allows an estimation of the length scale relevant for the glass transition. KW - Broadband dielectric spectroscopy KW - Specific heat spectroscopy KW - Rod-like liquid crystals KW - Discotic liquid crystals PY - 2018 UR - https://link.springer.com/content/pdf/10.1007%2F978-3-319-72706-6.pdf SN - 978-3-319-72705-9 SN - 978-3-319-72706-6 DO - https://doi.org/10.1007/978-3-319-72706-6_9 SN - 2190-930X SN - 2190-9318 SP - 279 EP - 306 PB - Springer International publishing AG CY - Cham, Switzerland ET - 1. AN - OPUS4-45624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Golle, U. A1 - Hahn, Oliver A1 - Wintermann, C. ED - Brahms, I. T1 - Rötel und Eisengallustinte als Farbeffekte in der Zeichnung N2 - Eine Vielzahl unterschiedlicher Materialien findet für die farbliche Gestaltung von Zeichnungen Verwendung. Einige Pigmente und Farbstoffe, d.h. Tinten, Stifte oder Kreiden, waren nur für den Gebrauch als Zeichenmittel vorgesehen – andere wiederum finden sich auch in der Tafel- oder Fassmalerei. Ausgehend von schwarzen Zeichenmaterialien soll zunächst eine allgemeine Typologie der Farbmittel entwickelt werden, um den Kosmos dieser Vielfältigkeit zu illustrieren. In einem zweiten Teil werden farbige Elemente am Beispiel von Rötel in Zeichnungen hinterfragt, deren Funktion und Bedeutung sich aus der Betrachtung heraus nicht unbedingt sofort erschließt. So diente die Farbe hier weder der naturgetreuen Nachahmung, noch wurde sie für eine nachträgliche Wertsteigerung eingesetzt. Der dritte Teil dieses Exkurses widmet sich schließlich solchen „farbigen“ Elementen, deren Konnotationen sich aus den Zeichnungen nicht ermitteln lassen und die daher zunächst irritieren. Diese vermeintliche Farbigkeit war aber ursprünglich vielleicht gar nicht intendiert, sondern ist vielmehr auf Alterungs- und Korrosionsprozesse zurückzuführen. KW - Zeichenmaterialien KW - Eisengallustinte KW - Rötel KW - Zerstörungsfreie Prüfung PY - 2020 SN - 978-3-7319-0772-5 SP - 152 EP - 159 PB - Michael Imhof Verlag CY - Petersberg AN - OPUS4-51404 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Hübert, Thomas A1 - Tiebe, Carlo A1 - Banach, Ulrich ED - Rodriguez Mendez, M. T1 - Electronic Noses for the Quality Control of Spices N2 - The chapter describes the application of electronic noses (multigas sensors) for the quality control of spices and spice mixtures. Electronic noses were successfully applied for headspace analysis of spices. It was demonstrated in many investigations that electronic noses can contribute to the characterization of spices and spice mixtures in order to distinguish spices and spice mixtures, differentiate by origin, growth seasons,and processing,indicate adulteration from original, detect mold infestation. Electronic noses can be used as a fast screening method to provide information about the product quality. However, it needs samples and methods for reference, careful training, and complex calibration to consider influencing and disturbing effects as well as the possible limitations of the instrumentation. The correlation to classical chemical analysis methods is always advisable. Machined olfaction methods are capable to support the sensory analysis; however, they cannot yet substitute them. KW - Spice KW - Electronic Nose KW - Multigas sensor KW - Quality control PY - 2016 SN - 978-0-12-800243-8 DO - https://doi.org/10.1016/B978-0-12-800243-8.00012-3 SP - Chapter 12, 115 EP - 124 PB - Academic Press CY - Oxford AN - OPUS4-35443 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Rabin, Ira A1 - Hahn, Oliver ED - Michel, C. ED - Friedrich, M. T1 - Detection of Fakes: The Merits and Limits of Non-Invasive Materials Analysis N2 - This paper addresses the sensitive issue of authenticating unprovenanced manuscripts of high monetary value to certify they are genuine. Over the last decade, the popularity of material studies of manuscripts using non-destructive testing (NDT) has increased enormously. These studies are held in especially high esteem in the case of suspicious writings due to the methodological rigour they are reputed to contribute to debate. We would like to stress that materials analysis alone cannot prove that an object is genuine. Unfortunately, audiences with a humanities background often tend to disregard the technical details and treat any published interpretation of instrumental analysis as an objective finding. Four examples are outlined here to illustrate what questionable contributions the natural sciences can make in describing manuscripts that have actually been forged. KW - Fakes KW - Non-invasive analysis KW - Limitations PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517202 SN - 978-3-11-071422-7 DO - https://doi.org/10.1515/9783110714333 SN - 2365-9696 VL - 20 SP - 281 EP - 290 PB - Walter de Gruyter GmbH CY - Berlin/Boston AN - OPUS4-51720 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Zorn, Sabine A1 - Bosch, S. A1 - Hahn, Oliver ED - Klemm, D. ED - Stolzenburg, A. T1 - Materialtechnologische Untersuchungen an vier Zeichnungen Leonardo da Vincis aus dem Kupferstichkabinett N2 - Das Kupferstichkabinett der Hamburger Kunsthalle besitzt seit seiner Gründung vier Zeichnungen von Leonardo da Vinci (1452–1519). Sie sind Teil eines umfangreichen Legats des Hamburger Kunsthändlers Georg Ernst Harzen, das der Stadt Hamburg für die 1869 eröffnete Kunsthalle als Besitz übereignet wurde. Die Zeichnungen gelten aufgrund ihrer Provenienzen und stilistischen Verankerung im Werk Leonardos als gesichert. Weiterführende materialtechnologische Untersuchungen wurden nun erstmals anlässlich der Ausstellung »Leonardo da Vinci – Die Zeichnungen im Hamburger Kupferstichkabinett« durchgeführt. KW - Zerstörungsfreie Prüfung KW - Zeichnung KW - Leonardo da Vinci PY - 2019 SN - 978-3-938002-56-8 SP - 128 EP - 135 PB - Druckhaus Köthen CY - Köthen AN - OPUS4-49667 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Hahn, Oliver A1 - Golle, U. A1 - Wintermann, C. ED - Knebel, K. ED - Maul, G. ED - Schmuck, T. T1 - Schwarz auf Weiß N2 - In der Sammlung des Naturwissenschaftlichen Kabinetts Johann Wolfgang von Goethes wird ein eher unscheinbares Stück Papier aufbewahrt, welches einen grauschwarzen Aufstrich aufweist. Bei genauerer Betrachtung glaubt man, drei Querstreifen mit rötlicher, weißlicher und bläulicher Farbe innerhalb des grauschwarzen Aufstrichs zu erkennen. Das Papier weist oben die Skizze eines Prismas, im mittleren Bereich am rechten Rand die Beschriftungen „violett/blau“, „weiß“ sowie „gelb/roth“ auf. Interessanterweise ist die Aufschrift „violett/blau“ dem eher rötlichen, die Aufschrift „gelb/roth“ dem eher bläulichen Querstreifen zugeordnet. Die rechte untere Ecke ist mit „Sk“ (Seebeck?) gekennzeichnet. Sowohl die Beschriftungen als auch die Skizze wurden mit einem Graphitstift ausgeführt. Das Papier ist auf eine Pappe mit Papprahmen geklebt und mit schwarzem Papier umwickelt. Es ist unumstritten, dass es sich bei diesem Objekt um das Ergebnis eines naturwissenschaftlichen Experiments handelt, doch was stellt es dar und lässt sich die ursprüngliche Versuchsanordnung aus dem vorliegenden Befund und weiterer, heute zugänglicher naturwissenschaftlichen Untersuchungen rekonstruieren? KW - Zerstörungsfreie Prüfung KW - Farbenlehre KW - Papier KW - Johann Wolfgang von Goethe PY - 2019 SN - 978-3-95498-486-2 SP - 354 EP - 357 PB - Sandstein Verlag CY - Dresden AN - OPUS4-49668 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Telgmann, L. A1 - Lindner, U. A1 - Lingott, J. A1 - Jakubowski, Norbert ED - Prof. Dr. Golloch, Alfred T1 - Analysis and speciation of lanthanoides by ICP-MS N2 - Inductively coupled plasma mass spectrometry (ICP-MS) is based on formation of positively charged atomic ions in a high-frequency inductively coupled Argon plasma at atmospheric pressure. The ions are extracted and transferred from the plasma source into a mass analyzer operated at high vacuum via an interface equipped with a sampling and a skimmer cone. The ions are separated in the mass analyzer according to their charge to mass ratio. The ions are converted at a conversion dynode and are detected by use of a secondary electron multiplier or a Faraday cup. From an analytical point of view, ICP-MS is a well-established method for multi-elemental analysis in particular for elements at trace- and ultra-trace levels. Furthermore, methods based on ICP-MS offer simple quantification concepts, for which usually (liquid) standards are applied, low matrix effects compared to other conventional analytical techniques, and relative limits of detection (LODs) in the low pg g−1 range and absolute LODs down to the attomol range. For these applications, ICP-MS excels by a high sensitivity which is independent of the molecular structure and a wide linear dynamic range. It has found acceptance in various application areas and during the last decade ICP-MS is also more and more applied for detection of rare earth elements particularly in the life sciences. Due to the fact that all molecules introduced into the high temperature of the plasma in the ion source were completely dissociated and broken down into atoms, which are subsequently ionized, all elemental species information is completely lost. However, if the different species are separated before they enter the plasma by using adequate fractionation or separation techniques, then ICP-MS can be used as a very sensitive element-specific detector. We will discuss this feature of ICP-MS in this chapter in more detail at hand of the speciation of gadolinium-containing contrast agents. KW - Analysis of lanthanoides KW - ICP-MS KW - Speciation of Gd-containing MRI contrast agents PY - 2017 SN - 978-3-11-036523-8 SP - Chapter 5, 124 EP - 144 PB - De Gruyter AN - OPUS4-40238 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Müller, L. A1 - Traub, Heike A1 - Jakubowski, Norbert ED - Prof. Dr. Golloch, Alfred T1 - Novel applications of lanthanoides as analytical or diagnostic tools in the life sciences by ICP-MS-based techniques N2 - Inductively coupled plasma mass spectrometry (ICP-MS) is a well-established analytical method for multi-elemental analysis in particular for elements at trace and ultra-trace levels. It has found acceptance in various application areas during the last decade. ICP-MS is also more and more applied for detection in the life sciences. For these applications, ICP-MS excels by a high sensitivity, which is independent of the molecular structure of the analyte, a wide linear dynamic range and by excellent multi-element capabilities. Furthermore, methods based on ICP-MS offer simple quantification concepts, for which usually (liquid) standards are applied, low matrix effects compared to other conventional bioanalytical techniques, and relative limits of detection (LODs) in the low pg g−1 range and absolute LODs down to the attomol range. In this chapter, we focus on new applications where the multi-element capability of ICP-MS is used for detection of lanthanoides or rare earth elements, which are applied as elemental stains or tags of biomolecules and in particular of antibodies. KW - ICP-MS KW - Life sciences KW - Mass cytometry KW - Laser ablation (LA)-ICP-MS KW - Bioimaging PY - 2017 SN - 978-3-11-036523-8 SP - Chapter 11, 301 EP - 320 PB - De Gruyter AN - OPUS4-40244 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -