TY - JOUR A1 - Usmani, Shirin A1 - Stephan, Ina A1 - Huebert, Thomas A1 - Kemnitz, E. T1 - Nano metal fluorides for wood protection against fungi JF - ACS Applied Nano Materials N2 - Wood treated with nano metal fluorides is found to resist fungal decay. Sol−gel synthesis was used to synthesize MgF2 and CaF2 nanoparticles. Electron microscopy images confirmed the localization of MgF2 and CaF2 nanoparticles in wood. Efficacy of nano metal fluoride-treated wood was tested against brown-rot fungi Coniophora puteana and Rhodonia placenta. Untreated wood specimens had higher mass losses (∼30%) compared to treated specimens, which had average mass loss of 2% against C. puteana and 14% against R. placenta, respectively. Nano metal fluorides provide a viable alternative to current wood preservatives. KW - Brown-rot fungi KW - Coniophora puteana KW - Fluoride nanoparticles KW - Fluorolytic sol−gel KW - Rhodonia placenta KW - SEM wood characterization KW - Wood protection PY - 2018 DO - https://doi.org/10.1021/acsanm.8b00144 SN - 2574-0970 VL - 2018 SP - 1 EP - 6 PB - American Chemical Society (ACS) CY - Washington DC, US AN - OPUS4-44730 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Bartholmai, Matthias A1 - Hofmann, Michael T1 - VDI/VDE 3518 Technische Richtlinie für Multigassensoren N2 - Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt. T2 - NetMon International training course - Low-cost Environmental Monitoring CY - BAM, Berlin, Germany DA - 09.04.2019 KW - Multigassensoren KW - Prüfung KW - Richtlinie PY - 2018 AN - OPUS4-47885 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias A1 - Banach, Ulrich A1 - Gawlitza, Kornelia A1 - Hübert, Thomas T1 - Development of a gas standard generator N2 - Pollution through emission of toxic gases is an increasing problem for the environment. It affects similarly agricultural, industrial and urban areas. In future, environmental emissions in ambient air must be monitored at even lower concentrations as nowadays. One environmental relevant compound is ammonia and its conversion product ammonium that have strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the range below 1000 nmol·mol 1 and thus there is a need for reliable traceable ammonia gas standards and in addition in situ analytical procedures for monitoring (in ambient air to avoid that thresholds are exceeded). Therefore, the use of reference materials is necessary for development accompanying test or for calibration, e. g. of structure-integrated sensors and mobile multi-gas sensors. The developed gas standard generator produces gas mixtures that comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range. The method is based on the permeation of ammonia through a membrane at constant temperature and pressure. The resulting ammonia penetrant gas flow is then mixed with a carrier gas flow to generate a gas standard flow of known concentration. The dynamic rage is enlarged by using a two dilution steps. Depending on the permeation rate, generable molar fractions are possible in the range nmol·mol-1 to a few µmol·mol-1. We present the design of an ammonia gas standard generator and first results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. The relative uncertainty of the generated ammonia gas standard is smaller than 4 % (k = 2). T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Permeation KW - Gas standard generator PY - 2018 AN - OPUS4-44089 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Detjens, Marc A1 - Fechner, A. A1 - Sielemann, S. A1 - Lorek, A. A1 - Wernecke, R. A1 - Stoltenberg, H. T1 - Development of a device for staged determination of water activity and moisture content T2 - Proceedings N2 - Moisture content and water activity are important parameters for quality characterization of products like bulk materials, powders, granules. Thus, an exact determination is necessarily required in a wide range of industrial applications. Moisture of materials is the content of non-chemically bound water in a solid or liquid. Water activity (aW) is a characteristic/parameter of the non-chemically bound ("free") water in materials and is measured as humidity over a solid/liquid surface at constant temperature (equilibrium moisture content). It is an important parameter to characterize the quality of e. g. pharmaceutical and food products. In our contribution, we present the developed MOISHUM device for staged determination of water activity and moisture content of liquid and solid materials. T2 - Eurosensors 2018 CY - Graz, Austria DA - 09.09.2018 KW - Water activity KW - Moisture KW - Coulometric humidity sensor KW - MOISHUM PY - 2018 SN - 2504-3900 SP - 7253, 1 EP - 4 PB - MDPI AN - OPUS4-46210 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tiebe, Carlo A1 - Detjens, Marc A1 - Banach, Ulrich A1 - Hübert, Thomas T1 - Measurement uncertainty of coulometric trace humidity sensors JF - tm - Technisches Messen N2 - Especially trace amounts of water vapour in gases can be reliably determined by coulometric trace humidity sensors. The principle of these sensors is based on water vapour absorption in a hygroscopic layer and its subsequent electrolytic decomposition. The calibration of sensors was performed in the humidity range, expressed as frost point temperature, from −30°C to −80°C . This range is equivalent to volume fractions smaller than 376 µL·L−1. Generated humidity was measured with coulometric sensors and a chilled dew point hygrometer that was used as reference. An empirical non-linear function was found between sensor signal and measured reference humidity. This function consists of two parameters with a measurement uncertainty. Both calibration parameters were checked by means of one-way analysis of variance. It showed that gas specific function can be used for humidity measurement in nitrogen, hydrogen, dinitrogen monoxide, compressed and synthetic air. It is possible to determine trace humidity in all tested gases with an expanded uncertainty less than 2.1 K (coverage factor k=2 ) regarding frost point temperature. KW - Trace humidity KW - Coulometric sensor KW - Measurement uncertainty KW - ANOVA PY - 2018 DO - https://doi.org/10.1515/teme-2018-0031 SN - 0171-8096 VL - 85 IS - 12 SP - 746 EP - 753 PB - De Gruyter CY - Oldenbourg AN - OPUS4-45959 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Detjens, Marc A1 - Banach, Ulrich T1 - Messunsicherheiten von Feuchtesensoren N2 - Inhalt dieses Seminarbeitrags sind Hygrometer und Kenngrößen der Hygrometrie, Anforderungen an ein Prüflabor sowie die Bestimmung der Messunsicherheit bei der Prüfung von Feuchtesensoren wie auch Prüfung auf signifikante Abweichungen. T2 - 308. PTB-Seminar Berechnung der Messunsicherheit – Empfehlungen für die Praxis CY - Berlin, Germany DA - 15.03.2018 KW - Messunsicherheit KW - Feuchtesensor KW - Prüflabor PY - 2018 UR - https://www.ptb.de/cms/fileadmin/internet/fachabteilungen/abteilung_8/8.4_mathematische_modellierung/308._PTB_Seminar/Vortraege/4PraxisII/Messunsicherheiten_von_Feuchtesensoren.pdf AN - OPUS4-44546 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Bartholmai, Matthias A1 - Gawlitza, Kornelia T1 - Two tasks in environmental monitoring - calibration and characterization of gas sensors and remote sensing with multicopter platforms - Part 2 N2 - Emissions of ammonia into the environment are mainly caused by agriculture, but also by combustion processes in waste and by road traffic. Even at low concentrations, this substance is not only an odour nuisance, but also a substance with ecological and climatic relevance. Therefore, BAM tested commercial electrochemical, and metal oxide based sensors, which have limited suitability for measuring in the environmental molar fraction range. Alternatively, own developments for the detection of ammonia in the trace range were implemented, wherein the analyte is measured by changing the fluorescence of a BODIPY dye at 550 nm by means of a portable fluorescence sensor directly from the gas phase. For the calibration of ammonia sensors and measuring instruments, a stationary system based on the mixture of certified test gases from pressure cylinders with calibrated mass flow controllers is available. A test gas generator was developed for on-site calibration and testing of sensors and measuring devices. The generation of ammonia-containing gases in the environmental relevant range of levels below 1000 nmol/mol is carried out by the permeation method according to ISO 6145-10. For the traceability of ammonia, standards are provided and further developed by the National Metrological Institutes and designated institutes. Metrological standards are based on SI units and are a basis for traceability of sensors or gas analysers. T2 - Aarhus University, Department of Environmental Science, External seminar with Matthias Bartholmai and Carlo Tiebe CY - Roskilde, Denmark DA - 29.08.2018 KW - Environmental monitoring KW - Test gas generation KW - Fluorescence sensor KW - Ammonia PY - 2018 AN - OPUS4-45842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Banach, Ulrich A1 - Hübert, Thomas T1 - VDI/VDE-Richtlinie für Multigassensoren N2 - Technische Richtlinien enthalten Empfehlungen sowie Anforderungen zum Stand der Technik zur Aufstellung von Bewertungskriterien und Behandlung wissenschaftlich-technischer Fragen. Sie fördern den Erfahrungsaustausch und Technologietransfer zwischen Entwicklern und Anwendern. In unserem Beitrag stellen wir die Richtlinie VDI/VDE 3518 vor. Diese Richtlinienreihe definiert Begriffe, beschreibt den Aufbau und klassifiziert Multigassensoren (Blatt 1), befasst sich mit den Anforderungen für das Unterscheiden, Erkennen und mengenmäßige Bestimmen von Gemischen gasförmiger Stoffe und die Prüfung von Multigassensoren (Blatt 2) und gibt Anleitung für geruchsbezogene Messungen mit „Elektronischen Nasen“ (Blatt 3). Multigassensoren können als elektronische Nasen in Anlehnung an den biologischen Geruchssinn zur Wahrnehmung und Charakterisierung von Gerüchen eingesetzt werden. Die Spezifik von Multigassensoren besteht darin, dass durch die Wahl und Betriebsweise der Sensoren eine Vielzahl von geeigneten Messsignalen erzeugt werden, aus denen mit mathematischen Verfahren die für die Anwendung gewünschten Informationen extrahiert werden. Dazu ist ein Training der Messeinrichtung mit Proben bekannter Eigenschaften notwendig. Diese Richtlinie soll Herstellern, Anbietern und Nutzern als ein Leitfaden Informationen und Erläuterungen für die korrekte und sichere Arbeit mit Multigassensoren liefern. Sie soll Prüflaboratorien und Anwendern helfen, bei der Beurteilung von Qualitätsmerkmalen einheitlich vorzugehen und dafür gemeinsame Randbedingungen anzugeben T2 - 7. Anwendertreffen Ionenmobilitätsspektrometrie CY - Reutlingen, Germany DA - 06.03.2018 KW - Elektronische Nase KW - Multigassensorik KW - Richtlinie PY - 2018 AN - OPUS4-44452 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Detjens, Marc A1 - Fechner, A. A1 - Sielemann, S. A1 - Lorek, A. A1 - Wernecke, R. A1 - Stoltenberg, H. T1 - Development of a device for staged determination of water activity and moisture content N2 - Moisture content and water activity are important parameters of product characterization; thus, an exact determination is necessarily required in a wide range of industrial applications. Moisture content of materials is the content of non-chemically bound water in a solid or liquid. Water activity (aW) is a characteristic/parameter of the non-chemically bound ("free") water in materials and is measured as humidity over a solid/liquid surface at constant temperature (equilibrium moisture content). It is an important parameter to characterize the quality of pharmaceutical and food products. In our contribution, we present a developed device for staged determination of water activity and moisture content of liquid and solid materials. T2 - Eurosensors 2018 CY - Graz, Austria DA - 09.09.2018 KW - Water activity KW - Moisture content KW - Measuring cell KW - Sorption isotherm PY - 2018 AN - OPUS4-45943 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Banach, Ulrich A1 - Hübert, Thomas A1 - Bartholmai, Matthias A1 - Noske, Reinhard A1 - Gawlitza, Kornelia A1 - Rurack, Knut T1 - Ammoniakbestimmung mit einem portablen Fluoreszenzsensor N2 - Ammoniakemissionen in die Umwelt erfolgen insbesondere durch die Landwirtschaft (93,6 %), aber auch durch Verbrennungsprozesse in der die Abfallwirtschaft (2,3 %) und den Straßenverkehr (1,8 %). Dieser Stoff ist selbst in geringen Konzentrationen nicht nur eine Geruchsbelästigung, sondern auch eine Substanz mit ökologischer und klimatischer Relevanz. Die Bestimmung von Ammoniak in relevanten Konzentrationen von kleiner 25 μg m-3 erfolgt im Allgemeinen über NH4+ als Analyten, spektralfotometrisch oder mit der Ionenchromatographie nach Überführung in die flüssige Phase. Wegen der niedrigen Konzentrationen an Ammoniak in der Außenluft wird meist eine gesammelte Probe verwendet oder die Bestimmung erfolgt nach einer aktiven, anreichernden Probenahme. Die eigenen Arbeiten sollen dazu beitragen, die Ammoniak-Bestimmung in der Außenluft präziser, sowie schneller und kostengünstiger zu machen. Die BAM prüfte daher kommerzielle elektrochemische und Metalloxid-basierte Sensoren, die für diesen Konzentrationsbereich aber nur bedingt geeignet sind. Deshalb wurden alternativ eigene Entwicklungen zum Nachweis von Ammoniak im Spurenbereich aufgenommen, wobei der Analyt über die Änderung der Fluoreszenz eines BODIPY-Farbstoffs bei 550 nm mittels eines portablen Fluoreszenz-Sensors direkt aus der Gasphase gemessen wird. Zur Kalibrierung von Ammoniak-Sensoren und -Messgeräten steht ein stationäres System basierend auf der Mischung von zertifizierten Prüfgasen aus Druckflaschen mit kalibrierten Massendurchfluss-regler (MFC) zur Verfügung. Darüber hinaus erfolgt eine chemische Analyse der verwendeten Gasgemische mittels eines Massenspektrometers. Für die Kalibrierung und Prüfung von Sensoren und Messgeräten vor Ort wurde ein mobiles Prüfsystem entwickelt. Die Generierung von Ammoniak-haltigen Gasen im Spurenbereich von 0,5 nmol/mol bis 500 nmol/mol erfolgt durch das Permeationsverfahren nach ISO 6145-10. Für die Realisierung der Rückführbarkeit der Ammoniakbestimmung werden von den Nationalen Metrologischen Instituten sowie designierten Instituten Standards bereitgestellt und auch weiterentwickelt. Die primären metrologischen Standards beruhen auf SI-Einheiten und sind die Basis für eine Rückführbarkeit der Sensoren bzw. Analysengeräte. T2 - 5. Fachsymposium „Intelligente Sensorik/Analytik und sichere Sensornetze: Innovative Technologien und neue Anwendungsfelder“ CY - Karlsruhe, Germany DA - 14.11.2018 KW - Ammoniak KW - Sensor KW - Multigassensorik PY - 2018 AN - OPUS4-46926 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schütze, A. A1 - Tiebe, Carlo T1 - Gas sensor characterization and calibration N2 - This seminar contribution contains the topics: 3S - sensitivity, selectivity and stability; sensor drift, aging and poisoning; influence of ambient conditions; gas mixing systems for sensor characterization and on-site field (re)calibration. T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Gas sensor KW - Gas mixing systems KW - Sensor characterization PY - 2018 AN - OPUS4-44088 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Schukar, Vivien A1 - Bartholmai, Matthias A1 - Beck, Uwe T1 - Abschlussbericht zum DFG-Projekt „FAMOS²“ FAser-basierter Magneto-Optischer SchichtSensor N2 - Der Mangel an Anwendungsrichtlinien und Validierungsverfahren für struktur-eingebettete faseroptische Dehnungssensoren, insbesondere auf Faser-Bragg-Gitter (FBG)-Basis, führte bislang dazu, dass diese Sensoren trotz ihrer hervorragenden Eigenschaften im Bereich der kommerziellen Material- und Strukturüberwachung nur in geringem Umfange eingesetzt wurden. Fragen zur Degradation der Sensoren unter Beanspruchung, Alterung durch klimatische Einflüsse und Enthaftung infolge Belastung der Struktur konnten bisher nur theoretisch simuliert oder anhand exemplarischer Proben für einzelne einflussnehmende Parameter im Labor untersucht werden. Die Erfassung des Sensorverhaltens im Bauteil unter komplexen Umwelteinflüssen während des Bauteilbetriebes, um damit eine Aussage zur Zuverlässigkeit der Sensormessdaten zu gewinnen, war bisher nicht möglich. Im Forschungsprojekt FAMOS² wurde deshalb von 2014 bis 2018 die Realisierung eines Autodiagnoseverfahrens für faseroptische Dehnungssensoren erarbeitet, um die Funktionszuverlässigkeit und Langzeitstabilität der Sensoren während des Bauteilbetriebes innerhalb einer Bauteilstruktur bewerten zu können. Im Rahmen des Forschungsprojektes wurde gezeigt, dass ein FBG-Sensor mit einer speziell angepassten magnetostriktiven Schicht magnetisch so angeregt werden kann, dass mit einer zugeschnittenen Messmethodik zu jedem Zeitpunkt eine Bewertung der Sensorzuverlässigkeit unter Betriebsbedingungen möglich ist. Die auf den Sensor aufgebrachte magnetostriktive Schicht erzeugt bei Anregung mit einem passenden Magnetfeld eine gepulste, synthetische Dehnung. Diese Dehnung steht in einem definierten Verhältnis zum anregenden Magnetfeld und wird optisch über die Verschiebung der Bragg-Wellenlänge ausgelesen. Die Konstanz dieses Verhältnisses stellt dann ein Maß für die korrekte Funktionsfähigkeit des Sensors dar. Das Beschichtungs-verfahren, das magnetische Anregungs- und optische Ausleseverfahren, wie auch die Validierung des Sensors unter Berücksichtigung faseroptischer Effekte wurden während des Projekts konzeptionell entwickelt, aufgebaut und charakterisiert. Qualitativ kann mit diesem Verfahren zunächst eine Gut-/Schlecht-Beurteilung des Sensors vorgenommen werden. Perspektivisch bietet das Verfahren jedoch auch die Möglichkeit, verschiedene Versagensmechanismen bestimmen und klassifizieren zu können. Es zeichnete sich schon während des Projektverlaufs ab, dass sich aus den erzielten Ergebnissen über das Autodiagnoseverfahren hinaus weitere Anwendungsmöglichkeiten für den Einsatz des kombinierten magnetostriktiv-faseroptischen Sensorprinzips, beispielsweise als reiner Magnetfeldsensor, ergeben. Nach Abschluss dieses Forschungsprojekts besteht nun die Möglichkeit, den Funktionszustand faseroptischer Dehnungssensoren jederzeit unabhängig von Alter, Belastung oder Kenntnis eines Referenzzustands zu einem bestimmten Zeitpunkt bestimmen zu können. Aufbauend auf diesen Ergebnissen können weiterführende Forschungen die Messmethodik vertiefend charakterisieren und weitere Anwendungsfälle erschließen. KW - Faser-Bragg-Gitter (FBG) KW - Sensorvalidierung KW - Magnetostriktive Beschichtung KW - Structural Health Monitoring (SHM) PY - 2018 N1 - Das Dokument unterliegt der Vertraulichkeit und kann nicht zugänglich gemacht werden - Projektlaufzeit: 01.04.2014 - 31.07.2018 The document is subject to confidentiality restrictions and cannot be made accessible - project runtime: 01.04.2014 - 31.07.2018 SP - 1 EP - 28 AN - OPUS4-50418 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Tiebe, Carlo A1 - Bartholmai, Matthias A1 - Hüllmann, Dino A1 - Krentel, Daniel A1 - Kluge, Martin A1 - Kohlhoff, Harald A1 - Lilienthal, A.J. T1 - Airborne Remote Gas Sensing and Mapping N2 - Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions. T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Localization of gas sources KW - Mobile Robot Olfaction KW - Tomographic reconstruction of gas plumes KW - Tunable Diode Laser Absorption Spectroscopy (TDLAS) KW - UAV-REGAS PY - 2018 AN - OPUS4-44085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Krentel, Daniel A1 - Kluge, Martin A1 - Kohlhoff, Harald A1 - Lilienthal, A. J. T1 - Gas Tomography Up In The Air! T2 - Proceedings of the IEEE Sensors 2018 N2 - In this paper, we present an autonomous aerial robot to reconstruct tomographic 2D slices of gas plumes in outdoor environments. Our platform, the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS) combines a lightweight Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile octocopter. The TDLAS sensor provides integral gas concentration measurements but no information regarding the distance traveled by the laser diode's beam or the distribution of the gas along the optical path. We complemented the set-up with a laser rangefinder and apply principles of Computed Tomography (CT) to create a model of the spatial gas distribution from these integral concentration measurements. To allow for a rudimentary ground truth evaluation of the applied gas tomography algorithm, we set up a unique outdoor test environment based on two 3D ultrasonic anemometers and a distributed array of 10 infrared gas transmitters. We present first results showing the 2D plume reconstruction capabilities of the system under realistic conditions. T2 - IEEE Sensors 2018 CY - New Delhi, India DA - 28.10.2018 KW - Aerial robot KW - TDLAS KW - Gas tomography KW - Plume PY - 2018 SN - 978-1-5386-4707-3 SP - 396 EP - 398 PB - IEEE AN - OPUS4-46477 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Bartholmai, Matthias ED - Pastramă, D. Ş ED - Constantinescu, D. M. T1 - Concept of a gas-sensitive nano aerial robot swarm for indoor air quality monitoring T2 - 35th Danubia - Adria Symposium on Advances in Experimental Mechanics - Extended abstracts N2 - In industrial environments, airborne by-products such as dust and (toxic) gases, constitute a major risk for the worker’s health. Major changes in automated processes in the industry lead to an increasing demand for solutions in air quality management. Thus, occupational health experts are highly interested in precise dust and gas distribution models for working environments. For practical and economic reasons, high-quality, costly measurements are often available for short time-intervals only. Therefore, current monitoring procedures are carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only. Real-time knowledge of contaminant distributions inside the working environment would also provide means for better and more economic control of air impurities. For example, the possibility to regulate the workspace’s ventilation exhaust locations can reduce the concentration of airborne contaminants by 50%. To improve the occupational health and safety of (industrial) workplaces, this work aims for developing a swarm of gas-sensitive aerial nano robots for monitoring indoor air quality and for localizing potential emission sources. T2 - 35th Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Sinaia, Romania DA - 25.09.2018 KW - Mobile Robot Olfaction KW - Swarm KW - Nano aerial robot KW - Gas sensing PY - 2018 SN - 978-606-23-0874-2 SP - 139 EP - 140 PB - PRINTECH CY - Bukarest AN - OPUS4-46137 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias A1 - Hüllmann, Dino T1 - Concept of a gas-sensitive nano aerial robot swarm for indoor air quality monitoring N2 - In industrial environments, airborne by-products such as dust and (toxic) gases, constitute a major risk for the worker’s health. Major changes in automated processes in the industry lead to an increasing demand for solutions in air quality management. Thus, occupational health experts are highly interested in precise dust and gas distribution models for working environments. For practical and economic reasons, high-quality, costly measurements are often available for short time-intervals only. Therefore, current monitoring procedures are carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only. Real-time knowledge of contaminant distributions inside the working environment would also provide means for better and more economic control of air impurities. For example, the possibility to regulate the workspace’s ventilation exhaust locations can reduce the concentration of airborne contaminants by 50%. To improve the occupational health and safety of (industrial) workplaces, this work aims for developing a swarm of gas-sensitive aerial nano robots for monitoring indoor air quality and for localizing potential emission sources. T2 - Tag der offenen Tür auf dem Testgelände der BAM (BAM TTS) CY - Baruth/Mark - OT Horstwalde, Germany DA - 29.09.2018 KW - Mobile Robot Olfaction KW - Swarm KW - Nano aerial robot KW - Gas sensing PY - 2018 AN - OPUS4-46147 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias A1 - Hüllmann, Dino A1 - Krentel, Daniel A1 - Kluge, Martin A1 - Kohlhoff, Harald A1 - Lilienthal, A. J. T1 - Airborne Remote Gas Sensing and Mapping N2 - Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of These kind of leaks, we developed a novel robotic platform for aerial remote gas sensing - the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS). T2 - Tag der offenen Tür auf dem Testgelände der BAM (BAM TTS) CY - Baruth/Mark - OT Horstwalde, Germany DA - 29.09.2018 KW - Localization of gas sources KW - Mobile Robot Olfaction KW - Tomographic reconstruction of gas plumes KW - Tunable Diode Laser Absorption Spectroscopy (TDLAS) KW - UAV-REGAS PY - 2018 AN - OPUS4-46152 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Kohlhoff, Harald A1 - Bartholmai, Matthias A1 - Bennetts, V.H. A1 - Lilienthal, A.J. T1 - Mobile robot olfaction with flying platforms N2 - This presentation gives an introduction to the gas-sensitive aerial robots developed at BAM, including various application examples in the field of mobile robot olfaction: gas source localization and gas distribution mapping T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Localization of gas sources KW - Mobile Robot Olfaction KW - Tomographic reconstruction of gas plumes KW - Tunable Diode Laser Absorption Spectroscopy (TDLAS) KW - UAV-REGAS PY - 2018 AN - OPUS4-44086 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Krentel, Daniel A1 - Kluge, Martin A1 - Kohlhoff, Harald A1 - Lilienthal, A. J. T1 - Gas Tomography Up In The Air! N2 - In this paper, we present an autonomous aerial robot to reconstruct tomographic 2D slices of gas plumes in outdoor environments. Our platform, the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS) combines a lightweight Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile octocopter. The TDLAS sensor provides integral gas concentration measurements but no information regarding the distance traveled by the laser diode's beam or the distribution of the gas along the optical path. We complemented the set-up with a laser rangefinder and apply principles of Computed Tomography (CT) to create a model of the spatial gas distribution from these integral concentration measurements. To allow for a rudimentary ground truth evaluation of the applied gas tomography algorithm, we set up a unique outdoor test environment based on two 3D ultrasonic anemometers and a distributed array of 10 infrared gas transmitters. We present first results showing the 2D plume reconstruction capabilities of the system under realistic conditions. T2 - IEEE Sensors 2018 CY - New Delhi, India DA - 28.10.2018 KW - Aerial robot KW - TDLAS KW - Gas tomography KW - Plume PY - 2018 AN - OPUS4-46478 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Hüllmann, Dino A1 - Bartholmai, Matthias T1 - Concept of a gas-sensitive nano aerial robot swarm for indoor air quality monitoring N2 - In industrial environments, airborne by-products such as dust and (toxic) gases, constitute a major risk for the worker’s health. Major changes in automated processes in the industry lead to an increasing demand for solutions in air quality management. Thus, occupational health experts are highly interested in precise dust and gas distribution models for working environments. For practical and economic reasons, high-quality, costly measurements are often available for short time-intervals only. Therefore, current monitoring procedures are carried out sparsely, both in time and space, i.e., measurement data are collected in single day campaigns at selected locations only. Real-time knowledge of contaminant distributions inside the working environment would also provide means for better and more economic control of air impurities. For example, the possibility to regulate the workspace’s ventilation exhaust locations can reduce the concentration of airborne contaminants by 50%. To improve the occupational health and safety of (industrial) workplaces, this work aims for developing a swarm of gas-sensitive aerial nano robots for monitoring indoor air quality and for localizing potential emission sources. T2 - 35th Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Sinaia, Romania DA - 25.09.2018 KW - Mobile Robot Olfaction KW - Swarm KW - Nano aerial robot KW - Gas sensing PY - 2018 AN - OPUS4-46140 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Moldenhauer, Laura A1 - Helmerich, Rosemarie A1 - Köppe, E. A1 - Wittmann, H.-J. T1 - Experimental modeling approach for determining the moisture damping exponent of a bluetooth low energy signal in moist building material JF - MaterialsToday: Proceedings N2 - The presented development of a damping model is a research component of an experimental feasibility study about moisture in building materials measured with Bluetooth® Low Energy (BLE) signals. This study may be part of a structural health- and long-term monitoring aiming at early damage detection in the built infrastructure and is increasingly focusing on wireless sensor network technology. It is investigated, how the Received Signal Strength Indicator (RSSI) of a BLE signal, transmitted from the BLE-module embedded in building materials with changing moisture content is damped. The aim of the modelling is the derivation of a damping equation for the formal model to determine the moisture damping exponent to finding a correlation. T2 - 34th Danubia Adria Symposium on Advances in Experimental Mechanics CY - Trieste, Italy DA - 19.09.2017 KW - BLE Bluetooth low energy KW - Sensor network KW - RSSI Received Signal Strength Indicator KW - Structural Health Monitoring KW - Moisture measurements PY - 2018 DO - https://doi.org/10.1016/j.matpr.2018.08.124 SN - 2214-7853 VL - 5 IS - Issue 13, Part 2 SP - 26469 EP - 26792 PB - Elsevier Ltd. CY - Radarweg 29, 1043 NX Amsterdam, The Netherlands AN - OPUS4-47171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mansurova, Maria A1 - Bell, Jérémy A1 - Gotor, Raul A1 - Johann, Sergei A1 - Neumann, Patrick P. A1 - Kohlhoff, Harald A1 - Rurack, Knut T1 - Embedded Fluorescence-Based Optical System for the Detection of Total Petroleum Hydrocarbons in Water and Soil N2 - Contamination of natural bodies of water with oil and lubricants (or generally, hydrocarbon derivatives such as petrol, fuel and others) is a commonly found phenomenon around the world due to the extensive production, transfer and use of fossil fuels. In this work, we develop a simple system for the on-field detection of total petroleum hydrocarbons (TPH) in water and soil. The test is based on fluorescence emission of a 4-dimethylamino-4′-nitrostilbene derivative (4-DNS-OH). This fluorescent molecular rotor is embedded in a hydrophobic polymeric matrix (PVDF), avoiding interactions with water and providing a robust support for use in test-strip fashion. For the fluorescence detection a portable sensor device was developed, featuring two excitation LEDs, a micro-spectrometer and Bluetooth control. A limit of detection of at least 6 ppm of TPH in water was demonstrated. T2 - Europtrode 2018 CY - Naples, Italy DA - 25.03.2018 KW - Water KW - Fluorescence KW - Spectrocube KW - Rapid test KW - Oil PY - 2018 AN - OPUS4-45605 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Manolov, Manol A1 - Subaric-Leitis, Andreas A1 - Bartholmai, Matthias T1 - Bestimmung der Maschinennachgiebigkeit beim Einsatz sphärischer Indenter in der Instrumentierten Eindringprüfung T2 - ITG-Fachbericht 281 Sensoren und Messsysteme 2018 N2 - Es wird ein vereinfachtes Verfahren für die Bestimmung und Implementierung der Maschinennachgiebigkeit bei der Verwendung eines sphärischen Indenters dargestellt. Die Maschinennachgiebigkeit wird bei deutlicher Kraftabhängigkeit als Funktion der Kraft in die Auswertung implementiert. Als sensitiver Kennwert dient der aus der instrumentierten Eindringprüfung an Härtevergleichsplatten ermittelte Eindringmodul. T2 - Sensoren und Messsysteme CY - Nürnberg, Germany DA - 26.06.2018 KW - Maschinennachgiebigkeit KW - Instrumentierte Eindringprüfung KW - Sphärische Indenter KW - Vereinfachtes Verfahren KW - Kraftabhängige Funktion KW - Härtevergleichsplatten KW - Eindringmodul PY - 2018 SN - 978-3-8007-4683-5 SN - 0932-6022 VL - 19. ITG/GMA-Fachtagung SP - 565 EP - 569 PB - VDE Verlag GmbH CY - Berlin AN - OPUS4-45394 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Manolov, Manol A1 - Subaric-Leitis, Andreas A1 - Bartholmai, Matthias T1 - Bestimmung der Maschinennachgiebigkeit beim Einsatz sphärischer Indenter in der Instrumentierten Eindringprüfung N2 - Der Einfluss der Maschinennachgiebigkeit einschließlich der elastischen Verformung des Indenters ist bei der Bestimmung der entsprechenden Werkstoffcharakteristiken insbesondere beim Einsatz von sphärischen Indentern unter höheren Prüfkräften von Bedeutung. Mit zunehmender Prüfkraft wird die Maschinennachgiebigkeit kraftabhängig und kann im idealen Fall als Funktion von Prüfkraft und gemessener Eindringtiefe für vorgegebene Indenterradien dargestellt werden. Angegeben ist ein vereinfachtes Verfahren zur Bestimmung der Maschinennachgiebigkeit. T2 - Sensoren und Messsysteme CY - Nürnberg, Germany DA - 26.06.2018 KW - Maschinennachgiebigkeit KW - Instrumentierte Eindringprüfung KW - Sphärische Indenter KW - Vereinfachtes Verfahren KW - Kraftabhängige Funktion KW - Härtevergleichsplatten KW - Eindringmodul PY - 2018 AN - OPUS4-45390 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Johann, Sergej A1 - Mansurova, Maria A1 - Kohlhoff, Harald A1 - Gkertsos, Aris A1 - Neumann, Patrick P. A1 - Bell, Jérémy A1 - Bartholmai, Matthias T1 - Wireless Mobile Sensor Device for in-situ Measurements with Multiple Fluorescent Sensors T2 - Proceedings of the IEEE Sensors 2018 N2 - This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniatur-ized spectrometer for low light analysis, e.g. fluorescent sensors. Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily imple-mented by adapting the optics and the software (database, data processing and calibration plots, etc.) T2 - IEEE Sensors 2018 CY - New Delhi, India DA - 28.10.2018 KW - Wireless mobile sensor device KW - Fluorescent sensor KW - Embedded system KW - Water quality KW - Oil PY - 2018 SN - 978-1-5386-4707-3 SP - 1067 EP - 1070 PB - IEEE CY - New Delhi, India AN - OPUS4-46556 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Johann, Sergej A1 - Mansurova, Maria A1 - Kohlhoff, Harald A1 - Gkertsos, Aris A1 - Neumann, Patrick P. A1 - Bell, Jérémy A1 - Bartholmai, Matthias T1 - Wireless Mobile Sensor Device for in-situ Measurements with Multiple Fluorescent Sensors N2 - This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniaturized spectrometer for low light analysis, e.g. fluorescent sensors. Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily implemented by adapting the optics and the software (database, data processing and calibration plots, etc.). T2 - IEEE Sensors 2018 CY - New Delhi, India DA - 28.10.2018 KW - Wireless mobile sensor device KW - Fluorescent sensor KW - Embedded system KW - Water quality KW - Oil PY - 2018 AN - OPUS4-46554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hüllmann, Dino A1 - Paul, Niels A1 - Kohlhoff, Harald A1 - Neumann, Patrick P. A1 - Lilienthal, A. J. ED - Eberhardsteiner, J. ED - Růžička, M. ED - Cosmi, F. T1 - Measuring rotor speed for wind vector estimation on multirotor aircraft JF - Materials Today: Proceedings N2 - For several applications involving multirotor aircraft, it is crucial to know both the direction and speed of the ambient wind. In this paper, an approach to wind vector estimation based on an equilibrium of the principal forces acting on the aircraft is shown. As the thrust force generated by the rotors depends on their rotational speed, a sensor to measure this quantity is required. Two concepts for such a sensor are presented: One is based on tapping the signal carrying the speed setpoint for the motor controllers, the other one uses phototransistors placed underneath the rotor blades. While some complications were encountered with the first approach, the second yields accurate measurement data. This is shown by an experiment comparing the proposed speed sensor to a commercial non-contact tachometer. T2 - 34th Danubia Adria Symposium on Advances in Experimental Mechanics CY - Trieste, Italy DA - 19.09.2017 KW - Wind vector estimation KW - Rotor speed KW - UAV KW - Tachometer PY - 2018 UR - https://www.sciencedirect.com/science/article/pii/S2214785318321114 DO - https://doi.org/10.1016/j.matpr.2018.08.139 SN - 2214-7853 VL - 5 IS - 13 SP - 26703 EP - 26708 PB - Elsevier CY - Amsterdam, Netherlands AN - OPUS4-47097 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hüllmann, Dino A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias T1 - Wind Vector Estimation on Multirotor Aircraft N2 - Small unmanned aircraft (UA) are used increasingly as flying sensor platforms. Amongst other things they are used for environmental monitoring, for example gas distribution mapping. Sometimes, these applications require knowledge of the ambient wind field, which can be measured by additional devices like anemometers. In general, it would be interesting to avoid such additional apparatuses. One way to achieve this is to estimate the wind vector, that is both the wind direction and speed, from the state variables of the UA. T2 - IEEE Sensors 2018 CY - New Delhi, India DA - 28.10.2018 KW - UAV KW - Wind vector KW - Estimation KW - Multirotor aircraft PY - 2018 AN - OPUS4-46479 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hüllmann, Dino A1 - Neumann, Patrick P. A1 - Kohlhoff, Harald A1 - Erdmann, Jessica T1 - Control of a spherical parallel manipulator with three degrees of freedom N2 - In robotic applications, it is often necessary to orient a sensor quickly. Spherical parallel manipulators (SPM) are well suited for this purpose since they offer superior dynamics and structural stiffness as compared to serial manipulators. To control them, however, the kinematic equations have to be known. In this paper, a SPM with three degrees of freedom and the kinematic equations describing its mechanical properties are presented. T2 - 35th Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Sinaia, Romania DA - 25.09.2018 KW - Spherical parallel manipulator KW - Control PY - 2018 AN - OPUS4-46142 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hüllmann, Dino A1 - Kohlhoff, Harald A1 - Erdmann, Jessica A1 - Neumann, Patrick P. ED - Pastramă, D. Ş. ED - Constantinescu, D. M. T1 - Control of a spherical parallel manipulator with three degrees of freedom T2 - 35th Danubia-Adria Symposium on Advances in Experimental Mechanics - Extended abstracts N2 - In robotic applications, it is often necessary to orient a sensor quickly. Spherical parallel manipulators (SPM) are well suited for this purpose since they offer superior dynamics and structural stiffness as compared to serial manipulators. To control them, however, the kinematic equations have to be known. In this paper, a SPM with three degrees of freedom and the kinematic equations describing its mechanical properties are presented. T2 - 35th Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Sinaia, Romania DA - 25.09.2018 KW - Spherical parallel manipulator KW - Control KW - 3 DoF PY - 2018 SN - 978-606-23-0874-2 SP - 159 EP - 160 PB - PRINTECH CY - Bukarest AN - OPUS4-46141 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hüllmann, Dino A1 - Neumann, Patrick P. A1 - Lilienthal, A. J. T1 - Gas Source Localisation from the Next Dimension N2 - Leaking methane (CH4) from infrastructures, like pipelines, industrial complexes and landfills, or accidental hazardous goods transports is critical for the environment, but can also pose a risk to human life. To enable a fast detection and localisation of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. The platform combines an unmanned micro aircraft (UAV), a 3-axis aerial stabilisation gimbal and an open-path gas detector based on the tunable diode laser absorption spectroscopy (TDLAS). T2 - PhD Poster Session an der Universität Örebro CY - Örebro, Sweden DA - 27.11.2018 KW - Gas Source Localisation KW - Mobile Robot Olfaction KW - UAV KW - TDLAS KW - Gas Spectroscopy PY - 2018 AN - OPUS4-46869 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hüllmann, Dino A1 - Neumann, Patrick P. A1 - Lilienthal, A. J. T1 - Aerial-based Gas Source Localisation using an Open-Path Gas Detector N2 - Presentation of the aerial robotic platform to localise gas sources with an open-path gas detector based on the tunable diode laser absorption spectroscopy (TDLAS) and project overview. T2 - Seminarserie an der Universität Örebro CY - Örebro, Sweden DA - 28.11.2018 KW - Gas Source Localisation KW - Gas Spectroscopy KW - UAV KW - TDLAS PY - 2018 AN - OPUS4-46870 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hofmann, Michael A1 - Tiebe, Carlo T1 - VDI/VDE 3518 - Technische Richtlinie für Multigassensoren T2 - Tagungsbericht - 5. HSN-Fachsymposium "Intelligente Sensorik/Analytik und sichere Sensornetze: Innovative Technologien und neue Anwendungsfelder" N2 - Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt. T2 - 5. Fachsymposium "Intelligente Sensorik/Analytik und sichere Sensornetze: Innovative Technologien und neue Anwendungsfelder" CY - Eggenstein -Leopoldshafen, Germany DA - 14.11.2018 KW - Multigassensoren KW - Richtlinie KW - Prüfung KW - Elektronische Nase PY - 2018 UR - http://hybridsensornet.org/symposien.html SP - 61 EP - 62 AN - OPUS4-46839 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hofmann, Michael A1 - Moufid, M. A1 - El Bari, N. A1 - Tiebe, Carlo A1 - Bouchikhi, B. T1 - Multigas Sensor System for Outdoor Odour Nuisance Monitoring N2 - The presentation gives a brief overview of the main goals, the used methods and the first results of the PMARS OdourSense project. In cooperation with the Moulay Ismaïl University in Meknès (Morocco), a multi-gas sensor system for odour nuisance monitoring in outdoor air and a method for testing/calibration of such devices are being developed in this project. T2 - German-Moroccan Workshop on PMARS III CY - Bonn, Germany DA - 20.06.2018 KW - Air-pollution monitoring KW - Multi-gas sensor system KW - Odour KW - Electronic nose KW - Outdoor odour control PY - 2018 AN - OPUS4-45266 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hofmann, Michael A1 - Tiebe, Carlo T1 - VDI/VDE 3518 Technische Richtlinie für Multigassensoren N2 - Der Beitrag präsentiert die erarbeiteten technischen Richtlinien zur Anwendung und Prüfung von Multigassensoren innerhalb der Richtlinienreihe VDI/VDE 3518 sowie in diesem Zusammenhang die Möglichkeiten der Sensorprüfung im akkreditierten Prüflabor des Fachbereichs 8.1 der BAM. Im Speziellen wird das in Kürze veröffentlichte Blatt 3 der Richtlinienreihe vorgestellt, das Bezug auf Multigassensoren für geruchsbezogene Messungen mit elektronischen Nasen nimmt. T2 - 5. Fachsymposium "Intelligente Sensorik/Analytik und sichere Sensornetze: Innovative Technologien und neue Anwendungsfelder" CY - Eggenstein-Leopoldshafen, Germany DA - 14.11.2018 KW - Multigassensoren KW - Richtlinie KW - Prüfung KW - Elektronische Nase PY - 2018 AN - OPUS4-46840 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Helmerich, Rosemarie A1 - Moldenhauer, Laura A1 - Voigt, Gerrit A1 - Köppe, E. T1 - Considerations for identification of moisture in building materials using Bluetooth (R) T2 - Maintenance, safety, risk, management and life-cycle performance of bridges N2 - The vulnerability of low-quality concrete of some bridges to ageing and deterioration while they are exposed to environmental conditions during their service life, influence of growing population and climate changes, is a well-known effect and requires survey. For survey, the development of a low cost, cost-efficient sensor network to be embedded for continuous or attached to the surface for periodic monitoring is essential. Changing ground water conditions, flood or even leakage in fresh or disposal of waste water can lead to in-creased moisture content in building materials and structural elements as walls or floors. Moisture allows the transport of other adverse chemicals that might reduce the durability of structures. The paper presents a feasibility study about the capability of microwave modules as bluetooth® or ZigBee with frequency range at 2,4 GHz to create advanced Wireless Sensor Networks (WSN) for estimation and visualization of moisture distribution in infrastructure assets. It was found that the value of the received signal strength indication (RSSI) depends on the moisture content and can be the basis for the moisture distribution inside a massive structure. The microwave modules may be used to compose networks outside and inside of building materials or structural elements. The higher the number of connections between BLE modules, the more precise and the more distant information can be obtained from the network. Mesh networking was applied to increase the quantitative information. T2 - 9th International Conference on Bridge Maintenance, Safety and Management (IABMAS) CY - Melbourne, Australia DA - 09.07.2018 KW - Structural Health Monitoring KW - Moisture KW - Bluetooth PY - 2018 SN - 978-1-315-18939-0 SN - 978-1-138-73045-8 SP - 2752 EP - 2759 AN - OPUS4-50340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Helmerich, Rosemarie ED - Hu, Chang Bin T1 - Engineering Education in Europe T2 - Glimpses of civil engineering education in the world N2 - The book chapter first analyses the history of higher education in Europe. Second step describes the current Bologna process. Finally, the rule of the Bundesanstalt für Materialforschung und -Prüfung (BAM) in supporting PhD-students during their research and preparation of theire theses in cooperation with Universities is described KW - History of education KW - Bologna process KW - BAM PY - 2018 SN - 978-7-114-14938-2 SP - 61 EP - 71 PB - China Communication Press Co., Ltd. CY - Fuzhou, China ET - 1. AN - OPUS4-46871 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ermawati, F. U. A1 - Supardi, Z. A. I. A1 - Suasmoro, S. A1 - Hübert, Thomas T1 - Contribution of Relaxation Effect to the Permittivity of Mg1-xZnxTiO3 Ceramics JF - IOP Conference Series: Materials Science and Engineering N2 - This work reported the investigation on the effect of relaxation to the permittivity (epsilon' r ) characteristic of Mg1-x Zn x TiO3 ceramics for x = 0 – 0.5 (MZT0 – MZT0.5) measured from 1 Hz to 330 MHz. Within that frequency range, the relaxation effect that consists of the space charge (SC) and the dipolar (D) polarization mechanisms were identified. The contribution of the D relaxation in MZT0 – MZT0.2 systems extents overall from about 100 Hz to 330 MHz, while that in MZT0.3 – MZT0.5 systems is from 50 kHz to 330 MHz. The remaining frequencies, i.e. from 1 to 90 Hz for MZT0 – MZT0.2 and from 1 Hz to 50 kHz for MZT0.3 – MZT0.5, are attributed to the SC relaxation. The D polarization mechanism provides constant epsilon' r values which vary from (15.4 – 17.0) ± 0.3 throughout the samples. Contribution of the SC polarization mechanism to the characteristic is supported by the simultaneous presence of different content and level of resistivity of the secondary phase of (Mg1-αZnα)2TiO4 in MZT0 – MZT0.2 systems and of (Zn1-αMgα)2TiO4 in MZT0.3 – MZT0.5, along with the presence of the main Mg1-x Zn x TiO3 phase, as a result of the variation of zinc content in the systems. T2 - The 5th International Conference on Advanced Materials Sciences and Technology (ICAMST 2017) CY - Makassar, Indonesia DA - 19.09.2017 KW - Dielectric ceramic KW - dipolar polarization KW - Mg1-xZnxTiO3 KW - permittivity KW - space charge polarization PY - 2018 DO - https://doi.org/10.1088/1757-899X/367/1/012003 SN - 1757-8981 VL - 367 SP - 1 EP - 6 PB - IOP Publishing Ltd AN - OPUS4-45618 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dzierliński, M. A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias ED - Zagrobelny, Maciej ED - Suś-Ryszkowska, Małgorzata T1 - Wykrywanie wycieków gazu za pomocą bezzałogowych pojazdów powietrznych T1 - Detection of gas leaks by unmanned aerial vehicles JF - Inspektor N2 - Wyciek metanu (CH4) z infrastruktury takiej jak rurociągi czy zbiorniki magazynowe ma kluczowe znaczenie dla środowiska oraz stwarza zagrożenie dla bezpieczeństwa ludzi i mienia. Obecnie, po okresie bezawaryjnej eksploatacji, można zaobserwować wzrost liczby incydentów spowodowanych nieszczelnościami rurociągów przesyłowych. W Polsce szczególnie problematyczne okazują się gazociągi, które powstały dekady temu. W tamtym czasie normy techniczne i przepisy budowlane były łagodniejsze niż obecnie obowiązujące. Integralność tych gazociągów jest trudna do skontrolowania, gdyż na etapie budowy nie zostały one przystosowane do badania tłokami pomiarowymi. Aby sprostać temu wyzwaniu, UDT poszukuje metod umożliwiających szybkie i niezawodne wykrywanie oraz lokalizowanie nieszczelności gazociągów na duże odległości. N2 - Methane leakage (CH4) from infrastructure such as pipelines or storage tanks is crucial for the environment and poses a threat to the safety of people and property. Today, after a period of failure-free operation, an increase in the number of incidents caused by leaks in transmission pipelines can be observed. In Poland, gas pipelines created decades ago turn out to be particularly problematic. At that time, technical standards and building regulations were milder than those currently in force. The integrity of these pipelines is difficult to control, as they were not adapted for testing with measuring pigs at the construction stage. To meet this challenge, UDT is looking for methods to quickly and reliably detect and locate leaks in pipelines over long distances. KW - Aerial robot KW - Mobile robot olfaction KW - Tomographic reconstruction of gas plumes KW - Tunable diode laser absorption Spectroscopy (TDLAS) KW - UAV-REGAS PY - 2018 UR - https://www.udt.gov.pl/inspektor-on-line VL - 4 SP - 19 EP - 21 PB - Urząd Dozoru Technicznego CY - Warszawa, Polska AN - OPUS4-47062 LA - pol AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dzierliński, M. A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias T1 - Towards UAV-based Detection of Leaking Gas Pipelines N2 - Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. Nowadays, after a period of failure-free exploitation, a significant increase in fires and explosions due to pipeline leakages, can be observed. Particularly problematic are the gas pipelines in Poland that were built several decades ago. At that time, the technical standards and building regulations were more lenient than those currently being in force. The integrity of the gas pipelines is difficult to inspect as they are not piston-optimized (they were not built for this purpose). To overcome this challenge, the UDT is looking for methods that enable a fast and reliable detection and localization of leaking pipelines over long distances. The BAM has developed a robotic platform for aerial remote gas sensing that meets the expectations of UDT. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer several advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of minicopters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile octocopter. It enables tomographic reconstruction of gas plumes and a localization of gas sources. Currently, UDT and BAM are cooperating to develop and validate an effective leakage detection method based on the UAV-REGAS platform. We present first results showing its performance under realistic conditions. Depending on the results, UDT may use this platform in their inspection practice in the near future. T2 - 1st EARSeL Workshop UAS “UAS for mapping and monitoring” CY - Warsaw, Poland DA - 05.09.2018 KW - UAV KW - Localization of gas sources KW - In-situ and remote gas sensing KW - Tunable Diode Laser Absorption Spectroscopy (TDLAS) KW - Wind estimation PY - 2018 AN - OPUS4-45991 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc A1 - Tiebe, Carlo A1 - Banach, Ulrich A1 - Ritter, U. T1 - Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren T2 - Sensoren und Messsysteme N2 - Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales. T2 - Sensoren und Messsysteme CY - Nuremberg, Germany DA - 26.06.2018 KW - Spurenfeuchtemessung KW - Sensorbeschichtung KW - Elektrolyseverfahren KW - Ionische Flüssigkeiten PY - 2018 SN - 978-3-8007-4683-5 SN - 0932-6022 SP - 520 EP - 523 PB - VDE VERLAG GMBH CY - Berlin, Offenbach AN - OPUS4-45319 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc A1 - Tiebe, Carlo A1 - Banach, Ulrich A1 - Ritter, U. T1 - Ionic Liquid Based Coulometric Trace Humidity Sensors T2 - ALLSENSORS 2018 N2 - This work presents a first attempt to use ionic liquids as a new coating for planar coulometric sensors. These sensors are used for the measurement of trace humidity in various gases. Usually, the coating of the sensors is tetraphosphorus decaoxide and its hydrolysis products. Instead, a hygroscopic ionic liquid was used as sensor coating in this work. Generated frost point temperatures tf in the gas ranged from -80 °C to -30 °C, which is equivalent to vapour mole fractions xv from 0.5 μmol·mol-1 to 376 μmol·mol-1. In addition to the coulometric sensors, the generated humidity is determined by a precision dew point hygrometer as reference. First results show that it is possible to measure humidity with ionic liquid based coulometric sensors. T2 - ALLSENSOR 2018 CY - Rom, Italy DA - 25.03.2018 KW - Ionic liquids. KW - Coulometric sensors KW - Sensor coating KW - Trace humidity measurement PY - 2018 SN - 978-1-61208-621-7 SP - 13 EP - 14 PB - IARIA AN - OPUS4-44609 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc A1 - Tiebe, Carlo A1 - Banach, Ulrich T1 - Influence of Gas Pressure on Coulometric Trace Humidity Measurement T2 - Proceedings of 17th International Meeting on Chemical Sensors 2018 N2 - Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors. T2 - 17th International Meeting of Chemical Sensors, IMCS 2018 CY - Vienna, Austria DA - 15.07.2018 KW - Gas pressure influence KW - Coulometric sensors KW - Trace humidity measurement PY - 2018 SN - 978-3-9816876-9-9 DO - https://doi.org/10.5162/IMCS2018/P2EC.7 SP - 715 EP - 716 PB - AMA Service GmbH CY - Wunstorf / Germany AN - OPUS4-45539 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Detjens, Marc A1 - Hübert, Thomas A1 - Tiebe, Carlo A1 - Banach, Ulrich T1 - Coulometric trace humidity measurement in technical gases JF - Review of scientific instruments N2 - Trace humidity was measured by using miniaturized planar coulometric sensors in technical gases such as hydrogen, nitrogen, helium, nitrous oxide, and synthetic air. Frost point temperatures tf in the gases ranged from −60 °C to −30 °C, which is equivalent to a vapour mole fraction xv from 10 μmol mol−1 to 376 μmol mol−1. In addition, the generated humidity was determined by using a precision dew point hygrometer as reference. Nonlinear calibration functions were calculated that correlated electric current (sensor signal) and reference humidity. Parameters of functions were tested with one-way analysis of variances (ANOVA) to prove if all used sensors had a similar behavior in the same gas during experiments. Results of ANOVA confirmed that averaged functions can be applied for trace humidity measurement in nitrogen, helium, nitrous oxide, and synthetic air. The calculated functions were negligibly different for nitrogen, helium, and synthetic air. In humidified nitrous oxide, a minor change of parameters was observed due to lower electrical currents. In total contrast to that, the measured sensor signals were significantly higher in humidified hydrogen and each sensor required its own calibration function. The reason was a recombination effect that favoured multiple measurements of water molecules. Nevertheless, it was possible to measure continuously trace humidity in all tested gases by using coulometric sensors with an expanded uncertainty below 2 K (k = 2). KW - ANOVA KW - Trace humdity measurement KW - Coulometric sensors KW - Chemical sensors KW - Measurement uncertainty PY - 2018 DO - https://doi.org/10.1063/1.5008463 SN - 0034-6748 SN - 1089-7623 VL - 89 IS - 8 SP - 085004, 1 EP - 8 PB - American Institute of Physics (AIP) CY - Maryland (USA) AN - OPUS4-45956 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc A1 - Tiebe, Carlo A1 - Banach, Ulrich A1 - Ritter, U. T1 - Ionic Liquid Based Coulometric Trace Humidity Sensors N2 - This work presents a first attempt to use ionic liquids as a new coating for planar coulometric sensors. These sensors are used for the measurement of trace humidity in various gases. Usually, the coating of the sensors is tetraphosphorus decaoxide and its hydrolysis products. Instead, a hygroscopic ionic liquid was used as sensor coating in this work. Generated frost point temperatures tf in the gas ranged from -80 °C to -30 °C, which is equivalent to vapour mole fractions xv from 0.5 μmol·mol-1 to 376 μmol·mol-1. In addition to the coulometric sensors, the generated humidity is determined by a precision dew point hygrometer as reference. First results show that it is possible to measure humidity withionic liquid based coulometric sensors. T2 - ALLSENSOR 2018 CY - Rom, Italy DA - 25.03.2018 KW - Ionic liquids KW - Coulometric sensors KW - Sensor coating KW - Trace humidity measurement PY - 2018 AN - OPUS4-44601 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc A1 - Tiebe, Carlo A1 - Banach, Ulrich A1 - Ritter, U. T1 - Ionische Flüssigkeiten als neuartige Sensorbeschichtung für coulometrische Spurenfeuchtesensoren N2 - Die Arbeit präsentiert erste Messungen mit coulometrischen Sensoren, die mit einer ionischen Flüssigkeit beschichtet sind. Diese Sensoren werden in der Industrie verwendet, um die Spurenfeuchte in unterschiedlichen Gasen zu messen. Normalerweise erfolgt eine Beschichtung der Sensoren mit Phosphorpentoxid und dessen Hydrolyseprodukte. In dieser Arbeit wurde stattdessen eine hygroskopische ionische Flüssigkeit benutzt. Die generierte Gasfeuchte für die Untersuchungen betrug bezogen auf die Frostpunkttemperatur -80 °C bis -30 °C, was gleichbedeutend mit einem Wasserdampf-Stoffmengenanteil von 0,5 μmol·mol-1 bis 376 μmol·mol-1 ist. Zusätzlich zu der Messung mit coulometrischen Sensoren erfolgte eine Referenzmessung der Gasfeuchte mittels eines Taupunkthygrometers. Erste Ergebnisse haben gezeigt, dass es möglich ist mit dieser Art der Beschichtung unterschiedliche Gasfeuchten zu messen. Aber es ergaben sich trotz gleicher Feuchte unterschiedliche Signalintensitäten bei den benutzen Sensoren und es zeigte sich eine Drift des Sensorsignales. T2 - Sensoren und Messsysteme CY - Nuremberg, Germany DA - 26.06.2018 KW - Spurenfeuchtemessung KW - Elektrolyseverfahren KW - Ionische Flüssigkeiten KW - Sensorbeschichtung PY - 2018 AN - OPUS4-45318 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc A1 - Tiebe, Carlo A1 - Banach, Ulrich T1 - Influence of Gas Pressure on Coulometric Trace Humidity Measurement N2 - Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors. T2 - 17th International Meeting of Chemical Sensors, IMCS 2018 CY - Vienna, Austria DA - 15.07.2018 KW - Gas pressure influence KW - Coulometric sensors KW - Trace humidity measurement PY - 2018 AN - OPUS4-45535 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc T1 - Elektrolyseverfahren zur Bestimmung der Spurenfeuchte N2 - Die Spurenfeuchte ist eine wichtige Messgröße bei der Qualitätsbeurteilung von technischen und medizinischen Gasen und muss daher zuverlässig gemessen werden. Der Spurenbereich ist definiert durch einen Wasserdampf-Stoffmengenanteil kleiner als 2600 µmol/mol bzw. einer Frostpunkttemperatur kleiner -10 °C. Eine geeignete Methode für die kontinuierliche Spurenfeuchtemessung stellt das Elektrolyseverfahren bzw. coulometrische Messprinzip dar. Bei diesem Prinzip strömt ein feuchtes Gas über eine hygroskopische Phosphorpentoxid-Schicht, welche kontinuierlich Wasserdampf absorbiert. Durch das Anlegen einer Zersetzungsspannung wird das absorbierte Wasser elektrolysiert und der resultierende Elektrolysestrom korreliert zum Feuchtegehalt im Gas. Neben dem Einfluss von unterschiedlichen Gasen auf das Messverfahren, wurde der Einfluss der Druckfeuchte im Druckbereich von 2 bis 15 bar untersucht. Des Weiteren wurde eine neuartige Sensorbeschichtung basierend auf einer ionischen Flüssigkeit getestet und es wurde ein Prototyp für die abgestufte Bestimmung der Wasseraktivität und der Materialfeuchte aufgebaut. T2 - Seminar am Institut für Chemie und Biotechnik CY - Technische Universität Ilmenau, Ilmenau, Germany DA - 06.06.2018 KW - Elektrolyseverfahren KW - Spurenfeuchte in Gasen KW - Druckfeuchte KW - Materialfeuchte KW - Ionische Flüssigkeit PY - 2018 AN - OPUS4-45122 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Daum, Werner A1 - Czichos, Horst ED - Grote, Karl-Heinrich ED - Bender, Beate ED - Göhlich, Dietmar T1 - Messtechnik und Sensorik T2 - DUBBEL - Taschenbuch für den Maschinenbau N2 - Für den allgemeinen Maschinenbau wichtige Messtechnik und Sensorik werden grundlegend und anwendungsbezogen beschrieben. KW - Messtechnik KW - Sensorik KW - Maschinenbau PY - 2018 SN - 978-3-662-54804-2 DO - https://doi.org/10.1007/978-3-662-54805-9 SP - W 2 EP - W 44 PB - Springer Vieweg CY - Berlin ET - 25 AN - OPUS4-47132 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Mitzkus, Anja A1 - Sahre, Mario A1 - Weise, Matthias A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Basedau, Frank A1 - Hofmann, Detlef A1 - Schukar, Vivien T1 - Faser-basierter magneto-optischer Schicht-Sensor zum Monitoring von Bauteilen T2 - 13. ThGOT Thementage Grenz- und Oberflächentechnik und 11. Thüringer Biomaterial-Kolloquium N2 - In Glasfasern eingeschriebene Bragg-Gitter (FBG: fibre-based Bragg gratings) sind über die Verschiebung der Bragg-Wellenlänge in der Lage, Stauchungen und Dehnungen von Glasfasern hochgenau zu erfassen. In Kompositwerkstoffe eingebettete faseroptische Sensoren können Bauteile bezüglich ihrer mechanischen Integrität überwachen und früh-zeitig Informationen über Materialveränderungen gewinnen. Um die Zuverlässigkeit eines solchen Sensors zu gewährleisten, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit der Werkstoff-Matrix on-line und in-situ sicherzu-stellen. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnosefähiger Schichtsensor entwickelt, der mit Hilfe von magnetostriktiven Aktorschichten aus Nickel bzw. Eisen-Nickel validiert werden kann. Der FAMOS²-Schichtsensor wird durch ein PVD (physical vapour deposition)/ECD (electro-chemical deposition) Hybridschichtsystem realisiert, das auf dem Fasermantel im Bereich des FBG haftfest, homogen und langzeitfunktional abzuscheiden ist. Dabei wird in einem ersten Schritt ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer als Haftvermittler auf der Glasfaser bzw. als leitfähige Startschicht für den nachfolgenden ECD-Prozess abgeschieden. Um eine rotationssymmetrische Schich-tabscheidung zu gewährleisten, erfolgt während der PVD-Beschichtung eine Rotation der Glasfasern. In einem zweiten Schritt wird dann unter Verwendung eines klassischen Watts-Elektrolyten in einer speziell entwickelten ebenfalls rotationssymmetrisch aufgebau-ten ECD-Durchströmungszelle dann die etwa 30 Mikrometer dicke, magnetostriktive Ak-torschicht auf dem PVD-Schichtsystem abgeschieden, im Vergleich sowohl reine Nickel-Schichten als auch Nickel-Eisen-Schichten. Ein äußeres Magnetfeld dehnt die magnetostriktive Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke eines zu messenden oder zu Validierungszwecken vorgegebenen Magnetfeldes korreliert. Die Anpassung der Beschichtungsverfahren an die Fasergeome-trie und die mechanischen Eigenschaften der Hybridschichten werden hinsichtlich der me-chanischen Integrität des faseroptischen Sensors diskutiert und der Nachweis der Selbst-diagnosefähigkeit erbracht. T2 - 13. ThGOT Thementage Grenz- und Oberflächentechnik und 11. Thüringer Biomaterial-Kolloquium CY - Zeulenroda, Germany DA - 13.03.2018 KW - Magneto-optischer Sensor KW - Faser-Bragg Gitter KW - Magnetostriktive Beschichtung KW - Selbstkalibrierung KW - Bauteilmonitoring PY - 2018 SN - 978-3-00-058187-8 SP - 1 EP - 5 CY - Jena AN - OPUS4-44599 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Mitzkus, Anja A1 - Sahre, Mario A1 - Weise, Matthias A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Basedau, Frank A1 - Hofmann, Detlef A1 - Schukar, Vivien T1 - Faser-basierter magneto-optischer Schicht-Sensor zum Monitoring von Bauteilen N2 - In Glasfasern eingeschriebene Bragg-Gitter (FBG: fibre-based Bragg gratings) sind über die Verschiebung der Bragg-Wellenlänge in der Lage, Stauchungen und Dehnungen von Glasfasern hochgenau zu erfassen. In Kompositwerkstoffe eingebettete faseroptische Sensoren können Bauteile bezüglich ihrer mechanischen Integrität überwachen und früh-zeitig Informationen über Materialveränderungen gewinnen. Um die Zuverlässigkeit eines solchen Sensors zu gewährleisten, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit der Werkstoff-Matrix on-line und in-situ sicherzu-stellen. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnosefähiger Schichtsensor entwickelt, der mit Hilfe von magnetostriktiven Aktorschichten aus Nickel bzw. Eisen-Nickel validiert werden kann. Der FAMOS²-Schichtsensor wird durch ein PVD (physical vapour deposition)/ECD (electro-chemical deposition) Hybridschichtsystem realisiert, das auf dem Fasermantel im Bereich des FBG haftfest, homogen und langzeitfunktional abzuscheiden ist. Dabei wird in einem ersten Schritt ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer als Haftvermittler auf der Glasfaser bzw. als leitfähige Startschicht für den nachfolgenden ECD-Prozess abgeschieden. Um eine rotationssymmetrische Schich-tabscheidung zu gewährleisten, erfolgt während der PVD-Beschichtung eine Rotation der Glasfasern. In einem zweiten Schritt wird dann unter Verwendung eines klassischen Watts-Elektrolyten in einer speziell entwickelten ebenfalls rotationssymmetrisch aufgebau-ten ECD-Durchströmungszelle dann die etwa 30 Mikrometer dicke, magnetostriktive Ak-torschicht auf dem PVD-Schichtsystem abgeschieden, im Vergleich sowohl reine Nickel-Schichten als auch Nickel-Eisen-Schichten. Ein äußeres Magnetfeld dehnt die magnetostriktive Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke eines zu messenden oder zu Validierungszwecken vorgegebenen Magnetfeldes korreliert. Die Anpassung der Beschichtungsverfahren an die Fasergeome-trie und die mechanischen Eigenschaften der Hybridschichten werden hinsichtlich der me-chanischen Integrität des faseroptischen Sensors diskutiert und der Nachweis der Selbst-diagnosefähigkeit erbracht. T2 - 13. ThGOT Thementage Grenz- und Oberflächentechnik und 11. Thüringer Biomaterial-Kolloquium CY - Zeulenroda, Germany DA - 13.03.2018 KW - Magneto-optischer Sensor KW - Faser-Bragg Gitter KW - Magnetostriktive Beschichtung KW - Selbstkalibrierung KW - Bauteilmonitoring PY - 2018 AN - OPUS4-44598 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Fischer, Daniel A1 - Hertwig, Andreas A1 - Mitzkus, Anja A1 - Sahre, Mario A1 - Weise, Matthias A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Basedau, Frank A1 - Hofmann, Detlef A1 - Schukar, Vivien A1 - Kormunda2, M. T1 - Multi-functional coatings for optical sensor applications: Surface plasmon resonance & magneto-optical coupling N2 - Multi-functional coatings are a key requirement for surface engineering. General demands are adhesion and long-term stability under service conditions. The modification of surfaces by means of PVD-, ECD- or hybrid processes allows an add-on functionalization of surfaces by a huge diversity of materials with both lateral and vertical micro-/nano-designs. This fact is a prerequisite for micro- and sensor-systems in lab-on-chip and sensor-on-chip technology. Two layer-based sensor principles are presented, i.e. surface plasmon resonance enhanced spectroscopic ellipsometry (SPREE) for detection of hazardous gases and magneto-optical sensors on smart-coated fiber Bragg gratings (FBG) for structural health monitoring (SHM). The interdependence of substrate features, coating properties, and layer design is discussed firstly for gas sensitivity and selectivity of SPREE-sensors and secondly for sensitivity and selectivity of magneto-strictive coatings to mechanical strain or external magnetic fields resulting in an optical displacement of the Bragg wavelength of FBG-sensors. Moreover, generic features such long-term stability, crucial process-related fabrication conditions, and effects of operational and environmental parameters are discussed with respect to the sensor performance. It has been shown that appropriate layer design and adapted selection of layer materials (SnOx/Au, Fe/Ni:SnOx/Au; Ni/NiFe-Cu-Cr) result in improved sensor parameters and may enable new sensor applications. T2 - SVC TechCon 2018 CY - Orlando, FL, USA DA - 05.05.2018 KW - Multi-functional coatings for sensors KW - Surface plasmon resonance enhanced ellipsometry (SPREE) KW - Gas monitoring KW - Magneto-optical coupling (MOC) KW - Structural health monitoring (SHM) PY - 2018 AN - OPUS4-44976 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Tiebe, Carlo A1 - Neumann, Patrick P. T1 - Two tasks in environmental monitoring - calibration and characterization of gas sensors and remote gas sensing with multicopter platforms - Part 1 N2 - Leaking methane from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, BAM developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the copter downwash on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile multicopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available systems and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions. T2 - Aarhus University, Department of Environmental Science, External seminar with Matthias Bartholmai and Carlo Tiebe CY - Roskilde, Denmark DA - 29.08.2018 KW - Environmental monitoring KW - Remote gas sensing KW - Flying platforms KW - Mobile robot olfaction KW - UAS PY - 2018 AN - OPUS4-45838 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Schütze, A. T1 - Sensor network deployment N2 - Content • Fixed monitoring stations • Mobile monitoring stations (on trams, buses, cars) • Personal mobile monitoring systems • Environmental monitoring for agriculture and beyond • Sensors on flying platforms T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Environmental monitoring KW - Gas sensors PY - 2018 AN - OPUS4-44073 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Neumann, Patrick P. A1 - Tiebe, Carlo A1 - Johann, Sergej T1 - Adaptable multi-sensor device for gas detection N2 - Innovation is the catalyst for the technology of the future. It is important to develop new and better technologies that can continuously monitor the environmental impact, e.g., for air Quality control or emission detection. In the recently at BAM developed Universal Pump Sensor Control (UPSC3) module, different components and sensors are fused. The combination of the individual components makes the UPSC3 module an excellent monitoring and reference system for the development and characterization of gas specific sensors. Measurements over long periods are possible, for mixed gas loads or for certain gas measurements. The System is part of a mobile sensor network of several sensor units, which can also be used as standalone systems. T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Environmental monitoring PY - 2018 AN - OPUS4-44077 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Neumann, Patrick P. A1 - Tiebe, Carlo T1 - KonSens - Kommunizierende Sensorsysteme für die Bauteil- und Umweltüberwachung N2 - Im Projekt KonSens werden für die Anwendungsbei- spiele bauteilintegrierte Sensorik für Betonkomponen- ten und mobile Multigassensorik Sensorsysteme in Form von Funktionsmustern entwickelt, validiert und angewendet. Schwerpunkte liegen einerseits in der Detektion und Bewertung von Korrosionsprozessen in Beton und andererseits in der Detektion und Quantifi- zierung sehr geringer Konzentrationen toxischer Gase in der Luft. Dabei ist die Adaption der sensorischen Methoden aus dem Labor in reale Messumgebungen inklusive geeigneter Kommunikationstechnik ein wichtiger Aspekt. T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Umweltmonitoring KW - Bauwerksüberwachung PY - 2018 AN - OPUS4-44074 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter T1 - Temperature characteristics of a piezoresistive accelerometer for high impact shock application N2 - This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison. T2 - Sensoren und Messsysteme CY - Nürnberg, Germany DA - 26.06.2018 KW - Piezoresistive accelerometer KW - Hopkinson bar KW - High impact shock application KW - Temperature characteristics KW - Drop test PY - 2018 AN - OPUS4-45322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias ED - Werner, Klaus-Dieter T1 - Temperature characteristics of a piezoresistive accelerometer for high impact shock application T2 - ITG-Fachbericht 281 Sensoren und Messsysteme 2018 N2 - This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison. T2 - Sensoren und Messsysteme CY - Nürnberg, Germany DA - 26.06.2018 KW - Piezoresistive accelerometer KW - High impact shock application KW - Drop test KW - Temperature characteristics KW - Hopkinson bar PY - 2018 SN - 978-3-8007-4683-5 SN - 0932-6022 SP - 465 EP - 467 PB - VDE Verlag GmbH CY - Berlin AN - OPUS4-45323 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter T1 - Comparison of the Temperature Behavior of Oil and Gas Damped Piezoresistive Accelerometers N2 - This study presents the characterization of a piezoresistive accelerometer damped with silicon oil for the application in drop tests carried out at BAM. Experiments were performed with the Hopkinson Bar method in close correlation to the real-world application conditions. The results point out certain limitations regarding the temperature influence and the frequency response. Additional experiments were performed with a gas damped type of piezoresistive accelerometer, which has superior specifications, particularly for low temperatures. The results allow for a comparison. T2 - IEEE SENSORS 2018 CY - Neu Delhi, Indien DA - 28.10.2018 KW - Accelerometer KW - Temperature behavior KW - Frequency response KW - Hopkinson Bar KW - Drop test PY - 2018 AN - OPUS4-46484 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartelmeß, Jürgen A1 - Gawlitza, Kornelia A1 - Tiebe, Carlo A1 - Bartholmai, Matthias A1 - Rurack, Knut T1 - Developments Towards a fluorometric sensing device for multiple hazardous gases N2 - Fluorometric sensing is a versatile approach for trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them as superior active component for the preparation of optical sensor devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents,illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications. In the interdisciplinary approach presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable. The dyes presented follow a “turn-on” fluorescence schematic, which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing. Further steps in the project include the assembly of instruments for test-atmosphere generation, the referencing of the sensor system, development and implementation of an optical setup, and the testing of the prototype device under laboratory conditions and in the field. In this presentation, we give an overview over the recent developments on this topic in our groups, including fluorophore designs investigated for the detection of benzene, ammonia, and hydrogen sulfide as well as approaches for the design of the sensing device. T2 - EUROPT(R)ODE XIV CY - Neapel, Italy DA - 25.03.2018 KW - Gas sensor KW - Fluorometric sensing KW - BODIPY dye PY - 2018 AN - OPUS4-45645 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartelmeß, Jürgen A1 - Gawlitza, Kornelia A1 - Kraus, Werner A1 - Chlvi-Iborra, Katherine A1 - Tiebe, Carlo A1 - Noske, Reinhard A1 - Bartholmai, Matthias A1 - Rurack, Knut T1 - Developments Towards a BODIPY-based fluorometric sensing device for multiple hazardous gases N2 - Fluorometric sensing is a versatile approach for trace analysis outside of the laboratory, requiring suitable sensor materials and their integration into sensing devices. The versatility of fluorophores as probes, especially in terms of the possibility to tailor their optical as well as their recognition properties by synthetic modifications in a wide range, renders them as superior active component for the preparation of optical sensing devices. Recent works at BAM in this field include, for example, the detection of nerve gas agents, illustrating impressively the aforementioned benefits of fluorophores in optical sensing applications. In the interdisciplinary project presented here, we target hazardous gases such as ammonia, benzene, and hydrogen sulfide, next to others, which pose a major threat to human health and environmental safety and for which the availability of a sensitive and reliable detection method is highly desirable. The dyes presented follow a “turn-on” fluorescence schematic, which allows for the selective and sensitive detection of the respective gaseous analyte. The immobilization of the probe in polymeric matrices is then the next step toward the fabrication of a prototype device for molecular sensing. Further steps in the project include the assembly of instruments for test-atmosphere generation, the referencing of the sensor system, development and implementation of an optical setup, and the testing of the prototype device under laboratory conditions and in the field. In this presentation, we give an overview over the recent developments on this topic in our groups. Highlights are hydrogen sulfide sensitive, BODIPY based transition metal complexes, which allow for a sensitive as well as selective detection of the toxic gas. In addition, we present a novel class of highly substituted BODIPY derivatives – pocket-BODIPYs – which are of a synthetically high versatility and can readily be modified to create pockets in the periphery of the molecule of defined geometries. This is illustrated on the successful encapsulation of benzene by a pocket-BODIPY derivative, confirmed by X-ray crystallographic analysis as well as by further spectroscopic and analytical methods. T2 - International Conference on Porphyrins and Phthalocyanins (ICPP-10) CY - Munich, Germany DA - 01.07.2018 KW - BODIPY dye KW - Fluorometric sensing KW - Gas sensing PY - 2018 AN - OPUS4-45646 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Baensch, Franziska A1 - Hüsken, Götz A1 - Pirskawetz, Stephan A1 - Gründer, Klaus-Peter A1 - Kadoke, Daniel A1 - Baer, Wolfram A1 - Wossidlo, Peter A1 - Homann, Tobias A1 - Prager, Jens A1 - Stajanca, Pavol A1 - Habib, Abdel Karim A1 - Zauner, Michaela A1 - Sause, Markus G. R. A1 - Vergeynst, Lidewei A1 - Brunner, Andreas J. A1 - Niemz, Peter T1 - Acoustic emission testing N2 - The phenomenon of acoustic emission (AE) and fundamentals of AE testing procedures are presented. AE based failure analysis of reinforced concrete beam under bending load, steel pipe segments under bending load and wood based materials under tension load are discussed. T2 - INFRASTAR, Training Week #03 at AAU CY - Aalborg, Denmark DA - 04.06.2018 KW - Acoustic emission PY - 2018 AN - OPUS4-45147 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Baensch, Franziska T1 - Acoustic Emission T1 - Überwachung und Charakterisierung von Werkstoffen mittels Schallemissionsanalyse N2 - Das Phänomen Schallemission (eng. Acoustic Emission, AE) ist eine Begleiterscheinung bei aktiven Mechanismen und Prozessen wie sie in Werkstoffen auftreten, die einer Belastung durch Krafteinwirkung oder durch Änderung der Umgebungsbedingungen ausgesetzt sind. Plastische Verformung, Risswachstum, Korrosion oder der Übergang zu einer anderen Phase generieren u.a. transiente elastische Wellen, die sich im Werkstoff und an der Materialoberfläche ausbreiten. Auftretende Auslenkungen von wenigen hundert Pikometern sind mit piezo-elektrischen AE Sensoren detektierbar. Aufzeichnungsraten von bis zu 40 MHz ermöglichen dabei zeitliche Auflösungen von einigen Nano- bis Mikrosekunden. Die Dechiffrierung der detektierten Informationen ist für die Material- und Versagenscharakterisierung sowie für Anwendungen in der Struktur- oder Prozessüberwachung ein zentraler Forschungsschwerpunkt. Nach einem kurzen Überblick zu den Grundlagen werden ausgewählte Ansätze der AE Methode vorgestellt und diskutiert: 1) AE Monitoring von Pipelines als Referenzmessung für die Entwicklung eines akustischen faseroptischen Monitorings (AGIFAMOR) 2) Schwellwertfreie AE Messung im 4-Punkt-Rohrbiegeprüfstand BAM_9.1 (AGIFAMOR) 3) Kombination von AE mit Röntgen-Mikrotomografie und die Anwendung der frequenzbasierten Mustererkennung ermöglichen eine Zuordnung von AE und Mechanismen (Ergebnisse aus dem SNSF Projekt Nr. 127'134, Baensch 2014, Diss. ETH No. 22372) T2 - Abteilungsseminar BAM-8.1 CY - BAM UE, Berlin, Germany DA - 08.10.2018 KW - Acoustic Emission (AE) KW - Monitoring KW - Non-threshold measurement KW - Unsupervised pattern recognition PY - 2018 AN - OPUS4-46202 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -