TY - CHAP A1 - Hübert, Thomas A1 - Tiebe, Carlo A1 - Banach, Ulrich ED - Rodriguez Mendez, M. T1 - Electronic Noses for the Quality Control of Spices N2 - The chapter describes the application of electronic noses (multigas sensors) for the quality control of spices and spice mixtures. Electronic noses were successfully applied for headspace analysis of spices. It was demonstrated in many investigations that electronic noses can contribute to the characterization of spices and spice mixtures in order to distinguish spices and spice mixtures, differentiate by origin, growth seasons,and processing,indicate adulteration from original, detect mold infestation. Electronic noses can be used as a fast screening method to provide information about the product quality. However, it needs samples and methods for reference, careful training, and complex calibration to consider influencing and disturbing effects as well as the possible limitations of the instrumentation. The correlation to classical chemical analysis methods is always advisable. Machined olfaction methods are capable to support the sensory analysis; however, they cannot yet substitute them. KW - Spice KW - Electronic Nose KW - Multigas sensor KW - Quality control PY - 2016 SN - 978-0-12-800243-8 DO - https://doi.org/10.1016/B978-0-12-800243-8.00012-3 SP - Chapter 12, 115 EP - 124 PB - Academic Press CY - Oxford AN - OPUS4-35443 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Gawlitza, Kornelia T1 - Gas standards for the calibration of novel fluorescence sensors for ammonia N2 - Ammonia and its conversion product ammonium have a strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the molar fraction range (0.5 to 500) nmol/mol. There is a need for reliable traceable ammonia gas standards as well as in situ analytical procedures for the monitoring of ammonia in ambient air. The permeation method is an effective tool for dynamically generating precise gas standards with a low uncertainty in the concentration range of a few nmol/mol to several µmol/mol in an inert carrier gas, e. g. pure nitrogen or purified ambient air. Here, we present our ammonia gas standard generator as well as results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. In order to detect ammonia in the nmol/mol-range, a suitable sensor has to be developed. In this contribution, we therefore additionally present first approaches on the development of such a sensor using optical fluorescence as transduction mechanism due to its intrinsically high sensitivity and high spatial resolution. Incorporation of a fluorescent dye, which shows fluorescence enhancement in the presence of ammonia, into a polymer matrix allows to reversibly recognize low amounts of ammonia. It can be concluded that fluorescence sensor is a robust tool for measurements of ammonia; however it needs calibration for the planed use. T2 - MetNH3-workshop on the progress in ammonia metrology CY - Braunschweig, Germany DA - 24.02.2016 KW - Ammonia KW - Fluorescence sensor KW - Permeation KW - Test gas generation PY - 2016 AN - OPUS4-35810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sieg, H. T1 - Artificial digestion of aluminium-containing nanomaterials and their effects on the gastrointestinal tract in vitro N2 - Although aluminium is one of the most common elements in the biosphere, up to now little is known about its impact on human health. aluminium and its chemical derivatives are highly abundant in food, food contact materials and consumer products. Humans are exposed to aluminium via the gastrointestinal tract (GI tract). Exposition can change substantially due to consumer behavior since aluminium is also a compound of numerous food additives. Recently, aluminium exposition is increasingly considered to cohere with cancer and neurodegenerative disorders. Lately, due to an increasing attentiveness on this topic, limiting values for food additives have been tightened by the EFSA. However, cellular effects of aluminium and especially aluminium-containing nanomaterials, that represent a significant part of chemicals found in food products, are widely unknown and in the focus of our research activities, for example in the bilateral SolNanoTOX project. We established an in vitro simulation system of the GI tract, where nanomaterials undergo the different physiological, chemical and proteinbiochemical conditions of saliva, gastric juice and the intestine. The artificially digested nanomaterials, as well as soluble aluminium chloride as ionic control substance, were subjected to several analytical and biochemical methods to characterize their change of appearance and their cytotoxic effects on intestinal cellular models. We observed the fate of the nanomaterials during typical pH-values of saliva, gastric and intestinal juice with Dynamic light scattering measurements and ICP-MS in the single particle mode. After observable disappearance at pH 2 the particles recovered in the simulated intestinal fluid. The simulation of the GI tract, mainly the change of pH settings, can lead to a certain chemical activation of aluminium that can increase bioavailability in the intestine after oral uptake of aluminium-containing food products. In vitro assays like CTB, MTT and cellular impedance measurements showed that there were no acute cytotoxic effects measurable after a period up to 48h after incubation, comparable to undigested particles. In contrast, high amounts of aluminium ions showed synergistic effects on cell viability compared to non-digested aluminium ions. Although toxicological potential of Al ions to healthy tissue appears to be low, increased hazardous potential cannot be ruled out to pre-damaged tissue and can have a relevance in risk assessment for special consumer groups with for example chronical intestinal inflammation or dietary eating behavior combined with high exposure to Al-containing food products. T2 - 82nd Annual Meeting of the German Society for Experimental and Clinical Pharmacology and Toxicology CY - Berlin, Germany DA - 29.02.2016 KW - Nanoparticles KW - Digestion KW - SAXS KW - Cytotoxicity PY - 2016 AN - OPUS4-36026 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kästner, Claudia T1 - Aggregation and deaggregation of silver nanoparticles - what does your gut say? N2 - Due to the increasing utilization of silver nanoparticles in consumer related products, many studies focus on investigations regarding their toxicological potential. This includes investigations concerning uptake, distribution and excretion of the particles. So far, little attention was paid to changes of physical and chemical properties in the human body. During processes like digestion, the question arises whether they can pass this barrier in a nanoscale form. In this study we analytically monitored the changes in the size distribution of silver nanoparticles during an artificial digestion process with the help of small angle x-ray scattering (SAXS). Therefore, we synthesized polyacrylic acid stabilized ultra-small silver nanoparticles with a radius of 3 nm and a size distribution width of 18%. The artificial digestion process mimics the gastro-intestinal passage and simulates the oral, gastric and small intestinal conditions. Additionally, food components like oil, starch, glucose and skimmed milk powder are used to provide a preferably realistic environment. In absence of any food components the low pH initiates aggregation of the particles in the stomach. However, the particles unexpectedly stabilize in a defined cluster form with a mean radius of 12 nm. By the use of the food components oil and starch we observed that the particles are dispersed again. Now we found a bimodal size distribution of primary particles and aggregates. In contrast to that, with skimmed milk powder only a slight aggregation occurs in the stomach. In the gastric tract the particle distribution is stabilized at a mean volume weighted radius of 5 nm. Hence, skimmed milk powder acts as a colloidal stabilizer. For comparison we also used silver nitrate as a control substance. Surprisingly, we observed a formation of nanoparticles already in the saliva. During the digestion process the distribution narrows and finally in the intestine it shows a stable distribution with a mean volume weighted radius of 3 nm and a small fraction of aggregates. These results indicate that the silver nanoparticles can pass the biological barriers of the digestion process in a nanoscale form but undergo a transformation in the size distribution. However, even from pure silver nitrate nanoparticle formation can be observed. This sketches a complex mechanism in which not only food components but also silver ions cause changes in nanoparticle size and aggregation. T2 - 11th International Conference on Biological Barriers CY - Saarbrücken, Germany DA - 07.03.2016 KW - digestion KW - small-angle X-ray scattering KW - silver nanoparticles PY - 2016 AN - OPUS4-35539 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brieger, C. A1 - Melke, J. A1 - van der Bosch, N. A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - de Oliveira Guilherme Buzanich, Ana A1 - Krishna Kayarkatte, M. A1 - Schoeckel, A. A1 - Roth, C. T1 - A combined in-situ XAS-DRIFTS study unraveling adsorbate induced changes on the Pt nanoparticle structure N2 - The adsorption behavior of Platinum nanoparticles was studied for the as-received catalyst (under inert gas), under hydrogen and CO atmosphere using our newly designed in-situ cell. X-ray Absorption Spectroscopy (XAS) and Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS) experiments were performed simultaneously with high data quality. Structural information and the type of adsorbate could be revealed via Extended X-ray Absorption Fine Structure (EXAFS) analysis, Dl X-ray Absorption Near Edge Structure analysis (Dl XANES) and in-situ DRIFTS. The as-received catalyst showed sub-surface oxygen and O(n-fold). Under CO atmosphere only CO(atop) was found. Reversible adsorbate induced changes of the Pt nanoparticle structure were derived from changes in the PtAPt coordination number and the corresponding bond distance. Under reducing conditions (H2, CO) a significant increase in both values occurred. Temperature dependent desorption of CO revealed a gradual shift from PtACO to PtAO. Reoxidation was clearly assigned to strong metal support interaction from the SiO2 support. KW - X-ray absorption spectroscopy KW - DRIFTS KW - XANES KW - CO adsorption KW - Platinum KW - Strong metal support interaction KW - Silica support KW - Adsorbates KW - Infrared spectroscopy PY - 2016 DO - https://doi.org/10.1016/j.jcat.2016.03.034 IS - 339 SP - 57 EP - 67 PB - Elsevier Inc. CY - Philadelphia, Pennsylvania, USA AN - OPUS4-35815 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Unger, Wolfgang A1 - Beiranvand, Z. A1 - Kakanejadifard, A. A1 - Donskyi, Ievgen A1 - Faghani, A. A1 - Tu, Z. A1 - Lippitz, Andreas A1 - Sasanpour, P. A1 - Maschietto, F. A1 - Paulus, B. A1 - Haag, R. A1 - Adeli, M. T1 - Functionalization of fullerene at room temperature: toward new carbon vectors with improved physicochemical properties N2 - In this work, fullerene has been functionalized with cyanuric Chloride at room temperature by a nitrene mediated [2 + 1] cycloaddition reaction. The adduct after functionalization is inherently in the form of azafulleroid and shows broad UV absorption in the wavelength range of 200–800 nm, as well as photothermal conversion and fluorescence with a high quantum yield. KW - Functionalization of fullerenes KW - XPS KW - NEXAFS PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-387076 DO - https://doi.org/10.1039/c6ra23419d SN - 2046-2069 VL - 6 IS - 114 SP - 112771 EP - 112775 PB - Royal Society of Chemistry (RSC) AN - OPUS4-38707 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mielke, Johannes A1 - Dohányosová, P. A1 - Lopez, S. A1 - Hodoroaba, Vasile-Dan T1 - Electrospray deposition of nanoparticles on TEM grids N2 - The authors have tested the prototype of an electrospray deposition system developed by the company RAMEM under its trademark IONER. To test the prototype and assess its performance, several materials have been sprayed onto TEM grids and the resulting particle distributions were compared to more traditional sample preparation strategies like the “drop on grid” method. Operation parameters such as the sample flow-rate, capillary – substrate distance, electric field strength and sampling period length have been optimized. It was found that the particles deposited by electrospray generally show a much more homogeneous spatial distribution on the substrate and a substantial increase of the number of single particles, which are much better suited to an automatic image evaluation procedure than the agglomerated particles observed otherwise. The applicability of the technique to a broad range of materials is demonstrated by various examples, but also the influence of the substrate, the choice of the particular TEM grid, on the obtained spatial particle distribution is assessed. KW - Electrspray deposition KW - Electron microscopy KW - Nanoparticles KW - Sample preparation PY - 2016 UR - https://www.cambridge.org/core/journals/microscopy-and-microanalysis/article/electrospray-deposition-of-nanoparticles-on-tem-grids/459E634B7F74D474A19E15E69DA82E5D DO - https://doi.org/10.1017/S1431927616010072 SN - 1431-9276 SN - 1435-8115 VL - 22 IS - Suppl 3 SP - 1846 EP - 1847 PB - Cambridge AN - OPUS4-38436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mielke, Johannes T1 - Evaluation of particle sizing techniques for the implementation of the EC definition of a nanomaterial N2 - What is a nanomaterial? Beyond a pure academic interest, this question has substantial im-plications for consumer protection and regulatory purposes. The European Commission has recommended a definition of nanomaterial (2011/696/EU), which states that a given material is considered a nanomaterial if more than 50 % of the particles in the number size distribution have a smallest dimension between 1 and 100 nm. Although several well established particle sizing techniques exist, the implementation of this definition for any particulate material remains a metrological challenge. The European research project NanoDefine (http://www.nanodefine.eu) has the aim of pro-viding help for the implementation of the definition. One central task is the performance evaluation of the available particle sizing techniques. For this purpose, a wide variety of real world materials has been selected. All available sizing techniques, including imaging, mobility-based and static scattering techniques, independent whether being counting, fractionating, spectroscopic or integrally sizing, will be applied to all of the projects materials to test the techniques performance and to establish their ranges of applicability. Because most of the techniques do not measure in number metrics as required in the nanomaterial definition, the quality of the conversion to the number based particle size distribution is assessed as well. Special care is taken on suitable sample preparation procedures as one of the most chal-lenging issues towards reaching a highly accurate result. Within this contribution, first results of the performance testing of state of the art characterisation techniques on the unique set of NanoDefine real world materials are going to be presented. From these results, first conclu-sions about the material dependent ranges of applicability for the considered particle sizing techniques can be drawn. The technique specific advantages and shortcomings with respect to the application of the EC definition as well as the analytical challenges encountered will be highlighted. Acknowledgements: The research leading to these results has received funding from the European Community's Seventh Framework Programme (FP7/2007-2013) under grant agreement n° 604347. T2 - PARTEC CY - Nürnberg, Germany DA - 19.04.2016 KW - Nanomaterial PY - 2016 AN - OPUS4-35802 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Procop, Mathias A1 - Hodoroaba, Vasile-Dan A1 - Terborg, R. A1 - Berger, D. T1 - Determination of the Effective Detector Area of an Energy-Dispersive X-Ray Spectrometer at the Scanning Electron Microscope Using Experimental and Theoretical X-Ray Emission Yields N2 - A method is proposed to determine the effective detector area for energy-dispersive X-ray spectrometers (EDS). Nowadays, detectors are available for a wide range of nominal areas ranging from 10 up to 150mm2. However, it remains in most cases unknown whether this nominal area coincides with the “net active sensor area” that should be given according to the related standard ISO 15632, or with any other area of the detector device. Moreover, the specific geometry of EDS installation may further reduce a given detector area. The proposed method can be applied to most scanning electron microscope/EDS configurations. The basic idea consists in a comparison of the measured count rate with the count rate resulting from known X-ray yields of copper, titanium, or silicon. The method was successfully tested on three detectors with known effective area and applied further to seven spectrometers from different manufacturers. In most cases the method gave an effective area smaller than the area given in the detector description. KW - Energy-dispersive X-ray spectrometer (EDS) KW - EDX KW - Effective area KW - X-ray emission yield KW - Geometrical collection efficiency PY - 2016 UR - https://www.cambridge.org/core/journals/microscopy-and-microanalysis/article/div-classtitledetermination-of-the-effective-detector-area-of-an-energy-dispersive-x-ray-spectrometer-at-the-scanning-electron-microscope-using-experimental-and-theoretical-x-ray-emission-yieldsdiv/E15B2E67C349201CF323E778EB9C6D94 DO - https://doi.org/10.1017/S1431927616011788 VL - 22 IS - 6 SP - 1360 EP - 1368 PB - Cambridge University Press CY - New York, NY, USA AN - OPUS4-38858 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Can today’s methods afford to easily and reliably classify nanomaterials? N2 - In the contribution the NanoDefine sizing techniques are discussed after their systematic evaluation on NanoDefine materials. The results of the comparative study BET versus electron microscopy are also discussed. Furthermore, recommendations for application of the gained knowledge are given. T2 - NanoDefine Workshop Analytical Challenges and Industry Needs CY - Frankfurt, Germany DA - 08.02.2016 KW - Nanomaterial PY - 2016 AN - OPUS4-35924 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Method evaluation and selection N2 - In this contribution the particle sizing techniques evaluated in NanoDefine are presented together with recommendations for their application/implementation on real-world materials. The experimental evaluation is discussed based on examples on NanoDefine materials. A systematic study on volume specific surface area as derived from BET measurements versus electron microscopy on powdered materials is also presented. T2 - NanoDefine NSC Synergy workshop CY - Brussels, Belgium DA - 02.02.2016 KW - nanomaterial PY - 2016 AN - OPUS4-35923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - From k-values to elemental composition by EMPA (EDX & WDX) N2 - k-values (k-ratio, K-value) is defined as ratio of the X-ray photon intensity I measured for a particular characteristic peak from the unknown sample to the value measured for the same X-ray peak from a reference material of known composition under identical conditions of beam energy, spectrometer efficiency and electron dose. T2 - CCQM - Surface and Micro/Nano Analysis Working Group (SAWG) Meeting for 2016 CY - Paris, France DA - 19.04.2016 KW - k-values KW - EPMA KW - EDX KW - WDX PY - 2016 AN - OPUS4-35794 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Proposal of an inter-laboratory comparison on shape of bipyramidal TiO2 nanoparticles by TEM N2 - A proposal of an inter-laboratory study (ILC) on determination of size and shape distribution of TiO2 nanoparticles (NPs) by transmission electron microscopy is presented. The anatase NPs synthesized in a controllable fashion within the EU/FP7 project SETNanoMetro can be considered as shape-defined (bipyramidal) and are offered to complete the list of case studies already in progress within ISO/TC229/JWG2. The main points of the measurement procedure are presented as well as a proposed procedure to evaluate the size and shape according to the standard operation procedure already developed within SETNanoMetro is discussed. Potential ILC participants and a plan with next step to be carried out are proposed. T2 - Joint Meeting IEC TC 113 'Nanotechnology for electrotechnical products and systems' and ISO/TC229/JWG2 'Nanotechnologies'/'Measurement and characterization' CY - Lowell, MA, USA DA - 09.05.2016 KW - Nanoparticles KW - TiO2 KW - TEM KW - Shape KW - Inter-laboratory comparison KW - ISO PY - 2016 AN - OPUS4-38900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mielke, Johannes A1 - Babick, F. A1 - Uusimäki, T. A1 - Müller, P. A1 - Verleysen, E. A1 - Hodoroaba, Vasile-Dan T1 - Evaluation of electron microscopy techniques for the purpose of classification of nanomaterials N2 - Electron microscopy techniques such as TEM, STEM, SEM or TSEM (transmission in SEM) are capable of assessing the size of individual nanoparticles accurately. Nevertheless, the challenging aspect is sample preparation from powder or liquid form on the substrate, so that a homogeneous distribution of well-separated (deagglomerated) particles is attained. The systematic study in this work shows examples where the extraction of the critical, smallest particle dimension - as the decisive particle parameter for the classification as a NM - is possible by analysing the sample after ist simple, dry preparation. The consequences of additional typical issues like loss of information due to screening of smaller particles by larger ones or the (in)ability to access the constituent particles in aggregates are discussed. KW - Nanomaterial KW - Electron microscopy KW - Particle size distribution KW - Classification PY - 2016 UR - https://www.cambridge.org/core/journals/microscopy-and-microanalysis/article/evaluation-of-electron-microscopy-techniques-for-the-purpose-of-classification-of-nanomaterials/0B66A25EA7F7A5A3622C02A359C8304F DO - https://doi.org/10.1017/S1431927616005523 SN - 1431-9276 SN - 1435-8115 VL - 22 IS - Suppl. 3 SP - 936 EP - 937 PB - Cambridge AN - OPUS4-38445 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kim, K. J. A1 - Kim, A. S. A1 - Jang, J. S. A1 - Suh, J. K. A1 - Wirth, Thomas A1 - Hodoroaba, Vasile-Dan A1 - Unger, Wolfgang A1 - Araujo, J. R. A1 - Archanjo, B. S. A1 - Galhardo, C. E. A1 - Damasceno, J. A1 - Achete, C. A. A1 - Wang, H. A1 - Wang, M. A1 - Bennett, J. A1 - Simons, D. A1 - Kurokawa, A. A1 - Terauchi, S. A1 - Fujimoto, T. A1 - Streeck, C. A1 - Beckhoff, B. A1 - Spencer, S. A1 - Shard, A. T1 - Measurement of mole fractions of Cu, In, Ga and Se in Cu(In,Ga)Se2 films N2 - CCQM key comparison K-129 for the quantitative analysis of Cu(In,Ga)Se2 (CIGS) films has been performed by the Surface Analysis Working Group (SAWG) of the Consultative Committee for Amount of Substance (CCQM). The objective of this key comparison is to compare the equivalency of the National Metrology Institutes (NMIs) and Designated Institutes (DIs) for the measurement of mole fractions of Cu, In, Ga and Se in a thin CIGS film. The measurand of this key comparison is the average mole fractions of Cu, In, Ga and Se of a test CIGS alloy film in the unit of mole fraction (mol/mol). Mole fraction with the metrological unit of mol/mol can be practically converted to atomic fraction with the unit of at%. In this key comparison, a CIGS film with certified mole fractions was supplied as a reference specimen to determine the relative sensitivity factors (RSFs) of Cu, In, Ga and Se. The mole fractions of the reference specimen were certified by isotope dilution - inductively coupled plasma/mass spectrometry (ID-ICP/MS) and are traceable to the SI. A total number counting (TNC) method was recommended as a method to determine the signal intensities of the constituent elements acquired in the depth profiles by Secondary Ion Mass Spectrometry (SIMS), X-ray Photoelectron Spectroscopy (XPS) and Auger Electron Spectroscopy (AES). Seven NMIs and one DI participated in this key comparison. The mole fractions of the CIGS films were measured by depth profiling based-SIMS, AES and XPS. The mole fractions were also measured by non-destructive X-Ray Fluorescence (XRF) Analysis and Electron Probe Micro Analysis (EPMA) with Energy Dispersive X-ray Spectrometry (EDX). In this key comparison, the average degrees of equivalence uncertainties for Cu, In, Ga and Se are 0.0093 mol/mol, 0.0123 mol/mol, 0.0047 mol/mol and 0.0228 mol/mol, respectively. These values are much smaller than that of Fe in a Fe-Ni alloy film in CCQM K-67 (0.0330 mol/mol). This means that the quantification of multi-element alloy films is possible by depth profiling analysis using the TNC method. KW - CIGS KW - Key comparison KW - CCQM KW - SIMS KW - XPS KW - AES KW - XRF KW - EPMA PY - 2016 UR - http://iopscience.iop.org/article/10.1088/0026-1394/53/1A/08011 DO - https://doi.org/10.1088/0026-1394/53/1A/08011 SN - 0026-1394 SN - 1681-7575 VL - 53, Technical Supplement SP - Article 08011, 1 EP - 19 PB - IOP Publishing AN - OPUS4-38110 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nadejde, C. A1 - Neamtu, M. A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Ababei, G. A1 - Panne, Ulrich T1 - Hybrid iron-based core-shell magnetic catalysts for fast degradation of bisphenol A in aqueous systems N2 - Three types of hybrid modified magnetite (Fe₃O₄) nanoparticles, functionalized with either chitosan, chitosan/iron (II) oxalate or chitosan/iron (III) citrate, were synthesized by chemical precipitation method. The obtained nanomaterials were characterized by energy dispersive X-ray spectroscopy, X-ray diffraction, Brunauer–Emmett–Teller analysis, scanning and Transmission electron microscopy, Fourier transform infrared spectroscopy and vibrating sample magnetometry. The prepared composites were further tested as magnetic catalysts for the removal of bisphenol A (BPA) in aqueous media. The kinetic Degradation experiments were performed at laboratory scale, while the best operational parameters for all three materials were established: 1.00 g L⁻¹ of catalyst, 10 mmol L⁻¹ H₂O₂, under simulated solar light irradiation. After 15 min of UVA irradiation under the experimental conditions mentioned above, it was possible to decompose up to 99% of the micropollutant over all catalysts. Fe₃O₄/chitosan/iron oxalate catalyst showed the highest and fastest catalytic activity in BPA removal. Catalytic wet peroxide oxidation of non-biodegradable micropollutants on such iron-based hybrid nanoparticles can be a suitable pre-treatment method for wastewater decontamination, as an environment-friendly simplified Approach for water clean-up. KW - Katalysator KW - Bisphenol A KW - Nano KW - Fenton KW - Magnetische Nanopartikel PY - 2016 DO - https://doi.org/10.1016/j.cej.2016.05.090 SN - 1385-8947 VL - 302 SP - 587 EP - 594 PB - Elsevier CY - Amsterdam AN - OPUS4-37126 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Avishai, N. A1 - Avishai, A. A1 - Hodoroaba, Vasile-Dan T1 - What is the effective geometrical collection efficiency of your XEDS detector? Routine procedure applied in a SEM laboratory N2 - In this contribution, two large-area EDS detectors were tested according to the procedure proposed by Procop et al. (2015). In a first step, the optimal working distance (WD) in the two different SEM chambers was determined by moving the sample stage in the Z direction and monitoring the count rates at a magnification of 10,000 and a field of view of 25.6 µm. The WD at which the highest intensity was measured was selected as the optimal position, corresponding to the crossover between the EDS detector optical axis and electron beam optical axis. Next the Cu Kα peak was measured at different relative EDS positions while it was partially removed from the fully inserted position. The spectrum at each location was collected for 10 sec using the highest pulse rate and intermediate current to minimize pile up effects. The ‘inverse squared normalized intensities vs. relative EDS position’ used to extract the true detector – specimen distance shows a non-linear relationship even at the minimal relative positions, which indicates shadowing due to obstruction or use of an unsuitable and/or off-centered collimator. The normalized count rates measured as a function of the EDS distances, results in a too low GCE (too low true solid angles) for both tested detectors. The source of losses of signal was shadowing caused by collimators. T2 - Microscopy & Microanalysis 2016 Meeting CY - Columbus, Ohio, USA DA - 24.07.2016 KW - EDS KW - Solid angle KW - Net effective sensor area KW - X-ray yields PY - 2016 AN - OPUS4-36982 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Nanoparticles and films characterization: Electron microscopy and related techniques N2 - Scanning Electron Microscopy (SEM) represents the mostly widespread method available in analytical laboratories dedicated to the characterization of physical properties such as morphology of various solid materials from ‘micro-’ down to the nanometre scale. The use of secondary electrons excited by a sharply, nm-focussed primary electron beam enables at any modern SEM to image objects with high in-depth and lateral sensitivity, i.e. with high spatial resolution. Hence, e. g. nanoparticles (NPs) are able to be easily characterized with respect to their individual size and shape, but also to the morphology of their surface. By preparing the nano-objects on thin membranes as electron transparent samples it is possible to perform electron microscopy in the transmission mode (TEM and TSEM). The corresponding transmission (i.e. mass-thickness) contrast reveals in-depth information, but is also well suited for dimensional measurements in the 2D projection image. Both the surface sensitive mode and the transmission one are meanwhile available at any modern SEM. If an X-ray spectrometer is attached to an electron microscope, it is possible to analyse the characteristic X-rays induced by electron bombardment. Most electron microscopes have attached an energy dispersive X-ray spectrometer (EDX) so that EDX elemental maps can be carried out. Recent technological developments of high throughput EDS detectors and their advantages regarding high-resolution X-ray analysis down to the nm range are reviewed. High-resolution micrographs (SEM, TSEM, TEM) and corresponding X-ray elemental maps on various representative nanoparticles, but also layered samples prepared in cross-section, will be presented and discussed. The importance of selecting the best suited analysis conditions will be highlighted. Also other, often challenging, topics such as sample preparation and image data processing will be critically addressed by practical examples. Further analytical techniques able to be employed at an electron microscope, like cathodoluminescence (CL) or micro-X-ray fluorescence (µXRF) will be briefly surveyed. T2 - Nanoscience Meets Metrology - Synthesis, Characterization, Testing and Applications of Validated Nanoparticles - International Summer School CY - Turin, Italy DA - 04.09.2016 KW - Nanoparticles KW - Electron microscopy KW - High-resolution KW - Thin films KW - X-ray spectroscopy PY - 2016 UR - http://www.setnanometro.eu/events/ AN - OPUS4-37325 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Rades, Steffi A1 - Salge, T. A1 - Mielke, Johannes A1 - Ortel, Erik A1 - Schmidt, R. T1 - Characterisation of nanoparticles by means of high-resolution SEM/EDS in transmission mode N2 - Advances in scanning electron microscopy (SEM) enable the high-resolution imaging of single nanoparticles (NPs) with sizes well below 10 nm. The SEM analysis in transmission mode (T-SEM) of NPs on thin film supports has many benefits when compared to the analysis of NPs on bulk substrates. The enhanced material (mass – thickness) contrast of the T-SEM imaging mode is well suited for in-depth and, particularly valuable, to very accurate, traceable, lateral dimensional measurements of NPs. Compared to samples prepared on bulk substrates, T-SEM with energy dispersive X-ray spectroscopy (EDS) achieves a drastically improved spatial resolution of the emitted X-rays. The poor signal-to-noise ratio of the X-ray spectra emitted by a single nanoparticle (NP) can be improved by the use of high-sensitivity (high collection solid angle) silicon drift (SDD), energy-dispersive X-ray spectrometers (EDS). The EDS spectral imaging of a single NP with a spatial resolution below 10 nm has become possible. This is demonstrated by means of various examples of nanostructures. Advanced data processing of T-SEM/EDS results sets the stage for the automated classification of NPs by feature analysis. This method combines the detection of morphological structures of interest by image processing of T-SEM micrographs with the chemical classification by EDS. T2 - European Microbeam Analysis Society’s 14th European Workshop on Modern Developments and Applications in Microbeam Analysis (EMAS 2015) CY - Portorož, Slovenia DA - 03.05.2015 KW - High-resolution KW - SEM KW - T-SEM KW - EDX KW - Nanoparticles PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-355628 UR - http://iopscience.iop.org/article/10.1088/1757-899X/109/1/012006 DO - https://doi.org/10.1088/1757-899X/109/1/012006 SN - 1757-899X VL - 109 SP - 012006-1 EP - 012006-12 PB - IOP Publishing Ltd CY - Bristol, UK AN - OPUS4-35562 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Belsey, N. A. A1 - Cant, D. J. H. A1 - Minelli, C. A1 - Araujo, J. R. A1 - Bock, B. A1 - Brüner, P. A1 - Castner, D. G. A1 - Ceccone, G. A1 - Counsell, J. D. P. A1 - Dietrich, Paul M. A1 - Engelhardt, M. H. A1 - Fearn, S. A1 - Galhardo, C. E. A1 - Kalbe, H. A1 - Kim, J. W. A1 - Lartundo-Rojas, L. A1 - Luftman, H. S. A1 - Nunney, T. S. A1 - Pseiner, J. A1 - Smith, E. F. A1 - Spampinato, V. A1 - Sturm, J. M. A1 - Thomas, A. G. A1 - Treacy, J. P. W. A1 - Veith, L. A1 - Wagstaffe, M. A1 - Wang, H. A1 - Wang, M. A1 - Wang, Y.-C. A1 - Werner, W. A1 - Yang, L. A1 - Shard, A. G. T1 - Versailles Project on Advanced Materials and Standards Interlaboratory Study on Measuring the Thickness and Chemistry of Nanoparticle Coatings Using XPS and LEIS N2 - We report the results of a Versailles Project on Advanced Materials and Standards (VAMAS) interlaboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage, or sample preparation resulted in a variability in thickness of 53%. The calculation method chosen by XPS participants contributed a variability of 67%. However, variability of 12% was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors since this contributed a variability of 33%. The results from the LEIS participants were more consistent, with variability of less than 10% in thickness, and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films, and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results. KW - VAMAS KW - Interlaboratory Study KW - Nanoparticle coating KW - XPS KW - LEIS KW - shell thicknss and chemistry PY - 2016 UR - http://pubs.acs.org/doi/pdf/10.1021/acs.jpcc.6b06713 DO - https://doi.org/10.1021/acs.jpcc.6b06713 IS - 120 SP - 24070 EP - 24079 PB - ACS Publications AN - OPUS4-38428 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mieller, Björn A1 - Vogl, Jochen A1 - Noordmann, J. A1 - Kaltenbach, A. A1 - Rienitz, O. T1 - Preparation and characterization of primary magnesium mixtures for the ab initio calibration of absolute magnesium isotope ratio measurements N2 - We report an appropriate preparation of binary isotope calibration mixtures of the three stable isotopes of magnesium to be used in the ab initio calibration of multicollector mass spectrometers (ICPMS and TIMS). For each of the three possible combinations of binary mixtures ("24Mg" + "25Mg", "24Mg" + "26Mg", and "25Mg" + "26Mg"), three individual setups have been prepared under gravimetric control, each of them with an isotope ratio close to unity, and a total magnesium mass fraction close to 20 mg kg-1. The preparation was designed to occur via an intermediate dilution of a parent solution of a highly purified specimen of the isotopically enriched magnesium materials. For the application as calibration mixtures, a complete uncertainty budget was set up, and is presented and discussed in detail, including the aspects that went into the design of the dilution and mixing approach to minimize uncertainty. The principle parameters for the purpose of the later calibration of the mass spectrometers are the absolute masses of isotopically enriched magnesium materials in the primary calibration mixtures. For the first time relative expanded uncertainties U (k = 2) for these masses of ≤0.005% could be achieved for all mixtures. KW - Atomic weight KW - Magnesium KW - Isotope mixture KW - Purity PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-352564 DO - https://doi.org/10.1039/c5ja00284b SN - 0267-9477 SN - 1364-5544 N1 - Geburtsname von Mieller, Björn: Brandt, B. - Birth name of Mieller, Björn: Brandt, B. N1 - Corrigendum: Journal of analytical atomic spectrometry 34 (2019) 2340 VL - 31 IS - 1 SP - 179 EP - 196 PB - Royal Society of Chemistry CY - London AN - OPUS4-35256 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogl, Jochen A1 - Mieller, Björn A1 - Noordmann, J. A1 - Rienitz, O. A1 - Malinovskiy, D. T1 - Characterization of a series of absolute isotope reference materials for magnesium: ab initio calibration of the mass spectrometers, and determination of isotopic compositions and relative atomic weights N2 - For the first time, an ab initio calibration for absolute Mg isotope ratios was carried out, without making any a priori assumptions. All quantities influencing the calibration such as the purity of the enriched isotopes or liquid and solid densities were carefully analysed and their associated uncertainties were considered. A second unique aspect was the preparation of three sets of calibration solutions, which were applied to calibrate three multicollector ICPMS instruments by quantifying the correction factors for instrumental mass discrimination. Those fully calibrated mass spectrometers were then used to determine the absolute Mg isotope ratios in three candidate European Reference Materials (ERM)-AE143, -AE144 and -AE145, with ERM-AE143 becoming the new primary isotopic reference material for absolute isotope ratio and delta measurements. The isotope amount ratios of ERM-AE143 are n(25Mg)/n(24Mg) = 0.126590(20) mol/mol and n(26Mg)/n(24Mg) = 0.139362(43) mol/mol, with the resulting isotope amount fractions of x(24Mg) = 0.789920(46) mol/mol, x(25Mg) = 0.099996(14) mol/ mol and x(26Mg) = 0.110085(28) mol/mol and an atomic weight of Ar(Mg) = 24.305017(73); all uncertainties were stated for k = 2. This isotopic composition is identical within uncertainties to those stated on the NIST SRM 980 certificate. The candidate materials ERM-AE144 and -AE145 are isotopically lighter than ERM-AE143 by 1.6 ‰ and 1.3 ‰, respectively, concerning their n(26Mg)/n(24Mg) ratio. The relative combined standard uncertainties are ≤0.1 ‰ for the isotope ratio n(25Mg)/n(24Mg) and ≤0.15 ‰ for the isotope ratio n(26Mg)/ n(24Mg). In addition to characterizing the new isotopic reference materials, it was demonstrated that commonly used fractionation laws are invalid for correcting Mg isotope ratios in multicollector ICPMS as they result in a bias which is not covered by its associated uncertainty. Depending on their type, fractionation laws create a bias up to several per mil, with the exponential law showing the smallest bias between 0.1 ‰ and 0.7 ‰. KW - isotope reference material KW - absolute measurements KW - mass spectrometry KW - atomic weight KW - magnesium PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-370931 DO - https://doi.org/10.1039/C6JA00013D SN - 0267-9477 N1 - Geburtsname von Mieller, Björn: Brandt, B. - Birth name of Mieller, Björn: Brandt, B. VL - 31 IS - 7 SP - 1440 EP - 1458 PB - Royal Society of Chemistry CY - Cambridge, UK AN - OPUS4-37093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Babick, F. A1 - Mielke, Johannes A1 - Wohlleben, W. A1 - Weigel, St. A1 - Hodoroaba, Vasile-Dan T1 - How reliably can a material be classified as a nanomaterial? Available particle-sizing techniques at work N2 - Currently established and projected regulatory frameworks require the classification of materials (whether nano or non-nano) as specified by respective definitions, most of which are based on the size of the constituent particles. This brings up the question if currently available techniques for particle size determination are capable of reliably classifying materials that potentially fall under these definitions. In this study, a wide variety of characterisation techniques, including counting, fractionating, and spectroscopic techniques, has been applied to the same set of materials under harmonised conditions. The selected materials comprised well-defined Quality control materials (spherical, monodisperse) as well as industrial materials of complex shapes and considerable polydispersity. As a result, each technique could be evaluated with respect to the determination of the number-weighted median size. Recommendations on the most appropriate and efficient use of techniques for different types of material are given. KW - Nanomaterial classification KW - Nanoparticle KW - Number-weighted median size KW - Tiered KW - Particle size analysis KW - Nanometrology KW - Characterisation techniques PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-367922 UR - http://link.springer.com/article/10.1007/s11051-016-3461-7 DO - https://doi.org/10.1007/s11051-016-3461-7 SN - 1388-0764 SN - 1572-896X VL - 18 IS - 6 SP - Article 158, 1 EP - 40 PB - Springer AN - OPUS4-36792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Anja T1 - Quantitative chemichal depth-profiling by synchrotron-radiation-XPS N2 - Synchrotron-radiation enables the adjustment of the XPS information depth and, thus, the visualization of depth profiles of the elemental composition within the first 10 nm of a surface. This project deals with the analysis of core-shell nanoparticles. It constitutes first steps towards a valid methodology for studying the surface chemistry of nanoparticles in a quantitative and accurate manner. T2 - Eighth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 07.12.2016 KW - XPS KW - Synchrotron KW - Depth-profiling KW - Core@Shell Nanoparticles PY - 2016 N1 - Geburtsname von Müller, Anja: Hermanns, A. - Birth name of Müller, Anja: Hermanns, A. AN - OPUS4-38782 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ortel, Erik A1 - Häusler, Ines A1 - Österle, Werner A1 - Narbey, S. A1 - Oswald, F. A1 - Andersen, I. H. A1 - Holzweber, Markus A1 - Unger, Wolfgang A1 - Hodoroaba, Vasile-Dan T1 - In-depth structural and chemical characterization of engineered TiO2 films N2 - Analytical routines for a comprehensive in-depth morphological, structural, and chemical characterization of functionalized TiO2 films by using different state-of-the-art analytical techniques are presented and discussed with the main objective to identify potential reference TiO2 coating parameters able to be certified at a later stage. TiO2 films fabricated by two different synthetic procedures as representative for two main large-scale applications were selected: (i) pulsed d.c. magnetron sputtering for photocatalytic applications and (ii) screen printing from preformed anatase nanoparticles. The screen-printed films were further loaded with a sensitizing dye for application as a dye-sensitized solar cell. Film properties such as microstructure and crystallographic texture of pulsed d.c. magnetron sputtering synthesized films were systematically studied by means of scanning nanobeam electron diffraction in a transmission electron microscope and the surface and inner morphology by scanning electron microscopy. The dye distribution over the depth of screen-printed TiO2 layers was analyzed before and after dye-loading by means of energy dispersive X-ray spectroscopy at scanning electronmicroscope, Auger electron spectroscopy and time-of-flight secondary ion mass spectrometry. The long-term goal of the present study is the improvement of quality of the TiO2 film parameters as measured by using different types of reference TiO2 coatings having specific parameters certified. T2 - 16th European Conference on Applications of Surface and Interface Analysis ECASIA'15 CY - Granada, Spain DA - 28.09.2015 KW - Mapping KW - Line scan KW - Depth profiling KW - TiO2 films KW - Crystallinity KW - Ru dye sensitizer PY - 2016 DO - https://doi.org/10.1002/sia.5966 SN - 0142-2421 SN - 1096-9918 VL - 48 SP - 664 EP - 669 PB - John Wiley & Sons, Ltd. AN - OPUS4-36791 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Holzweber, Markus A1 - Unger, Wolfgang A1 - Hodoroaba, Vasile-Dan T1 - Ionic liquids as a reference material candidate for the quick performance check of energy dispersive X-ray spectrometers for the low energy range below 1 keV N2 - Ionic liquids (ILs) are proposed as simple and efficient test materials to evaluate the performance of energy dispersive X-ray spectrometers (EDS) in the low energy range below 1 keV. By only one measurement, C Kα, N Kα, O Kα, and F Kα X-ray lines can be excited. Additionally, the S Kα line at 2.3 keV and, particularly, the S L series at 149 eV complete the picture with X-ray lines offered by the selected ILs. The well-known (certifiable) elemental composition of the ILs selected in the present study can be used to check the accuracy of results produced with the available EDS quantification routines in the low energy range, simultaneously, for several low atomic number elements. A comparison with other reference materials in use for testing the performance of EDS in the low energy range is included. KW - Ionic liquids KW - EDX KW - CRM KW - Reference material KW - Low energy KW - X-rays PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-369120 DO - https://doi.org/10.1021/acs.analchem.6b01444 SN - 0003-2700 SN - 1520-6882 VL - 88 IS - 14 SP - 6967 EP - 6970 PB - ACS Publications CY - Columbus, Ohio AN - OPUS4-36912 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Babick, F. A1 - Mielke, Johannes A1 - Hodoroaba, Vasile-Dan A1 - Weigel, St. A1 - Wohlleben, W. T1 - Critical review manuscript with real-world performance data for counting, ensemble and separating methods including in-build mathematical conversion to number distributions submitted for publication N2 - The content of the paper is the assessment of the performance of (conventional) measurement techniques (MTs)with respect to the classification of disperse materials according to the EC recommendation for a definition of nanomaterial. This performance essentially refers to the accurate assessment of the number weighted median of (the constituent) particles. All data and conclusions are based on the analytical study conducted as real-world performance testing. It comprised different types of MTs (imaging, counting, fractionating, spectroscopic and integral) as well as different types of materials. Beside reference materials with well-defined size distribution the study also included several commercial powders (variation of particle composition, morphology, coating, size range and polydispersity). In order to ensure comparability of measurement results, the participants were guided to use uniform protocols in sample preparation, conducting measurements, data analysis and in reporting results. Corresponding documents have been made public, in order to support the reviewing process of the paper, respectively to ensure the reproducibility of data by other users under the same conditions. The scientific paper relies on a comprehensive set of revised measurement data reported in uniform templates, completely describes the experimental procedures and discusses the MTs’ performance for selected materials in detail. Even more, the study is summarised and evaluated, which leads to recommendations for the use of MTs within a tiered approach of NM characterisation. In addition, the paper critically examines the factors that may affect the outcome of such a comparison among different MTs. KW - Nanomaterial KW - Measurement techniques KW - EC definition of nanomaterial KW - Nanoparticles PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-389646 UR - http://www.nanodefine.eu/index.php/downloads/nanodefine-technical-reports UR - http://www.nanodefine.eu/publications/reports/NanoDefine_TechnicalReport_D3.3.pdf SP - D3.3, 1 EP - 72 PB - The NanoDefine Consortium CY - Wageningen, The Netherlands AN - OPUS4-38964 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Léonard, Fabien A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray and new statistical analysis methods N2 - Complex materials (e.g., porous ceramics) need high resolution techniques at multi-scale levels. Microstructure is intimately linked to properties and performance. One technique (or even a few techniques) is not enough. X-ray refraction and CT are very powerful tools. Non-destructive characterisation and quantitative image analysis techniques (2D and 3D) are necessary to understand the anisotropy. T2 - 40th International Conference and Expo on Advanced Ceramics and Composites ( ICACC) CY - Daytona Beach, USA DA - 24.01.2016 KW - X-ray computed tomography KW - X-ray refraction KW - Directional interface variance analysis (DIVA) KW - FFT periodogram PY - 2016 AN - OPUS4-41725 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ortel, Erik A1 - Hertwig, Andreas A1 - Berger, D. A1 - Esposito, P. A1 - Rossi, A. M. A1 - Kraehnert, R. A1 - Hodoroaba, Vasile-Dan T1 - New approach on quantification of porosity of thin films via electron-excited X‑ray spectra N2 - One of the crucial characteristics of functionalized thin films is their porosity (i.e., the ratio between the pore volume and the volume of the whole film). Due to the very low amount of material per coated area corresponding to thin films, it is a challenge for analytics to measure the film porosity. In this work, we present an Approach to determine the porosity of thin films by means of electron probe microanalysis (EPMA) either by wavelength-dispersive X-ray spectrometry (WDX) or by energy-dispersive X-ray spectrometry (EDX) with a scanning electron microscope (SEM). The procedure is based on the calculation of the film mass deposition from electron-excited X-ray spectra. The mass deposition is converted into film density by division of measured film thickness. Finally, the film porosity is calculated from the measured film density and the density of bulk, nonporous film material. The general applicability of the procedure to determine the porosity is demonstrated on thin templated mesoporous TiO₂ films, dip-coated on silicon wafer, with controlled porosity in the range of 15 to 50%. The high accuracy of the mass deposition as determined from X-ray spectra was validated with independent methods (ICP-OES and weighing). Furthermore, for the validation of the porosity results, ellipsometry, interference fringes method (IFM), and focused ion beam (FIB) cross sectioning were employed as independent techniques. Hence, the approach proposed in the present study is proven to be suited as a new analytical tool for accurate and relatively fast determination of the porosity of thin films. KW - Porosity KW - X-rays KW - EDX KW - Thin film KW - TiO2 KW - Density KW - Mass deposition KW - STRATAGem PY - 2016 UR - http://pubs.acs.org/doi/abs/10.1021/acs.analchem.6b00847 DO - https://doi.org/10.1021/acs.analchem.6b00847 VL - 88 IS - 14 SP - 7083 EP - 7090 PB - ACS Publications CY - 1155 Sixteenth Street N.W., Washington, DC 20036 AN - OPUS4-36911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mielke, Johannes A1 - Babick, F. A1 - Uusimäki, T. A1 - Müller, P. A1 - Verleysen, E. A1 - Hodoroaba, Vasile-Dan T1 - Evaluation of electron microscopy techniques for the purpose of classification of nanomaterials N2 - One current and much-debated topic in the characterization of nanomaterials (NM) is the implementation of the recently introduced recommendation on a definition of a nanomaterial by the European Commission. All currently available sizing techniques able to address nanoparticles were systematically evaluated. It was demonstrated that particle sizing techniques like: analytical centrifugation, particle tracking analysis, single-particle inductively coupled plasma mass-spectrometry, differential electrical mobility analysis, dynamic light scattering, small angle X-ray scattering, ultrasonic attenuation spectrometry, but also gas Adsorption analysis based on the BET-method can be applied for a screening classification. However, the quality of the results depends on the individual material to be classified. For well-dispersed, nearly spherical (nano)particles most of the sizing techniques can be applied in a quick and reliable way. In contrast, the classification of most real-world materials is a challenging task, mainly due to non-spherical particle shape, large polydispersity or strong agglomeration/ aggregation of the particles. In the present study it was shown that these issues can be resolved in most cases by electron microscopy as a confirmatory classification technique. Electron microscopy techniques such as TEM, STEM, SEM or TSEM transmission in SEM) are capable of assessing the size of individual nanoparticles accurately (see Figures 1 and 2). Nevertheless the challenging aspect is sample preparation from powder or liquid form on the substrate, so that a homogeneous distribution of well-separated (deagglomerated) particles is attained. The systematic study in this work shows examples where the extraction of the critical, smallest particle dimension - as the decisive particle parameter for the classification as a NM - is possible by analysing the sample after its simple, dry preparation. The consequences of additional typical issues like loss of information due to Screening of smaller particles by larger ones or the (in)ability to access the constituent particles in aggregates are discussed. T2 - European Microscopy Congress emc 2016 CY - Lyon, France DA - 28.08.2016 KW - Nanomaterial classification KW - Nanoparticles KW - Electron microscopy PY - 2016 SN - 9783527808465 DO - https://doi.org/10.1002/9783527808465.EMC2016.5767 SP - 13 EP - 14 PB - Wiley-VCH AN - OPUS4-44087 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Avishai, N. A1 - Avishai, A. A1 - Hodoroaba, Vasile-Dan T1 - What is the effective geometrical collection efficiency of your XEDS detector? A routine procedure applied in a SEM laboratory. N2 - In this contribution, two large-area EDS detectors were tested according to the procedure proposed recently by Procop et al. In a first step, the optimal working distance (WD) in the two different SEM chambers was determined by moving the sample stage in the Z direction and monitoring the count rates from a field of view of 25.6 μm. The WD at which the highest intensity was measured was selected as the optimal position. Next the Cu Kα peak was measured at different relative EDS positions while it was partially removed from the fully inserted position. The spectrum at each location was collected for 10 sec using the highest pulse rate and intermediate current (2.3 nA) to minimize pile up effects (13% dead time). The ‘inverse squared normalized intensities vs. relative EDS position’ used to extract the true detector – specimen distance shows a non-linear relationship even at the minimal relative positions, which indicates shadowing due to obstruction or use of an unsuitable and/or off-centered collimator. The normalized count rates measured as a function of the EDS distances, results in a too low GCE (too low true solid angles) for both tested detectors. The search for sources of losses of signal due to possible shadowing effects is in progress. KW - EDS Geometrical Detection Efficiency KW - EDS Solid Angle KW - EDS net active sensor area KW - EDS detector PY - 2016 UR - https://www.cambridge.org/core/journals/microscopy-and-microanalysis/article/what-is-the-effective-geometrical-collection-efficiency-of-your-xeds-detector-a-routine-procedure-applied-in-a-sem-laboratory/40A1A25C97916CA4D9FA365249CFC36C DO - https://doi.org/10.1017/S1431927616002919 SN - 1431-9276 SN - 1435-8115 VL - 22 IS - Suppl. 3 SP - 412 EP - 413 PB - Cambridge AN - OPUS4-38446 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bruno, Giovanni A1 - Cabeza, Sandra A1 - Mishurova, Tatiana A1 - Garcés, G. A1 - Requena, G. T1 - The role of reinforcement orientation on the damage evolution of AlSi12CuMgNi +15% Al2O3 under compression N2 - Internal damage of an AlSi12CuMgNi alloy reinforced with planar randomshort fibres has been investigated after compression. This damage strongly influences the load partition between matrix and reinforcement. For fibres perpendicular to the applied load, breakage and interconnected cracks appear in significantly higher volume fraction than with fibres parallel to load. KW - Metal Matrix Composites KW - Damage KW - Load partition KW - Synchrotron CT KW - Neutron diffraction PY - 2016 VL - 122 SP - 115 EP - 118 PB - Elsevier Ltd. AN - OPUS4-37975 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni T1 - Was kann die Neutronenbeugung für die ZfP tun? N2 - Neutronenbeugung hat verschiedenste Anwendungen, die auf die eigenartigen physikalischen Eigenschaften der Neutronen berühen. Während die Beugungstechniken wie z.B. die klassische Pulverbeugung, die Kleinwinkelstreuung und die Texturanalyse besonders für die Materialcharakterisierung nutzbar sind, setzt sich die Neutronenbeugung als zerstörungsfreies Verfahren für Eigenspannungsanalyse extrem relevant ein. Allerdings sind nur wenig die Leute, die die Neutronenbeugung in der ZfP Community benutzen. Dieser Vortrag hat das Ziel die Interesse an der Nutzung von einem solchen Grossgerätwerkzeug aufzuwecken und ein Paar impactvolle Anwendungsbeispiele einiger Techniken zu zeigen. Die Bestimmung mikroskopischer mechanischen Eigenschaften von Kompositen (MMC oder CMC), sowie der Mapping von Eigenspannungsfelder in Komponenten werden bearbeitet. Es wird gezeigt, dass Neutronenbeugung grundsätzlich eine zerstörungsfreie Methode für beide die Materialcharakterisierung und die Komponentenintegrität ist, die hohes Potentiell hat, zum Verfahrensportfolio der zerstörungsfreier Prüfung zu gehören. T2 - 381. Sitzung des Arbeitskreises Berlin der DGZfP CY - BAM, Berlin, Deutschland DA - 01.11.2016 KW - Neutronenbeugung KW - Eigenspannungen KW - Kompositen KW - Legierungen KW - Schweißnähte KW - TF Material PY - 2016 AN - OPUS4-38313 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Unger, Wolfgang T1 - NEXAFS and XPS analysis of functionalized graphene surfaces for bio applications N2 - Graphene prepared from Graphene oxide (GO) is used as a platform for functional 2D nanomaterials with diverse applications ranging from bios ensors to antimicrobial surfaces. C and N K-edge NEXAFS and XPS spectroscopies at BESSY’s HE-SGM beamline have been used to prove and control covalent functionalization of graphenic materials at ambient conditions for the synthesis of functional 2D-surfaces. T2 - 8th Jouint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 7.12.2016 KW - XPS KW - NEXAFS KW - Graphene PY - 2016 AN - OPUS4-38683 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Saywell, A. A1 - Bakker, A. A1 - Mielke, Johannes A1 - Kumagai, T. A1 - Wolf, M. A1 - García-López, V. A1 - Chiang, P.-T. A1 - Tour, J. M. A1 - Grill, L. T1 - Light-Induced Translation of Motorized Molecules on a Surface N2 - Molecular machines are a key component in the vision of molecular nanotechnology and have the potential to transport molecular species and cargo on surfaces. The motion of such machines should be triggered remotely, ultimately allowing a large number of molecules to be propelled by a single source, with light being an attractive stimulus. Here, we report upon the photoinduced translation of molecular machines across a surface by characterizing single molecules before and after illumination. Illumination of molecules containing a motor unit results in an enhancement in the diffusion of the molecules. The effect vanishes if an incompatible photon energy is used or if the motor unit is removed from the molecule, revealing that the enhanced motion is due to the presence of the wavelength-sensitive motor in each molecule. KW - Diffusion KW - Molecular devices KW - Molecular motor KW - Scanning probe microscopy KW - Photoexcitation KW - Photochemistry KW - Molecular machines PY - 2016 UR - http://pubs.acs.org/doi/abs/10.1021/acsnano.6b05650 DO - https://doi.org/10.1021/acsnano.6b05650 VL - 10 IS - 12 SP - 10945 EP - 10952 PB - ACS Publications AN - OPUS4-39095 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mielke, Johannes A1 - Martınez-Blanco, J. A1 - Peters, M. V. A1 - Hecht, S. A1 - Grill, L. T1 - Observing single-atom diffusion at a molecule-metal interface N2 - The dynamics at the interface between a close-packed porphyrin monolayer and Au(111) is investigated by time-dependent scanning tunneling microscopy, detecting the motion of single-interface adatoms in real space. Imaging sequences reveal predominant switching of the molecular appearance in adjacent molecules, pointing to a spatial correlation that is consistent with adatom diffusion from one molecule to the next. In some cases, the number of switching molecules is drastically increased, indicating collective switching events. In addition to the thermally induced motion of adatoms at the interface, also voltage pulses from the microscope tip can induce the process—revealing different yields in agreement with the model of adatom hopping. KW - STM KW - molecular switch KW - single molecule KW - switching dynamics KW - porphyrin KW - Au(111) PY - 2016 UR - http://journals.aps.org/prb/abstract/10.1103/PhysRevB.94.035416 DO - https://doi.org/10.1103/PhysRevB.94.035416 VL - 94 IS - 3 SP - 035416-1 EP - 035416-7 PB - American Physical Society AN - OPUS4-37177 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana T1 - Polymer characterisation by multidimensional techniques with focus on LC - MALDI/ESI-TOF-MS N2 - Since the first LC/ ESI-MS experiment of the Nobel prize winner John B. Fenn in 1984, the coupling of liquid chromatographic to mass spectrometric techniques gained a continuous rapid development. The lecture will give a general survey of different LC separation techniques as size exclusion chromatography (SEC), liquid adsorption chromatography (LAC), liquid chromatography at critical conditions (LCCC) and gradient elution liquid chromatography (GELC) combined with Matrix assisted Laser Desorption Ionization (MALDI) respectively Electrospray Ionization (ESI) Time of Flight (TOF) mass spectrometry. Often the deficiencies of stand-alone methods can be bridged. LC, blind to structural information needs mass spectrometry as one of the most powerful detectors able to give detailed information on e.g. the repeat units, functionalization or copolymer composition of the chromatographic separated constituents. A separation prior to MS reduces the polydispersity which is one of the reasons for failing of MS. Also problems with different ionization probabilities in complex mixtures can partly be overcame. On the basis of different examples on- and offline coupling principles will be compared and the pros and cons of both mass spectrometric techniques will be discussed. Recently, MALDI imaging techniques in coupling with chromatography have become interesting e.g. for visualization of copolymer composition. T2 - International Symposium GPC/SEC and Related Techniques CY - Amsterdam, The Netherlands DA - 26.09.2016 KW - Polymers KW - Liquid chromatography KW - MALDI-TOF-MS KW - ESI-TOF-MS PY - 2016 AN - OPUS4-37629 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -