TY - CONF A1 - Hutchinson, R. A1 - Wilkins, J. A1 - Summerfield, L. A1 - O’Connor, C. A1 - McLachlin, K. A1 - Jakubowski, Norbert A1 - Traub, Heike A1 - Esteban-Fernández, Diego T1 - Performance and data from an elemental microscope - The NWR image N2 - The NWRimage system is the first elemental imaging-specific laser ablation instrument, offering breakthrough sub-micron spatial resolution and ultra-fast signal response for high throughput rates. Laser ablation (LA) systems are used in conjunction with Inductively Coupled Plasma Mass Spectrometry (ICP-MS) systems to detect and analyze tiny amounts of material. As ICP-MS systems have become more sensitive, a need has emerged for LA imaging tools with < 1 micron spatial resolution - a capability not previously available on the market. The NWRimage is provided with a carefully designed aerosol path from point of ablation to injection into the ICP itself. This aerosol path combined with a novel Dual Concentric Injector (DCI) ICP torch, yields < 50ms signal response to accelerate the speed of analysis and enabling enhanced sample throughput. The LA system is used for bio imaging of single cells and medical tissue samples. T2 - Winter Conference on Plasma Spectrochemistry 2016 CY - Tucson, Arizona, USA DA - 11.01.2016 KW - Laser ablation KW - Bio imaging PY - 2016 AN - OPUS4-36513 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Geißler, Daniel A1 - Hildebrandt, N. T1 - Recent developments in Förster resonance energy transfer (FRET) diagnostics using quantum dots N2 - The exceptional photophysical properties and the nanometric dimensions of colloidal semiconductor quantum dots (QD) have strongly attracted the bioanalytical community over the last approximately 20 y. In particular, the integration of QDs in the analysis of biological components and interactions, and the related diagnostics using Förster resonance energy transfer (FRET), have allowed researchers to significantly improve and diversify fluorescence-based biosensing. In this TRENDS article, we review some recent developments in QD-FRET biosensing that have implemented this technology in electronic consumer products, multiplexed analysis, and detection without light excitation for diagnostic applications. In selected examples of smartphone-based imaging, single- and multistep FRET, steady-state and time-resolved spectroscopy, and bio/chemiluminescence detection of QDs used as both FRET donors and acceptors, we highlight the advantages of QD-based FRET biosensing for multiplexed and sensitive diagnostics. KW - Fluorescence spectroscopy and imaging KW - Multiplexing immunoassay KW - Nanoparticle KW - DNA/RNA KW - BRET/CRET PY - 2016 DO - https://doi.org/10.1007/s00216-016-9434-y SN - 1618-2642 SN - 1618-2650 VL - 408 IS - 17 SP - 4475 EP - 4483 PB - Springer-Verlag CY - Berlin, Heidelberg AN - OPUS4-36546 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike A1 - Drescher, Daniela A1 - Büchner, T. A1 - Zeise, Ingrid A1 - Kneipp, Janina A1 - Jakubowski, Norbert T1 - Studying cellular uptake and processing of nanoparticles by LA-ICP-MS N2 - In recent years, elemental imaging of biological samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining in importance. Latest improvements regarding spatial resolution (down to 1 µm) and washout time make LA-ICP-MS particularly interesting for single cell analysis. Many current nanomaterials can serve as contrast agents in cellular or tissue imaging, drug delivery vehicles or therapeutics, whereas others can cause toxic effects. In order to evaluate nano-bio interactions, the number of nanoparticles (NPs) inside cells as well as their localisation within cellular substructures is of particular interest. LA-ICP-MS was used to study the NP pathway from uptake, via intracellular processing up to cell division. Fibroblast cells were incubated with different metallic NPs under varying experimental conditions. For LA analysis the cells were fixed with formaldehyde and dried. Our results show that LA-ICP-MS is able to localise NP aggregates within cellular substructures. The NPs accumulate in the perinuclear region in the course of intracellular processing, e.g. multivesicular fusion and endosomal maturation, but do not enter the nucleus [1, 2]. A strong dependence of NP uptake on concentration and incubation time was found. Additionally, the number of NPs internalized by individual cells was determined and variations within the cell population became visible. A new laser ablation system providing a short washout time (50 ms) together with small spot sizes (< 4 µm) and high repetition rates allows high spatial resolution applications. First results of cell imaging will be shown. The findings demonstrate the potential of LA-ICP-MS enabling insight into NP uptake and intracellular distribution dependent on experimental parameters. T2 - 8th Nordic Conference on Plasma Spectrochemistry CY - Loen, Norway DA - 05.06.2016 KW - Imaging KW - LA-ICP-MS KW - Cell KW - Nanoparticles PY - 2016 AN - OPUS4-36500 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, Cassian A1 - Grothe, Sven A1 - Wilsch, Gerd T1 - Cluster algorithm for the evaluation of heterogeneous materials by LIBS N2 - The laser-induced breakdown spectroscopy (LIBS) is a fast method to provide multi-elemental analysis of any sample. At the Federal Institute for Materials Research and Testing (BAM) the LIBS technique is applied on building materials to measure ingress profiles of harmful species like chloride and alkalis. The ingress depth and the quantitative amount is important for the evaluation of the potential for damage processes like the alkali-silica reaction or chloride-induced corrosion. Concrete as an example is a highly heterogeneous material with 1/7 cement (major component CaO) and 6/7 aggregates (SiO2) with different grain sizes. Due to a scanning procedure a two dimensional element distribution of a concrete surface can be measured. In order to have an automated Separation method to evaluate heterogeneous materials, different cluster algorithm have been tested. Best results have been achieved with the Expectation-Maximization-Algorithm (EM-Algorithm). T2 - Chemometrics in analytical chemistry CY - Barcelona, Spain DA - 06.06.2016 KW - LIBS KW - Concrete KW - Multivariate analysis PY - 2016 AN - OPUS4-36471 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Coping with the EU Nano-definition: abilities and limitations of particle sizing with SAXS N2 - Excelling in brevity but lacking in applicability, the 2011 EU nanomaterial definition has become a source of anguish for scientists and industry alike. Repeated pleas and discussions with our own envoy have demonstrated the strength of their resolve: this definition is unlikely to change. Manufacturers of many materials (cosmetics, pigments, foodstuffs, etc.) will have to characterise and label all their products accordingly, a task still impossible for lack of a clear metrological approach towards this goal. Therefore, the onus has fallen on the scientists to come up with a practicable measurement technique allowing inexpensive classification covering large swathes of the material landscape. Small-angle X-ray Scattering (SAXS) probes the size range in question, and can - with due care - deliver a bulk-averaged volume-weighted size distribution. Like any other real-world measurement method, however, it is not (and can never be) a universal solution. This presentation will clarify the SAXS technique, provide several application examples for nanomaterial characterisation, and will detail the limitations and pitfalls that accompany its abilities. At the end of this presentation, you will have the information to judge whether the technique is amenable to your materials or not. T2 - 2016 TechConnect World Innovation Conference CY - National Harbor, MD, USA DA - 23.05.2016 KW - SAXS KW - presentation KW - EU KW - Nanomaterial PY - 2016 AN - OPUS4-36489 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Asadujjaman, Asad A1 - Bertin, Annabelle T1 - Aggregation behavior of UCST-Type Poly(Acrylamide-co-Acrylonitrile) copolymer N2 - Thermoresponsive polymers have shown great potential in applications such as bioseparation, drug delivery and diagnostic. Only few thermoresponsive polymers that present an upper critical solution temperature (UCST) in a relevant temperature range, i.e. phase separate from solution upon cooling, have been reported so far. Moreover, the most studied UCST type polymers namely polybetaines are difficult to use under physiological conditions, which significantly restricts their potential applications. Therefore, UCST polymers with sharp and robust phase transition in physiological conditions (in the presence of salts, ions etc.) are highly needed in order to extend the range of applications of this class of polymers. Herein, a robust UCST-type copolymer of acrylamide (AAm) and acrylonitrile (AN) (poly(AAm-co-AN)) was prepared by reversible addition fragmentation chain transfer (RAFT) polymerization and its thermo-induced aggregation behavior in aqueous media was studied. At temperature below the UCST, the copolymer chains were aggregated together. The aggregate size was found to be larger with increasing AN contents and became smaller upon dilution of the copolymer solutions. While above the UCST, the copolymer chains were expanded and weekly associated in solution. The association between the copolymer chains formed smaller aggregates with increasing the AN contents or the dilution of the solutions. A model is proposed to explain such aggregation-association behavior of the Fig. 1. Figure 1. Schematic illustration of the proposed thermos-induced aggregation behavior of the poly(AAm-co-AN) in aqueous solution. T2 - World Congress on Living Polymerizations and Polymers 2016 CY - Budapest, Hungry DA - 29.05.2016 - 03.06.2016 KW - Polymer KW - UCST PY - 2016 AN - OPUS4-36491 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hollamby, M. J. A1 - Aratsu, K. A1 - Pauw, Brian Richard A1 - Rogers, S. E. A1 - Smith, A. J. A1 - Yamauchi, M. A1 - Lin, X. A1 - Yagai, S. T1 - Simultaneous SAXS and SANS Analysis for the Detection of Toroidal Supramolecular Polymers Composed of Noncovalent Supermacrocycles in Solution N2 - Molecular self-assembly primarily occurs in solution. To better understand this process, techniques capable of probing the solvated state are consequently required. Smallangle scattering (SAS) has a proven ability to detect and characterize solutions, but it is rarely applied to more complex assembly shapes. Here, small-angle X-ray and neutron scattering are applied to observe toroidal assemblies in solution. Combined analysis confirms that the toroids have a core–shell structure, with a p-conjugated core and an alkyl shell into which solvent penetrates. The dimensions determined by SAS agree well with those obtained by (dried-state) atomic force microscopy. Increasing the number of naphthalene units in the molecular building block yields greater rigidity, as evidenced by a larger toroid and a reduction in solvent penetration into the shell. The detailed structural analysis demonstrates the applicability of SAS to monitor complex solution-based selfassembly. KW - Nanorings KW - Self-assembly KW - Small-angle scattering KW - Supramolecular chemistry KW - Toroids PY - 2016 DO - https://doi.org/10.1002/anie.201603370 SN - 1433-7851 SN - 1521-3773 IS - 128 SP - 10044 EP - 10047 PB - Wiley-VCH Verlag GmbH CY - Weinheim AN - OPUS4-37144 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jakubowski, Norbert T1 - ICP-MS with Sector Field Devices N2 - This lecture is an introduction to ICP-MS with a double focusing magnetic sector mass analyzer. It offers fundamental background, a thorough discussion of analytical features, and state of the art information on applications. Different types of double focusing instruments also are considered. Specific topics include fundamental aspects of ICP-MS (physical properties of a double focusing instrument, operational characteristics in comparison with quadrupole instruments); analytical characteristics (spectral and non-spectral interferences, figures of merit in low and high resolution modes, blanks and memory effects, HPLC and GC interfaces), and applications (industrial including ultra-pure reagents and alloys, environmental, geological, and biomedical materials). T2 - Winter Conference on Plasma Spectrochemistry CY - Tucson, Arizona, USA DA - 10.01.2016 KW - High-resolution ICP-MS KW - Figures of merit KW - Interfaces KW - Applications KW - Ultra-trace analysis PY - 2016 AN - OPUS4-37148 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grauel, Bettina T1 - Nd-sensitized tri-doped UCNP systems N2 - This presentation gives a short overview of the PhD student's research topics and interests, within the scope of the 2016 UPCON Spring School. T2 - UPCON 2016 Spring School CY - Breslau, Poland DA - 25.05.2016 KW - UCNP KW - Nd-sensitizer PY - 2016 AN - OPUS4-37223 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grauel, Bettina A1 - Würth, Christian A1 - Wiesholler, L. M. A1 - Hirsch, T. A1 - Resch-Genger, Ute T1 - Nd as sensitizer in NaYF4:Yb,Er,Nd tri-doped upconversion nanocrystals N2 - In recent years, upconversion nanocrystals (UCNC) have shown great promise for biological and medical applications, mainly because of their excitation in the NIR region, which provides minimum fluorescence background and a rather deep penetration into biological samples, as opposed to excitation in the visible or UV region. Moreover, they show a multitude of characteristic narrow emission bands as basis for ratiometric measurements. Commonly, Yb is the sensitizer of choice, because of a comparatively high absorption cross section, simple energy scheme, and rather efficient energy transfer to the activator, mostly Er, Tm or Ho. A main disadvantage of the use of Yb as sensitizer for biological and medical applications is its absorption band at 976 nm and hence the use of an excitation wavelength at which water has a non-negligible absorption. This can lead to significant sample heating, especially at long illumination times or high excitation power densities, and thus, tissue damage or even cell death. A possible solution is the tri-doping of UCNC with Nd as sensitizer, which can be excited efficiently at around 800 nm, where water absorption is at minimum. The use of Nd as a sensitizer and Yb as a bridge between Nd and the activator Er in NaYF₄ nanocrystals is a relatively new way to overcome the problems of heating of samples in an aqueous environment. Disadvantages can arise from the tri-doping, which can favor non-radiative relaxation due to the more complicated excitation process compared to e.g., simple Yb,Er-doped UCNC, which might lower the upconversion quantum yields in these tri-doped systems. In order to quantify clear advantages, NaYF₄:Yb,Er,Nd nanoparticles were synthesized and spectroscopically studied using an 8 W 804 nm laser diode and a custom-designed Edinburgh instruments FSP980 spectrometer. Wavelength-dependent studies of the emission intensities and the decay kinetics of these tri-doped UCNC at different excitation power densities and excitation pulse widths revealed the clear advantages of preventing water absorption on measurable luminescence signals. We were able to show the influence of pulse width and excitation power density on the luminescence intensities and decay kinetics lifetimes at different emission wavelengths. Additionally, we can clearly discern power density-dependent and independent peaks in the emission spectra. In summary, we demonstrate that the tri-doping of NaYF₄:Yb,Er,Nd nanoparticles is a very promising approach to render UCNC more efficient and to make them better suitable for biological and medical applications requiring measurements in aqueous environment. T2 - UPCON 2016 Conference CY - Breslau, Poland DA - 23.05.2016 KW - UCNP KW - Nd-sensitizer KW - excitation power density PY - 2016 AN - OPUS4-37224 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Frenzel, Florian T1 - Spectroscopic study of plasmon enhanced upconversion nanoparticles N2 - The presentation gave an overview of the topic, the aims and the task allocation of the M-ERA.NET founded project named “Nanohype”. In this project four research teams working hand in hand on computational modeling, synthesis and experimental validation to design novel metal-shelled Upconversion-NP combining plasmonic interactions. As Ph.D. student at the BAM I am responsible for the optical characterization (measurements of lifetimes, Quantum Yields and PL emissions ) of these promising novel systems. T2 - SpringSchool, UpCon2016 CY - Wrocław (Breslau), Polen DA - 25.05.2016 KW - Field Enhancement KW - Upconversion KW - Core-Shell KW - FRET KW - Plasmonic PY - 2016 AN - OPUS4-37225 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Büchner, T. A1 - Drescher, D. A1 - Merk, V. A1 - Traub, Heike A1 - Guttmann, P. A1 - Werner, St. A1 - Jakubowski, Norbert A1 - Schneider, G. A1 - Kneipp, J. T1 - Biomolecular environment, quantification, and intracellular interaction of multifunctional magnetic SERS nanoprobes N2 - Multifunctional composite nanoprobes consisting of iron oxide nanoparticles linked to silver and gold nanoparticles, Ag–Magnetite and Au–Magnetite, respectively, were introduced by endocytic uptake into cultured fibroblast cells. The cells containing the non-toxic nanoprobes were shown to be displaceable in an external magnetic field and can be manipulated in microfluidic channels. The distribution of the composite nanostructures that are contained in the endosomal system is discussed on the basis of surfaceenhanced Raman scattering (SERS) mapping, quantitative laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) micromapping, and cryo soft X-ray tomography (cryo soft-XRT). Cryo soft-XRT of intact, vitrified cells reveals that the composite nanoprobes form intra-endosomal aggregates. The nanoprobes provide SERS signals from the biomolecular composition of their surface in the endosomal environment. The SERS data indicate the high stability of the nanoprobes and of their plasmonic properties in the harsh environment of endosomes and lysosomes. The spectra point at the molecular composition at the surface of the Ag–Magnetite and Au–Magnetite nanostructures that is very similar to that of other Composite structures, but different from the composition of pure silver and gold SERS nanoprobes used for intracellular investigations. As shown by the LA-ICP-MS data, the uptake efficiency of the magnetite composites is approximately two to three times higher than that of the pure gold and silver nanoparticles. KW - Nanoparticles KW - SERS KW - Cell KW - LA-ICP-MS KW - X-ray tomography PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-371811 DO - https://doi.org/10.1039/c6an00890a SN - 0003-2654 VL - 141 IS - 17 SP - 5096 EP - 5106 PB - Royal Society of Chemistry CY - Cambridge, UK AN - OPUS4-37181 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kage, Daniel A1 - Hoffmann, Katrin A1 - Göhde, W. A1 - Thiele, T. A1 - Schedler, U. A1 - Resch-Genger, Ute T1 - Lifetime-encoded microparticles - application to flow cytometry N2 - Analytical methods require efficient and versatile strategies to measure an increasing number of analytes that can be used in conjunction with established platforms like flow cytometry. Spectral multiplexing suffers from problems such as spectral crosstalk and often requires different excitation light sources increasing instrumentation costs. Thus, the number of distinguishable reporters with intensity-based barcodes is limited. An alternative can be lifetime encoding for discrimination of fluorophores based on their fluorescence decay kinetics. We report on the suitability of µm-sized polymer particles stained with organic dyes for lifetime encoding. These dyes are excitable at a standard laser diode wavelength and detectable within a single spectral window. For lifetime-based discrimination, these dyes display sufficiently different luminescence decay kinetics. We present the spectroscopic properties of these beads and address challenges like the limited number of detectable photons in a flow for the reliable discrimination. These studies are expected to pave the road to new applications of fluorescence lifetime multiplexing for time-domain flow cytometry. T2 - DPG Spring Meeting 2016 CY - Regensburg, Germany DA - 06.03.2016 KW - flow cytometry KW - lifetime encoding KW - life sciences KW - fluorescence KW - polymer particles PY - 2016 AN - OPUS4-37153 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kage, Daniel A1 - Hoffmann, Katrin A1 - Wittkamp, M. A1 - Ameskamp, J. A1 - Göhde, W. A1 - Thiele, T. A1 - Schedler, U. A1 - Resch-Genger, Ute T1 - Lifetime-encoded microparticles for application in flow cytometry N2 - The steadily increasing number of analytes, especially in bioanalytics and environmental contexts, requires the development of efficient and versatile methods for the simultaneous determination of different parameters within a single run. Additionally, these methods should be applicable in conjunction with established platform technologies like flow cytometry. Fluorescence techniques have proven to fulfill these requirements. Commonly performed spectral multiplexing utilizing a color code suffers from several problems, such as the sensitivity of fluorescence intensity measurements to fluctuations in excitation light intensity and dye concentration and hence, photobleaching and spectral crosstalk limiting the achievable number of detection channels. Moreover, it typically requires different costly excitation light sources. T2 - Innovation Forum Senftenberg 2016 CY - Senftenberg, Germany DA - 01.06.2016 KW - flow cytometry KW - lifetime encoding KW - life sciences KW - fluorescence KW - polymer particles PY - 2016 AN - OPUS4-37154 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hsiao, I.-L. A1 - Bierkandt, Frank A1 - Reichardt, Ph. A1 - Luch, A. A1 - Huang, Y.-J. A1 - Jakubowski, Norbert A1 - Tentschert, J. A1 - Haase, A. T1 - Quantification and visualization of cellular uptake of TiO2 and Ag nanoparticles: comparison of different ICP-MS techniques N2 - Safety assessment of nanoparticles (NPs) requires techniques that are suitable to quantify tissue and cellular uptake of NPs. The most commonly applied techniques for this purpose are based on inductively coupled plasma mass spectrometry (ICP-MS). Here we apply and compare three different ICP-MS methods to investigate the cellular uptake of TiO2 (diameter 7 or 20 nm, respectively) and Ag (diameter 50 or 75 nm, respectively) NPs into differentiated mouse neuroblastoma cells (Neuro-2a cells). Cells were incubated with different amounts of the NPs. Thereafter they were either directly analyzed by laser ablation ICP-MS (LA-ICP-MS) or were lysed and lysates were analyzed by ICP-MS and by single particle ICP-MS (SP-ICP-MS). KW - Nanoparticles KW - Single particle ICP-MS KW - Laser ablation ICP-MS KW - Cellular internalization KW - Neurons PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-371620 DO - https://doi.org/10.1186/s12951-016-0203-z SN - 1477-3155 VL - 14 SP - Article 50 AN - OPUS4-37162 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mielke, Johannes A1 - Martınez-Blanco, J. A1 - Peters, M. V. A1 - Hecht, S. A1 - Grill, L. T1 - Observing single-atom diffusion at a molecule-metal interface N2 - The dynamics at the interface between a close-packed porphyrin monolayer and Au(111) is investigated by time-dependent scanning tunneling microscopy, detecting the motion of single-interface adatoms in real space. Imaging sequences reveal predominant switching of the molecular appearance in adjacent molecules, pointing to a spatial correlation that is consistent with adatom diffusion from one molecule to the next. In some cases, the number of switching molecules is drastically increased, indicating collective switching events. In addition to the thermally induced motion of adatoms at the interface, also voltage pulses from the microscope tip can induce the process—revealing different yields in agreement with the model of adatom hopping. KW - STM KW - molecular switch KW - single molecule KW - switching dynamics KW - porphyrin KW - Au(111) PY - 2016 UR - http://journals.aps.org/prb/abstract/10.1103/PhysRevB.94.035416 DO - https://doi.org/10.1103/PhysRevB.94.035416 VL - 94 IS - 3 SP - 035416-1 EP - 035416-7 PB - American Physical Society AN - OPUS4-37177 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Johann, Sergej A1 - Kammermeier, Michael A1 - Müller, Maximilian A1 - Strangfeld, Christoph T1 - RFID sensor systems embedded in concrete – systematical investigation of the transmission characteristics N2 - Long-term completely embedded sensor systems offer innovative possibilities for structural health monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external reader device. To evaluate characteristics and conditions of this concept, a systematical investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper. T2 - 8th European Workshop On Structural Health Monitoring CY - Bilbao, Spain DA - 05.07.2016 KW - Structural health monitoring KW - Embedded sensor KW - Energy harvesting KW - Wireless sensors KW - RFID sensors KW - Transmission characteristics PY - 2016 SP - 1 EP - 5 AN - OPUS4-37129 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Strangfeld, Christoph A1 - Johann, Sergej A1 - Kammermeier, Michael A1 - Müller, Maximilian T1 - RFID sensor systems embedded in concrete – systematical investigation of the transmission characteristics N2 - Long-term completely embedded sensor systems offer innovative possibilities for structural health Monitoring of concrete structures. Measuring of relevant parameters, e.g., temperature, humidity, or indication of corrosion can be performed with low energy sensors. This allows to implement passive RFID sensor systems without cable connection and battery, which are power supplied exclusively by the electromagnetic field from the external Reader device. To evaluate characteristics and conditions of this concept, a systematical Investigation of the transmission characteristics with variation of relevant parameters, as communication frequency, installation depth, type of concrete, moisture content, etc. is currently carried out in an interdisciplinary research project at BAM. First results are presented in this paper. T2 - 8th European Workshop On Structural Health Monitoring CY - Bilbao, Spain DA - 05.07.2016 KW - Embedded sensor KW - Energy harvesting KW - Wireless sensors KW - RFID sensors KW - Transmission characteristics KW - Structural health monitoring PY - 2016 AN - OPUS4-37130 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Daum, Werner A1 - Gong, Xing A1 - Hofmann, Detlef A1 - Basedau, Frank A1 - Schukar, Vivien A1 - Westphal, Anja A1 - Sahre, Mario A1 - Beck, Uwe T1 - New self - diagnostic fiber optical sensor technique for structural health monitoring N2 - Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined. T2 - 32nd DANUBIA ADRIA SYMPOSIUM on Advances in Experimental Mechanics CY - Starý Smokovec, Slovakia DA - 22.09.2015 KW - Self-diagnostic fiber optical sensor KW - Magnetostrictive metal coating KW - Magnetic field KW - Fiber bragg grating PY - 2016 DO - https://doi.org/10.1016/j.matpr.2016.03.038 SN - 2214-7853 VL - 3 IS - 4 SP - 1009 EP - 1013 AN - OPUS4-37131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kotschate, Daniel A1 - Gohlke, Dirk A1 - Eisentraut, M. T1 - Reference block design for high resolution ultrasound immersion tank N2 - In respect of modern approaches in material sciences and highly increased requirements on materials on safety relevant components, quality management and non-destructive testing reclaims a steadily increased meaning. The destructive meaning of measuring the degree of purity is defined in DIN EN 10247 through metallurgical investigations, especially microsections. For and comparable, but non-destructive testing due ultrasonic testing, the material the SEP 1927 is a well-defined industry standard. A novel and alternative way of reference block construction was focused by this work. The proposed amendments, regarding the manufactoring and machining, are less time and cost consuming. Verified by measurements the presented reference block fits the same acoustical characteristics and the requirements of the guideline. T2 - World Conference on Non-Destructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Immersion tank testing KW - SEP 1927 KW - Degree of purity KW - High resolution ultrasonic testing PY - 2016 AN - OPUS4-36850 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kotschate, Daniel A1 - Gohlke, Dirk A1 - Eisentraut, Mark T1 - Reference block design for high resolution ultrasound immersion tank N2 - In respect of modern approaches in material sciences and highly increased requirements on materials on safety relevant components, quality management and non-destructive testing reclaims a steadily increased meaning. The destructive meaning of measuring the degree of purity is defined in DIN EN 10247 through metallurgical investigations, especially microsections. For and comparable, but non-destructive testing due ultrasonic testing, the material the SEP 1927 is a well-defined industry standard. A novel and alternative way of reference block construction was focused by this work. The proposed amendments, regarding the manufacturing and machining, are less time and cost consuming. Verified by measurements the presented reference block fits the same acoustical characteristics and the requirements of the guideline. T2 - 19th World Conference on Non-Destructive Testing CY - Munich, Germany DA - 13.06.2016 KW - SEP 1927 KW - Degree of purity KW - High resolution ultrasonic testing KW - Immersion tank testing PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-368512 VL - 2016 SP - Paper X15, 1 EP - 4 AN - OPUS4-36851 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stockmann, Jörg M. A1 - Hertwig, Andreas A1 - Beck, Uwe T1 - Visualization of low-contrast surface modifications: thin films, printed pattern, laser-induced changes, imperfections, impurities, and degradation N2 - Industrial quality control (QC) nowadays requires the visualization of surface modifications from the macro-scopic to the microscopic or even nanoscopic scale. This is a prerequisite to the evaluation of functionality and reliability, the detection of defects and their separation of artefacts. The diversity of applications ranges from low-E glazings and solar panels, micro- and optoelectronics, micro- and smart devices to sensor-on-chip and lab-on-chip systems [1]. Optical microcopy (light, confocal laser scanning, white light interference) as established QC-tool is operated at normal incidence, i.e. p- and s-polarization are undistinguishable. Either light-intensity in terms of grey scale and colour or intensity-correlated effects of phase shifts are used. In case of ellipsometry, operated at oblique incidence, p- and s-polarization matter, and amplitude ratios and phase shifts upon reflection are measured. Hence, information content must be much higher. The visualization of surface modifications may be very challenging for coating/substrate systems of either al-most identical optical constants, e.g. transparent films on substrates of the same material, or minor film thick-ness, substance quantity and affected area, e.g. ultra-thin or island films. Ellipsometry gives access to the con-trast of intensity (I), amplitude ratio (Ψ), and phase shift (Δ) with nanometer-scaled vertical and micrometer-scaled lateral sensitivity, one is able to identify tiny changes within an unmodified surface. As both mapping ellipsometry (ME) and imaging ellipsometry (IE) are operated in the optical far-field, surface inspection is also possible on the macroscopic scale. Near the Brewster-angle of the bare, undamaged, clean, and fresh substrate, the contrast to add-on and sub-off features is superior. Fig. 1 shows three examples of ellipsometric imaging, i.e. a thin SnO:Ni film on SiO2/Si (Fig. 1a), a dried stain of an anti-body solution on cyclo-olefin-polymer (COP) shown in Fig. 1b, and a polyimide film residue on SiO2/Si (Fig. 1c). For all of these examples, ellipsometry provides much better contrast between substrate and surface modification than optical microscopy, sometimes primarily caused by the oblique incidence (Figs. 1a and 1c), in other cases related to the phase sensitivity of ellipsometry (Fig. 1b). Other examples are laser surface modifications and the corrosion of glass. In these cases, optical microscopy and IE yield to similar results, how-ever only ellipsometry gives access to modelling. Further investigated coating/substrate systems are 100Cr6 steel, native oxide on silicon, borosilicate glass, and the polymer polycarbonate with deposited films of graphene and ta-C:H, printed and dried pattern of liquids such as water, cleaning agents, and dissolved silicone. Besides imaging ellipsometry, referenced spectral ellipsometry (RSE) has been applied, combining the advantages of both optical microscopy (fast measurement) and ellipsometry (high sensitivity to tiny modifications). T2 - International Conference on Spectroscopic Ellipsometry (ICSE-7) CY - Berlin, Germany DA - 06.06.2016 KW - Ellipsometry KW - Thin films KW - Impurities KW - Degradation PY - 2016 AN - OPUS4-37068 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Standardization of fluorescence measurements: Design, development, validation, and fabrication of format-adaptable fluorescence standards for intensity, spectral, and temporal quantities N2 - Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging, due to their many advantages like comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Drawbacks are , however, signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are time-dependent due to the aging of instrument components, and difficulties to measure absolute fluorescence intensities. Thus, there is a considerable need for standards for intensity, spectral, and temporal fluorescence quantities to meet the increasing need for instrument performance validation and global trends to harmonize physicochemical measurements. In this respect, instrument calibration strategies together with different types of fluorescence standards are presented as well as design concepts for robust, easy-to-use, and format-adaptable fluorescence standards useable for the determination of different fluorescence parameters and a broad variety of fluorescence techniques. T2 - SALSA-Kolloquien CY - Berlin, Germany DA - 07.06.2016 KW - Fluorescence KW - Standard KW - Quality assurance KW - Spectral correction KW - Quantum yield PY - 2016 AN - OPUS4-37070 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Siegel, G. A1 - Mockenhaupt, F.H.M.E. A1 - Behnke, A.-L. A1 - Ermilov, Eugeny A1 - Winkler, K. A1 - Pries, A.R. A1 - Malmsten, M. A1 - Hetzer, R. A1 - Saunders, R. A1 - Lindman, B. T1 - Lipoprotein binding to anionic biopolyelectrolytes and the effect of glucose on nanoplaque formation in arteriosclerosis and Alzheimer's disease N2 - Arteriosclerosis with its clinical sequelae (cardiac infarction, stroke, peripheral arterial occlusive disease) and vascular/Alzheimer dementia not only result in far more than half of all deaths but also represent dramatic economic problems. The reason is, among others, that diabetes mellitus is an independent risk factor for both disorders, and the number of diabetics strongly increases worldwide. More than one-half of infants in the first 6 months of life have already small collections of macrophages and macrophages filled with lipid droplets in susceptible segments of the coronary arteries. On the other hand, the authors of the Bogalusa Heart Study found a strong increase in the prevalence of obesity in childhood that is paralleled by an increase in blood pressure, blood lipid concentration, and type 2 Diabetes mellitus. Thus, there is a clear linkage between arteriosclerosis/Alzheimer's disease on the one hand and diabetes mellitus on the other hand. Furthermore, it has been demonstrated that distinct apoE isoforms on the blood lipids further both arteriosclerotic and Alzheimer nanoplaque formation and therefore impair flow-mediated vascular reactivity as well. Nanoplaque build-up seems to be the starting point for arteriosclerosis and Alzheimer's disease in their later full clinical manifestation. In earlier work, we could portray the anionic biopolyelectrolytes syndecan/perlecan as blood flow sensors and lipoprotein receptors in cell membrane and vascular matrix. We described extensively molecular composition, conformation, form and function of the macromolecule heparan sulfate proteoglycan (HS-PG). In two supplementary experimental settings (ellipsometry, myography),we utilized isolated HS-PG for in vitro nanoplaque investigations and isolated human coronary artery segments for in vivo tension measurements. With the ellipsometry-based approach, we were successful in establishing a direct connection on a molecular level between diabetes mellitus on the one side and arteriosclerosis/Alzheimer's disease on the other side. Application of glucose at a concentration representative for diabetics and leading to glycation of proteins and lipids, entailed a significant increase in arteriosclerotic and Alzheimer nanoplaque formation. IDLapoE4/E4 was by far superior to IDLapoE3/E3 in Plaque build-up, both in diabetic and non-diabetic patients. Recording vascular tension of flow-dependent reactivity in blood substitute solution and under application of different IDLapoE isoforms showed an impaired vasorelaxation for pooled IDL and IDLapoE4/E4, thus confirming the ellipsometric investigations. Incubation in IDLapoE0/E0 (apoE “knockout man”), however, resulted in a massive flowmediated contraction, also complemented by strongly aggregated nanoplaques. In contrast, HDL was shown to present a powerful protection against nanoplaque formation on principle, both in the in vitro model and the in vivo scenario on the endothelial cell membrane. The competitive interplay with LDL is highlighted through the flow experiment, where flow-mediated, HDL-induced vasodilatation remains untouched by additional incubation with LDL. This is due to the four times higher affinity for the proteoglycan receptor of HDL as compared to LDL. Taken together, the studies demonstrate that while simplistic, the ellipsometry approach and the endothelialmimicking proteoglycan-modified surfaces provide information on the initial steps of lipoprotein-related Plaque formation, which correlates with findings on endothelial cells and blood vessels, and afford insight into the role of lipoprotein deposition and Exchange phenomena at the onset of these pathophysiologies. KW - Diabetes mellitus and Alzheimer's disease KW - HS-PG flow sensor and lipoprotein receptor KW - Glucose and nanoplaque formation KW - IDLapoE3/E3 and IDLapoE4/E4 isoforms KW - HDL protection KW - β-amyloid (1–42) PY - 2016 DO - https://doi.org/10.1016/j.cis.2016.02.001 SN - 0001-8686 VL - 232 SP - 25 EP - 35 AN - OPUS4-37078 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Liu, J.-Y. A1 - Hou, X.-N. A1 - Tian, Y. A1 - Jiang, L. A1 - Deng, S. A1 - Röder, B. A1 - Ermilov, Eugeny T1 - Photoinduced energy and charge transfer in a bis(triphenylamine)-BODIPY-C60 artificial photosynthetic system N2 - Triphenylamines (TPAs), boron dipyrromethenes (BODIPYs) and fullerenes C60 are excellent building blocks for the design of artificial photosynthetic systems. In the present work, we report the synthesis, characterization and detailed photophysical studies of a novel (TPA)2–BODIPY–C60 tetrad in polar and nonpolar solvents. The absorption spectrum of this compound covered virtually the entire visible Region (350–700 nm) and could be interpreted as a superposition of the spectra of individual components. Upon TPA-part excitation, a fast and very efficient excitation energy transfer (EET) delivers the excitation to the BODIPY moiety resulting in complete quenching of the TPA first excited singlet state as well as the appearance of the BODIPY fluorescence. The efficiency of EET process was estimated to be 1. Direct or indirect (via EET) excitation of the BODIPY-part of the tetrad is followed by photoinduced charge transfer to the charge-separated state BODIPY+–C60- irrespective of the solvent used. In polar N,N-dimethylformamide (DMF)charge recombination occurs directly to the ground state with the Charge recombination rate, kCR, slower than 108 s-1, whereas in nonpolar toluene (TOL) a small energy gap between the charge-separated state and first excited singlet state of the BODIPY moiety facilitates the back charge transfer process. The latter results in the appearance of thermally activated delayed fluorescence. The rate of charge separation was found to be ca. 2 times faster in TOL than in DMF. KW - Charge transfer KW - Energy transfer KW - Artificial photosynthesis KW - BODIPY KW - TPA KW - Fullerene C60 PY - 2016 DO - https://doi.org/10.1039/c6ra06841c SN - 2046-2069 VL - 6 IS - 62 SP - 57293 EP - 57305 AN - OPUS4-37080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fischer, Daniel A1 - Hertwig, Andreas A1 - Beck, Uwe A1 - Kormunda, M. A1 - Esser, N. T1 - Ellipsometric characterization of metal doped SnOx thin films for SPREE-based gas sensors N2 - Gas sensors are an important tool in various areas for example in industrial process control as well as Gas sensors are an important tool in various areas for example in industrial process control as well as safety applications or in research. A useful gas detector should be selective, precise, stable and cost-effective. In the present research a surface based gas detection technique is investigated using the SPR effect with ellipsometric readout. This technique is called surface plasmon resonance enhanced ellipsometry (SPREE). The sensor consists of a gold layer (40 nm) top-coated with a doped metal-oxide (M:SnOₓ, 5 nm). The coating is added by magnetron sputtering with doped targets with different doping concentrations. It could be shown that, without the top-coating, these type of sensors can detect various gases, e.g. CO, H2, O2, O3, He, N2, with sensitivities down to the ppm range (in air). The goal of the present study is to characterize the additional coating materials in dependence of the coating conditions. With the help of the doped-metal oxide, the sensitivity increases dramatically by a factor of 100. Additionally, a selectivity for specific gases is observed which depends on the doping conditions of the coating. Changing the properties of the plasma coating process and the doping metal gives access to a variety of different layers and enables us to find the best conditions. T2 - Leibniz Institut für Analytische Wissenschaften ISAS e.V. - Kolloqium CY - Berlin, Germany DA - 05.05.2016 KW - Ellipsometry KW - SPR effect KW - SnOx KW - Gas sensors PY - 2016 AN - OPUS4-37034 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech, Anja A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 SP - Paper 889, 1 EP - 2 AN - OPUS4-37035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Deiting, D. A1 - Börno, Fabian A1 - Hanning, S. A1 - Kreyenschmidt, M. A1 - Seidl, T. A1 - Otto, M. T1 - Investigation on the suitability of ablated carbon as an internal standard in laser ablation ICP-MS of polymers N2 - The conventional quantitative method for the analysis of inorganic elements in polymer matrices is a complex and time consuming process that presents a significant risk for error. Typically, polymers are digested in a microwave oven or other devices under high temperature and pressure for several hours while employing different mixtures of high purity acids. In many cases, particularly when high concentrations of doped elements are present, the digestion is often incomplete and therefore the reproducibility depends strongly on the type of polymer and additives used. A promising alternative technology that allows for the direct analysis of these polymers without digestion is laser ablation ICP-MS. Due to a lack of available reference materials and the presence of matrix dependent effects, a precise calibration cannot be obtained. In order to compensate for the matrix dependent effects the use of internal standardization is necessary. In this study the correlation between the carbon released during the ablation process and the 13C signal detected by ICP-MS and its use as an internal standard are investigated. For this purpose, twenty-one virgin polymer materials are ablated; the released carbon is determined and correlated with the corresponding integrated 13C signal. The correlation resulted in a direct relationship between the ablated carbon and 13C signal demonstrating the potential ability to neglect at least some of the matrix dependent and transport effects which occur during the laser ablation of virgin polymers. KW - Laser ablation KW - ICP-MS KW - Polymer PY - 2016 DO - https://doi.org/10.1039/C6JA00020G SN - 0267-9477 VL - 31 IS - 8 SP - 1605 EP - 1611 PB - Royal Society of Chemistry CY - Cambridge, UK AN - OPUS4-37092 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Andreas A1 - Zhang, Zeyu A1 - Slater, L. A1 - Kruschwitz, Sabine A1 - Halisch, M. T1 - Induced polarization and pore radius - a discussion N2 - Permeability estimation from spectral induced polarization (SIP) measurements is based on a fundamental premise that the characteristic relaxation time (t) is related to the effective hydraulic radius (reff) controlling fluid flow. The approach requires a reliable estimate of the diffusion coefficient of the ions in the electrical double layer. Others have assumed a value for the diffusion coefficient, or postulated different values for clay versus clay-free rocks. We examine the link between t and reff for an extensive database of sandstone sampleswhere mercury porosimetry data confirm that reff is reliably determined from a modification of the Hagen-Poiseuille equation assuming that the electrical tortuosity is equal to the hydraulic tortuosity. Our database does not support the existence of 1 or 2 distinct representative diffusion coefficients but instead demonstrates strong evidence for 6 orders of magnitude of variation in an apparent diffusion coefficient that is well correlated with both reff and the specific surface area per unit pore volume (Spor). Two scenarios can explain our findings: (1) the length-scale defined by t is not equal to reff and is likely much longer due to the control of pore surface roughness; (2) the range of diffusion coefficients is large and likely determined by the relative proportions of the different minerals (e.g. silica, clays) making up the rock. In either case, the estimation of reff (and hence permeability) is inherently uncertain from SIP relaxation time. T2 - IP Workshop 2016 CY - Aarhus, Denmark DA - 06.06.2016 KW - pore radius KW - mercury intrusion capillary pressure KW - spectral induced polarization KW - relaxation time PY - 2016 AN - OPUS4-37116 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kruschwitz, Sabine T1 - Measuring moisture in building material - an overview N2 - In Germany there is an existing built infrastructure worth about 50 trillion Euros. The expected lifetimes of individual structures are up to 100 years. Considerable costs (annually about 35 billion Euros, the trend continues upwards) are involved in order to maintain and rehabilitate both residential as well as transportation infrastructure buildings. Most damages we observe on our built infrastructure are moisture-induced processes. Consequently reliable moisture measurement tools a highly needed for meaningful building diagnosis investigations. The optimal moisture measuring technique would be non-destructive, fast, repeatable, reliable, independent of steel in the vicinity, the surface condition or possible salt loads of the material under test. Since this is unfortunately not the case for any non-destructive method, it is often very difficult to decide for users which method to use for the particular testing problem. The only standardized methods in Germany are the “direct” and destructive Darr- and the CM tests. Although they can be highly accurate (when handled with care during the sampling), they deliver only punctual information and cannot be used for monitoring. The other, non-destructive methods are based on the change in humidity-dependent physical material properties. The underlying physics, their particular advantages and disadvantages are discussed in this paper. T2 - Building Safety Symposium CY - Hong Kong, China DA - 22.04.2016 KW - Non-destructive methods KW - Moisture measuring KW - Electrical methods KW - Microwave PY - 2016 AN - OPUS4-37118 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Weidner, Steffen T1 - Dispersities of Polyesters of Various Diphenols Prepared by Irreversible Polycondensations N2 - Polyesters of bisphenol-A, bisphenol-P, catechol, and sebacic acid are prepared and different synthetic methods are compared. The diphenols are condensed with sebacoyl chloride either in dichloromethane/pyridine or in refl uxing chlorobenzene without HCl-acceptor. Further- more, bisphenol-A acetate is polycondensed with sebacic acid in bulk. All experiments are worked up so that fractionation is avoided. The extent of cyclization is estimated by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) and the molar mass distribution by size exclusion chromatography (SEC). Polycondensations in solution yield larger fractions of cyclics and higher dispersities (up to 11). Polycondensations in bulk give lower fractions of cycles and dispersities from 4.6 to 6.3 for high molar mass polyesters or 2.8 to 3.5 for low molar mass products. Characteristic curves describing the dependence of the dispersity on the initial monomer concentration are elaborated. KW - cyclization KW - dispersity KW - mass spectra KW - polycondensation KW - polyesters PY - 2016 DO - https://doi.org/10.1002/macp.201600004 IS - 217 SP - 1361 EP - 1369 PB - Wiley-VCH Verlag CY - Weinheim AN - OPUS4-37120 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schneider, Ralf A1 - Weigert, Florian A1 - Lesnyak, V. A1 - Leubner, S. A1 - Lorenz, T. A1 - Behnke, Thomas A1 - Dubavik, A. A1 - Joswig, J.-O. A1 - Resch-Genger, Ute A1 - Gaponik, N. A1 - Eychmüller, A. ED - Resch-Genger, Ute ED - Schneider, Ralf T1 - pH and concentration dependence of the optical properties of thiol-capped CdTe nanocrystals in water and D2O N2 - The optical properties of semiconductor nanocrystals (SC NCs) are largely controlled by their size and surface chemistry, i.e., the chemical composition and thickness of inorganic passivation shells and the chemical nature and number of surface ligands as well as the strength of their bonds to surface atoms. The latter is particularly important for CdTe NCs, which – together with alloyed CdₓHg₁₋ₓTe – are the only SC NCs that can be prepared in water in high quality without the need for an additional inorganic passivation shell. Aiming at a better understanding of the role of stabilizing ligands for the control of the application-relevant fluorescence features of SC NCs, we assessed the influence of two of the most commonly used monodentate thiol ligands, thioglycolic acid (TGA) and mercaptopropionic acid (MPA), on the colloidal stability, photoluminescence (PL) quantum yield (QY), and PL decay behavior of a set of CdTe NC colloids. As an indirect measure for the strength of the coordinative bond of the ligands to SC NC surface atoms, the influence of the pH (pD) and the concentration on the PL properties of these colloids was examined in water and D₂O and compared to the results from previous dilution studies with a set of thiol-capped Cd₁₋ₓHgₓTe SC NCs in D₂O. As a prerequisite for these studies, the number of surface ligands was determined photometrically at different steps of purification after SC NC synthesis with Ellman’s test. Our results demonstrate ligand control of the pH-dependent PL of these SC NCs, with MPA-stabilized CdTe NCs being less prone to luminescence quenching than TGA-capped ones. For both types of CdTe colloids, ligand desorption is more pronounced in H₂O compared to D₂O, underlining also the role of hydrogen bonding and solvent molecules. KW - Quantum dots KW - Fluorescence KW - Ligand analysis KW - Nano particles PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-371253 DO - https://doi.org/10.1039/c6cp03123d VL - 18 IS - 28 SP - 19083 EP - 19092 PB - RSC CY - Cambridge AN - OPUS4-37125 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maul, R. A1 - Schloß, Svenja A1 - Herz, C. A1 - Lamy, E. A1 - Koch, Matthias A1 - Rohn, S. T1 - Phomopsins in legumes - a multidimensional approach N2 - Fungal secondary metabolites such as phomopsin A (PHO-A) produced by the fungus Diaporthe toxica are referred to as “emerging” mycotoxins. Recently, we developed a biosynthetic approach to gain access to 15N-isotopically labelled PHO-A as internal standard (IS) for PHO-A matrix independent quantification of PHO-A in various commodities. Aim of the present work was to elucidate the applicability of the new IS for accurate quantification and to investigate the phomopsin formation on various legume seeds as well as plant material. In summary, the applicability of the SIDA-HPLC-MS/MS method could be proven and the potential of D. toxica to produce high amounts of phomopsins under unfavorable conditions on lupins and other legume seeds could be shown. Moreover, a novel toxic methylated PHO-A derivative was unveiled in natural samples infested with D. toxica. T2 - 38. Mycotoxin-Workshop CY - Berlin, Germany DA - 02.05.2016 KW - Phomopsin-Derivate KW - Leguminosen KW - Stabilisotopenverdünnungsanalyse KW - HPLC-MS/MS KW - HRMS-Identifizierung KW - Toxizität PY - 2016 AN - OPUS4-37056 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Biyikal, Mustafa A1 - Gawlitza, Kornelia A1 - Dropa, T. A1 - Urban, M. A1 - Costero, A. M. A1 - Martínez-Mánez, Ramon A1 - Rurack, Knut T1 - A rapid and sensitive strip-based quick test for nerve agents Tabun, Sarin, and Soman using BODIPY-modified silica materials N2 - Test strips that in combination with a portable fluorescence reader or digital camera can rapidly and selectively detect chemical warfare agents (CWAs) such as Tabun (GA), Sarin (GB), and Soman (GD) and their simulants in the gas phase have been developed. The strips contain spots of a hybrid indicator material consisting of a fluorescent BODIPY indicator covalently anchored into the channels of mesoporous SBA silica microparticles. The fluorescence quenching response allows the sensitive detection of CWAs in the μg m−3 range in a few seconds. KW - Chemical warfare agents KW - Fluorescence KW - Hybrid sensor materials KW - Nerve gases KW - Test strip analysis PY - 2016 DO - https://doi.org/10.1002/chem.201601269 SN - 0947-6539 SN - 1521-3765 VL - 22 IS - 32 SP - 11138 EP - 11142 PB - Wiley CY - Online Library AN - OPUS4-37063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Behnke, Thomas A1 - Moser, Marko A1 - Quevedo, Pablo A1 - Nirmalananthan-Budau, Nithiya A1 - Weigert, Florian A1 - Würth, Christian A1 - Hoffmann, Katrin A1 - Ermilov, Eugeny A1 - Pauli, Jutta T1 - Simple methods, validation concepts, and reference materials for the characterization of functional nanomaterials and microparticles N2 - The surface chemistry / functionalization of nanomaterials and microparticles largely controls the stability of these materials as well as their solubility and subsequent biofunctionalization and their interactions with biological systems. Moreover, in the case of some nanomaterials like semiconductor quantum dots or lanthanide-based upconversion nanocrystals, the ligand shell strongly affects their optical properties, e.g., via passivation of surface states and traps that favor luminescence quenching or the protection of surface atoms from quenching water molecules. This renders analytical methods for the quantification of surface groups like functionalities very important. Targets of broad interest are here amino, carboxyl, alkine and maleimide groups used for common bioconjugation reactions and typical ligands like thiols and polyethylene glycol (PEG) molecules of varying length, used for the tuning of material hydrophilicity and biocompatibility, minimization of unspecific interactions, prevention of biofouling, and enhancement of blood circulation times as well as surface-bound biomolecules like streptavidin or other biomolecules relevant e.g., for diagnostic assays. Here, we focus on simple optical methods relying on standard laboratory instrumentation, validated by method comparison and/or mass balances and present examples for their use for the characterization of different types of nanomaterials and microparticles. T2 - Innovationsforum Senftenberg CY - Senftenberg, Germany DA - 01.06.2016 KW - Surface chemistry KW - Functional group analysis KW - Thiol assay KW - Fluorescence KW - Nanomaterial KW - Nanoparticle KW - PEG KW - Ligand KW - Semiconductor quantum dot KW - Quantum yield KW - Quantification KW - Method validation KW - Integrating sphere spectroscopy KW - Fluorescence standard PY - 2016 N1 - Geburtsname von Nirmalananthan-Budau, Nithiya: Nirmalananthan, N. - Birth name of Nirmalananthan-Budau, Nithiya: Nirmalananthan, N. AN - OPUS4-37111 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Applications and challenges of luminescence-based detection methods in the life and material sciences N2 - Luminescence-based detection methods, ranging from fluorescence spectroscopy for photophysical and mechanistic studies over sensing applications, chromatographic separation techniques and the microarray technology with fluorescence detection to fluorescence microscopy, flow cytometry, single molecule spectroscopy, and molecular imaging to integrating sphere spectroscopy, are among the most widely used methods in the life and material sciences. This is due to e.g., their unique sensitivity enabling the detection of single molecules, potential for multiplexing, ease of combination with spatial resolution, and suitability for remote sensing. Many of these advantages are closely linked to the choice of suitable molecular and nanoscale fluorescent reporters, typically required for signal generation. This includes organic dyes without and with sensor function, fluorophore-encoded polymeric and silica nanoparticles as well as nanocrystalline systems like semiconductor quantum dots and upconversion phosphors, emitting in the visible (vis), near-infrared (NIR), and IR (infrared). Current challenges present the environment sensitivity of most fluorophores, rendering fluorescence spectra, measured intensities/fluorescence quantum yields, and fluorescence decay kinetics matrix-dependent, and instrument-specific distortions of measured fluorescence signals that need to be considered for quantification and comparability of data, particularly fluorescence spectra. Here, current applications of luminescence-based methods and different types of reporters will be presented. In this context, suitable spectroscopic tools for the characteri-zation of the optical properties of fluorescent reporters and fluorophore-encoded microparticles, analytical tools for the determination of the surface chemistry of different types of particles, and different multiplexing strategies will be discussed. T2 - 9th Meeting of Engineering of Functional Interfaces CY - Wildau,Germany DA - 03.07.2016 KW - Fluorescence KW - Multiplexing KW - Lifetime KW - Nanomaterial KW - Nanoparticle KW - PEG KW - Ligand KW - Semiconductor quantum dot KW - Quantum yield KW - Quantification KW - Upconversion nanoparticle KW - Integrating sphere spectroscopy KW - NIR KW - IR KW - Fluorescence standard KW - Calibration PY - 2016 AN - OPUS4-37112 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Müller, Christina A1 - Pavlovich, Mato A1 - Bartsch, Ludwig A1 - Rosenthal, Martina A1 - Holstein, R. T1 - Simulation and experimental results of manual UT-testing of hollow wheel set axles during the education of operators N2 - The reliability of wheel set axle testing is of high importance because small discontinuities caused during manufacturing or rock fall impacts during operation might cause growing cracks during the operation load cycles. While most of the axles are tested by automated UT-systems today, the basic education of railway NDT operators is still manual testing providing the basic understanding and skills for the operators. In Germany it is a common rule that NDT operators in the railway branch need to refresh their knowledge and skills every five years including a refresh examination. The testing results from these exercises and from a parallel round robin test have been sampled at the DGZfP Railway Education Centre in Wittenberge for a period of about 5 years. The results of the operators written in test record sheets were compared with the “true” test crack or notch position in the axles used for examination. In this way the testing results could be categorized into “hits” and “misses” and the “hits” were further evaluated due to correct position and adequate amplitude height. Considering some thousand indications documented by the operators during the refresh examination and comparing transition bow, shaft and seat it was a highlight to see that the operators reach their best detection rate in the transition bow of the wheel axle set while this is often the most difficult part concerning the UT-echoes. Fortunately this is due to their raised awareness in the transition bow region because this is the most dangerous region with respect to fracture mechanics. For two selected axles the experimental set up of 45° and 70° inward and outward UT-testing were also simulated showing clearly the difficulties of the UT-echoes detection of some specific test defects. T2 - XXII Saint-Petersburg Conference on Ultrasonic Testing of Metals and Advanced Materials (UTM 2016) CY - St. Petersburg, Russia DA - 24.05.2016 KW - Ultrasound KW - Manual testing KW - NDT reliability KW - Fault tree analysis KW - Education of NDT personnel PY - 2016 AN - OPUS4-37013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF ED - Halisch, M. ED - Kruschwitz, Sabine ED - Schmitt, M. ED - Weller, Andreas T1 - Quantification of rock structures with high resolution X-ray μ-CT for laboratory SIP measurements N2 - Spectral Induced Polarization (SIP) measurements are used in many different ways to characterize natural rocks and soils. Main foci of interest are the enhanced characterization of the causes of IP-effects in clastic rocks (especially sandstones), the interactions between the matrix-fluid-system and within the electrical double layers as well as the correlation with “classical” petrophysical parameters, such as specific surface area, permeability, mercury intrusion capillary pressure (MICP) and others. Nevertheless, for all of these investigations, knowledge of the inner structure of the sample material is essential in order to create reliable and validated models as well as to interpret and to assess the data most completely. Unfortunately, many of the methods used, to get access to the inner structure of rocks are destructive (e.g. MICP, thin sectioning, etc.) and the valuable sample is lost. In addition, data is either of volume integrated nature or only available for the 2D case and the usage of sister cores does not necessarily lead to reliable results. In this paper, the authors showcase the possibilities of non-destructive and three dimensional X-ray computed tomography and of enhanced image analysis capabilities for the quantification of rock structures at the pore scale. T2 - IP Workshop 2016 CY - Aarhus, Denmark DA - 06.06.2016 KW - μ-CT imaging, KW - Rock structure KW - Digital image analysis KW - Pore geometry KW - Grain geometry KW - SIP PY - 2016 SP - 1 EP - 4 CY - Aarhus, Denmark AN - OPUS4-37024 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Götschel, S. A1 - Höhne, Christian A1 - Kolkoori, Sanjeevareddy A1 - Mitzscherling, Steffen A1 - Prager, Jens A1 - Weiser, M. T1 - Ray tracing boundary value problems: simulation and SAFT reconstruction for ultrasonic testing N2 - The application of advanced imaging techniques for the ultrasonic inspection of inhomogeneous anisotropic materials like austenitic and dissimilar welds requires information about acoustic wave Propagation through the material, in particular travel times between two Points in the material. Forward ray tracing is a popular approach to determine traveling paths and arrival times but is ill suited for inverse problems since a large number of rays have to be computed in order to arrive at prescribed end points. In this contribution we discuss boundary value problems for acoustic rays, where the ray path between two given points is determined by solving the Eikonal equation. The implementation of such a two Point boundary value ray tracer for sound field simulations through an austenitic weld is described and its efficiency as well as the obtained results are compared to those of a forward ray tracer. The results are validated by comparison with experimental results and commercially available UT simulation tools. As an application, we discuss an implementation of the method for SAFT (Synthetic Aperture Focusing Technique) reconstruction. The ray tracer calculates the required travel time through the anisotropic columnar grain structure of the austenitic weld. There, the formulation of ray tracing as a boundary value Problem allows a straightforward derivation of the ray path from a given transducer Position to any pixel in the reconstruction area and reduces the computational cost considerably. T2 - 19th World Conference on Non-Destructive Testing 2016 CY - München, Germany DA - 13.06.2016 KW - Ultrasonic testing KW - SAFT KW - Ray tracing KW - Simulation PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-370494 UR - www.ndt.net/?id=19437 SP - ID 19437, 1 EP - 8 AN - OPUS4-37049 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Boehm, Rainer A1 - Brackrock, Daniel A1 - Montag, Hans-Joachim A1 - Heckel, Thomas T1 - What is the benefit of the total focussing method and full matrix capture for ultrasonic imaging using the phased array technique N2 - In the last two decades automated ultrasonic inspection devices took over a lot of applications that prior have been carried out using manual inspection with the evaluation of A-scans only. In parallel phased array systems have been developed and brought to the market which offer detailed and fast control over the sound field. When applying automated inspection phased array systems for UT measurements imaging of the recorded data in combination with the probe positioning data is used for the evaluation of inspections. B-Scan, C-Scan and S-Scan images are typically used with this setup. For more sophisticated applications with linear arrays echo tomography and syntethic aperture focusing technique (SAFT) are well known methods and often applied for high resolution image reconstruction. Since channel count of phased array systems is constantly rising, matrix arrays with up to 256 elements entered the market. Signal processing in the matrix domain became 3D. Since some years the Total Focusing Method (TFM) is an additional imaging tool for these type of application. It is based on the Full Matrix Capture (FMC) using the elements of phased array probes as separate transmitters and receivers. In this contribution we discuss the common ground of SAFT and TFM as well as the differences between these imaging tools. The combined use of automated inspection, matrix arrays and signal processing for high resolution measurements is a challenging task where a very long parameter list has to be taken into account. Under which conditions which elements of the full matrix should be taken for the reconstruction for best results? Based on examples taken from measured and simulated echo signals it will be shown how image resolution can be optimized in dependence of different parameters like the distance between transmitters and receivers and their directivity patterns, the depth of echo source and the specimen geometry. T2 - 19th World Conference on Non-Destructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Ultrasonic testing KW - Ultrasonic imaging KW - Phased array KW - Total focussing method KW - Full matrix capture PY - 2016 UR - https://www.wcndt2016.com/programme AN - OPUS4-37051 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Götschel, S. A1 - Weiser, M. A1 - Höhne, Christian A1 - Kolkoori, Sanjeevareddy A1 - Mitzscherling, Steffen A1 - Prager, Jens T1 - Ray tracing boudary value problems: simulation and SAFT reconstruction for ultrasonic testing N2 - The application of advanced imaging techniques for the ultrasonic inspection of inhomogeneous anisotropic materials like austenitic and dissimilar welds requires information about acoustic wave propagation through the material, in particular travel times between two points in the material. Forward ray tracing is a popular approach to determine traveling paths and arrival times but is ill suited for inverse problems since a large number of rays have to be computed in order to arrive at prescribed end points. In this contribution we discuss boundary value problems for acoustic rays, where the ray path between two given points is determined by solving the eikonal equation. The implementation of such a two point boundary value ray tracer for sound field simulations through an austenitic weld is described and its efficiency as well as the obtained results are compared to those of a forward ray tracer. The results are validated by comparison with experimental results and commercially available UT simulation tools. As an application, we discuss an implementation of the method for SAFT (Synthetic Aperture Focusing Technique) reconstruction. The ray tracer calculates the required travel time through the anisotropic columnar grain structure of the austenitic weld. There, the formulation of ray tracing as a boundary value problem allows a straightforward derivation of the ray path from a given transducer position to any pixel in the reconstruction area and reduces the computational cost considerably. T2 - 19th World Conference on Non-Destructive Testing 2016 CY - Munich, Germany DA - 13.06.2016 KW - Ultrasonic testing KW - SAFT KW - Ray tracing KW - Simulation PY - 2016 UR - www.ndt.net/?id=19437 UR - https://www.wcndt2016.com/portals/wcndt/bb/Fr1H4.pdf AN - OPUS4-37052 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Habel, Wolfgang R. A1 - Krebber, Katerina A1 - Daum, Werner T1 - Results in standardization of FOS to support the use of SHM systems N2 - Measurement and data recording systems are important parts of a holistic Structural Health Monitoring (SHM) system. New sensor technologies such as fiber-optic sensors are often used; however, standards (or at least guidelines) are not yet available or internationally approved. This lack in standardization makes the acceptance of FOS technologies in complex SHM systems substantially difficult. A standard family for different FOS technologies is therefore being developed that should help to design SHM systems in an optimal way. International standardization activities take place in several standardization bodies such as IEC and ASTM, and within SHM societies such as ISHMII. The paper reports on activities in standardization of fiber-optic sensors, on results already achieved, and on newly started projects. Combined activities of fiber sensor experts and SHM experts from Civil Engineering are presented. These contributions should help owners of structures as well as developers of sensors and monitoring systems to select effective and validated sensing technologies. Using these standards, both parties find recommendations how to proceed in development of SHM systems to evaluate the structural behavior based on e.g. standardized fiber optic sensors, and to derive necessary measures, e.g. the optimal maintenance strategy. T2 - Sixth European Workshop on Optical Fibre Sensors CY - Limerick, Ireland DA - 30.05.2016 KW - Fiber-optic sensor KW - Standard KW - Temperature KW - Strain KW - Monitoring KW - Structural health KW - Application PY - 2016 DO - https://doi.org/10.1117/12.2236863 SN - 0277-786X VL - 9916 SP - 991625-1 EP - 991625-4 AN - OPUS4-37053 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hutchinson, R. A1 - Jakubowski, Norbert A1 - Traub, Heike A1 - Esteban-Fernandez, Diego A1 - Wilkins, J. A1 - Summerfield, L. A1 - O´Connor, C. A1 - McLachlin, K. T1 - The NWRiMAGE - an elemental microscope N2 - The NWRiMAGE provides unique technologies for high-speed imaging with genuine sub-micron ablation. In March 2015 ESI installed the first NWR iMAGE at the Bundesanstalt für Materialforschung und –prüfung (BAM) in Berlin, and since then it has undergone extensive use in bio-imaging. The Dual Concentric Injector (DCI), a new interface between laser and plasma, has been integrated into ESI´s TwoVol2 ablation cell. This technology was developed in collaboration with the University of Loughborough, and provides single shot transition at the ICP-MS of < 20 ms with high sample transport efficiency, giving superior signals above background and improve spatial resolution capability. Here we describe some data showing ultra-fast transitions of single shot ablation, sub-micron ablation experiments and rapid acquired imaging. T2 - 13th European Workshop on Laser Ablation CY - Ljubljana, Slovenia DA - 12.07.2016 KW - Laser ablation KW - Trace element KW - Imaging PY - 2016 AN - OPUS4-36999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Halisch, M. A1 - Kruschwitz, Sabine A1 - Schmitt, M. A1 - Weller, Andreas T1 - Quantification of rock structures with high resolution X-Ray μ-CT for laboratory SIP measurements N2 - Spectral Induced Polarization (SIP) measurements are used in many different ways to characterize natural rocks and soils. Main foci of interest are the enhanced characterization of the causes of IP-effects in clastic rocks (especially sandstones), the interactions between the matrix-fluid-system and within the electrical double layers as well as the correlation with “classical” petrophysical parameters, such as specific surface area, permeability, mercury intrusion capillary pressure (MICP) and others. Nevertheless, for all of these investigations, knowledge of the inner structure of the sample material is essential in order to create reliable and validated models as well as to interpret and to assess the data most completely. Unfortunately, many of the methods used, to get access to the inner structure of rocks are destructive (e.g. MICP, thin sectioning, etc.) and the valuable sample is lost. In addition, data is either of volume integrated nature or only available for the 2D case and the usage of sister cores does not necessarily lead to reliable results. In this paper, the authors showcase the possibilities of non-destructive and three dimensional X-ray computed tomography and of enhanced image analysis capabilities for the quantification of rock structures at the pore scale. T2 - IP Workshop 2016 CY - Aarhus, Denmark DA - 06.06.2016 KW - SIP KW - μ-CT imaging KW - Rock structure KW - Digital image analysis KW - Pore geometry KW - Grain geometry PY - 2016 AN - OPUS4-37000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Andreas A1 - Zhang, Zeyu A1 - Slater, L. A1 - Kruschwitz, Sabine A1 - Halisch, M. T1 - Induced polarization and pore radius – a discussion N2 - Permeability estimation from spectral induced polarization (SIP) measurements is based on a fundamental premise that the characteristic relaxation time (t) is related to the effective hydraulic radius (reff) controlling fluid flow. The approach requires a reliable estimate of the diffusion coefficient of the ions in the electrical double layer. Others have assumed a value for the diffusion coefficient, or postulated different values for clay versus clay-free rocks. We examine the link between t and reff for an extensive database of sandstone samples where mercury porosimetry data confirm that reff is reliably determined from a modification of the Hagen-Poiseuille equation assuming that the electrical tortuosity is equal to the hydraulic tortuosity. Our database does not support the existence of 1 or 2 distinct representative diffusion coefficients but instead demonstrates strong evidence for 6 orders of magnitude of variation in an apparent diffusion coefficient that is well correlated with both reff and the specific surface area per unit pore volume (Spor). Two scenarios can explain our findings: (1) the length-scale defined by t is not equal to reff and is likely much longer due to the control of pore surface roughness; (2) the range of diffusion coefficients is large and likely determined by the relative proportions of the different minerals (e.g. silica, clays) making up the rock. In either case, the estimation of reff (and hence permeability) is inherently uncertain from SIP relaxation time. T2 - IP Workshop 2016 CY - Aarhus, Denmark DA - 06.06.2016 KW - Pore radius KW - Mercury intrusion capillary pressure KW - Spectral induced polarization KW - Relaxation time PY - 2016 AN - OPUS4-37003 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Andreas A1 - Zhang, Zeyu A1 - Slater, L. A1 - Kruschwitz, Sabine A1 - Halisch, M. T1 - Induced polarization and pore radius - a discussion N2 - Permeability estimation from spectral induced polarization (SIP) measurements is based on a fundamental premise that the characteristic relaxation time (t) is related to the effective hydraulic radius (reff) controlling fluid flow. The approach requires a reliable estimate of the diffusion coefficient of the ions in the electrical double layer. Others have assumed a value for the diffusion coefficient, or postulated different values for clay versus clay-free rocks. We examine the link between t and reff for an extensive database of sandstone samples where mercury porosimetry data confirm that reff is reliably determined from a modification of the Hagen- Poiseuille equation assuming that the electrical tortuosity is equal to the hydraulic tortuosity. Our database does not support the existence of 1 or 2 distinct representative diffusion coefficients but instead demonstrates strong evidence for 6 orders of magnitude of variation in an apparent diffusion coefficient that is well correlated with both reff and the specific surface area per unit pore volume (Spor). Two scenarios can explain our findings: (1) the length-scale defined by t is not equal to reff and is likely much longer due to the control of pore surface roughness; (2) the range of diffusion coefficients is large and likely determined by the relative proportions of the different minerals (e.g. silica, clays) making up the rock. In either case, the estimation of reff (and hence permeability) is inherently uncertain from SIP relaxation time. T2 - IP Workshop 2016 CY - Aarhus, Denmark DA - 06.06.2016 KW - Pore radius KW - Mercury intrusion capillary pressure KW - Spectral induced polarization KW - Relaxation time PY - 2016 SP - 1 EP - 4 AN - OPUS4-37004 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kruschwitz, Sabine T1 - Moisture measurement methods N2 - Moisture can cause imperfect sealings, faulty roof constructions, cracks and other kind of damages. For measuring the moisture in construction materials like concrete and screed, there are destructive(direct) and non-destructive(indirect) methods, that can be used. This presentation gives an overview and a comparison of these methods. T2 - Nondestructive Testing and Evaluation in Civil Engineering and Surveying - Advanced Training 2016 CY - Berlin, Germany DA - 14.07.2016 KW - Moisture KW - Non-destructive testing PY - 2016 AN - OPUS4-37005 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heckel, Thomas A1 - Boehm, Rainer A1 - Spruch, W. A1 - Jacob, S. T1 - Increasing the sensitivity of ultrasonic phased array wheel set axle inspection by using signal processing N2 - Der einwandfreie Zustand der Radsätze von Schienenfahrzeugen ist von größter Bedeutung für den sicheren Betrieb. Die Radsatzwellen werden durch eine große Zahl von Lastwechseln individuell unterschiedlich beansprucht. Dabei spielen viele Einflüsse wie äußere statische und dynamische Lasten, innere Lasten aufgrund von Unwuchten und inneren Spannungen und Umweltbedingungen entscheidende Rollen. Eine regelmäßige Prüfung ist daher obligatorisch. BTD entwickelt im Rahmen eines MNPQ-Projektes in Kooperation mit der BAM eine Phased Array Technik zur automatisierten Prüfung von Radsatzwellen im eingebauten Zustand. Die schwierigen Ankoppelbedingungen aufgrund der begrenzten Zugänglichkeit, der komplexen Geometrie sowie Farbschichten und Schmutz auf der Radsatzwelle stellen hierbei große Herausforderungen dar. Zu deren Bewältigung werden neben optimierten Prüfköpfen, einer in die Wasservorlaufstrecke integrierten akustischen Linse und einer speziellen Ankoppeltechnik auch Signalverarbeitungsalgorithmen eingesetzt. Die Darstellung der Signalverarbeitung ist der Schwerpunkt dieses Beitrages. Mit Hilfe von Messdatensätzen präparierter Testwellen werden verschiedene Algorithmen erprobt und hinsichtlich der Stabilität, dem Verhalten bezüglich der Ankoppelschwankungen und veränderter Wellengeometrien und der Fähigkeit zur automatischen Unterscheidung von Fehler- und Formanzeigen bewertet. Letztlich wird die beste Lösung im entwickelten Prüfsystem eingesetzt. T2 - 19th WCNDT - World Conference on Non Destructive Testing CY - München, Germany DA - 13.06.2016 KW - Ultrasound KW - Phased array KW - Wheelset KW - Railway KW - Signal processing PY - 2016 AN - OPUS4-37008 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kruschwitz, Sabine A1 - Strangfeld, Christoph A1 - Wöstmann, Jens T1 - Measuring screed moisture with EM methods – a comparison of capacitive handheld and microwave resonator probes N2 - We have compared the performance of the typical Darr and CM moisture testing techniques, which are destructive with several non-destructive testing techniques on two types of floor screeds. In case of cement based screeds these destructive tests failed to deliver reliable results. Moreover, our measurements indicate significantly different drying and moisture transport behavior for the investigated cement based and calcium-sulphate based screeds. Whereas we have strong with depth decreasing moisture gradients in the CT material, we observe in the penetrated volumes of our ndt methods basically no clear moisture gradient in the CA samples. The findings with ndt methods could be supported by moisture gradient studies with nuclear magnetic resonance measurements. T2 - 11th Int. Conference on electromagnetic wave interaction with water and moist substances CY - Florenz, Italy DA - 23.5.2016 KW - Moisture KW - Screed KW - Microwave KW - Nuclear magnetic resonance PY - 2016 SP - 77 EP - 84 AN - OPUS4-36674 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Carvalho, Margarida A1 - Schneider, Rudolf A1 - Madder, A. T1 - Addressable Immunoarrays: Protein-Nucleic Acid Conjugate Production N2 - Immunoassays are analytical methods used to track both clinical and environmental parameters. Antibodies or other proteins with similar recognizing activity, are employed, often immobilized onto a modified surface. Addressable microarrays are based on single-stranded DNA oligonucleotides which are normally used to detect aptamers or relevant gene sequences. The use of antibody-oligonucleotide conjugates allows non-directed antibody immobilization from an immunoassay to be converted into DNA hybridization events on the array. Consequently, the diagnostics platform is multiplexed and addressable. Figure 1 is a model representation of the whole biosensor construct. In brief, a surface is coated with streptavidin, and decorated with biotin-modified oligonucleotides of a controlled size and known sequence. These oligonucleotides on the surface also contain a furan motif, which upon irradiation and in the presence of a photosensitizer, is oxidized via single oxygen to a reactive intermediate which crosslinks the immediate opposing base when hybridized with its complementary strand [1]. Antibody-oligonucleotides conjugates still display several concerns due to their heterogeneicity, difficulty of characterization and high price [2]. The being the case, we aim at developing stable, robust, reproducible and well characterized quimeras for the application on te above described immunoarray. Mild chemical conditions are crucial for the antibody stability, therefore bivalent crosslinkers have been employed [2]. Even though the use of these bilinkers is standard for other substrate conjugation (i.e., enzymes, drug payloads, etc.), there is no literature available on the conjugation of small oligonucleotides (< 30 mer) to antibodies using this method. Several protein-nucleic acid conjugates have been therefore developed, and successfully characterized using MALDI-ToF and gel electrophoresis techniques. T2 - SO2S - The singlet Oxygen Strategy - Final Network Meeting CY - Gent, Belgium DA - 14.06.2016 KW - Antibodies KW - Immunoarrays KW - Nucleic acids PY - 2016 AN - OPUS4-36680 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -