TY - CONF A1 - Niederleithinger, Ernst T1 - Progress in non-destructive testing and monitoring of concrete N2 - The presentation will give an overview on non-destructive testing techniques being developed at the Federal Institute for Materials Research and Testing, Germany (BAM). This includes ultrasonic methods, ground penetration radar, Laser-Induced Breakdown Spectroscopy (LIBS), infrared thermography, pile testing, sensor technology and building scanner. A focus of the talk will be ultrasonic methods, which are well established in various aspects of concrete testing. They are used for imaging the interior geometry of constructions, estimation of concrete strength or monitoring lab investigations. However, so far the detection of distributed damages, especially in an early stage, has been almost impossible. The arrival of new technologies as embedded transducers and sensitive data processing techniques adopted from seismology has opened new field of work. Recent research has been focused to detect changes in concrete elements induced by stress, temperature, moisture or chemical attacks by permanent monitoring. Techniques as Coda Wave Interferometry can resolve changes in ultrasonic velocity in the order of 1*10-5. In addition, many researchers believe that the investigation of nonlinear effects can be used to characterize damages. The presentation will give a wrap up of ultrasonic techniques currently used in practice. This will include echo based methods as multi-channel/multi-offset imaging of structural elements using commercial and prototype devices. Imaging methods as SAFT and RTM will be shortly discussed. The focus will be on the emerging techniques used for monitoring. New types of sensors will be presented as well as the devices used in laboratory and field applications. Insight will be given on the various influence factors on ultrasonic signals and various ways of feature extraction and data processing. The results of lab experiments will be shown to demonstrate the detection of various kind of damages from mechanical load, ASR, corrosion to fatigue. The experiences with our first installations in real constructions (bridges, tunnel) will also be presented. T2 - CIE Research Seminar, University of Western Sydney, New South Wales CY - Sydney, Australia DA - 15.12.2016 KW - Ultrasound KW - Concrete KW - Monitoring KW - Imaging PY - 2016 AN - OPUS4-38732 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Plasma fundamentals and diagnostics N2 - Short 4-hour course on plasma physics and plasma diagnostics T2 - January 8-13, Winter Plasma Conference CY - Tucson, USA DA - 08.01.2016 KW - PLasma physics KW - Plasma diagnostics PY - 2016 AN - OPUS4-38772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Modeling chemical reactions in laser induced plasmas N2 - Under the assumption of local thermal equilibrium, a numerical algorithm is proposed to find the equation of state for laser-induced plasmas (LIPs) in which chemical reactions are permitted in addition to ionization processes. The Coulomb interaction in plasma is accounted for by the Debye–Hückel method. The algorithm is used to calculate the equation of state for LIPs containing carbon, silicon, calcium, chlorine, nitrogen, and argon. The equilibrium reaction constants are calculated using the latest experimental and ab initio data of spectroscopic constants for the molecules N2, C2, Si2, CN, Cl2, SiN, SiC, CaCl, CaCl2 and their positive and (if existed) negative ions. The algorithm is incorporated into a fluid dynamic numerical model based on the Navier–Stokes equations describing an expansion of LIP plumes into an ambient gas. The dynamics of LIP plumes obtained by the ablation of SiC, CaCl2, solid silicon, or solid carbon in an ambient gas containing N2 and Ar is simulated to study formation of molecules and molecular ions. A particular attention is paid to formation of anions Cl−, Cl2−, Si2−, C2−, CN−, and SiN− in LIPs. T2 - Winter Plasma Conference, January 8-13 2016 CY - Tucson, USA DA - 08.01.2016 KW - Plasma KW - Plasma modeling PY - 2016 AN - OPUS4-38774 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nöller, Renate T1 - Mit Zinnoberrot markiert-Pigmentanalyse zur Zuordnung von Manuskripten der Seidenstraße N2 - Zinnober (HgS) ist neben Eisenoxiden (Fe2O3 oder FeOOH) das am häufigsten verwendete mineralische Rotpigment. Die relativ seltenen Vorkommen in der Natur wurden schon in der Vorgeschichte abgebaut und in Gräbern und auf Felsmalerei als rote Farbe verwendet. In Asien spielt Zinnoberrot als Schreibtusche eine wichtige Rolle. Besonders zur Zeit des Buddhismus findet sich das Rot verstärkt auch auf Wandmalerei und Statuen. Schon früh beherrschte man die synthetische Herstellung und Optimierung des Pigments mit Zusatzstoffen, so dass von einer regional unterschiedlichen Verarbeitung auszugehen ist. Auf Grund seiner physikalisch-chemischen Eigenschaften (gute Eindringtiefe, konservierende Wirkung) wurde das leuchtend rote Farbpigment auch als Handelsware genutzt. Die Pigmentanalyse gibt Auskunft über - kulturelle Vorkommen, die Nutzung von Zinnober als Rotpigment in einem bestimmten Kontext. - natürliche Vorkommen, die Herkunft des Minerals entsprechend der regionalen Bildungsbedingungen. - Werkstätten, die Herstellung als Farbpigment mit unterschiedlichen Techniken. Vorgestellt werden rote Tinten und Tuschen auf Schriftstücken der Seidenstraßenkulturen mit Zinnober als charakteristisch für eine bestimmte Tradition in der Verwendung und möglicher Indikator für kulturellen Austausch. Die in unterschiedlichen Schriften und Sprachen erhaltenen Manuskriptfragmente gelangten Anfang des letzten Jahrhunderts von der Oasenstadt Turfan nach Berlin, wo sie entziffert und kulturhistorisch erforscht werden. Die chemische Zusammensetzung ihrer Rottöne wird differenziert und in Rückkopplung mit der historischen Klassifikation der untersuchten Objekte verglichen. Eine solche Identifizierung von Farbtypen kann zur Einordnung von Kulturobjekten fragwürdiger Herkunft herangezogen werden. T2 - Konservierungswissenschaft im Dialog 2016, Öffentliche Vortragsreihe des Rathgen-Forschungslabors CY - Staatliche Museen zu Berlin, Germany DA - 2016 KW - Zinnoberrot KW - Pigmentanalyse KW - Manuskripte KW - Seidenstraßenkultur PY - 2016 AN - OPUS4-44796 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lehmann, Jens T1 - Potentialfeldmessung - Korrosionsprüfung von Stahlbetonbauwerken N2 - Durch das alkalische Porenwassermilieu ist Stahl im Beton vor Korrosion geschützt. Unter un-günstigen Umgebungsbedingungen (Karbonatisierung, Chlorideintrag) kann die passive Deck-schicht auf der Stahloberfläche zerstört werden. Im weiteren Verlauf können sich korrosionsbe-dingte Folgeschäden, wie Risse und Abplatzungen am Bauwerk ergeben. Um notwendige Sanie-rungsmaßnahmen sind frühzeitige und weitgehend zerstörungsfrei ermittelte Informationen über das aktuelle Korrosionsverhalten der Stahlbewehrung von großer Bedeutung. Die Potentialfeld-messung ist ein etabliertes und weit verbreitetes Verfahren zur Beurteilung des Korrosionszu-standes der Bewehrung in Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche aktiv korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. T2 - Fachtagung Prüfen von Beton CY - Berlin, Germany DA - 06.10.2016 KW - Stahlbeton KW - Spannbeton KW - Korrosion KW - Zertörungsfreie Prüfung PY - 2016 AN - OPUS4-37711 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Studying cellular uptake and processing of nanoparticles by LA-ICP-MS N2 - In recent years, elemental imaging of biological samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining in importance. Latest improvements regarding spatial resolution (down to 1 µm) and washout time make LA-ICP-MS particularly interesting for single cell analysis. Many current nanomaterials can serve as contrast agents in cellular or tissue imaging, drug delivery vehicles or therapeutics, whereas others can cause toxic effects. In order to evaluate nano-bio interactions, the number of nanoparticles (NPs) inside cells as well as their localisation within cellular substructures is of particular interest. LA-ICP-MS was used to study the NP pathway from uptake, via intracellular processing up to cell division. Fibroblast cells were incubated with different metallic NPs under varying experimental conditions. For LA analysis the cells were fixed with formaldehyde and dried. Our results show that LA-ICP-MS is able to localise NP aggregates within cellular substructures. The NPs accumulate in the perinuclear region in the course of intracellular processing, e.g. multivesicular fusion and endosomal maturation, but do not enter the nucleus [1, 2]. A strong dependence of NP uptake on concentration and incubation time was found. Additionally, the number of NPs internalized by individual cells was determined and variations within the cell population became visible. A new laser ablation system providing a short washout time (50 ms) together with small spot sizes (< 4 µm) and high repetition rates allows high spatial resolution applications. First results of cell imaging will be shown. The findings demonstrate the potential of LA-ICP-MS enabling insight into NP uptake and intracellular distribution dependent on experimental parameters. T2 - 8th Nordic Conference on Plasma Spectrochemistry CY - Loen, Norway DA - 05.06.2016 KW - Imaging KW - LA-ICP-MS KW - Cell KW - Nanoparticles PY - 2016 AN - OPUS4-36500 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - van de Kreeke, Johannes T1 - EPTIS presentation for CNAS and RMPT workshop, Beijing 2016 N2 - Introduction to EPTIS for Chinese and regional audience T2 - RMPT workshop 2016 CY - Beijing, China DA - 20.09.2016 KW - EPTIS KW - Ringversuche KW - Proficiency testing KW - PT KW - ILC PY - 2016 AN - OPUS4-39004 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - IDMS Training N2 - Based on its proven records especially in reference material certification, isotope dilution mass spectrometry (IDMS) is considered as one of the most powerful and most accurate methods for determining amounts of substance. Contrary to other calibration approaches, IDMS does not directly suffer from long-time changes or drifts in instrument sensitivity. Moreover, provided isotopic exchange between the sample and spike is ensured, losses of analyte do not affect the analytical result. Both advantages are based on the fact that IDMS only requires isotope ratio measurements and isotope ratios are largely unaffected by instrumental drift, setup or by matrix, unless an isobaric interference is present. The Consultative Committee for Amount of Substance (CCQM), the world's highest institution for metrology in chemistry, considers IDMS as the most important “Primary Method of Measurement” for amount determination. The total combined uncertainty, according to ISO and EURACHEM guidelines, can easily be calculated via the IDMS equations. Applying it correctly, IDMS has the potential to be a primary method of measurement yielding SI traceable values in the most direct way with combined uncertainties significantly smaller than obtainable by other methods. In general it can be stated that IDMS is the most important reference method for elemental and elemental species analysis, offering highest accuracy and precision or smallest measurement uncertainties, when properly applied. Thus IDMS represents by far the best suited reference method for RM characterisation. Due to its universal applicability IDMS offers sufficient potential to follow future needs in analytical chemistry as well as in the RM sector. This presentation will demonstrate the basic principle of IDMS and will show its Pros and Cons as well as its pitfalls. Possible sources of errors and bias are mentioned and correction models will be discussed. Notice will be given to metrological aspects such as traceability and uncertainty. Differences in the application of thermal ionization mass spectrometry and inductively coupled plasma mass spectrometry are discussed as well as differences between different types of mass spectrometers. This will be illustrated by practical examples from various fields. T2 - Workshop and practical training on isotope dilution mass spectrometry CY - Berlin, Germany DA - 22.02.2016 KW - Isotope dilution mass spectrometry KW - Primary method of measurement KW - Certification PY - 2016 AN - OPUS4-40029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schönhals, Andreas T1 - Behavior of Ultra-Thin POLYMER Films investigated by Nanosized Relaxation Spectroscopy N2 - The glass transition behavior of ultra-thin polymer films is discussed in detail. Further nanosized relxation spectroscopy is introduced in the form of AC chip calorimetry and dielectric spectroscopy employing nanostructured electrodes. These methods arre applied to ultra-thin films. T2 - Soft Matter Seminar Jülich CY - Jülich, Germany DA - 15.12.2016 KW - Ultra-thin polymer films PY - 2016 AN - OPUS4-38714 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krause, Martin T1 - LAUS – Large Aperture Ultraschall N2 - Prinzip und erste Anwendungsbeispiele eines neu entwickelten Ultraschall-Arrays für die bildgebende Echomessung an sehr dicken Betonbauteilen T2 - Fachtagung Bauwerksdiagnose CY - Berlin, Germany DA - 25.02.2016 KW - Ultraschall-Echo KW - Beton KW - Ultraschall-Array KW - Abbildungsverfahren PY - 2016 AN - OPUS4-38855 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Anja T1 - WP3 (A 3.3.5 / 3.3.6) electron spectroscopy of core/shell nanoparticles N2 - The presentation summarizes the progress of activity 3.3.5 and 3.3.6 of the Innanopart project. These activities focus on the investigation of different core@shell nanoparticles using synchrotron-radiation-XPS and AES. T2 - Innanopart 18 Months Meeting (EMPIR) CY - Vienna, Austria DA - 31.10.2016 KW - XPS KW - Synchrotron KW - Depth-Profiling KW - AES KW - Core@Shell Nanoparticles PY - 2016 N1 - Geburtsname von Müller, Anja: Hermanns, A. - Birth name of Müller, Anja: Hermanns, A. AN - OPUS4-38792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane T1 - A round robin test of flash thermography – detectability and quantification of artificial and natural defects in CFRP and metal structures N2 - Within the scope of a DIN INS project, a flash thermography round robin test that evaluates reliability, comparability, and efficiency of different testing situations was organized. The results give information about the detectability of defects, e.g. depending on their size and depth, the evaluation methods and the materials used. Besides, the influences of equipment and parameters used by the participants on the results were analysed. All of the quantitative results as well as the feedback given by the participants will be presented in a DIN committee in order to contribute to a flash thermography standard. T2 - Conference QIRT 2016 CY - Gdansk, Poland DA - 04.07.2016 KW - Active thermography KW - Round robin test KW - CFRP KW - Metal KW - Flash excitation PY - 2016 AN - OPUS4-37511 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schönhals, Andreas T1 - Neutron and dielectric spectroscopy - taking advantage of the strengths of each technique in confinement studies: Vibrational and molecular dynamics of nanoconfined liquid crystals N2 - The effect of a nanometre confinement on the molecular dynamics of liquid crystals was studied by broadband dielectric and neutron spectroscopy. As confining host the molecular sieve Al-MCM-41 (Si/Al=60) with a mean pore diameter of 3 nm was selected. As guest the liquid crystals 8CB and E7 were chosen where the latter does not crystallize but undergoes a glass transition forming a nematic glass. Dielectric spectroscopy shows that for the confined systems one relaxation process is observed. Ist characteristic relaxation time is much lower compared to that of the bulk. No signature of the Phase transition characteristics of the bulk liquid crystal is detected. The temperature dependence of the relaxation time of this relaxation process has to be described by the Vogel-Fulcher-Tammann equation and thus shows similarities to glassy dynamics. The vibrational density of states measured by neutron spectroscopy (IN6, ILL; TOFTOF, MLZ) Shows excess contributions with respect to the Debye density of states (boson peak). For the confined systems the low frequency contributions of the boson peak are suppressed, an effect which is also found for conventional glass forming systems. In addition elastic scans were carried out at the backscattering spectrometer (BS) IN10 at ILL. Such measurements provide an overview about the temperature dependence of the microscopic dynamics. Assuming a Gaussian form for the elastically scattered intensities the effective mean square displacement was calculated. For the nanoconfined samples the mean square displacement is strongly reduced in comparison to the bulk. Also these measurements show the signature of a glass Transition indicated by a change in the temperature dependence of the mean square displacement. For confined E7 the extracted glass transition temperature is shifted by more than 20 K to higher temperatures. Broadband inelastic neutron scattering was carried out by combining time-of-flight (IN6, ILL; TOFTOF, MLZ) and backscattering (IN10, ILL; SPHERES, MLZ) experiments in the time domain. The time dependence of the incoherent intermediate scattering function Sinc(q,t) shows two Relaxation processes which were quantitatively analyzed by fitting the KWW function to the data. The process at shorter times shows a close similarity the methyl group rotation found for polymeric systems. The process at longer times was assigned to glassy dynamics. The obtained data are compared in detail in their temperature dependence to the dielectric results. T2 - Deutsche Neutronenstreutagung 2016 CY - Kiel, Germany DA - 20.09.2016 KW - Neutron scattering KW - Broadband dielectric spectroscopy PY - 2016 AN - OPUS4-37516 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wu, Cheng-Chieh T1 - Ersatzmodell von komplexen geometrischen Strukturen für FEA N2 - Der Grad der Finite-Elemente-Diskretisierung wird vom Verhältnis der Details zur Objektgröße bestimmt. Die Diskretisierung eines großen Objektes mit vielen kleinen Details führt zu einer hohen Anzahl an Elementen bzw. Knotenpunkten. Die Berechnung solcher Körper erfordern nicht nur sehr hohe Rechenzeit, sondern was die Berechnung unmöglich macht, ist der sehr hohe Speicherbedarf. Mit Hilfe eines Ersatzkörpers wird dieses Problem umgangen. T2 - VDI/VDE-GMA Fachausschuss 2.12 "Strukturanalyse und -überwachung in der Bautechnik im Fachbereich Prozessmesstechnik und Strukturanalyse" CY - Darmstadt, Germany DA - 08.09.2016 KW - Ausgleichungsrechnung KW - Inverse Analysis KW - Finite-Elemente-Method PY - 2016 AN - OPUS4-37522 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wu, Cheng-Chieh T1 - Approximate model for geometrical complex structures N2 - Many engineering structures are made of composite materials or metal foam. To simulate the deformational behaviour of these structures often requires a high number of discretisation elements. This in turn yields a very large system of linear equations that are extremely time and memory consuming or practically impossible to solve. It is therefore desirable to find an approach to overcome this obstacle. T2 - 33rd Danubia- Adria Symposium on Advances in Experimental Mechanics CY - Portorož, Slovenia DA - 20.09.2016 KW - Inverse analysis KW - Finite element method KW - Least-squares adjustment PY - 2016 AN - OPUS4-37524 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Helmerich, Rosemarie T1 - Long-Term measurement of vertical displacements at the outer concrete bridges of the Berlin Main Station N2 - The Berlin Main Station was built between 2000 and 2006. At the occasion of the 10th anniversary after the Berlin Main Station was officially opened to train traffic, a view back on eight years of monitoring was given. For the period of the construction with different load cases, the monitoring system was required by the Railway Authorities (Eisenbahnbundesam, EBA) to survey differential vertical displacements between neighbouring supports of the glas roof and the partially prestressed middle bridges. 128 sensors were installed.The data was published in the Internet with access restricted to the BAM scientists and the owner of the station, the German Railways DB AG. T2 - 33rd Danubia- Adria Symposium on Advances in Experimental Mechanics CY - Portorož, Slovenia DA - 20.09.2016 KW - Strain measurements KW - Monitoring KW - Differential displacements KW - Berlin Main Station KW - Hydraulic levelling system KW - Laser-based displacement measuring system PY - 2016 AN - OPUS4-37540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Airborne ultrasonic systems for one-sided inspection using thermoacoustic transmitters N2 - Airborne ultrasonic inspection is performed in through transmission, where the test piece (e.g. adhesive joint or polymer-based composite plate) is placed between the transmitter and the receiver. However, many structures with difficult shapes allow only one-sided inspection. The strong reflection of the signal from the surface overshadows the signals from the inside, so that broadband pulses are required. Thermoacoustic transmission, where the thermal energy of an electrically heated electrode is transformed into the acoustic energy of an ultrasonic wave, opens the possibility to excite broadband pulses and thus to inspect objects with one-sided access. We present various thermoacoustic transducers consisting of an electrically conductive film on a solid substrate. The first type of transducer is a transmitter with an indium-tin-oxide electrode on a glass substrate combined with a laser Doppler vibrometer as a receiver. The second type of transducer combines thermoacoustic transmission and piezoelectric reception, having a titanium electrode as a transmitter deposited onto charged cellular polypropylene serving as a piezoelectric receiver. Using a focusing thermoacoustic transmitter and a separate cellular polypropylene receiver, a through-transmission inspection of a 4 mm thick CFRP test piece with inserts as small as 1 mm was performed. The same emitter and a laser vibrometer as a receiver were used for a one-sided inspection of a Plexiglas block with a cross hole at 15 mm depth. A twin probe consisting of a thermoacoustic transmitter on a cellular polypropylene receiver was applied to a profile measurement on a step wedge with flat bottom holes. The smallest detected diameter of a flat bottom hole was 1 mm. Sound pressure level above 140dB was achieved with each of these transmitters. Thermoacoustic transmitters enable a step towards one-sided air-coupled ultrasonic inspection. T2 - IEEE International Ultrasonics Symposium CY - Tours, France DA - 18.9.2016 KW - Airborne KW - Air-coupled KW - Ferroelectret KW - Thermoacoustic KW - Ultrasonic transducer PY - 2016 AN - OPUS4-37621 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Griepentrog, Michael T1 - Kratzbeständigkeit Prüfmethoden und deren Bewertung N2 - Der Vortrag widmet sich der Kratzbeständigkeit-Prüfmethoden und deren Bewertung und beschreibt Begriffe/Definitionen, Wirtschaftliche Bedeutung der Kratzbeständigkeit, Mess- und Prüfverfahren – allgemein (Anwendbarkeit, Messunsicherheit, Validierung), Mess- und Prüfverfahren – speziell die Erzeugung, Prüfverfahren von Einzel- und Vielfach-Kratzern, die Charakterisierung von Verkratzungen und eine zusammenfassende Bewertung im Einzelnen T2 - SKZ-Seminare für die Kunststoff-Branche: Modifikation der Kratz- und Abriebbeständigkeit CY - Peine, Germany DA - 19.04.2016 KW - Kratzfestigkeit KW - Haftfestigkeit KW - Ritztest KW - Instrumentierte Eindringprüfung KW - Normung PY - 2016 AN - OPUS4-37598 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Westphal, Anja T1 - Altbekannter Watts-Elektrolyt, junge Hightech-Anwendung: Ni- und NiFe-Schichten als magnetostriktive Aktorschicht auf faseroptischen Sensoren N2 - Durch den Einsatz von eingebetteten faseroptischen Sensoren können Bauteile überwacht und frühzeitig Informationen über Materialveränderungen gewonnen werden. Um die Zuverlässigkeit eines solchen Sensors gewährleisten zu können, ist es wichtig, die korrekte Funktion des Sensors im Verbund mit einer Werkstoff-Matrix on-line und in-situ überwachen zu können. Im Rahmen des DFG-Projekts FAMOS² (FAser-basierter Magneto-Optischer SchichtSensor) wurde ein selbstdiagnose-fähiger Schichtsensor entwickelt, welcher mit Hilfe einer magnetostriktiven Aktorschicht validiert werden kann. Durch eine Kombination aus PVD (physical vapour deposition) und ECD (electro-chemical deposition) wird die Aktorschicht auf faseroptischen Sensoren haftfest abgeschieden. Ein äußeres Magnetfeldes dehnt die Aktorschicht und damit auch die Faser reversibel. Diese Dehnung führt zu einer Verschiebung der Bragg-Wellenlänge, welche direkt mit der Stärke des zu messenden Magnetfeldes korreliert. Ein etwa 100 Nanometer dünnes PVD-Schichtsystem aus Chrom und Kupfer dient zunächst als Haftvermittler zwischen Glasfaser und ECD-Schicht. Um eine rotationssymmetrische Schichtabscheidung zu erhalten, erfolgt während der PVD-Beschichtung eine Rotation der Faser. In einem klassischen Watts-Elektrolyten wird dann im zweiten Schritt die eigentliche etwa 30 Mikrometer dicke ECD-Aktorschicht auf die PVD-Schicht abgeschieden. Reine Ni-Schichten werden mit NiFe-Legierungen verglichen. Die Geometrie der Faser stellt für die Herstellung und Charakterisierung der Schichten auf der einen Seite eine besondere Herausforderung dar, bietet aber zugleich auch neue experimentelle Möglichkeiten. So kann ggf. die Entstehung von Spannungen in der Schicht während der ECD-Abscheidung in-situ verfolgt werden, indem die Wellenlängenverschiebung aufgrund der Dehnung des Bragg-Gitters optisch gemessen wird. Die Anpassung der Beschichtungsverfahren an die Fasergeometrie sowie die Charakterisierung und die Eigenschaften der ECD-Schicht werden diskutiert. Insbesondere wird auf den Elastizitätsmodul der Aktorschicht eingegangen, wobei Werte aus der Nanoindentation und dem 2-Punkt-Biegeversuch mit der beschichteten Faser als Biegebalken verglichen werden. T2 - ZVO-Oberflächentage CY - Garmisch-Partenkirchen, Germany DA - 21.09.2016 KW - Selbstdiagnosefähiger FBG-Sensor KW - ECD/PVD-Kombinations-Schichtsystem KW - Magnetostriktive Ni- und NiFe-Schicht KW - Nanoindentation KW - 2-Punkt-Biegeversuch PY - 2016 AN - OPUS4-37505 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grauel, Bettina T1 - Nd-sensitized tri-doped UCNP systems N2 - This presentation gives a short overview of the PhD student's research topics and interests, within the scope of the 2016 UPCON Spring School. T2 - UPCON 2016 Spring School CY - Breslau, Poland DA - 25.05.2016 KW - UCNP KW - Nd-sensitizer PY - 2016 AN - OPUS4-37223 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -