TY - CONF A1 - Klewe, Tim T1 - LIBS ConSort: Development of a sensor-based sorting method for constuction and demolition waste N2 - Closed material cycles and unmixed material fractions are required to achieve high recovery and recycling rates in the building industry. In construction and demolition waste (CDW) recycling, the preference to date has been to apply simple but proven techniques to process large quantities of construction rubble in a short time. This is in contrast to the increasingly complex composite materials and structures in the mineral building materials industry. Manual sorting involves many risks and dangers for the executing staff and is merely based on obvious, visually detectable differences for separation. An automated, sensor-based sorting of these building materials could complement or replace this practice to improve processing speed, recycling rates, sorting quality, and prevailing health conditions. A joint project of partners from industry and research institutions approaches this task by investigating and testing the combination of laser-induced breakdown spectroscopy (LIBS) with near-infrared (NIR) spectroscopy and visual imaging. Joint processing of information (data fusion) is expected to significantly improve the sorting quality of various materials like concrete, main masonry building materials, organic components, etc., and may enable the detection and separation of impurities such as SO3-cotaining building materials (gypsum, aerated concrete, etc.) Focusing on Berlin as an example, the entire value chain will be analyzed to minimize economic / technological barriers and obstacles at the cluster level and to sustainably increase recovery and recycling rates. We present current advances and results about the test stand development combining LIBS with NIR spectroscopy and visual imaging. In the future, this laboratory prototype will serve as a fully automated measurement setup to allow real-time classification of CDW on a conveyor belt. T2 - 21. International Conference on Building Materials (Ibausil) CY - Weimar, Germany DA - 13.09.2023 KW - Material classification KW - Data fusion KW - Circular economy KW - LIBS KW - Recycling PY - 2023 AN - OPUS4-58495 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Völker, Tobias A1 - Gornushkin, Igor B. T1 - Investigation of a method for the correction of self-absorption by Planck function in laser induced breakdown spectroscopy N2 - The electron density and temperature of a laser-induced plasma can be determined from the width and intensity of the spectral lines, provided that the corresponding optical transitions are optically thin. However, the lines in laser induced plasma are often self-absorbed. One of the methods of correction of this effect is based on the use of the Planck function and an iterative numerical calculation of the plasma temperature. In this study, the method is further explored and its inherent errors and limitations are evaluated. For this, synthetic spectra are used that fully correspond to the assumed conditions of a homogeneous isothermal plasma at local thermodynamic equilibrium. Based on the error analysis, the advantages and disadvantages of the method are discussed in comparison with other methods of self-absorption correction. KW - LIBS KW - Self-absorption KW - Planck function PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-572677 DO - https://doi.org/10.1039/D2JA00352J SN - 0267-9477 SP - 1 EP - 6 PB - Royal Society of Chemistry (RSC) AN - OPUS4-57267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Application of LIBS in civil engineering – status, trends and challenges N2 - The main application of LIBS in civil engineering is the detection of harmful ions in concrete, which can penetrate the component through the porous concrete structure. The advantages of LIBS over standard methods are the possibility of multi-element analysis, measurement speed, spatially resolved measurements, and minimal sample preparation. The spatially resolved measurements of LIBS allow the assessment of the heterogeneity of the concrete by measuring separately the chemical composition of the aggregates and the binder matrix. The latter is particularly relevant because the determined elemental distribution can be directly related to the binder matrix. This is not possible with standard methods, since the material is homogenized to powder during sample preparation stage and the determined concentration is thus related to the total mass. In addition to the use of LIBS for the specific analysis of individual harmful ions, LIBS can also be used to estimate the concrete composition and thus determine, for example, the type of cement used. Corresponding information are relevant for the estimation of the remaining service life and for the preparation of a maintenance concept. In recent years, LIBS has been increasingly used in civil engineering. Currently, however, it is primarily used in research institutions and only occasionally in building materials laboratories. Special commercial devices have also been developed, which greatly simplify the application due to the high degree of automation. Mobile LIBS systems allow on-site application. A central point, which limits the use of LIBS in the commercial sector, is the lack of norms and standards. Therefore, within the framework of a project funded by the German government, work has been carried out on the preparation of a leaflet on quantitative chlorine determination in concrete, which will be published this year. In interlaboratory comparisons the robustness and accuracy for the practical application was demonstrated. LIBS also has great potential in the recycling of construction waste in conjunction with hyperspectral sensors. This issue is currently being addressed in a national project. During the presentation, the state of the art of LIBS in civil engineering will be presented, next steps will be discussed, and future challenges will be outlined. T2 - XII international conference on laser induced breakdown spectroscopy (LIBS 2022) CY - Bari, Italy DA - 04.09.2022 KW - LIBS KW - Concrete KW - Chlorine KW - Civil engineering PY - 2022 AN - OPUS4-56535 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Condition assessment of concrete infrastructure with LIBS N2 - Due to the ageing of the infrastructure facilities, a reliable assessment of the condition of concrete structures is of great interest to plan timely and appropriate measures. In concrete structures, pittingcorrosion of the reinforcement is the predominant deterioration mechanism affecting serviceability and eventually structural performance. Determination of quantitative chloride ingress is not only necessary to obtain valuable information on the current condition of a structure, but the data obtained can also be used to predict future developments and the associated risks. An overview of the progress and the possibilities of the application of laser-induced breakdown spectroscopy for concrete analysis in daily civil engineering practice is given. High-resolution 2D measurements of drill cores to determine the penetration of harmful species into concrete is presented. Furthermore, the application of a mobile LIBS system in a parking garage is shown. The system consists of a diode-pumped low-energy laser (3 mJ, 1.5 ns, 100 Hz) and a compact NIR spectrometer. A scanner allows two-dimensional element mapping. Progress towards the establishment of LIBS in a leaflet for the analysis of chlorine ingress into concrete in civil engineering is presented. T2 - Euro-Mediterranean Symposium on Laser-Induced Breakdown Spectroscopy 2021 CY - Gijón, Spain DA - 29.11.2021 KW - LIBS KW - Concrete KW - Chlorine KW - Civil engineering PY - 2021 AN - OPUS4-56536 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Laser Induced Breakdown Spectroscopy – A Tool for the Chemical Investigation of Concrete N2 - LIBS is a complementary method to XRF and can detect all elements without the need for vacuum conditions. Automated systems are already commercially available capable of scanning surfaces with a resolution of up to 0.1 mm within a few minutes. In addition to possible applications in R&D, LIBS is also used for practical applications in building materials laboratories and even on-site. In view of ageing infrastructure facilities, a reliable assessment of the condition of concrete structures is of increasing interest. For concrete structures, the ingress of potential harmful ions is affecting the serviceability and eventually structural performance. Pitting corrosion induced by penetrating chlorides is the dominant deterioration mechanism. Condition assessment based on frequently performed chloride profiling can be useful to identify the extent and evolution of chloride ingress. This could prove to be more economical than extensive repairs, especially for important infrastructure facilities. Currently the most common procedure for determining the chloride content is wet chemical analysis with standard resolution of 10 mm. The heterogeneity is not considered. LIBS is an economical alternative for determining the chloride content at depth intervals of 1 mm or less. It provides 2D distributions of multiple elements and can locate spots with higher concentrations. The results are directly correlated to the mass of binder and can also be performed on-site with a mobile LIBS-System. The application of a LIBS-system is presented. Calibration is required for quantitative analysis. Concrete cores were drilled, sliced and analyzed to determine the 2D-distribution of harmful elements. By comparing the chloride ingress and the carbonation, the interaction of both processes can be visualized in a measurement that takes less than 10 minutes for a 50 mm x 100 mm drill core. A leaflet on the use of LIBS for the chloride ingress assessment has been completed. T2 - NDT-CE 2022 - The International Symposium on Nendestructive Testing in Civil Engineering CY - Zurich, Switzerland DA - 16.08.2022 KW - Chlorides KW - Corrosion KW - Imaging KW - Service life KW - Damage assessment KW - LIBS PY - 2022 AN - OPUS4-56540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Völker, Tobias A1 - Wilsch, Gerd A1 - Gornushkin, Igor B. A1 - Kratochvilo, L. A1 - Pořízka, P. A1 - Kaiser, J. A1 - Millar, S. A1 - et al., T1 - Interlaboratory comparison for quantitative chlorine analysis in cement pastes with laser induced breakdown spectroscopy N2 - Concrete structures experience severe damage during service, for example due to pitting corrosion of rebars caused by the ingress of chlorine (Cl) into the porous concrete structure. The ingress can be monitored using laser-induced breakdown spectroscopy (LIBS), a recently introduced civil engineering technique used to detect Cl in concrete structures in addition to conventional wet chemistry methods. The key advantages of LIBS are high spatial resolution, which is important when analyzing heterogeneous concrete samples, as well as the almost complete absence of sample preparation. To assess LIBS as a reliable analytical method, its accuracy and robustness must be carefully tested. This paper presents the results of an interlaboratory comparison on the analysis of Cl in cement paste samples conducted by 12 laboratories in 10 countries. Two sets of samples were prepared with Cl content ranging from 0.06 to 1.95 wt% in the training set and 0.23–1.51 wt% in the test set, with additional variations in the type of cement and Cl source (salt type). The overall result shows that LIBS is suitable for the quantification of the studied samples: the average relative error was generally below 15%. The results demonstrate the true status quo of the LIBS method for this type of analysis, given that the laboratories were not instructed on how to perform the analysis or how to process the data. KW - LIBS KW - Interlaboratory comparison KW - Round robin test KW - Cement KW - Chlorine PY - 2023 DO - https://doi.org/10.1016/j.sab.2023.106632 SN - 0584-8547 VL - 202 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-57102 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Völker, Tobias A1 - Gottlieb, Cassian A1 - Kapteina, Gesa A1 - Wilsch, Gerd A1 - Millar, Steven A1 - Reichling, Kenji T1 - Neues DGZfP-Merkblatt B14: Quantifizierung von Chlorid in Beton mittels LIBS N2 - Bei der Erhaltung von Stahlbetonbauwerken ist der Chloridgehalt im Beton ein wichtiger Parameter zur Festlegung geeigneter Instandsetzungsmaßnahmen. Die bisher etablierten Verfahren basieren auf der nasschemischen Analyse einer Probe, Bohrmehl oder aufgemahlener Segmente eines Bohrkerns. Das Verfahren liefert einen Chloridgehalt je Tiefensegment, was mit einer starken Homogenisierung der Probe einhergeht, wodurch detaillierte Informationen zu Chloridunterschieden im Millimeterbereich verloren gehen. Eine alternative Methode ist die laserinduzierte Plasmaspektroskopie (LIBS), die nicht nur die quantitative ortsaufgelöste Bestimmung des Chloridgehalts im Bezug zur Zementmasse ermöglicht, sondern auch simultan detaillierte Informationen über die Verteilung vieler anderer chemischer Elemente liefert. Die räumliche Auflösung liegt in der Regel im Bereich von einigen Millimetern, kann aber bei Bedarf auf 0,1 mm oder weniger erhöht werden. Das neue Merkblatt B14 „Quantifizierung von Chlorid in Beton mit der laserinduzierten Plasmaspektroskopie (LIBS)“ der Deutschen Gesellschaft für Zerstörungsfreie Prüfungen (DGZfP) regelt und vereinheitlicht erstmals die zuverlässige und reproduzierbare Ermittlung des Chloridgehalts mit LIBS. In diesem Beitrag wird das Merkblatt vorgestellt und anhand praktischer Anwendungsbeispiele das Potenzial von LIBS für Fragestellungen in der Betonerhaltung verdeutlicht. KW - LIBS KW - Chlor KW - Chlorid KW - Beton KW - Bauwerksdiagnostik PY - 2024 DO - https://doi.org/10.1002/best.202400014 SP - 1 EP - 7 AN - OPUS4-60005 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Development of an online-analysis technique for the determina-tion of plant essential nutrients in soils using XRF and LIBS N2 - The main task of BAM in the I4S project is the development of online analytics for reliable monitoring of major and minor nutrients like K, P, Ca in soil using mobile-XRF (X-ray fluorescence spectroscopy) and mobile-LIBS (laser-induced breakdown spectroscopy). Each method provides fast and simultaneous multi-element analyses which are neccessary for mapping agricultural cropland. The first objective was to design a combined measurement setup for XRF and LIBS. The centerpiece is the rotatable sample plate which enables the measurement of moving samples. Current steps are the optimisation of the parameters for the analysis of soils. T2 - 12. Kolloquium Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - RFA KW - Agricultural KW - LIBS KW - Online KW - Soil KW - Monitoring PY - 2016 AN - OPUS4-38591 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Establishment of reference values for sensor based soil analysis N2 - Production of soil reference materials (for project partners) is integrated into the project „X-ray fluorescence, laser-induced breakdown spectroscopy (and Raman spectroscopy) as tools for a site-specific management of soil fertility“. BAM provides good analytics which is necessary for measuring the right values. Why is it important to have reference values? They enable the connection of own measuring results to the SI (international system of units) and the comparison with results from other laboratories. The soil reference materials are also needed for the calibration of the matrix dependent methods laser-induced breakdown spectroscopy (LIBS) and X-ray fluorescence analysis (XRF). For the production of soil reference materials different steps are required, for example drying, sieving and homogenisation. T2 - BonaRes Statusseminar CY - Leipzig, Germany DA - 14.11.2016 KW - LIBS KW - Reference KW - Homogenisation KW - Calibration KW - RFA KW - Soil PY - 2016 AN - OPUS4-38593 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Büchele, Dominique T1 - Mobile-XRF and -LIBS analysis of soils N2 - The main task of BAM in the I4S project is the development of online analytics for reliable monitoring of major and minor nutrients like K, P, Ca in soil using mobile-XRF (X-ray fluorescence spectroscopy) and mobile-LIBS (laser-induced breakdown spectroscopy). Each method provides fast and simultaneous multi-element analyses which are neccessary for mapping agricultural cropland. The first objective was to design a combined measurement setup for XRF and LIBS. The centerpiece is the rotatable sample plate which enables the measurement of moving samples. Current steps are the optimisation of the parameters for the analysis of soils. T2 - BonaRes Statusseminar CY - Leipzig, Germany DA - 14.11.2016 KW - RFA KW - Agricultural KW - LIBS KW - Online KW - Soil KW - monitoring PY - 2016 AN - OPUS4-38594 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd A1 - Gottlieb, Cassian A1 - Millar, Steven A1 - Wiggenhauser, Herbert T1 - Laser induced breakdown spectroscopy (LIBS) – automated 2D chemical analysis of concrete N2 - Laser-induced breakdown spectroscopy (LIBS) is a combination of laser ablation and optical emission spectroscopy. Due to the possibility of direct measurements on the sample surface with a minimum of sample preparation investigations of building materials can be conducted quite fast. In combination with a scanning technique (translation stage or scanning mirrors head) 2D element distributions of harmful species like chlorides and alkalis are evaluated with a sub-mm resolution. By scanning a surface of typically 100 mm x 100 mm the heterogeneity of the material may be considered. LIBS is capable to identify hot spots in element concentration with a resolution of 0.1 mm or even smaller. A LIBS-system for the on-site application on building materials is, in cooperation with system developers and companies which will use this technique for investigation on real structures, under test at BAM. We present an example. Further work will focus on providing guidelines to establish LIBS as a standard procedure for chemical investigations of building materials. T2 - NDE / NDT for Highway and Bridges: Structural Materials Technology CY - Portland, Oregon, USA DA - 29.08.2016 KW - LIBS KW - Concrete KW - Chloride KW - Chemical analysis PY - 2016 SN - 978-1-57117-392-8 SP - 155 EP - 160 PB - The American Society for Nondestructive Testing, Inc. CY - Columbus, OH 43228-0518, USA AN - OPUS4-37679 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, Cassian T1 - On-site carbon analysis of coal using a mobile LIBS system N2 - The information about the chemical composition of coal is of great interest during mining, sorting and processing. Due to great variations of the soil layers the quality of coal suffers great fluctuations during mining because of adjoining rocks [1-6]. To provide on-site analysis of coal the application of LIBS as a multi-element method has been tested. Therefore different qualities of coal have been chemically analyzed to get reference values for the water content as well as for the major (carbon) and minor components (ash = Ca, Mg, S, Si). For the LIBS analysis a system using a low energy laser with a wavelength of 1064 nm, pulse energy of 3 mJ, pulse length of 1.5 ns and a repetition rate of 100 Hz have been used. A compact czerny turner spectrometer operating in the UV range (Δλ = 170 nm – 350 nm) have been applied. To provide quantitative concentrations different calibration curves have been evaluated using chemometrics. The system has been validated using internal cross-validation as well as an external set of samples. For the evaluation of the method different figures of merit will be presented. After applying LIBS for coal analysis in the laboratory a LIBS system for the on-site analysis has been tested during the mining process. T2 - 9th International Conference on Laser Induced Breakdown Spectroscopy (LIBS2016) CY - Chamonix, Switzerland DA - 12.09.2016 KW - LIBS KW - On-site LIBS KW - Coal PY - 2016 AN - OPUS4-37420 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, Cassian T1 - 2D evaluation of heterogenous building materials using cluster algorithm N2 - In civil engineering the information about the quantitative ingress of harmful species like Cl⁻, Na⁺ and SO²⁻₄ is of great interest to evaluate the remaining life time of structures. These species are triggering different damage processes like the alkali-silica reaction (ASR) or the chloride-induced corrosion of the reinforcement. For the evaluation of the heterogeneous concrete it is necessary to discriminate between the different phases mainly cement matrix and aggregates. The transport processes are only proceeding in the cement matrix therefore the measured concentrations should be regarded to the cement content. For the 2D evaluation of element distributions different multivariate cluster-algorithms like k-means and Expectation-Maximization-algorithm (EM-algorithm) have been tested. The methods are compared and different figures of merit will be presented. After phase separation non-relevant information of the aggregates can be excluded. The ingress of harmful species is then quantified using chemometrics. Due to concrete cores from a parking deck the methods have been validated and verified with standard methods of wet-chemistry. T2 - 9th International Conference on Laser Induced Breakdown Spectroscopy (LIBS2016) CY - Chamonix, France DA - 12.09.2016 KW - LIBS KW - Building materials KW - Heterogeneity KW - Clustering PY - 2016 AN - OPUS4-37421 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen A1 - Büchele, Dominique A1 - Schmid, Thomas A1 - Ostermann, Markus T1 - Development of an online-analysis technique for the determination of plant essential nutrients in soils using XRF and LIBS N2 - Currently, there is almost no comprehensive mapping of agricultural cropland because of the lack of fast and affordable mapping methods for important soil properties. Arable land of some hectares in size show a broad range of different nutrient compositions. Because of this heterogeneity wrong fertilization can occur and can cause environmental pollution or lead to smaller harvests and this is simply a waste of resources. The goal of I4S (intelligence for soil) is to develop an integrated system for site-specific soil fertility management. The I4S consortium consists of 10 different institutions, which are testing various sensors for their suitability for the requested applications. Besides the preparation of reference materials, the main task of the Federal Institute for Materials Research and Testing (BAM) in this project is the method development for online-XRF (x-ray fluorescence spectroscopy) and for online-LIBS (laser-induced breakdown spectroscopy) sensor systems. Both methods have the advantage that there is no or only little sample preparation necessary. Each method provides a fast and simultaneous multi-element analysis. Both measurement setups can be utilized for a mobile application which is fundamental for reaching the goals of I4S. Having finally a set of some reference materials, further work will focus on the online-XRF and online-LIBS methods in order to obtain useable calibration models. The calibration models will then be tested using stationary and moving samples. T2 - 12. Kolloquium Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - RFA KW - LIBS KW - Soil KW - Agricultural KW - Online KW - Sensor system PY - 2016 SP - P12, 63 EP - 65 AN - OPUS4-38377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shabanov, Sergej V. A1 - Gornushkin, Igor B. T1 - Anions in laser-induced plasmas N2 - The equation of state for plasmas containing negative atomic and molecular ions (anions) is modeled. The model is based on the assumption that all ionization processes and chemical reactions are at local thermal equilibrium and the Coulomb interaction in the plasma is described by the Debye–Hu¨ckel theory. In particular, the equation of state is obtained for plasmas containing the elements Ca, Cl, C, Si, N, and Ar. The equilibrium reaction constants are calculated using the latest experimental and ab initio data of spectroscopic constants for the molecules CaCl2, CaCl, Cl2, N2, C2, Si2 , CN, SiN, SiC, and their positive and negative ions. The model is applied to laserinduced plasmas (LIPs) by including the equation of state into a fluid dynamic numerical model based on the Navier–Stokes equations describing an expansion of LIP plumes into an ambient gas as a reactive viscous flow with radiative losses. In particular, the formation of anions Cl-, C-, Si-, Cl2, Si2, C2 , CN-, SiC-, and SiN- in LIPs is investigated in detail. KW - Plasma modeling KW - Plasma KW - LIBS PY - 2016 DO - https://doi.org/10.1007/s00339-016-0175-8 VL - 2016 SP - Article Number: 676 PB - Applied Physics A, Springer AN - OPUS4-38771 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nagli, L. A1 - Gaft, M. A1 - Raichlin, Y. A1 - Gornushkin, Igor B. T1 - Cascade generation in Al laser induced plasma N2 - We found cascade IR generation in Al laser induced plasma. This generation includes doublet transitions 3s25s 2S1∕2→ 3s24p 2P1∕2,3∕2 → 3s24s 2S1∕2; corresponding to strong lines at 2110 and 2117 nm, and much weaker lines at 1312–1315 nm. The 3s25s2S 1∕2 starting IR generation level is directly pumped from the 3s23p 2P3∕2 ground level. The starting level for UV generation at 396.2 nm (transitions 3s24s 2S1∕2 → 4p 2P3∕2) is populated due to the fast collisional processes in the plasma plume. These differences led to different time and special dependences on the lasing in the IR and UV spectral range within the aluminum laser induced plasma. KW - Plasma diagnostics KW - Laser induced plasma KW - LIBS KW - Plasma modeling PY - 2018 DO - https://doi.org/10.1016/j.optcom.2018.01.041 VL - 415 SP - 127 EP - 129 PB - Elsevier B.V. AN - OPUS4-44274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Shabanov, Sergej V. T1 - Geometrical effects in data collection and processing for calibration-free laser-induced breakdown spectroscopy N2 - Data processing in the calibration-free laser-induced breakdown spectroscopy (LIBS) is usually based on the solution of the radiative transfer equation along a particular line of sight through a plasma plume. The LIBS data processing is generalized to the case when the spectral data are collected from large portions of the plume. It is shown that by adjusting the optical depth and width of the lines the spectra obtained by collecting light from an entire spherical homogeneous plasma plume can be leastsquare fitted to a spectrum obtained by collecting the radiation just along a plume diameter with a relative error of 10−11 or smaller (for the optical depth not exceeding 0.3) so that a mismatch of geometries of data processing and data collection cannot be detected by fitting. Despite the existence of such a perfect least-square fit, the errors in the line optical depth and width found by a data processing with an inappropriate geometry can be large. It is shown with analytic and numerical examples that the corresponding relative errors in the found elemental number densities and concentrations may be as high as 50% and 20%, respectively. Safe for a few found exceptions, these errors are impossible to eliminate from LIBS data processing unless a proper solution of the radiative transfer equation corresponding to the ray tracing in the spectral data collection is used. KW - Plasma KW - LIBS KW - Plasma modeling PY - 2017 DO - https://doi.org/10.1016/j.jqsrt.2017.09.018 SN - 0022-4073 SN - 1879-1352 VL - 204 SP - 190 EP - 205 PB - Elsevier CY - New York, NY AN - OPUS4-42287 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Application of LIBS for the chemical investigation of concrete infrastructure N2 - The majority of the built infrastructure is made of concrete, which is a multiphase system made of cement, aggregates, water and pores (every year nearly 4 billion tons of cement are produced which is largest mass flow generated by mankind). Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ett-ringite formation. For the standard procedure in civil engineering cores are taken, cut in slices, grinded and the obtained homogenized powder is solved in acid and investigated by standard procedures. BAM has developed the LIBS technique for the 2D evaluation of the chemical composition of concrete [1-5]. The technique is established for automated laborato-ry use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. LIBS is a surface technique. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measure-ment on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 μm, the consideration of the heterogeneity of the concrete and the possibility of automated measurements which save a lot of man-power and time. As an example the investigation of ingress profiles for standard diffusion and migration tests in civil engi-neering takes hours in comparison to just a few minutes using LIBS. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods. The state of the art of LIBS technique for applications in civil engineering will be presented, including typical results of 2D investigation of concrete in laboratory. The performance is also demonstrated by examples for on-site applications using a mobile LIBS system. The road map to standardization is presented as well. T2 - 9th Euro-Mediterranean Symposium on LIBS / Colloquium Spectroscopicum Internationale XL CY - Pisa, Italy DA - 12.06.2017 KW - ASR KW - LIBS KW - Concrete KW - Chlorid KW - Carbonation PY - 2017 AN - OPUS4-43194 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - SILAMARK – Qualitätssicherung einer Tiefenhydrophobierung vor-Ort N2 - Stahlbetonbauwerke der Verkehrsinfrastruktur sind nutzungsbedingt Expositionen ausgesetzt, die zu Schä-den an der Konstruktion führen können. Dabei ist in erster Linie die Einwirkung von tausalzhaltigen Wässern im Winter zu nennen, die durch den Beton kapillar und über Diffusionsvorgänge aufgenommen werden. Ein Weg, die kapillare Wasseraufnahme zu unterbinden, ist eine Tiefenhydrophobierung der Werkstoffoberflä-chen durch siliziumorganische Verbindungen. Die Wirksamkeit und die Dauerhaftigkeit dieser Tiefenhydro-phobierungen werden im Wesentlichen durch die Eindringtiefe und den Wirkstoffgehalt in der Betonrandzone bestimmt. Diese beiden Parameter gilt es also in der Qualitätssicherung zu überprüfen. Bisherige Verfahren zur Qualitätssicherung einer hydrophobierenden Maßnahme sind mit einer Bohrkernent-nahme verbunden, da die Analysen im Labor durchgeführt werden müssen. Andere Verfahren arbeiten zwar zerstörungsfrei und können am Objekt durchgeführt werden, liefern aber keine Informationen über die Ein-dringtiefe und die Wirkstoffverteilung. Das Fehlen eines geeigneten Qualitätssicherungs-Verfahrens hat eine breite praktische Anwendung der als technisch sehr leistungsfähig geltenden Tiefenhydrophobierungen bisher verhindert. Im Rahmen eines vom BMBF geförderten Forschungsvorhabens wurde ein Verfahren entwickelt mit dem direkt vor Ort das Vorhandensein der Tiefenhydrophobierung nachgewiesen und die Wirkstoffverteilung in der Betonrandzone detektiert werden kann. Da der chemische Kontrast einer Tiefenhydrophobierung zum Beton gering ist mussten „reaktive Marker“ entwickelt werden, die an das eigentliche Hydrophobierungsmittel chemisch gebunden wurden. Mit dem Verfahren der „Laser Induced Breakdown Spetroscopy“ (LIBS) konnte dann die Verteilung des als Marker verwendeten Elementes, und damit der Wirkstoffgehalt in der Betonrand-zone qualitativ und quantitativ bestimmt werden. Das Vorhaben SILAMARK wurde als Verbundprojekt unter Beteiligung der Sto SE & Co. KGaA, der Bundes-anstalt für Materialforschung und –prüfung, der Hochschule Karlsruhe – Technik und Wirtschaft (HsKa), der Aqua Stahl GmbH und der Specht Kalleja + Partner Beratende Ingenieure GmbH realisiert. T2 - Deutscher Beton- und Bautechnik-Verein E.V. Tag der Forschung CY - Berlin, Germany DA - 13.10.2017 KW - Beton KW - Tiefenhydrophobierung KW - LIBS KW - Dauerhaftigkeit PY - 2017 AN - OPUS4-43196 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - LIBS vom Labor zum Produkt (Laser induced Breakdown spectroscopy) N2 - Präsentation der Entwicklung des mobilen LIBS-Systems T2 - FA ZfP im Bauwesen der DGZfP CY - Berlin, Germany DA - 11.05.2017 KW - LIBS KW - Beton KW - Chlorid KW - Dauerhaftigkeit PY - 2017 AN - OPUS4-43198 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Application of laser-induced breakdown spectroscopy for the chemical investigation of concrete infrastructure N2 - The majority of the built infrastructure is made of concrete, which is a multiphase system made of cement, aggregates, water and pores (every year nearly 4 billion tons of cement are produced which is largest mass flow generated by mankind). Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ettringite formation. For the standard procedure in civil engineering cores are taken, cut in slices, grinded and the obtained homogenized powder is solved in acid and investigated by standard procedures. BAM has developed the LIBS technique for the 2D evaluation of the chemical composition of concrete [1-11]. The technique is established for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. LIBS is a surface technique. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete and the possibility of automated measurements which save a lot of manpower and time. As an example the investigation of ingress profiles for standard diffusion and migration tests in civil engineering takes hours in comparison to just a few minutes using LIBS. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods. Ingress of chlorides due to a crack in a repair mortar. Left: Photo of the cross section of a concrete core and the surface investigated by LIBS (area 70 mm x 70 mm). Right: Color coded chlorine intensity on the cross section of a concrete core, dark red represents high chlorine content. The state of the art of LIBS technique for applications in civil engineering will be presented, including typical results of 2D investigation of concrete in laboratory. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well. T2 - Optics and photonics international congress - Laser Solutions for Space and the Earth CY - Yokohama, Japan DA - 18.04.2017 KW - LIBS KW - Beton KW - On-site KW - Chloride PY - 2017 AN - OPUS4-43199 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Bestimmung von Nährstoffen in Böden mittels LIBS – Univariate vs. multivariate Datenanalyse N2 - LIBS (laserinduzierte Plasmaspektroskopie) ist bekannt für eine schnelle, simultane Multielementanalyse, welche kaum bis keine Probenvorbereitung benötigt. Im Hinblick dessen ist das Interesse an LIBS als Online-Analysentechnik für den Einsatz auf Agrarflächen in den letzten Jahren stark gestiegen. Im Rahmen des Projekts I4S (engl. für: intelligence for soil) soll mithilfe von LIBS der Elementgehalt von Makro- und Mikronährstoffen in Böden in Echtzeit bestimmt werden. I4S gehört zu den zehn interdisziplinären Forschungsprojekten des Innovationsprogramms BonaRes und arbeitet an der Entwicklung einer Sensorplattform für ein ortsspezifisches Management der Bodenfruchtbarkeit. BonaRes ist vom Bundesministerium für Bildung und Forschung (BMBF) gefördert und beschäftigt sich mit Boden als nachhaltige Ressource für die Bioökonomie. Für die Anwendung von LIBS an Böden wurde ein spezieller Aufbau konstruiert. Die Probenzufuhr erfolgt über einen drehbaren Probenteller, auf den der lose Boden in Form einer Spur aufgetragen oder als gepresste Tablette platziert werden kann. Der Probenteller kann in unterschiedlichen Geschwindigkeitsstufen betrieben werden, um die Anwendung auf dem Feld zu simulieren. Für eine höhere Signalintensität und eine bessere Reproduzierbarkeit wird eine Doppel-Puls (DP) Nd:YAG Lasereinheit verwendet. Weiterhin besitzt der LIBS-Messkopf eine integrierte Absaugvorrichtung, um bei dem Ablationsprozess entstehende Stäube zu minimieren und eine störungsfreie Detektion des Signals zu gewährleisten. Da es sich bei LIBS um eine Relativmethode handelt, muss das System für eine absolute Quantifizierung hinsichtlich der Zielanalyten kalibriert werden. Hierfür werden realitätsnahe Proben benötigt. Es wurden 16 freiverkäufliche, zertifizierte Referenzmaterialien gemessen und für die Kalibrierung verwendet. Aufgrund der komplexen Bodenmatrix und Einflüsse, wie Korngrößeneffekte und Feuchtigkeit, stellt die absolute Quantifizierung mittels LIBS eine Herausforderung dar. Für die Kalibrierung wurde sowohl ein univariater als auch ein multivariater Analyseansatz (Partial least square regression) verwendet. Mittels der multivariaten Auswertung konnte ein robusteres Kalibriermodell aufgrund einer besseren Korrelation zwischen Signalintensität und Elementkonzentration erstellt werden. Innerhalb des I4S-Verbundes gibt es eine Vielzahl von Bodenproben von unterschiedlichen Testackerflächen mit bereits bekannten Informationen über die chemische Zusammensetzung, Textur und Korngrößenverteilung. Diese Bodenproben sollen im nächsten Schritt für weitere Berechnungen und zu Validierungszwecken verwendet werden. T2 - 13. Herbstkolloqium AK Prozessanalytik CY - Esslingen, Germany DA - 20.11.2017 KW - Analyse KW - Nährstoffe KW - Boden KW - LIBS KW - Multivariat PY - 2017 AN - OPUS4-43151 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Determination of plant essential nutrients in soils using DP-LIBS N2 - LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. In the last few years there has been a growing interest in applications of LIBS in the field of agriculture. As part of the National Research Strategy BioEconomy 2030 the German Federal Ministry of Education and Research (BMBF) started an innovation programme called BonaRes. BonaRes consists of ten interdisciplinary research project associations which are dealing with soil as a sustainable resource for the bio-economy. One of these research projects is I4S (intelligence for soil) which has the goal to develop an integrated system for site-specific soil fertility management. This system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. The main task of LIBS measurements in this project is the real time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated. When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. With the help of 16 certified reference soils, calibration curves for different elements were initially calculated and used for the quantification of seven soil samples from different testing grounds in Germany. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, a calibration curve based on multivariate analysis (partial least square regression) was generated. T2 - Adlershof Forschungsforum CY - Berlin, Germany DA - 10.11.2017 KW - Fertility management KW - Multivariate KW - Soil KW - LIBS PY - 2017 AN - OPUS4-43154 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Entwicklung eines Online-LIBS-Systems für die Bestimmung von Nährstoffgehalten in Böden N2 - Die Gehalte von für das Pflanzenwachstum relevanten Nährstoffen divergieren innerhalb einer landwirtschaftlichen Nutzfläche sehr stark. Für eine ertragssteigernde Bewirtschaftung ist daher eine gezielte Düngung unabdingbar. Die Nachfrage nach einer kostengünstigen, flächendeckenden Kartierung von Ackerflächen in Bezug auf die im Boden enthaltenen Nährstoffe steigt demnach. Hierzu werden schnelle, mobil einsetzbare und verlässliche Messmethoden benötigt. Eine geeignete Methode stellt die laserinduzierte Plasmaspektroskopie (kurz: LIBS aus dem Englischen für laser-induced breakdown spectroscopy) dar. Die LIBS ermöglicht eine schnelle und simultane Multielementanalyse und ist dabei nahezu zerstörungsfrei. Des Weiteren bedarf es für die Analyse kaum bis keine Probenvorbereitung was den Einsatz auf dem Feld begünstigt. Die Methode beruht auf der Ionisierung des Probenmaterials (Plasmabildung) durch den Beschuss dieser mit kurzen Laserpulsen. Während der Expansion des Plasmas wird Strahlung emittiert, welche charakteristisch für die in der Probe enthaltenen Elemente ist. Das hier verwendete LIBS-System verfügt über einen Doppelpuls-Laser, bei dem zwei Laserpulse im kurzen Abstand hintereinander ausgesendet werden. Der erste Laserpuls ist für die “Vorbehandlung“ der Probe und der zweite Laserpuls für die Erwärmung des Plasmas. Dadurch können die Nachweisgrenzen im Vergleich zu einem einfach gepulsten Laser deutlich verbessert werden. Die Probenzufuhr findet durch einen drehbaren Probenteller statt auf dem der lose Boden in Form einer Spur aufgetragen wird. Der Probenteller kann in verschiedenen Geschwindigkeiten betrieben werden, um die Anwendung auf dem Feld zu simulieren. Da es sich bei der LIBS um eine Relativmethode handelt, ist eine Kalibrierung mit exakten Referenzwerten von verschiedenen Bodenproben notwendig. Böden weisen eine sehr komplexe Matrix auf, was die verlässliche Analyse mittels LIBS erschwert. Daher ist zunächst das Ziel die verschiedenen Messparameter des LIBS-Systems für unterschiedliche Böden zu optimieren und mögliche Störeffekte, wie Korngrößen und Feuchtigkeitsgrad, durch eine geeignete Probenkonditionierung zu eliminieren. T2 - Anakon 2017 CY - Tübingen, Germany DA - 03.04.2017 KW - Multivariat KW - Boden KW - LIBS KW - Nährstoffe KW - Analyse PY - 2017 AN - OPUS4-43157 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Hydrodynamic model of laser induced plasma including equilibrium chemistry N2 - Hydrodynamic model of laser induced plasma including plasma chemistry T2 - 6.07.2017, ITMO University, St. Petersburg, Russia CY - ITMO University, St. Petersburg, Russia DA - 5.07.2017 KW - Plasma KW - LIBS KW - Plasma modeling PY - 2017 AN - OPUS4-42294 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Predicting molecules in laser induced plasma based on equilibrium plasma model N2 - New development in modeling reactive flows in laser induced plasma T2 - 09.10.2017, SciX, Reno, NV, USA CY - Reno, NV, USA DA - 08.10.2017 KW - Laser induced plasma KW - LIBS KW - Plasma modeling PY - 2017 AN - OPUS4-42295 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shabanov, Sergej V. A1 - Gornushkin, Igor B. T1 - Geometrical effects in data collection and processing for calibration-free laser-induced breakdown spectroscopy N2 - Data processing in the calibration-free laser-induced breakdown spectroscopy (LIBS) is usually based on the solution of the radiative transfer equation along a particular line of sight through a plasma plume. The LIBS data processing is generalized to the case when the spectral data are collected from large portions of the plume. It is shown that by adjusting the optical depth and width of the lines the spectra obtained by collecting light from an entire spherical homogeneous plasma plume can be least-square fitted to a spectrum obtained by collecting the radiation just along a plume diameter with a relative error of 10 −11 or smaller (for the optical depth not exceeding 0.3) so that a mismatch of geometries of data processing and data collection cannot be detected by fitting. Despite the existence of such a perfect least-square fit, the errors in the line optical depth and width found by a data processing with an inappropriate geometry can be large. It is shown with analytic and numerical examples that the corresponding relative errors in the found elemental number densities and concentrations may be as high as 50% and 20%, respectively. Safe for a few found exceptions, these errors are impossible to eliminate from LIBS data processing unless a proper solution of the radiative transfer equation corresponding to the ray tracing in the spectral data collection is used. KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics PY - 2018 DO - https://doi.org/10.1016/j.jqsrt.2017.09.018 SN - 0022-4073 SN - 1879-1352 VL - 204 SP - 190 EP - 205 PB - Elsevier AN - OPUS4-43131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Improved algorithm for calibration-free laser induced breakdown spectroscopy N2 - An improved algorithm for calibration-free laser induced breakdown spectroscopy (CF LIBS) will be presented which includes several novel features in comparison with previously proposed similar algorithms. In particular, it allows using spectral lines with arbitrary optical thickness for the construction of Saha-Boltzmann plots, retrieves the absorption path length (plasma diameter) directly from a spectrum, replaces the Lorentzian line profile function by the Voigt function, and allows for self-absorption correction using pre-calculated and tabulated data rather than approximating functions. The tabulated data embody the solutions of the radiative transfer equation for numerous combinations of optical thicknesses and line widths. The algorithm is thoroughly verified using synthetic spectra. T2 - LIBS 2018 at SciX 2018 CY - Atlanta, GA, USA DA - 21.10.2018 KW - Plasma diagnostics KW - Laser induced plasma KW - LIBS KW - Plasma modeling PY - 2018 AN - OPUS4-46930 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gulikers, J. A1 - Millar, Steven A1 - Wilsch, Gerd T1 - Practical application of Laser Induced Breakdown Spectroscopy for determinafion of the chioride content in concrete structures N2 - This paper will address the relevance of chloride measurements in practice for durability condition assessment and a description of the working principle of LIBS will be given. Examples of chloride profiles obtained by the common wet chemical analysis will be shown and compared with results from LIBS measurements as to demonstrate the accuracy of the LIBS-technique. The latter will be supported by clear graphs. In addition examples on the extra information resulting from measurements performed with LIBS for improvement of condition assessment and prediction will be shown. T2 - CONFERENCE IN HONOR OF Centennial of LABORATORY OF CONSTRUCTION MATERIALS CY - Lausanne, Switzerland DA - 19.08.2018 KW - LIBS KW - Concrete KW - Chloride KW - Condition assesment PY - 2018 SP - 80 EP - 83 CY - Lausanne AN - OPUS4-47108 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gulikers, J. T1 - Practical application of Laser Induced Breakdown Spectroscopy for determination of the chloride content in concrete structures N2 - The relevance of chloride measurements in practice for durability condition assessment and a description of the working principle of LIBS will be given. A comparison of chloride profiles obtained by the common wet chemical analysis and results from LIBS measurements are shown to demonstrate the accuracy of the LIBS-technique. In addition, an example on the extra information resulting from measurements performed with LIBS for improvement of condition assessment and prediction will be shown. T2 - Conference celebrating the Laboratory of Construction Materials (EPFL) Centennial CY - Lausanne, Switzerland DA - 19.08.2018 KW - LIBS KW - Concrete KW - Chlorride KW - Condition assesment PY - 2018 AN - OPUS4-47109 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Alternative Möglichkeiten zur Bestimmung der Chlorid-Migration in Parkhausbauten (LIBS) N2 - Vorstellung von LIBS. Demonstration der Möglichkeiten zur Untersuchung des Chlorid-Gehaltes im Beton in Parkbauten. Darstellung von Praxisbeispielen zur Bestimmung des Zustandes eines Parkhauses. T2 - Fachtagung "Parkhäuser und Tiefgaragen" CY - Hamburg, Germany DA - 27.11.2018 KW - LIBS KW - Beton KW - Chlorid KW - Parkbauten KW - Qualitätssicherung PY - 2018 AN - OPUS4-47114 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sankat, Nina A1 - Wilsch, Gerd A1 - Gottlieb, Cassian A1 - Millar, Steven T1 - Analysis of concrete structures using Laser-Induced Breakdown Spectroscopy N2 - The Laser-Induced Breakdown Spectroscopy (LIBS) is a laser spectroscopic method which allows a time efficient, minor-destructive, chemical analysis of materials. In principle all elements on the periodic table can be simultaneously analysed by using LIBS, regardless of the state of aggregation. LIBS offers numerous applications in the field of civil engineering; most importantly the analysis of building materials. This work will focus on the evaluation of concrete structures and harmful substances which can penetrate the concrete. A variety of information can be collected through LIBS. Determining the concentration of harmful substances like chloride, sodium or sulphur, the examination of the carbonation depth and the distinction between varying layers of materials (e.g. aggregates, cement paste, metals, etc.) are possible applications. All this information can be provided through one LIBS measurement in the form of a high resolution 2D element map, with resolutions up to 0.1 mm x 0.1 mm. To scan a concrete surface only an optical access is needed. To create a depth profile of an intruding substance the extraction of a drill core is necessary. Onsite measurements via LIBS can be conducted by using a mobile version of the LIBS system. Through using calibration curves LIBS allows not only the qualitative but also quantitative analysis of element concentrations. All those prospects make LIBS a trendsetting method to secure the integrity of infrastructures in a sustainable manner. A variety of examples which show the performance and results of LIBS analysis will be presented. T2 - CoMS 2017 CY - Zadar, Croatia DA - 19.04.2017 KW - Testing method KW - Concrete KW - LIBS KW - Harmful substances PY - 2017 SN - 978-953-8168-04-8 VL - 1 SP - 334 EP - 340 AN - OPUS4-42630 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sankat, Nina T1 - Analysis of concrete structures using Laser-Induced Breakdown Spectroscopy N2 - The Laser-Induced Breakdown Spectroscopy (LIBS) is a laser spectroscopic method which allows a time efficient, minor-destructive, chemical analysis of materials. In principle all elements on the periodic table can be simultaneously analysed by using LIBS, regardless of the state of aggregation. LIBS offers numerous applications in the field of civil engineering; most importantly the analysis of building materials. This work will focus on the evaluation of concrete structures and harmful substances which can penetrate the concrete. A variety of information can be collected through LIBS. Determining the concentration of harmful substances like chloride, sodium or sulphur, the examination of the carbonation depth and the distinction between varying layers of materials (e.g. aggregates, cement paste, metals, etc.) are possible applications. All this information can be provided through one LIBS measurement in the form of a high resolution 2D element map, with resolutions up to 0.1 mm x 0.1 mm. To scan a concrete surface only an optical access is needed. To create a depth profile of an intruding substance the extraction of a drill core is necessary. Onsite measurements via LIBS can be conducted by using a mobile version of the LIBS system. Through using calibration curves LIBS allows not only the qualitative but also quantitative analysis of element concentrations. All those prospects make LIBS a trendsetting method to secure the integrity of infrastructures in a sustainable manner. T2 - CoMS 2017 CY - Zadar, Croatia DA - 19.04.2017 KW - Testing method KW - LIBS KW - Concrete KW - Harmful substances PY - 2017 AN - OPUS4-42632 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilsch, Gerd T1 - Fast Quantitative Chemical Analysis of Cencrete using LIBS N2 - Non-destructive testing of concrete based on laser induced breakdown spectroscopy in civil engineering. KW - LIBS KW - Concrete KW - Chloride PY - 2017 SP - 289 EP - 325 CY - Berlin, Germany AN - OPUS4-42648 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pignatelli, Giuseppe T1 - Effects of nanoparticles on laser ablation N2 - Introduction: Laser Induced Breakdown Spectroscopy (LIBS) is an atomic emission analytical technique, wide spreading in laboratories and industries. One way to dramatically increase its analytical results is to deposit metal NPs on the sample surface, resulting in an better version called Nanoparticle Enhanced LIBS (NELIBS). In order to better know and use this technique, the evolution of the plasma has been studied with Tomography. T2 - CHESS 2017 CY - Florence, Italy DA - 27.11.2017 KW - LIBS KW - Nanoparticles PY - 2017 AN - OPUS4-43476 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völker, Tobias T1 - Application of two calibration-free LIBS techniques N2 - Two calibration-free (CF) LIBS approaches are used for the quantitative analysis of cement samples: the CF-LIBS based on the Boltzmann plot method and the Monte Carlo (MC) LIBS based on the iterative spectrum fitting. In CF-LIBS, the inverse problem is solved, i.e. the elemental concentrations are determined by the reconstruction of plasma parameters from spectra. The MC-LIBS technique solves the direct problem by finding the highest correlation between the model-generated and experimental spectrum. The accuracy of both calibration-free LIBS methods suffers from factors such as inaccurately determined instrumental function, the deviation of experimental plasma from the mathematical model used, not taking into account the collection geometry, and from the uncertainty of spectroscopic data. The both calibration-free LIBS approaches are first applied to synthetic spectra which perfectly suit the mathematical model of the method, i.e. the model of the uniform, isothermal, and stationary plasma. This test yields the accuracy of both the approaches for the ideal case. In addition, the accuracy of both the methods is investigated for non-uniform and non-isothermal plasma, because real laser-induced plasma often has high gradients in temperature and particle number densities. Finally, both calibration-free LIBS approaches are applied to experimental spectra obtained from cement samples. The figures of merits of two approaches are compared when working with both synthetic and experimental spectra. T2 - LIBS 2018 at SciX 2018 CY - Atlanta, GA DA - 21.10.2018 KW - Plasma diagnostics KW - Laser induced plasma KW - LIBS KW - Plasma modeling PY - 2018 AN - OPUS4-46931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd A1 - Gottlieb, Cassian A1 - Günther, Tobias A1 - Millar, Steven ED - Forde, Mike T1 - Application of laser induced breakdown spectroscopy N2 - A big part of the infrastructure is made of concrete, which is a multiphase system made of cement, aggregates, water and pores. Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. In addition, the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from deicing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulphates may cause spalling of the concrete surface due to ettringite formation. For the standard procedure in civil engineering cores are taken, cut in slices, grinded and the obtained homogenized powder is solved in acid and investigated by standard procedures. BAM has developed the LIBS technique for the 2D evaluation of the chemical composition of concrete. The technique is established for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2 , SO4 2-and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. LIBS is a surface technique. To get information about the ingress depth, a drill core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete and the possibility of automated measurements which save a lot of manpower and time. As an example the investigation of ingress profiles for standard diffusion and migration tests in civil engineering takes hours in comparison to just a few minutes using LIBS. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods. The state of the art of LIBS technique for applications in civil engineering will be presented, including typical results of 2D investigation of concrete in laboratory. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well. T2 - Structural Faults + Repair-2018 CY - Edinburgh, UK DA - 15.05.2018 KW - Sulphate KW - Chloride KW - Concrete KW - LIBS PY - 2018 SN - 0-947644-86-5 DO - https://doi.org/10.25084/sfr.2018.0030 SP - 1 EP - 7 PB - University of Edinburgh CY - Edinburgh AN - OPUS4-46947 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Application of LIBS for the chemical investigation of concrete infrastructure N2 - Overview about LIBS applications in civil engineering T2 - Structural Faults + Repair-2018 CY - Edinburgh, UK DA - 15.05.2018 KW - On-site measurements KW - LIBS KW - Concrete KW - Chloride KW - Sulfates PY - 2018 AN - OPUS4-46948 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Günther, Tobias T1 - Boosting of chlorine emission by electric discharge reheating in laser-induced plasma N2 - For the determination of the remaining life-time and the degree of damage of reinforced concrete structures such as marine construction, bridges or parking decks, a highly precise measurement of harmful species is also required for trace elements. One of the most interesting elements is chlorine, because above a certain threshold corrosion is triggered. To increase the intensity of the chlorine line, helium is usually used, which is costly. To overcome this problem, low electrical discharge reheating is used which operates in air atmosphere. A comparison between results obtained by measuring with helium and reheating by electrical discharge is presented. The performance is compared by the resulting calibration curves and the calculated limit of detection obtained by 15 reference samples based on cement with NaCl. Concentrations of reference samples range from 0.05 to 2.5 wt% chlorine. T2 - Xth international conference on Laser-Induced Breakdown Spectroscopy CY - Atlanta, GA, USA DA - 21.10.2018 KW - LIBS KW - Electric discharge KW - Plasma reheating PY - 2018 AN - OPUS4-46792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, Cassian T1 - Temporal evaluation and imaging of laser-induced plasmas on cement-based materials N2 - In civil engineering, the laser-induced breakdown spectroscopy has been applied as a fast and reliable method for a quantitative evaluation of concrete cores. Due to a two-dimensional scanning, the heterogeneity of concrete can be evaluated and elements like Cl, Na, and S are related to the cement matrix only. This study deals with the temporal evaluation and imaging of laser-induced plasmas on cement-based materials, in order to investigate the impact of aggregates with diffrent grain size on the spectral response in LIBS. T2 - Xth international conference on Laser-Induced Breakdown Spectroscopy CY - Atlanta, GA, USA DA - 21.10.2018 KW - LIBS KW - Concrete KW - Grain size PY - 2018 AN - OPUS4-46794 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Günther, Tobias T1 - Plasma reheating in LIBS with electric discharge to detect halogens in low concentrations N2 - The Laser-induced Breakdown Spectroscopy (LIBS) is an useful analytical technique for the chlorine detection in building materials, specifically in the reinforcement concrete. If chlorine exceeds a specific concentration threshold, the result can be pitting corrosion of the reinforcement, which affects the stability and lifetime of building structures like marine constructions, bridges or parking decks. The critical chlorine content based to cement is 0.4 wt.-% based to the cement for reinforced concrete. The ingress of chlorides from sea water or de-icing salt leads to corrosion of the reinforcement. The chlorine spectral line Cl I at 837.59 nm shows a good performance in helium atmosphere. For measurements without helium we used a electric discharge setup to reheat the Laser-induced plasma with a voltage below 100 V. In this case the reheating shows an increasing chlorine emission in air atmosphere. This work shows chlorine calibration curves with LIBS in a helium flow and LIBS with electric discharge reheating in air atmosphere. The determination of the limit of detection (LOD) for both setups and the measurement results of a drill core sample with a quantitative chlorine ingress profile will be presented. T2 - Xth international conference on Laser-Induced Breakdown Spectroscopy CY - Atlanta, GA, USA DA - 21.10.2018 KW - LIBS KW - Laser induced plasma KW - Plasma reheating KW - Electric discharge PY - 2018 AN - OPUS4-46797 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völker, Tobias T1 - Application of two calibration-free LIBS techniques for synthetic spectra of cement samples N2 - Two calibration-free LIBS techniques are used for the quantitative analysis of synthetic cement samples: the CF-LIBS based on the Boltzmann plot method and the Monte Carlo (MC) LIBS based on the iterative spectrum fitting. In CF-LIBS, the inverse problem is solved, i.e. the elemental concentrations are determined by the reconstruction of plasma parameters from spectra. The MC-LIBS technique solves the direct problem by finding the highest correlation between the model-generated and experimental spectrum. The accuracy of both calibration-free LIBS methods suffers from factors such as inaccurately determined instrumental function, the deviation of experimental plasma from the mathematical model used, not taking into account the collection geometry and from the uncertainty of spectroscopic data. Therefore, the both calibration-free LIBS approaches are applied to synthetic spectra which perfectly suit the mathematical model of the method. This test yields the accuracy of both the approaches for the ideal case. In addition, the accuracy of both methods is investigated for non-isothermal plasma, because real laser-induced plasma often has high gradients in temperature. Both methods assume an isothermal plasma. T2 - Xth international conference on Laser-Induced Breakdown Spectroscopy CY - Atlanta, GA, USA DA - 21.10.2018 KW - Cement KW - MC-LIBS KW - LIBS KW - CF-LIBS PY - 2018 AN - OPUS4-46774 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Schnelle quantitative Untersuchung der Elementverteilungen im Beton mittels LIBS N2 - Die Laserinduzierte Plasmaspektroskopie (engl.: Laser-induced Breakdown Spectroscopy, kurz: LIBS) ist eine Kombination aus Laserablation mittels eines energiereichen Laser-Pulses, der Erzeugung eines Plasmas auf der zu untersuchenden Oberfläche und dem quantitativen Nachweis der Elementzusammensetzung durch spektroskopische Untersuchung der vom Plasma emittierten Strahlung. Ein LIBS-Gerät liefert dem sachkundigen Planer Daten für die Bewertung des Ist-Zustandes von Bauwerken unserer Infrastruktur durch die zweidimensionale Erfassung von Elementverteilungen. Typische Anwendungen sind die Erfassung von Chlor, Schwefel, Kohlenstoff, Natrium, Kalium und Lithium in Beton oder als – Qualitätssicherung – der Nachweis der mit einem Marker versehenen Tiefenhydrophobierung. In Zusammenarbeit zwischen Industriepartnern und der BAM wurden ein Labor und ein mobiles LIBS-System für die Vor-Ort-Messungen entwickelt. Die Analyse erfolgt vollautomatisch. Die Ortsauflösung beträgt bis zu 0,1 mm x 0,1 mm. Es können Messflächen von 140 mm x 170 mm gescannt werden. Die Erstellung von 2D-Elementverteilungen im Beispiel unten benötigt weniger als 10 Minuten. T2 - ibausil - 20. Internationale Baustofftagung CY - Weimar, Germany DA - 12.09.2018 KW - LIPS KW - Chlorid KW - LIBS KW - Beton PY - 2018 AN - OPUS4-46778 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Fast quantitave chemical analysis of concrete using LIBS N2 - Overview about LIBS applications for investigation of building materials. T2 - NDT&E Advanced Training Workshop CY - Berlin, Germany DA - 27.06.2018 KW - LIBS KW - Concrete KW - Damage processes KW - Chlorid KW - Sulfate KW - Alkalies PY - 2018 AN - OPUS4-46821 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Application of LIBS for the chemical investigation of concrete infrastructure N2 - Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ettringite formation. BAM has developed the LIBS technique for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete. The possibility of automated measurements saves a lot of manpower and time. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods. Typical results of 2D investigation of concrete in laboratory will be presented. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well. T2 - 12th ECNDT CY - Gothenburg, Sweden DA - 11.06.2018 KW - LIBS KW - Concrete KW - Chloride KW - Sulfates KW - Heterogeneity PY - 2018 AN - OPUS4-46828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd A1 - Gottlieb, Cassian A1 - Günther, Tobias A1 - Völker, Tobias ED - Ludwig, H.-M. T1 - Schnelle quantitative Untersuchung von Elementverteilungen in Beton mittels LIBS N2 - Die Laserinduzierte Plasmaspektroskopie (engl.: Laser-induced Breakdown Spectroscopy, kurz: LIBS) ist eine Kombination aus Laserablation mittels eines energiereichen Laser-Pulses, der Erzeugung eines Plasmas auf der zu untersuchenden Oberfläche und dem quantitativen Nachweis der Elementzusammensetzung durch spektroskopische Untersuchung der vom Plasma emittierten Strahlung. Ein LIBS-Gerät liefert dem sachkundigen Planer Daten für die Bewertung des Ist-Zustandes von Bauwerken unserer Infrastruktur durch die zweidimensionale Erfassung von Elementverteilungen. Typische Anwendungen sind die Erfassung von Chlor, Schwefel, Kohlenstoff, Natrium, Kalium und Lithium in Beton oder als – Qualitätssicherung – der Nachweis der mit einem Marker versehenen Tiefenhydrophobierung. In Zusammenarbeit zwischen Industriepartnern und der BAM wurden ein Labor und ein mobiles LIBS-System für die Vor-Ort-Messungen entwickelt. Die Analyse erfolgt vollautomatisch. Die Ortsauflösung beträgt bis zu 0,1 mm x 0,1 mm. Es können Messflächen von 140 mm x 170 mm gescannt werden. Die Erstellung von 2D-Elementverteilungen im Beispiel unten benötigt weniger als 10 Minuten. T2 - ibausil - 20. Internationale Baustofftagung CY - Weimar, Germany DA - 12.09.2018 KW - LIPS KW - LIBS KW - Beton KW - Chlorid PY - 2018 SN - 978-3-00-059950-7 VL - 2 SP - 2380 EP - 2387 PB - F.A. Finger-Institut für Baustoffkunde, CY - Weimar AN - OPUS4-46779 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Application of LIBS for the chemical investigation of concrete infrastructure N2 - The majority of the built infrastructure is made of concrete, which is a multiphase system made of cement, aggregates, water and pores. Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ettringite formation. For the standard procedure in civil engineering cores are taken, cut in slices, grinded and the obtained homogenized powder is solved in acid and investigated by standard procedures. BAM has developed the LIBS technique for the 2D evaluation of the chemical composition of concrete [1-11]. The technique is established for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. LIBS is a surface technique. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete and the possibility of automated measurements which save a lot of manpower and time. As an example the investigation of ingress profiles for standard diffusion and migration tests in civil engineering takes hours in comparison to just a few minutes using LIBS. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods. Ingress of chlorides due to a crack in a repair mortar. Left: Photo of the cross section of a concrete core and the surface investigated by LIBS (area 70 mm x 70 mm). Right: Color coded chlorine intensity on the cross section of a concrete core, dark red represents high chlorine content. The state of the art of LIBS technique for applications in civil engineering will be presented, including typical results of 2D investigation of concrete in laboratory. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well. T2 - ICCRRR2018, 5th international conference on Concrete Repair, Rehabilitation and Retrofitting CY - Cape Town, South Africa DA - 19.11.2018 KW - LIBS KW - Chlorid KW - Alkalies KW - Concrete KW - Damage PY - 2018 AN - OPUS4-46781 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - Detection of ion ingress by LIBS for Evaluation of the remaining lifetime of a concrete structure N2 - The majority of the built infrastructure is made of concrete, which is a multiphase system made of cement, aggregates, water and pores. Concrete is often used in combination with steel as reinforced concrete. Environmental influences, especially the ingress of harmful ions in combination with the ingress of water, trigger different damage processes which reduce the designed lifetime of a structure. The ingress of chlorides from de-icing salt or sea water leads to corrosion of the reinforcement. Also the carbonation of the concrete may trigger the corrosion of the reinforcement. The ingress of alkalis from de-icing salts may cause the expansion of the amorphous silica aggregates (alkali-silica reaction) through formation of a swelling gel of calcium silicate hydrate if water is present. The ingress of sulfates may cause spalling of the concrete surface due to ettringite formation. For the standard procedure in civil engineering cores are taken, cut in slices, grinded and the obtained homogenized powder is solved in acid and investigated by standard procedures. BAM has developed the LIBS technique for the 2D evaluation of the chemical composition of concrete [1-11]. The technique is established for automated laboratory use with high numbers of samples to investigate transport processes of harmful species (Cl-, CO2, SO42- and alkalis) in concrete. Information about ingress depth and the quantitative values are important to estimate the remaining lifetime of the infrastructure. LIBS is a surface technique. To get information about the ingress depth, a core has to be taken and cut in the middle. The measurements are carried out at the cross section. The main advantages of LIBS are the direct measurement on the surface of the concrete, fast analysis (sample rate 100 Hz) with a spatial resolution of up to 100 µm, the consideration of the heterogeneity of the concrete and the possibility of automated measurements which save a lot of manpower and time. As an example the investigation of ingress profiles for standard diffusion and migration tests in civil engineering takes hours in comparison to just a few minutes using LIBS. At the same time a 2D-evaluation provides information about hot spots of elemental concentration which may not be found by standard methods. Ingress of chlorides due to a crack in a repair mortar. Left: Photo of the cross section of a concrete core and the surface investigated by LIBS (area 70 mm x 70 mm). Right: Color coded chlorine intensity on the cross section of a concrete core, dark red represents high chlorine content. The state of the art of LIBS technique for applications in civil engineering will be presented, including typical results of 2D investigation of concrete in laboratory. The performance is also demonstrated by examples for onsite applications using a mobile LIBS system. The road map to standardization is presented as well. T2 - ASNT SMT/NDT-CE 2018 CY - New Brunswick, NJ, USA DA - 27.08.2018 KW - Damage processes KW - LIBS KW - Concrete KW - Chloride PY - 2018 AN - OPUS4-46782 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völker, Tobias T1 - Quantitative on-site analysis of harmful elements in building structures with a mobile LIBS-System N2 - Environmental influences and damage processes drastically reduce the durability of concrete and reinforced concrete structures. Much of this damage can be traced back to the penetration of harmful elements into the concrete. These elements cause damage processes such as the chlorine-induced corrosion, the alkali-silica reaction or the carbonization. For the maintenance the knowledge of the element concentration and the penetration depth of these harmful elements is essential. Based on this data, a maintenance concept can be developed and an estimation of the remaining service life-time can be carried out. Typically, chemical analyzes are used to determine harmful elements in concrete, which are costly and time consuming. As an alternative method LIBS is used. On-site measurements were carried out with a mobile LIBS-System to determine harmful elements in a parking garage. A scanner is used to obtain a two-dimensional element mapping. For the quantitative analysis, a calibration of the system is carried out with 15 reference samples based on cement with NaCl with a concentration range of chlorine of 0.05 to 2.5 wt.%. To determine the penetration profile of the harmful element chlorine, concrete cores were drilled, split and analyzed directly on-site. T2 - Xth international conference on Laser-Induced Breakdown Spectroscopy CY - Atlanta, GA, USA DA - 21.10.2018 KW - LIBS KW - Mobile-LIBS KW - On-site analysis KW - Concrete PY - 2018 AN - OPUS4-46790 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Günther, Tobias T1 - Spatially resolved determination of chloride content on rough surfaces using LIBS N2 - The durability and the lifetime of reinforced concrete structures can be drastically reduced by the influence of damage processes. One of the most common causes is chloride-induced corrosion, which is triggered by increased chloride content near the reinforcement. In a study, the chloride content should be determined directly at corrosion areas. The LIBS system used consists of a micro-chip laser (3 mJ, 100 Hz, 1.5ins) and two compact spectrometers covering the wavelength range of 177-355 nm (UV) and 750-940 nm (NIR). The analysis of the chloride content was carried out via the atomic chlorine spectral line 837.59 nm, using helium for signal amplification. Calibrations were carried out for quantitative chlorine measurements with 15 reference samples in the working range of 0.05 to 6.00 wt% chlorine. The calibration of the LIBS system was done according to DIN 32 645 and was tested for linearity. The determination of the quantitative chlorine contents was carried out on samples which were broken and thus have a high surface roughness. This requires real time correction of the focus point to compensate for the roughness of the samples. The poster shows spatially resolved element distributions and determined quantitative chloride concentrations near the corrosion Areas. T2 - Xth international conference on Laser-Induced Breakdown Spectroscopy CY - Atlanta, GA, USA DA - 21.10.2018 KW - LIBS KW - Rough surface KW - Chloride PY - 2018 AN - OPUS4-46791 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - LIBS - Ein Tool zur Untersuchung der chemischen Zusammensetzung von Beton N2 - Die „Laser Induced Breakdown Spectroscopy“ (LIBS) bietet die Möglichkeit, direkt auf der optisch zugänglichen Oberfläche von Baustoffen 2-dimensional die Elementverteilung zu erfassen. Durch das zugrundeliegende Prinzip sind alle Elemente des Periodensystems detektierbar, auch leichte Elemente wie Wasserstoff oder Lithium. Einerseits können alle für die Zusammensetzung des Zementes und der Gesteinskörnung relevanten Elemente erfasst werden, andererseits auch die für Schädigungsprozesse in Beton wichtigen Elemente Chlor, Schwefel, Natrium, Kalium, Kohlenstoff und Stickstoff. Der Nachweis kann simultan erfolgen. Der Vorteil des Verfahrens liegt in der einfachen Probenvorbereitung, der direkten Messung auf der Oberfläche des Festkörpers und der Schnelligkeit der Messung. Die Heterogenität von Beton wird im Ergebnis berücksichtigt. Die Konzentrationen von schädigenden Ionen lassen sich bezogen auf den Bindemittelgehalt angeben. LIBS liefert standardmäßig qualitative Werte. Durch Kalibrierung anhand von Referenzproben ist eine Quantifizierung der Ergebnisse möglich. Das Potenzial des Verfahrens wird am Beispiel der Bestimmung der Chlorid-Verteilung in der Bindemittelmatrix vorgestellt. Andere Anwendungen sind die Bestimmung der Karbonatisierungstiefe, die Bestimmung des Eintrages von Alkalien oder die Bestimmung der Verteilung von Schwefel. Das Verfahren kann im Labor zur Untersuchung einer großen Anzahl von Proben oder vor-Ort zur schnellen Entscheidungsfindung eingesetzt werden. Kommerzielle Geräte sind seit kurzem verfügbar. Die örtliche Auflösung der Messung beträgt bis zu 0,1 mm × 0,1 mm. Ein Messpunkt hat einen Durchmesser von ca. 100 μm. Die Messfrequenz liegt bei 100 Hz. Als Ergebnis entstehen für jedes Element eine 2D-Darstellungen der Konzentration über der Messfläche. Der Scan eines Bohrkerns von 50 mm x 70 mm dauert bei einer Auflösung von 0,5 mm lateral und 1 mm vertikal ca. 7 min. Es können auch raue oder gebrochene Oberflächen durch Nachführung der z-Achse untersucht werden. Die Nachweisgrenze für die Bestimmung des Chlorgehaltes bezogen auf den Bindemittelgehalt liegt bei 0,03 M-%. Der Unterausschuss LIBS im Bauwesen im FA ZfP im Bauwesen der DGZfP arbeitet an der Erstellung von Merkblättern und Regelwerken zur Anwendung des Verfahrens. T2 - Bauwerksdiagnose 2018 CY - Berlin, Germany DA - 15.02.2018 KW - Alkalien KW - LIBS KW - Beton KW - Schädigung KW - Chlorid KW - Sulfat PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-468076 UR - https://www.ndt.net/search/docs.php3?id=22621 AN - OPUS4-46807 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd T1 - LIBS - Ein Tool zur Untersuchung der chemischen Zusammensetzung von Beton N2 - Dargestellt werden die Möglichkeiten von LIBS zur Untersuchung von Baustoffen und aktuelle Anwendungsbeispiele. T2 - LIBS Seminar - Immer wissen was drin ist CY - Telow, Germany DA - 28.06.2018 KW - Alkalien KW - LIBS KW - Beton KW - Schädigung KW - Chloride KW - Sulfate PY - 2018 AN - OPUS4-46820 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Yuan, Huan A1 - Gornushkin, Igor B. A1 - Gojani, Ardian A1 - Wang, X. H. A1 - Rong, Ming Zhe T1 - Laser-induced plasma imaging for low-pressure detection N2 - A novel technique based on laser induced plasma imaging is proposed to measure residual pressure in sealed containers with transparent walls, e.g. high voltage vacuum interrupter in this paper. The images of plasma plumes induced on a copper target at pressure of ambient air between 10−2Pa and 105Pa were acquired at delay times of 200ns, 400ns, 600ns and 800ns. All the plasma images at specific pressures and delay times showed a good repeatability. It was found that ambient gas pressure significantly affects plasma shape, plasma integral intensities and expansion dynamics. A subsection characteristic method was proposed to extract pressure values from plasma images. The method employed three metrics for identification of high, intermediate and low pressures: the distance between the target and plume center, the integral intensity of the plume, and the lateral size of the plume, correspondingly. The accuracy of the method was estimated to be within 15% of nominal values in the entire pressure range between 10−2Pa and 105Pa. The pressure values can be easily extracted from plasma images in the whole pressure range, thus making laser induced plasma imaging a promising technique for gauge-free pressure detection. KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics PY - 2018 DO - https://doi.org/10.1364/OE.26.015962 SN - 1094-4087 VL - 26 IS - 12 SP - 15962 EP - 15971 PB - Optical Society of America under the terms of the OSA Open Access Publishing Agreement AN - OPUS4-45219 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Völker, Tobias A1 - Kazakov, Alexander Ya. T1 - Extension and investigation by numerical simulations of algorithm for calibration-free laser induced breakdown spectroscopy N2 - Accuracy of calibration-free (CF) methods in laser-induced breakdown spectroscopy (LIBS) depends on experimental conditions and instrumental parameters that must match a CF LIBS model. Here, the numerical study is performed to investigate effects of various factors, such as the optical density, plasma uniformity, line overlap, noise, spectral resolution, electron density and path length on the results of CF-LIBS analyses. The effects are examined one-by-one using synthetic spectra of steel slag samples that fully comply with the mathematical model of the method. Also, the algorithm includes several new features in comparison with previously proposed CF algorithms. In particular, it removes limits on the optical thickness of spectral lines that are used for the construction of the Saha-Boltzmann plot; it retrieves the absorption path length (Plasma diameter) directly from spectral lines; it uses the more realistic Voigt line profile function instead of the Lorentzian function; and it employs the pre-calculated and tabulated thin-to-thick line ratios instead of approximating functions for selfabsorption correction. KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics KW - Calibration free LIBS PY - 2018 DO - https://doi.org/10.1016/j.sab.2018.06.011 SN - 0584-8547 VL - 147 SP - 149 EP - 163 PB - Elsevier B.V. AN - OPUS4-45340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Improved algorithm for calibration-free laser induced breakdown spectroscopy N2 - An improved algorithm for calibration-free laser induced breakdown spectroscopy (CF LIBS) is presented which includes several novel features in comparison with previously proposed similar algorithms. In particular, it allows using spectral lines with arbitrary optical thickness for the construction of Saha-Boltzmann plots, retrieves the absorption path length (plasma diameter) directly from a spectrum, replaces the Lorentzian line profile function by the Voigt function, and allows for self-absorption correction using pre-calculated and tabulated data rather than approximating functions. The tabulated data embody the solutions of the radiative transfer equation for numerous combinations of optical thicknesses and line widths. The algorithm is thoroughly verified with synthetic spectra. T2 - 14TH European Workshop on Laser Ablation 2018 (EWLA2018) CY - Pau, France DA - June 26 - 29, 2018 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics KW - Calibration free LIBS PY - 2018 AN - OPUS4-45343 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Laser induced plasma: Modeling, diagnostics, and applications N2 - Laser-induced plasmas are widely used in many areas of science and technology; examples include spectrochemical analysis, thin film deposition, material processing, and even jet propulsion. Several topics will be addressed. First, general phenomenology of laser-induced plasmas will be discussed. Then, a chemical model will be presented based on a coupled solution of Navier-Stokes, state, radiative transfer, material transport, and chemical (Guldberg-Waage) equations. Results of computer simulations for several chemical systems will be shown and compared to experimental observations obtained by optical imaging, spectroscopy, and tomography. The latter diagnostic tools will also be briefly discussed. Finally, a prospective application of laser-induced plasma and plasma modeling will be illustrated on the example of calibration-free MC LIBS (Monte Carlo Laser Induced Breakdown Spectroscopy), in which concentrations of elements in materials are found by fitting model-generated and experimental spectra. T2 - Invited talk at Yeshiva University, New York, USA CY - Yeshiva University, New York, USA DA - 4.24.2018 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics PY - 2018 AN - OPUS4-45344 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Determination of plant essential nutrients in soils using DP-LIBS N2 - In respect of an efficient cultivation of agricultural cropland, a site-specific fertility management is necessary. Therefore, affordable and extensive mapping methods are needed. The research projects I4S (intelligence for soil) has the goal to develop a system for this purpose. I4S is one of ten interdisciplinary research project associations of the innovation programme called BonaRes, which is funded by the German Federal Ministry of Education and Research (BMBF). The system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of major and minor nutrients in soils, like calcium, magnesium, potassium. LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser (1064 nm)was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated. When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, chemometric methods were used. With the principal component analysis (PCA) a classification of soils into different soil types was performed and a calibration curve based on partial least squares regression (PLSR) was generated. With this calibration model’s elemental distribution maps for different German agricultural fields were created. T2 - ESAS CANSAS CY - Berlin, Germany DA - 20.03.2018 KW - LIBS KW - Soil KW - PCA KW - PLSR PY - 2018 AN - OPUS4-45008 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Determination of plant essential nutrients in soils using DP-LIBS N2 - In respect of an efficient cultivation of agricultural cropland, a site-specific fertility management is necessary. Therefore, affordable and extensive mapping methods are needed. For this purpose, the research project I4S (intelligence for soil) has the goal to develop an integrated system. This system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. The main task of LIBS measurements in this project is the real time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser (1064 nm) was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated.[1] When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, chemometric methods were used. With the principal component analysis (PCA) a classification of soils into different soil types was performed and a calibration curve based on partial least squares regression (PLSR) was generated. With this calibration model’s elemental distribution maps for different German agricultural fields were created. T2 - Bonares Conference CY - Berlin, Germany DA - 26.02.2018 KW - LIBS KW - Soil KW - PCA KW - PLSR PY - 2018 AN - OPUS4-45011 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Bestimmung von Makro- und Mikronährstoffen in Böden mittels laserinduzierter Plasmaspektroskopie N2 - In respect of an efficient cultivation of agricultural cropland, a site-specific fertility management is necessary. Therefore, affordable and extensive mapping methods are needed. The research projects I4S (intelligence for soil) has the goal to develop a system for this purpose. I4S is one of ten interdisciplinary research project associations of the innovation programme called BonaRes, which is funded by the German Federal Ministry of Education and Research (BMBF). The system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of major and minor nutrients in soils, like calcium, magnesium, potassium. LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. The main task of LIBS measurements in this project is the real-time determination of the elemental contents of nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate which circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better reproducibility of the obtained signal, a double-pulse Nd:YAG laser (1064 nm) was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated. When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, chemometric methods were used. With the principal component analysis (PCA) a classification of soils into different soil types was performed and a calibration curve based on partial least squares regression (PLSR) was generated. With this calibration model’s elemental distribution maps for different German agricultural fields were created. T2 - Doktorandenseminar AK Prozessanalytik GDCh CY - Berlin, Germany DA - 25.02.2018 KW - LIBS KW - Boden KW - Nährstoffe KW - Univariat KW - Multivariat PY - 2018 AN - OPUS4-45012 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gottlieb, Cassian A1 - Günther, Tobias A1 - Wilsch, Gerd T1 - Impact of grain sizes on the quantitative concrete analysis using laser-induced breakdown spectroscopy N2 - In civil engineering concrete is the most used building material for making infrastructures like bridges and parking decks worldwide. It is as a porous and multiphase material made of aggregates with a defined grain size distribution, cement and water as well as different additives and admixtures depending on the application. Different grain sizes are important to ensure the needed density and compressive strength. The resulting porous cement matrix contains a mixture of flour grains (aggregates with a grain size below 125 lm) and cement particles (particle size≈50lm). Harmful species like chlorides may penetrate together with water through the capillary pore space and may trigger different damage processes. The damage assessment of concrete structures in Germany is estimated due to the quantification of harmful elements regarding to the cement content only. In the evaluation of concrete using LIBS a two-dimensional scanning is necessary to consider the heterogeneity caused by the aggregates. Therefore, a LIBS system operating with a low energy NdCr:YAG laser, a pulse energy of 3 mJ, a wavelength of 1064 nm, a pulse width of 1.5 ns and a Repetition rate of 100 Hz has been used. Different Czerny-Turner spectrometers with CCD detectors in the UV and NIR range have been used for the detection. Large aggregates (macro-heterogeneity) can be excluded from the evaluation, whereas small aggregates in the range of the laser spot size (flour grains) cannot be spatially resolved. In this work the micro heterogeneity caused by flour grains and their impact on the quantification with LIBS will be discussed. To analyze the effect of changing grain sizes and ratios, the ablation behavior has been determined and compared. Samples with defined grain sizes were made and analyzed using LIBS. The grain size distributions were analyzed with laser diffraction (LDA). KW - LIBS KW - Concrete KW - Micro heterogeneity KW - Grain sizes PY - 2018 DO - https://doi.org/10.1016/j.sab.2018.02.004 SN - 0584-8547 SN - 0038-6987 VL - 142 SP - 74 EP - 84 PB - Elsevier AN - OPUS4-44595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Dynamical chemical model of laser induced plasma N2 - Laser induced plasma (LIP) is a highly dynamic, short living event which presents significant difficulty for both diagnostics and modeling. The former requires precise spatially- and time-resolved measurements on a micron-nanosecond scale while the latter needs numerous descriptive parameters; many of them can only be obtained from experiment. Diagnostics and modeling should always complement each other for obtaining a truthful picture of LIP. In this presentation, a newly developed collisional-dominated model will be presented. The model is based on the coupled Navier-Stokes, state, radiative transfer, material transport, and chemical equations. The model incorporates plasma chemistry through the equilibrium approach that relies on atomic and molecular partition functions. Several chemical systems are modeled including Si-C-Cl-N and B-H-Cl systems. The model is used to study the equilibrium states of the systems as functions of the concentrations of plasma species and plasma temperature. The model also predicts the evolution of number densities of atomic and molecular species in the expanding plasma plume. T2 - 18.09.2018, 9th International Conference on PLASMA PHYSICS AND PLASMA TECHNOLOGY (PPPT‐9) CY - Minsk, Belorussia DA - 17.09.2018 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics PY - 2018 AN - OPUS4-46111 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Shabanov, Sergej V. T1 - Chemistry in laser‑induced plasmas at local thermodynamic equilibrium N2 - The equation of state for plasmas containing negative and positive ions of elements and molecules formed by these elements is modeled under the assumption that all ionization processes and chemical reactions are at local thermal equilibrium and the Coulomb interaction in the plasma is described by the Debye–Hückel theory. The hierarchy problem for constants of molecular reactions is resolved by using three different algorithms for high, medium, and low temperatures: the contraction principle, the Newton–Raphson method, and a scaled Newton–Raphson method, respectively. These algorithms are shown to have overlapping temperature ranges in which they are stable. The latter allows one to use the developed method for calculating the equation of state in combination with numerical solvers of Navier–Stokes equations to simulate laser-induced Plasmas initiated in an atmosphere and to study formation of molecules and their ions in such plasmas. The method is applicable to a general chemical network. It is illustrated with examples of Ca–Cl and C–Si–N laser-induced plasmas. KW - Plasma KW - LIBS KW - Plasma modeling PY - 2018 DO - https://doi.org/10.1007/s00339-018-2129-9 SN - 1432-0630 SN - 0947-8396 VL - 124 IS - 10 SP - 716, 1 EP - 21 PB - Springer AN - OPUS4-46112 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Millar, Steven A1 - Gottlieb, Cassian A1 - Sankat, Nina A1 - Wilsch, Gerd A1 - Kruschwitz, Sabine T1 - Chlorine determination in cement-bound materials with Laser-induced Breakdown Spectroscopy (LIBS) – A review and validation N2 - The determination of chloride is still one of the main tasks for the evaluation of reinforced concrete structures. The corrosion of the reinforcement induced by the penetrating chlorides is the dominant damage process affecting the lifetime of concrete structures. In the recent years different research groups demonstrated that LIBS can be a fast and reliable method to quantify chlorine in cement-bound materials. Because chlorine in concrete can only occur as solved ions in the pore solution or bound in salts or hydrated cement phases, the detected emission of chlorine can be correlated with the chloride concentration determined e.g. with potentiometric titration. This work inter alia describes the production of reference samples and possible side effects during the production process. Due to transport processes in the porous matrix of the cement a misinterpretation of the concentrations is possible. It is shown how to overcome these effects and higher precisions of the single measurements can be realised. Using the calibration method, blank sample method and noise method, three different ways of calculating the limit of detection (LOD) and limit of quantification (LOQ) are compared. Due to the preparation of the reference samples a precision of the whole calibration model of sx0 = 0.023 wt% is determined. The validation of the model is based on different test sets, which are varying in their composition (different Cl-salts, water-to-cement ratios and additives). The determined mean error of the validation is 0.595 ± 0.063 wt%, which is comparable to standardised methods like potentiometric titration, direct potentiometry or photometry (0.40 ± 0.06 wt%) [1]. KW - LIBS KW - Chlorine KW - Cement KW - Calibration KW - Validation PY - 2018 DO - https://doi.org/10.1016/j.sab.2018.05.015 SN - 0584-8547 VL - 147 IS - September SP - 1 EP - 8 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-46558 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Völker, Tobias A1 - Mensing, Friedrich A1 - Kruschwitz, Sabine T1 - Estimation of cement content in concrete by spatially resolved laser induced breakdown spectroscopy N2 - The cement content in concrete significantly influences critical properties such as durability, permeability, strength, and workability. Traditional methods for estimating the cement content face limitations. These include the need for comprehensive chemical and solubility knowledge, extensive sample preparation, and their time-consuming and destructive nature. This study investigates the application of laser-induced breakdown spectroscopy (LIBS) as an alternative method. It involves probing concrete samples with high spatial resolution and analyzing the resultant spectra. The methodology is first tested on mesoscale concrete models to assess limitations and inherent errors. Subsequently, the methodology is applied to actual concrete samples with varying cement content and aggregate size distributions. The results demonstrate a promising accuracy, with an average relative error of approximately 8%. This paper offers a comprehensive evaluation of the method's advantages, limitations, and factors influencing its practical applicability in field conditions. KW - LIBS KW - Spectroscopy KW - Cement content KW - Elemental mapping PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-620112 DO - https://doi.org/10.1016/j.cemconres.2024.107714 SN - 1873-3948 VL - 189 SP - 1 EP - 10 PB - Elsevier Ltd. AN - OPUS4-62011 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Völker, Tobias A1 - Mensing, Friedrich A1 - Kruschwitz, Sabine T1 - Estimation of cement content in concrete by spatially resolved laser induced breakdown spectroscopy – Dataset N2 - This dataset includes both simulated and raw measurement data as detailed in the journal paper [1]. File names follow the format SampleNo_Type, where SampleNo corresponds to the sample identifier listed in Table 1, and Type specifies the data type: either syn (synthetic) or exp (experimental). For experimental data, a slice index is appended to the file name in the format SampleNo_Type_Slice, identifying the specific subsample. [1] https://doi.org/10.1016/j.cemconres.2024.107714 KW - LIBS KW - Spectroscopy KW - Cement content KW - Elemental mapping PY - 2024 DO - https://doi.org/10.5281/zenodo.14246581 PB - Zenodo CY - Geneva AN - OPUS4-62394 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völker, Tobias T1 - Laser-Induced Breakdown Spectroscopy for Concrete Analysis: Applications and Practical Benefits N2 - Reinforced concrete structures are exposed not only to mechanical loads but also to chemical degradation, which can significantly impact their longevity and performance. Effective assessment and maintenance require a detailed understanding of the ingress of harmful species, such as chlorides or sulfates. Traditional analysis methods, like wet chemical analysis of drill dust or ground core samples, often require homogenization leading to the loss of crucial spatial information in sub-millimeter regions such as localized high concentrations of elements, e.g. in cracks. Laser-induced breakdown spectroscopy (LIBS) offers a cutting-edge solution, providing rapid, multi-element analysis with high spatial resolution from micrometer to millimeter scales. LIBS is capable of detecting both light and heavy elements, making it a powerful tool for detailed concrete analysis. Despite its clear advantages, LIBS is not commonly used in civil engineering. This presentation will showcase practical examples demonstrating the effectiveness and advantages of LIBS in concrete analysis, highlighting real-world applications provided by members of the “LIBS” subcommittee of the technical committee “Civil-Engineering” of the German Society for Non-Destructive Testing (DGZfP). Key examples will be discussed, including measurements from car parks or bridges, alongside an introduction to the newly released DGZfP leaflet B14 providing guidelines for the quantitative determination of chlorine content in concrete by LIBS. Furthermore, prospective applications of LIBS including material identification and classification for concrete recycling, and other emerging uses in civil engineering, will also be presented, showcasing the versatility and future potential of this technology. T2 - Conference on durability of building materials and systems in the transportation infrastructure CY - Mendrisio, Switzerland DA - 22.03.2025 KW - LIBS KW - Spectroscopy KW - Concrete KW - Structural Diagnostics PY - 2025 AN - OPUS4-62822 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank T1 - Analyse des Tausalzeintrages in Fahrbahndeckenbetone im Kontext der Alkali-Kieselsäure-Reaktion N2 - In den letzten Jahren sind im deutschen Bundesautobahnnetz (BAB-Netz) vermehrt AKR-Schäden an Betonfahrbahndecken aufgetreten, die zum Teil zu einer Halbierung ihrer geplanten Nutzungsdauer von 30 Jahren führte. Ursächlich hierfür ist die Verwendung alkaliempfindlicher Gesteinskörnung, die bei gleichzeitiger Anwesenheit von Wasser infolge der Exposition der Fahrbahndecke und dem alkalischen Milieu durch den Einsatz alkalireicher Portlandzemente bei der Betonherstellung zu einer Alkali-Kieselsäure-Reaktion (AKR) führt. Zusätzlich wird der AKR-Schädigungsprozess in Betonfahrbahndecken durch den externen Tausalzeintrag (primär NaCl) im Winter begünstigt. Vor diesem Hintergrund kommt der Ermittlung des Tausalzeintrags in den Fahrbahndeckenbeton eine große Bedeutung zu. Die Analyse des Tausalzeintrags erfolgte bisher ausschließlich nasschemisch an gemahlenen Bohrkernsegmenten. Nachteilig ist hierbei die fehlende differenzierte Betrachtung des Natriumgehaltes im Zementstein und in der Gesteinskörnung. Der alternative Einsatz von LIBS (Laser-induced breakdown spectroscopy) eröffnet in diesem Kontext neue Möglichkeiten. So wird in diesem Beitrag an Hand von Bohrkernen aus einem AKR-geschädigten BAB-Abschnitt exemplarisch die Vorgehensweise bei der LIBS-Analyse zur Ermittlung der Na- und interagierenden Cl-Verteilung an vertikalen Schnittflächen des Bohrkerns aufgezeigt. Da der Tausalzeintrag primär über den Zementstein erfolgt, wurde der verfälschende Na-Grundgehalt der Gesteinskörnung mittels Zementsteinkriteriums (Nutzung unterschiedlichen Ca-Gehalts in Zementstein und Gesteinskörnung) eliminiert. Vergleichend durchgeführte Cl-Mappings mit Mikroröntgenfluoreszenzanalyse (MRFA) belegen die Güte der durchgeführten LIBS-Messungen. Aber auch bei der Verifizierung der Übertragbarkeit der Ergebnisse der zum Ausschluss reaktiver Gesteinskörnung bei Neubau und Erneuerung im BAB-Netz eingesetzten Performanceprüfungen mit externem Alkalieintrag auf Praxisverhältnisse hat sich das LIBSVerfahren bewährt. So wurde festgestellt, dass die mit NaCl-Lösung beaufschlagten Laborprüfkörper aus einem repräsentativen Fahrbahndeckenbeton bei der Klimawechsellagerung (KWL) über ihre gesamte Höhe von 10 cm einen Eintrag von Na und Cl erfahren. Weiterhin konnte im Gegensatz zu bisherigen Annahmen erstmals mit LIBS und Nasschemie gezeigt werden, dass die Frost-Tauwechsel-Phase bei der KWL zu keinem erhöhten Tausalzeintrag führt. T2 - Fachtagung Bauwerksdiagnose 2018 CY - Berlin, Germany DA - 15.02.2018 KW - Baustoffe KW - Betonfahrbahndecken KW - AKR KW - Tausalzeintrag KW - LIBS KW - MRFA KW - Nasschemie KW - Klimawechsellagerung PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-446499 AN - OPUS4-44649 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank T1 - AKR unter kombinierten Einwirkungen - Rissbildungs- und Transportmechanismen N2 - Die vorstehend dargestellten Untersuchungen lassen sich wie folgt zusammenfassen: • Mit dem für die mechanische Vorschädigung entwickelten Versuchsstand und gewählten Prüfregime können die für die ermüdungsinduzierte Schadensevolution typische stabilisierende und stabile Phase in der auf Zug beanspruchten Betonrandzone gut abgebildet werden. So wurde dort zum Beispiel, ausgehend von dem hier gewählten praxisnahen Belastungsregime, mit Ultraschall in der Ruhephase durch das Trockenschwingen ein maximaler Abfall des relativen dynamischen E-Moduls von ca. 8 - 10 % ermittelt. • Mit aufbauenden kapillaren Aufsaugversuchen wurde gezeigt, dass die erzeugte Betondegradation zu einer moderaten Erhöhung der Aufnahme des Prüfmediums führt. • Zur Bewertung der Auswirkungen einer alleinigen Vorschädigung (Trockenschwingen) auf die schädigende AKR mittels Performance-Prüfung ist die Klimawechsellagerung aufgrund der einseitigen Tausalzbeaufschlagung am besten geeignet. Die hier ermittelten Dehnungsverläufe lassen auf einen moderaten Einfluss der mechanischen Vorschädigung auf die AKR schließen. • Die zusätzlich im Kontext der Nasschwingversuche durchgeführten 60°C Betonversuche zeigen, dass die zyklische Beanspruchung vor und nach dem Aufbringen der Tausalzlösung die schädigende AKR gleichfalls moderat erhöht. In derzeit laufenden ergänzenden Untersuchungen wird der separate Einfluss der ermüdungsinduzierten Rissbildung auf die schädigende AKR an homogen, stärker geschädigten Prüfkörpern mit einem hohen inneren AKR-Schädigungspotenzial im 60°C Betonversuch grundhaft analysiert. Zusätzlich wird gegenwärtig der Einfluss der degradierten Betonrandzone auf die Dehnungsverteilung an großformatigen Prüfkörpern über die Höhe im 40°C Betonversuch vertiefend für die makroskopische Modellierung untersucht. T2 - 20. Internationale Baustofftagung ibausil CY - Weimar, Germany DA - 12.09.2018 KW - Betonfahrbahndecke KW - Alkali-Kieselsäure-Reaktion KW - Tausalz KW - LIBS KW - MRFA KW - Nasschemie KW - ZfP PY - 2018 AN - OPUS4-46189 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank A1 - Krütt, Enno A1 - Meng, Birgit T1 - AKR unter kombinierten Einwirkungen - Rissbildungs- und Transportmechanismen N2 - Die vorstehend dargestellten Untersuchungen lassen sich wie folgt zusammenfassen: • Mit dem für die mechanische Vorschädigung entwickelten Versuchsstand und gewählten Prüfregime können die für die ermüdungsinduzierte Schadensevolution typische stabilisierende und stabile Phase in der auf Zug beanspruchten Betonrandzone gut abgebildet werden. So wurde dort zum Beispiel, ausgehend von dem hier gewählten praxisnahen Belastungsregime, mit Ultraschall in der Ruhephase durch das Trockenschwingen ein maximaler Abfall des relativen dynamischen E-Moduls von ca. 8 - 10 % ermittelt. • Mit aufbauenden kapillaren Aufsaugversuchen wurde gezeigt, dass die erzeugte Betondegradation zu einer moderaten Erhöhung der Aufnahme des Prüfmediums führt. • Zur Bewertung der Auswirkungen einer alleinigen Vorschädigung (Trockenschwingen) auf die schädigende AKR mittels Performance-Prüfung ist die Klimawechsellagerung aufgrund der einseitigen Tausalzbeaufschlagung am besten geeignet. Die hier ermittelten Dehnungsverläufe lassen auf einen moderaten Einfluss der mechanischen Vorschädigung auf die AKR schließen. • Die zusätzlich im Kontext der Nasschwingversuche durchgeführten 60°C Betonversuche zeigen, dass die zyklische Beanspruchung vor und nach dem Aufbringen der Tausalzlösung die schädigende AKR gleichfalls moderat erhöht. In derzeit laufenden ergänzenden Untersuchungen wird der separate Einfluss der ermüdungsinduzierten Rissbildung auf die schädigende AKR an homogen, stärker geschädigten Prüfkörpern mit einem hohen inneren AKR-Schädigungspotenzial im 60°C Betonversuch grundhaft analysiert. Zusätzlich wird gegenwärtig der Einfluss der degradierten Betonrandzone auf die Dehnungsverteilung an großformatigen Prüfkörpern über die Höhe im 40°C Betonversuch vertiefend für die makroskopische Modellierung untersucht. T2 - 20. Internationale Baustofftagung ibausil CY - Weimar, Germany DA - 12.09.2018 KW - Betonfahrbahndecke KW - Alkali-Kieselsäure-Reaktion KW - Tausalz KW - LIBS KW - MRFA KW - Nasschemie KW - ZfP PY - 2018 SN - 978-3-00-059950-7 SP - 1 EP - 13 AN - OPUS4-46174 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gottlieb, Cassian A1 - Millar, Steven A1 - Günther, Tobias A1 - Wilsch, Gerd T1 - Revealing hidden spectral information of chlorine and sulfur in data of a mobile Laser-induced Breakdown Spectroscopy system using chemometrics N2 - For the damage assessment of reinforced concrete structures the quantified ingress profiles of harmful species like chlorides, sulfates and alkali need to be determined. In order to provide on-site analysis of concrete a fast and reliable method is necessary. Low transition probabilities as well as the high ionization energies for chlorine and sulfur in the near-infrared range makes the detection of Cl I and S I in low concentrations a difficult task. For the on-site analysis a mobile LIBS-system (k = 1064 nm, Epulse ≤ 3 mJ, t = 1.5 ns) with an automated scanner has been developed at BAM. Weak chlorine and sulfur signal intensities do not allow classical univariate analysis for process data derived from the mobile system. In order to improve the analytical performance multivariate analysis like PLS-R will be presented in this work. A comparison to standard univariate analysis will be carried out and results covering important parameters like detection and quantification limits (LOD, LOQ) as well as processing variances will be discussed (Allegrini and Olivieri, 2014 [1]; Ostra et al., 2008 [2]). It will be shown that for the first time a low cost mobile system is capable of providing reproducible chlorine and sulfur analysis on concrete by using a low sensitive system in combination with multivariate evaluation. KW - LIBS KW - Chemometrics KW - Building materials PY - 2017 DO - https://doi.org/10.1016/j.sab.2017.04.001 SN - 0584-8547 VL - 132 SP - 43 EP - 49 PB - Elsevier B.V. AN - OPUS4-40066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Aktuelle Herausforderungen für die Prozessanalytik – von der Online-NMR-Spektroskopie im Feld bis zum Plasmaspektrometer auf dem Acker N2 - Der Vortrag stellt einige aktuelle Herausforderungen für die Prozessanalytik und mögliche Antworten vor. Gepulste Raman-Spektrometer akkumulieren das Raman-Signal mit Hilfe schneller optischer Schalter im Picosekunden-Bereich, bevor langlebigere Fluoreszenzanregung entsteht. Damit lassen sich stark fluoreszierende Materialien untersuchen, die bislang nicht zugänglich sind. Eine weitere interessante Entwicklung ist etwa die Shifted excitation Raman difference spectroscopy (SERDS) die besonders für biologische Anwendungen interessant ist. Flexible, modulare Produktionsanlagen stellen einen vielversprechenden Ansatz für die kontinuierliche Produktion von Fein- und Spezialchemikalien dar. In einem EU-Projekt wird derzeit die Feldintegration eines Online-NMR-Sensormoduls als smartes Modul für die Prozesskontrolle vorangebracht. Dieses Modul basiert auf einem kommerziell erhältlichen Niederfeld-NMR-Spektrometer, welche zurzeit für die Anwendung im Laborbereich erhältlich ist. Für die Feldintegration wurde ein ATEX-zertifiziertes, explosionsgeschütztes Gehäuse entwickelt sowie Automationsschemen für den unbeaufsichtigten Betrieb und für die spektrale Datenauswertung erstellt. Eine sehr gut anwendbare analytische Messtechnik zur Kontrolle der elementaren Zusammensetzung von verschiedensten Materialien ist die laserinduzierte Plasmaspektroskopie (LIPS, engl. LIBS - Laser-induced Breakdown Spectroscopy). Bei der LIBS wird ein kurz gepulster Laser auf eine Probe fokussiert, um ein Leuchtplasma zu erzeugen. Das dabei erzeugte Atomemissionsspektrum ermöglicht eine qualitative und quantitative Analyse der Zusammensetzung der Probe bezüglich praktisch aller Elemente des Periodensystems. In einem aktuellen Projekt wird diese Methode neben anderen zur Online-Analyse von Ackerböden für die ortsspezifischer Bewirtschaftung (Precision Agriculture) weiterentwickelt und bewertet. T2 - Vortragsreihe Analytik, Merck KGaA CY - Darmstadt, Germany DA - 19.05.2017 KW - Prozessanalytik KW - Reaction Monitoring KW - Online NMR Spektroskopie KW - LIBS KW - RFA KW - Raman-Spektroskopie KW - BONARES KW - CONSENS PY - 2017 AN - OPUS4-40328 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilsch, Gerd A1 - Eichler, T. A1 - Millar, Steven A1 - Gottlieb, Cassian T1 - Quantitative determination of chloride-to-cement content of concrete by laser-induced breakdown spectroscopy (LIBS) N2 - Laser-induced breakdown spectroscopy (LIBS) is a combination of plasma generation on the sample surface by a high power laser pulse and optical emission spectroscopy (OES). It is a direct measurement method without an extensive sample preparation. Concrete is a multi phase system. With LIBS it is possible to distinguish the different phases and based on that to correlate the chloride content to the cement mass. This is done by scanning the surface with a resolution of up to 0.1 mm. The high measurement frequency of 100 Hz or even higher allows the in-situ visualization of the chloride content over the measured area. With a calibration a quantification of chloride concentration is possible. As an example the LIBS measurement on a 50 mm by 70 mm area with a resolution of 0.5 mm and the visualization of the chloride distribution takes only 10 minutes. Additionally it is possible to evaluate the carbonation depth from the same measurement. Examples of practical application to determine the chloride-to-cement-content on concrete samples are presented. The possibilities and the limitations of LIBS are discussed. T2 - CONCREEP 10 - Mechanics and physics of creep, shrinkage, and durability of concrete and concrete structures CY - Vienna, Austria DA - 21.09.2015 KW - LIBS KW - Chlorides KW - Carbonation KW - Heterogeneity KW - Quantitative concentration KW - 2D-map PY - 2015 SP - 815 EP - 822 AN - OPUS4-34677 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühlmann, Madlen T1 - Design of an online-analysis technique for the determination of major and minor nutrients in soils using DP-LIBS N2 - LIBS (laser-induced breakdown spectroscopy) is known as a fast and simultaneous multi-element analysis with little or no sample preparation. Because of that, over the last few years there has been a growing interest in applications of LIBS in the field of agriculture. As part of the National Research Strategy BioEconomy 2030 the German Federal Ministry of Education and Research (BMBF) started an innovation programme called BonaRes. BonaRes consists of ten interdisciplinary research project as-sociations which are dealing with soil as a sustainable resource for the bio-economy. One of these research projects is I4S (intelligence for soil) which has the goal to develop an integrated system for site-specific soil fertility management. This system includes a sensor platform, which contains different sensors, like XRF, VIS-NIR, Gamma and LIBS. The main task of LIBS measurements in this project is the real time determination of the elemental contents of major and minor nutrients in soils, like calcium, magnesium, potassium. For this purpose, a special setup has been designed. The sample uptake operates with the help of a rotatable sample plate, on which the loose soil sample can be placed in form of a track. The sample plate circulates with different velocities to simulate the application on the field. To provide a higher intensity and a better re-producibility of the obtained signal, a double-pulse Nd:YAG laser (1064 nm) was used. In order to minimize dust formation from the soil during the operation of the laser, a dust removal by suction has been integrated When using relative methods such as LIBS, a suitable calibration curve is needed for absolute quantification. Within the I4S project a large number of soil samples from different testing grounds with known data of chemical composition, texture etc. is available. For the first calibration curves seven soil samples from different grounds in Germany were prepared as reference materials and four certified reference materials from China and Canada were purchased. With the help of these reference materials, calibration curves for different elements were initially calculated based on internal standard addi-tion. Copper was used as internal standard because of its low concentration in soils. The complex matrix of soils, as well as the influence of moisture and grain size in soils makes the absolute quantification by LIBS challenging. To overcome these influences, a calibration curve based on multivariate analysis was generated. Therefore, baseline correction on the second derivative with a Savitzky-Golay filter was followed by a partial least squares regression (PLSR). Multivariate analysis leads to noise reduction and neglection of interfering signals. Therefore, a better correlation between signal intensity and nutrient concentration is observed and a robust calibration curve is obtained. T2 - 9. Euro-Mediterranes Symposium LIBS CY - Pisa, Italy DA - 11.06.2017 KW - LIBS KW - Soil KW - Matrix KW - Multi-element PY - 2017 AN - OPUS4-40807 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gebbers, R. T1 - Laser-induced breakdown spectroscopy (LIBS) for efficient quantitative determination of elemental plant nutrients in soils: A contribution to precision agriculture N2 - One important aim of precision agriculture (PA) is the optimization of crop growth by means of site-specific measures, e.g. fertilizer application. Thus, PA should contribute to a resource efficient and ecofriendly soil management. Due to the expenses associated with traditional methods of soil analysis, requiring sample collection and laboratory analysis, PA technologies are still not in widespread use. Therefore, the aim of the project “I4S – Integrated System for Site-Specific Soil Fertility Management” is the development of a field-deployed, sensor-based analysis system offering rapid, cost-effective and spatially-resolved fertilizer recommendations. In this system, laser-induced breakdown spectroscopy (LIBS) could be ideally suited to assessing elemental nutrient contents of soils. In addition to low cost, durability and small size, a reliable quantification procedure is a crucial requirement for such a system. However, the texture as well as the composition of the soil can affect the spectra. This matrix dependence is the key challenge to be addressed in the application of LIBS for soil evaluation. The focus of this work was the establishment of a LIBS method for soil analysis in a laboratory environment for future field application. Natural soil samples of various origins, textures and compositions were used to characterize the matrix dependence of the LIBS spectra. Reference samples were prepared by adding defined amounts of the target elements to the soils (standard addition). Signals not superimposed by peaks of other elements were identified for each element. The reference samples also provided calibration curves for the respective soil type when the initial concentrations in the soils were taken into account. Additionally, the common laboratory method ICP-OES following aqua regia extraction was used to obtain reference values. Various approaches of calibration free evaluation of the data were also evaluated. In addition to traditional single-pulse experiments, the advantages of dual-pulse LIBS in relation to signal intensity, reproducibility as well as overcoming the matrix dependence of soil spectra were investigated. These methods were subsequently applied to validation samples collected on a dense grid within a field. T2 - Pedometrics 2017 CY - Wageningen, The Netherlands DA - 26.06.2017 KW - LIBS KW - Precision KW - Agriculture KW - Soil KW - Site-specific PY - 2017 AN - OPUS4-40808 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gottlieb, Cassian A1 - Millar, Steven A1 - Grothe, S. A1 - Wilsch, Gerd T1 - 2D evaluation of spectral LIBS data derived from heterogeneous materials using cluster algorithm N2 - Laser-induced Breakdown Spectroscopy (LIBS) is capable of providing spatially resolved element maps in regard to the chemical composition of the sample. The evaluation of heterogeneous materials is often a challenging task, especially in the case of phase boundaries. In order to determine information about a certain phase of a material, the need for a method that offers an objective evaluation is necessary. This paper will introduce a cluster algorithm in the case of heterogeneous building materials (concrete) to separate the spectral information of non-relevant aggregates and cement matrix. In civil engineering, the information about the quantitative ingress of harmful species like Cl−, Na+ and SO2−4 is of great interest in the evaluation of the remaining lifetime of structures (Millar et al., 2015; Wilsch et al., 2005). These species trigger different damage processes such as the alkali-silica reaction (ASR) or the chloride-induced corrosion of the reinforcement. Therefore, a discrimination between the different phases, mainly cement matrix and aggregates, is highly important (Weritz et al., 2006). For the 2D evaluation, the expectation-maximizationalgorithm (EM algorithm; Ester and Sander, 2000) has been tested for the application presented in this work. The method has been introduced and different figures of merit have been presented according to recommendations given in Haddad et al. (2014). Advantages of this method will be highlighted. After phase separation, non-relevant information can be excluded and only the wanted phase displayed. Using a set of samples with known and unknown composition, the EM-clustering method has been validated regarding to Gustavo González and Ángeles Herrador (2007). KW - LIBS KW - Concrete KW - EM-clustering KW - Heterogeneity PY - 2017 DO - https://doi.org/10.1016/j.sab.2017.06.005 SN - 0584-8547 VL - 2017 IS - 134 SP - 58 EP - 68 PB - Elsevier B.V. AN - OPUS4-40644 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Kazakov, Alexander Ya. T1 - Kinetic model of stimulated emission created by resonance pumping of aluminum laser-induced plasma N2 - Stimulated emission observed experimentally in an aluminum laser induced plasma is modeled via a kinetic approach. The simulated emission at several cascade transitions is created by a pump laser guided through the plasma at several microseconds after its creation and tuned in resonance with the strong 3s²3p-3s²4s transition at 266 nm. A two-dimensional space-time collisional radiative plasma model explains the creation of the Population inversion and lasing at wavelengths of 2100 nm and 396.1 nm. The population inversion for lasing at 2100 nm is created by depopulation of the ground 3s²3p state and population of the 3s²5s state via the absorption of the resonant radiation at 266 nm. The population inversion for lasing at 396.1 nm occurs during the laser pulse via the decay of the population of the pumped 3s²5s state to the excited 3s²4s state via cascade transitions driven optically and by collisions. In particular, efficient are the mixing transitions between neighboring states separated by small gaps on the order of kT at Plasma temperatures of 5000–10 000 K. The model predicts that the population inversion and corresponding gain may reach high values even at very moderate pump energy of several lJ per pulse. The efficiency of lasing at 2100 nm and 396.1 nm is estimated to be ~3% and 0.05%, correspondingly with respect to the pump laser intensity. The gain for lasing at 396.1 nm can reach as high as ~40 cm⁻¹. The polarization effect that the pump radiation at 266 nm imposes on the stimulated emission at 396.1 nm is discussed. The calculated results are favorably compared to experimental data. KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics KW - Lasers PY - 2017 DO - https://doi.org/10.1063/1.4984912 SN - 0021-8979 SN - 1089-7550 VL - 121 IS - 21 SP - 213303-1 EP - 213303-11 AN - OPUS4-40693 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, Cassian T1 - Material properties and their impact on laserinduced plasmas for concrete analysis N2 - For concrete production aggregates, cement and water are mixed together and after 28 days of hydration a porous and multiphase material is formed. To consider the heterogeneity of concrete a 2D scanning system is used. The coarse aggregates (limit > 2 X d ) can be excluded. laser spot The remaining content is a mixture of flour grains and cement particles (micro heterogeneity). Harmful species like chlorides may penetrate together with water through the capillary pore space. A quantification of Cl regarding to the cement content only (European standard EN 206) is necessary for the damage assessment. A LIBS system operating with a NdCr:YAG laser (pulse energy of 3 mJ, a wavelength of 1064 nm, a pulse width of 1.5 ns, a repetition rate of 100 Hz) and two Czerny-Turner spectrometer (UV and NIR range) have been used. T2 - EMSLIBS Konferenz 2017 CY - Pisa, Italy DA - 12.06.2017 KW - Concrete KW - LIBS KW - Micro-heterogeneity PY - 2017 AN - OPUS4-40938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottlieb, Cassian T1 - Influence of grain sizes on the quantification of libs measurements in concrete influence of grain sizes on the quantification of libs measurements in concrete N2 - Concrete is a multiphase material made of cement, aggregates and water. The heterogeneity of concrete is a result of mixing aggregates (grain size between 0.125 mm to 32 mm) and cement (grain size < 0.04 mm) together. There are always aggregates with a grain size below 0.125 mm (flour grains) therefore the cement matrix is always a mixture of these small particles. Different grain size distributions by making concrete are important to ensure the needed density and com-pressive strength. In order to estimate the remaining lifetime of concrete structures the quantification of element concentra-tions of alkali and chlorides regarding to the cement matrix only (1/3 of the total mass), is a major concern in civil engineer-ing. Due to two-dimensional scanning with LIBS the coarse aggregates can be evaluated and excluded from the analysis. In the case of particles (flour grains and cement) smaller than the laser spot size, the microscopic hetero-geneity influences the laser-plasma interaction and has therefore an impact on the results. In this study the influence of the micro-heterogeneity and the impact on the laser-material interaction is examined. The effect of changing ratios between cement particles and aggregate particles in the laser-induced plasma has been analyzed (see figure 1, right). Therefore, different samples with defined grain sizes are prepared and the obtained distributions were analyzed with x-ray diffraction (XRD). For the LIBS measurements, an automated system that operates with a low energy NdCr:YAG laser (pulse energy of 3 mJ, a wavelength of 1064 nm, a pulse width of 1.5 ns, a repetition rate of 100 Hz) and a NIR Czerny-Turner spectrometer has been used. T2 - EMSLIBS Konferenz 2017 CY - Pisa, Italy DA - 12.06.2017 KW - Grain size KW - LIBS KW - Concrete PY - 2017 AN - OPUS4-40940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wiggenhauser, Herbert A1 - Kind, Thomas A1 - Mielentz, Frank A1 - Strangfeld, Christoph A1 - Völker, Christoph A1 - Wilsch, Gerd T1 - Non-destructive testing in civil engineering at BAM N2 - Research and Development in Non-Destructive Testing in Civil Engineering at BAM has de-veloped over more than two decades. Highlights of present research are ultrasound phase array probes, ground penetrating radar applications for the assessment of existing structures and Laser Induced Breakdown Spec-troscopy (LIBS) to determine which chemical elements on the surface of a specimen are. RFID sensor devel-opments for wireless moisture monitoring and data fusion for the combined analysis of sensor data are fast developing areas. In addition, a selection of application cases is briefly described. T2 - Vortrag über die Aktivitäten des Fachbereichs 8.2 in der zerstörungsfreien Prüfung im Bauwesen. KW - Ultrasonic testing KW - RFID-sensors KW - Data fusion KW - Ground penetrating radar KW - LIBS PY - 2017 SP - 1 EP - 10 CY - Berlin AN - OPUS4-44132 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weise, Frank A1 - Millar, Steven A1 - Wilsch, Gerd T1 - Analyse des Tausalzeintrags in Fahrbahndeckenbetone mit neuartiger Prüftechnik T1 - Analysis of De-icing Salt in Concrete Pavement with a new type of Test Technology N2 - In den letzten Jahren sind im deutschen Bundesautobahnnetz vermehrt AKR-Schäden an Betonfahrbahndecken aufgetreten. Ursächlich hierfür ist die Verwendung alkaliempfindlicher Gesteinskörnung. Dies führt bei gleichzeitiger Anwesenheit von Wasser infolge der Exposition der Fahrbahndecke und des alkalischen Milieus durch den Einsatz alkalireicher Portlandzemente bei der Betonherstellung zu einer Alkali-Kieselsäure-Reaktion (AKR). Zusätzlich wird der AKR-Schädigungsprozess in Betonfahrbahndecken durch den externen Tausalzeintrag (primär NaCl) im Winter begünstigt. Vor diesem Hintergrund kommt der Ermittlung des Tausalzeintrags in den Fahrbahndeckenbeton eine große Bedeutung zu. Die Analyse des Tausalzeintrags erfolgte bisher ausschließlich nasschemisch an gemahlenen Bohrkernsegmenten. Nachteilig sind hierbei der relativ hohe prüftechnische Aufwand und die eingeschränkte Ortsauflösung. Der alternative Einsatz von LIBS (Laser-induced breakdown spectroscopy) eröffnet in diesem Kontext neue Möglichkeiten. So wird in diesem Beitrag anhand von Bohrkernen aus einem repräsentativen AKR-geschädigten BAB-Abschnitt exemplarisch die Vorgehensweise bei der LIBS-Analyse zur Ermittlung der Na- und Cl-Verteilung an vertikalen Schnittflächen von Bohrkernen aufgezeigt. Da der Tausalzeintrag primär über den Zementstein erfolgt, wurde der verfälschende Na-Grundgehalt der Gesteinskörnung mittels eines Ausschlusskriteriums (Ca-Gehalt) eliminiert. Vergleichend durchgeführte Cl-Mappings mit Mikroröntgenfluoreszenzanalyse sowie nasschemische Analysen belegen die Güte der durchgeführten LIBS-Messungen. Allerdings bedarf es bei der quantitativen Ermittlung des Natriumgehaltes in der Betonfahrbahndecke noch weitergehender Untersuchungen. N2 - Analysis of the intrusion of de-icing salt into concrete pavements by a novel test method In recent years the German motorway network has seen an increase in the occurrence of damage in concrete pavements. This has been caused by the use of alkali-sensitive aggregates. Given the exposure of the concrete pavement to water and the alkaline environment caused by the use of Portland cement during concrete mixing, this environment can lead to an alkali-silica reaction (ASR) process. This ASR-damage process in concrete pavements is further exacerbated by the external application of de-icing salt in winter. Against this background, the evaluation of the intrusion of de-icing salt becomes of great importance. Until now, the analysis of the intrusion of de-icing salt was carried out in a wet-chemistry process on finely ground segments of drilling cores. The disadvantages of this method are the relatively arduous testing process and the limited depth resolution. The alternative application of LIBS (laser-induced breakdown spectroscopy) offers new possibilities in this context. In this paper, the procedure for the LIBS analysis of sodium and chloride distribution on vertical cut surfaces of drilling cores taken from representative ASR-damaged concrete pavements is presented. Because the intrusion of de-icing salt takes place primarily in the cement matrix, the distorting effect of the sodium content in the aggregates was eliminated by an exclusion criteria (namely, the calcium content). The comparable chloride mappings by micro X-ray fluorescence spectroscopy and wet-chemical analysis confirm the quality of the LIBS measurements. However, additional investigations are necessary for the quantitative analysis of sodium content in concrete pavements. KW - Betonfahrbahndecke KW - Alkali-Kieselsäure-Reaktion KW - Tausalz KW - LIBS KW - MRFA KW - Nasschemie KW - ZfP PY - 2018 DO - https://doi.org/10.1002/best.201800033 SN - 0005-9900 SN - 1437-1006 VL - 113 IS - 9 SP - 656 EP - 666 PB - Wilhelm Ernst & Sohn, Verlag für Architektur und technische Wissenschaften GmbH & Co. KG CY - Berlin AN - OPUS4-46171 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Völker, Tobias A1 - Millar, Steven A1 - Strangfeld, Christoph A1 - Wilsch, Gerd T1 - Identification of type of cement through laser-induced breakdown spectroscopy N2 - The composition of concrete determines its resistance to various degradation mechanisms such as ingress of ions, carbonation or reinforcement corrosion. Knowledge of the composition of the hardened concrete is therefore helpful to assess the remaining service life of an existing structure or evaluate the damage observed during inspections. For example, for most existing concrete structures the type of cement originally used is not known and must therefore be determined afterwards. This paper presents a preliminary study on the application of laser-induced breakdown spectroscopy (LIBS) to identify the type of cement. For this purpose, ten different types of cement were investigated. For every type, three cement paste prisms were produced: (i) prisms dried, ground and pressed into tablets, (ii) prisms dried and (iii) prisms untreated. LIBS measurements were performed with a diode-pumped low energy laser (1064 nm, 3 mJ, 1.5 ns, 100 Hz) in combination with two compact spectrometers which cover the UV and NIR spectral range. A reduced subset of spectral features was used to build a classification model based on linear discriminant analysis. The results show that the classification of homogenized pressed cement powder samples provides a high accuracy, however, factors such as a different sample matrix and moisture content can affect the accuracy of the classification. The study demonstrates that LIBS is a promising tool to identify the type of cement. KW - Spectroscopy KW - LIBS KW - Cement KW - Classification KW - Identification PY - 2020 DO - https://doi.org/10.1016/j.conbuildmat.2020.120345 VL - 258 SP - 120345 PB - Elsevier Ltd. AN - OPUS4-51157 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Völker, Tobias A1 - Gornushkin, Igor B. T1 - Mass and mole fractions in calibration-free LIBS N2 - This technical note highlights the fact that CF-LIBS algorithms work in mole fractions, while results of spectrochemical analysis are usually reported in mass fractions or mass percent. Ignoring this difference and not converting mole fractions to mass fractions can lead to errors in reported concentrations determined by the CF-LIBS method and inadequate comparison of these concentrations with certified concentrations. Here, the key points of the CF-LIBS algorithm are reproduced and the formulae for converting a mole fraction to a mass fraction and vice versa are given. Several numerical examples are also given, which show that the greater the difference between the molar mass of an individual element in a sample and the average molar mass, the greater the discrepancy between the mole and mass fractions. KW - Spectroscopy KW - Analytical Chemistry KW - LIBS KW - Calibration PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-598611 DO - https://doi.org/10.1039/d4ja00028e SN - 0267-9477 VL - 39 IS - 4 SP - 1030 EP - 1032 PB - Royal Society of Chemistry (RSC) AN - OPUS4-59861 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Chemometric tools for LIBS analysis N2 - LIBS matures to a quantitative method for elemental analysis rather than a qualitative diagnostic tool. Numerous real world applications for bulk and microanalysis profit from instrumental and methodical advances in the last decade. Today, recording of numerous spectra from samples can be done with low experimental efforts and low cost per spectrum. Not surprisingly, LIBS data, with a high spectral resolution and a broad spectral range, become “big data” and can be utilized in different ways beyond elemental analysis. But, what is the generic or best approach for quantitative LIBS analysis? What techniques can be employed to gain new insights into data? Emergent information can arise through data fusion of LIBS data with other data, i.e. orthogonal spectroscopic or other information related to the sample. But are fused data better than data from a single method? This talk will provide an in-depth overview what chemometric tools can do for LIBS. For quantitative analysis, pre-processing tools are essential to improve precision, accuracy, and reproducibility but at the same time their application to data is still based on phenomenological criteria. Multivariate analysis seems to dominate LIBS, but are there drawbacks on using all information from spectra. For different data sets from real applications, the use of multivariate calibration and (un)supervised pattern recognition will be discussed in comparison with reference analytical methods and possible improvements through plasma diagnostics and modelling. T2 - 9th International Confrence on Laser-Indusced Breakdown Spectroscopy (LIBS) CY - Charmonix-Mont-Blanc, France DA - 12.09.2016 KW - Chemometrics KW - Analytical method KW - LIBS PY - 2016 AN - OPUS4-37534 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Diagnostics and modeling of laser induced plasma in relation to current needs of spectrochemical analysis N2 - The short report on computer modeling and diagnostics of laser induced plasmas T2 - Winter Plasma Conference CY - Tucson, USA DA - 08.01.2016 KW - Plasma diagnostics KW - Laser induced plasma KW - LIBS KW - Plasma modeling PY - 2016 AN - OPUS4-38773 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Quackatz, Lukas A1 - Gornushkin, Igor B. A1 - Griesche, Axel A1 - Kannengießer, Thomas A1 - Treutler, Kai A1 - Wesling, Volker T1 - In situ chemical analysis of duplex stainless steel weld by laser induced breakdown spectroscopy N2 - The high corrosion resistance and good mechanical properties of duplex stainless steel (DSS) are due to its special chemical composition, which is a balanced phase ratio of ferrite (α) and austenite (γ). Many industrial applications require the integration of DSS components. For this, Gas tungsten arc welding (GTAW) is an excellent choice, as it allows an automated operation with high reproducibility. However, when the weld pool solidifies, critical ratios of α- and γ- phases can occur, which lead to solidification cracking, increased susceptibility to corrosion, and a decrease in ductility and critical strength. Previous studies have shown that these defects can be caused by the accumulation of manganese and chromium in the heat affected zone (HAZ), requiring ongoing monitoring of this accumulation. A suitable method for such monitoring is laser-induced breakdown spectroscopy (LIBS), which can be used in two operating modes: calibration using standard reference samples and calibration-free. Unlike conventional quantitative LIBS measurements, which require reference samples to generate a calibration curve, calibration-free LIBS (CF-LIBS) allows chemical compositions to be determined solely from the emission spectrum of the plasma. Numerous publications show that CF-LIBS is a fast and efficient analytical method for the quantitative analysis of metal samples. In this work, CF-LIBS is applied to spectra obtained during GTAW DSS welding and the result is compared with those obtained by PLS analysis. A good correlation was found between both types of analysis, demonstrating the suitability of the CF-LIBS method for this application. The CF-LIBS method has a significant advantage over conventional LIBS due to the rapid in situ measurement of concentrations of major alloying elements without calibration procedure. This, combined with fast feedback and appropriate adjustment of welding parameters, helps prevent welding defects. KW - Duplex stainless steels KW - In situ measurement KW - LIBS KW - GMAW PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597940 DO - https://doi.org/10.1016/j.sab.2024.106899 SN - 0584-8547 VL - 214 SP - 1 EP - 7 PB - Elsevier B.V. AN - OPUS4-59794 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Calibration-free Monte Carlo method for laser induced breakdown spectroscopy N2 - Calibration-free LIBS via Monte Carlo approach T2 - 8-14.10.2017 SciX, Reno, NV, USA CY - Reno, NV, USA DA - 7.10.2016 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics KW - Lasers PY - 2017 AN - OPUS4-42298 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Calibration-free Monte Carlo method for laser induced breakdown spectroscopy N2 - Calibration-free LIBS by Monte Carlo simulation of plasma spectra T2 - April 26 2017, Johannes Kepler University, Linz, Austria CY - Johannes Kepler University, Linz, Austria DA - 26.04.2017 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics PY - 2017 AN - OPUS4-42288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Model of stimulated emission in aluminium laser-induced plasma produced by resonance pumping N2 - Model of lasing effect in resonantly pumped aluminum laser induced plasma T2 - EMS LIBS CY - Pisa, Italy DA - 11.06.2017 KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Plasma diagnostics PY - 2017 AN - OPUS4-42292 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Taparli, Ugur Alp T1 - In situ laser-induced breakdown spectroscopy measurements in stainless steels during TIG welding N2 - Chemical composition of the welding seam and HAZ has significant effect on weld quality. Current inspection methods for weld seams measure and investigate post factum and cannot prevent weld defects. Element burn-off may significantly affect solidification leading to embrittlement or cracking Control of weld chemical compositions insures a controlled solidification and resistance to related weld defects. A prototype of a LIBS controlled welding process is presented. T2 - Forschungsseminar Universität Magdeburg CY - Magdeburg, Germany DA - 17.01.2018 KW - LIBS KW - TIG-Welding KW - Chemical compositions KW - In situ measurements PY - 2018 AN - OPUS4-43830 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Taparli, Ugur Alp T1 - Development of a LIBS analysis system for time- and spaceresolved in situ measurement of chemical compositions during GTA-Welding N2 - A laser induced breakdown spectroscopy (LIBS) system was combined with the Gas Tungsten Arc (GTA) Welding process for the in situ measurement of chemical compositions in austenitic stainless steels during welding. The purpose of this project is to develop a prototype of an online chemical composition control system for welding applications. One of the use cases of this new LIBS-based measurement system can be the controlling of potentially dangerous emissions during the welding process in order to improve the working safety conditions. Further, the control of the weld pool composition allows governing the weld pool solidification behavior and thus allows reducing the resultant susceptibility for solidification cracking. The composition of the weld seam is from the metallurgical point of view the most critical parameter for the occurrence of weld defects1. Conventional inspection methods for weld seams as e.g. ultrasonic inspection are ex situ and cannot prevent the defects. For that reason automated in situ analysis systems for weld defect detection are much more efficient2. Beyond that, the proposed LIBS-based analysis system allows to study the correlation between the occurrence of weld defects and the chemical composition of the weld pool or the region where solid and liquid phase coexist. T2 - The 9th International Conference on Laser-Induced Breakdown Spectroscopy (LIBS 2016) CY - Charmonix, France DA - 12.09.2016 KW - In situ measurement KW - GTA-Welding KW - LIBS PY - 2016 AN - OPUS4-37417 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Chao, Madlen T1 - Entwicklung und Validierung eines Online-LIBS-Verfahrens für die Bestimmung von Nährelementen in Böden N2 - In den letzten Jahrzehnten ist die Nachfrage nach kostengünstigen und flächendeckenden Kartierungsmöglichkeiten im Hinblick auf eine ertragssteigernde und umweltfreundlichere Bewirtschaftung von landwirtschaftlichen Nutzflächen stark gestiegen. Hierfür eignen sich spektroskopische Methoden wie die Röntgenfluoreszenzanalyse (RFA), Raman- und Gammaspektroskopie sowie die laserinduzierte Plasmaspektroskopie (LIBS). In Abhängigkeit von der Funktionsweise der jeweiligen Methoden werden Informationen zu verschiedensten Bodeneigenschaften wie Nährelementgehalt, Textur und pH-Wert erhalten. Ziel dieser Arbeit ist die Entwicklung eines Online-LIBS-Verfahrens zur Nährelementbestimmmung und Kartierung von Ackerflächen. Die LIBS ist eine schnelle und simultane Multielementanalyse bei der durch das Fokussieren eines hochenergetischen Laserpulses Probenmaterial von der Probenoberfläche ablatiert wird und in ein Plasma überführt wird. Beim Abkühlen des Plasmas wird Strahlung emittiert, welche Rückschlüsse über die elementare Zusammensetzung der Probe gibt. Diese Arbeit ist im Teilprojekt I4S (Intelligenz für Böden) im Forschungsprogramm BonaRes (Boden als nachhaltige Ressource für die Bioökonomie) des Bundesministerium für Bildung und Forschung (BMBF) entstanden. Es wurden insgesamt 651 Bodenproben von verschiedenen Test-Agrarflächen unterschiedlichster Standorte Deutschlands gemessen, ausgewertet und zu Validierungszwecken mit entsprechender Referenzanalytik wie die Optische Emissionsspektroskopie mittels induktiv gekoppeltem Plasma (ICP-OES) und die wellenlängendispersive Röntgenfluoreszenzanalyse (WDRFA) charakterisiert. Für die Quantifizierung wurden zunächst die Messparameter des LIBS-Systems auf die Bodenmatrix optimiert und für die Elemente geeignete Linien ausgewählt sowie deren Nachweisgrenzen bestimmt. Es hat sich gezeigt, dass eine absolute Quantifizierung basierend auf einem univariaten Ansatz aufgrund der starken Matrixeffekte und der schlechten Reproduzierbarkeit des Plasmas nur eingeschränkt möglich ist. Bei Verwendung eines multivariaten Ansatz wie der Partial Least Squares Regression (PLSR) für die Kalibrierung konnten für die Nährelemente im Vergleich zur univariaten Variante Analyseergebnisse mit höherer Güte und geringeren Messunsicherheiten ermittelt werden. Die Untersuchungen haben gezeigt, dass das multivariate Modell weiter verbessert werden kann, indem mit einer Vielzahl von gut analysierten Böden verschiedener Standorte, Bodenarten und einem breiten Gehaltsbereich kalibriert wird. Mithilfe der Hauptkomponentenanalyse (PCA) wurde eine Klassifizierung der Böden nach der Textur realisiert. Weiterhin wurde auch eine Kalibrierung mit losem Bodenmaterial erstellt. Trotz der Signalabnahme konnten für die verschiedenen Nährelemente Kalibriergeraden mit ausreichender, analytischer Güte erstellt werden. Für den Einsatz auf dem Acker wurde außerdem der Einfluss von Korngröße und Feuchtigkeit auf das LIBS-Signal untersucht. Die unterschiedlichen Korngrößen haben nur einen geringen Einfluss auf das LIBS-Signal und das Kalibriermodell lässt sich durch entsprechende Proben leicht anpassen. Dagegen ist der Einfluss der Feuchtigkeit deutlich stärker und hängt stark von der Bodenart ab, sodass für jede Bodenart ein separates Kalibriermodell für verschiedene Feuchtigkeitsgehalte erstellt werden muss. Mithilfe der PCA kann der Feuchtigkeitsgehalt im Boden grob abgeschätzt werden und die entsprechende Kalibrierung ausgewählt werden. Diese Arbeit liefert essentielle Informationen für eine Echtzeit-Analyse von Nährelementen auf dem Acker mittels LIBS und leistet einen wichtigen Beitrag zu einer fortschrittlichen und zukunftsfähigen Nutzung von Ackerflächen. KW - Boden KW - Chemometrie KW - LIBS KW - Nährelemente KW - Düngeempfehlung KW - Precision Agriculture KW - Prozessanalytik PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:517-opus4-476772 DO - https://doi.org/https://doi.org/10.25932/publishup-47677 SP - 1 EP - 130 PB - Universität Potsdam CY - Potsdam AN - OPUS4-52183 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Erler, A. A1 - Riebe, D. A1 - Beitz, T. A1 - Löhmannsröben, H.-G. A1 - Leenen, M. A1 - Pätzold, S. A1 - Ostermann, Markus A1 - Wójcik, M. T1 - Mobile Laser-Induced Breakdown Spectroscopy for Future Application in Precision Agriculture—A Case Study N2 - In precision agriculture, the estimation of soil parameters via sensors and the creation of nutrient maps are a prerequisite for farmers to take targeted measures such as spatially resolved fertilization. In this work, 68 soil samples uniformly distributed over a field near Bonn are investigated using laser-induced breakdown spectroscopy (LIBS). These investigations include the determination of the total contents of macro- and micronutrients as well as further soil parameters such as soil pH, soil organic matter (SOM) content, and soil texture. The applied LIBS instruments are a handheld and a platform spectrometer, which potentially allows for the single-point measurement and scanning of whole fields, respectively. Their results are compared with a high-resolution lab spectrometer. The prediction of soil parameters was based on multivariate methods. Different feature selection methods and regression methods like PLS, PCR, SVM, Lasso, and Gaussian processes were tested and compared. While good predictions were obtained for Ca, Mg, P, Mn, Cu, and silt content, excellent predictions were obtained for K, Fe, and clay content. The comparison of the three different spectrometers showed that although the lab spectrometer gives the best results, measurements with both field spectrometers also yield good results. This allows for a method transfer to the in-field measurements KW - LIBS KW - Precision agriculture KW - Soil KW - Multivariate methods KW - Feature selection PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580777 DO - https://doi.org/10.3390/s23167178 VL - 23 IS - 16 SP - 1 EP - 17 PB - MDPI AG CY - Basel, Schweiz AN - OPUS4-58077 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Maher, C. A1 - Schazmann, B. A1 - Gornushkin, Igor B. A1 - Rurack, Knut A1 - Gojani, Ardian T1 - Exploring an Application of Principal Component Analysis to LaserInduced Breakdown Spectroscopy of Stainless-Steel Standard Samples as a Research Project N2 - Laser-induced breakdown spectroscopy (LIBS) and principal component analysis (PCA) are frequently used for analytical purposes in research and industry, but they seldom are part of the chemistry Curriculum or laboratory exercises. This case study paper describes the combined application of LIBS and PCA during a research internship for an undergraduate student. The instructional method applied was based on a one-on-one mentorship, in which case the learner was engaged in a Research work. The learning activities included theoretical introductions to the LIBS and PCA methods, numerical simulation, experiments, and data analysis. The study covered three main topics: analysis of LIBS spectra, application of PCA for clustering, and use of PCA for experimental design. The realization of the study was instructive for all parties involved: from the mentorship point of view, it is concluded that the topics can be covered during an internship or developed into a one semester long research-based module of a chemistry program or a final year project. The student, on the other hand, developed profound technical skills in performing experiments and using PCA software for data analysis. KW - LIBS KW - PCA PY - 2021 DO - https://doi.org/10.1021/acs.jchemed.1c00563 VL - 98 SP - 3237 EP - 3244 PB - American Chemical Society Publications CY - USA AN - OPUS4-53515 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Taparli, Ugur Alp A1 - Kannengießer, Thomas A1 - Cieslik, K. A1 - Mory, D. A1 - Griesche, Axel T1 - In situ chemical composition analysis of a tungsten-inert-gas austenitic stainless steel weld measured by laser-induced breakdown spectroscopy N2 - The chemical composition of a weld metal determines the resulting solidification mode of stainless steel and the consequent weld metal quality. In this work tungsten inert gas (TIG) welding of EN grade 1.4435 austenitic stainless steel was monitored using laser-induced breakdown spectroscopy (LIBS) for the in situ measurement of chemical composition changes. This research aims to prototype a real-time chemical composition analysis system for welding applications and prove the feasibility of such quality control loop. LIBS was used to investigate in situ the monitoring of metal vaporization during TIG welding. We found Mn vapor formation above the weld pool and subsequent condensation of Mn on the weld metal surface using LIBS. Post-weld line scans were conducted by LIBS on various welds produced with different welding currents. Local changes of Ni and Mn were observed at higher welding currents. The results are in good agreement with the literature and proved that LIBS can be used in situ to inspect the TIG welding process. T2 - 10th Euro-Mediterranean Symposium on Laser-Induced Breakdown Spectroscopy CY - Brünn, Czechia DA - 08.09.2019 KW - LIBS KW - Welding KW - Austenitic stainless steel KW - Metal vapor KW - In situ measurement PY - 2020 DO - https://doi.org/10.1016/j.sab.2020.105826 SN - 0584-8547 VL - 167 SP - 105826 PB - Elsevier B.V. CY - Amsterdam, Niederlande AN - OPUS4-50582 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. T1 - Modeling and diagnostics of laser induced plasma for needs of spectrochemical analysis N2 - Two topics will be addressed: (1) calibration-free LIBS based on Monte Carlo spectral optimization and (2) insight into the possibility of simultaneous elemental and molecular analysis by LIBS. Both topics heavily rely on modeling of laser induced plasma and are closely connected to experiment. In Monte Carlo LIBS (MC LIBS), concentrations are found by fitting model-generated synthetic spectra to experimental spectra. The model of a static uniform isothermal plasma in local thermodynamic equilibrium is employed. Many configurations of plasma parameters and their corresponding spectra are simultaneously generated using a graphic processing unit (GPU). Using the GPU allows for the reduction of computational time down to several minutes for one experimental spectrum that presents the significant progress in comparison with earlier versions of MC LIBS. The method is tested by analyzing industrial oxides containing various concentrations of CaO, Fe2O3, MgO, and TiO2. The agreement within several percent between found and certified concentrations is achieved. Next, a newly developed collisional-dominated model of a laser induced plasma is introduced. The model includes the coupled Navier-Stokes, state, radiative transfer, and material transport equations and incorporates plasma chemistry through the equilibrium approach based on the use of atomic and molecular partition functions. Simple chemical systems are modeled including ablation of Si and C in N2 and Ar atmospheres.The model is used to study evolution of number densities of atomic and molecular species in the expanding plasma plume. The distribution is compared to experimental observations obtained by optical imaging and tomography. To further verify the model, dynamic plasma T2 - FLAMN 2016 CY - St. Petersburg, Russia DA - 27.06.2016 KW - Plasma diagnostics KW - Laser induced plasma KW - LIBS KW - Plasma modeling PY - 2016 AN - OPUS4-38775 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Blaschke, Jil T1 - Laser Induced Breakdown Spectroscopy (LIBS) for the chemical investigation of concrete - Status of practical application and regulations in Germany N2 - Laser-Induced Breakdown Spectroscopy (LIBS) is an advanced, yet still underutilized, analytical technique that has gained increasing recognition for its potential in evaluating cementitious materials. Over the past several years, LIBS has demonstrated exceptional capabilities in providing detailed insights into the microstructural and chemical properties of concrete, with particular relevance to durability studies and service life assessment. One of the defining features of LIBS is its high spatial resolution, which enables precise mapping of ion transport processes within the binder matrix. This ability is critical for understanding concrete behavior under diverse environmental and operational conditions, such as chloride ingress, sulfate attack, or carbonation. By allowing the simultaneous detection of multiple elements, LIBS is uniquely suited for investigating complex interactions, including the co-migration of ions. Such comprehensive analyses yield detailed ion ingress profiles, improving the accuracy of key input parameters used in service life models. As a result, LIBS contributes to more reliable predictions of a structure's remaining lifespan and its susceptibility to environmental degradation. In addition to ion profiling, LIBS is particularly effective in identifying local anomalies that would otherwise not be detected by conventional methods. For instance, LIBS can reveal zones of elevated ion concentration in microcracks or other vulnerable regions, offering critical insights into structural integrity. LIBS supports the assessment of repair processes not only during application but also over long-term monitoring periods, thus contributing to the optimization of rehabilitation strategies. This presentation showcases a series of practical applications of LIBS in the laboratory analysis of building materials, supported by extensive comparative studies. Case studies highlight LIBS's transformative role in repair planning and decision-making, emphasizing its capacity to revolutionize infrastructure monitoring and maintenance. T2 - NDT-CE 2025 CY - Izmir, Türkiye DA - 24.09.2025 KW - LIBS KW - Concrete analysis KW - Ion transport profiling KW - Structural durability assessment PY - 2025 AN - OPUS4-64294 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dalichow, Dirk A1 - Blaschke, Jil A1 - Wilsch, Gerd A1 - Völker, Tobias T1 - Revolutionizing Concrete Analysis and Maintenance with Laser-Induced Breakdown Spectroscopy N2 - Laser-induced breakdown spectroscopy (LIBS) is a valuable complement to established methods for the chemical analysis of concrete. Compared to conventional techniques, LIBS enables spatially resolved imaging of harmful ion distributions within the cementitious matrix. It allows the simultaneous detection of all relevant ions and degradation mechanisms, facilitating a better understanding of interacting processes. The benefits of multi-element analysis are illustrated through selected examples that highlight the method’s superior information content. Ion penetration profiles are recorded at a resolution of 0.25 mm, providing high-quality input data for service life modelling. Instead of drill dust, a 50 mm core sample is used. The measurement is automated, requires no chemical reagents or elaborate sample preparation, and is completed within minutes. KW - LIBS KW - Durability KW - Ion transport profiling KW - Concrete analysis KW - Service life assessment PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-642846 DO - https://doi.org/10.58286/31656 SN - 1435-4934 VL - 30 IS - 10 SP - 1 EP - 8 PB - NDT.net GmbH & Co. KG AN - OPUS4-64284 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Is LIBS ready for the future? N2 - Recent years have brought up many challenges for an analytical tracing of material flows. While planetary boundaries force end of life material into circular recycling pathways, geopolitical tension creates demands regarding the origin of raw materials. The analytical demands on any instrumentation to tackle the arising challenges of this scenario are straight forward: No sample preparation, precision in the percentage region, and high throughput at comparably low cost. All these demands make LIBS a perfect candidate, why it is time for a re-evaluation of how it exploits the potential possibilities arising from todays’ technology. While being a relatively young technique, the vast majority of conducted LIBS experiments still relies on well established instrumentation, sometimes ignoring the innovations and breakthroughs in the development of its empowering technology sectors such as battery powered compact high repetition rate lasers with tuneable pulse rate and length, low priced cameras with millions of small sized pixels and extremely fast shutter and readout times, optical modulators, galvonometer scanners, and simple robotics. In this talk we will showcase some examples on how the implantation of all these new tools can lead to extremely affordable and compact instrumentation with unprecedented acquisition speed and a spectral resolution sufficient to resolve atomic isotope lines. T2 - FACCS SCiX CY - Raleigh, NC, USA DA - 20.10.2024 KW - LIBS KW - Isotopes KW - Instrumentation PY - 2024 AN - OPUS4-61970 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Riedel, Jens A1 - Hufgard, Josefin A1 - You, Yi T1 - LIBS at high duty-cycles: effect of repetition rate and temporal width on the excitation laser pulses N2 - Laser-induced breakdown spectroscopy (LIBS) is becoming a more mature technology every year with new variants such as laser ablation molecular isotopic spectrometry, reheating by various discharge techniques, and multiple pulse excitation schemes, in which sometimes lasers of different pulse lengths are used. However, lasers with inherent parameters like pulse length and repetition rate are still almost exclusively employed. Recent years have witnessed the advent of novel high-repetition-rate laser concepts for machining processes, like welding, milling, and engraving. Here, a comprehensive study of single-pulse LIBS spectra of a single aluminum target is presented to showcase the applicability of flexible high duty-cycle master oscillator power amplifier (MOPA) lasers. Although traditional flashlamp-pumped Fabry–Pérot lasers only permit a variation in the pulse energy and are operated at very low duty-cycles, MOPA lasers add repetition rate and pulse length as variable parameters. A thorough analysis of the temporal plasma behavior revealed the emission dynamic to closely match the excitation laser pulse pattern. An aluminum sample’s spectral response was shown to be significantly impacted by variations in both rate and length. Although the spectral emission strength of the elemental lines of Al, Sr, and Ca all peaked at slightly different parameter settings, the strongest impact was found on the relative abundance of molecular AlO bands. Unlike in previous laser ablation molecular isotopic spectrometry (LAMIS) publications, the latter could be readily detected with a good intensity and well-resolved spectral features without any temporal gating of the detector. This finding, together with the fact that MOPA lasers are both inexpensive and dependable, makes for a promising combination for future studies including the detection of diatomic band structures. KW - Laser-induced breakdown spectroscopy KW - LIBS PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-583300 DO - https://doi.org/10.3389/fphy.2023.1241533 SN - 2296-424X VL - 11 SP - 1 EP - 8 AN - OPUS4-58330 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Xue, Boyang A1 - Wang, Zhangjun A1 - Zhu, Tao A1 - Gu, Yezhen A1 - Sun, Weihong A1 - Chen, Chao A1 - Li, Zhigang A1 - Riedel, Jens A1 - You, Yi T1 - High repetition-rate laser-induced breakdown spectroscopy combined with two-dimensional correlation method for analysis of sea-salt aerosols N2 - Laser-induced breakdown spectroscopy (LIBS) offers a tantalizing glimpse into real-time, on-the-spot aerosol analysis. Yet, the reliance on traditional lasers, with their limitations in energy and frequency, hampers optimal sample handling, dissociation, and excitation. To address those challenges, we propose a novel tactic: utilize a high repetition-rate (rep.-rate) laser with low pulse energy in combination with the two-dimensional correlation (2D-corr.) technique for sea-salt aerosols analyses. By examining the emission patterns from both the laser pulse train and individual pulses, we recognize distinctive analyte-specific rep.-rate responses, which allowed spectral reconstruction of analytes, avoiding background interferences. This discovery enabled the rep.-rate modulation for a 2D-corr. spectroscopy workflow. Consequently, we successfully differentiated between particle-related and air-species-related spectral components, obviating expensive spectrometers or intensified image detectors. For instance, the Na I at 589 nm stemming from aerosols exhibited an entirely different correlation contribution compared to O I at 777 nm, resulting in reconstructed clean aerosol-spectra without spectral peaks originated from air species. This 2D-corr. aerosol LIBS approach shows promising analytical potential streamlining aerosol particle analysis. KW - LIBS KW - Aerosol PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-613392 DO - https://doi.org/10.1016/j.sab.2024.107048 SN - 0584-8547 VL - 221 SP - 1 EP - 8 PB - Elsevier AN - OPUS4-61339 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -