TY - THES A1 - Ecke, Alexander T1 - Integrated Diagnostics of Pharmaceutical Contaminants in Water Supply and Management Systems N2 - The contamination of drinking water with pharmaceuticals represents a severe health risk. In order to monitor the drinking water quality continuously and enable quick countermeasures in case of contamination, novel sensors are required. Here, immunoanalytical methods based on the binding of the analyte to highly selective antibodies can be helpful. In this work, magnetic bead-based immunoassays (MBBAs) have been developed for the detection of two relevant contaminants of drinking water: diclofenac (DCF) and amoxicillin (AMX). In case of the latter, not only the parent drug is of interest in the risk assessment but also its hydrolysis products (HPs). In a comprehensive study, the influence of external factors and intrinsic properties of the water on the rate of hydrolysis was investigated. As the hydrolysis of AMX further impacts the recognition by the antibody, a strategy to analyze samples with unknown hydrolysis degree of AMX was established employing the enzyme β-lactamase in sample preparation. For both analytes, the MBBAs enable the fast quantification with results obtained in less than one hour which represents a major improvement over conventional immunoassays like the enzyme-linked immunosorbent assay (ELISA). Compared to the respective ELISAs with the same antibodies, the MBBAs further exhibit improved analytical parameters such as a broader measurement range and lower limits of detection. Due to the magnetic properties of the beads that serve as a platform for the assays, they are suitable for the mobile and automated detection at the point-of-care. An integrated diagnostic system was designed in which electrochemical detection with chronoamperometry on a microfluidic chip allows for further miniaturization of the system to enable monitoring of the drinking water quality online in water supply pipes at waterworks. N2 - Die Kontamination von Trinkwasser mit Arzneimitteln stellt eine ernste Gesundheitsgefahr dar. Um die Trinkwasserqualität kontinuierlich überwachen und im Falle einer Verunreinigung zeitnah reagieren zu können, sind neuartige Sensoren erforderlich. Hier können immunanalytische Methoden, die auf der Bindung des Analyten an hochselektive Antikörper beruhen, hilfreich sein. In dieser Arbeit wurden magnetpartikelbasierte Immunoassays (MBBAs) für zwei relevante Kontaminanten des Trinkwassers entwickelt: Diclofenac (DCF) und Amoxicillin (AMX). Bei letzterem erwiesen sich neben der Ausgangsverbindung auch dessen Hydrolyseprodukte (HPs) als relevant für die Gefährdungsbeurteilung. In einer umfassenden Studie wurde der Einfluss von externen Faktoren und intrinsischen Eigenschaften des Wassers auf die Hydrolysegeschwindigkeit untersucht. Da die Hydrolyse von AMX auch die Erkennung durch den Antikörper beeinflusst, wurde eine Strategie zur Analyse von Proben mit unbekanntem Hydrolysegrad von AMX unter Verwendung des Enzyms β-Lactamase in der Probenvorbereitung entwickelt. Für beide Analyten ermöglichen die MBBAs eine schnelle Quantifizierung mit Ergebnissen in weniger als einer Stunde, was eine wesentliche Verbesserung gegenüber herkömmlichen Immunoassays wie dem Enzyme-linked Immunosorbent Assay (ELISA) darstellt. Im Vergleich zu den entsprechenden ELISAs mit denselben Antikörpern weisen die MBBAs zudem verbesserte analytische Parameter auf, wie einen breiteren Messbereich und niedrigere Nachweisgrenzen. Aufgrund der magnetischen Eigenschaften der Partikel, die als Plattform für die Assays dienen, eignen sie sich für den mobilen und automatisierten Einsatz vor Ort. Ein integriertes Diagnosesystem, bei dem die elektrochemische Detektion mittels Chronoamperometrie auf einem mikrofluidischen Chip eine weitere Miniaturisierung des Systems ermöglicht, wurde entworfen, um die Überwachung der Trinkwasserqualität online in Wasserwerken zu ermöglichen. KW - Antibiotics KW - Immunoassay KW - Amoxicillin KW - Diclofenac KW - Biosensor KW - Antibodies PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-591901 SP - 1 EP - 129 CY - Berlin AN - OPUS4-59190 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Riedel, Soraya T1 - Development of electrochemical antibody-based and enzymatic assays for mycotoxin analysis in food N2 - Electrochemical methods are promising to meet the demand for easy-to-use devices monitoring key parameters in the food industry. Many companies run own lab procedures for mycotoxin analysis, but it is a major goal to simplify the analysis. The enzyme-linked immunosorbent assay using horseradish peroxidase as enzymatic label, together with 3,3',5,5' tetramethylbenzidine (TMB)/H2O2 as substrates allows sensitive mycotoxin detection with optical detection methods. For the miniaturization of the detection step, an electrochemical system for mycotoxin analysis was developed. To this end, the electrochemical detection of TMB was studied by cyclic voltammetry on different screen-printed electrodes (carbon and gold) and at different pH values (pH 1 and pH 4). A stable electrode reaction, which is the basis for the further construction of the electrochemical detection system, could be achieved at pH 1 on gold electrodes. An amperometric detection method for oxidized TMB, using a custom-made flow cell for screen-printed electrodes, was established and applied for a competitive magnetic bead-based immunoassay for the mycotoxin ochratoxin A. A limit of detection of 150 pM (60 ng/L) could be obtained and the results were verified with optical detection. The applicability of the magnetic bead-based immunoassay was tested in spiked beer using a handheld potentiostat connected via Bluetooth to a smartphone for amperometric detection allowing to quantify ochratoxin A down to 1.2 nM (0.5 µg/L). Based on the developed electrochemical detection system for TMB, the applicability of the approach was demonstrated with a magnetic bead-based immunoassay for the ergot alkaloid, ergometrine. Under optimized assay conditions a limit of detection of 3 nM (1 µg/L) was achieved and in spiked rye flour samples ergometrine levels in a range from 25 to 250 µg/kg could be quantified. All results were verified with optical detection. The developed electrochemical detection method for TMB gives great promise for the detection of TMB in many other HRP-based assays. A new sensing approach, based on an enzymatic electrochemical detection system for the mycotoxin fumonisin B1 was established using an Aspergillus niger fumonisin amine oxidase (AnFAO). AnFAO was produced recombinantly in E. coli as maltose-binding protein fusion protein and catalyzes the oxidative deamination of fumonisins, producing hydrogen peroxide. It was found that AnFAO has a high storage and temperature stability. The enzyme was coupled covalently to magnetic particles, and the enzymatically produced H2O2 in the reaction with fumonisin B1 was detected amperometrically in a flow injection system using Prussian blue/carbon electrodes and the custom-made wall-jet flow cell. Fumonisin B1 could be quantified down to 1.5 µM (≈ 1 mg/L). The developed system represents a new approach to detect mycotoxins using enzymes and electrochemical methods. N2 - Zur Entwicklung von einfach zu bedienenden Vor-Ort-Geräten, welche für die Analytik von wichtigen Parametern in der Lebensmittelindustrie eingesetzt werden können, sind elektrochemische Methoden besonders vielversprechend. Viele Unternehmen führen bereits Mykotoxinanalytik in eigenen Laboren am Produktionsstandort durch, dennoch gibt es große Bestrebungen Analysenmethoden weiter zu vereinfachen. Der Enzyme-linked Immunosorbent Assay (ELISA), welcher häufig mit der Meerrettichperoxidase als enzymatischem Label und 3,3',5,5'-Tetramethylbenzidine (TMB)/H2O2 als Enzymsubstraten arbeitet, ermöglicht den sensitiven Mykotoxinnachweis mithilfe optischer Detektionsmethoden. Zur Miniaturisierung des Detektionsschrittes wurde in dieser Arbeit der Aufbau von elektrochemischen Detektionssystemen für die Mykotoxinanalytik untersucht. Dazu wurde zunächst die elektrochemische Reaktion von TMB an verschiedenen Materialien siebgedruckter Elektroden (Kohlenstoff und Gold) sowie bei verschiedenen pH-Werten (pH 1 und pH 4) untersucht. Eine stabile Elektrodenreaktion, welche die Grundlage für den weiteren Aufbau des elektrochemischen Detektionssystems darstellt, konnte bei pH 1 an Goldelektroden erzielt werden. Basierend darauf wurde eine amperometrische Detektionsmethode für oxidiertes TMB entwickelt, wofür eine maßgefertigte Durchflusszelle verwendet wurde. Die amperometrische TMB-Detektion wurde für einen kompetitiven Magnetpartikel-basierten Immunoassay für Ochratoxin A eingesetzt. Mit diesem Assay wurde eine Nachweisgrenze von 150 pM (60 ng L-1) erreicht und die Ergebnisse konnten durch optische Detektion verifiziert werden. Die Anwendbarkeit des Assays konnte in Ochratoxin A dotiertem Bier demonstriert werden, wobei für die Detektion ein tragbarer Potentiostat verwendet wurde, welcher über Bluetooth mit einem Smartphone verbunden war. Hiermit konnten niedrige Ochratoxin A Konzentration von bis zu 1.2 nM (0.5 µg L-1) bestimmt werden. Aufbauend auf dem entwickelten elektrochemischen Detektionssystem für TMB wurde die Anwendbarkeit des Ansatzes auf einen Magnetpartikel-basierten Immunoassay für das Ergotalkaloid Ergometrine, evaluiert. Unter optimierten Bedingungen konnte mit dem Assay eine Nachweisgrenze von 3 nM (1 µg L-1) erreicht werden. In mit Ergometrin versetztem Roggenmehl konnten Konzentrationen von 25 bis 250 µg kg-1 nachgewiesen werden. Die entwickelte elektrochemische Nachweismethode für TMB bietet einen vielversprechenden Ansatz für den Einsatz in vielen anderen Meerrettichperoxidase-basierten Assays. Für das Mykotoxin Fumonisin B1, wurde ein neues sensorisches System entwickelt, welches auf einem enzymatischen elektrochemischen Nachweis basiert. Hierfür wurde eine Aspergillus niger Fumonisin Aminoxidase (AnFAO) rekombinant als Fusionsprotein mit dem Maltose-bindenden Protein exprimiert. AnFAO katalysiert die oxidative Deaminierung von Fumonisinen, wobei H2O2 gebildet wird. Es konnte gezeigt werden, dass AnFAO eine hohe Lagerungs- und Temperaturstabilität hat. Für den Nachweis von Fumonisin B1 wurde das Enzym kovalent an Magnetpartikel gekoppelt. Das enzymatisch produzierte H2O2 konnte anschließend amperometrisch mithilfe von Preußisch Blau/Kohlenstoff-Elektroden in der maßgefertigten Durchflusszelle detektiert werden. Fumonisin B1 konnte bis zu einer Konzentration von 1,5 µM (≈ 1 mg L-1) quantifiziert werden. Das entwickelte System stellt einen neuen Ansatz dar, um Mykotoxine unter Nutzung von Enzymen und elektrochemischen Methoden zu detektieren. KW - Mycotoxins KW - Biosensor KW - Antibodies KW - Electrochemical detection PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:517-opus4-607477 SP - 1 EP - 96 PB - Universität Potsdam CY - Potsdam AN - OPUS4-59189 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -