TY - CONF A1 - Radnik, Jörg T1 - Reliable Chemical Characterization Protocols for Industrial Graphene-Related Materials N2 - Since its isolation, graphene has received growing attention from academia and industry due to its unique properties. Promising opportunities for applications are discussed in different field like electronics and optoelectronics, detection, and sensing devices, biosystems or chemical and environmental corrosion inhibition. Here, functionalization with elements like oxygen, nitrogen or fluorine can broaden the application, for example in composite materials. However, lack of generally accepted operation procedures hinders the commercialization, the so-called “what is my material” barrier. Therefore, first efforts were done to develop common, reliable, and reproducible ways to characterize the morphological and chemical properties of the industrially produced material. In this contribution, our efforts in the development of reliable chemical characterizations protocols for functionalized graphene are presented. An ISO standard for the chemical characterization of graphene-related (GRM) is under development with X-ray photoelectron spectroscopy (XPS) having a prominent role. With its information depth of around 10 nm, which is the similar length scale as the thickness of particles of 2D materials consisting of a few monolayers, XPS seems to be highly suitable for the quantitative analysis of (functionalized) GRM. Thereby, different sample preparation methods like pressing the powders onto adhesive tapes, into recesses, or into solid pellets result in inconsistencies in the quantification. Furthermore, different morphologies like stacks of graphene layers (left figure) or irregular particles (right figure) lead to different analysis results for the chemical composition. For the validation of the quantification with XPS and the further development of standards an international interlaboratory comparison was initiated under the head of the “Versailles Project on Advanced Materials and Standards” (VAMAS). First results are reported showing the suitability of the protocols. Finally, the XPS results are compared with the elemental composition results obtained after quantification with energy-dispersive X-ray spectroscopy (EDS) as a fast analytical method which is usually combined with electron microscopy. T2 - nanoSAFE 2023 CY - Grenoble, France DA - 05.06.2023 KW - X-ray photoelectron spectroscopy KW - Functionalized graphene KW - Interlaboratory comparison KW - VAMAS PY - 2023 AN - OPUS4-57652 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Deep Insights into Functionalised Nanoparticles with Photoelectron Spectroscopy N2 - Modern instrumentation X-ray photoelectron instrumentation combines soft and hard X-rays. Additonally, in the last years methods were developed for the analysis of the measurement data to elucidate the composition and thickness of coatings of nanoparticles. In this presentation four examples will be presented: quantum dots, silica-coated iron-oxide nanoparticles, mixed Fe-Ni-O nanoparticles and amine-functionalized silica nanoparticles. These different nanoparticles are used for displays, for biomedicine, for water splitting, and as additives and fillers. T2 - United Kingdom Surface Analysis Forum Meeting 2025 CY - Teddington, UK DA - 15.07.2025 KW - Simulation KW - Oxygen evolution reaction KW - Transmission electron microscopy KW - Quantitative nuclear magnetic resonance (qNMR) PY - 2025 AN - OPUS4-63733 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - VAMAS Project A33: Chemical composition of functionalized graphene with X ray photoelectron spectroscopy (XPS) N2 - The results of the interlaboratory comparison about the chemical composition of functionalized graphene are presented. T2 - DIN Meeting NA 062-08-16 AA CY - Berlin, Germany DA - 25.05.2023 KW - X-ray photoelectron spectroscopy KW - Functionalized graphene KW - Interlaboratory comparison KW - VAMAS PY - 2023 AN - OPUS4-57650 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Analysis of Nanoparticles N2 - The determination of the thickness and composition of the coating is crucial for the understanding of the properties of nanoparticles. Four different approaches will be presented: (i) numerical methods, (ii) descriptive formulae, (iii) the simulation of spectra with Monte-Carlo methods, and (iv) inelastic background analysis. The advantages and limits of these methods will be discussed. T2 - XPS Workshop CY - Teddington, United Kingdom DA - 14.07.2025 KW - Numerical simulation KW - Emperical formulae KW - Simulation KW - Inelastic background analysis PY - 2025 AN - OPUS4-63732 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Correlating HR-TEM and XPS to elucidate the core-shell structure of ultrabright CdSE/CdS semiconductor quantum dots N2 - Controlling the thickness and tightness of surface passivation shells is crucial for many applications of core-shell nanoparticles (NP). Usually, to determine shell thickness, core and core/shell particle are measured individually requiring the availability of both nanoobjects. This is often not fulfilled for functional nanomaterials such as many photoluminescent semiconductor quantum dots (QD) used for bioimaging, solid state lighting, and display technologies as the core does not show the application-relevant functionality like a high photoluminescence (PL) quantum yield. This calls for a whole nanoobject approach. Moreover, the thickness of the organic coating remains often unclear. By combining high-resolution transmission electron microscopy (HR-TEM) and X-ray photoelectron spectroscopy (XPS), a novel whole nanoobject approach is developed representatively for an ultrabright oleic acid-stabilized, thick shell CdSe/CdS QD with a PL quantum yield close to unity. The size of this spectroscopically assessed QD, is in the range of the information depth of usual laboratory XPS. Information on particle size and monodispersity were validated with dynamic light scattering (DLS) and small angle X-ray scattering (SAXS) and compared to data derived from optical measurements. The results of the different methods match very well within the different measurement uncertainties. Additionally, results obtained with energy-resolved XPS using excitation energies between 200 eV and 800 eV are discussed with respect to a potential core/shell intermixing. Moreover, the future application potential of this approach correlating different sizing and structural methods is discussed considering the method-inherent uncertainties and other core/multi-shell nanostructures. T2 - E-MRS Fall Meeting CY - Online meeting DA - 20.09.2021 KW - Core-shell nanoparticles KW - Quantum dots KW - High-resolution transmission electron microscopy KW - X-ray Photoelectron Spectroscopy PY - 2021 AN - OPUS4-53365 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Interlaboratory comparisons for validated measurements of the surface chemistry of nanomaterials N2 - Interlaboratory comparisons are essential tools for validating new protocols or methods. The properties of advanced materials are largely determined by surface chemistry. Using a VAMAS interlaboratory comparison on the surface functionalization of GR2DM, it is explained what insights can be gained from such a comparison.” T2 - Nanomesure France Journee technique CY - Paris, France DA - 04.11.2025 KW - VAMAS KW - Functionalized graphene KW - X-ray photoelectron spectroscopy PY - 2025 AN - OPUS4-65002 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Reliable measurements of the chemical composition of graphene-related 2D materials with X-ray photoelectron spectroscopy N2 - Graphene and related 2D materials (GR2Ms) are now entering an exciting phase of commercialization and use in products. Graphene nanoplatelets (GNPs) can be obtained in rather large quantities, but the properties of these industrially produced powders can vary depending on the production method, and even from batch to batch. Understanding and optimizing the surface chemistry of GNPs, modified through chemical functionalization processes is crucial, because it affects their dispersibility in solvents and matrices for the purpose of embedding them into real-world products. Therefore, reliable and repeatable measurements of the surface chemistry of functionalized GNPs are an important issue for suppliers as well as users of these materials. To address these concerns, international documentary ISO standards for measurement methodologies are under development which incorporate protocols that are becoming widely accepted in the community. Recently, it was shown that pelletizing led to lower average O/C atomic ratios than those measured for powders [1]. In another study, the influence of the morphology on the degree of functionalization was shown [2]. As expected, a higher degree of functionalization was detected for smaller GNPs. The functionalization was located at the outermost surfaces of the GNPs by comparing experiments using photoelectron with soft (Al Kα, 1.486 keV) and hard X-rays (Cr Kα, 5.405 keV). Therefore, it is important for those using GNPs to understand both the physical and chemical properties of these particles, when considering their use in different applications. The next step for reliable characterization protocols was the realization of an interlaboratory comparison under the auspices of VAMAS (Versailles Project on Advanced Materials and Standards) with 22 participating laboratories from all over the world. Samples of oxygen-, nitrogen-, and fluorine- functionalized GNPs were provided to the participants along with a measurement protocol. Participants were asked to prepare the samples as powders on a tape, powders in a sample holder recess, or as pellets. The lower measured O/C ratio reported for pelletized samples [1] was confirmed. The lowest scattering of the results was observed for the powders measured in the recess (Fig. 1). Furthermore, an influence of the humidity on the results was observed. T2 - ECASIA 2024 CY - Gothenburg, Sweden DA - 09.06.2024 KW - Interlaboratory Comparison KW - Functionalized graphene KW - Sample preparation PY - 2024 AN - OPUS4-60533 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - ToF-SIMS at advanced materials - from nano to energy N2 - The basic principles of ToF-SIMS will be explained. Examples of the use of ToF-SIMS for the investigation of titania and core-shell nanoplastic will be given. Furhtermore, 3d reconstruction is explained for nanoparticle research and energy-related materials. T2 - BUA Summer School Mass Spectrometry CY - Berlin, Germany DA - 04.10.2022 KW - ToF-SIMS KW - Nanomaterials KW - Imaging PY - 2022 AN - OPUS4-55897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - MinimUm Information Requirements for Electron Microscopy and Surface analysis Data For Risk Assessment of Nanoforms N2 - The European legislation has responded to the wide use of nanomaterials in our daily life and defined the term “nanoform” in the Annexes to the REACH (Registration, Evaluation, Authorization of Chemicals) Regulation. Now specific information of the nanomaterials is required from the companies when registering the appropriate materials in a dossier. In the context of REACH eleven physicochemical properties were considered as relevant, of which the following six are essential for registration of nanoforms (priority properties): chemical composition, crystallinity, particle size, particle shape, chemical nature of the surface (“surface chemistry”), and specific surface area (SSA). A key role is the reliable, reproduceable and traceable character of the data of these priority properties. In this context, we want to discuss which ‘analytical’ information is exactly required to fulfill these conditions. Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and X-ray Photoelectron Spectroscopy (XPS) were chosen as the most popular surface analytical methods. Both methods allow a detailed understanding of the surface chemistry with an information depth below ten nanometers. As a rather bulk method for the analysis of nanoforms, Electron Probe Microanalysis (EPMA) in the version with energy dispersive X-ray spectroscopy (EDS) is considered for the quick identification of the main chemical elements present in the sample. Furthermore, Scanning Electron Microscopy (SEM) results are discussed which provide results on particle size and shape. Thus, four of the six priority properties can be obtained with these methods. T2 - Nanosafe 2020 CY - Online meeting DA - 17.11.2020 KW - Risk assessment KW - Nanomaterials KW - Standardization KW - Regulation PY - 2020 AN - OPUS4-51612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Comprehensive characterization of Al-coated titania nanoparticles with electron microscopy and surface chemical analytics N2 - The wide use of nanoforms with at least one dimension below 100 nm in our daily life requires a detailed knowledge of their physicochemical properties which are needed for risk assessment or quality control. Therefore, a comprehensive characterization of these properties was considered as relevant including: chemical composition, crystallinity, particle size, particle shape, surface chemistry, and specific surface area (SSA). We want to discuss, how Scanning Electron Microscopy (SEM), Electron Probe Microanalysis (EPMA) in the version with energy dispersive X-ray spectroscopy (EDS), Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) and X-ray Photoelectron Spectroscopy (XPS) can contribute to gain comprehensive insights into the nature of the nanoparticles. SEM results provide the particle size and shape (distribution). A quick identification of the main chemical elements present in the sample can be obtained with EDS, whereas XPS allows a more detailed chemical identification of the small nanoparticles below 20 nm or of the near-surface region of larger particles. ToF-SIMS is even much more surface-sensitive and leads to a deeper understanding of the surface chemistry of the nanoparticles. As exemplary samples, two Al-coated TiO2 samples in nanopowder form were chosen from the JRC repository, capped either with a hydrophilic or a hydrophobic organic shell. A focus of our case study was to show, how reliable, reproducible and traceable data can be obtained. Therefore, each step in the workflow of sample investigation must be described in detail. For the most of these steps, well-established standards are available. Usually, the conditions of the particular measurements with each analysis method are saved as meta-data in the common file formats. But other factors like sample preparation and data reduction approaches may influence the result of the investigations in a significant manner and must be described often in a separate file (as a protocol) together with the data file. For sensitive materials like nanoobjects, the preparation of the sample influences the results crucially, e.g. measured as suspension or as powders. Furthermore, data reduction like selection of relevant peaks in spectra or particles in images, background subtraction, peak deconvolution, models for the quantification of the spectra must be considered in the interpretation of the results ideally with associated individual measurement uncertainties. Only a detailed description of all these factors allows to obtain a comprehensive characterization with reliable, reproduceable and traceable data. Examples of standardized procedures of measurement or on data reduction will be highlighted. We thank for the funding from the European Unions’s Horizon 2020 for the project NanoSolveIt (grant agreement No. 814572) and for the project NANORIGO (grant agreement No. 814530). T2 - E-MRS Spring Meeting CY - Online meeting DA - 31.05.2021 KW - Scanning Electron Microscopy KW - Energy dispersive X-ray spectroscopy KW - Time-of-Flight Secondary Ion Mass Spectrometry KW - X-ray Photoelectron Spectroscopy KW - Titania nanoparticles PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527486 AN - OPUS4-52748 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Characterization of functionalized graphene particles with comparative XPS/HAXPES investigations N2 - The different chmemistry of graphitic nanoplatelets between the outermost surface and the bulk of the samples was investigated with comparative XPS/HAXPES measurements. T2 - PHI User Meeting CY - Grenoble, France DA - 18.04.2023 KW - X-ray photoelectron spectroscopy KW - Hard-energy X-ray photoelectron spectroscopy KW - graphene related 2D materials PY - 2023 AN - OPUS4-57649 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - How to perform reliable xps-measurements? N2 - Reliable measurements are a great challenge in X-ray photoelectron spectroscopy. It will be shown, how to check the performance and calibration of the instrument, the charge compensation, quantification, fitting, and depth profiling. T2 - Course for PhD students at SFB 1073 CY - Göttingen, Germany DA - 23.02.2024 KW - X-ray photoelectron spectroscopy KW - Reproducibility crisis KW - Reliability PY - 2024 AN - OPUS4-59590 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - XPS of GR2M N2 - The activities of ISO-G-Scope are presented. The influence of the sample preparation and the results of XPS/HAXPES measurements are discussed. T2 - Graphene Workshop @ ISO TC 229 Meeting CY - Teddington, UK DA - 16.11.2022 KW - Graphene related materials KW - X-ray photoelectron spectroscopy KW - Sample preparation KW - Hard X-ray photoelectron spectroscopy PY - 2022 AN - OPUS4-56434 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - How to measure the chemical composition of industrial graphene - New insights from an interlaboratory comparison N2 - International standards describing reliable protocols will facilitate the commercialization of graphene and related 2D materials. One physico-chemical key property next to flake size and thickness is the chemical composition of the material. Therefore, an ISO standard is under development with X-ray photoelectron spectroscopy having a prominent role. With its information depth of around 10 nm which is the similar length scale as the thickness as of particles of 2D materials consisting of a few monolayer XPS seems to be highly suitable for this purpose. Different sample preparation methods like pressing the powders onto adhesive tapes, into recesses, or into solid pellets result in inconsistencies in the quantification. For the validation of the quantification with XPS an interlaboratory comparison was initiated under the auspice of the “Versailles Project on Advanced Materials and Standards” (VAMAS). First results confirm that the sample preparation method (pellet vs. powder) influences the quantification results clearly. T2 - Characterization of Nanomaterials Colloquium CY - Berlin, Germany DA - 04.07.2023 KW - X-ray photoelectron spectroscopy KW - Functionalized graphene KW - Interlaboratory comparison PY - 2023 AN - OPUS4-57897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - In depth analysis of commercial functionalized graphene nanoplateles towards structure-activity relationships N2 - The analysis of commercial graphene related products from the raw material to inks is discussed and the input to structure-activity relationships. Different approaches to obtain structure-activity relationships like operando or using data mining are presented. Challenges and recommendation to obtain structure-activity relationships are given. T2 - Joint Regulator Risk Summit: Advancing Safety & Sustainability Assessments of Advanced Materials CY - Paris, France DA - 19.06.2025 KW - Functionalized graphene KW - Structure activity relationsships KW - Commercialisation PY - 2025 AN - OPUS4-63565 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Graphene Week - Training Session: Standardisation and Validation N2 - In this training session the standardisation landscape will be presented. Another focus is how science can put into standards. In the second part the validation of protocols will be validated. Reference materials and interlaboratory comparisons as validation tools will be discussed. T2 - Graphene Week 2024 CY - Prague, Czech Republic DA - 14.10.2024 KW - Precision KW - Trueness KW - Accuracy KW - Interlaboratory comparison KW - Certified reference materials PY - 2024 AN - OPUS4-61469 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - The next steps in the standardisation of graphene-related and other 2D materials (GR2M) N2 - The first products with graphene-related 2D material (GR2M) are on the market. In this phase trust is essential for the commercial success of these products, between the individual partners of the product value chain, and between the manufacturer and the consumer. Standards are an important tool for building this trust. The first steps have been taken in standardisation, e.g. in terminology and the characterization of raw materials. But there are still some challenges to overcome such as bringing the standards to the factory floor and real-world products. For the validation of new protocols and methods there is a need of reference data and materials. But not only the measurement should be reproducible, the whole analytical workflow from sample storage and preparation to data analysis should be reproducible. Another important issue is the establishment of credible structure-activity relationships which allows the prediction of the properties of the GR2M, but also of the biological activity including the safety for the human health and the environment. Such relationships can be used for read-across and grouping and can facilitate the regulation of the advanced materials. In addition, 2D materials beyond graphene should also be considered and can benefit from the experience from the standardisation of graphene and graphene oxide. T2 - Nanomaterials Standardization Strategy Forum - Europe - Republic of Korea CY - Online meeting DA - 08.07.2025 KW - Commercialisation KW - Product-value chain KW - Confidence building PY - 2025 AN - OPUS4-63731 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Reliable chemical characterization of industrial graphene related materials N2 - International standards describing reliable protocols will facilitate the commercialization of graphene and related 2D materials. One physico-chemical key property next to flake size and thickness is the chemical composition of the material. Therefore, an ISO standard is under development with X-ray photoelectron spectroscopy having a prominent role. With its information depth of around 10 nm which is the similar length scale as the thickness as of particles of 2D materials consisting of a few monolayer XPS seems to be highly suitable for this purpose. Different sample preparation methods like pressing the powders onto adhesive tapes, into recesses, or into solid pellets result in inconsistencies in the quantification. For the validation of the quantification with XPS an interlaboratory comparison was initiated under the auspice of the “Versailles Project on Advanced Materials and Standards” (VAMAS). First results confirm that the sample preparation method (pellet vs. powder) influences the quantification results clearly. Considering this effect, a good agreement of the results from the different participants were observed. Similar results were observed for raw, N- and F-functionalized graphene. T2 - Graphene CY - Manchester, England, UK DA - 27.06.2023 KW - X-ray photoelectron spectroscopy KW - Functionalized graphene KW - Interlaboratory comparison KW - VAMAS PY - 2023 AN - OPUS4-57895 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Interlaboratory comparisons as tool in advanced materials characterisation N2 - Interlaboratory comparisons (ILCs) are an important tool for the validation of characterisation methods, and, herwith, a prerequisite for standardisation. The "Versailles Project on Advanced Materials and Standards" offers a framework for performing such ILCs: (i) TiO2 nanoparticles using ToF-SIMS, and (ii) the chemical composition of functionalized graphene using XPS. The results of both ILCs underline the importance of sample preparation for the measured results. T2 - NanoMeasure France Meeting CY - Online meeting DA - 07.06.2024 KW - Standardisation KW - Validation KW - Interlaboratory comparison KW - Graphene related 2D materials KW - Titania nanoparticles PY - 2024 AN - OPUS4-60532 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - How to expand the use of your test method? Validation is key towards standardisation N2 - Standardised methods need validation. The main validation parameters like trueness, repeatability and intermediate precision and reproducibility are presented. Furthermore, different methods for the validation are disussed: (certified) reference materials, representative testing materials and interlaboratory comparisons. At last, the need of proficiency testing is stressed. T2 - Materials Week 2024 CY - Limassol, Cyprus DA - 17.06.2024 KW - Validation KW - Reproducibility crisis KW - Metrological traceability KW - Measurement uncertainty PY - 2024 AN - OPUS4-60536 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Analytical & Characterisation Excellence in nanomaterial risk assessment: A tiered approach N2 - The work packages of the EU H2020 project ACEnano are presented and their activities in standardization and guidance for regulators and SMEs. T2 - ISO/TC 229 Strategy meeting CY - Online meeting DA - 10.11.2020 KW - Nanomaterials KW - Standardization KW - Risk assessment PY - 2020 AN - OPUS4-51611 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Elucidating core shell nanostructures with surface analytics N2 - XPS is a versatile tool for elucidating core shell structures. XPS can obtain information for organic compounds (polymer particle, organic coating ) which are hardly or not detectable with other Methods. XPS is an important tool for the risk assessement of nanoparticles T2 - Kratos German User Meeting CY - Online meeting DA - 26.05.2021 KW - Core-shell nanoparticles KW - X-ray photoelectron spectroscopy KW - Complementary methods PY - 2021 AN - OPUS4-52717 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radnik, Jörg T1 - Advanced Materials for the Energy Transition N2 - Advanced Materials are crucial for the sucess of the energy transition. 10 relevant advanced materials were chosen and their role for relevant technologies was analysed. Challenges regarding their safe and sustainable use are discussed. T2 - OECD WPMN SG Advanced Materials Teleconference CY - Online meeting DA - 30.09.2025 KW - Solar Cells KW - Advanced Carbon Materials KW - Fuel Cells KW - Batteries KW - Hydrogen Storage PY - 2025 AN - OPUS4-64306 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rahner, E. T1 - From nightmare to numbers - A novel software tool for objective regularity analysis of LIPSS N2 - The precise laser-based surface structuring on the micro- and nanoscale allows for the creation of functional properties for innovative applications, e.g., in medicine, optics and biology. Among the various types of surface structures, laser-induced periodic surface structures (LIPSS) are distinguished by their versatility and the comparatively simple manufacturing process. Nevertheless, the fabrication of highly regular LIPSS patterns remains challenging. The systematic investigation of LIPSS formation, as well as of the resulting functional properties demands accurate and objective evaluation of surface morphology, especially regarding periodicity and regularity. Existing quantification methods such as Fast Fourier Transformation (FFT) tend to lack automation and objectivity, especially when dealing with large data sets and multi-scale structures. Although automated approaches, such as those based on the Gini coefficient or the P³S method, have been proposed, their limited availability hinders a broader scientific use. To overcome these limitations, we introduce ReguΛarity, a novel, freely available Python-based software tool featuring a graphical user interface for automated and quantitative assessment of regularity in period and (quasi-)periodic surface patterns including LIPSS. The software processes microscopic images obtained from optical, scanning electron microscopy (SEM), or atomic force microscopy (AFM), combining image segmentation with one- and two-dimensional Fourier analyses (1D-FT, 2D-FT), phase evaluation, and gradient-based orientation determination to facilitate a comprehensive regularity analysis of (quasi-)periodic surface patterns with spatial periods Λ. Regularity is quantified by the newly proposed five-dimensional regularity tuple R comprising the normalized spread of spatial periods from 2D-FT, the normalized local variation of the dominant spatial period from 1D-FT, the Gini coefficient G, the Dispersion of the LIPSS Orientation Angle (DLOA), and the mean phase deviation. The demonstration of the software’s capabilities is achieved by comparing idealized sinusoidal test patterns with SEM micrographs of fs-laser-generated LIPSS on stainless steel (AISI 316L) and aluminum alloy (AlMg5). This comparison highlights ReguΛarity’s objective differentiation between varying levels of structural regularity. The software facilitates high-throughput analysis and data-driven optimization in laser surface engineering processes. T2 - 13th International LIPSS Workshop CY - Enschede, Netherlands DA - 29.10.2025 KW - Laser-induced periodic surface structures (LIPSS) KW - Surface functionalization KW - Fourier transform KW - Gini coefficient PY - 2025 AN - OPUS4-65047 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ren, L. A1 - Pollard, A. A1 - Hodoroaba, Vasile-Dan T1 - Measurement of Lateral Size of Graphene Oxide Flakes by SEM - An Update of the VAMAS TWA 41 Project P13 N2 - The progress of the VAMAS interlaboratory comparison Project P13 "Lateral size of graphene oxide flakes by SEM" within the Technical Working Area 41 "Graphene and Related 2D Materials" is presented. The challenges at sample preparation on substrates for accurate measurement and image analysis as well as two different image analysis approaches, containing exact guidance how to measure the main descriptors for the lateral size measurement of the imaged graphene oxide flakes with Scanning Electron Microscopy are described. The implementation of the results into the corresponding ISO technical specification AWI/TS 23879 is also discussed and planned, in relation with the AFM part. T2 - Versailles Project on Advanced Materials and Standards (VAMAS) 49th Steering Committee Meeting CY - Rio de Janeiro, Brazil DA - 23.09.2024 KW - VAMAS KW - Graphene oxide KW - SEM KW - Lateral size KW - Interlaboratory comparison PY - 2024 UR - http://www.vamas.org/twa41/documents/2023_vamas_twa41_project13_GO_SEM.pdf AN - OPUS4-61434 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ren, L. A1 - Pollard, A. A1 - Hodoroaba, Vasile-Dan T1 - Measurement of Lateral Size of Graphene Oxide Flakes by SEM - An Update of the VAMAS TWA 41 Project P13 N2 - The progress of the VAMAS interlaboratory comparison Project P13 "Lateral size of graphene oxide flakes by SEM" within the Technical Working Area 41 "Graphene and Related 2D Materials" is presented. The challenges at sample preparation on substrates for accurate measurement and image analysis as well as two different image analysis approaches, containing exact guidance how to measure the main descriptors for the lateral size measurement of the imaged graphene oxide flakes with Scanning Electron Microscopy are described. Discrepancies are explained. The inclusion of the results into the corresponding ISO technical specification CD/TS 23879 is also discussed and planned, in relation with the AFM part. T2 - Versailles Project on Advanced Materials and Standards (VAMAS) 50th Steering Committee Meeting CY - London, United Kingdom DA - 15.09.2025 KW - VAMAS KW - Interlaboratory comparison KW - Electron microscopy KW - Lateral size KW - Graphene oxide flakes PY - 2025 UR - https://www.vamas.org/twa41/documents/2023_vamas_twa41_project13_GO_SEM.pdf AN - OPUS4-64228 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Design, characterization, and application of fluorescent sensor particles N2 - pH and oxygen are amongst the most important and frequently measured analytes in the life and material sciences, indicating, e.g., diseases and corrosion processes. This includes the optical monitoring of pH in living cells for studying cellular internalization pathways, such as phagocytosis, endocytosis, and receptor ligand internalization with the aid of molecular and nanoscale fluorescent sensors. Nanoparticle (NP)-based sensors, that are labeled or stained with a multitude of sensor dyes, have several advantages as compare to conventional molecular probes like enhanced brightness, i.e., amplified signals, ease of designing ratiometric systems by combining analyte sensitive and inert reference dyes, and increased photostability. Moreover, this can enable the use of hydrophobic dyes in aqueous environments. Versatile templates and carriers for the fabrication of nanosensors by the staining and/or labelling with different fluorophores and sensor molecules or surface functionalized NP like silica (SiO2-NP) and polystyrene (PS-NP) particles provide. Here we present the design of a versatile platform of color emissive nanosensors and stimuli-responsive microparticles for the measurement of pH, oxygen, and other targets utilizing both types of matrices and sets of spectrally distinguishable sensor and reference dyes and their characterization and demonstrate the applicability of representative sensor particle for cellular studies. T2 - Vortrag bei dem Projekttreffen MicraGen CY - Copenhagen, Denmark DA - 18.08.2022 KW - Dye KW - Luminescence KW - Quantitative spectroscopy KW - Photophysics KW - Quality assurance KW - Nano KW - Particle KW - Quantum yield KW - Lifetime KW - Standard KW - Integrating sphere spectroscopy KW - Sensor KW - pH KW - Oxygen KW - Microfluidics KW - Cancer KW - Cell KW - Life sciences PY - 2022 AN - OPUS4-57049 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Reliable measurements of the photoluminescence quantum yield of transparent and scattering luminophores N2 - Optical measurements of transparent solutions of organic dyes and semiconductor quantum dots and scattering materials such as luminescent nanocomposites and microparticles and phosphors dispersed in liquid and solid matrices play an important role in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. A key performance parameter is the photoluminescence quantum yield QY, i.e., the number of emitted per number of absorbed photons. QY of transparent luminophore solutions can be obtained relative to a fluorescence QY standard of known QY.[1] Meanwhile, a first set of certified fluorescence QY standards is available.[2] Such relative QY measurements require a calibrated spectrofluorometer.[1,3] For determining QY of scattering liquid and solid samples, absolute measurements of QY with a calibrated integrating sphere setup are mandatory.[1,4,5] However, scattering QY standards are not available and uncertainties of such measurements have not yet been assessed in interlaboratory comparisons (ILCs). To determine typical sources of uncertainty of absolute QY measurements, we assessed the influence of the measurement geometry and the optical properties of the blank for determining the number of incident photons absorbed by the sample in an ILC using commercial integrating sphere setups and a custom-designed integrating sphere setup. Samples examined included transparent and scattering dye solutions, solid phosphors such as YAG:Ce optoceramics used as LED converter material, and polymer films stained with different amounts of phosphor microparticles. Matching QY values could be obtained for transparent dye solutions and scattering dispersions with a blank with scattering properties closely matching those of the sample, while QY measurements of optoceramic samples with different blanks revealed substantial differences of more than 20 %. Based on our data, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder as blanks. T2 - eMRS 2025 Fall Meeting CY - Warsaw, Poland DA - 15.09.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Advanced material KW - Synthesis KW - Characterization KW - Fluorescence quantum yield KW - Phosphor KW - Absolute KW - Integrating sphere spectroscopy KW - Dye KW - Standardization KW - Reference material KW - Interlaboratory comparison KW - Uncertainty PY - 2025 AN - OPUS4-64184 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Introduction to Fluorescence Spectroscopy N2 - A brief introduction to fluorescence spectroscopy will be provided, ranging from typically measured fluorescence quantities over instrument-specific contributions to measured fluorescence signals to selected applications. In this context, an overview of the photoluminescence properties of molecular and nanoscale luminescence reporters will be given including a brief insight into their photophysics and fluorescence standards designed by division Biophotonics for the calibration and instrument performance validation of fluorescence measuring devices will be presented. T2 - Analytical Academy CY - Berlin, Germany DA - 13.01.2020 KW - Linearity KW - Fluorescence KW - Dye KW - Quality assurance KW - Nnano particle KW - Method KW - Measurement uncertainty KW - Quantification PY - 2020 AN - OPUS4-51618 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Career Options in Public Service N2 - In the following, an overview of possible career options for chemists is presented covering metrology institutes, departmental research institutes of ministries, Federal and state research institutes and options in areas such as Federal or state institutions in charge of occupational safety, the German armed forces, wastewater treatment plants and labs/institutes controlling water quality, and museums. Thereby also examples and personal insights of the daily work routine are provided for some employers. T2 - Career-Workshop ChiÖD CY - Karlsruhe, Germany DA - 02.04.2025 KW - Quality assurance KW - Reference analysis KW - Standardization KW - Metrology KW - Reference products KW - Reference materials KW - Mission PY - 2025 AN - OPUS4-62867 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - From molecular and nanoscale chromophores with UV/VIS/NIR/SWIR luminescence to multi method characterization of surface coatings N2 - An overview of the research activities of division Biophotonics is presented covering examples for photophysical studies of different types of molecular and nanocrystalline luminophores, luminescent particles, and sensor systems in solution, in dispersion, and in the solid state and multi-method charactreization workflow for the characterization of surface-functionalized engineered nanomaterials. In addition, the importance of reliable optical measurements, particularly standardized workflows for the determination of the key performance parameter luminescence quantum yield of transparent and scattering luminescent samples with fluorescence and integrating sphere spectroscopy, and validated methods for quantifying surface functional groups and ligands on nanomaterials is highlighted. Thereby, also ongoing standardization activities are presented as well as certified reference materials and reference materials from division Biophotonics. T2 - Chinese-German Chemical Association - Annual Meeting CY - Berlin, Germany DA - 22.08.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Quantum yield KW - Characterization KW - Advanced material KW - Surface KW - Lifetime KW - Sensor KW - Oxygen KW - Ph KW - Standardization KW - Fluorescent probe KW - Reference material PY - 2025 AN - OPUS4-64181 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Molecular and nanoscale emitters photophysics , photoluminescence quantum yields, and surface chemistry N2 - Inorganic nanocrystals such as spectrally shifting lanthanide-based nanoparticles (LnNCs) like NaYF4: Yb, Er and semiconductor quantum dots, organic and inorganic particles stained with sensor molecules, and organic dyes showing aggregation-induced emission are meanwhile broadly applied in the life and material sciences. The identification of optimum particle architectures and molecular structures for photonic applications requires quantitative spectroscopic studies and methods to control and analyse particle surface chemistry. In the following, photoluminescence studies of different emitter classes are presented, thereby addressing the measurement of particle brightness and photoluminescence quantum yields in different spectral windows parameters required for an in-depth mechanistic understanding. In addition, examples for the quantification of surface functional groups on nanomaterials with optical spectroscopy are given. T2 - GdCH Kolloquium CY - Düsseldorf, Germany DA - 11.11.2025 KW - Dye KW - Fluorescence KW - Quantum yield KW - Lifetime KW - Sensor materials KW - Temperature KW - Cr(III) complex KW - Nano KW - Particle KW - Silica KW - Polymer KW - Metrology KW - Quality assurance KW - Reference material KW - Surface chemistry KW - Size KW - Shape KW - Particle number concentration KW - Method KW - Optical assay KW - qNMR KW - Validation KW - Potentiometry KW - XPS PY - 2025 AN - OPUS4-64728 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Luminescent Nanoparticles – Photophysics, Mechanistic Studies, and Applications N2 - Inorganic nanocrystals with linear and nonlinear luminescence in the ultraviolet, visible, near infrared and short-wave infrared like semiconductor quantum dots and spectrally shifting lanthanide-based nanophosphors have meanwhile found many applications in the life and material sciences. This includes optical reporters for bioimaging and sensing, security and authentication barcodes, solid state lighting, converter materials, and photovoltaics. The identification of optimum particle structures requires quantitative spectroscopic studies under application-relevant conditions, focusing on the key performance parameter photoluminescence quantum yield, ideally flanked by single particle studies to assess spectroscopic inhomogeneities on a particle-to-particle level for typical preparation methods. In this context, methods to quantify the photoluminescence of these different nanoscale emitters are shown and utilized as a basis for a profound mechanistic understanding of the nonradiative deactivation pathways in semiconductor and upconversion nanocrystals of different size and particle architecture in different environments. Exemplary for the application potential of such nanomaterials, in addition, the design of optical sensors from different nanomaterials and functional organic dyes is briefly summarized. T2 - CRC 1411 Symposium CY - Nürnberg, Germany DA - 20.03.2023 KW - Semiconductor quantum dot KW - Upconversion nanocrystal KW - Luminescence KW - Quantitative spectroscopy KW - Photophysics PY - 2023 AN - OPUS4-57364 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Quantifying functional groups and coatings on nanoobjects N2 - Engineered nanomaterials (NM) of different size, shape, chemical composition, and surface chemistry are increasingly used for many key technologies of the 21st century and consumer products. This includes polymer and silica or silica-coated nanoparticles (NP) with covalently bound surface groups, semiconductor quantum dots (QD), metal and metal oxide NP, and lanthanide NP with coordinatively or electrostatically bound ligands, as well as surface-coated nanostructures like micellar encapsulated NP. Decisive for most applications of NMs are their specific surface properties, which are largely determined by the chemical nature and amounts of ligands and functional groups (FGs) on the NM surface. The surface chemistry can strongly affect the physicochemical properties of NM, their charge, hydrophilicity/hydrophobicity, reactivity, function, stability, and processability and thereby their impact on human health and environment. Knowledge of NM surface chemistry plays an important role for NM functionality and performance in (bio)applications and the fate, exposure, dissolution, transformation, and accumulation of NM, and thus, the potential risks for human health and the environment. This highlights the importance of reliable, validated, and eventually standardized analytical methods for analyzing and quantifying NM surface chemistry for process and quality control of NM production, safe use of NMs, design of novel NM, and sustainable concepts for NM fabrication.[1-3] In this context, interlaboratory comparisons (ILCs) are needed to assess method reliability and reference materials with known surface chemistries for establishing surface analytical methods and their performance validation.[2,4] Also, to respond to the increasing number of samples to be analyzed, cost-efficient automation concepts for surface analysis are needed that can be realized with affordable and preferably commercial instrumentation.[5] Here, we provide an overview of analytical methods for FG analysis and quantification used by us for quantifying broadly utilized FGs and ligands on different types of NMs with electrochemical titration methods, optical assays, nuclear magnetic resonance (NMR) and vibrational (IR) spectroscopy, and X-ray based and thermal analysis methods.[1,2] Thereby, method- and material-related challenges are addressed, and the importance of multi-method characterization approaches easing method validation by method cross-validation. Special emphasis is dedicated to simple, versatile, and cost-efficient methods such as optical assays and electrochemical titration methods. T2 - eMRS Fall Meeting 2025 CY - Warsaw, Poland DA - 15.09.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Characterization KW - Advanced material KW - Surface KW - Standardization KW - Reference material KW - Functional group KW - Quantification KW - Coating KW - Interlaboratory comparison KW - Uncertainty PY - 2025 AN - OPUS4-64183 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Assessing different types of silica networks for the complete protection of nir luminescent molecular rubies from oxygen quenching in air N2 - The application of emerging luminophores such as near-infrared (NIR) emissive earth-abundant chromium(III) (CrIII) complexes and triplet-triplet annihilation upconversion (TTA-UC) systems in air as optical reporters for bioimaging or photonic materials for energy conversion requires simple and efficient strategies for their complete protection from luminescence quenching by oxygen. Therefore, we explored the influence of sol-gel synthesis routes on the oxygen protection efficiency of the resulting core and core/shell silica nanoparticles (SiO2 NPs), utilizing the molecular ruby-type luminophores CrPF6 ([Cr(ddpd)2](PF6)3; ddpd = N,N’-dimethyl- N,N’-dipyridin-2-ylpyridin-2,6-diamine) and CrBF4 ([Cr(ddpd)2](BF4)3) with their oxygen-dependent, but polarity-, proticity-, viscosity-, and concentration-independent luminescence as optical probes for oxygen permeability. The sol-gel chemistry routes we assessed include the classical Stöber method and the underexplored larginine approach, which relies on the controlled hydrolysis of tetraethoxysilane (TEOS) in a biphasic cyclohexane/water system with the catalyst l-arginine. As demonstrated by luminescence measurements of air- and argon-saturated dispersions of CrPF6- and CrBF4-stained SiO2 NPs of different size and particle architecture, utilizing the luminescence decay kinetics of argon-saturated solutions of CrPF6 and CrBF4 in acetonitrile (ACN) as benchmarks, only SiO2 NPs or shells synthesized by the l-arginine approach provided complete oxygen protection of the CrIII complexes under ambient conditions. We ascribe the different oxygen shielding efficiencies of the silica networks explored to differences in density and surface chemistry of the resulting nanomaterials and coatings, leading to different oxygen permeabilities. Our l-arginine based silica encapsulation strategy can open the door for the efficient usage of oxygen-sensitive luminophores and TTA-UC systems as optical reporters and spectral shifters in air in the future. T2 - eMRS Strasbourg CY - Strasbourg, France DA - 26.05.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Quantum yield KW - NIR KW - Mechanism KW - Characterization KW - Electron microscopy KW - Silica KW - Oxygen sensing KW - Surface KW - Doping KW - Lifetime KW - Cr(III) complex PY - 2025 AN - OPUS4-63300 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Getting it right with photoluminescence quantum yields of molecular and nanoscale luminophores and luminescent particles N2 - Photophysical and mechanistic studies, the comparison of different emitter classes, and the rational design of the next generation of molecular and nanoscale reporters require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR. To improve the reliability and comparability of photoluminescence and QY measurements across laboratories, pitfalls, achievable uncertainties, and material-specific effects related to certain emitter classes must be explored. Also, suitable protocols and reference materials are needed which have been validated in interlaboratory comparisons for different wavelength regions and transparent and scattering luminophores.[1] Based on absolute and relative photoluminescence measurements of functional dyes and nanomaterials like semiconductor quantum dots and rods, spectrally shifting lanthanide upconversion nanocrystals, perovskites, and YAG:Cer converter materials, reliable methods for determining QY of transparent and scattering luminophores, nonlinear emitters, and solid luminescent nanomaterials have been developed.[2,3] Thereby, material- and method-related uncertainties of relative and absolute QY measurements and achievable uncertainties could be quantified for linear and nonlinear UV/vis/NIR/SWIR emitters and lately for also luminescent and scattering materials and solid phoshors, here in an interlaboratory comparison of three labs utilizing integrating sphere spectroscopy.[4,5] In addition, to provide simple tools for a better comparability of QY measurements, recently, a first set of UV/vis/NIR quantum yield standards has been developed and certified with complete uncertainty budgets.[6] In the following, the outcome of these studies will be presented, thereby addressing common pitfalls and providing recommendations on the performance of reliable QY measurements of linear and non-linear emitters in transparent, scattering, and solid samples. T2 - 29th Lecture Conference on Photochemistry (LCP 2024) GDCh CY - Mainz, Germany DA - 16.09.2024 KW - Nanoparticle KW - Nano KW - Luminescence KW - Quality assurance KW - Synthesis KW - Standardization KW - Reference material KW - Quantum yield KW - Fluorescence KW - Reference data KW - Integrating sphere spectroscopy KW - ILC KW - Converter material KW - YAG:Ce KW - Optoceramic PY - 2024 AN - OPUS4-61075 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Quantifying the total and accessible amount of surface functionalities and ligands on nanomaterials N2 - Engineered nanomaterials (NMs) of various chemical composition and surface functionalization are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage. NM dispersibility, stability, processability, and function as well as the interaction with biological species and environmental fate are largely determined by NM surface functionalities, i.e., functional groups (FGs) and ligands. Therefore, reliable, reproducible, and eventually standardized surface characterization methods are vital for quality control of NMs, and mandatory to meet increasing concerns regarding their safety. Suitable methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques such as traceable quantitative nuclear magnetic resonance (qNMR) as well as X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods.[1] The latter less costly and fast methods, which can be automated, are often used by NM producers for process and quality control.[1,2] To validate methods, establish measurement uncertain-ties, test reference materials, and produce reference data, multi-method characterization studies are needed.[3,4] as well as interlaboratory comparisons (ILC) on determining NM surface chemistry and well characterized test and reference NMs providing benchmark values.[5,6] Here, we present examples for quantifying common surface FGs such as amino and carboxyl groups on functional NMs of different chemical composition such as silica, polymer, iron oxide, and lanthanide-based upconversion nanoparticles with optical assays, electrochemical titration methods, qNMR, and chromatographic separation techniques. In addition, ongoing interlaboratory comparisons will be presented. T2 - Yucomat 2025 CY - Herec Novi, Montenegro DA - 01.09.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Characterization KW - Advanced material KW - Surface KW - Standardization KW - Reference material KW - Functional group KW - Quantification KW - Coating KW - Interlaboratory comparison KW - Uncertainty PY - 2025 AN - OPUS4-64182 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Forschung in einer Bundesoberbehörde wie der BAM N2 - Die Bundesanstalt für Materialforschung und -prüfung (BAM) ist eine forschende Bundesoberbehörde und Einrichtung der Ressortforschung der Bundesrepublik Deutschland. Unter ihrer Leitlinie „Sicherheit in Technik und Chemie“ ist sie zuständig für die öffentliche technische Sicherheit und für metrologische Aufgaben in der Chemie. Das Aufgabenspektrum der BAM, das sich an aktuellen Fragestellungen aus Wissenschaft, Wirtschaft, Politik und Normung orientiert, bietet sehr viele interessante Tätigkeitsfelder für Naturwissenschaftler*Innen und Ingenieur*Innen. T2 - WIFO Leipzig 2023 CY - Leipzig, Germany DA - 05.09.2023 KW - Quality assurance KW - Optical spectroscopy KW - Certification KW - Reference product KW - Integrating sphere spectroscopy KW - Fluorescence KW - Quantum yield KW - Reference material KW - Reference data KW - Traceability KW - Nano KW - Particle KW - Analytical chemistry KW - Sensor KW - Safety PY - 2023 AN - OPUS4-58397 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Engineered Nanomaterials- Novel Approaches for Risk Assessment and Safe-by-Design N2 - The overall interest in nanotoxicity, triggered by the increasing use of nanomaterials in the material and life sciences, and the synthesis of an ever increasing number of new functional nanoparticles calls not only for standardized test procedures1,2 and for efficient approaches to screen the potential genotoxicity of these materials, but also for standardized and validated methods for surface analysis. 4,5 The analysis and quantification of surface chemistry is hence in the focus of an increasing number of standardization organizations and interlaboratory comparisons with different analytical methods are being done.5 For the monitoring of nanomaterial synthesis and the fast assessment of the number of functional groups such as carboxyl and amino functionalities, which are very commonly used functionalities in the life sciences, simple and validated methods are needed that can be performed with common laboratory instrumentation. 5,6 Here we provide a brief overview of the ongoing research in division Biophotonics employing quantitative NMR (qNMR), conductometry, and colorimetric and fluorometric optical assays for the determination of the total and the accessible number of carboxyl and amino groups on differently sized polymer and silica nano- and microparticles.5-7 T2 - Workshop NanoRiskSD project CY - Berlin, Germany DA - 09.06.2022 KW - Nanoparticle KW - Surface analysis KW - Standardization KW - Quality assurance KW - Validation KW - qNMR KW - Silica KW - Polymer KW - Fluorescence KW - Assay KW - Conductometry KW - Method comparison KW - Analytical sciences PY - 2022 AN - OPUS4-54999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Applications of photoluminescence lifetime measurements in the life and material sciences N2 - Bioanalytical, diagnostic, and security applications require the fast and sensitive determination of a steadily increasing number of analytes or events in parallel in a broad variety of detection formats and increased sensitivities. This – flanked by recent technical advancements and the availability of simple to use, commercial time-resolved photoluminescence measuring devices at reasonable costs - calls for the exploitation of the species- and environment-specific photoluminescence parameter luminescence lifetime. In this context, time-resolved photoluminescence measurements of different classes of molecular and nanocrystalline emitter and luminescent particles in different time windows are presented and examples for applications such as lifetime multiplexing and barcoding in conjunction with fluorescence lifetime imaging microscopy (FLIM) and flow cytometry are given. T2 - Eingeladener Vortrag bei dem Workshop von Picoquant „Time-resolved fluorescence“ CY - Berlin, Germany DA - 17.11.2022 KW - Dye KW - Quantum dot KW - Upconversion nanocrystal KW - Luminescence KW - Quantitative spectroscopy KW - Photophysics KW - Quality assurance KW - Nano KW - Particle KW - Quantum yield KW - Lifetime KW - Standard KW - Reference material PY - 2022 AN - OPUS4-57048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Design and Quantitative Characterization of Functional Molecular Chromophores and Nanomaterials with UV/vis/NIR/IR Emission – An Overview of Research Activities in Division Biophotonics N2 - In the focus of division Biophotonics are the design, preparation, analytical and spectroscopic characterization, and application of molecular and nanoscale functional materials, particularly materials with a photoluminescence in the visible, near infrared (NIR) and short-wave infrared (SWIR). This includes optical reporters for bioimaging and sensing, security and authentication barcodes, and materials for solid state lighting, energy conversion, and photovoltaics. For the identification of optimum particle structures quantitative spectroscopic studies are performed under application-relevant conditions, focusing on the key performance parameter photoluminescence quantum yield. In addition, simple, cost-efficient, and standardizable strategies for quantifying functional groups on the surface of nano- and microparticles are developed, here with a focus on optical assays and electrochemical titration methods, cross-validated by more advanced methods such as quantitative NMR. In addition, reference materials and reference products are developed for optical methods, particularly luminescence techniques, and for analytical methods utilized for the characterization of nanomaterials. T2 - Projekttreffen Nile-Chrome 2.0 CY - Mainz, Germany DA - 11.12.2023 KW - Fluorescence KW - Quantum yield KW - Optical spectroscopy KW - Reference material KW - Reference data KW - Quality assurance KW - Dye KW - Reference product KW - NIR KW - SWIR KW - Nano KW - Particle KW - Silica KW - Polymer KW - Surface group analysis KW - Sensor molecules PY - 2023 AN - OPUS4-59123 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Measuring the Upconversion Luminescence of Ensemble and Single Particle Lanthanide-Based Upconversion Nanocrystals N2 - Lanthanide-based upconversion nanoparticles (UCNPs) like hexagonal 𝛽-NaYF4 UCNPs doped with Yb3+ and Er3+, which efficiently convert 976 nm light to ultraviolet, visible, and near infrared photons, offer new strategies for luminescence-based sensing, barcoding, and Imaging. Their upconversion (UC) luminescence (UCL) features like UCL intensity, quantum yield, relative spectral distribution / UCL luminescence color, and luminescence decay kinetics are, however, strongly influenced by particle size, dopant ion concentration, particle architecture, surface chemistry including presence and thickness of surface passivation and shielding shells, microenvironment/presence of quenchers with high energy vibrations, and excitation power density (P). We present here a comprehensive study of the influence of excitation power density on the UCL features of different types of UCNPs, focusing on Yb3+ and Er3+ co-doped NaYF4 core-only and core-shell nanostructures with different sizes and doping ion concentration, which underlines the importance of P-dependent optimum dopant concentrations for UCNP performance and the potential of P-tuning of UCL. T2 - Materials Challenges in Alternative & Renewable Energy 2021 (MCARE 2021) CY - Online meeting DA - 19.07.2021 KW - Fluorescence KW - Lifetime KW - Method KW - Stability KW - Coating KW - Surface chemistry KW - Lanthanide KW - Upconversion KW - Nano KW - Particle KW - Single particle spectroscopy KW - Quantum yield KW - Microscopy KW - Photophysics PY - 2021 AN - OPUS4-53111 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Typical Measurements in Optical Spectroscopy – Absorption Spectroscopy or Photometry N2 - The basics of absorption spectroscopy (termed also photometry) will be presented with focus on transparent solutions of different molecular and nanocrystalline absorbers and the ultraviolet (UV), visible (vis), and near-infrared (NIR) spectral region. Thereby, also typical sources of uncertainty will be addressed. Subsequently, several examples for typical applications of absorption measurements in the life and material sciences will be briefly shown ranging from aggregation studies and dye labeling densities of biomolecules (dye-to-biomolecule ratios) over optical assays for thiol and protein quantification to the optical determination of the size of semiconductor nanocrystals using size curves. T2 - pHD Seminar CY - Online meeting DA - 03.11.2020 KW - Quantification KW - Absorption KW - Dye KW - Nano particle KW - Method KW - Measurement uncertainty KW - Linearity PY - 2020 AN - OPUS4-51621 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Introduction to Fluorescence Spectroscopy N2 - A brief introduction to fluorescence spectroscopy will be provided, ranging from typically measured fluorescence quantities over instrument-specific contributions to measured fluorescence signals to selected applications. In this context, an overview of the photoluminescence properties of molecular and nanoscale luminescence reporters will be given including a brief insight into their photophysics and fluorescence standards designed by division Biophotonics for the calibration and instrument performance validation of fluorescence measuring devices will be presented. T2 - Analytical Academy BAM CY - Online meeting DA - 17.11.2020 KW - Fluorescence KW - Quality assurance KW - Quantification KW - Linearity KW - Measurement uncertainty KW - Method KW - Nano particle KW - Dye PY - 2020 AN - OPUS4-51619 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Design and Quantitative Characterization of Functional Molecular Chromophores and Nanomaterials with UV/vis/NIR/IR Emission and Traceable Optical Measurements N2 - Research of division Biophotonics at the Federal Institute for Materials Research and Testing (BAM) covers several topics including photophysics of molecular and nanocrystalline emitters, the development of signal enhancement, multiplexing, and barcoding strategies, surface group quantification, the rational design of different types of stimuli-responsive optical probes, and concepts and reference materials for the validation of optical-spectroscopic measurements. In the following representative examples for each of these topics are given. Also, current developments like single particle spectroscopy and flow cytometry with lifetime detection and newly certified fluorescence quantum yield standards are presented. T2 - Kolloquium BfR CY - Berlin, Germany DA - 12.10.2020 KW - Fluorescence KW - Quantitative spectroscopy KW - Single particle spectroscopy KW - Multiplexing KW - Reference materials KW - Optical probes KW - Sensor molecules KW - Assay KW - Dye KW - Quantum yield KW - Method development KW - surface group analysis KW - synthesis KW - fluorescence standards PY - 2020 AN - OPUS4-51449 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Functional Luminophores – From Photophysics to Standardized Luminescence Measurements N2 - Inorganic nanocrystals with linear and nonlinear luminescence in the ultraviolet, visible, near infrared and short-wave infrared like semiconductor quantum dots and spectrally shifting lanthanide-based nanophosphors have meanwhile found applications in the life and material sciences ranging from optical reporters for bioimaging and sensing over security barcodes to solid state lighting and photovoltaics. These nanomaterials commonly have increasingly sophisticated core/shell particle architectures with shells of different chemical composition and thickness to minimize radiationless deactivation at the particle surface that is usually the main energy loss mechanism [1]. For lanthanide-based spectral shifters, particularly for very small nanoparticles, also surface coatings are needed which protect near-surface lanthanide ions from luminescence quenching by high energy vibrators like O-H groups and prevent the disintegration of these nanoparticles under high dilution conditions. [2,3,4]. The identification of optimum particle structures requires quantitative spectroscopic studies focusing on the key performance parameter photoluminescence quantum yield [5,6], ideally flanked by single particle studies to assess spectroscopic inhomogeneities on a particle-to-particle level for typical preparation methods [7,8], Moreover, in the case of upconversion nanoparticles with a multi-photonic and hence, excitation power density (P)-dependent luminescence, quantitative luminescence studies over a broad P range are required to identify particle architectures that are best suited for applications in fluorescence assays up to fluorescence microscopy. Here, we present methods to quantify the photoluminescence of these different types of emitters in the vis/NIR/SWIR and as function of P and demonstrate the importance of such measurements for a profound mechanistic understanding of the nonradiative deactivation pathways in semiconductor and upconversion nanocrystals of different size and particle architecture in different environments. T2 - Eingeladener Vortrag Uni Erlangen CY - Erlangen, Germany DA - 18.01.2023 KW - Semiconductor quantum dot KW - Upconversion nanocrystal KW - Luminescence KW - Quantitative spectroscopy KW - Photophysics KW - Quality assurance KW - Nano KW - Particle KW - Quantum yield KW - Lifetime KW - Standard KW - Reference material KW - Surface analysis KW - Quantification PY - 2023 AN - OPUS4-57011 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - A journey in science from a graduate student in physical chemistry to head of division biophotonics N2 - I will provide a personal overview of the most important steps of my career in science, a journey from a graduate student in physical chemistry in an environment dominated by male-scientists over a postdoc with a female professor in the US to the leader of a research group, head of division Biophotonics at BAM. This will include my choices of research topics, how I learnt to write well cited publications, even on topics such as reference materials and quality assurance,1-4 and eventually started to give lectures at Free University Berlin granting me the right to act as first supervisor of undergraduate and graduate students. T2 - Women in Science CY - Erlangen, Germany DA - 22.07.2024 KW - Lanthanide KW - Nanoparticle KW - Silica KW - Quantum dot KW - Polymer KW - Surface group KW - Luminescence KW - Quantitative spectroscopy KW - Quantum yield KW - Lifetime KW - Quality assurance KW - Synthesis KW - Surface modification KW - Photophysics PY - 2024 AN - OPUS4-60724 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Functional molecular chromophores and nanomaterials reporters, optical probes, and sensors N2 - •Overview of expertise of division Biophotonics •Functional molecular and nanoscale luminescent reporters, probes, and sensors including design principles available from division Biophotonics •Examples for pH and O2 responsive molecular probes and particle sensors •Surface group quantification Analytical methods and cleavable probes •Concepts & standards for the validation and traceability of optical measurements T2 - FU-Seminar CY - Berlin, Germany DA - 09.12.2022 KW - Particle sensors KW - Surface group quantification KW - Nanoscale luminescent reporters KW - Cleavable probes PY - 2022 AN - OPUS4-56526 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Photoluminescence quantum yields of molecular & nanoscale luminophores in the UV/VIS/NIR/SWIR in dispersion and in the solid state N2 - Photophysical and mechanistic studies, the comparison of different emitter classes, and the rational design of the next generation of molecular and nanoscale reporters require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR. T2 - MAF 2024 Conference CY - Valencia, Spain DA - 08.09.2024 KW - Nanoparticle KW - Nano KW - Luminescence KW - Quality assurance KW - Synthesis KW - Standardization KW - Reference material KW - Quantum yield KW - Fluorescence KW - Reference data KW - Integrating sphere spectroscopy KW - ILC KW - Converter material PY - 2024 AN - OPUS4-61072 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Absolute Determination of Photoluminescence Quantum Yields of Scattering LED Converter Materials – How to Get it Right N2 - Optical measurements of scattering luminescent materials dispersed in liquid and solid matrices and luminescent powders play an important role in fundamental research and industry. Typical examples are luminescent nano- and microparticles and phosphors of different composition in different matrices or incorporated into ceramics with applications in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. The key parameter for the performance of these materials is the photoluminescence quantum yield QY, i.e., the number of emitted photons per number of absorbed photons. QY of transparent luminophore solutions can be determined relatively to a fluorescence quantum yield standard of known QY. Such standards are meanwhile available as certified reference materials.[1] The determination of QY of scattering liquid and solid samples like dispersions of luminescent nanoparticles, solid phosphors, and optoceramics requires, however, absolute measurements with an integrating sphere setup. Although the importance of reliable absolute QY measurements has been recognized, no interlaboratory comparisons (ILCs) on measurement uncertainties and the identification of typical sources of uncertainty have been yet reported. Also, no scattering reference materials with known QY are available. We present here the results of a first ILC of 3 laboratories from academia and industry performed to identify and quantify sources of uncertainty of absolute QY measurements of scattering samples. Thereby, two types of commercial stand-alone integrating sphere setups with different illumination and detection geometries were utilized for measuring QY of transparent and scattering dye solutions and solid phosphors. As representative and industrially relevant solid and scattering samples, YAG:Ce optoceramics of varying surface roughness were chosen, applied, e.g., as converter materials for blue light emitting diodes. Special emphasis was dedicated to the influence of the measurement geometry, the optical properties of the blank, utilized to determine the number of photons of the incident excitation light absorbed by the sample, and the sample-specific surface roughness. While matching QY values could be obtained for transparent dye solutions and scattering dispersions, here using a blank with scattering properties closely matching those of the sample, QY measurements of optoceramic samples with different blanks revealed substantial differences, with the blank's optical properties accounting for measurement uncertainties of more than 20 %. Based upon the ILC results, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder which reveals a near-Lambertian light scattering behavior, yielding a homogeneous light distribution within the integrating sphere. T2 - e-MRS 2024 CY - Strasbourg, France DA - 27.05.2024 KW - Luminescence KW - Quantitative spectroscopy KW - Nano KW - Particle KW - Quantum yield KW - Lifetime KW - Quality assurance KW - Phosphor KW - Converter marterial KW - Fluorescence KW - Interlaboratory KW - Comparison KW - Method KW - Uncertainty KW - Reference material PY - 2024 AN - OPUS4-60490 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -