TY - GEN A1 - Pauw, Brian Richard A1 - Szymoniak, Paulina T1 - Dataset and Jupyter worksheet interpreting the (results from) small- and wide-angle scattering data from a series of boehmite/epoxy nanocomposites. Accompanies the publication "Competition of nanoparticle-induced mobilization and immobilization effects on segmental dynamics of an epoxy-based nanocomposite" N2 - Dataset and Jupyter worksheet interpreting the (results from) small- and wide-angle scattering data from a series of boehmite/epoxy nanocomposites. Accompanies the publication "Competition of nanoparticle-induced mobilization and immobilization effects on segmental dynamics of an epoxy-based nanocomposite", by Paulina Szymoniak, Brian R. Pauw, Xintong Qu, and Andreas Schönhals. Datasets are in three-column ascii (processed and azimuthally averaged data) from a Xenocs NanoInXider SW instrument. Monte-Carlo analyses were performed using McSAS 1.3.1, other analyses are in the Python 3.7 worksheet. Graphics and result tables are output by the worksheet. KW - Small angle scattering KW - X-ray scattering KW - Nanocomposite KW - Polymer nanocomposite KW - Boehmite KW - Analysis KW - SAXS/WAXS PY - 2020 DO - https://doi.org/10.5281/zenodo.4321087 PB - Zenodo CY - Geneva AN - OPUS4-51829 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Deumer, J. A1 - Pauw, Brian Richard A1 - Marguet, S. A1 - Skroblin, D. A1 - Taché, O. A1 - Krumrey, M. A1 - Gollwitzer, C. T1 - Small-angle X-ray scattering: characterization of cubic Au nanoparticles using Debye’s scattering formula N2 - A versatile software package in the form of a Python extension, named CDEF (computing Debye’s scattering formula for extraordinary form factors), is proposed to calculate approximate scattering profiles of arbitrarily shaped nanoparticles for small-angle X-ray scattering (SAXS). CDEF generates a quasi-randomly distributed point cloud in the desired particle shape and then applies the open-source software DEBYER for efficient evaluation of Debye’s scattering formula to calculate the SAXS pattern (https://github.com/j-from-b/CDEF). If self-correlation of the scattering signal is not omitted, the quasi-random distribution provides faster convergence compared with a true-random distribution of the scatterers, especially at higher momentum transfer. The usage of the software is demonstrated for the evaluation of scattering data of Au nanocubes with rounded edges, which were measured at the four-crystal monochromator beamline of PTB at the synchrotron radiation facility BESSY II in Berlin. The implementation is fast enough to run on a single desktop computer and perform model fits within minutes. The accuracy of the method was analyzed by comparison with analytically known form factors and verified with another implementation, the SPONGE, based on a similar principle with fewer approximations. Additionally, the SPONGE coupled to McSAS3 allows one to retrieve information on the uncertainty of the size distribution using a Monte Carlo uncertainty estimation algorithm. KW - X-ray scattering KW - SAXS KW - Non-spherical nanoparticles KW - Nanoparticles KW - Nanomaterials KW - Debye scattering equation KW - Simulation KW - Data fitting PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-557652 DO - https://doi.org/10.1107/S160057672200499X VL - 55 IS - Pt 4 SP - 993 EP - 1001 PB - International Union of Crystallography CY - Chester, England AN - OPUS4-55765 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Marc Benjamin T1 - Accessing radiation damage to biomolecules on the nanoscale by particle-scattering simulations N2 - Radiation damage to DNA plays a central role in radiation therapy to cure cancer. The physico-chemical and biological processes involved encompass huge time and spatial scales. To obtain a comprehensive understanding on the nano and the macro scale is a very challenging tasks for experimental techniques alone. Therefore particle-scattering simulations are often applied to complement measurements and aide their interpretation, to help in the planning of experiments, to predict their outcome and to test damage models. In the last years, powerful multipurpose particle-scattering framework based on the Monte-Carlo simulation (MCS) method, such as Geant4 and Geant4-DNA, were extended by user friendly interfaces such as TOPAS and TOPAS-nBio. This shifts their applicability from the realm of dedicated specialists to a broader range of scientists. In the present review we aim to give an overview over MCS based approaches to understand radiation interaction on a broad scale, ranging from cancerous tissue, cells and their organelles including the nucleus, mitochondria and membranes, over radiosensitizer such as metallic nanoparticles, and water with additional radical scavenger, down to isolated biomolecules in the form of DNA, RNA, proteins and DNA-protein complexes. Hereby the degradation of biomolecules by direct damage from inelastic scattering processes during the physical stage, and the indirect damage caused by radicals during the chemical stage as well as some parts of the early biological response is covered. Due to their high abundance the action of hydroxyl radicals (•OH) and secondary low energy electrons (LEE) as well as prehydrated electrons are covered in additional detail. Applications in the prediction of DNA damage, DNA repair processes, cell survival and apoptosis, influence of radiosensitizer on the dose distribution within cells and their organelles, the study of linear energy transfer (LET), the relative biological effectiveness (RBE), ion beam cancer therapy, microbeam radiation therapy (MRT), the FLASH effect, and the radiation induced bystander effect are reviewed. KW - DNA KW - Protein KW - G5P KW - OH KW - Au KW - AuNP KW - Radiation KW - SSB KW - DSB KW - Beta decay KW - Brachytherapy KW - Cancer treatment KW - Clustered nanoparticles KW - DNA damage KW - Dosimetry KW - Energy deposit KW - Geant4 KW - Geant4-DNA KW - Gold Nanoparticles KW - Livermore model KW - Low energy electrons KW - MCS KW - Microdosimetry KW - Monte-Carlo simulation KW - NP KW - OH radical KW - Particle scattering KW - Penelope model KW - Proteins KW - Radiation damage KW - Radiation therapy KW - Radiationtherapy KW - Radioactive decay KW - Radiolysis KW - Radiotherapy KW - Simulation KW - TOPAS KW - TOPAS-nbio KW - Base damage KW - Base loss KW - DNA radiation damage KW - Direct damage KW - Dissociative electron attachment (DEA) KW - Dissociative electron transfer (DET) KW - Double-strand break (DSB) KW - ESCA KW - Hydrated DNA KW - Hydrated electron KW - Hydration shell KW - Hydroxyl radical KW - Indirect damage KW - Ionization KW - Ionisation KW - NAP-XPS KW - Near ambient pressure xray photo electron spectroscopy KW - Net-ionization reaction KW - Prehydrated electron KW - Presolvated electron KW - Quasi-direct damage KW - ROS KW - Radical KW - Reactive oxygen species KW - Single-strand break (SSB) KW - XPS KW - Xray KW - Xray photo electron spectrocopy KW - Cosolute KW - Ectoin KW - Ectoine KW - GVP KW - Gene five protein KW - Hydroxyectoine KW - Ionizing radiation damage KW - OH radical scavenger KW - Monte-Carlo simulations KW - Nanodosimetry KW - Osmolyte KW - Particle scattering simulations KW - Protein unfolding KW - Radical Scavenge KW - Radical scavenger KW - Single-stranded DNA-binding proteins KW - SAXS KW - Bio-SAXS KW - X-ray scattering KW - ssDNA KW - dsDNA KW - FLASH effect KW - Bystander effect KW - Ion beam therapy KW - Bragg peak KW - LET KW - MCNP KW - Photons KW - Electrons KW - Carbon ions KW - MRT KW - RNA KW - RBE KW - base loss KW - abasic side KW - DMSO KW - Cells PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-573240 DO - https://doi.org/10.1088/2399-6528/accb3f SN - 2399-6528 VL - 7 IS - 4 SP - 042001 PB - Institute of Physics (IOP) Publishing CY - London AN - OPUS4-57324 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krauss, S. W. A1 - Eckardt, M. A1 - Will, J. A1 - Spiecker, E. A1 - Siegel, R. A1 - Dulle, M. A1 - Schweins, R. A1 - Pauw, Brian Richard A1 - Senker, J. A1 - Zobel, M. T1 - H-D-isotope effect of heavy water affecting ligand-mediated nanoparticle formation in SANS and NMR experiments N2 - An isotopic effect of normal (H2O) vs. heavy water (D2O) is well known to fundamentally affect structure and chemical properties of proteins, for instance. Here we correlate results from small angle X-ray and neutron scattering (SAXS, SANS) with high-resolution scanning transmission electron microscopy to track the evolution of CdS nanoparticle size and crystallinity from aqeuous solution in presence of the organic ligand ethylenediaminetetraacetate (EDTA) at room temperature in both H2O and D2O. We provide evidence via SANS experiments that exchanging H2O by D2O impacts nanoparticle formation by changing the equilibria and dynamics of EDTA clusters in solution as investigated by nuclear magnetic resonance. The colloidal stability of the CdS nanoparticles, covered by a layer of [Cd(EDTA)]2- complexes, is significantly reduced in D2O despite the strong stabilizing effect of EDTA in suspensions of normal water. Hence, conclusions about nanoparticle formation mechanisms from D2O solutions can bare limited transferability to reactions in normal water due to isotopic effects, which thus need to be discussed for contrast match experiments. KW - General Materials Science KW - Quantum dots KW - CdS KW - Deuterium KW - X-ray scattering KW - MOUSE PY - 2023 DO - https://doi.org/10.1039/D3NR02419A SN - 2040-3364 VL - 15 IS - 40 SP - 16413 EP - 16424 PB - Royal Society of Chemistry (RSC) AN - OPUS4-58294 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Everything SAXS Part 1: Introduction, Sample Requirements and Measurement "Space" N2 - This talk for the Swiss Society for Crystallography (SSCr) workshop on SAXS will introduce scattering from various angles, focusing in particular on: - Information content of X-ray scattering experiments, three entry points… - An introduction to Fourier Transforms - Sample criteria, compatibility, and selection - Key indicators of a measurement – where is the information? - Key indicators of measurement quality - Experiment planning, the basics T2 - Topical workshop of the Swiss Society for Crystallography CY - Zurich, Switzerland DA - 08.09.2023 KW - X-ray scattering KW - Data stewardship KW - Measurement science KW - MOUSE KW - Holistic experiment approaches PY - 2023 AN - OPUS4-58235 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Everything SAXS Part 2: Data Processing, Workflow and Pitfalls N2 - The second talk for the Swiss Society for Crystallography (SSCr) workshop on SAXS will highlight the data processing challenges, holistic experimental workflow developments, and the pitfalls. In particular, the following items will be addressed: - The importance of data processing and estimating uncertainty - A universal correction pipeline – away with the headaches, at least for this step! - Experiment planning part 2, some tips and advice to improve your corrected data. - Sample preparation, background selection, some tips and advice to improve your corrected data. - Automate for your mental well-being; electronic logbooks, measurement catalogs and workflow management software - Life on the edge: several pitfalls to avoid… T2 - Topical workshop of the Swiss Society for Crystallography CY - Zurich, Switzerland DA - 08.09.2023 KW - X-ray scattering KW - MOUSE KW - Data processing KW - Uncertainties KW - Pitfalls PY - 2023 AN - OPUS4-58236 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tache, O. T1 - Synthesis of SiO2 Nanoparticles as reference materials: Metrological measurements and in-situ kinetics in lab with Small Angle X-Ray Scattering N2 - The unambiguous correlation of possible health and sustainability risks to nanoparticle size must be enabled by reliable measurement of nanoparticle size, to ensure comparability and compatibility between results measured under different methods. The NPSIZE project funded by European Metrology Program (EMPIR) develop methods, reference materials and modelling to improve the traceability chain, comparability and compatibility of nanoparticle size measurements. In this work, we present how spherical silica nanoparticles are synthetized with controlled monomodal or bimodal dispersion to be use as reference materials and international round-robin. Improving the fabrication requires a fine understanding of synthesis (1), coupled with an expertise of in-situ or ex-situ analysis methods. This is a new challenge for the analysis : determining not only average characteristics (size, chemical composition and shape ...) but also the concentration and the distribution over the population studied (2). Small-Angle X-ray Scattering (3) allows very precise measurements of the nanoparticles size and concentration that can be directly link to the metric system (4) (metrological traceability) . We developed a SAXS laboratory instrument dedicated to the in-situ characterization of nanoparticles, which enable fast measurements, and the monitoring of the synthesis parameters. Measurement protocols and software processing chain (5) (i.e. size distribution) are also combined & optimized. T2 - CNANO2021 CY - Toulouse, France DA - 25.11.2021 KW - X-ray scattering KW - Silica particles KW - Synthesis KW - Reference materials PY - 2021 DO - https://doi.org/10.5281/zenodo.5749256 AN - OPUS4-53931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Szymoniak, Paulina T1 - Spatial Inhomogeneity, Interfaces and Complex Vitrification Behavior of Epoxy-based Materials N2 - This work deals with an in-depth comparative investigation of the structure, molecular mobility and vitrification kinetics of three bisphenol A diglycidyl ether (DGEBA)-based materials with different nanofillers: taurine-modified layered double hydroxide (T-LDH) and halloysite nanotubes (HNTs). The chosen methodology comprises I) small – and wide – angle X-ray scattering (SAXS/WAXS) II) calorimetry in the forms of a) conventional DSC and b) static fast scanning calorimetry (FSC), III) broadband dielectric spectroscopy (BDS), as well as IV) specific heat spectroscopy in the forms of a) temperature modulated DSC, and b) temperature modulated FSC. T2 - Abteilungsseminar 6. - FB 6.6 CY - Online meeting DA - 06.05.2021 KW - Broadband dielectric spectroscopy KW - Epoxy nanocomposites KW - Halloysite nanotubes KW - X-ray scattering KW - Differential scanning calorimetry KW - Rigid amorphous fraction KW - Flash DSC PY - 2021 AN - OPUS4-52697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Li, Z. A1 - Raab, A. A1 - Kolmangadi, Mohamed Aejaz A1 - Busch, M. A1 - Grunwald, M. A1 - Demel, F. A1 - Bertram, F. A1 - Kityk, A. V. A1 - Schönhals, Andreas A1 - Laschat, S. A1 - Huber, P. T1 - Self-Assembly of Ionic Superdiscs in Nanopores N2 - Discotic ionic liquid crystals (DILCs) consist of self-assembled superdiscs of cations and anions that spontaneously stack in linear columns with high one-dimensional ionic and electronic charge mobility, making them prominent model systems for functional soft matter. Compared to classical nonionic discotic liquid crystals, many liquid crystalline structures with a combination of electronic and ionic conductivity have been reported, which are of interest for separation membranes, artificial ion/proton conducting membranes, and optoelectronics. Unfortunately, a homogeneous alignment of the DILCs on the macroscale is often not achievable, which significantly limits the applicability of DILCs. Infiltration into nanoporous solid scaffolds can, in principle, overcome this drawback. However, due to the experimental challenges to scrutinize liquid crystalline order in extreme spatial confinement, little is known about the structures of DILCs in nanopores. Here, we present temperaturedependent high-resolution optical birefringence measurement and 3D reciprocal space mapping based on synchrotron X-ray scattering to investigate the thermotropic phase behavior of dopamine-based ionic liquid crystals confined in cylindrical channels of 180 nm diameter in macroscopic anodic aluminum oxide membranes. As a function of the membranes’ hydrophilicity and thus the molecular anchoring to the pore walls (edge-on or face-on) and the variation of the hydrophilic−hydrophobic balance between the aromatic cores and the alkyl side chain motifs of the superdiscs by tailored chemical synthesis, we find a particularly rich phase behavior, which is not present in the bulk state. It is governed by a complex interplay of liquid crystalline elastic energies (bending and splay deformations), polar interactions, and pure geometric confinement and includes textural transitions between radial and axial alignment of the columns with respect to the long nanochannel axis. Furthermore, confinement-induced continuous order formation is observed in contrast to discontinuous first-order phase transitions, which can be quantitatively described by Landau-de Gennes free energy models for liquid crystalline order transitions in confinement. Our observations suggest that the infiltration of DILCs into nanoporous solids allows tailoring their nanoscale texture and ion channel formation and thus their electrical and optical functionalities over an even wider range than in the bulk state in a homogeneous manner on the centimeter scale as controlled by the monolithic nanoporous scaffolds. KW - Ionic Liquid Crystals KW - Nanopropous materials KW - Landau de-Gennes analysis KW - X-ray scattering KW - Optical birefringence PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-600797 DO - https://doi.org/10.1021/acsnano.4c01062 SN - 1936-0851 VL - 18 IS - 22 SP - 14414 EP - 14426 PB - ACS AN - OPUS4-60079 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seilert, J. T1 - (Re)engineering functional fat phases – bridging industry and ivory tower N2 - The crystallization kinetics of commercial structuring fats are determined by the interplay of polymorphic transitions and the formation of mixed crystals involving three primary melting groups: H3, H2M, and H2U. Here, H represents long-chain saturated fatty acids, M denotes medium-chain saturated fatty acids, and U signifies unsaturated fatty acids. Assigning the molecular makeup of structuring fats to the kinetic pathways proves to be a challenging task when dealing with complex mixtures. For example, incorporating H2M triglycerides alters the crystallization pathways substantially by impacting the formation of mixed crystals with and between H3 and H2U triglycerides (TAGs). However, determining the impact of specifics in molecular composition, e.g., fatty acid content and TAG asymmetry, remains a complex challenge when dealing with intricate mixtures. This might be overcome by targeting distinct melting groups and comparing their behavior in complex mixtures to academic replicates. This study examined four commercial blends with different fatty acids (palmitic versus stearic acid) and varying H3 contents (8% versus 4%), C8-P, C8-S, C4-P, and C4-S. The H2M content and sum of structuring melting groups was kept constant at 9 % and 25 %, respectively. Further, the commercial blends were replicated using synthetic triglycerides representing the main melting groups: PPP and SSS for H3, PLaP and SLaS for H2M and POP and SOS for H2U – resulting in academic blends A8-P, A8-S, A4-P, and A4-S. The crystallization under quiescent conditions at a cooling rate of 3.5 K/min of all eight blends was studied via DSC and time-resolved SAXS/WAXS. While the P-based commercial blends (C8-P and C4-P) followed typical crystallization routes including an α-β’ transition and clear dependency on H3 content, the S-based counterparts, C8-S and C4-S, showed an α-phase of prolonged stability and evidence of two distinct β’ phases. Differences between commercial and academic blends are discussed. T2 - 2nd Berlin Symposium on Structured Lipid Phases CY - Berlin, Germany DA - 30.09.2024 KW - Lipid phases KW - Thermal structuring KW - Crystallography KW - X-ray scattering PY - 2024 AN - OPUS4-61334 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Small-angle scattering for everyone: How to unlock the power of this ancient technique N2 - The obscure, yet fundamental technique of scattering can unlock essential information on the fine structure of materials. For you, it can help you understand how your batteries charge, how squid backbones work, or how hundreds of small variations in your syntheses affect your samples. As a nondestructive technique, it also measures your materials *in situ* or operando, as you pull it, heat it, electrify it, or align it one way or another. Scattering can be done using light, X-rays, neutrons, and even electrons, giving you the choice on which probe is best for you. The only downside? Scattering will always remain a complicated technique to do right. The technique gives you only one piece of information: the length distribution of density in your sample. How you interpret this (rather abstract) piece of information is up to you and your samples. Unlike microscopy, where the real-space image can be interpreted almost intuitively and artefacts are easier to spot, in scattering you cannot always easily identify artefacts. Therefore, the only way to do scattering experiments correctly is through rigour and care. For those of us with that particular eccentricity, seeing the rigour and care pay off is exhilarating, and opens the door to a life of happiness and excitement. This lecture will introduce scattering (in particular using X-rays and neutrons), what it is, what you can (and cannot) get out of it, and how to approach your scattering experiment. Regarding the experimental section, it will discuss the five parts that make up a successful scattering experiment based on real-life examples: Preparation: which and how you prepare your samples affects what you can get out of the interpretation Measurement: The machine design and your measurement choices dictates the final quality of your data Correction: Obtaining trustworthy scattering curves will greatly improve the speed and quality of your analysis. Analysis: Do you linearize, use generic scattering models, perform classical least-squares fitting, play with Monte-Carlo analysis or transform your data.. Some tips to help you make a choice. Interpretation: what does the analysis of all your samples tell you? Can you fit the puzzle pieces together to form a piece of knowledge? For further information, please feel free to explore the https://lookingatnothing.com/ weblog, the https://youtube.com/drheaddamage video channel, or by asking me in person or by email for specific questions at brian.pauw@bam.de . Some introductory reading can be found in the following papers: Pauw, B. R. (2013): Everything SAXS: small-angle scattering pattern collection and correction. _J. Phys.: Condens. Matter_ 25: 383201. DOI: [10.1088/0953-8984/25/38/383201](http://dx.doi.org/10.1088/0953-8984/25/38/383201) B. R. Pauw, A. J. Smith, T. Snow, N. J. Terrill, A. F. Thünemann, (2017): The modular SAXS data correction sequence for solids and dispersions, _Journal of Applied Crystallography_, 50: 1800–1811, DOI: [10.1107/S1600576717015096](https://doi.org/10.1107/S1600576717015096) G. J. Smales, B. R. Pauw (2021): The MOUSE project: a meticulous approach for obtaining traceable, wide-range X-ray scattering information. _Journal of instrumentation_ 16 (6) P06034. DOI: [10.1088/1748-0221/16/06/P06034](https://doi.org/10.1088/1748-0221/16/06/P06034) T2 - SAS School at the XIX International Small Angle Scattering Conference CY - Taipei, Taiwan DA - 02.11.2024 KW - X-ray scattering KW - Neutron scattering KW - Scattering KW - X-ray KW - Neutron KW - Introduction KW - Methodology PY - 2024 AN - OPUS4-61623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Foroutan, F. A1 - Kyffin, B. A. A1 - Nikolaou, A. A1 - Merino-Gutierrez, J. A1 - Abrahams, I. A1 - Kanwal, N. A1 - Knowles, J. C. A1 - Smith, A. J. A1 - Smales, Glen Jacob A1 - Carta, D. T1 - Highly porous phosphate-based glasses for controlled delivery of antibacterial Cu ions prepared via sol–gel chemistry N2 - Mesoporous glasses are a promising class of bioresorbable biomaterials characterized by high surface area and extended porosity in the range of 2 to 50 nm. These peculiar properties make them ideal materials for the controlled release of therapeutic ions and molecules. Whilst mesoporous silicate-based glasses (MSG) have been widely investigated, much less work has been done on mesoporous phosphate-based glasses (MPG). In the present study, MPG in the P2O5–CaO–Na2O system, undoped and doped with 1, 3, and 5 mol% of Cu ions were synthesized via a combination of the sol–gel method and supramolecular templating. The non-ionic triblock copolymer Pluronic P123 was used as a templating agent. The porous structure was studied via a combination of Scanning Electron Microscopy (SEM), Small-Angle X-ray Scattering (SAXS), and N2 adsorption–desorption analysis at 77 K. The structure of the phosphate network was investigated via solid state 31P Magic Angle Spinning Nuclear Magnetic Resonance (31P MAS-NMR) and Fourier Transform Infrared (FTIR) spectroscopy. Degradation studies, performed in water via Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES), showed that phosphates, Ca2+, Na+ and Cu ions are released in a controlled manner over a 7 days period. The controlled release of Cu, proportional to the copper loading, imbues antibacterial properties to MPG. A significant statistical reduction of Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) bacterial viability was observed over a 3 days period. E. coli appeared to be more resistant than S. aureus to the antibacterial effect of copper. This study shows that copper doped MPG have great potential as bioresorbable materials for controlled delivery of antibacterial ions. KW - Bioresorbable Biomaterials KW - Mesoporous phosphate-based glasses KW - Synthesis KW - Degradation studies KW - X-ray scattering KW - MOUSE KW - Antibacterial properties KW - Aantimicrobial PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-578101 DO - https://doi.org/10.1039/D3RA02958A VL - 13 IS - 29 SP - 19662 EP - 19673 PB - Royal Society of Chemistry AN - OPUS4-57810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, W. A1 - Schweins, R. A1 - Nöcker, B. A1 - Kohlbrecher, J. A1 - Smales, Glen Jacob A1 - Huber, K. T1 - Comparative study of the co-assembly behaviour of 3-chloro-4-hydroxy-phenylazo dyes with DTAB N2 - The co-assembly of three one-fold negatively charged 3-chloro-4-hydroxy-phenylazo dyes (Yellow, Blue and Red) with the cationic surfactant dodecyltrimethylammoniumbromide (DTAB) was studied to probe dye–DTAB binding stoichiometry and assembly morphology. For each dye, phase separation was observed above a given dye : DTAB ratio with the ratio depending on the dye. While Yellow and DTAB showed liquid/liquid phase separation above Yellow : DTAB = 1 : 1.67, crystalline dye–DTAB complexes were observed for Blue–DTAB and Red–DTAB above Blue : DTAB = 1 : 2.56 and Red : DTAB = 1 : 2.94 respecively. In homogeneous solution, UV/vis spectroscopic investigations suggest stochiometries of Yellow : DTAB = 1 : 2, Blue : DTAB = 1 : 3 and Red : DTAB = 1 : 4. It was concluded, that Yellow exhibits the highest dye : DTAB binding stoichiometry in both, dye–surfactant complexes in the 2-phase region and in solution, whereas the lowest dye : DTAB binding stoichiometry was observed for Red–DTAB in both cases. The observed stoichiometries are inversely correlated to the impact dye addition has on the morphology of DTAB micelles. Generally, addition of dye to DTAB micelles leads to a reduction in spontaneous curvature of these micelles and to the formation of triaxial ellipsoidal or cylindrical micelles from oblate ellipsoidal DTAB micelles. At a DTAB concentration of 30 mM and a dye concentration of 5 mM, this effect was most pronounced for Red and least pronounced for Yellow, whilst Blue showed an intermediate effect. KW - Dye KW - DTAB KW - SAXS KW - Small-angle X-ray scattering KW - X-ray scattering KW - Data analysis KW - Micelle PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-576978 DO - https://doi.org/10.1039/D3SM00501A SN - 1744-683X VL - 19 IS - 24 SP - 4588 EP - 4598 PB - Royal Society of Chemistry AN - OPUS4-57697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - What’s that beyond the grasslands? Expanding your world view via wide-range X-ray scattering N2 - This talk introduces the expanded view that comes from wide-range X-ray scattering investigations. Compared to X-ray diffraction studies alone, the additional angular range of this technique provides information on the larger structural dimensions present in your samples. This allows for the extraction of information on the size and size distribution of nanostructural components, such as nanoparticles, nanovoids, and any other structure exhibiting an electron density contrast. The talk introduces the technique, the MOUSE instrument used for these investigations, and provides several real-world examples of its uses. The audience is invited to choose which examples captures their interest from a range of options, in the latter segment of the talk. T2 - ECS8: European Crystallography School 2023 CY - Berlin, Germany DA - 18.06.2023 KW - X-ray scattering KW - Introduction KW - Fourier transforms KW - Nanostructure investigation KW - Instrument automation KW - MOUSE PY - 2023 AN - OPUS4-57769 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - How to manage a modern X-ray scattering lab – a modest example N2 - Introduction A good laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration). In the MOUSE, we have combined: a) a comprehensive laboratory workflow with b) a heavily modified, highly automated X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, with a well-documented data flow (akin to what is found at the more automated beamlines). With two full-time researchers, the lab collects and interprets thousands of datasets, on hundreds of samples for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data. While these numbers do not light a candle to those achieved by our hardworking compatriots at the synchrotron beamlines, the laboratory approach does allow us to continually modify and fine-tune the integral methodology. So for the last three years, we have incorporated e.g. FAIR principles, traceability, automated processing, data curation strategies, as well as a host of good scattering practices into the MOUSE system. We have concomitantly expanded our purview as specialists to include an increased responsibility for the entire scattering aspect of the resultant publications. This ensures full exploitation of the data quality, whilst avoiding common pitfalls. Talk scope This talk will present the MOUSE project as implemented to date, and will introduce foreseeable upgrades and changes. These upgrades include better pre-experiment sample scattering predictions to filter projects on the basis of their suitability, exploitation of the measurement database for detecting long-term changes and automated flagging of datasets, extending the measurement range through an Ultra-SAXS module, and enhancing MC fitting with sample scattering simulations for better matching of odd-shaped scatterers. T2 - 2021 joint virtual meeting of the African Light Source (AfLS), the African Physical Society (AfPS), and Pan African Conference on Crystallography (ePCCr) CY - Online meeting DA - 15.11.2021 KW - X-ray scattering KW - MOUSE KW - Instrumentation KW - SAXS KW - Methodology KW - Laboratory management KW - Databases KW - Data management KW - Data catalog KW - Scicat PY - 2021 UR - https://events.saip.org.za/event/170/contributions/7619/ AN - OPUS4-53811 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - More of the same, please! Standardizing a perfectionist X-ray Scattering methodology for labs and synchrotrons N2 - After a colleague sent me a more useful measurement from a laboratory instrument than what I could get from the beamline, I knew it was time to reassess my life's choices. Over the course of several subsequent post-doc and permanent positions around lab instruments, I managed to refine a flexible, comprehensive methodology for data collection, correction and analysis which can be applied to many X-ray scattering investigations at the lab and at the synchrotron. With the help of friends at round places, this methodology was implemented and put into production, and has been delivering high-quality data since then. Now, we have almost all possible data corrections (for X-ray scattering) implemented, and are improving the hardware to deliver higher-quality metadata to enable the corrections to be performed to a higher accuracy. Simultaneously, we have set up a mini-large facility at BAM with the MAUS, the Multi-scale Analyzer for Ultrafine Structures. The MAUS combines the freedom of a laboratory instrument, with the spectrum of users of a beamline: besides measuring our own samples, and performing our own machine and methodology developments, we have opened this instrument for collaboration with fellow scientists from within BAM and from external institutes and universities. Here, we provide a comprehensive support for these collaborations, guiding the user from concept to sample selection, to interpretation and analysis. In 2019, we have supported over 30 different projects this way, leading to seven co-authored publications involving the MAUS in that year alone. As the MAUS uses the latest iteration of our comprehensive measurement methodology, the data quality is unmatched by any other lab instrument, and fully traceable to boot. The freedom of the laboratory allows for more proof-of-principle experimentation than what is possible at the synchrotron. Therefore, the MAUS provides a good first (and sometimes final) step towards many experimental materials science investigations, nicely complementing the capabilities of the synchrotron. If and when more flux is needed, the step to the synchrotron is now smaller than ever, in particular with the same method T2 - Symposium on large scale facilities CY - BAM, Berlin, Germany DA - 09.03.2020 KW - Small angle scattering KW - Methodology KW - X-ray scattering PY - 2020 AN - OPUS4-51014 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - The Meticulous Approach: Fully traceable X-ray scattering data via a comprehensive lab methodology N2 - To find out if experimental findings are real, you need to be able to repeat them. For a long time, however, papers and datasets could not necessarily include sufficient details to accurately repeat experiments, leading to a reproducibility crisis. It is here, that the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration) tries to implement change – at least for small- and wide-angle X-ray scattering (SAXS/WAXS). In the MOUSE project, we have combined: a) a comprehensive laboratory workflow with b) a heavily modified, highly automated Xenocs Xeuss 2.0 instrumental component. This combination allows us to collect fully traceable scattering data, with a well-documented data flow (akin to what is found at the more automated beamlines). With two full-time researchers, the lab collects and interprets thousands of datasets, on hundreds of samples for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data. While these numbers do not light a candle to those achieved by our hardworking compatriots at the synchrotron beamlines, the laboratory approach does allow us to continually modify and fine-tune the integral methodology. So for the last three years, we have incorporated e.g. FAIR principles, traceability, automated processing, data curation strategies, as well as a host of good scattering practices into the MOUSE system. We have concomitantly expanded our purview as specialists to include an increased responsibility for the entire scattering aspect of the resultant publications, to ensure full exploitation of the data quality, whilst avoiding common pitfalls. This talk will discuss the MOUSE project1 as implemented to date, and will introduce foreseeable upgrades and changes. These upgrades include better pre-experiment sample scattering predictions to filter projects on the basis of their suitability, exploitation of the measurement database for detecting long-term changes and automated flagging of datasets, and enhancing MC fitting with sample scattering simulations for better matching of odd-shaped scatterers. T2 - S4SAS CY - Online meeting DA - 01.09.2021 KW - X-ray scattering KW - Methodology KW - MOUSE KW - Data organization KW - Automation KW - Traceability PY - 2021 AN - OPUS4-53273 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob T1 - Complete set of raw and processed datasets, as well as associated Jupyter notebooks for analysis, associated with manuscript entitled: "The MOUSE project: a practical approach for obtaining traceable, wide-range X-ray scattering information" N2 - This dataset is a complete set of raw, processed and analyzed data, complete with Jupiter notebooks, associated with the manuscript mentioned in the title. In the manuscript, we provide a "systems architecture"-like overview and detailed discussions of the methodological and instrumental components that, together, comprise the "MOUSE" project (Methodology Optimization for Ultrafine Structure Exploration). Through this project, we aim to provide a comprehensive methodology for obtaining the highest quality X-ray scattering information (at small and wide angles) from measurements on materials science samples. KW - X-ray scattering KW - Measurement methodology KW - Traceability derivation KW - Multi-scale measurements KW - Systems architecture KW - Nanomaterials PY - 2020 DO - https://doi.org/10.5281/zenodo.4312953 PB - Zenodo CY - Geneva AN - OPUS4-51825 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - The MOUSE project - A meticulous approach for obtaining traceable, wide-range X-ray scattering information N2 - Herein, we provide a "systems architecture"-like overview and detailed discussions of the methodological and instrumental components that, together, comprise the "MOUSE" project (Methodology Optimization for UltrafineStructure Exploration). The MOUSE project provides scattering information on a wide variety of samples, with traceable dimensions for both the scattering vector (q) and the absolute scattering cross-section (I). The measurable scattering vector-range of 0.012≤ q (nm-1) ≤ 92, allows information across a hierarchy of structures with dimensions ranging from ca. 0.1 to 400 nm. In addition to details that comprise the MOUSE project, such as the organisation and traceable aspects, several representative examples are provided to demonstrate its flexibility. These include measurements on alumina membranes, the tobacco mosaic virus, and dual-source information that overcomes fluorescence limitations on ZIF-8 and iron-oxide-containing carbon catalyst materials. KW - X-ray scattering KW - MOUSE KW - Instrumentation KW - SAXS KW - Methodology KW - Traceability KW - Wide-range KW - Data curation KW - FAIR KW - Uncertainties KW - Nanomaterials KW - Nanometrology PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-528669 DO - https://doi.org/10.1088/1748-0221/16/06/P06034 VL - 16 IS - 6 SP - 1 EP - 50 PB - IOP CY - Bristol, UK AN - OPUS4-52866 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Omar, Hassan A1 - Smales, Glen Jacob A1 - Henning, S. A1 - Li, Z. A1 - Wang, D.-Y. A1 - Schönhals, Andreas A1 - Szymoniak, Paulina T1 - Calorimetric and Dielectric Investigations of Epoxy-Based Nanocomposites with Halloysite Nanotubes as Nanofillers N2 - Epoxy nanocomposites are promising materials for industrial applications (i.e., aerospace, marine and automotive industry) due to their extraordinary mechanical and thermal properties. Here, the effect of hollow halloysite nanotubes (HNT) on an epoxy matrix (Ep) was the focus of the study. The structure and molecular mobility of the nanocomposites were investigated using a combination of X-ray scattering, calorimetry (differential (DSC) and fast scanning calorimetry (FSC)) and dielectric spectroscopy. Additionally, the effect of surface modification of HNT (polydopamine (PDA) and Fe(OH)3 nanodots) was considered. For Ep/HNT, the glass transition temperature (Tg) is was de-creased due to a nanoparticle-related decrease of the crosslinking density. For the modified system, Ep/m-HNT, the surface modification resulted in enhanced filler–matrix interactions leading to higher Tg values than the pure epoxy in some cases. For Ep/m-HNT, the amount of interface formed between the nanoparticles and the matrix ranged from 5% to 15%. Through BDS measurements, localized fluctuations were detected as a β- and γ-relaxation, related to rotational fluctuations of phenyl rings and local reorientations of unreacted components. A combination of calorimetry and BDS dielectric spectroscopy revealed a dynamic and structural heterogeneity of the matrix, as confirmed by two glassy dynamics in both systems, related to regions with different crosslinking densities. KW - Rigid amorphous fraction KW - Epoxy nanocomposites KW - Halloysite nanotubes KW - X-ray scattering KW - Differential scanning calorimetry KW - Broadband dielectric spectroscopy KW - Flash DSC PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-526668 DO - https://doi.org/10.3390/polym13101634 VL - 13 IS - 10 SP - 1634 PB - MDPI AN - OPUS4-52666 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - X-ray Scattering for Nanostructure Quantification, and the Quest for the Perfect Experiment N2 - Compared to the clear, real-space images you can get from electron microscopy, X-ray scattering patterns are rather featureless. These patterns, however, contain structural information from all of the material structure illuminated by the X-ray beam. With this technique, you can measure nanoparticle dispersions, catalysts, composites, MOF powders, battery materials, light metal alloys and gels to reveal information on the structural features found within these materials. We have even measured many such materials for several research groups from the University of Birmingham, revealing structure features in the sub-nm to the micrometer range. Measuring an X-ray scattering pattern is relatively easy, but measuring a high-quality, useful pattern requires significant effort and good laboratory organization. Such laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration) [1]. With the MOUSE, we have combined: a) a comprehensive and highly automated laboratory workflow with b) a heavily modified X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, within a well-documented, FAIR-compliant data flow (akin to what is found at the more automated synchrotron beamlines). With two full-time researchers, our lab collects and interprets thousands of datasets, on hundreds of samples, for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data. T2 - School of Chemistry Seminars CY - Birmingham, UK DA - 10.11.2021 KW - X-ray scattering KW - MOUSE KW - Instrumentation KW - SAXS KW - Methodology KW - Nanostructure PY - 2021 UR - https://www.youtube.com/watch?v=N2kY4wbqeM4 AN - OPUS4-53810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - "Ultima Ratio": Multi-scale, high-resolution 3D-FFT scattering pattern simulations N2 - This talk highlights a proof-of-concept that demonstrates the ability to calculate high-resolution Fourier transforms. These can be combined with multi-scale modeling to simulate scattering over a wide range, from small-angle scattering to XRD and PDF. T2 - Shapespyer/MuSSIC Launch Workshop CY - Didcot, UK DA - 20.02.2023 KW - X-ray scattering KW - Simulation KW - Fourier Transform KW - 3D KW - High resolution KW - Multi-scale PY - 2023 AN - OPUS4-57031 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dal Molin, E. S. A1 - Henning, L. M. A1 - Müller, J. T. A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard A1 - Bekheet, M. F. A1 - Gurlo, A. A1 - Simon, U. T1 - Robocasting of ordered mesoporous silica‐based monoliths: Rheological, textural, and mechanical characterization N2 - Hierarchically porous, high‐surface‐area silica materials are excellent candidates for multiple applications like catalysis and environmental remediation. Shaping these materials with additive manufacturing (AM) techniques, like robocasting, could enable their use with the benefit of on‐demand, customized shaping and maximizing performance. Herein, ordered mesoporous silica COK‐12 slurries were robocasted into monoliths, containing different ratios of uncalcined COK‐12 and sodium bentonite (0–25 wt.%). The rheology of the mixed slurries is characterized by lower flow indexes (0.69 vs. 0.32) and higher yield stresses (96 vs. 259 Pa) compared to pure COK‐12 ones. Monoliths were printed in woodpile structures and calcined at 600°C. Micro‐CT measurements showed a linear shrinkage of 25% after calcination. Mechanical characterization showed increased uniaxial strength (0.20 ± 0.07 to 1.0 ± 0.3 MPa) with increasing binder/solids ratio from 13 to 25%. The amorphous, mesoporous structure of COK‐12 was retained. The structures exhibited open porosities of 52 ± 4% and showed higher specific mesopore volumes, and increased average mesopore size (6 vs. 8 nm) compared to COK‐12. Small‐angle x‐ray scattering analysis revealed an increased lattice parameter (10.3 vs. 11.0 nm) and reduced wall thickness (3.1 nm vs. 4.1 nm) of the COK‐12 in the monoliths. These properties indicate suitability for their application as porous supports and adsorbents. KW - Industrial and Manufacturing Engineering KW - Additive manufacturing KW - OMS KW - Porous materials KW - Robocasting KW - X-ray scattering KW - MOUSE PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-582503 DO - https://doi.org/10.1002/nano.202300109 VL - 4 IS - 11-12 SP - 615 EP - 631 PB - Wiley-VCH GmbH AN - OPUS4-58250 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hallier, Dorothea C. A1 - Smales, Glen Jacob A1 - Seitz, H. A1 - Hahn, Marc Benjamin T1 - Bio-SAXS of single-stranded DNA-binding proteins: Radiation protection by the compatible solute ectoine N2 - Small-angle X-ray scattering (SAXS) can be used for structural determination of biological macromolecules and polymers in their native states (e.g. liquid phase). This means that the structural changes of (bio-)polymers, such as proteins and DNA, can be monitored in situ to understand their sensitivity to changes in chemical environments. In an attempt to improve the reliability of such experiments, the reduction of radiation damage occurring from exposure to X-rays is required. One such method, is to use scavenger molecules to protect macromolecules against radicals produced during radiation exposure, such as reactive oxygen species (ROS). In this study we investigate the feasibility of applying the compatible solute, osmolyte and radiation protector Ectoine (THP(B)), as a scavenger molecule during SAXS measurements of the single-stranded DNA-binding protein Gene-V Protein (G5P/GVP). In this case, we monitor the radiation induced changes of G5P during bio-SAXS measurments and the resulting microscopic energy-damage relation was determined from microdosimetric calculations by Monte-Carlo based particle scattering simulations with TOPAS/Geant4 and a custom target-model. This resulted in a median-lethal energy deposit of pure G5P at 4 mg mL−1 of E1/2 = 7 ± 5 eV, whereas a threefold increase of energy-deposit was needed under the presence of Ectoine to reach the same level of damage. This indicates that Ectoine increases the possible exposure time before radiation-damage to G5P is observed. Furthermore, the dominant type of damage shifted from aggregation in pure solutions towards a fragmentation for solutions containing Ectoine as a cosolute. These results are interpreted in terms of indirect radiation damage by reactive secondary species, as well as post-irradiation effects, related to preferential-exclusion of the cosolute from the protein surface. Hence, Ectoine is shown to provide a non-disturbing way to improve structure-determination of proteins via bio-SAXS in future studies. KW - BioSAXS KW - Bio-SAXS KW - Cosolute KW - Ectoine KW - G5P KW - GVP KW - Radiation damage KW - Radical Scavenger KW - Single-stranded DNA-binding proteins KW - X-ray scattering KW - DNA KW - ssDNA KW - Protein KW - SAXS KW - Small-angle xray scattering KW - McSAS3 KW - Dosimetry KW - Microdosimetry KW - Geant4 KW - Geant4-DNA KW - Topas KW - Topas-MC KW - Monte-Carlo simulations KW - Particle scattering simulations KW - Topas-nBio KW - OH Radical KW - OH radical scavenger KW - LEE KW - Ionizing radiation damage KW - Protein unfolding KW - Ectoin PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-568909 DO - https://doi.org/10.1039/d2cp05053f SN - 1463-9076 SN - 1463-9084 VL - 25 IS - 7 SP - 5372 EP - 5382 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-56890 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hallier, Dorothea C. A1 - Smales, Glen Jacob A1 - Seitz, H. A1 - Hahn, Marc Benjamin T1 - Inside back cover for the article "Bio-SAXS of single-stranded DNA-binding proteins: Radiation protection by the compatible solute ectoine" N2 - Showcasing research from the Federal Institute for Material Research and Testing Berlin and Fraunhofer Institute for Celltherapy and Immunology Branch Bioanalytics and Bioprocesses Potsdam. Bio-SAXS of single-stranded DNA-binding proteins: Radiation protection by the compatible solute ectoine. We aimed to increase the possible undisturbed exposure time during bio-SAXS measurements of single-stranded DNA-binding proteins. Therefore small angle X-ray scattering was performed on Gene-V Protein (G5P/GVP), which is involved in DNA repair processes. To achieve this, irradiations were performed in presence and absence of the hydroxyl-radical scavenger and osmolyte Ectoine, which showed efficient radiation protection and prevented protein aggregation, thus allows for a non-disturbing way to improve structure-determination of biomolecules. KW - Bio-SAXS KW - BioSAXS KW - Cosolute KW - DNA KW - Dosimetry KW - Ectoin KW - Ectoine KW - G5P KW - GVP KW - Geant4 KW - Geant4-DNA KW - Ionizing radiation damage KW - LEE KW - McSAS3 KW - Microdosimetry KW - Monte-Carlo simulations KW - OH Radical KW - OH radical scavenger KW - Protein KW - Protein unfolding KW - Radiation damage KW - Radical Scavenger KW - SAXS KW - Single-stranded DNA-binding proteins KW - Small-angle xray scattering KW - Topas-MC KW - Topas-nBio KW - TopasMC KW - X-ray scattering KW - Particle scatterin simulations KW - ssDNA PY - 2023 DO - https://doi.org/10.1039/D3CP90056H SN - 1463-9076 SN - 1463-9084 VL - 25 IS - 7 SP - 5889 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-57006 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hahn, Marc Benjamin T1 - Extending Bio-SAXS measurements of Single-Stranded DNA-Binding Proteins: Radiation Protection of G5P by Cosolutes N2 - Small-angle X-ray scattering (SAXS) can be used for structural de- termination of biological macromolecules and polymers in their na- tive states. To improve the reliability of such experiments, the re- duction of radiation damage occurring from exposure to X-rays is needed.One method, is the use of scavenger molecules that protect macromolecules against radicals produced by radiation exposure.In this study we investigate the feasibility to apply the compatible solute, osmolyte and radiation protector Ectoine (THP(B)) as a scavenger throughout SAXS measurements of single-stranded DNA-binding protein Gene-V Protein (G5P/GVP). Therefore we monitor the radiation induced changes of G5P during bio-SAXS. The resulting microscopic energy-damage relation was determined by particle scattering simu- lations with TOPAS/Geant4. The results are interpreted in terms of radical scavenging as well as post-irradiation effects, related to preferential-exclusion from the protein surface. Thus, Ectoine provides an non-disturbing way to improve structure-determination of proteins via bio-SAXS in future studies. T2 - MultiChem Conference 2023 CY - Prague, Czech Republic DA - 26.04.2023 KW - Bio-SAXS KW - BioSAXS KW - Compatible solute KW - Cosolute KW - DNA KW - Dosimetry KW - Ectoin KW - Ectoine KW - Ectoin KW - G5P KW - GVP KW - Geant4 KW - Geant4-DNA KW - Gene five protein KW - Hydroxyectoine KW - Ionizing radiation damage KW - LEE KW - McSAS3 KW - Microdosimetry KW - Monte-Carlo simulations KW - OH Radical KW - OH radical scavenger KW - Osmolyte KW - Particle scattering simulations KW - Protein KW - Protein unfolding KW - Proteins KW - ROS KW - Radiation damage KW - Radical Scavenger KW - Radical scavenger KW - SAXS KW - Single-stranded DNA-binding proteins KW - Small-angle xray scattering KW - Topas KW - Topas-MC KW - Topas-nBio KW - X-ray scattering KW - ssDNA KW - Median lethal energy deposit PY - 2023 AN - OPUS4-57407 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - X-ray Scattering USAXS/SAXS/WAXS (/XRD/PDF) N2 - A ten minute introduction to the technique of X-ray scattering. This talk discusses the foundation and the resulting morphological parameters that can be obtained from the technique. The talk is prepared for discussion within the framework of the OECD REACH guideline for nanomaterials. T2 - Digitaler Info-Tag "Nano or not Nano" CY - Berlin, Germany DA - 16.02.2023 KW - X-ray scattering KW - BAM Academy KW - SAXS KW - XRD KW - WAXS KW - Nanomaterial KW - REACH KW - OECD KW - Guideline PY - 2023 AN - OPUS4-57013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Reimagining user-driven science N2 - The materials scientists we work with do not want (or need) to learn the ways of the scatterer; they are primarily interested in obtaining trustworthy, authoritative answers. In particular, they need structural understanding in light of the wider framework of their experiment(s). Our interest, therefore, lies in helping them attain this this interconnected understanding, while using such investigations to further hone our methodology to approximate perfection. While perfection is by definition an unattainable goal, we have spent the last 15+ years exploring and expanding on many of its constituent aspects (often together with likeminded people) [1]. These aspects include: developing various visualization and simulation tools, deconstructing data corrections and uncertainty estimation, advancing analysis methods, quantifying questions on traceability, documentation, reproducible automation of synthesis-, measurement- and data pipelines, data visualization, exploration and education, and many more… As we explored these individual aspects, it has become clear that high quality output demands involving ourselves in the entire experimental workflow, with all associated aspects. This allows you to establish trustworthy links between parameters, structure, and performance. Through multiple cross-checks and validations, we can furthermore assign a degree of confidence to our findings. This is what we call the holistic approach. This talk will briefly define perfection in scattering experiments, expand on the holistic approach, and show examples to demonstrate its benefits. T2 - Invited talk - special event CY - Trieste, Italy DA - 15.05.2025 KW - X-ray scattering KW - Holistic experiments KW - Laboratory management KW - Laboratory automation KW - Data stewardship KW - User support PY - 2025 AN - OPUS4-63372 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard T1 - McSAS3 N2 - McSAS3 is a refactored version of the original McSAS (see DOI 10.1107/S1600576715007347). This software fits scattering patterns to obtain size distributions without assumptions on the size distribution form. The refactored version has some neat features: - Multiprocessing is included, spread out over as many cores as number of repetitions! - Full state of the optimization is stored in an organized HDF5 state file. - Histogramming is separate from optimization and a result can be re-histogrammed as many times as desired. - SasModels allow a wide range of models to be used - If SasModels does not work (e.g. because of gcc compiler issues on Windows or Mac), an internal sphere model is supplied - Simulated data of the scattering of a special shape can also be used as a McSAS fitting model. Your models are infinite! - 2D fitting also works. KW - X-ray scattering KW - Polydispersity KW - Monte carlo KW - Scattering pattern analysis KW - Analysis approach KW - Neutron scattering KW - Automation KW - Command line PY - 2023 DO - https://doi.org/10.6084/m9.figshare.21814128.v1 PB - Digital Science CY - Cambridge, MA, USA AN - OPUS4-56787 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob T1 - X-ray scattering Datasets of gold and silver nanoparticle composites, relating to the publication "Gold and silver dichroic nanocomposite in the quest for 3D printing the Lycurgus cup" N2 - Wide-range X-ray scattering datasets and analyses for all samples described in the 2020 publication "Gold and silver dichroic nanocomposite in the quest for 3D printing the Lycurgus cup". These datasets are composed by combining multiple small-angle x-ray scattering and wide-angle x-ray scattering curves into a single dataset. They have been analyzed using McSAS to extract polydispersities and volume fractions. They have been collected using the MOUSE project (instrument and methodology). KW - X-ray scattering KW - MOUSE KW - Saxs KW - Waxs KW - Analyses KW - Datasets PY - 2022 DO - https://doi.org/10.5281/zenodo.7193859 PB - Zenodo CY - Geneva AN - OPUS4-55979 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - X-ray scattering for nanostructure quantification, and the quest for the perfect experiment N2 - Measuring an X-ray scattering pattern is relatively easy, but measuring a steady stream of high-quality, useful patterns requires significant effort and good laboratory organization. Such laboratory organization can help address the reproducibility crisis in science, and easily multiply the scientific output of a laboratory, while greatly elevating the quality of the measurements. We have demonstrated this for small- and wide-angle X-ray scattering in the MOUSE project (Methodology Optimization for Ultrafine Structure Exploration). With the MOUSE, we have combined a comprehensive and highly automated laboratory workflow with a heavily modified X-ray scattering instrument. This combination allows us to collect fully traceable scattering data, within a well-documented, FAIR-compliant data flow (akin to what is found at the more automated synchrotron beamlines). With two full-time researchers, our lab collects and interprets thousands of datasets, on hundreds of samples, for dozens of projects per year, supporting many users along the entire process from sample selection and preparation, to the analysis of the resulting data. This talk will briefly introduce the foundations of X-ray scattering, present the MOUSE project, and will highlight the proven utility of the methodology for materials science. Upgrades to the methodology will also be discussed, as well as possible avenues for transferring this holistic methodology to other instruments T2 - SNI 2022 CY - Berlin, Germany DA - 05.09.2022 KW - Methodology KW - X-ray scattering KW - Laboratory management KW - Instrumentation utilization KW - MOUSE KW - SAXS KW - WAXS KW - Automation PY - 2022 AN - OPUS4-55760 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Adamski, Paweł A1 - Zgrzebnicki, Michał A1 - Albrecht, Aleksander A1 - Jurkowski, Artur A1 - Wojciechowska, Agnieszka A1 - Ekiert, Ewa A1 - Sielicki, Krzysztof A1 - Mijowska, Ewa A1 - Smales, Glen J. A1 - Maximenko, Alexey A1 - Moszyński, Dariusz T1 - Ammonia synthesis over γ-Al2O3 supported Co-Mo catalysts N2 - Novel ammonia synthesis catalysts are sought due to energetic transformation and increasing environmental consciousness. Materials containing cobalt and molybdenum are showing state-of-art activities in ammonia synthesis. The application of γ-alumina support was proposed to enhance the properties of Co-Mo nanoparticles. The wet impregnation of the support was conducted under reduced pressure. The active catalysts were obtained by ammonolysis of precursors. The chemical and phase composition, as well as morphology, porosity, and surface composition of precursors and catalysts, were characterized. The Co-Mo nanoparticles phase composition as well as their size and dispersion were determined using X-ray absorption spectroscopy utilizing synchrotron radiation, electron microscopy, and X-ray scattering. The catalytic activity was tested in the ammonia synthesis process under atmospheric pressure. The activity and stability of the supported catalysts were compared with unsupported cobalt molybdenum nitride Co3Mo3N, revealing the superiority of the present approach. KW - Ammonia synthesis KW - Supported catalyst KW - Cobalt molybdenum nitrides KW - Scattering KW - X-ray scattering KW - Gamma-alumina KW - Stability PY - 2025 DO - https://doi.org/10.1016/j.mcat.2025.114907 SN - 2468-8231 VL - 575 SP - 1 EP - 9 PB - Elsevier B.V. AN - OPUS4-64827 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hörmann, Anja Franziska T1 - extending the MOUSE in spirit: lifecycle of a GIXS experiment N2 - We present the new grazing incidence mode at the MOUSE, which adapts and extends the MOUSE methodology developed for transmission X-ray scattering (Smales and Pauw, 2021). Our methodology begins and ends in discussion with our users and embraces automation for reproducible experiments including sample organisation, instrument configuration, documentation and data processing. This poster presents methodological innovations and challenges. T2 - GISAXS 2025 CY - Hamburg, Germany DA - 27.10.2025 KW - Grazing incidence KW - X-ray scattering KW - Experimental methodology PY - 2025 AN - OPUS4-64694 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - VIDEO A1 - Pauw, Brian Richard T1 - The human factor: A round robin study on the variation in data analyses N2 - This is a remote presentation I gave at the 2022 Small-angle Scattering conference in Campinas, Brazil. The video has been obtained from the conference organisers with their explicit permission for use on YouTube. I've tried to spruce up the audio from the remote recording the best I could. The conference abstract for this talk was: "How much do we, the small-angle scatterers, influence the results of an investigation? What uncertainty do we add by our human diversity in thoughts and approaches, and is this significant compared to the uncertainty from the instrumental measurement factors? After our previous Round Robin on data collection, we know that many laboratories can collect reasonably consistent small-angle scattering data on easy samples. To investigate the next, human component, we compiled four existing datasets from globular (roughly spherical) scatterers, each exhibiting a common complication, and asked the participants to apply their usual methods and toolset to the quantification of the results (https://lookingatnothing.com/index.php/archives/3274). Accompanying the datasets was a modicum of accompanying information to help with the interpretation of the data, similar to what we normally receive from our collaborators. More than 30 participants reported back with volume fractions, mean sizes and size distribution widths of the particle populations in the samples, as well as information on their self-assessed level of experience and years in the field. While the Round Robin is still underway (until the 25th of April, 2022), the initial results already show significant spread in the results. Some of these are due to the variety in interpretation of the meaning of the requested parameters, as well as simple human errors, both of which are easy to correct for. Nevertheless, even after correcting for these differences in understanding, a significant spread remains. This highlights an urgent challenge to our community: how can we better help ourselves and our colleagues obtain more reliable results, how could we take the human factor out of the equation, so to speak? In this talk, we will introduce the four datasets, their origins and challenges. Hot off the press, we will summarize the anonymized, quantified results of the Data Analysis Round Robin. (Incidentally, we will also see if a correlation exists between experience and proximity of the result to the median). Lastly, potential avenues for improving our field will be offered based on the findings, ranging from low-effort yet somehow controversial improvements, to high-effort foundational considerations." T2 - International Small-Angle Scattering Conference (SAS2022) CY - Campinas, Brazil DA - 11.09.2022 KW - Round robin KW - Data analysis KW - X-ray scattering KW - Neutron scattering KW - Nanomaterials KW - Metrology KW - Interlaboratory comparison PY - 2023 UR - https://www.youtube.com/watch?v=t1Rowo--Osg DO - https://doi.org/10.26272/opus4-56897 PB - YouTube, LLC CY - San Bruno, CA, USA AN - OPUS4-56897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - del Rocío Silva-Calpa, Leydi A1 - de Souza Bernardes, Andrelaine A1 - de Avillez, Roberto Ribeiro A1 - Smales, Glen J. A1 - Camarena, Mariella Alzamora A1 - Ramos Moreira, Carla A1 - Zaitsev, Volodymyr A1 - Archanjo, Braulio Soares A1 - Letichevsky, Sonia T1 - From support to shell: An innovative design of air-stable nano zero-valent iron–nickel catalysts via structural self-assembly N2 - This work presents the design of air-stable core–shell zero-valent iron–nickel nanofilaments supported on silica and zeolite, developed to overcome the oxidation limitations of nano zero-valent iron in environmental catalysis. The nanofilaments feature ∼ 100 nm iron–nickel cores surrounded by ultrafine iron-rich threads embedded with aluminates and silicates, originating from partial support dissolution during synthesis. By varying the iron reduction time, three catalysts were prepared: one on silica reduced for 30 min, and two on zeolite reduced for 30 and 15 min. They were thoroughly characterized using nitrogen physisorption, X-ray diffraction, electron microscopy with elemental analysis, Mössbauer spectroscopy, and small-angle X-ray scattering. The zeolite-supported catalyst reduced for 15 min showed the highest activity for hexavalent chromium reduction (rate constant 8.054 min−1), attributed to a higher fraction of reactive iron–nickel phases formed under shorter reduction. Its tailored core–shell structure improves air stability and surface reactivity, highlighting its potential as a next-generation zero-valent iron nanocatalyst for aqueous remediation KW - nanofilaments KW - Core–shell nanostructures KW - Air-stable nanomaterials KW - Structure-controlled FeNi nanoparticles KW - Hexavalent chromium reduction KW - X-ray scattering KW - MOUSE PY - 2025 DO - https://doi.org/10.1016/j.mtcomm.2025.114142 SN - 2352-4928 VL - 49 SP - 1 EP - 15677 PB - Elsevier Ltd. AN - OPUS4-65087 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Berry, Charlotte A. A1 - Reinart, Katre A1 - Smales, Glen J. A1 - Wilkinson, Holly N. A1 - Hardman, Matthew J. A1 - Marchesini, Sofia A1 - Lee, William A1 - Nery, Eveliny Tomás A1 - Moghaddam, Zarrin A1 - Hoxha, Agron A1 - Felipe-Sotelo, Mónica A1 - Gutierrez-Merino, Jorge A1 - Carta, Daniela T1 - Hierarchically porous copper and gallium loaded sol–gel phosphate glasses for enhancement of wound closure N2 - In this work, we have developed hierarchically porous phosphate-based glasses (PPGs) as novel materials capable of promoting wound closure and simultaneously delivering antibacterial effects at the glass-biological tissue interface. PPGs are characterised by extended porosity, which enhances the controlled release of therapeutic ions, whilst facilitating cell infiltration and tissue growth. Two series of PPGs in the systems P2O5–CaO–Na2O–CuO and P2O5–CaO–Na2O–Ga2O3 with (CuO and Ga2O3 0, 1, 5 and 10 mol%) were manufactured using a supramolecular sol–gel synthesis strategy. Significant wound healing promotion (up to 97%) was demonstrated using a human ex vivo wound model. A statistically significant reduction of the bacterial strains Staphylococcus aureus and Escherichia coli was observed in both series of PPGs, particularly those containing copper. All PPGs exhibited good cytocompatibility on keratinocytes (HaCaTs), and analysis of PPG dissolution products over a 7-day period demonstrated controlled release of phosphate anions and Ca, Na, Cu, and Ga cations. These findings indicate that Cu- and Ga-loaded PPGs are promising materials for applications in soft tissue regeneration given their antibacterial capabilities, in vitro biocompatibility with keratinocytes and ex vivo wound healing properties at the biomaterial-human tissue interface. KW - Porous glass KW - Phosphates KW - Wound healing materials KW - Antibacterial KW - X-ray scattering KW - MOUSE PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-650867 DO - https://doi.org/10.1039/d5tb01945a SN - 2050-750X VL - 13 IS - 48 SP - 15662 EP - 15677 PB - Royal Society of Chemistry (RSC) AN - OPUS4-65086 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob T1 - Raw and processed X-ray scattering datasets for: "Entering a new dimension in powder processing for advanced ceramics shaping" N2 - This dataset is a complete set of raw, processed and analyzed data, associated with the manuscript mentioned in the title. All associated metadata and processing history has been added. Particle size distribution analyses using McSAS are included as well. The samples consisted of a 4.2 mass% dispersion of yttria-stabilized zirconia nanoparticles in a cross-linked matrix. The measurements show a good dispersion with minimal agglomeration. The wide-angle region shows diffraction information consistent with zirconia. KW - X-ray scattering KW - Nanocomposite KW - Ceramic microprinting KW - Yttria-stabilized zirconia KW - SAXS KW - Nanomaterials KW - Two-photon polymerization KW - Transparency KW - Mechanical testing PY - 2023 DO - https://doi.org/10.5281/zenodo.7498647 PB - Zenodo CY - Geneva AN - OPUS4-56766 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cano Murillo, Natalia A1 - Szymoniak, Paulina A1 - Smales, Glen Jacob A1 - Sturm, Heinz A1 - Schönhals, Andreas T1 - Electrospun nanocomposites fibers of polycarbonate and taurine modified boehmite nanoparticles - What can be learned from structural and thermal investigations N2 - Though the reinforcing properties of inorganic particles in thermosetting nanocomposites, has been exploited, the integration of nanoparticles continues to be challenging in terms of their homogeneous distribution and their manipulation which can contribute to occupational hazards. Due to a second encapsulations of nanoparticles, electrospun nanocomposite fibers containing nanoparticles might be an alternative for overcoming these issues, as the fiber nonwovens contains the nanoparticles allowing for safer manipulation. Here, the morphology, and the thermal properties of electrospun polycarbonate fibers containing taurine modified boehmite nanoparticles (BNP) are investigated by means of small and wide-angle X-ray scattering as well as fast scanning and temperature modulated fast scanning calorimetry for the first time. The latter techniques allow the investigation of the thermal properties of single fibers at heating rates up to 10^4 K s^-1 keeping its structure intact. A quantitative analysis of the scattering data reveals a porous structure of the fibers. The porous structure is quantified regarding the pore volume and the pore size. A constant amount of aggregation is found even for the highly BNP loaded fibers. Thermal analysis on the fibers reveals a rigid amorphous fraction (RAF) where it is known that RAF determinates the properties of a nanocomposite to a large extent. For the fibers RAF amounts up to 40 wt%, which is essential higher compared to equally formulated PC/BNP composite cast films. The RAF in the case of the fibers, is not only due to the presence of particles in the polymer but also due to orientation effects induced by the electrospinning process. KW - Nanocomposite fibers KW - Electrospinning KW - X-ray scattering KW - Fast scanning calorimetry KW - Rigid amorphous fraction PY - 2021 DO - https://doi.org/10.1021/acsapm.1c01265 VL - 3 IS - 12 SP - 6572 EP - 6585 PB - ACS AN - OPUS4-53871 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Szymoniak, Paulina A1 - Qu, Xintong A1 - Schönhals, Andreas A1 - Sturm, Heinz ED - Sinapius, M. ED - Ziegmann, G. T1 - Characterization of Polymer Nanocomposites N2 - The complex effect of nanoparticles on an epoxy-based and anhydride cured DGEBA/Boehmite nanocomposite with different particle concentrations is considered in this chapter. A combination of X-ray scattering, calorimetry (fast scanning and temperature modulated calorimetry) and dielectric spectroscopy was employed to characterize the structure, vitrification kinetics and the molecular dynamics of the nanocomposites. Firstly, the unfilled polymer was found to be intrinsically heterogeneous, showing regions with different crosslinking density, indicated by two separate dynamic glass transitions. Moreover, the glass transition temperature decreases with increasing nanoparticle concentration, as a result of changes in the crosslinking density. In addition, it was shown that the incorporation of nanoparticles can result in simultaneous increase in the number of mobile segments for low nanoparticle concentrations and on the other hand, for higher loading degrees the number of mobile segments decreases, due to the formation of an immobilized interphase. KW - Rigid amorphous fraction KW - Epoxy nanocomposites KW - X-ray scattering KW - Differential scanning calorimetry KW - Broadband dielectric spectroscopy KW - Flash DSC PY - 2021 DO - https://doi.org/10.1007/978-3-030-68523-2_4 SP - 55 EP - 77 PB - Springer Nature AN - OPUS4-52698 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Reusable data: putting the “Arr” in FAIR N2 - This talk demonstrates how to apply FAIR principles to data from actual scientific investigations. The reasons and practical benefits of FAIR data are highlighted. Several levels of reusability are discussed, i.e. the “trust me”-level, the “I’ll not need to repeat my measurement”-level, and the “you’ll not need to repeat my measurements”-level. Practical FAIR datafiles are explored and their information content highlighted. T2 - Reusability of Scientific Data for Matter CY - Online meeting DA - 13.11.2025 KW - Methodology KW - Metadata KW - FAIR KW - Reusability KW - X-ray scattering KW - Traceability PY - 2025 AN - OPUS4-65309 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gollwitzer, C. T1 - Computation of scattering curves for particles with arbitrary shapes using Debye’s formula N2 - Small-angle scattering data from particle dispersions with narrow size distributions are usually analysed by fitting a model function to the data, which is composed of a monodisperse form factor with a size distribution and, optionally, a structure factor. For common particle shapes like solid spheres, core-shell particles, ellipsoids or rods, the form factor can be computed analytically, and several software packages are readily available which provide a compilation of form factors.1,2 Recently, highly monodisperse nanoparticles with a variety of shapes have been synthesized, e.g. cubes and bipyramids3,4 with lightly capped edges, for which analytic form factors are harder to derive. We compute an approximation to the scattering curve of arbitrary shapes by filling the shape with a quasi-random distribution of point scatterers and using Debye’s formula to get the overall scattering curve. The highly optimized debyer code is used to perform an efficient evaluation of Debye’s formula,5 which can perform the evaluation of 500,000 point scatterers in two minutes on commodity hardware. Moderate polydispersity is handled by interpolating the computed scattering curve over q from a master curve. In this way, the code is fast enough to perform data fitting of particle ensembles with moderate polydispersity for arbitrary shapes to experimental data. This work was partly funded by the 17NRM04 nPSize project of the EMPIR programme co-financed by the EMPIR participating states and by the European Union’s Horizon 2020 research and innovation programme. T2 - 17th Nordic Workshop on Scattering from Soft Matter CY - Linköping, Sweden DA - 14.01.2020 KW - X-ray scattering KW - Nanoparticles KW - Particle shape KW - Modelling KW - Form factor PY - 2020 UR - http://nssm2020.se/ AN - OPUS4-50368 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - VIDEO A1 - Pauw, Brian Richard T1 - How to run a (lab) SAXS instrument efficiently N2 - Here I talk about our holistic approach to X-ray scattering, and what improvements we made to our methodology to make measuring with us a very streamlined process. KW - Laboratory management KW - MOUSE KW - X-ray scattering KW - Instrument utilization KW - Research efficiency KW - Automation KW - Metadata collection KW - Laboratory automation PY - 2022 UR - https://www.youtube.com/watch?v=ncadUQ43Uwc DO - https://doi.org/10.26272/opus4-55761 PB - YouTube, LLC CY - San Bruno, CA, USA AN - OPUS4-55761 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - VIDEO A1 - Pauw, Brian Richard T1 - Just a minute: X-ray scattering N2 - An extremely brief summary of what X-ray scattering can do for you (X-ray scattering encompasses small-angle X-ray scattering (SAXS), and wide-angle X-ray scattering (WAXS/XRD), amongst others). See my other videos for more detailed explanations on sample selection, data correction, data analysis, etc. KW - X-ray scattering KW - Introduction KW - Materials science KW - Nanostructure investigation KW - MOUSE PY - 2022 UR - https://www.youtube.com/watch?v=jWWNQyaCTHA DO - https://doi.org/10.26272/opus4-55768 PB - YouTube, LLC CY - San Bruno, CA, USA AN - OPUS4-55768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Pauw, Brian Richard A1 - Laskina, Sofya A1 - Naik, Aakash A1 - Smales, Glen Jacob A1 - George, Janine A1 - Breßler, Ingo A1 - Benner, Philipp T1 - "Ultima Ratio": Simulating wide-range X-ray scattering and diffraction N2 - We demonstrate a strategy for simulating wide-range X-ray scattering patterns, which spans the small- and wide scattering angles as well as the scattering angles typically used for Pair Distribution Function (PDF) analysis. Such simulated patterns can be used to test holistic analysis models, and, since the diffraction intensity is on the same scale as the scattering intensity, may offer a novel pathway for determining the degree of crystallinity. The "Ultima Ratio" strategy is demonstrated on a 64-nm Metal Organic Framework (MOF) particle, calculated from Q < 0.01 1/nm up to Q < 150 1/nm, with a resolution of 0.16 Angstrom. The computations exploit a modified 3D Fast Fourier Transform (3D-FFT), whose modifications enable the transformations of matrices at least up to 8000^3 voxels in size. Multiple of these modified 3D-FFTs are combined to improve the low-Q behaviour. The resulting curve is compared to a wide-range scattering pattern measured on a polydisperse MOF powder. While computationally intensive, the approach is expected to be useful for simulating scattering from a wide range of realistic, complex structures, from (poly-)crystalline particles to hierarchical, multicomponent structures such as viruses and catalysts. KW - X-ray KW - Simulation KW - 3D Fourier Transform KW - High resolution KW - XRD KW - SAXS KW - PDF KW - Total scattering KW - X-ray scattering KW - Metal organic framework KW - Electron density map KW - FFT PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-572067 DO - https://doi.org/10.48550/arXiv.2303.13435 VL - Cornell University SP - 1 EP - 12 PB - Ithaca, NY AN - OPUS4-57206 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob A1 - Anker, A. S. A1 - Balazs, D. M. A1 - Beyer, F. L. A1 - Bienert, Ralf A1 - Bouwman, W. G. A1 - Breßler, Ingo A1 - Breternitz, J. A1 - Brok, E. S. A1 - Bryant, G. A1 - Clulow, A. J. A1 - Crater, E. R. A1 - De Geuser, F. A1 - Giudice, A. D. A1 - Deumer, J. A1 - Disch, S. A1 - Dutt, S. A1 - Frank, K. A1 - Fratini, E. A1 - Gilbert, E. P. A1 - Hahn, Marc Benjamin A1 - Hallett, J. A1 - Hohenschutz, Max A1 - Hollamby, M. J. A1 - Huband, S. A1 - Ilavsky, J. A1 - Jochum, J. K. A1 - Juelsholt, M. A1 - Mansel, B. W. A1 - Penttilä, P. A1 - Pittkowski, R. K. A1 - Portale, G. A1 - Pozzo, L. D. A1 - Ricardo de Abreu Furtado Garcia, P. A1 - Rochels, L. A1 - Rosalie, Julian A1 - Saloga, P. E. J. A1 - Seibt, S. A1 - Smith, A. J. A1 - Smith, G. N. A1 - Annadurai, V. A1 - Spiering, G. A. A1 - Stawski, Tomasz A1 - Taché, O. A1 - Thünemann, Andreas A1 - Toth, K. A1 - Whitten, A. E. A1 - Wuttke, J. T1 - The human factor - Results of a small-angle scattering data analysis round robin N2 - A Round Robin study has been carried out to estimate the impact of the human element in small-angle scattering data analysis. Four corrected datasets were provided to participants ready for analysis. All datasets were measured on samples containing spherical scatterers, with two datasets in dilute dispersions, and two from powders. Most of the 46 participants correctly identified the number of populations in the dilute dispersions, with half of the population mean entries within 1.5 % and half of the population width entries within 40 %, respectively. Due to the added complexity of the structure factor, much fewer people submitted answers on the powder datasets. For those that did, half of the entries for the means and widths were within 44 % and 86 % respectively. This Round Robin experiment highlights several causes for the discrepancies, for which solutions are proposed. KW - Round robin KW - Sall-angle scattering KW - Nanostructure quantification KW - Nanostructure KW - SAXS KW - MOUSE KW - X-ray scattering KW - Size distribution KW - Nanoparticles PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-571342 DO - https://doi.org/10.48550/arXiv.2303.03772 SP - 1 EP - 23 PB - Cornell University CY - Ithaca, NY AN - OPUS4-57134 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - A place for everything: traceable science using metadata from syntheses and characterisation N2 - In our laboratory, we rely heavily on automation for synthesis and measurement. Done right, automation can deliver reliable quantities of excruciatingly detailed data, produced in a reproducible and traceable way. This data then needs sorting and organising, and a good structure of metadata is a good start to long-lasting data. This metadata collection is an essential part of our “holistic experimentation”-approach. In this approach, we try to ensure that all aspects of the experimental chain are performed to a high standard, so that experimental integrity is maintained. In other words: as a failure in one of the components of the chain can make an entire experiment worthless, we must ensure each component is done (and documented) well. In this talk, we show how we 1) synthesise well-documented sample series, 2) apply a complete end-to-end X-ray scattering characterisation methodology to those samples, and 3) can link the data from the synthesis to the structural details obtained from the scattering experiments in a visual dashboard. Furthermore, we will show examples on how data can be organised in hierarchical structures in HDF5-based datafiles, and how this helps move towards more trustworthy, traceable science. About the speaker: Brian Pauw is a full-stack X-ray scattering expert with over 15 years of experience in materials science. After earning a Ph.D. in Chemical Engineering from the Technical University of Denmark in 2009, Brian advanced scattering techniques at Japan’s National Institute for Materials Science before joining BAM (Federal Institute for Materials Research and Testing) in Germany as a permanent researcher. At BAM, Brian focuses on small-angle scattering of polymers, metals, catalysts, and more – developing precise methodologies for data collection, correction, and analysis. They also lead efforts in laboratory automation, including robotic systems for reproducible sample preparation, aiming to enhance the efficiency and reliability of experimental workflows. T2 - Helmholtz Metadata Collaboration: FAIR Friday Lecture Series CY - Online meeting DA - 09.05.2025 KW - Methodology KW - X-ray scattering KW - Traceability KW - Data provenance KW - Metadata KW - Lab automation KW - Holistic science PY - 2025 AN - OPUS4-63078 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Glimpses of the Future : Advancing X-ray Scattering in an Automated Materials Research Laboratory N2 - In our (dramatically understaffed) X-ray scattering laboratory, developing a systematic, holistic methodology1 let us provide scattering and diffraction information for more than 2100 samples for 200+ projects led by 120+ collaborators. Combined with automated data correction pipelines, and our analysis and simulation software, this led to more than 40 papers2 in the last 5 years with just over 2 full-time staff members. This year, our new, modular synthesis platform has made more than 1000 additional samples for us to analyse and catalogue. By virtue of the automation, the synthesis of these samples is automatically documented in excruciating detail, preparing them for upload and exploitation in large-scale materials databases. Having developed these proof-of-concepts, we find that materials research itself is changed dramatically by automating dull tasks in a laboratory. This talk is intended to spark ideas and invite collaborations by providing an overview of: 1) the current improvements in our wide-range X-ray scattering laboratory methodology, 2) Introduce some of our open-source analysis and simulation software, touching on scattering, diffraction and PDF, and 3) introducing our open, modular robotic platform for systematic sample preparation. Finally, the remaining bottlenecks and points of attention across all three are highlighted. T2 - Swiss Society for Crystallography (SSCr) annual meeting CY - Zurich, Switzerland DA - 08.09.2023 KW - Lab automation KW - Fourier transforms KW - X-ray scattering KW - Robotic synthesis KW - Data stewardship KW - Holistic experimental procedures KW - MOUSE KW - Metal-organic frameworks KW - High-throughput measurements PY - 2023 AN - OPUS4-58237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Synthesizing a library of 1000+ reproducible MOFs N2 - While the synthesis of Metal-Organic Framework (MOF) particles can be as easy as adding two solutions together, reproducibly obtaining the same particles, time and time again, is a lot harder. As laboratory-independent reproducibility is a cornerstone of the scientific method, we must put effort into finding and controlling all necessary parameters to achieve this. An open-source Python/EPICS-controlled robotic platform (see picture) was adapted to systematically explore this for a 20 ml MOF synthesis of the Zeolitic Imidazole Framework-8 (ZIF-8) chemistry in methanol. Parameters that were explored included: 1) addition sequence, 2) addition speeds, 3) reaction times, 4) source chemicals, 5) stirring speeds, 6) stirring bar choice, 7) starting concentrations, and 8) workup methodologies. It was found that, by controlling these parameters, highly reproducible syntheses are obtained. Secondly, the variation of these parameters alone led to a dramatic difference in volume-weighted particle size means, which exceeds an order of magnitude as investigated by our in-house X-ray scattering instrument [1]. The syntheses are thoroughly documented in an automated fashion, and the synthesis libraries as well as analyses libraries will become available in batches soon. With this library, it will be possible to extract previously unknown correlations, and other laboratories can produce specific particles by following the exact procedures of the particles of their choice. T2 - 787. WE-Heraeus-Seminar: Accelerated Discovery of New Materials CY - Bad Honnef, Germany DA - 15.05.2023 KW - Metal organic frameworks KW - Automation KW - Lab automation KW - Robotic-supported synthesis KW - Reproducibility KW - Synthesis library KW - X-ray scattering KW - Particle size distribution PY - 2023 AN - OPUS4-57596 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Digital Everything: X-ray Scattering and Synthesis Laboratories N2 - In our (dramatically understaffed) X-ray scattering laboratory, developing a systematic, holistic methodology let us provide scattering and diffraction information for more than 2100 samples for 200+ projects led by 120+ collaborators. Combined with automated data correction pipelines, and our analysis and simulation software, this led to more than 40 papers in the last 5 years with just over 2 full-time staff members. This year, our new, modular synthesis platform has made more than 1000 additional samples for us to analyse and catalogue. By virtue of the automation, the synthesis of these samples is automatically documented in excruciating detail, preparing them for upload and exploitation in large-scale materials databases. This talk is intended to spark ideas and invite collaborations by providing an overview of: 1) the current improvements in our wide-range X-ray scattering laboratory methodology, and 2) introducing our open, modular robotic platform for systematic sample preparation. T2 - Seminar at KIT CY - Karlsruhe, Germany DA - 17.08.2023 KW - Lab automation KW - Data stewardship KW - Scattering KW - X-ray scattering KW - Automated synthesis KW - Data pipelines PY - 2023 AN - OPUS4-58234 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Aliyah, K. A1 - Berger, A. A1 - Lazaridis, T. A1 - Appel, C. A1 - Prehal, C. A1 - Menzel, A. A1 - Guizar-Sicairos, M. A1 - Smales, Glen J. A1 - Pauw, Brian Richard A1 - Gasteiger, H. A. A1 - Gubler, L. A1 - Büchi, F. N. A1 - Eller, J. T1 - Impact of Microporous Layer Composition on the Water Content in the Membrane Electrode Assembly of Polymer Electrolyte Fuel Cells N2 - Polymer electrolyte fuel cells are paramount for future emission-free mobility. One of the vital challenges for prospering commercialization of PEFCs is water management in the cells. A microporous layer (MPL) is typically positioned between the gas Diffusion layer (GDL) and the catalyst layer (CL) to boost the cell performance and facilitate water management. In this study, three different MPLs were investigated, namely, carbon black-based MPLs with different PTFE binder contents (20 wt % PTFE as a base case and 40 wt % PTFE), as well as perforated MPLs with micron-sized pores coated on the same GDL- Substrate (Freudenberg H14). The water content in the membrane, catalyst layers (CL), and MPLs was explored using operando scanning small- and wide-angle X-ray scattering (S/WAXS). At Tcell = 80 °C, relative humidity = 100%, pabs = 3 bar, the MPL with larger pores exhibits slightly higher performance than the base case, while a considerably lower cathode CL and MPL saturation levels were observed for the MPL. In contrast, the MPL with higher amounts of PTFE binder shows lower performance than the base case, with considerably higher cathode CL and MPL saturation levels. 3D representations of how the pores could be filled in the cathode CLs were obtained from operando SAXS profiles using representative structure modeling for the different materials and operating conditions. KW - Polymer electrolyte fuel cell KW - Catalyst layer saturation KW - Microporous layer saturation KW - Membrane hydration KW - Small and wide-angle scattering KW - MOUSE KW - SAXS KW - X-ray scattering KW - Energy storage materials PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-656691 DO - https://doi.org/10.1021/acsami.5c22540 SN - 1944-8244 SP - 1 EP - 17 PB - American Chemical Society (ACS) AN - OPUS4-65669 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Laboratory x-ray scattering instruments as agile test-beds towards holistic experimentation N2 - Laboratory sources offer a unique advantage compared to synchrotron sources, largely in terms of freedom of operation. This freedom from user obligations, technology and software stacks and legacy decisions make the laboratory a very flexible place to develop and explore new ideas. The unparalleled availability furthermore allows for iterative improvement of instrumentation, sample environments and measurement methodologies to maximise the quality of the data obtained. This talk will highlight the use of the laboratory as an agile test-bed and development space, by giving examples of some complete and incomplete investigations undertaken in our laboratory over the last years. Furthermore, it will introduce the concept of holistic experimentation, where the laboratory provides broad-ranging support for materials science investigations. This means that we assist in the experimental preparation, perform the measurements, correction and analysis, and follow-up with assistance in interpretation of our analyses in light of the results from other techniques applied to the investigation. T2 - Invited talk at Diamond Light Source CY - Didcot, UK DA - 22.05.2024 KW - X-ray scattering KW - Methodology development KW - Laboratory management KW - Holistic experimentation KW - Laboratory automation KW - Nanostructural analysis PY - 2024 AN - OPUS4-60582 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Glimpses of the Future : Oh my god it’s full of metadata! N2 - In this talk, the importance of metadata is underscored by real-world examples. Metadata is essential to alleviating the reproducibility crises in science. This imples that a wide range of metadata must be collected, with a heavy emphasis on the automated collection of such metadata. This must subsequently be organized in an intelligible, archival structure, when possible with units and uncertainties. Such metadata can aid in improving the usage efficiency of instrumentation, as is demonstrated on the MOUSE instrument. This metadata can now be used to connect the various aspects of the holistic experimental procedure to gain better insights on the materials structure. A second example shows the extraction and organization of such metadata from an automated materials development platform, collected during the synthesis of 1200 samples. These metadata from the synthesis can then be linked to the results from the analysis of these samples, to find direct correlations between the synthesis parameters and the final structure of the materials. T2 - Helmholtz Incubator Summer Academy - Next Level Data Science CY - Online meeting DA - 18.09.2023 KW - Metadata KW - Lab automation KW - Data provenance KW - High-throughput KW - Correlative analysis KW - MOUSE KW - X-ray scattering KW - Robotics PY - 2023 AN - OPUS4-58463 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - Chasing perfection: A holistic approach to materials science scattering experiments N2 - The materials scientists we work with do not want (or need) to learn the ways of the scatterer; they are primarily interested in obtaining trustworthy answers. In particular, they need structural understanding in light of the wider framework of their experiment(s). Our interest, therefore, lies in helping them attain this this interconnected understanding, while using such investigations to further hone our methodology to approximate perfection. While perfection is by definition an unattainable goal, we have spent the last 15+ years exploring and expanding on many of its constituent aspects (often together with likeminded people) [1]. These aspects include: - developing various visualization and simulation tools, - deconstructing data corrections and uncertainty estimation, - advancing analysis methods, - quantifying questions on traceability, documentation, - reproducible automation of synthesis-, measurement- and data pipelines, - data visualization, exploration and education, - and many more… T2 - XIX International Small Angle Scattering Conference CY - Taipei, Taiwan DA - 04.11.2024 KW - Methodology KW - X-ray scattering KW - Data quality KW - Data provenance KW - Data stewardship KW - Lab automation KW - Perfection PY - 2024 AN - OPUS4-61625 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauw, Brian Richard T1 - A holistic experiment chain for scattering-powered materials science investigations N2 - In our (dramatically understaffed) X-ray scattering laboratory, developing a systematic, holistic methodology1 let us provide scattering and diffraction information for more than 2100 samples for 200+ projects led by 120+ collaborators over the last five years. Combined with universal, automat-ed data correction pipelines, as well as our analysis and simulation software, this led to more than 40 papers2 in the last 5 years with just over 2 full-time staff members. While this approach greatly improved the consistency of the results, the consistency of the samples and sample series provided by the users was less reliable nor necessarily reproducible. To address this issue, we built an EPICS-controlled, modular synthesis platform to add to our laboratory. To date, this has prepared over 1200 additional (Metal-Organic Framework) samples for us to meas-ure, analyse and catalogue. By virtue of the automation, the synthesis of these samples is automat-ically documented in excruciating detail, preparing them for upload and exploitation in large-scale materials databases alongside the morphological results obtained from the automated X-ray scat-tering analysis. Having developed these proof-of-concepts, we find that the consistency of results are greatly im-proved by virtue of their reproducibility, hopefully adding to the reliability of the scientific findings as well. Additionally, the nature of the experiments has changed greatly, with much more emphasis on preparation and careful planning. This talk will discuss the advantages and disadvantages of this highly integrated approach and will touch upon upcoming developments. T2 - canSAS-XIII CY - Grenoble, France DA - 16.10.2023 KW - Methodology KW - Lab automation KW - X-ray scattering KW - Automated synthesis KW - Data stewardship KW - Holistic experimental procedures KW - Scicat PY - 2023 AN - OPUS4-58643 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Miyata, Ayana A1 - Tokuda, Shun A1 - Kuzumoto, Mako A1 - Lee, Guan-Sian A1 - Yamashita, Masataka A1 - Nishiguchi, Taichi A1 - Negoro, Masaki A1 - Pauw, Brian Richard A1 - Chan, Yi-Tsu A1 - Kanamori, Kazuyoshi A1 - Urayama, Kenji A1 - Sugimoto, Kunihisa A1 - Furukawa, Shuhei T1 - One-Dimensional van der Waals Porous Fibrils Assembled from Metal–Organic Polyhedra N2 - Supramolecular systems exhibit collective functions that emerge from the hierarchical assembly of individual molecular building blocks. Metal−organic polyhedra (MOPs) are a class of functional supramolecular architectures with well-defined molecular geometry and an intrinsic cavity. In recent years, considerable progress has been made in assembling MOPs into extended networks to create porous solids. However, most reported MOP assemblies are limited to three-dimensional networks, which, owing to their high-dimensional connectivity, hinder effective stress dissipation and render them brittle under mechanical stress. Here, we report the one-dimensional (1D) self-assembly of MOPs into supramolecular polymeric aerogels that combine permanent microporosity with exceptional mechanical flexibility. The reaction between amino acid-functionalized naphthalenediimide (NDI) linkers and copper salts led to the synthesis of octahedral copper-based MOPs, followed by their spontaneous self-assembly to form supramolecular gels. The corresponding aerogels converted from the gels possessed uniform 1D fibrillar networks (14.8 ± 2.2 nm in width) with intrinsic microporosity derived from individual MOP cavities. The aerogel endured 87% compressive strain without fracture, demonstrating distinct ductility. Furthermore, these fibrils in the supramolecular gels were converted to crystals after 2 weeks. Single-crystal X-ray diffraction revealed that MOPs are arranged via face-to-face interaction between octahedral MOPs to form a 1D helical chain structure. An analysis of the self-assembly process using Hansen solubility parameters unveiled that solvent conditions with high polarity and low dispersion interaction drive the formation of anisotropic assemblies. This work provides a new strategy for tailoring the mechanical properties of supramolecular materials through dimensional control of their assemblies. KW - Aerogels KW - Crystals KW - Metal organic frameworks KW - Nanofibers KW - Solvents KW - X-ray scattering KW - SAXS KW - Nanostructure KW - Small-angle X-ray scattering PY - 2026 DO - https://doi.org/10.1021/jacs.5c21654 SN - 0002-7863 SP - 1 EP - 13 PB - American Chemical Society (ACS) AN - OPUS4-65776 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -