TY - JOUR A1 - McGonigle, Rebecca A1 - Glasgow, Jodie A1 - Houston, Catriona A1 - Cameron, Iain A1 - Homann, Christian A1 - Black, Dominic J. A1 - Pal, Robert A1 - MacKenzie, Lewis E. ED - MacKenzie, Lewis E. T1 - Autoclave reactor synthesis of upconversion nanoparticles, unreported variables, and safety considerations N2 - Autoclave reactors are widely used across chemical and biological sciences, including for the synthesis of upconversion nanoparticles (UCNPs) and other nanomaterials. Yet, the details of how autoclave reactors are used in such synthesis are rarely reported in the literature, leaving several key synthesis variables widely unreported and thereby hampering experimental reproducibility. In this perspective, we discuss the safety considerations of autoclave reactors and note that autoclaves should only be used if they are (a) purchased from reputable suppliers/manufacturers and (b) have been certified compliant with relevant safety standards. Ultimately, using unsuitable autoclave equipment can pose a severe physical hazard and may breach legal safety requirements. In addition, we highlight several parameters in autoclave synthesis that should be reported as standard to maximise the reproducibility of autoclave synthesis experiments across materials and chemistry research. We encourage users of autoclave synthesis vessels to: (1) adopt high-safety autoclaves and (2) report the many experimental variables involved to enhance experimental reproducibility. KW - Reference material KW - Nano KW - Particle KW - Shell KW - Fluorescence KW - Lifetime KW - Decay kinetics KW - Synthesis KW - Quality assurance KW - Method KW - Energy transfer KW - Upconversion KW - Autoclave synthesis KW - Data comparability PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625672 DO - https://doi.org/10.1038/s42004-025-01415-3 VL - 8 IS - 1 SP - 1 EP - 7 PB - Springer Science and Business Media LLC AN - OPUS4-62567 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oskolkova, Tatiana O. A1 - Matiushkina, Anna A1 - Borodina, Lyubov' N. A1 - Smirnova, Ekaterina S. A1 - Dadadzhanova, Antonina I. A1 - Sewid, Fayza A. A1 - Veniaminov, Andrey V. A1 - Moiseeva, Ekaterina O. A1 - Orlova, Anna O. T1 - FRET‐Amplified Singlet Oxygen Generation by Nanocomposites Comprising Ternary AgInS2/ZnS Quantum Dots and Molecular Photosensitizers N2 - Antibacterial photodynamic therapy (a‐PDT) has emerged as a promising non‐invasive therapeutic modality that utilizes the combination of a photosensitive agent, molecular oxygen, and excitation light to generate reactive oxygen species (ROS), demonstrating remarkable activity against multidrug‐resistant bacterial infections. However, the effective use of conventional photosensitizers is significantly limited by a number of their shortcomings, namely, poor water solubility and low selectivity. Herein, we present a novel biocompatible water‐soluble nanocomposite based on hydrophobic tetraphenylporphyrin (TPP) molecules and hydrophilic ternary AgInS2/ZnS quantum dots incorporated into a chitosan matrix as an improved photosensitizer for a‐PDT. We demonstrated that TPP molecules could be successfully transferred into chitosan solution while remaining primarily in the form of monomers, which are capable of singlet oxygen generation. We performed a detailed analysis of the Förster resonance energy transfer (FRET) between quantum dots and TPP molecules within the nanocomposite and proposed the mechanism of the singlet oxygen efficiency enhancement via FRET. KW - Nano KW - Particle KW - Quantum dot KW - Fluorescence KW - Synthesis KW - Optical spectroscopy KW - Energy transfer KW - Quality assurance KW - Lifetime KW - Quantum yield PY - 2024 DO - https://doi.org/10.1002/cnma.202300469 SN - 2199-692X VL - 10 IS - 3 SP - 1 EP - 11 PB - Wiley AN - OPUS4-59728 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Meng, M. A1 - Zhang, R. A1 - Fa, X. A1 - Yang, J. A1 - Cheng, Z. A1 - Ansari, A. A. A1 - Ou, Jun A1 - Würth, Christian A1 - Resch-Genger, Ute T1 - Preparation of core–shell structured NaYF4:Yb3+/ Tm3+@NaYF4:Yb3+/Er3+ nanoparticles with high sensitivity, low resolution and good reliability and application of their fluorescence temperature properties N2 - A series of NaYF4:Yb3+/Tm3+@NaYF4:Yb3+/Er3+ nanoparticles doped with Tm3+ and Er3+ were successfully prepared by the solvothermal method. Under 980 nm laser excitation, intense upconversion emission peaks of Tm3+ and Er3+ were observed for all samples. By doping Tm3+ and Er3+ with core–shell partitioning, not only a significant increase in fluorescence intensity could be achieved, but also simultaneous temperature measurements on multiple thermocouple energy levels could be realised. In addition, the temperature sensing performance of different thermocouple energy levels was also investigated, and it was found that the 3 F3 → 3 H6 and 1 G4 → 3 F4 thermocouple energy level pairs of Tm3+ were the best, with maximum absolute sensitivity and maximum relative sensitivity of up to 0.0250 K−1 and 2.155% K−1 respectively, higher than the sensitivity of other thermocouple energy levels. It has a temperature resolution of less than 0.0139 K, which is lower than that of most materials available today. By using this material as a probe to build a fiber optic temperature sensor platform, it was found to have reliable temperature measurement performance. KW - Flourescence KW - Optical probe KW - Sensor KW - Dye KW - Temperature KW - Nano KW - Particle KW - Upconversion KW - Lanthanide KW - Qantum yield KW - Quality assurance KW - Monitoring KW - Infrastructure PY - 2022 DO - https://doi.org/10.1039/d1ce01729b VL - 24 IS - 9 SP - 1752 EP - 1763 PB - RSC Publishing AN - OPUS4-54416 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Design, characterization, and application of fluorescent sensor particles N2 - pH and oxygen are amongst the most important and frequently measured analytes in the life and material sciences, indicating, e.g., diseases and corrosion processes. This includes the optical monitoring of pH in living cells for studying cellular internalization pathways, such as phagocytosis, endocytosis, and receptor ligand internalization with the aid of molecular and nanoscale fluorescent sensors. Nanoparticle (NP)-based sensors, that are labeled or stained with a multitude of sensor dyes, have several advantages as compare to conventional molecular probes like enhanced brightness, i.e., amplified signals, ease of designing ratiometric systems by combining analyte sensitive and inert reference dyes, and increased photostability. Moreover, this can enable the use of hydrophobic dyes in aqueous environments. Versatile templates and carriers for the fabrication of nanosensors by the staining and/or labelling with different fluorophores and sensor molecules or surface functionalized NP like silica (SiO2-NP) and polystyrene (PS-NP) particles provide. Here we present the design of a versatile platform of color emissive nanosensors and stimuli-responsive microparticles for the measurement of pH, oxygen, and other targets utilizing both types of matrices and sets of spectrally distinguishable sensor and reference dyes and their characterization and demonstrate the applicability of representative sensor particle for cellular studies. T2 - Vortrag bei dem Projekttreffen MicraGen CY - Copenhagen, Denmark DA - 18.08.2022 KW - Dye KW - Luminescence KW - Quantitative spectroscopy KW - Photophysics KW - Quality assurance KW - Nano KW - Particle KW - Quantum yield KW - Lifetime KW - Standard KW - Integrating sphere spectroscopy KW - Sensor KW - pH KW - Oxygen KW - Microfluidics KW - Cancer KW - Cell KW - Life sciences PY - 2022 AN - OPUS4-57049 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tavernaro, Isabella T1 - Amorphous, fluorescent silica particles for bioimaging applications N2 - Nowadays amorphous silica nanoparticles (SiO2 NP) are one of the most abundant engineered nanomaterials, with an annual production of hundreds of thousands of tons, that are used in a broad field of industrial products and processes. Since SiO2 NP are highly stable and easily produced on a large scale at low cost, they are widely employed as fillers for rubbers and composites, absorbents, catalysts, advanced coating additives as well as plant growth agents in agriculture, anti-caking agents in food products, or as carrier material in cosmetic industry. Moreover, they are promising candidates for colloidal scaffolds in biomedical applications like bioimaging, sensing or controlled drug delivery. SiO2 NP modified with luminescent chromophores have several advantages as compared to conventional molecular probes like enhanced brightness, ease of designing ratiometric systems, and increased photostability. Here we present our work on multicolored SiO2 NP for imaging and sensing applications. T2 - FUNGLASS Workshop CY - Berlin, Germany DA - 06.03.2024 KW - Sensors KW - Nano KW - Particles KW - Silica KW - Luminescence KW - Fluorescence KW - Quality assurance KW - Method KW - Synthesis KW - Dye KW - pH KW - Surface analysis PY - 2024 AN - OPUS4-62167 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Geißler, Daniel A1 - Wegner, Karl David A1 - Fischer, C. A1 - Resch-Genger, Ute T1 - Exploring Simple Particle-Based Signal Amplification Strategies in a Heterogeneous Sandwich Immunoassay with Optical Detection N2 - Heterogeneous sandwich immunoassays are widely used for biomarker detection in bioanalysis and medical diagnostics. The high analyte sensitivity of the current “gold standard” enzyme-linked immunosorbent assay (ELISA) originates from the signal-generating enzymatic amplification step, yielding a high number of optically detectable reporter molecules. For future point-of-care testing (POCT) and point-of-need applications, there is an increasing interest in more simple detection strategies that circumvent time-consuming and temperature-dependent enzymatic reactions. A common concept to aim for detection limits comparable to those of enzymatic amplification reactions is the usage of polymer nanoparticles (NP) stained with a large number of chromophores. We explored different simple NP-based signal amplification strategies for heterogeneous sandwich immunoassays that rely on an extraction-triggered release step of different types of optically detectable reporters. Therefore, streptavidinfunctionalized polystyrene particles (PSP) are utilized as carriers for (i) the fluorescent dye coumarin 153 (C153) and (ii) hemin (hem) molecules catalyzing the luminol reaction enabling chemiluminescence (CL) detection. Additionally, (iii) NP labeling with hemin-based microperoxidase MP11 was assessed. For each amplification approach, the PSP was first systematically optimized regarding size, loading concentration, and surface chemistry. Then, for an immunoassay for the inflammation marker C- eactive protein (CRP), the analyte sensitivity achievable with optimized PSP ystems was compared with the established ELISA concept for photometric and CL detection. Careful optimization led to a limit of detection (LOD) of 0.1 ng/mL for MP11-labeled PSP and CL detection, performing similarly well to a photometric ELISA (0.13 ng/mL), which demonstrates the huge potential of our novel assay concept. KW - Nanoparticle KW - Fluorescence KW - Immunoassay KW - Quality assurance KW - Antibody KW - Polymer KW - Dye KW - Signal enhancement KW - CRP KW - Biosensing PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597853 DO - https://doi.org/10.1021/acs.analchem.3c03691 SN - 1520-6882 VL - 96 IS - 13 SP - 5078 EP - 5085 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-59785 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Resch-Genger, Ute A1 - Abram, Sarah-Luise A1 - Tavernaro, Isabella A1 - Zou, Shan A1 - Johnston, Linda T1 - Behind the Paper: Nanoscale Reference and Test Materials for the Validation of Characterization Methods for Engineered Nanomaterials – Current State, Limitations and Needs N2 - Engineered nanomaterials (NMs) of different material composition, morphology, and surface chemistry are widely used in material and life sciences. For NM quality control and risk assessment, NM key properties must be characterized with validated methods, requiring reference materials (RMs). KW - Engineered Nanomaterials KW - Nanoscale reference materials KW - Interlaboratory comparisons KW - Traceability KW - Standardization and Regulation KW - Nano KW - Particle KW - Quality assurance KW - Surface chemistry PY - 2025 UR - https://communities.springernature.com/posts/nanoscale-reference-and-test-materials-for-the-validation-of-characterization-methods-for-engineered-nanomaterials-current-state-limitations-and-needs SP - 1 EP - 3 PB - Springer Nature CY - Online AN - OPUS4-62572 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Haroun, A. A. A. A1 - Derbala, H. A. A1 - Bassioni, G. A1 - Resch-Genger, Ute A1 - Shafik, E. S. A1 - Hassan, A. M. A. T1 - N-aminophthalimide as a novel UV-stabilizer to promote physico-mechanical properties of highdensity polyethylene (HDPE) N2 - This study aimed to evaluate the efficacy of Naminophthalimide (NAP) as a novel UV-stabilizer for highdensity polyethylene (HDPE) in improving its physicomechanical properties under UV exposure. NAP was synthesized by interaction between phthalimide and hydrazine hydrate. It was incorporated into HDPE with different weight ratios (1, 1.5, 2, and 3%), and its performancewas compared with Hostavin as a traditional UV stabilizer. The HDPE composites were exposed to UV irradiation for different periods (7 and 14 days) to evaluate their photodegradation behavior. Tensile strength, elongation at break were assessed before and after UV exposure. Also, oxidation induction time (OIT), melt flow rate (MFR), Vicat softening temperature were evaluated. Hostavin incorporation reduced tensile strength from 22.36 to 20.62MPa at higher concentrations. It has been found that 3% Hostavin, significantly improved elongation at break, increasing from 423% to 1,170%, suggesting enhanced flexibility. In contrast, NAP increased tensile strength to 22.9MPa and moderately enhanced elongation but slightly declined at 3%due to potential over-stabilization. Under UV exposure, retained tensile strength and elongation was improved with stabilizer content, which increasing tensile strength retention. The HDPE that containing NAP showed enhanced UV resistance and superior retention of mechanical properties compared to Hostavin. KW - Polymer KW - Advanced materials KW - Quality assurance KW - Stabilizer KW - Synthesis KW - Physico-mechanical properties PY - 2025 DO - https://doi.org/10.1515/polyeng-2024-0262 SN - 2191-0340 SP - 1 EP - 8 PB - De Gruyter CY - Berlin AN - OPUS4-63534 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Reliable Photoluminescence Quantum Yields – New Reference Materials and Interlaboratory Comparisons N2 - The rational design and choice of molecular and nanoscale reporters, the comparison of different emitter classes, and photophysical and mechanistic studies require quantitative photoluminescence measurements and the reliable determination of the key performance parameter photoluminescence quantum yield (QY), i.e., the number of emitted per absorbed photons. This is of special importance for all photoluminescence applications in the life and material sciences in the UV/vis/NIR/SWIR. To improve the reliability and comparability of photoluminescence and QY measurements across laboratories, pitfalls, achievable uncertainties, and material-specific effects related to certain emitter classes must be explored. Also, suitable protocols and reference materials are needed which have been validated in interlaboratory comparisons for different wavelength regions and transparent and scattering luminophores.[1] Based on absolute and relative photoluminescence measurements of functional dyes and luminescent nanomaterials, reliable methods for determining QY of transparent and scattering luminophores, nonlinear emitters, and solid luminescent nanomaterials have been developed.[1-4] Thereby, material- and method-related uncertainties of relative and absolute QY measurements and achievable uncertainties could be quantified for linear and nonlinear UV/vis/NIR/SWIR emitters and lately for also luminescent and scattering materials and solid phoshors. In this context, we present the development and certification of a first set of UV/vis/NIR quantum yield standards with a complete uncertainty budget,[5] which present simple tools for a better comparability of QY measurements. In addition, a first interlaboratory comparison of absolute QY measurements of solid and scattering LED converter materials with integrating sphere spectroscopy has been performed.[5] The outcome of this study is presented, thereby addressing common pitfalls and measurement uncertainties and providing recommendations for the performance of reliable QY measurements of linear and non-linear emitters in transparent, scattering, and solid samples. T2 - Anakon 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Quality assurance KW - Reference material KW - Method KW - Fluorescence KW - Quantum yield KW - Absolute KW - Integrating sphere spectroscopy KW - Interlaboratory comparison KW - Dye KW - Film KW - Nano KW - Particle KW - Scattering KW - Uncertainty KW - LED converter PY - 2025 AN - OPUS4-62792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schweizer, S. T1 - Interlaboratory comparison on absolute PL quantum yield measurements of scattering luminescent materials N2 - Optical measurements of scattering luminescent materials dispersed in liquid and solid matrices and luminescent powders play an important role in fundamental research and industry. Typical examples are luminescent nano- and microparticles and phosphors of different composition in different matrices or incorporated into ceramics with applications in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. The key parameter for the performance of these materials is the photoluminescence quantum yield QY, i.e., the number of emitted photons per number of absorbed photons. QY of transparent luminophore solutions can be determined relatively to a fluorescence quantum yield standard of known QY. Such standards are meanwhile available as certified reference materials.[1] The determination of QY of scattering liquid and solid samples like dispersions of luminescent nanoparticles, solid phosphors, and optoceramics requires, however, absolute measurements with an integrating sphere setup. Although the importance of reliable absolute QY measurements has been recognized, no interlaboratory comparisons (ILCs) on measurement uncertainties and the identification of typical sources of uncertainty have been yet reported. Also, no scattering reference materials with known QY are available. We present here the results of a first ILC of 3 laboratories from academia and industry performed to identify and quantify sources of uncertainty of absolute QY measurements of scattering samples. Thereby, two types of commercial stand-alone integrating sphere setups with different illumination and detection geometries were utilized for measuring QY of transparent and scattering dye solutions and solid phosphors. As representative and industrially relevant solid and scattering samples, YAG:Ce optoceramics of varying surface roughness were chosen, applied, e.g., as converter materials for blue light emitting diodes. Special emphasis was dedicated to the influence of the measurement geometry, the optical properties of the blank, utilized to determine the number of photons of the incident excitation light absorbed by the sample, and the sample-specific surface roughness. While matching QY values could be obtained for transparent dye solutions and scattering dispersions, here using a blank with scattering properties closely matching those of the sample, QY measurements of optoceramic samples with different blanks revealed substantial differences, with the blank's optical properties accounting for measurement uncertainties of more than 20 %. Based upon the ILC results, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder which reveals a near-Lambertian light scattering behavior, yielding a homogeneous light distribution within the integrating sphere. T2 - 8th IWASOM CY - Gdánsk, Poland DA - 07.07.2024 KW - Nano KW - Particle KW - Fluorescence KW - Quantum yield KW - Method KW - Sensor KW - Film KW - Absolute quantum yield KW - Scattering KW - YAG:Ce KW - Quality assurance KW - Lanthanide KW - Upconverter KW - LED KW - Uncertainty KW - Standardization KW - Reference material PY - 2024 AN - OPUS4-62100 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -