TY - CONF A1 - Ruehle, Bastian T1 - Workflow generation, management, and semantic description for Self-Driving Labs N2 - The software backend that controls the robotic hardware and runs the synthesis workflows is a very important component of any Self-Driving Lab (SDL). On the one hand, it has to deal with orchestrating and managing complex and task-specific hardware through low-level communication protocols and plan and use the available resources as efficiently as possible while executing (parallelized) workflows, on the other hand, it is the interface the users use to communicate with this highly complex platform, and as such, it needs to be as helpful and user-friendly as possible. This includes the AI-aided experimental design in which the system helps the user to decide which experiment to run next, providing automated data analysis from characterization measurements, and offering easy to understand tools and graphical user interfaces for generating the workflows that are executed on the platform. Lastly, the specificity of the workflows and their dependence on the hardware and software of the SDLs necessitates a common description or ontology for making them easily interchangeable and interoperable between different platforms and labs. In this contribution, we present several key aspects of “Minerva-OS”, the central backend that orchestrates the syntheses workflows of our SDL for Nano- and Advanced Materials Syntheses [1]. One key feature is the resource management or “traffic control” for scheduling and executing parallel reactions in a multi-threaded environment. Another is the interface with data analysis algorithms from in-line, at-line, and off-line measurements. Here, we will give examples of how automatic image segmentation of electron microscopy images with the help of AI [2] can be used for reducing the “data analysis bottleneck” from an off-line measurement. We will also discuss, compare, and show benchmarks of various machine learning (ML) algorithms that are currently implemented in the backend and can be used for ML-guided, closed-loop material optimization in our SDL. Lastly, we will show our recent efforts [3] in making the workflow generation on SDLs more user-friendly by using large language models to generate executable workflows automatically from synthesis procedures given in natural language and user-friendly graphical user interfaces based on node editors that also allow for knowledge graph extraction from the workflows. In this context, we are currently also working on an ontology for representing the process steps of the workflows, which will greatly facilitate the semantic description and interoperability of workflows between different SDL hardware and software platforms. T2 - Accelerate 2025 CY - Toronto, Canada DA - 11.08.2025 KW - Nanomaterials KW - Advanced Materials KW - Workflows KW - Machine Learning KW - SDL PY - 2025 AN - OPUS4-63936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ruehle, Bastian T1 - Nano- and Advanced Materials Synthesis in a Self-Driving Lab (SDL) N2 - Nano- and advanced materials have been recognized as a key enabling technology of the 21st century, due to their high potential of driving innovations in new clean energy technologies, sustainable manufacturing by substitution of critical raw materials and replacement of hazardous substances, breakthroughs in energy conversion and storage, improvement of the environmental performance of products and processes, and facilitation of circularity. Consequently, improving tools that enhance the development and optimization cycle of nano- and advanced materials is crucial. In this contribution, we present our Self-Driving Lab (SDL) for Nano and Advanced Materials [1], that integrates robotics for batched autonomous synthesis – from molecular precursors to fully purified nanomaterials – with automated characterization and data analysis, for a complete and reliable nanomaterial synthesis workflow. By fully automating these three process steps for seven different materials from five representative, completely different classes of nano- and advanced materials (metal, metal oxide, silica, metal organic framework, and core–shell particles) that follow different reaction mechanisms, we demonstrate the great versatility and flexibility of the platform. The system also exhibits high modularity and adaptability in terms of reaction scales and incorporates in-line characterization measurement of hydrodynamic diameter, zeta potential, and optical properties (absorbance, fluorescence) of the nanomaterials. We discuss the excellent reproducibility of the various materials synthesized on the platform in terms of particle size and size distribution, and the adaptability and modularity that allows access to a diverse set of nanomaterial classes. These features underscore the SDL’s potential as a transformative tool for advancing and accelerating the development of nano- and advanced materials, offering solutions for a sustainable and environmentally responsible future. T2 - Accelerate 2025 CY - Toronto, Canada DA - 11.08.2025 KW - Nanomaterials KW - Advanced Materials KW - Automation KW - SDL KW - MAP PY - 2025 AN - OPUS4-63935 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ruehle, Bastian T1 - Nano- and Advanced Materials Synthesis in a Self-Driving Lab (SDL) N2 - Nano- and advanced materials have been recognized as a key enabling technology of the 21st century, due to their high potential of driving innovations in new clean energy technologies, sustainable manufacturing by substitution of critical raw materials and replacement of hazardous substances, breakthroughs in energy conversion and storage, improvement of the environmental performance of products and processes, and facilitation of circularity. Consequently, improving tools that enhance the development and optimization cycle of nano- and advanced materials is crucial. In this contribution, we present our Self-Driving Lab (SDL) for Nano and Advanced Materials [1], that integrates robotics for batched autonomous synthesis – from molecular precursors to fully purified nanomaterials – with automated characterization and data analysis, for a complete and reliable nanomaterial synthesis workflow. By fully automating these three process steps for seven different materials from five representative, completely different classes of nano- and advanced materials (metal, metal oxide, silica, metal organic framework, and core–shell particles) that follow different reaction mechanisms, we demonstrate the great versatility and flexibility of the platform. The system also exhibits high modularity and adaptability in terms of reaction scales and incorporates in-line characterization measurement of hydrodynamic diameter, zeta potential, and optical properties (absorbance, fluorescence) of the nanomaterials. We discuss the excellent reproducibility of the various materials synthesized on the platform in terms of particle size and size distribution, and the adaptability and modularity that allows access to a diverse set of nanomaterial classes. These features underscore the SDL’s potential as a transformative tool for advancing and accelerating the development of nano- and advanced materials, offering solutions for a sustainable and environmentally responsible future. T2 - Accelerate 2025 CY - Toronto, Canada DA - 11.08.2025 KW - Nanomaterials KW - Advanced Materials KW - Automation KW - SDL KW - MAP PY - 2025 AN - OPUS4-63934 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vermeeren, Sarah A1 - Witzler, Markus A1 - Makarow, Ramona A1 - Engelhard, Carsten A1 - Kaul, Peter T1 - Multivariate evaluation method for the detection of pest infestations on plants via VOC analysis using gas chromatography mass spectrometry N2 - Volatile organic compounds (VOCs) play an important role in the defense against pest infestations on plants. The analysis of these VOCs using gas chromatography mass spectrometry (GC-MS) enables the detection of pests by analyzing the VOC composition (VOC profiles) for specific patterns and markers. The analysis of such complex datasets with high biovariability poses a particular challenge. For this reason, a multivariate evaluation method based on a self-written Python script, using principal component analysis (PCA) and linear discriminant analysis (LDA), was developed and tested for functionality using a dataset, which has been evaluated manually and has identified five specific markers (2,4-dimethyl-1-heptene, 3-carene, alpha-longipinene, cyclosativene, and copaene) for Anoplophora glabripennis (ALB) infestation on Acer trees. The results obtained in the present study did not only match the manually evaluated results, but lead to further insight into the dataset. Another sesquiterpene which is assumed to be alpha-zingiberene was identified as an ALB specific marker in addition to 2,4-dimethyl-1-heptene and 3-carene. Furthermore, the European native beetle species goat moth Cossus cossus (CC) and poplar long-horned beetle Saperda carcharias (SC) were also analyzed for their VOCs to differentiate ALB specific VOC from other pest infestations. This comparison lead to the conclusion that the compounds alpha-longipinene, cyclosativene, and copaene are not specific for ALB but for pest infestation in general. It was possible to identify not only specifically produced VOCs, but also differences in concentrations that arise specifically during ALB infestation. Therefore, the evaluation method for the detection of plant pests presented in this study represents a time-saving alternative to conventional non computing methods, which in addition provides more detailed results. KW - Mass Spectrometry KW - Gas Chromatography KW - Volatile organic compounds KW - Pest infestation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639526 DO - https://doi.org/10.1038/s41598-025-11607-5 SN - 2045-2322 VL - 15 IS - 1 SP - 1 EP - 10 PB - Springer Science and Business Media LLC AN - OPUS4-63952 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Braun, Jennifer A1 - Engelhard, Carsten A1 - Kaul, Peter T1 - Optimized fast gas chromatography coupled with proton-transfer-reaction time-of-flight mass spectrometry for the selective near real-time analysis of herbivore-induced plant volatiles N2 - The analysis of herbivore-induced plant volatiles (HIPVs) is essential for understanding plant-environment interactions and defense strategies against herbivores. Proton transfer reaction time-of-flight mass spectrometry (PTR–TOF–MS) is a powerful analytical tool that enables real-time monitoring and quantification of diverse groups of HIPVs. However, the PTR–TOF–MS technique is constrained in its ability to effectively differentiate between isomers. When analyzing complex mixtures of HIPVs, the separation of isomers becomes crucial as major compound classes such as terpenes comprise thousands of isomers. In this study, we present an optimized fast gas chromatography (fastGC) based on a modified version of the commercially available fastGC add-on integrated into a mobile PTR–TOF. The system was optimized for the analysis of emissions from enclosed trunks of Acer platanoides infested by Anoplophora glabripennis (Motschulsky), commonly known as Asian longhorned beetle (ALB). The development of fastGC was primarily focused on the sesquiterpenes α-longipinene, cyclosativene and α-copaene, which serve as strong indicators of ALB infestation. These sesquiterpenes were separated in less than three minutes, with intra-day retention time RSD < 0.6 % and resolutions of 2.6 ± 0.3 and 1.3 ± 0.2. In comparison to the original system, the optimized fastGC demonstrates more than tripled sesquiterpene resolution, twice the sensitivity relative to direct inlet mode, and an approximately 10 % reduction in total analysis time. The optimized fastGC–PTR–TOF allows for near real-time analysis of complex mixtures of biogenic VOCs, making it a powerful tool for environmental monitoring, integrated pest management, and forest protection. KW - Mass Spectrometry KW - PTR-TOF-MS KW - Gas Chromatography KW - Herbivore-induced plant volatiles KW - Sesquiterpenes PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639513 DO - https://doi.org/10.1016/j.chroma.2025.466236 SN - 0021-9673 VL - 1759 SP - 1 EP - 16 PB - Elsevier B.V. AN - OPUS4-63951 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider, Rudolf T1 - Bestimmung von Spurenstoffen im (Roh-)Abwasser mittels ELISA N2 - Der Vortrag behandelt die Bestimmung von Spurenstoffen im Rohabwasser mithilfe von ELISA (Enzyme-Linked Immunosorbent Assay), einer immunanalytischen Methode, die sich durch hohe Sensitivität und Eignung für Hochdurchsatzanalysen auszeichnet. Im Rahmen der Projekte MARKERIA I & II wurden verschiedene anthropogene Marker wie Koffein, Carbamazepin, Diclofenac, Bisphenol A und Hormone wie Östron untersucht, um deren Eignung für die Abwassersurveillance zu bewerten. Die Ergebnisse zeigen, dass einige Substanzen wie Carbamazepin stabile Konzentrationen aufweisen und sich gut als Marker eignen, während andere wie Koffein starke Schwankungen zeigen. Einige Marker wie Isolithocholsäure werden zwar in hohen Konzentrationen gefunden, zeigen aber methodische Herausforderungen wie instabile Assays. Die Studie hebt hervor, dass es Hotspots mit erhöhten Konzentrationen gibt, aber insgesamt eine relativ geringe Variabilität zwischen verschiedenen Rohabwässern besteht. Zukünftige Entwicklungen sollen sich auf die Verbesserung von Antikörpern, die Entwicklung tragbarer Vor-Ort-Analysemethoden und die Standardisierung immunanalytischer Verfahren konzentrieren. T2 - AMELAG-Colloquium "Spurenstoffe im (Ab-)Wasser" CY - Online meeting DA - 20.06.2025 KW - Antikörper KW - Schnelltests KW - Abwasser KW - ELISA PY - 2025 AN - OPUS4-63500 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chen, Xinyue A1 - Dong, Ximan A1 - Zhang, Chuyan A1 - Zhu, Meng A1 - Ahmed, Essraa A1 - Krishnamurthy, Giridharan A1 - Rouzbahani, Rozita A1 - Pobedinskas, Paulius A1 - Gauquelin, Nicolas A1 - Jannis, Daen A1 - Kaur, Kawaljit A1 - Hafez, Aly Mohamed Elsayed A1 - Thiel, Felix A1 - Bornemann, Rainer A1 - Engelhard, Carsten A1 - Schönherr, Holger A1 - Verbeeck, Johan A1 - Haenen, Ken A1 - Jiang, Xin A1 - Yang, Nianjun T1 - Interlayer Affected Diamond Electrochemistry N2 - Diamond electrochemistry is primarily influenced by quantities of sp3‐carbon, surface terminations, and crystalline structure. In this work, a new dimension is introduced by investigating the effect of using substrate‐interlayers for diamond growth. Boron and nitrogen co‐doped nanocrystalline diamond (BNDD) films are grown on Si substrate without and with Ti and Ta as interlayers, named BNDD/Si, BNDD/Ti/Si, and BNDD/Ta/Ti/Si, respectively. After detailed characterization using microscopies, spectroscopies, electrochemical techniques, and density functional theory simulations, the relationship of composition, interfacial structure, charge transport, and electrochemical properties of the interface between diamond and metal is investigated. The BNDD/Ta/Ti/Si electrodes exhibit faster electron transfer processes than the other two diamond electrodes. The interlayer thus determines the intrinsic activity and reaction kinetics. The reduction in their barrier widths can be attributed to the formation of TaC, which facilitates carrier tunneling, and simultaneously increases the concentration of electrically active defects. As a case study, the BNDD/Ta/Ti/Si electrode is further employed to assemble a redox‐electrolyte‐based supercapacitor device with enhanced performance. In summary, the study not only sheds light on the intricate relationship between interlayer composition, charge transfer, and electrochemical performance but also demonstrates the potential of tailored interlayer design to unlock new capabilities in diamond‐based electrochemical devices. KW - Nanocrystalline diamond KW - Interfaces KW - Electrochemistry KW - TOF-SIMS KW - SEM PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-621576 DO - https://doi.org/10.1002/smtd.202301774 SN - 2366-9608 VL - 9 IS - 2 SP - 1 EP - 10 PB - Wiley VHC-Verlag CY - Weinheim AN - OPUS4-62157 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Engelhard, Carsten T1 - On ICP-MS with Nanosecond Time Resolution: From Nanoparticles to Microplastics N2 - In this presentation, recent developments in inductively coupled plasma mass spectrometry (ICP-MS) instrumentation for particle characterization in complex mixtures will be reviewed. The current state-of-the-art in single-particle (sp) ICP-MS instrumentation for the detection and characterization of nanoparticles (NP) and microplastics (MPs) as well as remaining challenges will be discussed. While millisecond dwell times were used in the advent of spICP-MS, the use of microsecond dwell times helped to improve nanoparticle data quality and particle size detection limits. We could show that a custom-built high-speed data acquisition unit with microsecond time resolution (μsDAQ) can be used to successfully address issues of split-particle events and particle coincidence, to study the temporal profile of individual ion clouds, and to extend the linear dynamic range by compensating for dead time related count losses. Our latest development is an in-house built data acquisition system with nanosecond time resolution (nanoDAQ). Recording of the SEM signal by the nanoDAQ is performed on the nanosecond time scale with a dwell time of approximately 2 ns and enables detection of gold nanoparticles (AuNP) as small as 7.5 nm with a commercial single quadrupole ICP-MS instrument. [1] Analysis of acquired transient data is based on the temporal distance between detector events and a derived ion event density. It was shown that the inverse logarithm of the distance between detector events is proportional to particle size. Also, the number of detector events per particle can be used to calibrate and determine the particle number concentration (PNC) of a nanoparticle dispersion. In addition to inorganic nanoparticles, first results on the detection of microplastics with spICP-MS will be discussed. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Nano KW - Microplastics KW - Nanoparticle Characterization KW - ICP-MS KW - Instrumentation PY - 2025 AN - OPUS4-63580 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Engelhard, Carsten T1 - From Particles to PFAS: Recent Advances in Plasma-based Instrumentation Development N2 - In this presentation, recent advances in plasma spectrochemistry with hot and cold plasma sources for the direct detection of nanoparticles as well as per- and polyfluoroalkyl substances (PFAS) will be discussed. In the first part, single-particle inductively coupled plasma mass spectrometry (spICP-MS) with an in-house built data acquisition system with nanosecond time resolution (nanoDAQ) will be presented. In the second part, we turn to a cooler plasma source. Specifically, a flowing atmospheric-pressure afterglow source (FAPA) and its application for the direct mass spectrometric analysis of PFAS will be discussed. T2 - 20th European Winter Conference on Plasma Spectrochemistry CY - Berlin, Germany DA - 02.03.2025 KW - ICP-MS KW - Instrumentation KW - Nano KW - Nanoparticle Characterization KW - PFAS PY - 2025 AN - OPUS4-63581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Escobar-Carranza, Cristian C. T1 - On the Detection of Microplastics by Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (FAPA-MS) N2 - Microplastics (MPs) are widespread pollutant particles that can be analyzed using Raman and FTIR spectroscopy combined with optical microscopy. Additionally, pyrolysis (Py) or thermal extraction and desorption (TED) coupled with gas chromatography-mass spectrometry (GC-MS) are used for the characterization of MPs.[1] However, sample throughput is limited due to GC separation. This work presents a feasibility study for the direct, rapid analysis of MPs using high-resolution mass spectrometry and a plasma-based ambient desorption/ionization source (FAPA, flowing atmospheric-pressure afterglow).[2] In earlier work, an in-house built ambient ionization source (modelled after the pin-to-capillary (p2c) FAPA design by Shelley et al. [3]) was coupled to HR-Orbitrap MS and used to characterize different MPs produced in-house from plastic materials including polystyrene (PS), polypropylene (PP), low-density polyethylene (LDPE), and polycarbonate (PC). Simultaneous detection of characteristic ions and particle imaging on a sampling mesh was feasible, with detection limits (LOD) for PS MPs at 311 µm in size and 1.3 mg in mass. Principal component analysis (PCA) was used for particle differentiation. This work presents an improved desorption/ionization approach using higher temperatures for desorption enhancement (approximately 500 °C, achieved with economical and commercially available parts) and a tailored source housing combined with a halo-shaped (h-FAPA) source configuration.[4] The scope was expanded to include MPs from poly(ethylene terephthalate) (PET), poly(methyl methacrylate) (PMMA), and poly(vinyl chloride) (PVC), sized 125–250 µm. Data visualization and interpretation were performed using Kendrick mass defect plots and other multivariate analysis tools. Compared to earlier results, h-FAPA-MS yielded at least 65% higher ion signals for selected ions in all MPs. These ions were detected mainly as protonated species [M+H]+. Higher thermal desorption temperatures aided in detecting all MPs, as the presence of higher molecular weight fragments added specificity to the analysis. Notably, experiments with the h-FAPA source demonstrated lower mass-based LODs for MPs than the p2c-FAPA source (e.g., 14 µg vs 1.3 mg for PS, respectively). T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Mass Spectrometry KW - Plasma KW - FAPA-MS KW - Microplastics PY - 2025 AN - OPUS4-63604 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schütz, Désirée A.-M. T1 - Feasibility Study on the Adsorption of Environmental Contaminants onto Fresh and Aged Microplastics N2 - Microplastics (MPs) refer to plastic particles, fibers, or beads with sizes ranging from 100 nm to 5 mm in size. Their pervasive distribution as environmental contaminants have escalated into a significant global concern. Primary MPs are intentionally produced particles for industrial and commercial applications, such as exfoliants in personal care and cosmetic formulations. In contrast, secondary MPs are generated through the fragmentation and degradation of larger plastic materials, due to environmental weathering processes. [1] Due to their high surface area-to-volume ratio and hydrophobic nature, MPs have the potential to serve as vectors for the accumulation and transport of diverse organic contaminants, including polycyclic aromatic hydrocarbons (PAHs), perfluoroalkyl substances (PFAS), pharmaceuticals and personal care products (PPCPs), as well as trace metals such as silver, cadmium, chromium, and copper. In the environmental, MPs are subject to aging processes driven by factors such as temperature, ultraviolet radiation, oxygen, and chemical interactions with environmental toxins. This aging can induce significant alterations in their physicochemical properties, which, in turn, can affect the adsorption behavior. [2] Classical and alternative analytical methods such as high-performance liquid chromatography (HPLC) and ambient desorption/ionization high-resolution mass spectrometry (ADI-HR-MS) can help to study the adsorption potential. ADI-HR-MS allows rapid sample analysis with minimal preparation, providing results in under a minute, much faster than traditional chromatographic techniques. [3] This study aims to investigate the influence of aging and particle size on the ability of microplastics to act as vectors for environmental contaminants. Microplastics were prepared in-house and subjected to controlled aging conditions for 12, 24, 36, and 48 hours. Subsequently, the aged MPs were exposed in plastic-free containers to model solutions to simulate co-contaminants in the environment. Adsorption onto synthesized secondary microplastics, varying in size and aging status, was investigated at different time intervals with ambient MS and time-of-flight secondary ion mass spectrometry. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Mass Spectrometry KW - FAPA-MS KW - Microplastics KW - TOF-SIMS KW - Surface Analysis PY - 2025 AN - OPUS4-63606 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmitt, Johannes T1 - Data acquisition system for single particle inductively coupled plasma mass spectrometry (spICP-MS) with nanosecond time resolution N2 - This study presents our data acquisition system prototype for single particle inductively coupled plasma mass spectrometry (spICP-MS) with nanosecond time resolution (nanoDAQ) and a matching data processing approach for time-resolved data in the nanosecond range. The system continuously samples the secondary electron multiplier (SEM) detector signal with a dwell time of approximately 2 ns and enables detection of gold nanoparticles (AuNP) as small as 7.5 nm with a commercial single quadrupole ICP-MS instrument. [1] Analysis of acquired transient data is based on the temporal distance between detector events and a derived ion event density. It was shown that the inverse logarithm of the distance between detector events is proportional to particle size. Also, the number of detector events per particle can be used to calibrate and determine the particle number concentration (PNC) of a nanoparticle dispersion. [1] Particle-by-particle-based analysis of ion event density and other parameters derived from nanosecond time resolution show promising results. High data acquisition frequency of the systems allows recording of a statistically significant number of data points in 60 s or less, which leaves only the sample uptake and rinsing steps as remaining factors for limiting the total measurement time. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - ICP-MS KW - Instrumentation KW - Nano KW - Nanoparticle Characterization PY - 2025 AN - OPUS4-63603 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chan, George C.-Y. A1 - Hieftje, Gary M. A1 - Omenetto, Nicoló A1 - Axner, Ove A1 - Bengtson, Arne A1 - Bings, Nicolas H. A1 - Blades, Michael W. A1 - Bogaerts, Annemie A1 - Bolshov, Mikhail A. A1 - Broekaert, José A.C. A1 - Chan, WingTat A1 - Costa-Fernández, José M. A1 - Crouch, Stanley R. A1 - De Giacomo, Alessandro A1 - D’Ulivo, Alessandro A1 - Engelhard, Carsten A1 - Falk, Heinz A1 - Farnsworth, Paul B. A1 - Florek, Stefan A1 - Gamez, Gerardo A1 - Gornushkin, Igor B. A1 - Günther, Detlef A1 - Hahn, David W. A1 - Hang, Wei A1 - Hoffmann, Volker A1 - Jakubowski, Norbert A1 - Karanassios, Vassili A1 - Koppenaal, David W. A1 - Kenneth Marcus, R. A1 - Noll, Reinhard A1 - Olesik, John W. A1 - Palleschi, Vincenzo A1 - Panne, Ulrich A1 - Pisonero, Jorge A1 - Ray, Steven J. A1 - Resano, Martín A1 - Russo, Richard E. A1 - Scheeline, Alexander A1 - Smith, Benjamin W. A1 - Sturgeon, Ralph E. A1 - Todolí, José-Luis A1 - Tognoni, Elisabetta A1 - Vanhaecke, Frank A1 - Webb, Michael R. A1 - Winefordner, James D. A1 - Yang, Lu A1 - Yu, Jin A1 - Zhang, Zhanxia T1 - Landmark Publications in Analytical Atomic Spectrometry: Fundamentals and Instrumentation Development N2 - The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings and instrumental innovations of the original work must be sacrificed. In the present compilation, this dilemma is overcome by assembling the most impactful publications in the area of analytical atomic spectrometry. Each entry was proposed by at least one current expert in the field and supported by a narrative that justifies its inclusion. The entries were then assembled into a coherent sequence and returned to contributors for a round-robin review. KW - Analytical atomic spectrometry KW - Spectroscopy KW - Instrumental analysis PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-621588 DO - https://doi.org/10.1177/00037028241263567 SN - 1943-3530 VL - 78 SP - 1 EP - 456 PB - Sage CY - London AN - OPUS4-62158 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kipphardt, Heinrich A1 - Tuma, Dirk A1 - Khanipour, Peyman A1 - Maiwald, Michael T1 - Voll normal - Normen in der Gasanalytik N2 - In dieser Arbeit werden die Grundlagen der Normung, die Entstehung einer Norm und die für die Gasanalytik relevanten Normungsgremien kurz dargestellt. Dazu werden die wichtigsten Normen zur Gasanalytik entlang des analytischen Prozesses gruppiert und aufgeführt. Schließlich wird als Anwendungsbeispiel aus der eigenen Praxis der Prozess von der Herstellung bis zur Zertifizierung eines Kalibriergases beschrieben. KW - Zertifikat KW - Regel- und Messtechnik KW - Normung KW - Gasanalytik KW - Gasgualität KW - Gasreinheit PY - 2022 SN - 2366-9594 VL - 10 SP - 73 EP - 80 PB - Vulkan Verlag CY - Essen AN - OPUS4-56083 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heinelt, Manuel T1 - Feasibility Study on the Direct Detection of Per- and Polyfluoroalkyl Substances (PFAS) with Surface-Assisted Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (SA-FAPA-MS) N2 - Per- and polyfluoroalkyl substances (PFAS) are a large class of thousands of synthetic chemicals that are used worldwide. However, growing environmental and human health concerns in the last two decades have led to more stringent regulatory requirements and the development of quantitative analytical methods for PFAS detection. Today, standardized and powerful methods exist, e.g., for the determination of PFAS in water, sludge, compost, soil, and drinking water (DIN 38407-42, DIN 38414-14, ISO 21675, and DIN EN 17892). While liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is often used, blank levels, sample preparation, and total analysis times can be challenging. [1] Here, ambient desorption/ionization mass spectrometry (ADI-MS) is considered interesting because it requires only minimal sample preparation and was able to reduce total analysis time in other types of applications. [2] Previously, we used a plasma-based pin-to-capillary flowing atmospheric-pressure afterglow source (FAPA) [3] to probe samples directly from thin-layer chromatography (TLC) plates and to perform quantitative analysis and mass spectral imaging [4]. In this work, a feasibility study for the direct detection of PFAS with FAPA-MS is reported. Selected PFAS samples were directly probed on functionalized TLC surfaces (normal-phase silica, reversed-phase-modified silica, cyano [CN]-modified silica, and dimethyl [RP2]-modified silica, diol modified silica, and amino [NH2]-modified silica). The suitability of the surfaces was evaluated and the compatibility of different solvents with the surfaces was studied. CN-HPTLC and RP2-TLC surfaces showed the best performance for direct PFAS detection with FAPA-MS. In addition, direct analysis of PFAS mixtures and selected matrices was performed with little sample preparation and short analysis time. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Mass Spectrometry KW - FAPA-MS KW - Instrumentation KW - PFAS KW - Surface Analysis PY - 2025 AN - OPUS4-63605 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heinelt, Manuel T1 - Feasibility Study on the Direct Detection of Per- and Polyfluoroalkyl Substances (PFAS) with Surface-Assisted Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (SA-FAPA-MS) N2 - Per- and polyfluoroalkyl substances (PFAS) are a large class of thousands of synthetic chemicals that are used worldwide. However, growing environmental and human health concerns in the last two decades have led to more stringent regulatory requirements and the development of quantitative analytical methods for PFAS detection. Today, standardized and powerful methods exist, e.g., for the determination of PFAS in water, sludge, compost, soil, and drinking water (DIN 38407-42, DIN 38414-14, ISO 21675, and DIN EN 17892). While liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is often used, blank levels, sample preparation, and total analysis times can be challenging. [1] Here, ambient desorption/ionization mass spectrometry (ADI-MS) is considered interesting because it requires only minimal sample preparation and was able to reduce total analysis time in other types of applications. [2] Previously, we used a plasma-based pin-to-capillary flowing atmospheric-pressure afterglow source (FAPA) [3] to probe samples directly from thin-layer chromatography (TLC) plates and to perform quantitative analysis and mass spectral imaging [4]. In this work, a feasibility study for the direct detection of PFAS with FAPA-MS is reported. Selected PFAS samples were directly probed on functionalized TLC surfaces (normal-phase silica, reversed-phase-modified silica, cyano [CN]-modified silica, and dimethyl [RP2]-modified silica, diol modified silica, and amino [NH2]-modified silica). The suitability of the surfaces was evaluated and the compatibility of different solvents with the surfaces was studied. CN-HPTLC and RP2-TLC surfaces showed the best performance for direct PFAS detection with FAPA-MS. In addition, direct analysis of PFAS mixtures and selected matrices was performed with little sample preparation and short analysis time. T2 - 56th Annual Conference of the DGMS CY - Göttingen, Germany DA - 04.03.2025 KW - FAPA-MS KW - Instrumentation KW - Mass Spectrometry KW - PFAS KW - Surface Analysis PY - 2025 AN - OPUS4-63643 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schütz, Désirée A.-M. T1 - Feasibility Study on the Adsorption of Environmental Contaminants onto Fresh and Aged Microplastics N2 - Microplastics (MPs) refer to plastic particles, fibers, or beads with sizes ranging from 100 nm to 5 mm in size. Their pervasive distribution as environmental contaminants have escalated into a significant global concern. Primary MPs are intentionally produced particles for industrial and commercial applications, such as exfoliants in personal care and cosmetic formulations. In contrast, secondary MPs are generated through the fragmentation and degradation of larger plastic materials, due to environmental weathering processes. [1] Due to their high surface area-to-volume ratio and hydrophobic nature, MPs have the potential to serve as vectors for the accumulation and transport of diverse organic contaminants, including polycyclic aromatic hydrocarbons (PAHs), perfluoroalkyl substances (PFAS), pharmaceuticals and personal care products (PPCPs), as well as trace metals such as silver, cadmium, chromium, and copper. In the environmental, MPs are subject to aging processes driven by factors such as temperature, ultraviolet radiation, oxygen, and chemical interactions with environmental toxins. This aging can induce significant alterations in their physicochemical properties, which, in turn, can affect the adsorption behavior. [2] Classical and alternative analytical methods such as high-performance liquid chromatography (HPLC) and ambient desorption/ionization high-resolution mass spectrometry (ADI-HR-MS) can help to study the adsorption potential. ADI-HR-MS allows rapid sample analysis with minimal preparation, providing results in under a minute, much faster than traditional chromatographic techniques. [3] This study aims to investigate the influence of aging and particle size on the ability of microplastics to act as vectors for environmental contaminants. Microplastics were prepared in-house and subjected to controlled aging conditions for 12, 24, 36, and 48 hours. Subsequently, the aged MPs were exposed in plastic-free containers to model solutions to simulate co-contaminants in the environment. Adsorption onto synthesized secondary microplastics, varying in size and aging status, was investigated at different time intervals with ambient MS and time-of-flight secondary ion mass spectrometry. T2 - 56th Annual Conference of the DGMS CY - Göttingen, Germany DA - 04.03.2025 KW - FAPA-MS KW - Mass Spectrometry KW - Microplastics KW - Surface Analysis KW - TOF-SIMS PY - 2025 AN - OPUS4-63644 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schardt, Annika T1 - Fast screening method for nanoparticles in surface waters via nanosecond spICP-MS and a tailored automated ion cloud recognition algorithm N2 - Single particle inductively coupled plasma mass spectrometry (spICP-MS) is a powerful technique for nanoparticle (NP) analysis in aqueous samples, which provides essential information on size distribution and particle number concentration (PNC) of nanometer-sized particles in various water samples for risk assessment and toxicity tests. In contrast to spectroscopic particle analysis methods, this mass spectrometry-based tool can provide chemical information on the elemental composition of NPs after minimal sample preparation. We recently presented a novel spICP-MS instrumentation and tailored software that acquires data with nanosecond time resolution, lowering the particle size detection limit to 7 nm for gold NP (1). The system directly samples the output signal of the electron multiplier and records the detection of individual ions with a time resolution of only a few nanoseconds. With nanosecond time resolution, we were able to visualize profiles of ion clouds that were produced from ionization of nanoparticles in the ICP on a single-ion basis and to use the temporal gap between those ions for particle sizing. Our latest improvement of the data acquisition system (nanoDAQ) features ca. 2 ns integration time and a matching processing software prototype, which automatically recognizes and counts ion clouds in the transient data. With this combination we achieved an experimentally determined size detection limit of ca. 5 nm for gold nanoparticles. A feasibility study shows that the nanoDAQ in combination with the ion cloud recognition algorithm succeeds in fast detection and counting of NP containing Ag, Ce, or Zr in waste water and surface water samples from the area of Siegen. PNCs ranged from ca. 7 x 106–2 x 108 particles/L, which is in good agreement with concentrations reported for similar water samples in the literature. T2 - 56th Annual Conference of the German Society for Mass Spectrometry (DGMS) CY - Göttingen, Germany DA - 04.03.2025 KW - Instrumentation KW - Mass Spectrometry KW - Nanoparticles KW - spICP-MS PY - 2025 AN - OPUS4-63662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Escobar-Carranza, Cristian C. T1 - On the Detection of Microplastics by Flowing Atmospheric-Pressure Afterglow Mass Spectrometry (FAPA-MS) N2 - Microplastics (MPs) are widespread pollutant particles analyzed using Raman and FTIR spectroscopy combined with optical microscopy. Pyrolysis (Py) or thermal extraction and desorption (TED) coupled with gas chromatography-mass spectrometry (GC-MS) are used for the characterization of MPs, though GC limits sample throughput. This work explores direct, rapid MP analysis using high-resolution (HR) MS and a plasma-based ambient desorption/ionization source (FAPA, flowing atmospheric-pressure afterglow). Previously, an in-house pin-to-capillary (p2c) FAPA source coupled to HRMS characterized MPs made in-house from polystyrene (PS), polypropylene (PP), low-density polyethylene (LDPE), and polycarbonate (PC). Simultaneous detection of characteristic ions and particle imaging on a sampling mesh was feasible, with detection limits (LOD) for PS MPs at 311 µm in size and 1.3 mg in mass. Principal component analysis (PCA) was used for particle differentiation. This work introduces a high-temperature desorption method (~500 °C) with economical and commercially available parts and a tailored housing combined with a halo-shaped (h-FAPA) source configuration. The study expands to include poly(ethylene terephthalate) (PET), poly(methyl methacrylate) (PMMA), and poly(vinyl chloride) (PVC) MPs (125–250 µm). Data visualization and interpretation were performed using Kendrick mass defect plots and other multivariate analysis tools. Compared to earlier results, h-FAPA-MS yielded at least 65% higher ion signals for selected ions in all MPs. These ions were detected mainly as protonated species [M+H]+. Higher thermal desorption temperatures aided in detecting all MPs, as the presence of higher molecular weight fragments added specificity to the analysis. Notably, experiments with the h-FAPA source demonstrated lower mass-based LODs for MPs than the p2c-FAPA source (e.g., 14 µg vs 1.3 mg for PS, respectively). T2 - 56th Annual Conference of the German Society for Mass Spectrometry (DGMS) CY - Göttingen, Germany DA - 04.03.2025 KW - Instrumentation KW - Mass Spectrometry KW - FAPA-MS KW - Microplastics PY - 2025 AN - OPUS4-63663 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oskoei, P. A1 - Nogueira, J. A1 - Keller, Lisa-Marie A1 - Andresen, Elina A1 - Maturi, F. E. A1 - Rühle, Bastian A1 - Resch-Genger, Ute A1 - Daniel-da-Silva, A. L. A1 - Carlos, L. D. A1 - Oliviera, H. T1 - Effects of doxorubicin-loaded UCNP@MSN core-shell particles with a thermoresponsive nanovalve in melanoma cells N2 - Melanoma, one of the most aggressive forms of skin cancer, has an increasingly higher incidence. When detected in advanced stages, tumour eradication is often incomplete, contributing to poor prognosis with conventional treatments. Upconversion nanoparticles (UCNPs) haveunique optical properties that allow their effective use in several biomedical applications. This includes the excitability under near-infrared (NIR) excitation light, which has a relatively high penetration depth in tissue, a multitude of characteristic emission bands in the ultraviolet (UV), visible (Vis), NIR, and short-wave infrared (SWIR), along with long luminescence lifetimes, and high photostability. Mesoporous silica nanoparticles (MSN) with nanovalves or derived coatings have widely been used for triggered and targeted drug delivery in the past. Anticancer drugs can be loaded into the pores of MSN, enabling spatiotemporally controlled drug release. KW - Nano KW - Particle KW - Silica KW - Upconversation KW - Lanthanide KW - Triggered release KW - Temperature KW - Cell studies KW - Drug KW - Toxicity studies PY - 2024 DO - https://doi.org/10.1016/j.toxlet.2024.07.237 SN - 0378-4274 VL - 399 IS - Supplement 2 SP - S89 EP - S90 PB - Elsevier B.V. AN - OPUS4-62571 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Oskoei, Parastu T1 - Thermoresponsive UCNP@MSN Nanoparticles for Doxorubicin Delivery in Melanoma Cells N2 - Upconversion nanoparticles (UCNPs) possess unique photophysical characteristics, such as excita bility by near infrared (NIR) light, which facilitates deep tissue penetration, multi color emission , long luminescence lifetimes, and an excellent photostability. These features have made UCNPs promising tools for biomedical applications . M esoporous silica nanoparticles (MSNs) functionalized with stimuli responsive nanovalves or specific coatings enable the encapsulation and controlled release of therapeutic agen ts, thereby offering spatiotemporal precision in drug delivery 1 3 ]]. Among drug delivery strategies, photoresponsive systems have attracted growing attention due to their potential for clinical applications . This is especially relevant for melanoma, an aggressive skin cancer with increasing global incidence, for which conventional therapeutic modalities remain largely insufficient in advanced stage 4 In this work, core shell UCNP@MSN nanoparticles were synthetised by coating UCNPs with a mesoporous silica layer, which was subsequently functionalized with thermoresponsive retro Diels Alder nanovalves [ and loaded with the chemotherapeutic agent doxorubicin (DOX). Controlled drug release was effectively achieved under 980 nm NIR i llumination . Treatment with functionalized nanoparticles significantly reduced the viability of melanoma cell lines, with an enhanced cytotoxicity being observed upon combined nanoparticle exposure and NIR illumination . Mechanistic analyses revealed that neither UCNPs nor NIR i llumination alone could induce the production of reactive oxygen species (ROS); however, their combination induced a marked increase in ROS levels in two of the three tested cell lines. Furthermore, this dual treatment promoted substantial apoptotic and/or necrotic responses across all cell models. These findings underscore the potential of UCNP@MSN nanoplatforms, equipped with thermoresponsive ga tes , as efficient photoactivated drug delivery systems for melanoma therapy. T2 - Conference Jornadas CICECO CY - Aveiro, Portugal DA - 09.10.2025 KW - Nano KW - Particle KW - Lanthanide KW - Upconversion KW - Surface chemistry KW - Mesoporous silica KW - Doxorubicin KW - Nanomedicine KW - Triggered release KW - pH KW - Cellular uptake KW - Toxicity KW - Folate KW - Ligand PY - 2025 AN - OPUS4-64371 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Oskoei, Párástu T1 - Cell mechanisms induced by doxorubicin-loaded UCNP@MSN nanoparticles with a thermosresponsive nanovalve in melanoma cells N2 - Upconversion nanoparticles (UCNPs) exhibit several remarkable optical properties, including excitation by near infrared (NIR) light, which enables deep tissue penetration, multiple distinct emission bands across a wide range of wavelengths, long luminescen ce lifetimes, and high photostability. These features make them particularly attractive for various biomedical applications. Mesoporous silica nanoparticles (MSNs), functionalized with nanovalves or specific coatings, have been explored for controlled and targeted drug delivery, where therapeutic agents are encapsulated within the nanopores, allowing spatiotemporal release 1 3 ]]. Among the promising approaches, photoactivated drug delivery systems have drawn considerable interest due to their versatility and potential. One relevant application is in the treatment of melanoma, an aggressive form of skin cancer with a rising global incidence. In advanced stages, conventional therapies often fail to achieve complete tumour eradication, resulting in poor prognose s 4 In this study, UCNPs were coated with a mesoporous silica shell to form core shell UCNP@MSN nanoparticles, which were further functionalized with thermoresponsive retro Diels Alder nanovalves and loaded with doxorubicin (DOX), a chemotherapeutic drug used in melanoma treatment. Upon exposure to 980 nm NIR light, DOX release was successfully triggered in the culture medium. Exposure to functionalized UCNPs decreased the viability of the tested melanoma cell lines, with further reductions observed when the ex posure to the nanoparticles was combined with irradiation. Subsequently, t he toxicity mechanisms were evaluated and showed that w hile individual treatments with either the functionalized UCNPs or NIR irradiation alone had no effect on reactive oxygen species (ROS) production, their combination significantly increased ROS levels in two of the three tested cell lines. This combined treatment also led to notable increases in apoptotic , necrotic or both type of cells’ percentages on all cell lines. Overall, these findings highlight the potential of these nanoparticles with thermoresponsive gating mechanisms as effective platforms for targeted drug delivery in melanoma therapy. T2 - EUROTOX 2025 CY - Athens, Greece DA - 14.09.2025 KW - Nano KW - Particle KW - Lanthanide KW - Upconversion KW - Surface chemistry KW - Mesoporous silica KW - Doxorubicin KW - Nanomedicine KW - Triggered release KW - pH KW - Cellular uptake KW - Toxicity KW - Folate KW - Ligand PY - 2025 AN - OPUS4-64372 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Oskoei, Párástu T1 - Effects of upconversion nanoparticles with a thermo-responsive nanovalve loaded with doxorubicin in melanoma cells N2 - Melanoma skin cancer has an increasingly higher incidence , and w hen detected in advanced stages, tumour eradication is often incomplete, contributing to poor prognosis with conventional treatments. Upconversion nanoparticles (UCNPs) have unique properties, such as excitability under near infrared (NIR) excitation light, which confers a relatively high penetration depth in tissue that allow their effective use in several biomedical applications Mesoporous silica nanoparticles (MSN) with nanovalves or derived coatings have widely been used for triggered and targeted drug delivery in the past. Anticancer drugs can be loaded into the pores of MSN, enabling controlled drug release. In this work, UCNPs were coated with a mesoporous silica shell yielding UCNP@MSN core shell nanoparticles which were equipped with thermoresponsive retro Diels Alder nanovalves and then loaded with DOX , a chemotherapeutic agent for melanoma treatmen t (UCNP@MSN DOX) Subsequent DOX release from this drug delivery system was triggered by 980 nm NIR light. Melanoma cells exposed to UCNP@MSN DOX or the NIR laser exhibited no change in ROS production , while the combination of both induced an increase in ROS production. This combination of conditions also induced changes on apoptosis and necrosis levels. These findings underscore the potential use of UCNP @MSN drug delivery systems with thermoresponsive caps as effective drug delivery platforms for melanoma therapy. T2 - VII iBiMED Symposium CY - Aveiro, Portugal DA - 23.05.2025 KW - Nano KW - Particle KW - Lanthanide KW - Upconversion KW - Surface chemistry KW - Mesoporous silica KW - Doxorubicin KW - Nanomedicine KW - Triggered release KW - pH KW - Cellular uptake KW - Toxicity KW - Folate KW - Ligand PY - 2025 AN - OPUS4-64373 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Heide, Maximilian A1 - Reifenrath, Jonas A1 - Herrmann, Alexander A1 - Engelhard, Carsten T1 - Fast and Sustainable Active Pharmaceutical Ingredient (API) Screening in Over-the-Counter and Prescription Drug Products by Surface-Assisted Plasma-Based Desorption/Ionization High-Resolution Mass Spectrometry N2 - Fast chemical analysis of pharmaceutical preparations is important for quality assurance, counterfeit drug detection, and consumer health. While quantitative methods such as high-performance liquid chromatography mass spectrometry (HPLC-MS) are powerful, there is a need for sustainable and environmentally friendly methods, which require less chemicals and produce less waste. Here, solvent-free ambient desorption/ionization (ADI) MS methods are attractive because they do not require time-consuming chromatography, produce little to no chemical waste, and, thus, contribute to green chemistry practice. In addition, sample throughput can be higher compared to HPLC-MS. In this study, a method for direct analysis of single- and multi agent drugs using a plasma-based ADI source (flowing atmospheric-pressure afterglow, FAPA) coupled to high-resolution (HR) MS was developed and optimized for best performance. The approach is rapid and only requires analytes to be in solution (only a few µL) before application onto thin-layer chromatography (TLC) surfaces, specifically dimethyl (RP2-) and cyano (CN-) modified silica, for surface-assisted (SA) FAPA-HRMS measurements. No chromatographic separation was required, and the TLC plates served only as sample carriers. A broad variety of 19 active pharmaceutical ingredients (APIs) was carefully selected to cover analgesics, anesthetics, antibiotics, antiepileptics, calcium channel blockers, diuretics, expectorants, opioids, peripheral vasodilators, stimulants, and sympathomimetics. Fast screening and identification of APIs was performed by SA-FAPA-HRMS. Typically, the protonated molecular ion ([M+H]+) was the most abundant species, while some compounds (codeine, metamizole, phenoxymethylpenicillin, and torasemide) did show some degree of fragmentation. As a proof-of-principle application, benzocaine was directly detected in saliva samples post-intake of a lozenge. Time-resolved semi-quantitative screening was performed. The limit of detection for benzocaine in saliva was 8 ng/mL (48.4 fmol) using internal standard calibration and CN-HPTLC plates. In addition, direct quantification of artificially spiked saliva was performed with minimal sample preparation. Here, SA-FAPA-HRMS with a CN-HPTLC sample substrate yielded best performance (20.02±0.52 µg/mL, RSD=2.6%, deviation of -1.9% from the theoretical value) compared to RP2-TLC (18.97±1.37 µg/mL, RSD=7.2%, -7.0%), and HPLC-UV (18.51±0.03 µg/mL, RSD=0.2%, -9.3%) results. In conclusion, SA FAPA HRMS is considered attractive for rapid and sustainable analysis of pharmaceuticals with potential in non-invasive patient monitoring. KW - Mass Spectrometry KW - Pharmaceuticals KW - Green Chemistry KW - Ambient Desorption/Ionization PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640718 DO - https://doi.org/10.1039/D5AY01050K SN - 1759-9660 VL - 17 IS - 18 SP - 7799 EP - 7809 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64071 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ruehle, Bastian T1 - The potential of Material Acceleration Platforms (MAPs) for creating resilient and sustainable technology value chains N2 - Material Acceleration Platforms (MAPs) represent a transformative approach to the development of resilient and sustainable technology value chains. These platforms can identify candidate chemistries and structures via simulations, and database searches and leverage machine learning-based rapid screening to accelerate the discovery and deployment of novel materials, thereby addressing critical challenges in modern technology sectors. Incorporating high-fidelity advanced characterization in the early phases of material development is crucial for early de-risking. Advanced characterization techniques, such as X-ray diffraction, advanced electrochemical and spectroscopic techniques provide comprehensive insights into the structural, chemical, and physical properties of materials. Long-term testing further contributes to the de-risking process by evaluating the durability and stability of materials under various environmental and operational conditions. Early identification of potential degradation mechanisms enables the refinement of material compositions and processing methods, ultimately leading to the development of more resilient materials. Early upscaling attempts are integral to assessing the feasibility of material leads generated through machine learning-based rapid screening to evaluate the scalability of synthesis and processing techniques. This step is critical for identifying potential challenges in manufacturing, such as issues related to reproducibility, yield, and cost-effectiveness. Process design has to be a major part of the MAP-based material design to cope with the increasing share of secondary raw materials in supply chains. This presentation will briefly summarize possible strategies to address these issues and provide deep-dives on best practices. As the demand for advanced materials continues to grow, MAPs will play an increasingly vital role in driving technological advancements and addressing global challenges. T2 - Materials Week Cyprus 2024 CY - Limassol, Cyprus DA - 17.06.2024 KW - MAPs KW - SDLs KW - Sustainability PY - 2024 AN - OPUS4-60379 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ruehle, Bastian T1 - A Self-Driving Lab for Nano and Advanced Materials Synthesis N2 - Nano- and advanced materials have been recognized as a key enabling technology of the 21st century, due to their high potential of driving innovations in new clean energy technologies, sustainable manufacturing by substitution of critical raw materials and replacement of hazardous substances, breakthroughs in energy conversion and storage, improvement of the environmental performance of products and processes, and facilitation of circularity. Consequently, new tools that enhance the development and optimization cycle of nano- and advanced materials are crucial. In this contribution, we present our Self-Driving Lab (SDL) for Nano and Advanced Materials [1], that integrates robotics for batched autonomous synthesis – from molecular precursors to fully purified nanomaterials – with automated characterization and data analysis, for a complete and reliable nanomaterial synthesis workflow. By fully automating the processing steps for seven different materials from five representative, completely different classes of nano- and advanced materials (metal, metal oxide, silica, metal organic framework, and core–shell particles) that follow different reaction mechanisms, we demonstrate the great versatility and flexibility of the platform. The system also exhibits high modularity and adaptability in terms of reaction scales and incorporates in-line characterization measurement of hydrodynamic diameter, zeta potential, and optical properties (absorbance, fluorescence). We discuss the excellent reproducibility of the various materials synthesized on the platform in terms of particle size and size distribution, and the adaptability and modularity that allows access to a diverse set of nanomaterial classes. We also present several key aspects of the central backend that orchestrates the (parallelized) syntheses workflows. One key feature is the resource management or “traffic control” for scheduling and executing parallel reactions in a multi-threaded environment. Another is the interface with data analysis algorithms from in-line, at-line, and off-line measurements. Here, we will give examples of how automatic image segmentation of electron microscopy images with the help of AI [2] can be used for reducing the “data analysis bottleneck” from an off-line measurement. We will also discuss various machine learning (ML) algorithms that are currently implemented in the backend and can be used for ML-guided, closed-loop material optimization in our SDL. Lastly, we will show our recent efforts [3] in making the workflow generation on SDLs more user-friendly by using large language models to generate executable workflows automatically from synthesis procedures given in natural language and user-friendly graphical user interfaces based on node editors that also allow for knowledge graph extraction from the workflows. In this context, we are currently also working on a common description or ontology for representing the process steps and parameters of the workflows, which will greatly facilitate the semantic description and interoperability of workflows between different SDL hardware and software platforms. These features underscore the SDL’s potential as a transformative tool for advancing and accelerating the development of nano- and advanced materials, offering solutions for a sustainable and environmentally responsible future. T2 - MRS Fall Meeting 2025 CY - Boston, MA, USA DA - 30.11.2025 KW - Self-Driving Labs KW - Materials Acceleration Platforms KW - Advanced Materials KW - Nanomaterials KW - Automation PY - 2025 AN - OPUS4-65129 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bayat, Mehmet E. A1 - Huber, C. A1 - Kipphardt, Heinrich A1 - Tiebe, Carlo A1 - Engelhard, Carsten T1 - Towards a sensor-based methodology to determine online calorific values of H2-enriched natural gases in the grid N2 - The German National Hydrogen Strategy (NWS) envisions a transition towards a hydrogen-based energy grid. However, due to the material incompatibility of existing pipeline infrastructure for amounts of hydrogen higher than 10 cmol/mol, many system components of the existing grid must be replaced with significant costs and considerable time investments. Given these constraints, the admixture of hydrogen into natural gas (NG) to create a hydrogen-enriched NG blend has been designated as a transitional technology. The NWS supports this approach on a regional and time-limited basis, but clearly states that it is not intended as a permanent solution. Nevertheless, the conversion to a fully hydrogen-based grid is expected to take several decades. During this transitional phase, precise process analytical monitoring of hydrogen amounts in the NG blend is essential to ensure both energy efficiency via calorific value control and operational safety. These procedures require cost-effective, robust, and reliable sensor technologies capable of real-time, in situ/on-site quantification of hydrogen amounts in NG. In response to this need, we have advanced a physical sensing approach utilizing an oscillating cantilever in collaboration with Truedyne Sensor AG. This sensor system enables quantification of hydrogen amounts, direct calorific value determination as well as display of beneficial gas properties, like density, viscosity, and thermal conductivity. Moreover, the enhanced cantilever system enables direct physical sensing and can also be operated in a quasi-binary mode. We performed comparative evaluations against two benchmark sensor systems to validate the developed technology. One utilizes chemical sensing, and the other operates on thermal conductivity measurements for hydrogen quantification. Through standardized testing, we demonstrated that the cantilever-based sensor offers both high effectiveness and competitive performance compared to current state-of-the-art technologies for accurate hydrogen detection in natural gas and precise determination of its calorific value. T2 - Gas Analysis 2026 CY - Paris, France DA - 27.01.2026 KW - Hydrogen KW - Natural Gas KW - Sensor KW - Calorific Value KW - Grid PY - 2026 AN - OPUS4-65505 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zaki, Mohammad A1 - Prinz, Carsten A1 - Ruehle, Bastian T1 - A Self-Driving Lab for Nano- and Advanced Materials Synthesis N2 - The recent emergence of self-driving laboratories (SDL) and material acceleration platforms (MAPs) demonstrates the ability of these systems to change the way chemistry and material syntheses will be performed in the future. Especially in conjunction with nano- and advanced materials which are generally recognized for their great potential in solving current material science challenges, such systems can make disrupting contributions. Here, we describe in detail MINERVA, an SDL specifically built and designed for the synthesis, purification, and in line characterization of nano- and advanced materials. By fully automating these three process steps for seven different materials from five representative, completely different classes of nano- and advanced materials (metal, metal oxide, silica, metal organic framework, and core–shell particles) that follow different reaction mechanisms, we demonstrate the great versatility and flexibility of the platform. We further study the reproducibility and particle size distributions of these seven representative materials in depth and show the excellent performance of the platform when synthesizing these material classes. Lastly, we discuss the design considerations as well as the hardware and software components that went into building the platform and make all of the components publicly available. KW - Self-driving laboratories KW - Materials acceleration platforms KW - Nanomaterials KW - Advanced materials KW - Automation KW - Robotics KW - In-line characterization PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-627361 DO - https://doi.org/10.1021/acsnano.4c17504 SN - 1936-086X VL - 19 IS - 9 SP - 9029 EP - 9041 PB - ACS Publications CY - Washington, DC AN - OPUS4-62736 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Competence Center nano@BAM Welcomes ISO/TC 229 Meeting in Berlin N2 - The Competence Center nano@BAM is presented. Examples directly related to the activities of the ISO Technical Committee TC 229 Nanotechnologies as well as BAM projects on nano reference measurement procedures, nano reference materials and nano reference data sets are showed. T2 - The 32nd ISO/TC 229 IEC/TC 113 JWG2 General Meeting CY - Berlin, Germany DA - 06.11.2023 KW - ISO/TC 229 Nanotechnologies KW - Nanoparticles KW - Nano@BAM KW - Reference materials KW - Reference data KW - Reference procedures PY - 2023 AN - OPUS4-58814 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mrkwitschka, Paul T1 - Correlative analysis with electron microscopy applied in different operating modes (SEM, STEM-in-SEM and TEM) for the accurate morphological characterisation of non-spherical fine nanoparticles N2 - Electron microscopy applied in different operating modes, e.g., SEM, TEM or STEM-in-SEM, is the gold standard method to investigate the exact size and shape of individual nanoparticles. However, when fine nanoparticles with a non-monodisperse size distribution and non-spherical shapes are analysed, achieving an accurate result is challenging. Deviations in size measurements of more than 10% may occur. Understanding of the contrasts and sensitivities characteristic to the individual operating modes of an electron microscope is key in interpreting and evaluating quantitatively the measurement uncertainties needed for an eventual certification of specific nanoparticles via traceable results. Further, beyond the pure measurement, the other components in the analysis workflow with significant impact on the overall measurement uncertainties are the sample preparation and the image segmentation. In the present study the same areas of selected iron oxide fine nanoparticles (<25 nm) as reference nanomaterial (candidate) prepared on substrate for electron microscopy imaging are analysed correlatively with SEM, STEM-in-SEM and TEM with respect to their size and shape distribution. Individual significant measurement uncertainties are discussed, e.g., the sensitivity of secondary electron detectors of InLens-type to the surface morphology, particularly to the presence of an ultrathin organic coating or signal saturation effects on the particle edges, to electron beam exposure, to surface contamination, or the selection of the threshold for image segmentation. Another goal of this study is to establish a basis of analysis conditions which shall guarantee accurate results when both manual and particularly (semi-)automated segmentation approaches are applied. Advantages as well as limitations of the use of different electron microscopy operating modes, applied individually and correlatively, are highlighted. T2 - E-MRS 2024 Spring Meeting CY - Strasbourg, France DA - 27.05.2024 KW - Nanoparticles KW - Electron Microscopy KW - Metrology KW - Imaging KW - Reference materials PY - 2024 AN - OPUS4-60436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mrkwitschka, Paul A1 - Hodoroaba, Vasile-Dan T1 - Understanding Correlative Electron Microscopy Imaging with SEM, STEM in SEM and TEM for the Accurate Characterization of Size and Shape of FeOx Nanoparticles N2 - The recently certified reference material (CRM) BAM-N012 as cubical iron oxide FeOx nanoparticles (NPs) of 8 nm area equivalent square edge length (ESL) and the RM candidate BAM-N013 as nearly spherical NPs of 22 nm size were analyzed in detail by electron microscopy (EM). For the metrological characterization with SEM, STEM in SEM and TEM, the understanding of the imaging contrasts and sensitivities, and the correct interpretation of the (art)effects which are inherent to each detection mode is necessary. The same sample areas with NPs deposited on a TEM grid were analyzed by two SEM acquisition modes, i. e. SE InLens and STEM in SEM using a dedicated transmission sample holder, and further, correlatively, analyzed with TEM. With increasing kV, SE InLens shows increasing particle size (unless overcharging at the particle boundaries is filtered), as a known effect. For STEM-in-SEM the particle size decreases significantly and individual particles are identified easier (at 2 kV only a few single particles can be detected automatically). ❑ Documentation of the sample preparation and measurement conditions (including optimization process) is important for reproducibility. ❑ Plasma cleaning, analysis in the transmission mode at SEM is recommended for FeOx NPs. ❑ Selection of the threshold algorithm can significantly alter the reported ECD. T2 - Microscopy and Microanalysis 2024 CY - Cleveland, OH, USA DA - 28.07.2024 KW - Nanoparticles KW - Electron microscopy KW - Iron oxide KW - Reference materials KW - Correlative microscopy KW - Size and shape distribution PY - 2024 AN - OPUS4-60806 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mrkwitschka, Paul T1 - Understanding Correlative Electron Microscopy Imaging with SEM, STEM-in-SEM and TEM for the Accurate Characterization of Size and Shape of FeOx Nanoparticles N2 - The recently certified reference material (CRM) BAM-N012 as cubical iron oxide FeOx nanoparticles (NPs) of 8 nm area equivalent square edge length (ESL) and the RM candidate BAM-N013 as nearly spherical NPs of 22 nm size were analyzed in detail by electron microscopy (EM). For the metrological characterization with SEM, STEM in SEM and TEM, the understanding of the imaging contrasts and sensitivities, and the correct interpretation of the (art)effects which are inherent to each detection mode is necessary. The same sample areas with NPs deposited on a TEM grid were analyzed by two SEM acquisition modes, i. e. SE InLens and STEM in SEM using a dedicated transmission sample holder, and further, correlatively, analyzed with TEM. With increasing kV, SE InLens shows increasing particle size (unless overcharging at the particle boundaries is filtered), as a known effect. For STEM-in-SEM the particle size decreases significantly and individual particles are identified easier (at 2 kV only a few single particles can be detected automatically). ❑ Documentation of the sample preparation and measurement conditions (including optimization process) is important for reproducibility. ❑ Plasma cleaning, analysis in the transmission mode at SEM is recommended for FeOx NPs. ❑ Selection of the threshold algorithm can significantly alter the reported ECD. T2 - SALSA Make and Measure 2024: Interfaces CY - Berlin, Germany DA - 11.09.2024 KW - Correlative microscopy KW - Electron microscopy KW - Iron oxide KW - Nanoparticles KW - Reference materials KW - Size and shape distribution PY - 2024 AN - OPUS4-62347 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mrkwitschka, Paul T1 - Understanding Correlative Electron Microscopy Imaging with SEM, STEM in SEM and TEM for the Accurate Characterization of Size and Shape of FeOx Nanoparticles N2 - The recently certified reference material (CRM) BAM-N012 as cubical iron oxide FeOx nanoparticles (NPs) of 8 nm area equivalent square edge length (ESL) and the RM candidate BAM-N013 as nearly spherical NPs of 22 nm size were analyzed in detail by electron microscopy (EM). For the metrological characterization with SEM, STEM in SEM and TEM, the understanding of the imaging contrasts and sensitivities, and the correct interpretation of the (art)effects which are inherent to each detection mode is necessary. The same sample areas with NPs deposited on a TEM grid were analyzed by two SEM acquisition modes, i. e. SE InLens and STEM in SEM using a dedicated transmission sample holder, and further, correlatively, analyzed with TEM. With increasing kV, SE InLens shows increasing particle size (unless overcharging at the particle boundaries is filtered), as a known effect. For STEM-in-SEM the particle size decreases significantly and individual particles are identified easier (at 2 kV only a few single particles can be detected automatically). ❑ Documentation of the sample preparation and measurement conditions (including optimization process) is important for reproducibility. ❑ Plasma cleaning, analysis in the transmission mode at SEM is recommended for FeOx NPs. ❑ Selection of the threshold algorithm can significantly alter the reported ECD T2 - 2. Treffen des DGE-Arbeitskreises SEM CY - Stuttgart, Germany DA - 26.09.2024 KW - Correlative microscopy KW - Electron microscopy KW - Iron oxide KW - Nanoparticles KW - Reference materials KW - Size and shape distribution PY - 2024 AN - OPUS4-62349 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mrkwitschka, Paul A1 - Abram, Sarah-Luise A1 - Thünemann, Andreas A1 - Rühle, Bastian A1 - Radnik, Jörg A1 - Bresch, Harald A1 - Resch-Genger, Ute A1 - Hodoroaba, Vasile-Dan T1 - The Role of Electron Microscopy in the Development of Monodisperse Cubic Iron Oxide Nanoparticles as Certified Reference Material for Size and Shape N2 - BAM is currently building up a platform of novel nanoRMs relying on iron oxide nanoparticles of different shape, size and surface chemistry. Iron oxide was chosen as a core material because of its relevance to the material and life sciences. As a first candidate of this series, we present cubic iron oxide nanoparticles with a nominal edge length of 8 nm. These particles were synthesized by thermal decomposition of iron oleate in high boiling organic solvents adapting well-known literature procedures. After dilution to a concentration suitable for electron microscopy (TEM and SEM) as well as for small-angle X-ray scattering (SAXS) measurements, the candidate nanoRM was bottled and assessed for homogeneity and stability by both methods following the guidelines of ISO 17034 and ISO Guide 35. The particle sizes obtained by both STEM-in-SEM and TEM are in excellent agreement with a minimum Feret of 8.3 nm ± 0.7 nm. The aspect ratio (AR) of the iron oxide cubes were extracted from the images as the ratio of minimum Feret to Feret resulting in an AR of 1.18 for TEM to 1.25 for SEM. Alternatively, a rectangular bounding box was fitted originating from the minimum Feret and the longest distance through the particle in perpendicular direction. This led to AR values of 1.05 for TEM and 1.12 for SEM, respectively. The results confirm the almost ideal cubic shape. KW - Reference nanoparticles KW - Iron oxide KW - Cubical shape KW - Electron microscopy KW - SAXS KW - Nano CRM KW - Size PY - 2022 DO - https://doi.org/10.1017/S1431927622003610 SN - 1435-8115 VL - 28 IS - Suppl. 1 SP - 802 EP - 805 PB - Cambridge University Press AN - OPUS4-55599 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Riedel, Soraya A1 - Hülagü, Deniz A1 - Bennet, Francesca A1 - Carl, Peter A1 - Flemig, Sabine A1 - Schmid, Thomas A1 - Schenk, J. A. A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf T1 - Electrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine in Amperometric Assays N2 - Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes. KW - Ochratoxin A KW - Amperometry KW - Cyclic voltammetry KW - Electrochemistry KW - Immunoassay PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530421 DO - https://doi.org/10.1002/celc.202100446 N1 - Geburtsname von Riedel, Soraya: Höfs, S. - Birth name of Riedel, Soraya: Höfs, S. VL - 8 IS - 13 SP - 2597 EP - 2606 AN - OPUS4-53042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mrkwitschka, Paul A1 - Rühle, Bastian A1 - Kuchenbecker, Petra A1 - Löhmann, Oliver A1 - Lindemann, Franziska A1 - Hodoroaba, Vasile-Dan T1 - Embedding and cross-sectioning as a sample preparation procedure for accurate and representative size and shape measurement of nanopowders N2 - Reliable measurement of the size of polydisperse, complex-shaped commercial nanopowders is a difficult but necessary task, e.g., for regulatory requirements and toxicity risk assessment. Suitable methods exist for the accurate characterization of the size of non-aggregated, stabilized, spherical and monodisperse nanoparticles. In contrast, industrial nanoscale powders usually require dedicated sample preparation procedures developed for the analysis method of choice. These nano-powders tend to agglomerate and/or aggregate, a behavior which in combination with an innate broad particle size distribution and irregular shape often significantly alters the achievable accuracy of the measured size parameters. The present study systematically tests two commercially available nanoscale powders using different sample preparation methods for correlative analysis by scanning electron microscopy, dynamic light scattering, Brunauer–Emmet–Teller method and differential mobility analysis. One focus was set on the sample preparation by embedding nanoparticles in carbon-based hot-mounting resin. Literature on this topic is scarce and the accuracy of the data extracted from cross sections of these particles is unclearly stated. In this paper systematic simulations on the deviation of the size parameters of well-defined series of nanoparticles with different shapes from the nominal value were carried out and the contributing factors are discussed. KW - Nanopowder KW - Electron microscopy KW - Sample preparation KW - Cross-sectioning KW - Cerium oxide KW - Zinc oxide PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-593289 DO - https://doi.org/10.1038/s41598-023-51094-0 SN - 2045-2322 VL - 14 SP - 1 EP - 10 PB - Springer Nature CY - London AN - OPUS4-59328 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mrkwitschka, Paul A1 - Abram, Sarah-Luise A1 - Rühle, Bastian A1 - Hodoroaba, Vasile-Dan T1 - Understanding Correlative Electron Microscopy Imaging with SEM, STEM-in-SEM and TEM for the Accurate Characterization of Size and Shape of Iron Oxide Nanoparticles N2 - The recently certified reference material (CRM) BAM-N012 as cubical iron oxide FeOx nanoparticles (NPs) of 8 nm area equivalent square edge length (ESL) and the RM candidate BAM-N013 as nearly spherical NPs of 22 nm size were analyzed in detail by electron microscopy (EM). For the metrological characterization with SEM, STEM in SEM and TEM, the understanding of the imaging contrasts and sensitivities, and the correct interpretation of the (art)effects which are inherent to each detection mode is necessary. The same sample areas with NPs deposited on a TEM grid were analyzed by two SEM acquisition modes, i. e. SE InLens and STEM in SEM using a dedicated transmission sample holder, and further, correlatively, analyzed with TEM. With increasing kV, SE InLens shows increasing particle size (unless overcharging at the particle boundaries is filtered), as a known effect. For STEM-in-SEM the particle size decreases significantly and individual particles are identified easier (at 2 kV only a few single particles can be detected automatically). ❑ Documentation of the sample preparation and measurement conditions (including optimization process) is important for reproducibility. ❑ Plasma cleaning, analysis in the transmission mode at SEM is recommended for FeOx NPs. ❑ Selection of the threshold algorithm can significantly alter the reported ECD. KW - Nanoparticles KW - Iron oxide KW - Electron microscopy KW - Reference materials KW - Particle size distribution KW - Imaging PY - 2024 DO - https://doi.org/10.1093/mam/ozae044.339 VL - 30 IS - Supplement_1 SP - 710 EP - 711 PB - Oxford University Press (OUP) AN - OPUS4-61007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Onyenso, Gabriel A1 - AI-Zawity, Jiwar A1 - Farahbakhsh, Nastaran A1 - Schardt, Annika A1 - Yadigarli, Aydan A1 - Vakamulla Raghu, Swathi Naidu A1 - Engelhard, Carsten A1 - Müller, Mareike A1 - Schönherr, Holger A1 - Killian, Manuela S. T1 - Novel Ag-modified zirconia nanomaterials with antibacterial activity N2 - The outcome of an implant procedure largely depends on the implant's surface properties. Biomaterials are now designed to have surfaces with multifunctionality, such as favorable tissue integration and the ability to combat bacterial adhesion and colonization. Herein, we report on a simple approach to improve the antibacterial properties of zirconia nanotubes (ZrNTs) coatings by decorating with silver nanoparticles (AgNP), achieved through electrochemical anodization of a zirconium–silver alloy (Zr–Ag). The AgNPs were shown to partially consist of Ag2O, potentially enhancing the availability of Ag+ ions for antibacterial activity. The modified ZrNTs were characterized using SEM, EDS, ToF-SIMS, and XPS to determine their structural morphology and chemical composition, and were further subjected to antibacterial testing. The silver and zirconium ion release behavior was monitored via ICP-MS. ZrNTs decorated with AgNP exhibit strong antimicrobial activity (>99% bacterial killing) against both S. aureus and E. coli. Antimicrobial tests indicate that the antibacterial activity against the Gram-positive pathogen S. aureus was improved by a factor of 100 compared to unmodified ZrNTs, while unmodified ZrNTs already showed a comparable reduction of viable Gram-negative E. coli. This strategy illustrates a straightforward and effective modification that optimizes the interface between the host environment and the biomaterial surface to meet the very important criteria of biocompatibility and active antibacterial response. KW - Mass Spectrometry KW - Nanoparticles KW - Advanced Materials KW - ICP-MS KW - Antimicrobial material KW - ToF-SIMS PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653990 DO - https://doi.org/10.1039/d5ra07099f SN - 2046-2069 VL - 16 IS - 3 SP - 2286 EP - 2297 PB - Royal Society of Chemistry (RSC) AN - OPUS4-65399 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bayat, Mehmet Emin A1 - Kipphardt, Heinrich A1 - Tiebe, Carlo A1 - Tuma, Dirk A1 - Engelhard, Carsten T1 - Trace-Level Ammonia–Water Interactions in Hydrogen: Challenges in Gas Purity Analysis Using Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) N2 - Ammonia is a critical impurity in hydrogen fuel due to its irreversible poisoning effect on proton exchange membrane fuel cells. Therefore, international standards (e.g., ISO 14687) set a stringent threshold of 100 nmol/mol. Furthermore, with the growing potential use of ammonia as a hydrogen carrier, its accurate quantification is becoming increasingly important. However, the presence of trace humidity poses analytical challenges, as ammonia may interact with water or interfaces, thereby affecting its detectability. Therefore, the goal of this work is to enable accurate trace ammonia quantification for hydrogen purity measurements through fundamental studies of the methodological challenges. Here, low-pressure sampling (ultra)long-path Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) was applied with an effective optical path length of approximately 6.17 km. We studied three average amounts of ammonia: (38.2 ± 0.8) nmol/mol, (74.8 ± 0.7) nmol/mol, and (112.1 ± 1.2) nmol/mol. Furthermore, these amounts were investigated at trace-humidity levels ranging from 0.8 to 8.5 ppmV. We observed a systematic, nonlinear, and humidity-dependent positive measurement bias of up to + (1.0 ± 0.2) nmol/mol at the maximum investigated trace-humidity volume fraction of 8.5 ppmV. This bias was not caused by spectral interference but rather by water-induced accumulation of ammonia within the optical cavity. Moreover, time-resolved measurements in the presence of trace ammonia showed that water desorption follows first-order kinetics, whereas water adsorption followed mixed-order kinetics with an apparent reaction order of 1.57 ± 0.03. Distinct hydration states of surface-bound ammonia were identified, whereas under dry conditions and with increasing amounts of ammonia, enhanced surface adhesion through intermolecular clustering was observed. In addition, the presence of ammonium species within the sorption layer was indirectly confirmed by our experiments. In conclusion, we provide a deeper insight into trace-level ammonia–water interactions and establish a framework for optimizing methodologies, particularly for (ultra)long-path optical gas measurement systems. KW - Ammonia KW - Hydrogen KW - OF-CEAS KW - Humidity KW - Surface Interactions KW - Adsorption PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643627 DO - https://doi.org/10.1021/acsmeasuresciau.5c00105 SN - 2694-250X SP - 1 EP - 15 PB - American Chemical Society (ACS) AN - OPUS4-64362 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bayat, Mehmet A1 - Kipphardt, Heinrich A1 - Tiebe, Carlo A1 - Engelhard, Carsten T1 - Effect of Trace Humidity on Trace Ammonia Quantification N2 - Hydrogen is receiving growing attention as a promising medium for energy storage and transportation. Proton exchange membrane (PEM) fuel cells are a key technology for energy conversion from hydrogen. However, high purity hydrogen is required for this technology, as described in standards such as ISO 14687:2019. A critical impurity that impairs PEM efficiency is ammonia, for which a limit value of 100 nmol/mol applies. In addition, the maximum amount of humidity is specified with 5 µmol/mol. The presence of humidity in hydrogen at levels up to 50 times higher than ammonia raises the critical question of whether ammonia can still be quantified accurately in the lower nmol/mol range without interference from water. In addition, the general question arises as to whether the critical analyte, ammonia, can still be detected at all, given the expected surface effects at such amounts of trace humidity. In this work, we describe the influence of trace humidity on the surface behavior of adsorbed ammonia on stainless steel. Samples with ammonia at approximately 100 nmol/mol in hydrogen, with trace humidity levels ranging from 3 µmol/mol to 10 µmol/mol, were carefully prepared using dynamic mixing. Humidification was conducted using an advanced saturation method. These samples were investigated under atmospheric conditions using low pressure sampling Optical Feedback Cavity Enhanced Absorption Spectroscopy (OFCEAS). From the observed time-dependent signals, kinetics were determined and analyzed, yielding insights on the strength of the adsorption behavior of the analytes. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - OF-CEAS KW - Hydrogen KW - Ammonia KW - Water KW - Humidity KW - Kinetics KW - Adsorption PY - 2025 UR - https://veranstaltungen.gdch.de/microsite/index.cfm?l=11713&sp_id=2&selSiteID=vplanner AN - OPUS4-64046 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bernardino, Carolina T1 - Effortless Antimicrobial Shield: Spray-coated Silica Nanoparticles For Safer High-touch Surfaces N2 - Functional films with tailored interfacial properties play a pivotal role for the development of next generation surface coatings, particularly in healthcare-related environments. In this contribution, we present a facile spray-coating method for the creation of antimicrobial thin films on high-touch surfaces using mesoporous silica nanoparticles (MSNs) that were specifically functionalized to enable strong adhesion and sustained release of metal-based antimicrobial agents. The process is scalable and addresses key challenges in adhesion control, film homogeneity, and long-term antimicrobial function against a large range of key pathogens responsible for nosocomial infections. Three distinct types of MSNs – bearing amine (MSN-NH₂), carboxy (MSN-COOH), and thiol (MSN-SH) surface groups – were synthesized to optimize both metal ion loading and interactions with polyelectrolyte-based adhesion layers. These surface modifications not only provide chemical handles for Cu²⁺ and Ag⁺ ion coordination but also modulate nanoparticle-substrate interactions and dispersion behavior during film formation. The coating architecture consists of a two-step process: first, spray deposition of polyelectrolyte primers that anchor strongly to stainless steel substrates; second, a nanoparticle layer that bonds electrostatically and chemically to the primer, forming robust films with great surface coverage. The films were characterized to assess structural integrity, adhesion, and functional performance. Transmission electron microscopy (TEM) and N₂ sorption analysis confirmed the mesoporous structure. ATR-FTIR and zeta potential measurements validated surface functionalization and colloidal stability. Environmental SEM revealed conformal coating across the stainless-steel surfaces with uniform nanoparticle distribution. The coating's adhesion strength was maintained through mechanical wiping and simulated wear and abrasion tests, demonstrating film durability relevant in real-world use scenarios. Antimicrobial testing under semi-dry, application-relevant conditions showed excellent performance for Ag⁺-loaded MSN-SH films, inhibiting growth of Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, and Candida albicans. These results highlight the synergistic role of surface chemistry, metal ion loading, and film-substrate adhesion in creating effective and wear-resistant functional coatings. Moreover, these films do not show any cytotoxic properties towards Human Dermal Fibroblasts (HDF). This study contributes new insights into the design of multifunctional films where adhesion, surface functionality, and scalable processing are co-optimized for enhanced performance and shows how combining tailored surface chemistry and wide-ranging antimicrobial activity brings together smart material design for practical and safe use. T2 - MRS Fall Meeting 2025 CY - Boston, MA, USA DA - 30.11.2025 KW - Mesoporous silica nanoparticles KW - Silver KW - Antimicrobial KW - Coatings KW - Thin film PY - 2025 AN - OPUS4-65150 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Fischer, Janina T1 - Suspensionsarray-Fluoreszenzimmunoassay zur Multiplexbestimmung von SARS-CoV-2-Antikörpern N2 - Übergeordnetes Ziel der Arbeit war die Entwicklung und Optimierung eines Suspensionsarray-Fluoreszenzimmunoassays (SAFIA) für die simultane Bestimmung verschiedener gegen SARS-CoV-2-Proteine gerichtete Antikörper mittels Multiplexdetektion in komplexen Matrices wie humanen Blutserumproben. KW - SARS-CoV-2 KW - Corona KW - COVID-19 KW - Coronavirus KW - Virus KW - Spike-Protein KW - Nucleocapsid-Protein KW - RBD KW - SAFIA KW - LFIA KW - ELISA KW - Partikel KW - Mutationen KW - Neutralisierende Antikörper KW - Durchflusszytometrie KW - ACE2 PY - 2022 SP - 1 EP - 99 PB - Humboldt-Universität zu Berlin CY - Berlin AN - OPUS4-54722 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kaufmann, Jan Ole A1 - Brangsch, J. A1 - Kader, A. A1 - Saatz, Jessica A1 - Mangarova, D. B. A1 - Zacharias, M. A1 - Kempf, W. E. A1 - Schwaar, T. A1 - Ponader, Marco A1 - Adams, L. C. A1 - Möckel, J. A1 - Botnar, R. M. A1 - Taupitz, M. A1 - Mägdefessel, L. A1 - Traub, Heike A1 - Hamm, B. A1 - Weller, Michael G. A1 - Makowski, M. R. T1 - ADAMTS4-specific MR-probe to assess aortic aneurysms in vivo using synthetic peptide libraries N2 - The incidence of abdominal aortic aneurysms (AAAs) has substantially increased during the last 20 years and their rupture remains the third most common cause of sudden death in the cardiovascular field after myocardial infarction and stroke. The only established clinical parameter to assess AAAs is based on the aneurysm size. Novel biomarkers are needed to improve the assessment of the risk of rupture. ADAMTS4 (A Disintegrin And Metalloproteinase with ThromboSpondin motifs 4) is a strongly upregulated proteoglycan cleaving enzyme in the unstable course of AAAs. In the screening of a one-bead-one-compound library against ADAMTS4, a low-molecular-weight cyclic peptide is discovered with favorable properties for in vivo molecular magnetic resonance imaging applications. After identification and characterization, it’s potential is evaluated in an AAA mouse model. The ADAMTS4-specific probe enables the in vivo imaging-based prediction of aneurysm expansion and rupture. KW - Peptide KW - Peptide library KW - OBOC library KW - Combinatorial chemistry KW - Peptide aptamers KW - Binding molecule KW - Affinity KW - Synthetic peptides KW - Contrast agent KW - Magnetic resonance imaging KW - One-bead-one-compound library KW - On-chip screening KW - Lab-on-a-chip KW - MALDI-TOF MS KW - SPR KW - Surface plasmon resonance KW - Alanine scan KW - Fluorescence label KW - MST KW - Docking KW - Chelate PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-560930 DO - https://doi.org/10.1038/s41467-022-30464-8 N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. VL - 13 IS - 1 SP - 1 EP - 18 PB - Springer Nature Limited CY - Heidelberg AN - OPUS4-56093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Engelhard, Carsten T1 - Advances in Analytical Chemistry and Mass Spectrometry to Support a Sustainable and Circular Economy N2 - Recent advances in analytical chemistry have significantly supported efforts to realize a sustainable circular economy and circular chemistry. By enabling rapid materials analysis and characterization of materials transformation throughout their life cycle, analytical methods are playing a key role in supporting waste reduction, resource recovery, pollution monitoring, and sustainable manufacturing. In this presentation, recent developments in analytical chemistry and analytical instrumentation to support a sustainable and circular economy will be reviewed and selected contributions from our laboratories will be discussed. For example, high-resolution mass spectrometry combined with chromatography is an indispensable tool for the identification and characterization of plastics. To support the transition from linear to circular chemistry, whichs prioritizes reuse, recycling, and resource efficiency, accurate and detailed chemical information about plastic materials is essential. Here, targeted and non-targeted screening approaches help to characterize, for example, the quality and safety of recycled plastics. In addition, green analytical chemistry has emerged as a topic of interest, emphasizing the use of solvent-free and low-energy methods to minimized environmental impact during analysis. Here, ambient desorption/ionization high-resoluton mass spectrometry (ADI-MS) is considered a very attractive tool because it dos not require chromatography or large amounts of solvent, reduces sample preparation time, and produces virtually no chemical waste. Here, a solvent-free, plasma-based ADI-MS method is presented, which was carefuly developed for the direct identification and fast screening of per- and polyfluoroalkyl substances (PFAS). PFAS are a large class of thousands of synthetic chemicals that are used worldwide. However, growing environmental and human health concerns in the last two decades have led to more stringent regulatory requirements and the development of quantitative analytical methods for PFAS detection. Today, standardized and powerful methods exist, e.g., for the determination PFAS in water, sludge, compost, soil, and drinking water. While liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) is often used, sample preparation, solvent consumption, and total analysis times can be challenging. Here, ADI-MS is considered interesting, because it requires only minimal sample preparation and little solvent consumption. In this work, a plasma-based pin-to-capillary flowing atmospheric-pressure afterglow source (FAPA) is used for the direct desorption/ionization of PFAS from thin-layer chromatography (TLC) plates. Selected PFAS samples were directly probed on functionalized TLC surfaces without a preceding planar chromatography step. In addition, direct analysis of PFAS mixtures and selected matrices was performed with little solvent consumption, no sample preparation and short analysis time. T2 - XXII European Conference on Analytical Chemistry (EUROANALYSIS) CY - Barcelona, Spain DA - 31.08.2025 KW - Mass Spectrometry KW - Extractables & Leachables KW - Non-Targeted Analysis KW - PFAS KW - FAPA-MS PY - 2025 AN - OPUS4-65275 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bayat, Mehmet Emin T1 - Traceable dynamic and gravimetric preparation of trace ammonia in hydrogen gas standards for ISO 14687 N2 - Trace ammonia impurities in hydrogen fuel poison proton-exchange-membrane fuel cells (PEMFC), causing irreversible performance degradation. Accurate quantification of ammonia in so-called Grade D hydrogen fuel is crucial for ensuring PEMFCs long-term operational stability and performance. According to ISO 14687 grade D hydrogen fuel sets a stringent threshold value of just 100 nmol/mol for ammonia impurities. Given the potential of an ammonia-based hydrogen supply chain, reliable quantification of ammonia contamination appears even more relevant. Hydrogen quality assessments for ammonia impurities typically employ techniques such as gas chromatography, cavity-enhanced absorption spectroscopy, or mass spectrometry. These techniques, however, require stable reference gases for calibration and long-term method validation. Typically, gravimetrically produced reference gases are used. However, ammonia poses unique challenges due to its chemical reactivity and stickiness. By applying (ultra )long-path Optical Feedback Cavity Enhanced Absorption Spectroscopy we observed that above a certain amount of ammonia, the gravimetric amount deviates from the analytically determined amount. This discrepancy most likely arises due to strong adsorption of ammonia onto the inner surface of the gas cylinder. Therefore, we investigated the lowest gravimetrically preparable amount of ammonia in hydrogen for which the analytically measured amount of the cylinder remains congruent with the gravimetric amount of substance. We further investigated the applicability of passivated cylinders for trace ammonia gas standards and compared their performance to aluminum alloy cylinders. To confirm reproducibility of our results, we conducted three independent gravimetric preparation campaigns, each employing optimizations, or changes in methodology, at different times. Finally, we investigated whether those gravimetrically prepared trace amounts of ammonia in hydrogen gas standards were long-term-stable. Beyond gravimetrically prepared gas standards, we evaluated how a cutting-edge dynamic dilution system could reliably extend trace-ammonia calibration down to the ISO limit of 100 nmol/mol. For this purpose, we developed an advanced dynamic dilution system capable of a one-in-a-billion dilution ratio, validated for its SI traceability, reproducibility, and operational limits by applying an internal standard. In summary, our results demonstrate that precise dynamic dilution, coupled with concentrated gravimetrically prepared ammonia gas mixture, provides a route to full SI-traceable trace-ammonia reference sample gases. T2 - Gas Analysis Symposium 2026 CY - Paris, France DA - 27.01.2026 KW - Ammonia KW - Hydrogen KW - Gravimetric preparation KW - OF-CEAS KW - ISO 14687 PY - 2026 AN - OPUS4-65620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Correlative physic-chemical analysis of advanced materials and BAM’s green and zero-related advanced materials activities – Benefits and challenges by examples N2 - Following points are presented: - Nanomaterials BAM, as research materials & CRMs, incl pre-standardization, automated analysis & automated synthesis - 2D-materials BAM HEurope ACCORDs approach Green Deal inspired correlative imaging based characterisation for safety profiling of 2D materials - Sample preparation @BAM , inclusion to standards - Thin Films @BAM as Reference Material Candidates, i) mesoporous, ii) HEA - Substitutional,Transition Me oxides as electrocatalysts a project @BAM - Sustainable mechanochemical reaction engineering projects @BAM. T2 - VAMAS Workshop Advanced Materials Challenges and Standardization Needs for a Greener World CY - Rio de Janeiro, Brazil DA - 25.09.2024 KW - Nanomaterials KW - Advanced materials KW - 2D materials KW - Sample preparation KW - Thin films KW - Reference materials KW - Safety KW - Automation PY - 2024 AN - OPUS4-61404 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -