TY - GEN A1 - Baloh, P. A1 - Bauer, L. A1 - Bendová, A. A1 - Čermák, P. A1 - Fellner, K. A1 - Ghanathe, M. A1 - Hernández Alvarez, O. E. A1 - Hricov, Š. A1 - Jochum, J. K. A1 - Kotvytska, L. A1 - Kumar, S. A1 - Labh, A. A1 - Machovec, P. A1 - Pauw, Brian Richard A1 - Ramszová, K. A1 - Walz, E. A1 - Wild, P. T1 - An Exercise in Open Data: Triple Axis Data on Si single crystal T2 - arxiv.org N2 - Efforts are rising in opening up science by making data more transparent and more easily available, including the data reduction and evaluation procedures and code. A strong foundation for this is the F.A.I.R. principle, building on Findability, Accessibility, Interoperability, and Reuse of digital assets, complemented by the letter T for trustworthyness of the data. Here, we have used data, which was made available by the Institute Laue-Langevin and can be identified using a DOI, to follow the F.A.I.R.+T. principle in extracting, evaluating and publishing triple axis data, recorded at IN3. KW - Open data KW - Neutron diffraction KW - Analysis KW - Open science PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-562257 DO - https://doi.org/10.48550/arXiv.2010.12086 SN - 2331-8422 SP - 1 EP - 4 PB - Cornell University CY - Ithaca, NY AN - OPUS4-56225 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schlegel, Moritz-Caspar A1 - Rockland, Ulrike A1 - Harrer, Andrea T1 - Informationsmaterial zu Wartung und Betrieb von Getränkekühlern N2 - „Getränkekühler optimal einsetzen“: So sparen Sie die Energiekosten und schonen das Klima. Wussten Sie, dass Sie durch den Einsatz eines effizienten Getränkekühlers (Energieeffizienzklasse B) ca. 114 € pro Jahr sparen im Vergleich zu einem weniger effizienten Gerät (Energieeffizienzklasse D)? Aber nicht immer gibt es die Möglichkeit ein Neugerät anzuschaffen. Oft werden die Kühlgeräte von Getränkeherstellern zur Präsentation ihrer Waren zur Verfügung gestellt. Trotzdem tragen am Ende die Betreiber:innen die Betriebskosten der Geräte. Aber auch beim Einsatz Ihres weniger effizienten Getränkekühler gibt es verschiedene Möglichkeiten, die Energiekosten zu senken. Beispielsweise kann schon der Einsatz einer Zeitschaltuhr zu einer Stromreduzierung von bis zu 50 Prozent oder auch die richtige Platzierung der Geräte an kühlen Orten ohne Zugluft zu einem geringeren Strombedarf von bis zu 30% führen. In unserer Checkliste für die Aufstellung und das Betreiben von Getränkekühlgeräten zeigen wir Ihnen einfache Schritte, um den Energieverbrauch schnell zu senken. KW - Getränkekühler PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-561581 SP - 1 EP - 2 CY - Berlin AN - OPUS4-56158 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ahmadi, Samim A1 - Hauffen, Jan Christian A1 - Kästner, L. A1 - Jung, P. A1 - Caire, G. A1 - Ziegler, Mathias T1 - Learned block iterative shrinkage thresholding algorithm for photothermal super resolution imaging T2 - arxiv.org N2 - Block-sparse regularization is already well-known in active thermal imaging and is used for multiple measurement based inverse problems. The main bottleneck of this method is the choice of regularization parameters which differs for each experiment. To avoid time-consuming manually selected regularization parameters, we propose a learned block-sparse optimization approach using an iterative algorithm unfolded into a deep neural network. More precisely, we show the benefits of using a learned block iterative shrinkage thresholding algorithm that is able to learn the choice of regularization parameters. In addition, this algorithm enables the determination of a suitable weight matrix to solve the underlying inverse problem. Therefore, in this paper we present the algorithm and compare it with state of the art block iterative shrinkage thresholding using synthetically generated test data and experimental test data from active thermography for defect reconstruction. Our results show that the use of the learned block-sparse optimization approach provides smaller normalized mean square errors for a small fixed number of iterations than without learning. Thus, this new approach allows to improve the convergence speed and only needs a few iterations to generate accurate defect reconstruction in photothermal super resolution imaging. KW - Iterative shrinkage thresholding algorithm KW - Neural network KW - Deep learning KW - Active thermography KW - Photothermal super resolution PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-525364 UR - https://arxiv.org/abs/2012.03547 SN - 2331-8422 SP - 1 EP - 11 PB - Cornell University CY - Ithaca, NY AN - OPUS4-52536 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ahmadi, Samim A1 - Kästner, L. A1 - Hauffen, Jan Christian A1 - Jung, P. A1 - Ziegler, Mathias T1 - Photothermal-SR-Net: A Customized Deep Unfolding Neural Network for Photothermal Super Resolution Imaging T2 - arxiv.org N2 - This paper presents deep unfolding neural networks to handle inverse problems in photothermal radiometry enabling super resolution (SR) imaging. Photothermal imaging is a well-known technique in active thermography for nondestructive inspection of defects in materials such as metals or composites. A grand challenge of active thermography is to overcome the spatial resolution limitation imposed by heat diffusion in order to accurately resolve each defect. The photothermal SR approach enables to extract high-frequency spatial components based on the deconvolution with the thermal point spread function. However, stable deconvolution can only be achieved by using the sparse structure of defect patterns, which often requires tedious, hand-crafted tuning of hyperparameters and results in computationally intensive algorithms. On this account, Photothermal-SR-Net is proposed in this paper, which performs deconvolution by deep unfolding considering the underlying physics. This enables to super resolve 2D thermal images for nondestructive testing with a substantially improved convergence rate. Since defects appear sparsely in materials, Photothermal-SR-Net applies trained blocksparsity thresholding to the acquired thermal images in each convolutional layer. The performance of the proposed approach is evaluated and discussed using various deep unfolding and thresholding approaches applied to 2D thermal images. Subsequently, studies are conducted on how to increase the reconstruction quality and the computational performance of Photothermal-SR-Net is evaluated. Thereby, it was found that the computing time for creating high-resolution images could be significantly reduced without decreasing the reconstruction quality by using pixel binning as a preprocessing step. KW - Photothermal super resolution KW - Nondestructive testing KW - Deep unfolding KW - Deep learning KW - Deep imaging KW - Physics-based deep learning KW - Laser thermography KW - Elastic net KW - Iterative shrinkage thresholding algorithm PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-525371 UR - https://arxiv.org/abs/2104.10563 SN - 2331-8422 SP - 1 EP - 10 PB - Cornell University CY - Ithaca, NY AN - OPUS4-52537 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Iwert, C. A1 - Stein, J. A1 - Appelt, C. A1 - Vogt, K. A1 - Rainer, R. J. A1 - Tummler, K. A1 - Mühle, K. A1 - Stanko, K. A1 - Schumann, J. A1 - Uebe, D. A1 - Jürchott, K. A1 - Lisec, Jan A1 - Janek, K. A1 - Gille, C. A1 - Textoris-Taube, K. A1 - Sai, S. A1 - Petersen, A. A1 - Kühl, A. A. A1 - Klipp, E. A1 - Meisel, C. A1 - Sawitzki, B. T1 - TCAIM controls effector T cell generation by preventing Mitochondria-Endoplasmic Reticulum Contact Site-initiated Cholesterol Biosynthesis T2 - bioRxiv N2 - T cells need to adapt their cellular metabolism for effector cell differentiation. This relies on alterations in mitochondrial physiology. Which signals and molecules regulate those alterations remains unclear. We recently reported, that the mitochondrial protein TCAIM inhibits activation-induced changes in mitochondrial morphology and function and thus, CD effector T cell formation. Using conditional TCAIM knock-in (KI) and knockout (KO) mice, w now show that it also applies to CD8+ T cells and more importantly, delineate the molecular processes in mitochondria by which TCAIM controls effector cell differentiation. TCAIM KI resulted in reduced activation-induced HIF1α protein expression. Metabolomics and transcriptional data in combination with mathematical flux modeling revealed an impaired induction of anabolic pathways, especially of the mevalonate pathway and cholesterol biosynthesis in TCAIM KI CD8+ T cells. Addition of cholesterol completely rescued HIF1α protein expression, activation and proliferation of TCAIM KI CD8+ T cells. At the molecular level, TCAIM delayed activation-induced mitochondria-ER contact (MERC) formation by binding to MERC promoting proteins such as RMD3 and VDAC2. In summary, we demonstrate that TCAIM suppresses effector cell differentiation by inhibiting MERC formation, which induce HIF1α-mediated increase in cellular metabolism and cholesterol biosynthesis. KW - Mass Spectroscopy KW - Metabolomics KW - Cancer PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-533543 UR - https://www.biorxiv.org/content/10.1101/2021.04.20.440500v1 DO - https://doi.org/10.1101/2021.04.20.440500 VL - April SP - 1 EP - 45 PB - Cold Spring Harbor Laboratory AN - OPUS4-53354 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schröpfer, Dirk A1 - Becker, Amadeus A1 - Kannengießer, Thomas T1 - Kurzdarstellung der Projektergebnisse: Beanspruchungsgerechte Reparatur von Schweißverbindungen bei der Fertigung von Bauteilen aus hochfesten Feinkornbaustählen N2 - Bei der Montage von Stahlkonstruktionen kommt es trotz anforderungsgerechter schweißtechnischer Fertigung vereinzelt zur Detektion von unzulässigen Unregelmäßigkeiten im Schweißbereich. In einem Forschungsprojekt (FOSTA P1311) wurden Untersuchungen durchgeführt und Kenntnisse erarbeitet, um mittelfristig vor allem KMU beanspruchungsgerechte Reparaturkonzepte zur Verfügung zu stellen. Damit können letztlich Schäden und zumeist teure Nacharbeiten verhindert und eine verbesserte Ausnutzung des hohen Festigkeitspotentials hochfester Stähle erreicht werden. Gerade KMU können mit Blick auf die Kosten für Fertigung, Schweißarbeit und Material von den Erkenntnissen beim Einsatz hochfester Stähle, die für eine effiziente Realisierung der Energiewende in Deutschland notwendig sind, profitieren. KW - MAG-Schweißen KW - Hochfester Stahl KW - Eigenspannungen KW - Thermisches Ausfugen KW - Reparaturschweißen KW - Gefügedegradation PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-555822 SP - 1 EP - 2 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-55582 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Burkert, Andreas A1 - Fischer, Joachim A1 - Lehmann, Jens A1 - Müller, Thoralf T1 - Korrosionsbeständigkeit nichtrostender Stähle an der Atmosphäre T2 - Merkblatt der Informationsstelle Edelstahl Rostfrei N2 - Über das Korrosionsverhalten nichtrostender Stähle bei atmosphärischer Beanspruchung liegen umfangreiche Erfahrungen aus jahrzehntelangen praktischen Anwendungen weltweit vor. Systematische Auslagerungsversuche unter spezifischen Umgebungsbedingungen ergänzen diese Erfahrungen. Die daraus gewonnenen Daten erlauben die beanspruchungsgerechte Werkstoffauswahl. Unter vielen atmosphärischen Bedingungen sind die nichtrostenden Stähle bei freier Bewitterung, auch unter langzeit- oder dauerfeuchten Bedingungen vollständig korrosionsbeständig. Die Auswahl der nichtrostenden Stähle muss den jeweiligen Einsatzbedingungen angepasst werden, um in jedem Fall sicherzustellen, dass der passive Zustand aufrechterhalten bzw. eine erneute Passivierung unter den Einsatzbedingungen möglich ist. Störungen der Passivschichtausbildung führen zu verminderter Korrosionsbeständigkeit mit den für nichtrostende Stähle typischen örtlichen Korrosionserscheinungen. Das Merkblatt gibt Hinweise zur Werkstoffauswahl, zur Oberflächenausführung, zur Konstruktion sowie zu Verarbeitung, Nachbehandlung und Reinigung. KW - Verarbeitung KW - Werkstoffauswahl KW - Oberflächenausführung PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-367612 UR - http://www.edelstahl-rostfrei.de/page.asp?pageID=1583 VL - 828 SP - 1 EP - 12 PB - Informationsstelle Edelstahl Rostfrei CY - Düsseldorf ET - 3. Auflage AN - OPUS4-36761 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kühl, Christiane T1 - Untersuchung der Statistik "Unfälle mit wassergefährdenden Stoffen" des Statistischen Bundesamtes aus den Jahren 2012 und 2013 im Vergleich zu den Vorjahren N2 - Die BAM untersucht regelmäßig Statistiken über Unfälle mit wassergefährdenden Stoffen sowie Datenerhebungen zu Gefahrgutunfällen. Ziel ist es, Hinweise zu Tendenzen und Lücken abzuleiten, die möglicherweise Anlass für weitere Aktivitäten und Maßnahmen geben, z. B. im rechtlichen Bereich oder in der Praxis. Regelmäßig beobachtete Unfallstatistiken über Jahre geben einen guten Überblick über das Unfallgeschehen in Deutschland. Dieser Bericht betrachtet die Jahre 2012 und 2013 im Vergleich zu den Vorjahren. KW - Gefahrgutunfälle KW - Unfallstatistik KW - Wassergefährdende Stoffe PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-369026 SP - 1 EP - 94 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-36902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Philipp, Rosemarie T1 - Traceable measurements for monitoring critical pollutants under the European Water Framework Directive (WFD) 2000/60/EC N2 - The European Water Framework Directive (WFD) 2000/60/EC specifies a list of 33 priority water pollutants. For these substances, Environmental Quality Standards (EQS), equivalent to the maximum allowable concentrations, had been defined at very low levels. EQS values refer to the whole water body, i.e. include contaminants which are associated to suspended solids or colloids present in the natural water. For several priority pollutants primary analytical methods capable of measuring the target analytes at EQS level in natural water are still missing. The project has developed and validated such methods for three selected compounds, namely Tributyltin (TBT), Polybrominated Diphenylether (PBDE) and Polycyclic Aromatic Hydrocarbons (PAH). KW - Water polluntants KW - Monitoring KW - Water analysis KW - Tributyltin KW - Polybrominated diphenylether KW - Polycyclic aromatic hydrocarbons PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-386230 SP - 1 EP - 3 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kalbe, Ute T1 - Suffos - Bedingungen suffosiver Erosionsphänomene in Böden N2 - Das Projekt befasste sich mit der Suffosion in weitgestuften Erdstoffen. Dabei werden Poren- und Gefügestrukturen visualisiert und parametrisiert. Bei der Suffosion handelt es sich um eine Form der inneren Erosion bei weitgestuften Erdstoffen, die durch Umlagerung und Abtransport feiner Sedimentteilchen im Porenraum unter dem Einfluss von Wasserströmungen hervorgerufen wird. Die Suffosion kann zu Problemen mit der Stabilität des Korngerüstes von Erdstoffen führen. Relevante Anwendungsgebiete sind z.B. im Verkehrswegebau, Hochwasserschutz und allgemeinen Erdbau zu finden. Im Rahmen des Projektes wurden solche Erosionsprozesse numerisch simuliert, um auf statistischer Grundlage Grenzzustände zu formulieren. Ziel des Projekts war es, die Erosionsprozesse numerisch zu simulieren, um auf statistischer Grundlage Grenzzustände zu formulieren. KW - Suffosion KW - Erosion KW - Verkehrswegebau KW - Hochwasserschutz PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-386296 SP - 1 EP - 4 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38629 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -