TY - CONF A1 - Meyer, Klas T1 - Field integration of benchtop NMR instruments for online monitoring and process control of a modular industrial reaction step N2 - Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectroscopy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory. Within the project CONSENS, the continuous production of high-value products in small production scale is advanced by introducing benchtop NMR spectroscopy. CONSENS is a research and innovation project on integrated control and sensing for sustainable operation of flexible intensified processes. This poster will present the first steps of the process integration of a benchtop NMR instrument for a lithiation process and outlines further fields of activity and potential challenges. Hereby, the following issues are going to be addressed: explosion-proof housing for the spectrometer, automation of signal processing (data pretreatment, evaluation and communication to the control system), flow cells and measuring conditions. Furthermore, first online spectra of the lithiation reaction in batch mode were acquired in lab scale. The reaction was performed in a 25 mL glass reactor with thermal jackets for temperature control of the reaction mixture. The Li-HMDS was dosed stepwise by using a glass syringe. First spectra in the proton and fluorine domain were recorded online using a flowrate of 3.5 mL min–1 and a simple 5 mm polytetrafluoroethylene tube (PTFE) as a flow cell. T2 - 4th Practical Applications of NMR in Industry Conference (PANIC) CY - Houston, Texas, USA DA - 15.02.2016 KW - Reaction monitoring KW - Online NMR spectroscopy PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-354427 AN - OPUS4-35442 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon T1 - First steps towards field integration of benchtop NMR spectroscopy for online monitoring and process control N2 - Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectroscopy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory. Within the project CONSENS, the continuous production of high-value products in small production scale is advanced by introducing MR-NMR spectroscopy. CONSENS is a research and innovation project on integrated control and sensing for sustainable operation of flexible intensified processes. This poster will present the first steps of the process integration of a benchtop NMR instrument for a lithiation process and outlines further fields of activity and potential challenges. Hereby, the following issues are going to be addressed: explosion-proof housing for the spectrometer, automation of signal processing (data pretreatment, evaluation and communication to the control system), flow cells and measuring conditions. Additionally, the first results of the lithiation reaction in lab scale regarding the pure components and reaction mixtures are going to be discussed. T2 - Small Molecule NMR Conference CY - Baveno, Italy DA - 17.09.2015 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351085 AN - OPUS4-35108 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon T1 - First steps towards field integration of benchtop NMR spectroscopy for online monitoring and process control N2 - Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectroscopy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical comparison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory. Within the project CONSENS, the continuous production of high-value products in small production scale is advanced by introducing MR-NMR spectroscopy. CONSENS is a research and innovation project on integrated control and sensing for sustainable operation of flexible intensified processes. This poster will present the first steps of the process integration of a benchtop NMR instrument for a lithiation process and outlines further fields of activity and potential challenges. Hereby, the following issues are going to be addressed: explosion-proof housing for the spectrometer, automation of signal processing (data pretreatment, evaluation and communication to the control system), flow cells and measuring conditions. Additionally, the first results of the lithiation reaction in lab scale regarding the pure components and reaction mixtures are going to be discussed. T2 - Pro2NMR Autum School CY - Aachen, Germany DA - 08.12.2015 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351097 AN - OPUS4-35109 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon T1 - First steps towards field integration of benchtop NMR spectroscopy for online monitoring and process control N2 - Online monitoring and process control requires fast and noninvasive analytical methods, which are able to monitor the concentration of reactants in multicomponent mixtures with parts-per-million resolution. Online NMR spectros-copy can meet these demands when flow probes are directly coupled to reactors, since this method features a high linearity between absolute signal area and sample concentration, which makes it an absolute analytical com-parison method being independent on the matrix. Due to improved magnet design and field shimming strategies portable and robust instruments have been introduced to the market by several manufacturers during the last few years. First studies with this technology showed promising results to monitor chemical reaction in the laboratory. Wthin the project CONSENS (www.consens-spire.eu), the continuous production of high-value products in small production scale is advanced by introducing benchtop NMR spectroscopy. CONSENS is a research and innovation project on inte-grated control and sensing for sustainable operation of flexible intensified processes. This poster will present the first steps of the process integration of a benchtop NMR instrument for a lithiation process and outlines further fields of activity and potential challenges. Hereby, the following issues are going to be addressed: explosion-proof housing for the spectrometer, automation of signal processing (data pretreatment, evaluation and communication to the control system), flow cells and measuring conditions. Furthermore, first online spectra of the lithiation reaction in batch mode were acquired in lab scale. The reaction was performed in a 25 mL glass reactor with thermal jackets for temperature control of the reaction mixture. The Li-HMDS was dosed stepwise by using a glass syringe. First spectra in the proton and fluorine domain were recorded online using a flowrate of 3.5 mL min–1 and a simple 5 mm polytetrafluoroethylene tube (PTFE) as a flow cell. T2 - 11. Kolloquium Prozessanalytik CY - Wien, Autria DA - 30.11.2015 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351597 AN - OPUS4-35159 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. T1 - Antibody-based SAW sensor for the detection of explosives N2 - A robust and sensitive method for the detection of the explosive trinitrotoluene (TNT) was developed. The detection limit was determined to be around 0.5 µg/L. The fast signal response of less than 1 minute shows that this approach is suitable for security and other time-critcal applications. In addition, the very low cross-reactivity highly reduces the number of false-positives in relation to competing techniques, including sniffer dogs. Due to the multianalyte ability of the SAW system, several explosives might be detected in parallel. T2 - BAM Meeting 2016 CY - Berlin, Germany DA - 17.02.2016 KW - TNT KW - Trinitrotoluene KW - Explosives KW - Airport security KW - High-speed biosensor KW - Selectivity KW - Sensitivity KW - Self-assembled monolayer KW - Gold surface KW - Immunosensor KW - Reversibility KW - Inhibition assay KW - Polyethylene glycol KW - PEG PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-366265 UR - http://f1000research.com/posters/5-1352 DO - https://doi.org/10.7490/f1000research.1112309.1 AN - OPUS4-36626 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ahmadi, Samim T1 - Neue Verfahren der thermografischen Super Resolution mit strukturierter 1D-Lasererwärmung N2 - Die thermografische ZfP basiert auf der Wechselwirkung von thermischen Wellen mit Inhomogenitäten. Die Ausbreitung von thermischen Wellen von der Wärmequelle zur Inhomogenität und zur Detektionsoberfläche entsprechend der thermischen Diffusionsgleichung führt dazu, dass zwei eng beieinander liegende Defekte fälschlicherweise als ein Defekt im gemessenen Thermogramm erkannt werden können. Um diese räumliche Auflösungsgrenze zu durchbrechen, also eine Super Resolution zu realisieren, kann die Kombination von räumlich strukturierter Erwärmung und numerischen Verfahren des Compressed Sensings verwendet werden. Für unsere Arbeiten benutzen wir Hochleistungs-Laser im Kilowatt-Bereich um die Probe entweder hochaufgelöst entlang einer Linie (1D) abzurastern oder strukturiert zu erwärmen. Die Verbesserung des räumlichen Auflösungsvermögens zur Defekterkennung hängt dann im klassischen Sinne direkt von der Anzahl der Messungen ab. Mithilfe des Compressed Sensings und Vorkenntnissen über das System ist es jedoch möglich die Anzahl der Messungen zu reduzieren und trotzdem Super Resolution zu erzielen. Wie viele Messungen notwendig sind und wie groß der Auflösungsgewinn gegenüber der konventionellen thermografischen Prüfung mit flächiger Erwärmung ist, hängt von einer Reihe von Messparametern, der Messstrategie, Probeneigenschaften und den verwendeten Rekonstruktionsalgorithmen ab. Unsere Studien befassen sich mit dem Einfluss der experimentellen Parameter, wie z.B. der Pulslänge der Laserbeleuchtung und der Größe des Laserspots. Weiterhin haben wir uns mit der Wahl der Parameter in der Rekonstruktion auseinandergesetzt, die einen Einfluss auf das im Compressed Sensing zugrundeliegende Minimierungsproblem haben. Für jeden getesteten Parametersatz wurde eine Rekonstruktionsqualität berechnet. Schließlich wurden die Defektrekonstruktionen basierend auf den Parameternsätzen verglichen, sodass eine Parameterwahl für hohe Rekonstruktionsqualitäten mit thermografischer Super Resolution empfohlen werden kann. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Super resolution KW - Thermografie KW - Strukturiert KW - Photothermisch PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527820 AN - OPUS4-52782 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, U. T1 - Schnelle Messung und tomographische Rekonstruktion von Brennflecken < 5 μm durch Aufnahmen strukturierter Prüfkörper N2 - Im Europäischen EMPIR-Projekt „NanoXSpot“ (Measurement of the focal spot size of Xray tubes with spot sizes down to 100 nm) werden neue Messmethoden für Brennflecke von Röntgenröhren entwickelt. Teil des Projektes ist die Entwicklung eines zur Lochkameramethode äquivalenten Messverfahrens für kleine Brennflecke. ASTM E 1165-20, Annex A, beschreibt die Bestimmung von Brennfleckgrößen aus Kantenprofilen von Lochaufnahmen für Röntgenröhren mit Brennflecken > 50 μm. Es wurde bereits vorgeschlagen über die Analyse der richtungsabhängigen Kantenunschärfe einer Lochblende und anschließender CT-Rekonstruktion die Intensitätsverteilung des Brennflecks äquivalent zur Lochkameraaufnahme zu berechnen. Die Lochkameramethode, wie in EN 12543-2 und ASTM E 1165-20 beschrieben, ist im unteren Größenbereich für Mikrofokusröhren nicht geeignet, da Pinholes < 10 μm schwer zu fertigen sind und lange Belichtungszeiten erwartet werden. Mit Hilfe exakt gefertigter Lochblenden sowie strukturierter Targets mit konvergierenden Strukturen wird der Bereich mit der Single-Shot-CT-Methode auf die Messung von Mikrofokusröhren, alternativ zur Vermessung von Kanten oder Strichgruppenkörpern, erweitert. Die rekonstruierten Brennfleckformen werden mit Kanten und Lochkameraaufnahmen quantitativ verglichen, um die Messgenauigkeit zu bewerten. Außerdem werden CNR und Messzeit bestimmt, um die Wirtschaftlichkeit der Verfahren zu bewerten. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Radiographie KW - Tomographie KW - Röntgenröhren KW - Charakterisierung von Brennflecken PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-526692 UR - https://jahrestagung.dgzfp.de/Programm#P15 AN - OPUS4-52669 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lecompagnon, Julien T1 - Thermografische Super Resolution mit 2D-strukturierter Erwärmung N2 - Thermografische Super Resolution ermöglicht die Auflösung von Defekten/Inhomogenitäten unterhalb des klassischen Limits, welches durch die Diffusionseigenschaften der thermischen Wellenausbreitung bestimmt wird. Basierend auf einer Kombination aus der Anwendung spezieller Abtaststrategien und einer anschließenden numerischen Optimierungsschritt bei der Datenauswertung hat sich die thermografische Super Resolution bereits bei der Detektion von 1D-Defekten gegenüber den Standard-Thermografieverfahren als überlegen erwiesen. In unserer Arbeit erweitern wir die Möglichkeiten der Methode zur effizienten Detektion und Auflösung von Defektquerschnitten mit einer vollständig 2D-strukturierten Erwärmung. Der experimentelle Ansatz basiert auf einer wiederholten räumlich strukturierten Erwärmung durch einen Hochleistungslaser. In einem zweiten Nachbearbeitungsschritt werden mehrere kohärente Messungen mittels mathematischer Optimierung und unter Ausnutzung der (Joint-) Sparsity der Defekte innerhalb des Prüfkörpers kombiniert. Als Ergebnis kann eine 2D-sparse Defekt-/ Inhomogenitätskarte erhalten werden. Da die Kombination von räumlich strukturierter Erwärmung und anschließender numerischer Kombination mehrerer kohärenter Messungen nicht nur die Auflösung verbessert, sondern auch die Messkomplexität drastisch erhöht, werden verschiedene Scanstrategien untersucht. Abschließend werden die erhaltenen Ergebnisse mit denen konventioneller thermografischer Prüfverfahren verglichen. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Thermography KW - Super-resolution KW - NDT KW - Inspection KW - Image resolution PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-526396 UR - https://jahrestagung.dgzfp.de/Programm#P45 AN - OPUS4-52639 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gautzsch, T. T1 - Luftgekoppelte Ultraschallprüfung, eine Alternative in der zerstörungsfreien Prüfung N2 - Die luftgekoppelte Ultraschallprüfung (ACUT) ist ein vielfach bewährtes zerstörungsfreies Prüfverfahren, welches von vielen Anwendern jedoch nur am Rande oder gar nicht wahrgenommen wird. Insbesondere, die nach wie vor in der Ultraschallausbildung gelehrten Theorien zur wellenlängenabhängigen minimalen detektierbaren Fehlergröße und die vermeintliche Notwendigkeit der Verwendung von Koppelmittel schrecken viele potentielle Anwender davon ab für ihr Prüfproblem ACUT in Betracht zu ziehen. Des Weiteren wird ACUT häufig nicht als eigenständiges Prüfverfahren erkannt, sodass versucht wird, flüssigkeitsgekoppelte Ultraschallprüfungen ohne Beachtung der Besonderheiten zu ersetzen. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Luftgekoppelte Ultraschallprüfung PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-526431 UR - https://jahrestagung.dgzfp.de/Programm#P53 AN - OPUS4-52643 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Karafiludis, Stephanos T1 - Trash to treasure: recovery of transition metal phosphates for (electro-)catalytical applications N2 - Wastewaters containing high concentrations of NH4+, PO43- and transition metals are environmentally harmful and toxic pollutants. At the same time phosphorous and transition metals constitute valuable resources. Here, we report the synthesis routes for Co- and Ni-struvites (NH4MPO4∙6H2O, M = Ni2+, Co2+) out of aqueous solutions resembling synthetic/industrial waste water compositions, and allowing for P, ammonia and metal co-precipitation. Furthermore, the as-obtained struvites were further up-cycled. When heated, these transition metal phosphates (TMPs) demonstrate significant changes in the degree of crystallinity/coordination environment involving a high amount of amorphous phases and importantly develop mesoporosity (Figure 1). In this regard, amorphous and mesoporous TMPs are known to be highly promising (electro-)catalysts. Amorphous phases do not represent a simple “disordered” crystal but more a complex system with a broad range of compositions and physicochemical properties, which remain mostly unknown. Consequently, we investigated the recrystallization and amorphization process during thermal treatment and a resolved the complex amorphous/crystalline structures (Figure 2). As a proof-of-principle for their applicational use, the as-obtained TMPs demonstrate significant proton conductivity properties similar to apatite-like structures from room to high temperatures (>800°C). Hence, we have developed a promising recycling route in which environmental harmful contaminants like PO43-, NH4+ and 3d metals would be extracted out of waste waters in the form of precursor raw materials. These raw materials can be then further up-cycled through a simple thermal treatment for their specific application in electrocatalysis. T2 - Goldschmidt Conference 2022 CY - Hawai'i, USA DA - 10.07.2022 KW - Mesoporosity KW - Amorphous phases KW - Transition metals KW - Struvite KW - Phosphates PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-552852 UR - https://conf.goldschmidt.info/goldschmidt/2022/meetingapp.cgi/Paper/9501 AN - OPUS4-55285 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael T1 - Already Producing or Still Calibrating? – Advances of Model-Based Data Evaluation Concepts for Quantitative Online NMR Spectroscopy N2 - The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors simplify their use and enable plug-and-play integration, even though they may appear to be more complex at first sight. Monitoring specific information (i.e., “chemical” such as physico-chemical properties, chemical reactions, etc.) is the key to “chemical” process control. Here we introduce our smart online NMR sensor module provided in an explosion proof housing as example. Due to NMR spectroscopy as an “absolute analytical comparison method”, independent of the matrix, it runs with extremely short set-up times in combination with “modular” spectral models. Such models can simply be built upon pure component NMR spectra within a few hours (i.e., assignment of the NMR signals to the components) instead of tedious calibrations runs. We present a range of approaches for the automated spectra analysis moving from statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). Based on concentration measurements of reagents and products by the NMR analyzer a continuous production and direct loop process control were successfully realized for several validation runs in a modular industrial pilot plant and compared to conventional analytical methods (HPLC, near infrared spectroscopy). The NMR analyser was developed for an intensified industrial process funded by the EU’s Horizon 2020 research and innovation programme (“Integrated CONtrol and SENsing”, www.consens-spire.eu). T2 - Practical Applications of NMR in Industry Conference (PANIC) 2018 CY - La Jolla, California, USA DA - 04.03.2018 KW - Process Monitoring KW - Process Control KW - Process analytical technology KW - Spectral Modeling KW - Smart Sensors KW - CONSENS KW - Industrie 4.0 PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-444357 AN - OPUS4-44435 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon T1 - Novel Flow Cell Designs for Process Monitoring with Compact NMR Spectroscopy N2 - Compact nuclear magnetic resonance (NMR) instruments make NMR spectroscopy and relaxometry accessible in industrial and harsh environments for reaction characterization and process control. Robust field integration of NMR systems have to face explosion protection or integration into process control systems with short set-up times. This paves the way for industrial automation in real process environments. The design of failsafe, temperature and pressure resistant flow through cells along with their NMR-specific requirements is an essential cornerstone to enter industrial production plants and fulfill explosion safety requirements. Additionally, if fast reactions are monitored, suitable mixing devices need to be placed in close vicinity to the measuring volume to mix the reactants properly. NMR-specific requirements aim at full quantitative pre-magnetization and acquisition with maximum sensitivity while reducing sample transfer times and dwell-times. All parameters are individually dependent on the applied NMR instrument. Luckily, an increasing number of applications are reported together with an increasing variety of commercial equipment. However, these contributions have to be reviewed thoroughly. The performance of sample flow cells commonly used in online analytics and especially for low-field NMR spectroscopy was experimentally and theoretically investigated by 1H-NMR experiments and numerical simulations. Especially, the applicability of 3D printed zirconium dioxide for innovative flow cell designs was of interest. Here, we demonstrate and discuss an automated test method to determine the critical parameters of flow through cells for quantitative online NMR spectroscopy. The setup is based on randomized setpoints of flow rates in order to reduce temperature related effects. Five flow cells and tubing were assessed and compared for high-field as well as low-field NMR spectrometers. T2 - Practical Applications of NMR in Industry Conference ​(PANIC) 2018 CY - La Jolla, California, USA DA - 04.03.2018 KW - Process Monitoring KW - Process Control KW - Flow Cell KW - Online NMR Spectroscopy KW - Additive Manufacturing KW - CONSENS PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-444364 N1 - Geburtsname von Bornemann-Pfeiffer, Martin: Bornemann, M. - Birth name of Bornemann-Pfeiffer, Martin: Bornemann, M. AN - OPUS4-44436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wander, Lukas T1 - Keramikdurchflusszellen für das industrielle Reaktionsmonitoring mit Niederfeld-NMR-Spektroskopie N2 - Derzeit verfügbare Niederfeld-NMR-Spektrometer sind oft für Laborapplikationen konzipiert. Für den Einsatz im industriellen Prozessmonitoring müssen deshalb Anpassungen vorgenommen werden. Ein wichtiger Aspekt ist die Gestaltung der Messzelle. Sie muss über eine hohe thermische-, chemische und vor allem mechanische Beständigkeit verfügen. Hinzu kommt die Besonderheit des NMR-Experiments, das auf die Durchlässigkeit von Radiofrequenzen angewiesen ist. Keramik ist ein in der Hochfeld-NMR-Spektroskopie bewährtes Material das diese Eigenschaften vereint. Um im Prozessmonitoring die Interessen kleiner Bypass-Volumina, großer Durchflussgeschwindigkeit und großes Signal-zu-Rausch-Verhältnis mit der nötigen Vormagnetisierungszeit in Einklang zu bringen, ist eine im Messbereich aufgeweitete Zellgeometrie vorteilhaft. Die Fertigung einer Keramikmesszelle für die Niederfeld-NMR-Spektroskopie für Drücke bis 7 MPa mit dieser besonderen Geometrie wurde mit Hilfe eines modernen additiven Fertigungsverfahrens realisiert. Quantitative NMR-Messungen an konstant durch das Spektrometer strömenden Flüssigkeiten werden durch eine maximale Durchflussgeschwindigkeit limitiert. Diese wird von vielen Einflussgrößen bestimmt und sollte vor jeder quantitativen Messreihe experimentell für das individuelle System ermittelt werden. Zu diesem Zweck wurde eine automatisierte Laboranordnung konzipiert. Der Vergleich der neuen NMR-Keramikzelle mit bestehenden Messzellen u. a. anhand dieses Parameters untermauert ihre Eignung für das industrielle Prozessmonitoring. T2 - 13. Herbstkolloquium Arbeitskreis Prozessanalytik CY - Esslingen, Germany DA - 20.11.2017 KW - Keramikdurchflusszelle KW - Niederfeld-NMR KW - Online-NMR PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-430918 AN - OPUS4-43091 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon T1 - Simple calibration concept of an online NMR module demonstrated in a modularised production plant N2 - Monitoring specific information (such as physico-chemical properties, chemical re-actions, etc.) is the key to chemical process control. Within the CONSENS Project, the challenge to adapt a commercially available benchtop NMR spectrometer to the full requirements of an automated chemical production environment was tack-led. The developed online NMR module was provided in an explosion proof housing and involves a compact 43.5 MHz NMR spectrometer together with an acquisition unit, a programmable logic controller for automated triggering, flow con-trol, as well as data communication. First results of an aromatic coupling reaction in lab scale showed a general feasibil-ity according to the signal information in the acquired NMR spectra even though with a considerable overlap. Due to the comparatively low field strength of the NMR spectrometer multivariate methods had to be considered for the prediction of con-centration profiles based on spectral data. Typically, for industrial application of those methods, e.g. Partial Least Squares Regression (PLS-R) as well as Indirect Hard Modeling, large amount of calibration data is demanded, which must be ac-quired in time consuming lab-scale experiments and offline analytics. When it comes to changes in raw materials (e.g., varying functional groups, additional stabi-lizing agents) calibration experiments and data evaluation models are developed again. Here we present an approach of automated data analysis tools for low field NMR spectra with minimal calibration effort. The algorithms are based on Indirect Hard Modeling, whereby each component in each mixture spectra can be rep-resented by several flexible peak functions (pure component models). This means, that only pure component NMR spectra are needed to generate a first evaluation model. The flexibility of peak functions in the spectral model can be adjusted via constraints of peak parameters. The area of any pure component model can either be converted to concentrations based on a one-point calibration on raw material concentration or even neat solvent signals. In several cases it has been shown, the IHM works almost independently of the matrix of the real samples. Such a calibration can be repeated daily in the beginning of each process run with minimal time effort. Moreover, additional pure components can be added to the model or even substitut-ed while keeping the previously adjusted peak function constraints. The proposed method exhibited good agreement of resulting concentration data from low field NMR spectra, when compared to an online high field NMR spectrometer as refer-ence instrument. T2 - 13. Kolloquium des Arbeitskreises Prozessanalytik der DECHEMA und der GDCh-Fachgruppe Analytische Chemie CY - Esslingen, Germany DA - 20.11.2017 KW - Online monitoring KW - Online NMR spectroscopy KW - Modularised production PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-430999 AN - OPUS4-43099 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kunji Purayil, Sruthi Krishna T1 - Physics-Based Model Assisted Age Prediction of Real- Serviced Thermal Barrier Coated Samples Using Infrared Thermography N2 - In this study, an age prediction model is developed for the real serviced thermal barrier coated (TBC) samples. TBC is a multilayer coating applied on metallic structures exposed to high temperatures, such as gas turbine blades and aeroengine parts, to extend the operational life. One of the main challenges for developing an age prediction model is the unavailability of serviced samples and labelled datasets. So, in this study, experimentally validated numerical models are used for data generation. The study considers samples with three different service times, i.e., 0 (newly coated), 500 hours, and 1000 hours. The age prediction is done in two stages: thermal diffusivity prediction for blind real serviced samples with a trained 1D-CNN model and classification of samples based on the service hours into different classes using AI classification models. The results demonstrate that our approach provides reliable age estimations with a high correlation between actual and predicted ages of samples. This method provides a non-destructive, efficient, and accurate method of evaluating the life of TBCs, which is a substantial improvement over traditional techniques that rely on complex destructive methods or microstructural analysis for the age evaluation. T2 - 17th Quantitative InfraRed Thermography Conference (QIRT) CY - Zagreb, Croatia DA - 01.07.2024 KW - Infrared Thermography KW - NDE 4.0 KW - AI for NDT KW - Thermal barrier coatings PY - 2024 AN - OPUS4-62450 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klewe, Tim T1 - Feuchtemessung an Fußböden mit Radar und Neutronensonde – Ein Vergleich von Labor und Praxis N2 - Nach Auftreten eines Feuchteschadens in Fußbodenaufbauten sind sowohl die zeitnahe Feststellung als auch Eingrenzung betroffener Bereiche von besonderer Bedeutung. So können erforderliche Renovierungsmaßnahmen effizient geplant und mögliche Folgeschäden vermieden werden. Zur messtechnischen Beantwortung dieser Fragestellungen werden bereits seit vielen Jahren Neutronensonden eingesetzt, welche allerdings keine Tiefenzuordnung des schadensträchtigen Flüssigwassers zulassen. Hierzu müssen mit hohem zeitlichem und finanziellem Aufwand zerstörende Sondierungsbohrungen vorgenommen werden, welche zukünftig durch den parallelen Einsatz des Radarverfahrens vermieden werden könnten. In systematischen Laborstudien wurden gängige Feuchteschäden an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf das Messsignal untersucht. Hierbei kamen Zementund Anhydritestriche, sowie die Dämmmaterialen Styropor, Styrodur, Glaswolle und Perlite-Schüttung mit variierenden Schichtdicken zum Einsatz, um die vielfältigen Konfigurationen der Praxis abzubilden. Für den gewonnenen Datensatz konnten geeignete Signalmerkmale extrahiert werden, welche mithilfe multivariater Datenauswertung eine Klassifizierung des vorliegenden Schadenfalls zulassen. Zum Ende des Forschungsvorhabens steht besonders die Anwendbarkeit der entwickelten Methoden für die Praxis im Fokus. Hierzu wurden Messungen an realen Schadensfällen durchgeführt und deren Ergebnisse mit den Laboruntersuchungen verglichen. Hierbei stellten sich variierende Schichtdicken, sowie vorkommende Fußbodenheizungen und Armierungsgitter als mögliche Fehlerquellen für eine vollständig automatisierte Auswertung heraus. T2 - 81. Jahrestagung der Deutschen Geophysikalischen Gesellschaft (DGG) CY - Online meeting DA - 01.03.2021 KW - Radar KW - Feuchte KW - Fußboden KW - Neutronensonde PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-522227 DO - https://doi.org/10.23689/fidgeo-3955 AN - OPUS4-52222 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klewe, Tim T1 - Signalmerkmale des Radarverfahrens zur Klassifizierung von Feuchteschäden in Fußbodenaufbauten N2 - Zur Eingrenzung und Klassifizierung auftretender Feuchteschäden in geschichteten Fußbodenaufbauten wird bereits seit vielen Jahren das Neutronensondenverfahren eingesetzt. Während eine Eingrenzung des Schadens bereits durch die zerstörungsfrei aufgenommenen Messdaten möglich ist, erfordert die Klassifizierung zeit- und kostenintensive Sondierungsbohrungen. Die somit gewonnenen Tiefeninformationen zur Lage des Flüssigwassers tragen maßgeblich zur Planung der erforderlichen Reparaturarbeiten bei, was die Frage nach einer zerstörungsfreien Alternative zur vertikalen Lokalisierung von Feuchte in Fußböden stellt. Das Radarverfahren ist mit seiner hohen Sensitivität für Wasser besonders geeignet und soll künftig zur automatisierten Klassifizierung typischer Schadensfälle beitragen. In einem laufenden Forschungsvorhaben werden in systematischen Laborstudien gängige Schadensfälle an häufig anzutreffenden Fußbodenaufbauten simuliert und deren Einfluss auf die genannten Verfahren untersucht. Hierbei kommen Zement- und Anhydritestriche, sowie unterschiedliche Dämmmaterialen mit variierenden Schichtdicken zum Einsatz. Wesentlicher Bestandteil der Auswertung ist die Extraktion signifikanter Signalmerkmale des Radarverfahrens, welche Rückschlüsse auf den Schadensfall und ggf. die Wassermenge zulassen. Die Robustheit gegenüber unterschiedlichsten Aufbauten mit wechselnden Schichtdicken und Materialien steht hierbei besonders im Fokus. Erste Ergebnisse empfehlen die Betrachtung der örtlichen Verteilung bestimmter Signalmerkmale im Radargramm (B-Scan), um eine Klassifizierung der Schadensfälle vornehmen zu können. T2 - Fachtagung Bauwerksdiagnose 2020 CY - Berlin, Germany DA - 13.02.2020 KW - Radar KW - Feuchte KW - Signalmerkmale KW - Klassifikation PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-504143 AN - OPUS4-50414 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Munsch, Sarah Mandy T1 - Ermittlung der Oberflächenrelaxivität in Sandsteinen - ein Methodenvergleich N2 - Mit dem zerstörungsfreien Verfahren der nuklear magnetischen Resonanz (NMR) mit Fokus auf 1H-Protonen lässt sich der Feuchtegehalt in porösen Materialien bestimmen und bei einem vollgesättigten Medium eine Porengrößenverteilung ableiten. Für die Ermittlung der Porengrößenverteilung muss die gemessene T2-Relaxationszeitenverteilung mit dem Parameter Oberflächenrelaxivität (OR) umgerechnet werden. Ist dieser Parameter für das zu untersuchende Medium unbekannt, kann dieser mithilfe von Vergleichsverfahren abgeschätzt werden. Dabei kommen z. B. Gassorption, Quecksilberporosimetrie (MIP), Dünnschliff-Mikroskopie oder µ-Computer-Tomographie (µ-CT) zum Einsatz. Da die verschiedenen Verfahren allerdings unterschiedliche Auflösungsgrenzen aufweisen und auf verschiedenen physikalischen Prinzipien beruhen, können die ermittelten ORs für ein Medium stark variieren. Um ein besseres Verständnis für die OR und die Einflüsse der Vergleichsverfahren zu bekommen, wurden 19 verschiedene Sandsteintypen untersucht. Die OR wurde zum einen basierend auf der spezifischen inneren Oberfläche aus der dynamischen Dampfsorption (DVS) und der Gassorption abgeleitet. Zum anderen wurden die Relaxationszeitenverteilungen durch manuelles Anpassen der OR derart in Porengrößenverteilungen umgerechnet, sodass es eine Übereinstimmung mit den Porengrößenverteilungen aus MIP und/oder µ-CT gibt. Die Umrechnung von Relaxationszeitverteilungen in eine Porengrößenverteilung berücksichtigt dabei sowohl fast- als auch slow-diffusion. Insgesamt ergab sich für die Sandsteine ein breites Spektrum an ORs, bei dem die über die innere spezifische Oberfläche ermittelten ORs andere Größenordnungen aufwiesen (< 10 µm/s), als bei dem Vergleich mit MIP oder µ-CT (bis 600 µm/s). Die mit MIP und µ-CT ermittelten Werten lagen dabei um einen Faktor von 1 bis 30 auseinander. Dieser umfangreiche Datensatz, der vier verschiedene Vergleichsverfahren einbezieht, soll neue Erkenntnisse in der Charakterisierung von porösen Materialien (z. B. bezüglich der Oberflächenrauigkeit) und in der Ursache für die starke Variation der OR ermöglichen. Durch das Berücksichtigen von fast- als auch slow-diffusion, können dabei sogar Daten in eine Porengrößenverteilung umgerechnet werden, bei denen das fast-diffusion-Kriterium nach Brownstein und Tarr nicht erfüllt ist. Außerdem ergibt sich aus der Berücksichtigung des slow-diffusion-Regimes ein neues Verständnis für die obere Auflösungsgrenze von NMR. T2 - 82. Jahrestagung der Deutschen Geophysikalischen Gesellschaft CY - Online meeting DA - 07.03.2022 KW - NMR KW - Sandsteine KW - Oberflächenrelaxivität KW - Porengrößenverteilung PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-544721 UR - https://e-docs.geo-leo.de/handle/11858/9672 DO - https://doi.org/10.23689/fidgeo-5330 AN - OPUS4-54472 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Munsch, Sarah Mandy T1 - Möglichkeiten und Grenzen der zerstörungsfreien Erfassung niedriger Feuchtegehalte in teilgesättigten Sandsteinen mit 1H-NMR N2 - Die zerstörungsfreie Ermittlung der Materialfeuchte in Baustoffen ist für das Bauwesen von großer Bedeutung, denn ein erhöhter Feuchteeintrag kann zu Schimmelbildung, Alkali-Kieselsäure-Reaktionen, Korrosion etc. führen und somit ein hohes Schadenspotential mit sich bringen. Auch wenn zur qualitativen Lokalisierung möglicher Schad- und Risikostellen bereits zahlreiche zerstörungsfreie Verfahren in der Praxis Anwendung finden, besteht ein Mangel an quantitativen Verfahren, die auch bei niedrigen Feuchtegehalten sensitiv sind. Eine Methode zur zerstörungsfreien und quantitativen Bestimmung des Feuchtegehaltes und der effektiven Porosität ist die 1H-Kernspinresonzanzmethode (NMR). Da NMR sensitiv für die molekulare Beweglichkeit von Wasserstoffprotonen ist, lassen sich Informationen über die Bindungsform und -stärke sowie der Umgebung (Porengröße und Mineralzusammensetzung) der Wasserstoffprotonen gewinnen. Obwohl es bereits seit über 20 Jahren mobile NMR-Messeräte gibt, wird NMR heutzutage immer noch weitestgehend im Labor eingesetzt. Dies liegt daran, dass sie aufgrund der verwendeten Permanentmagnete schwer sind und nur äußerst geringe Eindringtiefen ermöglichen. In einer derzeit laufenden Forschungsarbeit wird deshalb ein speziell für Bohrkerne entworfener NMR-Tomograph eingesetzt. Mit seiner minimalen Echozeit von 50 µs lässt sich (abhängig von der Oberflächenrelaxivität) Wasser bis in nanometergroßen Poren erfassen. Um die Sensitivität von NMR bei Teilsättigung zu untersuchen, wurden verschiedene Sandsteinproben in Exsikkatoren mit relativen Luftfeuchten im Bereich von 33 % bis 96 % gelagert. Als Referenzen dienen zum einen das NMR-Signal bei Vollsättigung und zum anderen die Porengrößenverteilung aus Quecksilberporosimetriemessungen (MIP). Um die NMR-Sensitivität zu bewerten, wird die Korrelation der NMR-Amplitude mit den gravimetrisch ermittelten Feuchtegehalten sowie ein Vergleich der Porosität aus NMR und MIP betrachtet. Zu beachten ist in diesem Zusammenhang, dass sowohl die Reduzierung der Wasserfilmdicke als auch die Verkleinerung von Porengrößen zu einer ähnlichen Verkürzung der T2-Relaxationszeit führt. Als Ausblick wird ein Lösungsansatz vorgestellt, bei dem die NMR-Signale mit der Wasserfilmdickenberechnung basierend auf der relativen Luftfeuchte im Material korreliert werden. T2 - 81. Jahrestagung der Deutschen Geophysikalischen Gesellschaft CY - Online meeting DA - 01.03.2021 KW - NMR KW - Sandsteine KW - Porosität KW - Oberflächenrelaxivität KW - Feuchtegehalt PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-522271 DO - https://doi.org/10.23689/fidgeo-3957 N1 - Geburtsname von Munsch, Sarah Mandy: Nagel, S. M. - Birth name of Munsch, Sarah Mandy: Nagel, S. M. AN - OPUS4-52227 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Munsch, Sarah Mandy T1 - Zerstörungsfreie Feuchtebestimmung und Porengrößenabschätzung an Estrichen mittels NMR N2 - Nuklear magnetische Resonanz (NMR) etabliert sich zunehmend im Bauingenieurwesen als eine alternative Methode zur zerstörungsfreien Feuchtebestimmung in Baustoffen. Schäden, die durch einen zu hohen Anteil an Flüssigwasser auftreten können, sind Ablösungen, Korrosion, Frostschäden, Induktion von Salzkristallisationen, etc. Aufgrund der Sensitivität für 1H-Protonen, ist NMR eine geeignete Methode zur Feuchtedetektion. Dabei kann laut Theorie zwischen frei, chemisch oder physikalisch gebundenem Wasser differenziert werden, während in der Praxis abhängig von der Messtechnik und Probengröße größtenteils nur das freie Wasser detektierbar ist. Mithilfe der NMR Relaxometrie lassen sich nicht nur Relaxationsabklingkurven ermitteln, sondern auch Relaxationszeitenverteilungen, sowie bei Vollsättigung ggf. eine Porengrößenverteilung ableiten. Darüber hinaus lassen sich erste Annahmen über die Entwicklung der Porensättigung bei Teilsättigung der Probe treffen. Ziel dieser Arbeit war die Untersuchung der zeitlichen Entwicklung der Porensättigung während des natürlichen Trocknungsprozesses (Teilsättigung) sowie die Ermittlung der Porengrößenverteilung an Beispiel von zementgebundenen Estrichen. Für den Versuch wurden zwei zementgebundene Estrichproben nach abgeschlossener Hydratation wieder aufgesättigt. Während des anschließenden natürlichen Trocknungsprozesses wurden regelmäßig NMR-Messungen durchgeführt sowie die Massenentwicklung observiert. Hauptfokus lag auf der zeitlichen und tiefenabhängigen Entwicklung der Relaxationszeitenverteilungen. Bei fortschreitender Trocknung der Proben konnte eine Verschiebung des Maximums der Relaxationszeitenverteilung zu kleineren Zeiten beobachtet werden. Die Ursache liegt zum einen in dem abnehmenden Anteil an freiem Wasser in größeren Poren und zum anderen in dem verhältnismäßig zunehmenden Signalanteil durch Wasser in kleineren Poren. Durch den Vergleich mit Quecksilberporosimetrie und Gas-Adsorptions-Ergebnissen, konnte aus den NMR-Daten eine unimodale Porengrößenverteilung mit einer dominanten Porengröße von 0,08 bis 0,1 µm und eine effektive Oberflächenrelaxivität von ca. 10 bis 30 µm/s abgeleitet werden. T2 - Bauwerksdiagnose 2018 CY - Berlin, Germany DA - 15.02.2018 KW - Estrich KW - Feuchte KW - NMR KW - Porengrößen KW - Relaxometrie PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-468966 UR - https://www.bauwerksdiagnose2018.de/Portals/bauwerksdiagnose2018/P/p11.pdf N1 - Geburtsname von Munsch, Sarah Mandy: Nagel, S. M. - Birth name of Munsch, Sarah Mandy: Nagel, S. M. AN - OPUS4-46896 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -