TY - JOUR
A1 - Baláž, Matej
A1 - Birinci, Mustafa
A1 - Şentürk, Kader
A1 - Achimovičová, Marcela
A1 - Baláž, Peter
A1 - Tampubolon, Imelda Octa
A1 - Stolar, Tomislav
A1 - Bienert, Ralf
A1 - Emmerling, Franziska
A1 - Erdemoğlu, Sema
A1 - Sis, Hikmet
A1 - Erdemoğlu, Murat
T1 - Utilizing Taguchi method and in situ X-ray powder diffraction monitoring to determine the influence of mechanical activation conditions on the physico-chemical properties and Al leachability of K-feldspar
N2 - K-feldspar represents an important natural resource of potassium and aluminum. Within the framework of this study, the K-feldspar was mechanically activated in a planetary ball mill under different conditions planned according to 43 Taguchi orthogonal array experimental design. As outputs, specific surface area (SBET), median particle size (d50), amorphization degree of mineral phases , and Al recovery were used. It was found that the initial d50 value of 293 μm could be reduced to 6.7 μm and the SBET value of 4.7 m2/g could be increased up to 32.5 m2/g upon milling. Both microcline KAl3SiO8, and albite NaAl3SiO8 could be almost completely amorphized, whereas quartz SiO2 still maintained some crystallinity even under the most intensive conditions. Increasing SBET and decreasing the d50 values did not lead to a significant improvement in Al leach recovery, whereas a clear relationship between the amorphization of microcline and the recovered aluminum was found. Analysis of Variance (ANOVA) showed that increasing ball-to-powder ratio is the most beneficial for the improvement in Al recovery. In situ powder X-ray diffraction monitoring performed in an oscillation ball mill under synchrotron irradiation has shown very rapid amorphization of microcline phase at the beginning. However, amorphization of microcline was only partial after two hours of the treatment in this mill, apart from almost complete process in the planetary ball mill. In the end, regressions for the calculation of Al recovery by knowing the values of input parameters were calculated. In general, by just using mechanical activation without the subsequent roasting process that is commonly used to boost metal recoveries, it was possible to quantitatively recover aluminum from K-feldspar.
KW - Mechanochemistry
KW - Mechanical activation
KW - Design of experiments
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-611059
DO - https://doi.org/10.1016/j.jmrt.2024.08.156
SN - 2238-7854
VL - 32
SP - 3886
EP - 3895
PB - Elsevier B.V.
AN - OPUS4-61105
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Cakir, Cafer Tufan
A1 - Bogoclu, Can
A1 - Emmerling, Franziska
A1 - Streli, Christina
A1 - de Oliveira Guilherme Buzanich, Ana
A1 - Radtke, Martin
T1 - Machine learning for efficient grazing-exit x-ray absorption near edge structure spectroscopy analysis: Bayesian optimization approach
N2 - In materials science, traditional techniques for analyzing layered structures are essential for obtaining information about local structure, electronic properties and chemical states. While valuable, these methods often require high vacuum environments and have limited depth profiling capabilities. The grazing exit x-ray absorption near-edge structure (GE-XANES) technique addresses these limitations by providing depth-resolved insight at ambient conditions, facilitating in situ material analysis without special sample preparation. However, GE-XANES is limited by long data acquisition times, which hinders its practicality for various applications. To overcome this, we have incorporated Bayesian optimization (BO) into the GE-XANES data acquisition process. This innovative approach potentially reduces measurement time by a factor of 50. We have used a standard GE-XANES experiment, which serve as reference, to validate the effectiveness and accuracy of the BO-informed experimental setup. Our results show that this optimized approach maintains data quality while significantly improving efficiency, making GE-XANES more accessible to a wider range of materials science applications.
KW - Machine Learning
KW - GE-XANES
KW - Bayesian Optimization
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-603955
DO - https://doi.org/10.1088/2632-2153/ad4253
VL - 5
IS - 2
SP - 1
EP - 12
PB - IOP Publishing
AN - OPUS4-60395
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Dittmar, Stefan
A1 - Ruhl, Aki S.
A1 - Altmann, Korinna
A1 - Jekel, Martin
T1 - Settling Velocities of Small Microplastic Fragments and Fibers
N2 - There is only sparse empirical data on the settling velocity of small, non-buoyant microplastics thus far, although it is an important parameter governing their vertical transport within aquatic environments. This study reports the settling velocities of 4031 exemplary microplastic particles. Focusing on the environmentally most prevalent particle shapes, irregular microplastic fragments of four different polymer types (9–289 µm) as well as five discrete length fractions (50–600 µm) of common nylon and polyester fibers were investigated, respectively. All settling experiments were carried out in quiescent water using a specialized optical imaging setup. The method has been previously validated in order to minimize disruptive factors, e.g. thermal convection or particle interactions, and thus enable the precise measurements of the velocities of individual microplastic particles (0.003–9.094 mm/s). Based on the obtained data, ten existing models for predicting a particle’s terminal settling velocity were assessed. It is concluded that models, which were specifically deduced from empirical data on larger microplastics, fail to provide accurate predictions for small microplastics. Instead, a different approach is highlighted as a viable option for computing settling velocities across the microplastics continuum in terms of size, density and shape.
KW - Microplastics
KW - Microplastic fibers
KW - Settling velocity
KW - Sinking velocity
KW - Sedimentation
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597455
DO - https://doi.org/10.1021/acs.est.3c09602
SN - 0013-936X
VL - 58
IS - 14
SP - 6359
EP - 6369
PB - American Chemical Society (ACS)
AN - OPUS4-59745
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Coburger, Peter
A1 - de Oliveira Guilherme Buzanich, Ana
A1 - Emmerling, Franziska
A1 - Abbenseth, Josh
T1 - Combining geometric constraint and redox non-innocence within an ambiphilic PBiP pincer ligand
N2 - The first pincer ligand featuring a strictly T-shaped pnictogen donor moiety was synthesised. The PBiP ligand's redox activity facilitates unprecedented ambiphilic bonding of the Bi centre with transition metals through the Bi(6p) orbital.
KW - EXAFS
KW - Pincer Ligand
KW - Group 15 metals
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-611113
DO - https://doi.org/10.1039/D4SC00197D
SN - 2041-6520
SP - 1
EP - 8
PB - Royal Society of Chemistry (RSC)
AN - OPUS4-61111
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Schlögl, Johanna
A1 - Goldammer, Ole
A1 - Bader, Julia
A1 - Emmerling, Franziska
A1 - Riedel, Sebastian
T1 - Introducing AFS ([Al(SO3F)3]x) – a thermally stable, readily available, and catalytically active solid Lewis superacid
N2 - This paper introduces the thermally stable, solid Lewis superacid aluminium tris(fluorosulfate) (AFS), that is easy-to-synthesize from commercially available starting materials. Its applicability, e.g. in catalytic C–F bond activations, is shown.
KW - Lewis Acid
KW - C-F activation
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-601001
DO - https://doi.org/10.1039/D4SC01753F
SN - 2041-6520
SP - 1
EP - 7
PB - Royal Society of Chemistry (RSC)
AN - OPUS4-60100
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Senges, Gene
A1 - de Oliveira Guilherme Buzanich, Ana
A1 - Lindič, Tilen
A1 - Gully, Tyler A.
A1 - Winter, Marlon
A1 - Radtke, Martin
A1 - Röder, Bettina
A1 - Steinhauer, Simon
A1 - Paulus, Beate
A1 - Emmerling, Franziska
A1 - Riedel, Sebastian
T1 - Unravelling highly oxidized nickel centers in the anodic black film formed during the Simons process by in situ X-ray absorption near edge structure spectroscopy
N2 - The electrofluorination after Simons has been used for the last century to produce everyday life materials. An in situ XANES investigation of the controversially debated black film apparent in the Simons process revealed high-valent nickel centers.
KW - Synchrotron
KW - BAMline
KW - XANES
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-608366
DO - https://doi.org/10.1039/d3sc06081k
SN - 2041-6520
VL - 15
IS - 12
SP - 4504
EP - 4509
PB - Royal Society of Chemistry (RSC)
AN - OPUS4-60836
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Das, Prasenjit
A1 - Chakraborty, Gouri
A1 - Friese, Nico
A1 - Roeser, Jérôme
A1 - Prinz, Carsten
A1 - Emmerling, Franziska
A1 - Schmidt, Johannes
A1 - Thomas, Arne
T1 - Heteropolyaromatic Covalent Organic Frameworks via One-Pot Multicomponent Reactions
N2 - Multicomponent reactions (MCRs) offer a platform to create different chemical structures and linkages for highly stable covalent organic frameworks (COFs). As an illustrative example, the multicomponent Povarov reaction generates 2,4-phenylquinoline from aldehydes and amines in the presence of electron-rich alkenes. In this study, we introduce a new domino reaction to generate unprecedented 2,3-phenylquinoline COFs in the presence of epoxystyrene. This work thus presents, for the first time, structural isomeric COFs produced by multicomponent domino and Povarov reactions. Furthermore, 2,3-phenylquinolines can undergo a Scholl reaction to form extended aromatic linkages. With this approach, we synthesize two thermally and chemically stable MCR-COFs and two heteropolyaromatic COFs using both domino and in situ domino and Scholl reactions. The structure and properties of these COFs are compared with the corresponding 2,4-phenylquinoline-linked COF and imine-COF, and their activity toward benzene and cyclohexane sorption and separation is investigated. The position of the pendant phenyl groups within the COF pore plays a crucial role in facilitating the industrially important sorption and separation of benzene over cyclohexane. This study opens a new avenue to construct heteropolyaromatic COFs via MCR reactions.
KW - COF
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-604038
DO - https://doi.org/10.1021/jacs.4c02551
SP - 1
EP - 9
PB - American Chemical Society (ACS)
AN - OPUS4-60403
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Wiesner, Yosri
A1 - Hoffmann, Thomas
A1 - Range, David
A1 - Altmann, Korinna
T1 - Microplastics in sediments of the river Rhine—A workflow for preparation and analysis of sediment samples from aquatic river systems for monitoring purposes
N2 - AbstractMicroplastics (MP) can be detected in all environmental systems. Marine and terrestrial aquatic systems, especially the transported suspended solids, have often been the focus of scientific investigations in the past. Sediments of aquatic river systems, on the other hand, were often ignored due to the time‐consuming sample preparation and analysis procedures. Spectroscopic measurement methods counting particle numbers are hardly suitable as detection methods, because there are plenty of natural particles next to a small number of MP particles. Integral methods, such as thermoanalytical methods are determining the particle mass independently of the inorganic components.In this study, a workflow for sample preparation via density separation and subsequent analysis by thermal extraction desorption‐gas chromatography/mass spectrometry is presented, which leads to representative and homogeneous samples and allows fast and robust MP mass content measurements suitable for routine analysis. Polymers were identified and quantified in all samples. Polyethylene and styrene‐butadiene rubber are the dominant polymers, besides polypropylene and polystyrene. Overall, total polymer masses between 1.18 and 337.0 µg/g could be determined. Highest MP concentrations in riverbed sediment are found in sites characterized by low flow velocities in harbors and reservoirs, while MP concentrations in sandy/gravelly bed sediments with higher flow velocities are small.
KW - Microplastics
KW - Density separation
KW - TED-GC/MS
KW - NaI
PY - 2023
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597335
DO - https://doi.org/10.1002/appl.202200125
VL - 3
IS - 2
SP - 1
EP - 10
PB - Wiley VHC-Verlag
AN - OPUS4-59733
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Fischer, Janina
A1 - Kaufmann, Jan Ole
A1 - Weller, Michael G.
T1 - Simple Determination of Affinity Constants of Antibodies by Competitive Immunoassays
N2 - The affinity constant, also known as the equilibrium constant, binding constant, equilibrium association constant, or the reciprocal value, the equilibrium dissociation constant (Kd), can be considered as one of the most important characteristics for any antibody–antigen pair. Many methods based on different technologies have been proposed and used to determine this value. However, since a very large number of publications and commercial datasheets do not include this information, significant obstacles in performing such measurements seem to exist. In other cases where such data are reported, the results have often proved to be unreliable. This situation may indicate that most of the technologies available today require a high level of expertise and effort that does not seem to be available in many laboratories. In this paper, we present a simple approach based on standard immunoassay technology that is easy and quick to perform. It relies on the effect that the molar IC50 approaches the Kd value in the case of infinitely small concentrations of the reagents. A two-dimensional dilution of the reagents leads to an asymptotic convergence to Kd. The approach has some similarity to the well-known checkerboard titration used for the optimization of immunoassays. A well-known antibody against the FLAG peptide, clone M2, was used as a model system and the results were compared with other methods. This approach could be used in any case where a competitive assay is available or can be developed. The determination of an affinity constant should belong to the crucial parameters in any quality control of antibody-related products and assays and should be mandatory in papers using immunochemical protocols.
N2 - Die Affinitätskonstante, auch bekannt als Gleichgewichtskonstante, Bindungskonstante, Gleichgewichtsassoziationskonstante oder der reziproke Wert, die Gleichgewichtsdissoziationskonstante (Kd), kann als eine der wichtigsten Eigenschaften für jedes Antikörper-Antigen-Paar angesehen werden. Zur Bestimmung dieses Wertes wurden zahlreiche Methoden auf der Grundlage verschiedener Technologien vorgeschlagen und verwendet. Da jedoch eine sehr große Anzahl von Veröffentlichungen und kommerziellen Datenblätter diese Information nicht enthalten, scheint es erhebliche Hindernisse bei der Durchführung solcher Messungen zu geben. In anderen Fällen, in denen solche Daten angegeben werden, haben sich die Ergebnisse häufig als unzuverlässig erwiesen. Diese Situation könnte darauf hindeuten, dass die meisten der heute verfügbaren Technologien ein hohes Maß an Fachwissen und Aufwand erfordern, das in vielen Labors nicht vorhanden zu sein scheint. In diesem Beitrag stellen wir einen einfachen Ansatz vor, der auf der Standard-Immunoassay-Technologie basiert und einfach und schnell durchführbar ist. Er beruht auf dem Effekt, dass sich der molare IC50 bei unendlich kleinen Reagenz-Konzentrationen dem Kd-Wert annähert. Eine zweidimensionale Verdünnung der Reagenzien führt zu einer asymptotischen Konvergenz zu Kd. Der Ansatz hat eine gewisse Ähnlichkeit mit der bekannten Checkerboard-Titration, die zur Optimierung von Immunoassays verwendet wird. Ein bekannter Antikörper gegen das FLAG-Peptid, Klon M2, wurde als Modellsystem verwendet, und die Ergebnisse wurden mit anderen Methoden verglichen. Dieser Ansatz kann überall dort angewendet werden, wo ein kompetitiver Assay verfügbar ist oder entwickelt werden kann. Die Bestimmung einer Affinitätskonstante sollte zu den entscheidenden Parametern bei der Qualitätskontrolle von Antikörperprodukten und -assays gehören und in Arbeiten, die immunchemische Protokolle verwenden, obligatorisch sein.
KW - ELISA
KW - Competitive immunoassay
KW - IC50
KW - Test midpoint
KW - Point of inflection
KW - Equilibrium constant
KW - Dissociation constant
KW - Binding strength
KW - Antibody antigen complex
KW - Bio-interaction
KW - SPR
KW - Surface-plasmon resonance
KW - FLAG peptide
KW - Clone M2
KW - Antibody quality
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-605607
DO - https://doi.org/10.3390/mps7030049
SN - 2409-9279
VL - 7
IS - 3
SP - 1
EP - 11
PB - MDPI
CY - Basel
AN - OPUS4-60560
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Béalu, Zoé
A1 - Walther, Johanna
A1 - Abusafia, Attaallah
A1 - Altmann, Korinna
A1 - Meurer, Maren
A1 - Gretzschel, Oliver
A1 - Schäfer, Michael
A1 - Steinmetz, Heidrun
T1 - Removal of Organic Micropollutants and Microplastics via Ozonation Followed by Granular Activated Carbon Filtration
N2 - Discharge from Wastewater Treatment Plants (WWTPs) can result in the emission of organic micropollutants (OMPs) and microplastics (MPs) into the aquatic environment. To prevent this harmful release, a pilot plant consisting of an ozonation followed by a granular activated carbon (GAC) filter was operated at a WWTP in Germany, and its side-effects on the concentrations of nitrogen (N) and phosphorous (P) compounds were measured. Over 80% of OMPs and transformation products were removed during the operating time (around 6000 bed volumes) no matter the ozone dose (from around 0.1 to 0.5 mgO3/mgDOC), except for Diatrizoic acid, whose breakthrough appeared at 3500 BV. Formation of the oxidation by-product, NDMA, increased with higher ozone doses, but the concentration remained below 100 ng/L. Bromate was formed at a higher ozone dose (0.4 mgO3/mgDOC) but at a low concentration—below 10 µg/L. The MP particles detected in the inflow (PE, SBR, PP, and PS) were effectively eliminated to a high degree, with a removal rate of at least 92%. Carbon parameters (COD, DOC, and SAC254) were removed further by the pilot plant, but to different extents. As expected, nitrate was formed during ozonation, while nitrite’s concentration decreased. Further, nitrite decreased and nitrate increased within the GAC filter, while ammonium was eliminated by at least 90%. Total P concentration decreased after the pilot, but the concentration of PO4-P increased.
KW - Microplastics
KW - TED-GC/MS
KW - Granular Activated Carbon Filtration
KW - Removal of Organic Micropollutants
KW - Wastewater treatment plant
PY - 2024
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615209
DO - https://doi.org/10.3390/environments11110241
VL - 11
IS - 11
SP - 1
EP - 38
PB - MDPI AG
AN - OPUS4-61520
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Fadda, Marta
A1 - Sacco, Alessio
A1 - Altmann, Korinna
A1 - Ciornii, Dmitri
A1 - Milczewski, Frank
A1 - Bañares, Miguel A.
A1 - Portela, Raquel
A1 - Giovannozzi, Andrea Mario
A1 - Rossi, Andrea Mario
T1 - Tracking nanoplastics in drinking water: a new frontier with the combination of dielectrophoresis and Raman spectroscopy
N2 - Detection of micro- (MPs) and nanoplastics (NPs) in food and environmental matrices has been gaining relevance due to their potential toxicological effects on human health. While MPs have been detected in a wide range of complex matrices, suitable methods for the characterization and chemical identification of NPs are still lacking, primarily due to significant methodological challenges associated with their nano-specific physiochemical properties, including size distribution (1 nm – 1 µm), dynamic surface chemical changes, and carbon-based composition, which complicate their detection compared to engineered nanomaterials. To overcome the traditional limitations of spectroscopic techniques in terms of spatial resolution and sensitivity at the sub-micrometer level, a novel label-free methodology is presented for specifically identifying the chemical composition of NPs directly in suspension by combining Raman spectroscopy with dielectrophoresis (DEP). Using a custom-built device, small volumes of NPs are injected into a dielectrophoretic cell and locally trapped by DEP forces to fill the Raman confocal volume, facilitating their detection and identification, and providing high signal-to-noise ratio Raman spectra for more reliable analysis. This approach was successfully applied to both Milli-Q water and a commercial brand of drinking water, enabling the rapid identification of various types of NPs with different sizes and polymer compositions at concentrations as low as 20 µg/mL. These included certified reference polystyrene beads ranging from 800 to 60 nm in diameter, as well as polydisperse NPs, more representative of real samples in terms of size distribution and polymer type, such as polyethylene (450 nm), polypropylene (180 nm), and polyethylene terephthalate (100 nm). Moreover, the chemical fingerprint of each NPs was thoroughly investigated and compared with the corresponding bulk polymers, highlighting possible changes in the Raman bands due to surface oxidation or nanometer-scale effect. Therefore, this innovative method can be considered a valuable approach for addressing gaps in the detection and identification of NPs, as well as for monitoring their dynamic phisiochemical changes in real matrices.
KW - Nanoplastics
KW - Water contaminants
KW - Raman microspectroscopy
KW - Dielectrophoresis
PY - 2025
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-633658
DO - https://doi.org/10.1186/s43591-025-00131-y
SN - 2662-4966
VL - 5
IS - 1
SP - 1
EP - 11
PB - Springer Science and Business Media LLC
AN - OPUS4-63365
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Ciornii, Dmitri
A1 - Hodoroaba, Vasile-Dan
A1 - Wachtendorf, Volker
A1 - Fengler, Petra
A1 - Altmann, Korinna
T1 - Interlaboratory Comparison Reveals State of the Art in Microplastic Detection and Quantification Methods
N2 - In this study, we investigate the current accuracy of widely used microplastic (MP) detection methods through an interlaboratory comparison (ILC) involving ISO-approved techniques. The ILC was organized under the prestandardization platform of VAMAS (Versailles Project on Advanced Materials and Standards) and gathered a large number (84) of analytical laboratories across the globe. The aim of this ILC was (i) to test and to compare two thermo-analytical and three spectroscopical methods with respect to their suitability to identify and quantify microplastics in a water-soluble matrix and (ii) to test the suitability of the microplastic test materials to be used in ILCs. Two reference materials (RMs), polyethylene terephthalate (PET) and polyethylene (PE) as powders with rough size ranges between 10 and 200 μm, were used to press tablets for the ILC. The following parameters had to be assessed: polymer identity, mass fraction, particle number concentration, and particle size distribution. The reproducibility, SR, in thermo-analytical experiments ranged from 62%−117% (for PE) and 45.9%−62% (for PET). In spectroscopical experiments, the SR varied between 121% and 129% (for PE) and 64% and 70% (for PET). Tablet dissolution turned out to be a very challenging step and should be optimized. Based on the knowledge gained, development of guidance for improved tablet filtration is in progress. Further, in this study, we discuss the main sources of uncertainties that need to be considered and minimized for preparation of standardized protocols for future measurements with higher accuracy.
KW - Microplastics
KW - Interlaboratory comparison
KW - PlasticsFatE
KW - PET
KW - PE
KW - Reference materials
KW - VAMAS
KW - Thermo-analytical methods
KW - Spectroscopical methods
PY - 2025
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-630462
DO - https://doi.org/10.1021/acs.analchem.4c05403
SN - 1520-6882
VL - 97
SP - 8719
EP - 8728
PB - ACS Publications
AN - OPUS4-63046
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Bartczak, Dorota
A1 - Sikora, Aneta
A1 - Goenaga-Infante, Heidi
A1 - Altmann, Korinna
A1 - Drexel, Roland
A1 - Meier, Florian
A1 - Alasonati, Enrica
A1 - Lelong, Marc
A1 - Cado, Florence
A1 - Chivas-Joly, Carine
A1 - Fadda, Marta
A1 - Sacco, Alessio
A1 - Rossi, Andrea Mario
A1 - Pröfrock, Daniel
A1 - Wippermann, Dominik
A1 - Barbero, Francesco
A1 - Fenoglio, Ivana
A1 - Booth, Andy M.
A1 - Sørensen, Lisbet
A1 - Igartua, Amaia
A1 - Wouters, Charlotte
A1 - Mast, Jan
A1 - Barbaresi, Marta
A1 - Rossi, Francesca
A1 - Piergiovanni, Maurizio
A1 - Mattarozzi, Monica
A1 - Careri, Maria
A1 - Caebergs, Thierry
A1 - Piette, Anne-Sophie
A1 - Parot, Jeremie
A1 - Giovannozzi, Andrea Mario
T1 - Multiparameter characterisation of a nano-polypropylene representative test material with fractionation, light scattering, high-resolution microscopy, spectroscopy, and spectrometry methods
N2 - Reference and quality control materials with comparable physicochemical properties to nanoplastic contaminants present in environmental and food nanoplastics are currently lacking. Here we report a nanoplastic polypropylene material prepared using a top-down approach involving mechanical fragmentation of larger plastics. The material was found to be homogeneous and stable in suspension and has been characterised for average particle size, size distribution range, particle number concentration, polypropylene mass fraction and inorganic impurity Content using a wide range of analytical methods, including AF4, cFFF, PTA, (MA)DLS, MALS, SEM, AFM, TEM, STEM, EDS,Raman, ICP-MS and pyGC-MS. The material was found to have a broad size distribution, ranging from 50 nm to over 200 nm, with the average particle size value dependent on the technique used to determine it. Particle number concentration ranged from 1.7–2.4 × 1010 g−1 , according to PTA. Spectroscopy techniques confirmed that the material was polypropylene, with evidence of aging due to an increased level of oxidation. The measured mass fraction was found to depend on the marker used and ranged between 3 and 5 μg g−1 . Inorganic impurities such as Si, Al, Mg, K, Na, S, Fe, Cl and Ca were also identified at ng g−1 levels. Comparability and complementarity across the measurement methods and techniques is also discussed.
KW - Polypropylene
KW - Nanoplastics
KW - Analytics
KW - Reference material
KW - Scattering methods
PY - 2026
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654680
DO - https://doi.org/10.1039/D5EN00917K
SN - 2051-8153
SP - 1
EP - 15
PB - Royal Society of Chemistry (RSC)
AN - OPUS4-65468
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Kittner, Maria
A1 - Coesfeld, Bianca
A1 - Schlau, Sven
A1 - Werischak, Thomas
A1 - Altmann, Korinna
A1 - Kalbe, Ute
T1 - Simultaneous sampling for microplastics and environmental contaminants from artificial turf: development of a new integrated microplastics eluate lysimeter
N2 - To get a better understanding of potentially harmful contaminant emissions from soils or materials into the environment, politics demand practical and holistic sampling concepts for environmental samples such as leachates containing polycyclic aromatic hydrocarbons (PAH) or heavy metals, and hazardous particulate matter like microplastics (MP). Of particular concern are MP emissions from artificial turf sports pitches. So far, there has been only very limited data on MP mass emissions from artificial turf potentially posing a risk to the groundwater and no sampling device that allowed simultaneous sampling for dissolved and particulate contaminants. In this study, a novel integrative microplastics eluate lysimeter was developed to determine contaminant emissions from three artificial turf systems at different ageing states (fabric-new, artificially aged, real-time aged). For the accelerated ageing, all environmental simulation parameters were based on Central German conditions and simulated outdoor stress during the turf service lifespan of 15 years. MP masses from eluates were analysed using thermal extraction desorption-gas chromatography/mass spectrometry, PAH concentrations using gas chromatography/mass spectrometry and heavy metals using inductively coupled plasma-optical emission spectroscopy. Results showed that no PAH or heavy metal concentrations from the seepage water were above German legal limits for alternative granular construction materials considering soil and groundwater protection. Furthermore, it was found that only minimal MP emissions were released from new turf systems into the seepage water (< 1 mg/m2). Ageing of the artificial turf increased MP formation, especially from rubber infill and grass fibres, which are then carried into the seepage water. The highest total MP emissions over a simulated turf lifespan of 15 years were detected in two real-time aged turf systems ranging from 136.4–252.5 mg/m2. Considerably less total MP emissions were detected in accelerated aged artificial turf systems, one of which contained a synthetic rubber infill (5.4–8.0 mg/m2) and one without rubber infill (0.2–5.3 mg/m2). In summary, it was demonstrated that the newly developed MEL generated reliable and reproducible data and has thus proven itself as an integrated, straightforward and automated sampling device for simultaneous monitoring of particulate and dissolved pollutant emissions from simple soil matrices.
KW - Lysimeter
KW - Microplastics
KW - Artificial turf
KW - Thermal extraction desorption-gas chromatography/mass spectrometry
KW - TED-GC/MS
KW - Polycyclic aromatic hydrocarbons
KW - PAH
KW - Heavy metals
KW - Soil samples
PY - 2025
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-645301
DO - https://doi.org/10.1186/s12302-025-01235-1
SN - 2190-4715
VL - 37
IS - 1
SP - 1
EP - 15
PB - Springer Open
AN - OPUS4-64530
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Herzel, Hannes
A1 - Grevel, K.-D.
A1 - Emmerling, Franziska
A1 - Dachs, E.
A1 - Benisek, A.
A1 - Adam, Christian
A1 - Majzlan, J.
T1 - Thermodynamic properties of calcium alkali phosphates Ca(Na,K)PO4
N2 - Calcium alkali phosphates Ca(Na,K)PO4 are main constituents of bioceramics and thermochemically produced phosphorus fertilizers because of their bioavailability. Sparse thermodynamic data are available for the endmembers CaNaPO4 and CaKPO4. In this work, the missing data were determined for the low-temperature phase modifications of the endmembers CaNaPO4 and CaKPO4 and three intermediate Ca(Na,K)PO4 compositions. Standard enthalpy of formation ranges from - 2018.3 ± 2.2 kJ mol-1 to - 2030.5 ± 2.1 kJ mol-1 and standard entropy from 137.2 ± 1.0 J mol-1 K-1 to 148.6 ± 1.0 J mol-1 K-1 from sodium endmember b-CaNaPO4 to potassium endmember b0-CaKPO4.
Thermodynamic functions are calculated up to 1400 K for endmembers and the sodium-rich intermediate phase b-Ca(Na0.93K0.07)PO4. Functions above 640 K are extrapolated because of the phase transition from low- to high-temperature phase. Impurities in the synthesized intermediate phases c-Ca(Na0.4K0.6)PO4 and c-Ca Na0.35K0.65)PO4 and one additional phase transition around 500 K impeded the determination of high-temperature thermodynamic functions. In general, data for phase transition temperatures agree with the previously reported phase diagrams.
KW - Formation enthalpy
KW - Heat capacity
KW - Phase transformation
KW - Bioceramics
KW - Phosphorus fertilizer
KW - Entropy
PY - 2020
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-507640
DO - https://doi.org/10.1007/s10853-020-04615-5
VL - 55
SP - 8477
EP - 8490
PB - Springer
AN - OPUS4-50764
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - GEN
A1 - Steglich, P.
A1 - Rabus, D. G.
A1 - Sada, C.
A1 - Paul, Martin
A1 - Weller, Michael G.
A1 - Mai, C.
A1 - Mai, A.
T1 - Silicon Photonic Micro-Ring Resonators for Chemical and Biological Sensing: A Tutorial
N2 - Silicon photonic micro-ring resonators (MRR) developed on the silicon-on-insulator (SOI) platform, owing to their high sensitivity and small footprint, show great potential for many chemical and biological sensing applications such as label-free detection in environmental monitoring, biomedical engineering, and food analysis. In this tutorial, we provide the theoretical background and give design guidelines for SOI-based MRR as well as examples of surface functionalization procedures for label-free detection of molecules.
After introducing the advantages and perspectives of MRR, fundamentals of MRR are described in detail, followed by an introduction to the fabrication methods, which are based on a complementary metal-oxide semiconductor (CMOS) technology. Optimization of MRR for chemical and biological sensing is provided, with special emphasis on the optimization of waveguide geometry. At this point, the difference between chemical bulk sensing and label-free surface sensing is explained, and definitions like waveguide sensitivity, ring sensitivity, overall sensitivity as well as the limit of detection (LoD) of MRR are introduced. Further, we show and explain chemical bulk sensing of sodium chloride (NaCl) in water and provide a recipe for label-free surface sensing.
KW - Lab on a chip
KW - Biosensor
KW - Cmos
KW - Silanization
KW - Surface derivatization
KW - Evanescent wave
PY - 2021
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529360
DO - https://doi.org/10.36227/techrxiv.14909901.v1
SP - 1
EP - 18
PB - IEEE
CY - Piscataway Township
AN - OPUS4-52936
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Paul, Martin
A1 - Tannenberg, Robert
A1 - Tscheuschner, Georg
A1 - Ponader, Marco
A1 - Weller, Michael G.
T1 - Cocaine detection by a laser-induced immunofluorometric biosensor
N2 - The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue for public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 7 ppt (23 pM) of cocaine with a response time of 90 s and a total assay time below 3 min. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement.
KW - Online detection
KW - Security
KW - Monoclonal antibody
KW - Microfluidic mixing
KW - Microfluidics
KW - Lab-on-a-chip
KW - Monolithic column
KW - Affinity chromatography
KW - Laser-induced fluorescence
KW - LIF
KW - ELISA
KW - Wipe test
KW - Low-cost
PY - 2021
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-534487
DO - https://doi.org/10.3390/bios11090313
VL - 11
IS - 9
SP - 1
EP - 15
PB - MDPI
CY - Basel
AN - OPUS4-53448
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Möckel, J.
A1 - Brangsch, J.
A1 - Reimann, C.
A1 - Kaufmann, Jan Ole
A1 - Sack, I.
A1 - Mangarova, D. B.
A1 - Kader, A.
A1 - Taupitz, M.
A1 - Adams, L. C.
A1 - Keller, S.
A1 - Ludwig, A.
A1 - Hamm, B.
A1 - Botnar, R. M.
A1 - Makowski, M. R.
T1 - Assessment of Albumin ECM Accumulation and Inflammation as Novel In Vivo Diagnostic Targets for Multi-Target MR Imaging
N2 - Atherosclerosis is a progressive inflammatory vascular disease characterized by endothelial dysfunction and plaque burden. Extracellular matrix (ECM)-associated plasma proteins play an important role in disease development. Our magnetic resonance imaging (MRI) study investigates the feasibility of using two different molecular MRI probes for the simultaneous assessment of ECM-associated intraplaque albumin deposits caused by endothelial damage and progressive inflammation in atherosclerosis. Male apolipoprotein E-deficient (ApoE-/-)-mice were fed a high-fat diet (HFD) for 2 or 4 months. Another ApoE-/--group was treated with pravastatin and received a HFD for 4 months. T1- and T2*-weighted MRI was performed before and after albumin-specific MRI probe (gadofosveset) administration and a macrophage-specific contrast agent (ferumoxytol). Thereafter, laser ablation inductively coupled plasma mass spectrometry and histology were performed. With advancing atherosclerosis, albumin-based MRI signal enhancement and ferumoxytol-induced signal loss areas in T2*-weighted MRI increased. Significant correlations between contrast-to-noise-ratio (CNR) post-gadofosveset and albumin stain (R2 = 0.78, p < 0.05), and signal loss areas in T2*-weighted MRI with Perls’ Prussian blue stain (R2 = 0.83, p < 0.05) were observed. No interference of ferumoxytol with gadofosveset enhancement was detectable. Pravastatin led to decreased inflammation and intraplaque albumin. Multi-target MRI combining ferumoxytol and gadofosveset is a promising method to improve diagnosis and treatment monitoring in atherosclerosis.
KW - Magnetic resonance imaging
KW - MRI
KW - Imaging
KW - Human serum albumin
KW - Extracellular matrix
KW - Macrophages
KW - Contrast agent
KW - Atherosclerotic plaques
KW - Gadofosveset
KW - Aneurysm
PY - 2021
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-536725
DO - https://doi.org/10.3390/biology10100964
VL - 10
IS - 10
SP - 1
EP - 16
PB - MDPI
CY - Basel
AN - OPUS4-53672
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Backes, A. T.
A1 - Reinmuth-Selzle, K.
A1 - Leifke, A. L.
A1 - Ziegler, K.
A1 - Krevert, C. S.
A1 - Tscheuschner, Georg
A1 - Lucas, K.
A1 - Weller, Michael G.
A1 - Berkemeier, T.
A1 - Pöschl, U.
A1 - Fröhlich-Nowoisky, J.
T1 - Oligomerization and Nitration of the Grass Pollen Allergen Phl p 5 by Ozone, Nitrogen Dioxide, and Peroxynitrite: Reaction Products, Kinetics, and Health Effects
N2 - The allergenic and inflammatory potential of proteins can be enhanced by chemical modification upon exposure to atmospheric or physiological oxidants. The molecular mechanisms and kinetics of such modifications, however, have not yet been fully resolved. We investigated the oligomerization and nitration of the grass pollen allergen Phl p 5 by ozone (O3), nitrogen dioxide (NO2), and peroxynitrite (ONOO–). Within several hours of exposure to atmospherically relevant concentration levels of O3 and NO2, up to 50% of Phl p 5 were converted into protein oligomers, likely by formation of dityrosine cross-links. Assuming that tyrosine residues are the preferential site of nitration, up to 10% of the 12 tyrosine residues per protein monomer were nitrated. For the reaction with peroxynitrite, the largest oligomer mass fractions (up to 50%) were found for equimolar concentrations of peroxynitrite over tyrosine residues. With excess peroxynitrite, the nitration degrees increased up to 40% whereas the oligomer mass fractions decreased to 20%. Our results suggest that protein oligomerization and nitration are competing processes, which is consistent with a two-step mechanism involving a reactive oxygen intermediate (ROI), as observed for other proteins. The modified proteins can promote pro-inflammatory cellular signaling that may contribute to chronic inflammation and allergies in response to air pollution.
KW - Protein
KW - Nitrotyrosine
KW - Dityrosine
KW - Allergy
KW - Hay fever
KW - Diesel exhaust
KW - Combustion
KW - Exhaust
PY - 2021
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529729
DO - https://doi.org/10.3390/ijms22147616
VL - 22
IS - 14
PB - MDPI
CY - Basel
AN - OPUS4-52972
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Adams, L. C.
A1 - Brangsch, J.
A1 - Reimann, C.
A1 - Kaufmann, Jan Ole
A1 - Buchholz, R.
A1 - Karst, U.
A1 - Botnar, R. M.
A1 - Hamm, B.
A1 - Makowski, M. R.
T1 - Simultaneous molecular MRI of extracellular matrix collagen and inflammatory activity to predict abdominal aortic aneurysm rupture
N2 - Abdominal aortic aneurysm (AAA) is a life-threatening vascular disease with an up to 80% mortality in case of rupture. Current biomarkers fail to account for size-independent risk of rupture. By combining the information of different molecular probes, multi-target molecular MRI holds the potential to enable individual characterization of AAA. In this experimental study, we aimed to examine the feasibility of simultaneous imaging of extracellular collagen and inflammation for size-independent prediction of risk of rupture in murine AAA. The study design consisted of: (1) A outcome-based longitudinal study with imaging performed once after one week with follow-up and death as the end-point for assessment of rupture risk. (2) A week-by-week study for the characterization of AAA development with imaging after 1, 2, 3 and 4 weeks. For both studies, the animals were administered a type 1 collagen-targeted gadolinium-based probe (surrogate marker for extracellular matrix (ECM) remodeling) and an iron oxide-based probe (surrogate marker for inflammatory activity), in one imaging session. In vivo measurements of collagen and iron oxide probes showed a significant correlation with ex vivo histology (p < 0.001) and also corresponded well to inductively-coupled plasma-mass spectrometry and laser-ablation inductively-coupled plasma mass spectrometry. Combined evaluation of collagen-related ECM remodeling and inflammatory activity was the most accurate predictor for AAA rupture (sensitivity 80%, specificity 100%, area under the curve 0.85), being superior to information from the individual probes alone. Our study supports the feasibility of a simultaneous assessment of collagen-related extracellular matrix remodeling and inflammatory activity in a murine model of AAA.
KW - Atherosclerosis
KW - Specific probe
KW - Magnetic resonance imaging
KW - Gadolinium
KW - Iron oxide
KW - Ferumoxytol
KW - Inductively‑coupled mass spectrometry
KW - ICP-MS
KW - LA-ICP-MS
KW - Laser ablation
PY - 2020
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-525864
UR - https://www.nature.com/articles/s41598-020-71817-x
DO - https://doi.org/10.1038/s41598-020-71817-x
VL - 10
IS - 1
SP - 15206
PB - Springer Nature Limited
CY - London, New York, Berlin, Shanghai and Tokyo
AN - OPUS4-52586
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -
TY - JOUR
A1 - Ponader, Marco
A1 - Röder, Bettina
A1 - Paul, Martin
A1 - Weller, Michael G.
T1 - Sintered glass monoliths as supports for affinity columns
N2 - A novel stationary phase for affinity separations is presented. This material is based on sintered borosilicate glass readily available as semi-finished filter plates with defined porosity and surface area. The material shows fast binding kinetics and excellent long-term stability under real application conditions due to lacking macropores and high mechanical rigidity. The glass surface can be easily modified with standard organosilane chemistry to immobilize selective binders or other molecules used for biointeraction. In this paper, the manufacturing of the columns and their respective column holders by 3D printing is shown in detail. The model system protein A/IgG was chosen as an example to examine the properties of such monolithic columns under realistic application conditions. Several specifications, such as (dynamic) IgG capacity, pressure stability, long-term performance, productivity, non-specific binding, and peak shape, are presented. It could be shown that due to the very high separation speed, 250 mg antibody per hour and column can be collected, which surpasses the productivity of most standard columns of the same size. The total IgG capacity of the shown columns is around 4 mg (5.5 mg/mL), which is sufficient for most tasks in research laboratories. The cycle time of an IgG separation can be less than 1 min. Due to the glass material’s excellent pressure resistance, these columns are compatible with standard HPLC systems. This is usually not the case with standard affinity columns, limited to manual use or application in low-pressure systems. The use of a standard HPLC system also improves the ability for automation, which enables the purification of hundreds of cell supernatants in one day. The sharp peak shape of the elution leads to an enrichment effect, which might increase the concentration of IgG by a factor of 3. The final concentration of IgG can be around 7.5 mg/mL without the need for an additional nano-filtration step. The purity of the IgG was > 95% in one step and nearly 99% with a second polishing run.
KW - Affinity Chromatography
KW - Affinity Extraction
KW - Affinity Separation
KW - Protein Purification
KW - Down Stream Processing
KW - Antibody Purification
KW - Diagnostic Antibodies
KW - Therapeutic Antibodies
KW - Automated Purification
KW - HPLC
KW - FPLC
KW - IgG determination
KW - Concentration step
KW - Monoclonal Antibodies
KW - Polyclonal Antibodies
KW - Human Plasma
KW - Glass Support
KW - Borosilicate Glass
KW - Monolith
KW - Sintered Material
KW - Additive Manufacturing
KW - Column holder
KW - Construction
KW - Open Science
KW - Citizen Science
KW - Protein A
KW - Regeneration
KW - High-Speed Separations
KW - Robustness
PY - 2021
UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527581
DO - https://doi.org/10.3390/separations8050056
SN - 2297-8739
N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M.
VL - 8
IS - 5
SP - 1
EP - 16
PB - MDPI
CY - Basel
AN - OPUS4-52758
LA - eng
AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany
ER -