TY - JOUR A1 - Poli, Marco A1 - Grätz, Rainer A1 - Schröder, Volkmar T1 - An experimental study on safety-relevant parameters of turbulent gas explosion venting at elevated initial pressure N2 - The effects of a gas explosion in enclosures like vessels can be limited e.g. by gas explosion venting systems. The major design step of this constructive explosion protection method is to determine the required vent area, which depends significantly on whether turbulent combustion exists. However, current standards like NFPA 68 or EN 14994 are applicable only to limited boundary conditions and as far as possible only to laminar flame propagation. Difficulties arise in the assessment or predictability of gas explosion hazard when turbulence occurs. In this research especially venting at elevated initial pressure has been shown to accelerated flame propagations and therefore, to a considerably higher reduced pressure. Therefore, it is essential to provide a broader data base of turbulent combustion and explosion behavior to verify the existing rules or to determine their safety-relevant parameters. For a better safety assessment or design of protective systems the turbulent combustion and accelerated gas explosion behaviour of quiescent methane and hydrogen in air were investigated at initial pressures up to 8 bar using vessels up to 100 litres. In particular a systematic study was performed to investigate the influence of turbulence on the overpressure development during accelerated gas explosion. Moreover, the present study consider the position of the spark igniters, the burning velocity and the maximum pressure rise for different concentration of fuel as well as the size of orifice and/or vent area. A choice of experimental tests showed under the investigated conditions that not only turbulence inducing obstacles but also over sized vent areas could lead to an increased pressure development and therefore to an inacceptable safety state. T2 - 20th International Congress of Chemical and Process Engineering CHISA 2012 CY - Prague, Czech Republic DA - 25.08.2012 KW - Gas explosion venting KW - Turbulent combustion KW - Obstacles PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-264288 DO - https://doi.org/10.1016/j.proeng.2012.07.398 SN - 1877-7058 VL - 42 SP - 90 EP - 99 PB - Elsevier CY - Amsterdam AN - OPUS4-26428 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Meira, Maria Fernanda Cavalcante A1 - Fernandes, Gabriela Leal Peres A1 - de Camargo, Andréa Simone Stucchi A1 - Ravaro, Leandro Piaggi A1 - Arai, Marylyn Setsuko A1 - Navarro, Maria Fidela de Lima A1 - Brighenti, Fernanda Lourenção A1 - Oliveira, Analú Barros de A1 - Danelon, Marcelle ED - Stucchi de Camargo, Andrea T1 - Modification of restorative glass ionomer cement with zinc oxide nanoparticles and calcium glycerophosphate microparticles: in vitro assessment of mechanical properties and antimicrobial activity N2 - Abstract The incorporation of bioactive agents into resin-modified glass ionomer cement (RMGIC) is a promising strategy to improve its mechanical strength and biofilm control, especially for patients with active dental caries. Objective This study aimed to evaluate the effects of incorporating ZnONPs and CaGP into RMGIC on its mechanical and microbiological properties. Design Six groups were tested: 1) RMGIC (without CaGP/ZnONPs); 2) RMGIC-1.0%ZnONPs; 3) RMGIC-2.0%ZnONPs; 4) RMGIC-3.0%CaGP; 5) RMGIC-3.0%CaGP-1.0%ZnONPs; and 6) RMGIC-3.0%CaGP-2.0%ZnONPs. The compressive strength (CS), diametral tensile strength (DTS), and surface hardness (SH) were evaluated after 24 hours and 7 days. Antimicrobial and antibiofilm activity were evaluated using agar diffusion and biofilm metabolic activity (XTT) assays. Results After 24 hours, all the groups showed similar DTS values (p0.05), except for RMGIC-3.0%CaGP-1.0%ZnONPs, which showed the highest DTS value (p<0.05). Comparing 24 hours and 7 days, the DTS values of RMGIC-3.0%CaGP-2.0%ZnONPs, RMGIC-3.0%CaGP, and RMGIC-3.0%CaGP-2.0%ZnONPs were similar (p=0.360). After 24 hours, the RMGIC group showed the CS highest value, followed by RMGIC-2.0%ZnONPs (p < 0.05). After 7 days, the RMGIC-3.0%CaGP-1.0%ZnONPs group exhibited the highest CS value, approximately 15% higher than RMGIC (p<0.05). The RMGIC-1.0%ZnONPs group exhibited significantly higher SH at 24 hours (p=0.621). At 7 days, the highest SH value was observed for the RMGIC-3.0%CaGP-1.0%ZnONPs group (p<0.05). Regarding antimicrobial and antibiofilm activity, including results from biofilm metabolism assays, the RMGIC-3.0%CaGP-1.0%ZnONPs group demonstrated the most effective antimicrobial and inhibitory effects (p<0.05). Conclusion This study demonstrated that adding ZnONPs and CaGP to RMGIC enhanced its mechanical and antimicrobial and antibiofilm properties, suggesting enhanced mechanical performance and improved protection against cariogenic biofilms—critical factors for successful restorative treatments. Therefore, the addition of ZnONPs and CaGP is a promising strategy to develop advanced restorative materials that improve clinical outcomes, especially for patients with active dental caries. KW - Resin-modified glass ionomer cement KW - Phosphate KW - Zinc oxide nanoparticles KW - Biofilm KW - Mechanical properties PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652799 DO - https://doi.org/10.1590/1678-7757-2025-0356 SN - 1678-7765 VL - 33 SP - 1 EP - 14 PB - FapUNIFESP (SciELO) AN - OPUS4-65279 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Arai, Marylyn S. A1 - Brambilla, Gabriel V. A1 - Corrêa, Bruna Carolina A1 - Merízio, Leonnam G. A1 - Inada, Natalia M. A1 - de Camargo, Andrea S. S. T1 - A Dual-Mode “Turn-On” Ratiometric Luminescent Sensor Based on Upconverting Nanoparticles for Detection and Differentiation of Gram-Positive and Gram-Negative Bacteria N2 - Infectious bacterial diseases, intensified by antibiotic resistance, cause millions of deaths annually and pose risks beyond human health, including water and food contamination. Current diagnostics are often slow, require complex equipment, and lack specificity, highlighting the need for rapid and reliable detection methods. To address this, we developed a luminescent sensor based on NaYF4 upconverting nanoparticles (UCNPs) doped with Er3+ or Tm3+, coated with COOH-PEG4-COOH, and functionalized with vancomycin (Van) or polymyxin-B (Poly) to selectively target Gram-positive and Gram-negative bacteria, respectively. Gold nanoparticles (AuNPs) served as quenchers, enabling a ratiometric “turn-on” mechanism: upon bacterial binding, the UCNP emission, initially quenched by AuNPs, was partially restored. This allowed Differentiation through changes in the green/red (G/R) ratio for Er-UCNP@PEG4-Van and the blue/red (B/R) ratio for Tm-UCNP@PEG4-Poly. The sensor distinguished between Gram-positive and Gram-negative bacteria over a wide concentration range (0.05 to 5 × 105 CFU/mL) and showed high correlation with actual bacterial counts (r = 0.99 for S. aureus, r = 0.91 for E. coli). This platform is a potential fast, selective, and reliable tool for bacterial detection in clinical and environmental settings. KW - Lminescent sensor KW - Upconverting nanoparticles KW - Gram-positive and Gram-negative bacteria KW - Ratiometric luminescent sensors PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652785 DO - https://doi.org/10.1021/acsomega.5c07006 SN - 2470-1343 VL - 10 IS - 39 SP - 46040 EP - 46050 PB - American Chemical Society (ACS) AN - OPUS4-65278 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Afantitis, A. A1 - Melagraki, G. A1 - Isigonis, P. A1 - Tsoumanis, A. A1 - Varsou, D. D. A1 - Valsami-Jones, E. A1 - Papadiamantis, A. A1 - Ellis, L.-J. A. A1 - Sarimveis, H. A1 - Doganis, P. A1 - Karatzas, P. A1 - Tsiros, P. A1 - Liampa, I. A1 - Lobaskin, V. A1 - Greco, D. A1 - Serra, A. A1 - Kinaret, P. A. S. A1 - Saarimäki, L. A. A1 - Grafström, R. A1 - Kohonen, P. A1 - Nymark, P. A1 - Willighagen, E. A1 - Puzyn, T. A1 - Rybinska-Fryca, A. A1 - Lyubartsev, A. A1 - Jensen, K. A. A1 - Brandenburg, J. G. A1 - Lofts, S. A1 - Svendsen, C. A1 - Harrison, S. A1 - Maier, D. A1 - Tamm, K. A1 - Jänes, J. A1 - Sikk, L. A1 - Dusinska, M. A1 - Longhin, E. A1 - Rundén-Pran, E. A1 - Mariussen, E. A1 - El Yamani, N. A1 - Unger, Wolfgang A1 - Radnik, Jörg A1 - Tropsha, A. A1 - Cohen, Y. A1 - Lesczynski, J. A1 - Hendren, C. O. A1 - Wiesner, M. A1 - Winkler, D. A1 - Suzuki, N. A1 - Yoon, T. H. A1 - Choi, J.-S. A1 - Sanabria, N. A1 - Gulumian, M. A1 - Lynch, I. T1 - NanoSolveIT Project: Driving nanoinformatics research to develop innovative and integrated tools for in silico nanosafety assessment N2 - Nanotechnology has enabled the discovery of a multitude of novel materials exhibiting unique physicochemical (PChem) properties compared to their bulk analogues. These properties have led to a rapidly increasing range of commercial applications; this, however, may come at a cost, if an association to long-term health and environmental risks is discovered or even just perceived. Many nanomaterials (NMs) have not yet had their potential adverse biological effects fully assessed, due to costs and time constraints associated with the experimental assessment, frequently involving animals. Here, the available NM libraries are analyzed for their suitability for integration with novel nanoinformatics approaches and for the development of NM specific Integrated Approaches to Testing and Assessment (IATA) for human and environmental risk assessment, all within the NanoSolveIT cloud-platform. These established and well-characterized NM libraries (e.g. NanoMILE, NanoSolutions, NANoREG, NanoFASE, caLIBRAte, NanoTEST and the Nanomaterial Registry (>2000 NMs)) contain physicochemical characterization data as well as data for several relevant biological endpoints, assessed in part using harmonized Organisation for Economic Co-operation and Development (OECD) methods and test guidelines. Integration of such extensive NM information sources with the latest nanoinformatics methods will allow NanoSolveIT to model the relationships between NM structure (morphology), properties and their adverse effects and to predict the effects of other NMs for which less data is available. The project specifically addresses the needs of regulatory agencies and industry to effectively and rapidly evaluate the exposure, NM hazard and risk from nanomaterials and nano-enabled products, enabling implementation of computational ‘safe-by-design’ approaches to facilitate NM commercialization. KW - Nanoinformatics KW - Hazard assessment KW - (Quantitative) Structure-Active Relationships KW - Safe-by-design KW - Predictive modelling PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-505952 DO - https://doi.org/10.1016/j.csbj.2020.02.023 VL - 18 SP - 583 EP - 602 PB - Elsevier B.V. AN - OPUS4-50595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Agostini, G. A1 - Radnik, Jörg T1 - Spectroscopy in Catalysis N2 - Knowledge-based catalyst development is always an interaction between preparation, analysis and catalytic testing. Only if these three factors fit together can success be expected. For the analytic side of this triangle, spectroscopic methods play a crucial role. Whereas with diffraction, scattering and microscopy, decisive insights into the structure and morphology of the catalysts can be obtained, spectroscopy produces new knowledge about the chemical nature of the catalyst, e.g., its bonding and valence states. KW - Spectroscopy KW - Catalysis KW - Operando KW - In situ PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-506507 DO - https://doi.org/10.3390/catal10040408 VL - 10 IS - 4 SP - 408 PB - MDPI CY - Basel AN - OPUS4-50650 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mohammadifar, E. A1 - Ahmadi, V. A1 - Gholami, M.F. A1 - Oehrl, A. A1 - Kolyvushko, O. A1 - Nie, C. A1 - Donskyi, Ievgen A1 - Herziger, S. A1 - Radnik, Jörg A1 - Ludwig, K. A1 - Böttcher, C. A1 - Rabe, J.P. A1 - Osterrieder, K. A1 - Azab, W. A1 - Haag, R. A1 - Adeli, M. T1 - Graphene-Assisted Synthesis of 2D Polyglycerols as Innovative Platforms for Multivalent Virus Interactions N2 - 2D nanomaterials have garnered widespread attention in biomedicine and bioengineering due to their unique physicochemical properties. However, poor functionality, low solubility, intrinsic toxicity, and nonspecific interactions at biointerfaces have hampered their application in vivo. Here, biocompatible polyglycerol units are crosslinked in two dimensions using a graphene-assisted strategy leading to highly functional and water-soluble polyglycerols nanosheets with 263 ± 53 nm and 2.7 ± 0.2 nm average lateral size and thickness, respectively. A single-layer hyperbranched polyglycerol containing azide functional groups is covalently conjugated to the surface of a functional graphene template through pH-sensitive linkers. Then, lateral crosslinking of polyglycerol units is carried out by loading tripropargylamine on the surface of graphene followed by lifting off this reagent for an on-face click reaction. Subsequently, the polyglycerol nanosheets are detached from the surface of graphene by slight acidification and centrifugation and is sulfated to mimic heparin sulfate proteoglycans. To highlight the impact of the two-dimensionality of the synthesized polyglycerol sulfate nanosheets at nanobiointerfaces, their efficiency with respect to herpes Simplex virus type 1 and severe acute respiratory syndrome corona virus 2 inhibition is compared to their 3D nanogel analogs. Four times stronger in virus Inhibition suggests that 2D polyglycerols are superior to their current 3D counterparts.2D nanomaterials have garnered widespread attention in biomedicine and bioengineering due to their unique physicochemical properties. However, poor functionality, low solubility, intrinsic toxicity, and nonspecific interactions at biointerfaces have hampered their application in vivo. Here, biocompatible polyglycerol units are crosslinked in two dimensions using a graphene-assisted strategy leading to highly functional and water-soluble polyglycerols nanosheets with 263 ± 53 nm and 2.7 ± 0.2 nm average lateral size and thickness, respectively. A single-layer hyperbranched polyglycerol containing azide functional groups is covalently conjugated to the surface of a functional graphene template through pH-sensitive linkers. Then, lateral crosslinking of polyglycerol units is carried out by loading tripropargylamine on the surface of graphene followed by lifting off this reagent for an on-face click reaction. Subsequently, the polyglycerol nanosheets are detached from the surface of graphene by slight acidification and centrifugation and is sulfated to mimic heparin sulfate proteoglycans. To highlight the impact of the two-dimensionality of the synthesized polyglycerol sulfate nanosheets at nanobiointerfaces, their efficiency with respect to herpes Simplex virus type 1 and severe acute respiratory syndrome corona virus 2 inhibition is compared to their 3D nanogel analogs. Four times stronger in virus Inhibition suggests that 2D polyglycerols are superior to their current 3D counterparts. KW - 2D Materials KW - Graphene template KW - Multivalency KW - Polyglycerol KW - Virus inhibition PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527726 DO - https://doi.org/10.1002/adfm.202009003 VL - 31 IS - 32 SP - 2009003 PB - Wiley VCH AN - OPUS4-52772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jungnickel, R. A1 - Mirabella, Francesca A1 - Stockmann, Jörg Manfred A1 - Radnik, Jörg A1 - Balasubramanian, K. T1 - Graphene‑on‑gold surface plasmon resonance sensors resilient to high‑temperature annealing N2 - Gold films coated with a graphene sheet are being widely used as sensors for the detection of label-free binding interactions using surface plasmon resonance (SPR). During the preparation of such sensors, it is often essential to subject the sensor chips to a high-temperature treatment in order to ensure a clean graphene surface. However, sensor chips used currently, which often use chromium as an adhesion promoter, cannot be subjected to temperatures above 250 °C, because under such conditions, chromium is found to reorganize and diffuse to the surface, where it is easily oxidized, impairing the quality of SPR spectra. Here we present an optimized preparation strategy involving a three-cycle tempering coupled with chromium (oxide) etching, which allows the graphene-coated SPR chips to be annealed up to 500 °C with little deterioration of the surface morphology. In addition, the treatment delivers a surface that shows a clear enhancement in spectral response together with a good refractive index sensitivity. We demonstrate the applicability of our sensors by studying the kinetics of avidin–biotin binding at different pH repeatedly on the same chip. The possibility to anneal can be exploited to recover the original surface after sensing trials, which allowed us to reuse the sensor for at least six cycles of biomolecule adsorption. KW - Surface plasmon resonance KW - Graphene KW - Sensing KW - Surface regeneration PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-564585 DO - https://doi.org/10.1007/s00216-022-04450-4 SN - 1618-2642 SP - 1 EP - 7 PB - Springer AN - OPUS4-56458 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nickl, Philip A1 - Hilal, T. A1 - Olal, D. A1 - Donskyi, Ievgen A1 - Radnik, Jörg A1 - Ludwig, K. A1 - Haag, R. T1 - A New Support Film for Cryo Electron Microscopy Protein Structure Analysis Based on Covalently Functionalized Graphene N2 - Protein adsorption at the air–water interface is a serious problem in cryogenic electron microscopy (cryoEM) as it restricts particle orientations in the vitrified ice-film and promotes protein denaturation. To address this issue, the preparation of a graphene-based modified support film for coverage of conventional holey carbon transmission electron microscopy (TEM) grids is presented. The chemical modification of graphene sheets enables the universal covalent anchoring of unmodified proteins via inherent surface-exposed lysine or cysteine residues in a one-step reaction. Langmuir–Blodgett (LB) trough approach is applied for deposition of functionalized graphene sheets onto commercially available holey carbon TEM grids. The application of the modified TEM grids in single particle analysis (SPA) shows high protein binding to the surface of the graphene-based support film. Suitability for high resolution structure determination is confirmed by SPA of apoferritin. Prevention of protein denaturation at the air–water interface and improvement of particle orientations is shown using human 20S proteasome, demonstrating the potential of the support film for structural biology. KW - Functionalized graphene KW - Transmission electron microsocpy KW - Protein structure PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-566443 DO - https://doi.org/10.1002/smll.202205932 SN - 1613-6810 SP - 2205932 PB - Wiley VCH AN - OPUS4-56644 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Castells-Gil, Javier A1 - Zhu, Jinjie A1 - Itskou, Ioanna A1 - Wolpert, Emma H. A1 - Hunter, Robert D. A1 - Tidey, Jeremiah P. A1 - Pedersen, Angus A1 - Solvay, Elisa A1 - Tyrrell, Helen A1 - Petit, Camille A1 - Barrio, Jesús T1 - Impact of N-heterocyclic amine modulators on the structure and thermal conversion of a zeolitic imidazole framework N2 - The zeolitic imidazole framework-8 (ZIF-8) is a crystalline porous material that has been widely employed as template to fabricate porous nitrogen-doped carbons with high microporosity via thermal treatment at high temperatures. The properties of the carbon scaffold are influenced by the pore structure and chemical composition of the parent ZIF. However, the narrow pore size distribution and microporous nature from ZIF-8 often results in low mesopore volume, which is crucial for applications such as energy storage and conversion. Here we show that insertion of N-heterocyclic amines can disrupt the structure of ZIF-8 and dramatically impact the chemical composition and pore structure of the nitrogen-doped carbon frameworks obtained after high-temperature pyrolysis. Melamine and 2,4,6-triaminopyrimidine were chosen to modify the ZIF-8 structure owing to their capability to both coordinate metal ions and establish supramolecular interactions. Employing a wide variety of physical characterization techniques we observed that melamine results in the formation of a mixed-phase material comprising ZIF-8, Zn(Ac)6(Mel)2 and crystallized melamine, while 2,4,6-triaminopyrimidine induces the formation of defects, altering the pore structure. Furthermore, the absence of heterocyclic amine in the ZIF-8 synthesis leads to a new crystalline phase, unreported to date. The thermal conversion of the modified ZIFs at 1000 °C leads to nitrogen-doped carbons bearing Zn moieties with increased surface area, mesopore volume and varying degree of defects compared to ZIF-8 derived carbon. This work therefore highlights both the versatility of heterocyclic amines to modify the structure of framework materials as well as their role in tuning pore structure in nitrogen-doped carbons, paving the way to targeted design of high-performance electrodes for energy storage and conversion. KW - Zeolitic imidazole framework KW - Heterocyclic amine KW - Triaminopyrimidine PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-639177 DO - https://doi.org/10.1039/D5TA04831A SN - 2050-7488 SP - 1 EP - 13 PB - Royal Society of Chemistry (RSC) AN - OPUS4-63917 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Braga, Daniel S. A1 - Pedersen, Angus A1 - Riyaz, Mohd A1 - Barrio, Jesús A1 - Bagger, Alexander A1 - Neckel, Itamar T. A1 - Mariano, Thiago M. A1 - Winkler, Manuel E. G. A1 - Stephens, Ifan E. L. A1 - Titirici, Maria‐Magdalena A1 - Nagao, Raphael T1 - In situ structural evolution and activity descriptor of atomically dispersed catalysts during nitrate electroreduction N2 - Single‐Atom Catalysts (SAC) have emerged as a promising class of materials for various catalytic applications, including the electrochemical nitrate reduction reaction (eNO3RR) and consequently ammonia production. While the efficiency and selectivity of these materials have been extensively highlighted for the eNO3RR, the in situ evolution to their structure and composition during electrocatalysis is largely unexplored and lacks catalyst design principles. To solve this, we investigated a series of high utilization metal‐nitrogen‐carbon (MNC) SACs (M = Cr, Fe, Co, Ni, and Cu) for eNO3RR. Except for CuNC, which selectively produced nitrite, all catalysts exhibited Faradaic efficiencies (FE) for ammonia exceeding 50%. NiNC demonstrated the highest performance (FE of 78.0 ± 2.9% at −0.4 V versus reversible hydrogen electrode (RHE) at pH 13 and maximum ammonia production rate of 615.7 ± 176.5 µmol·h−1·, corresponding to an energy efficiency of 15.1 ± 1.4% at −0.6 VRHE), followed by CoNC. In situ Synchrotron X‐ray fluorescence (SXRF) mapping at various cathodic potentials (from open circuit potential to 0.0 VRHE and then −0.6 VRHE at 100 mV steps) revealed significant mobility of Ni within the carbon matrix, leading to the formation of metallic clusters from 0.0 VRHE. Similar in situ metal clustering is observed for CoNC. Structure‐activity plots are generated from both MNC literature and results obtained here, finding a clear trend between OH binding energy and turnover frequency, with the high activity of NiNC and CoNC in this work explained by their stronger OH binding in the metallic structure compared to their SAC coordination. This work therefore, reveals the structure‐activity‐stability of MNCs for eNO3RR and provides a simple descriptor for identifying highly active eNO3RR catalysts and their in situ structural evolution. KW - Single atom KW - Nitrate reduction KW - Structure-activity-selectivity KW - In situ PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640353 DO - https://doi.org/10.1002/advs.202510282 SN - 2198-3844 VL - 12 IS - 39 SP - 1 EP - 14 PB - Wiley-VCH CY - Weinheim AN - OPUS4-64035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rua-Ibarz, Ana A1 - Nakadi, Flávio V. A1 - Bolea-Fernandez, Eduardo A1 - Bazo, Antonio A1 - Battistella, Beatrice A1 - Matiushkina, Anna A1 - Resch-Genger, Ute A1 - Abad Andrade, Carlos Enrique A1 - Resano, Martín T1 - Discrete entity analysis via microwave-induced nitrogen plasma–mass spectrometry in single-event mode N2 - In this work, single-event microwave-induced nitrogen plasma–mass spectrometry (single-event MINP-MS) was evaluated for the first time for the analysis of discrete entities such as nanoparticles, biological cells, and microplastics. Nitrogen (N2) effectively overcomes Ar-based polyatomic interferences, enabling (ultra)trace element determination of Fe and Se using their most abundant isotopes, 56Fe (91.66%) and 80Se (49.82%). Iron oxide nanoparticles (Fe2O3 NPs) ranging from 20 to 70 nm were accurately characterized, with excellent agreement with established sizing techniques, such as transmission electron microscopy (TEM) and dynamic light scattering (DLS). A limit of detection (LoD) of 8.6 ag for Fe─equivalent to an LoDsize of 19 nm for Fe2O3─was achieved, which is significantly lower than recent values reported for high-end quadrupole-based ICP-MS. Selenium nanoparticles (SeNPs) of 150 and 250 nm were also accurately characterized, without the N2-based plasma experiencing issues handling relatively large metallic NPs (linearity, R2 = 0.9994). Se-enriched yeast cells (SELM-1 certified reference material) were successfully analyzed via single-cell MINP-MS using external calibration based on SeNPs and a transport efficiency-independent approach. In addition, 2–3 μm polystyrene (PS) and polytetrafluoroethylene (PTFE) were accurately sized by monitoring 12C+, confirming the method’s suitability for handling micrometer-sized polymeric materials (microplastics). The average duration of individual events (680 ± 160 μs) suggests that the digestion of individual entities in N2-based plasmas is comparable to that in Ar-based plasmas. These results open new avenues for this instrumentation as an alternative to ICP ionization sources, also in the context of discrete entity analysis. KW - Microwave-Induced Nitrogen Plasma KW - Discrete entity analysis KW - Particle/droplet event counting KW - Comparison to SP-ICP-MS methodologies KW - Nitrogen plasma vs. argon ICP trade-offs KW - Trace elemental quantification at the single-entity level KW - Time-resolved mass spectrometry for discrete entities PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643825 DO - https://doi.org/10.1021/acs.analchem.5c04341 SN - 0003-2700 SP - 1 EP - 8 PB - American Chemical Society (ACS) AN - OPUS4-64382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Morcillo, Dalia A1 - Winckelmann, Alexander A1 - Oelze, Marcus A1 - Leonhardt, Robert A1 - Schmidt, Anita A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Vogl, Jochen A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - Exploring Age-Induced Lithium Isotope Fractionation in Lithium-Ion Batteries using Microwave-Induced Cold Nitrogen Plasma Mass Spectrometry N2 - This study explores Microwave-Inductively Coupled Atmospheric-pressure Plasma Mass Spectrometry (MICAP-MS) as a cost-effective alternative to Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) for analyzing lithium isotopic composition in lithium-ion batteries (LIBs). We investigate the performance of MICAP-MS in measuring Li isotope ratios in new and aged commercial lithium cobalt oxide (LCO) batteries. Our results show that MICAP-MS, operating under cold plasma conditions at 800 W with an 8 mm torch position, achieves results metrologically compatible with MC-ICP-MS, with a precision ranging from 0.6‰ to 3.4‰ for δ7Li values. MICAP-MS benefits from a dielectric resonator for uniform plasma, better ion velocity control, and higher energy efficiency. Optimal settings were identified with dwell times of 10 ms for 6Li and 1 ms for 7Li. The study of LIBs revealed that 6Li migrates towards the anode over multiple charge–discharge cycles, causing 7Li to accumulate in the cathode, a fractionation effect that becomes more pronounced with prolonged cycling. MICAP-MS provides a cost-effective, precise alternative to MC-ICP-MS, with lower operational costs and enhanced portability, advancing the study of isotopic fractionation and aging in lithium-ion batteries. KW - MICAP-MS KW - Lithium KW - Battery aging KW - Lithium isotopes KW - Nitrogen plasma KW - Isotope fractionation KW - lithium cobalt oxide KW - LCO PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643777 DO - https://doi.org/10.1039/d4ja00324a SN - 0267-9477 SP - 1 EP - 11 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abad Andrade, Carlos Enrique A1 - Jegielka, Dennis A1 - Aloysius, Allen A1 - Recknagel, Sebastian T1 - SI-traceable total analysis of nitrate and nitrite by isotope dilution optical spectroscopy and its application to Berlin surface waters N2 - Accurate nitrate and nitrite data support water-quality regulation, yet routine methods rely on external calibration and rarely achieve SI traceability. We report a calibration-free determination of nitrate and nitrite by combining isotope dilution with high-resolution continuum-source graphite furnace molecular absorption spectrometry (ID-HR-CS-GF-MAS). A 15N-enriched nitrate spike (its concentration verified by reverse isotope dilution against the standard reference material NIST 3185) provides the SI link, and it is gravimetrically added to samples; nitrate and residual nitrite are converted in situ to nitric oxide (NO), whose 215 nm band is recorded at a pixel resolution of λ/Δλ ≈ 140 000. The 0.2127 nm shift between 14NO and 15NO electronic spectra is resolved, and a three-latent-variable partial least squares regression model yields the 15N/14N ratio with 0.3% precision. Instrumental LoD values of 4.8 ng (14N) and 3.2 ng (15N) translate to a method LoD of 4.8 ng of nitrogen (equivalent to 1.05 mg L−1 NO3− for a 20 μL aliquot). The furnace program allows for successive drying/pyrolysis loops, so additional 20 μL aliquots can be layered onto the graphite platform. Alternatively, a 10 mL anion-exchange solid-phase extraction step concentrates nitrate and nitrite fivefold, allowing for the analysis of even lower sample concentrations. Results for four certified reference materials (2.9 to 1000 mg L−1 NO3−) agreed with certified values, giving relative expanded uncertainties of 2 to 4%. Analysis of twenty Berlin surface-water samples revealed concentrations ranging from 0.10 to 7.3 mg L−1 NO3−, indicating that the Panke River and Teltow Canal are the primary sources of nitrogen. ID-HR-CS-GF-MAS thus delivers ID-MS-level accuracy in a few minutes per run with bench-top optics, and, with optional on-platform or SPE pre-concentration, extends SI-traceable nitrate/nitrite monitoring into the low-ng regime. KW - Isotope dilution KW - Nitrate and nitrite determination KW - SI-traceable quantification KW - Calibration-free analysis KW - Water quality KW - Berlin surface waters KW - NO molecular absorption bands PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643785 DO - https://doi.org/10.1039/D5JA00252D SN - 0267-9477 VL - 40 IS - 10 SP - 2692 EP - 2701 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64378 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Marschall, Niklas A1 - Murugan, Jegatheesan A1 - Darvishi Kamachali, Reza T1 - Incorporating elasticity into the thermodynamics and phase diagrams of multi-component systems N2 - Elastic energy plays a critical role in determining phase stability in compositionally complex alloys. However, quantifying elastic contributions in multi-component systems and incorporating them into phase diagram construction remain challenging. In this study, we present a generalized elastic energy formalism tailored for multi-component alloys, which can be directly and efficiently integrated with CALPHAD thermodynamic databases and existing frameworks such as Thermo-Calc (Andersson et al., 2002), Pandat (Cao et al., 2009) or FactSage (Bale et al., 2016). This elasticity formalism can also be introduced as a post-processing layer in open-source software such as pyCALPHAD (Otis and Liu, 2017) and Kawin (Ury et al., 2023) , enabling elastic assessments in multi-component systems. We apply our framework for constructing the phase diagram of quinary Fe–Mn–Ni–Co–Cu alloy system, utilizing convex hull and Hessian matrix under elastic considerations. Our results reveal that incorporating elastic energy leads to an expansion of both the spinodal region and the miscibility gap. These are governed by the intricate interplay of chemical and elastic driving forces: We found that Mn and Ni contribute strongly to chemical stabilization, while Cu and Co tend to destabilize the alloy, especially at low Mn concentrations. The stabilizing effect of Fe is also pronounced in Mn-deficient regions. Acting as a destabilizing factor, the elastic energy is primarily driven by the presence of Mn, underscoring its multifaceted role in thermodynamic stability. In Mn-rich compositions, Cu markedly reduces the elastic energy contribution. Combined with CALPHAD infrastructures, the current framework offers a practical pathway to improve the predictive accuracy of phase stability and transformations in complex multi-component alloys. KW - Elastic energy KW - HEA KW - CALPHAD KW - Elastic spinodal KW - Elastic miscibility gap KW - Elastic phase diagram PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643339 DO - https://doi.org/10.1016/j.mtla.2025.102546 SN - 2589-1529 VL - 44 SP - 1 EP - 18 PB - Elsevier CY - Amsterdam, Niederlande AN - OPUS4-64333 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tidblad, Johan A1 - Moya Núñez, Alice A1 - de la Fuente, Daniel A1 - Ebell, Gino A1 - Flatlandsmo Berglen, Tore A1 - Grøntoft, Terje A1 - Hans, Ulrik A1 - Christodoulakis, Ioannis A1 - Kajánek, Daniel A1 - Kreislová, Kateřina A1 - Kwiatkowski, Lech A1 - La Torreta, Teresa A1 - Lutze, Rafał A1 - Pinar Larrubia, Guadalupe A1 - Pintus, Valentina A1 - Prange, Michael A1 - Spezzano, Pasquale A1 - Varotsos, Costas A1 - Verney-Carron, Aurélie A1 - Vuorio, Tiina A1 - Yates, Tim T1 - Corrosion and Soiling in the 21st Century: Insights from ICP Materials and Impact on Cultural Heritage N2 - This paper reviews results published by the International Co-operative Programme on Effects on Materials including Historic and Cultural Monuments (ICP Materials) with emphasis on those obtained after the turn of the century. Data from ICP Materials come from two main sources. The first is through exposures of materials and collection of environmental data in a network of atmospheric exposure test sites mainly distributed across Europe. Corrosion of carbon steel has continued to decrease during the period 2000–2020 but corrosion of zinc only up until 2014, and the trend in zinc corrosion is only visible when examining four-year data. Surface recession of limestone as well as soiling of modern glass show no decreasing trend during 2000–2020. The second is through case studies performed at heritage sites across Europe. Risk analysis of corrosion and soiling for twenty-six sites indicate that currently soiling is a more significant maintenance trigger than corrosion. Costs for maintaining heritage sites are substantial and costs attributable to air pollution is estimated from 40% to as much as 80% of the total cost. Future directions of the program are work on effects of particulate matter, improving the scientific basis for the work, and making the monitoring data publicly available. KW - Corrosion KW - Atmospheric corrosion KW - Soiling PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-644651 DO - https://doi.org/10.3390/cmd6040054 SN - 2624-5558 VL - 6 IS - 4 SP - 1 EP - 25 PB - MDPI AG AN - OPUS4-64465 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Arai, Marylyn Setsuko A1 - Machado, Thales Rafael A1 - da Silva, Beatriz Giacomelli Rodrigues A1 - Vilela, Raquel Riciati do Couto A1 - de Camargo, Andrea Simone Stucchi A1 - Zucolotto, Valtencir T1 - Biomimetic Upconverting Nanoplatforms for Glioblastoma Bioimaging and Targeted Therapy N2 - Infectious bacterial diseases, intensified by antibiotic resistance, cause millions of deaths annually and pose risks beyond human health, including water and food contamination. Current diagnostics are often slow, require complex equipment, and lack specificity, highlighting the need for rapid and reliable detection methods. To address this, we developed a luminescent sensor based on NaYF4 upconverting nanoparticles (UCNPs) doped with Er3+ or Tm3+, coated with COOH-PEG4-COOH, and functionalized with vancomycin (Van) or polymyxin-B (Poly) to selectively target Gram-positive and Gram-negative bacteria, respectively. Gold nanoparticles (AuNPs) served as quenchers, enabling a ratiometric “turn-on” mechanism: upon bacterial binding, the UCNP emission, initially quenched by AuNPs, was partially restored. This allowed differentiation through changes in the green/red (G/R) ratio for Er-UCNP@PEG4-Van and the blue/red (B/R) ratio for Tm-UCNP@PEG4-Poly. The sensor distinguished between Gram-positive and Gram-negative bacteria over a wide concentration range (0.05 to 5 × 105 CFU/mL) and showed high correlation with actual bacterial counts (r = 0.99 for S. aureus, r = 0.91 for E. coli). This platform is a potential fast, selective, and reliable tool for bacterial detection in clinical and environmental settings. KW - Glioblastoma KW - Homotypic targeting KW - Cell membrane coating KW - Upconverting nanoparticles KW - Temozolamide KW - Near infrared bioimaging KW - Drug delivery PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652808 DO - https://doi.org/10.1021/acsanm.5c04567 SN - 2574-0970 VL - 10 IS - 39 SP - 1 EP - 13 PB - American Chemical Society (ACS) AN - OPUS4-65280 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klinge, A A1 - Mönig, J A1 - Ziegert, C A1 - Richter, Matthias A1 - Kalbe, Ute A1 - Horn, Wolfgang A1 - Röhlen, U A1 - Rauscher, S A1 - Roswag-Klinge, E T1 - upMIN 100 – upcycling of mineral construction and demolition waste to substitute natural aggregates in earthen building materials N2 - The construction sector is one of the most resource-intensive sectors in Germany and is responsible for 40 % of CO2 emissions. Around 517 million tons of mineral raw materials are required annually for the construction of buildings in Germany. At the same time, mineral construction waste was the largest material flow at 229.3 million tons (2020). The rates of construction and demolition waste (CDW) recycling have increased since 2000, especially for mineral waste. Nevertheless, the majority of recycled aggregates are used in technically largely unregulated applications (e.g. road construction). This downcycling leads to a loss of valuable resources for technically and economically valuable applications. The upMIN 100 research project is investigating the question of whether and to what extent recycled CDW is suitable as an additive an binder in earthen building materials. The focus is placed on grain sizes of < 2 mm, which are currently predominantly landfilled, as there are at present no regulations for their use in building products. The soil matrix of earthen building materials however, naturally contains of different grain sizes, whith < 2mm – 0,063 for aggregates and < 0.063 mm as a binder. Therefore, the focused grain sizes (sand, clay and silt) could have a high usage potential. In order to enable the use of CDW, the technical feasibility must be ensured, quality requirements for source materials (e.g. threshold values for pollutants in terms of health and environmental compatibility and hazardous substances) and permissible proportions of recycled aggregates must be defined. Two different building material developments (earth blocks and -plaster)were used to assess both, the technical feasibility as well the pollutant content of the recycled aggregate and its final emissions into the indoor air. For both materials two mixtures could be established, that also meet the mechanical specifications according to the DIN standard, such as the compressive strength. A method was developed to design material mixtures with a high amount of CDW that comply with the defined limit values. The mixtures reached a recycling rate of 28 % with high mechanical properties and 70 % with minimum strength requirements. KW - Mineral waste KW - Upcycling KW - Earthen building product KW - Circular construction PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652831 DO - https://doi.org/10.1088/1755-1315/1554/1/012084 SN - 1755-1307 VL - 1554 IS - 1 SP - 1 EP - 9 PB - IOP Publishing AN - OPUS4-65283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hallier, Dorothea C. A1 - Radnik, Jörg A1 - Dietrich, Paul M. A1 - Seitz, Harald A1 - Hahn, Marc Benjamin T1 - Radiation damage to amino acids, peptides and DNA-binding proteins: the influence of water directly monitored by X-ray photoelectron spectroscopy N2 - Ionizing radiation damage to biomolecules plays a crucial role in radiotherapy as a cancer treatment. Among these, DNA-binding proteins are of particular interest due to their pivotal roles in shielding DNA and facilitating its repair. Hence, in this study, we present first-ever recorded data of radiation damage to a protein monitored directly with near-ambient pressure (NAP) X-ray photoelectron spectroscopy (XPS) under a water atmosphere. This surface sensitive technique was used to in situ damage and probe gene-V protein (G5P, a model DNA-binding protein) under wet NAP conditions and dry vacuum (UHV) conditions to determine the effect of water on the radiation response. In addition, the X-ray radiation damage to selected pure amino acids and short homopeptides was determined to better understand the variety of damage mechanisms within the complex protein. In dry samples, drastic chemical changes were detected in all biomolecules dominated by fragmentation processes. Here, the breakage of peptide bonds in the peptides and the protein are dominant. Surprisingly, hydration – despite introducing additional indirect damage pathways via water radiolysis – led to a reduction in overall radiation damage. This behaviour was attributed to hydration-dependent changes in reaction rates and respective deexcitation and damaging channels within the molecules and secondary species such as low-energy (LEE), (pre)-hydrated/(pre)-solvated electrons and radical species such as hydroxyl radicals. KW - Radiation damage KW - (Near-ambient pressure) X-ray photoelectron spectroscopy KW - Ultra-high vacuum PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-647565 DO - https://doi.org/10.1039/d5cp01887k VL - 27 IS - 48 SP - 1 EP - 22 PB - Royal Society of Chemistry AN - OPUS4-64756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Liu, Cong A1 - Aumont, Cédric A1 - Mikhailova, Alina A. A1 - Audisio, Tracy A1 - Hellemans, Simon A1 - Weng, Yi-Ming A1 - He, Shulin A1 - Clitheroe, Crystal A1 - Wang, Zongqing A1 - Haifig, Ives A1 - Sillam-Dussès, David A1 - Buček, Aleš A1 - Tokuda, Gaku A1 - Šobotník, Jan A1 - Harrison, Mark C. A1 - McMahon, Dino P. A1 - Bourguignon, Thomas T1 - Unravelling the evolution of wood-feeding in termites with 47 high-resolution genome assemblies N2 - Termites are a lineage of social cockroaches abundant in tropical ecosystems where they are key decomposers of organic matter. Despite their ecological significance, only a handful of reference-quality termite genomes have been sequenced, which is insufficient to unravel the genetic mechanisms that have contributed to their ecological success. Here, we perform sequencing and hybrid assembly of 45 taxonomically and ecologically diverse termites and two cockroaches, resulting in haplotype-merged genome assemblies of 47 species, 22 of which were near-chromosome level. Next, we examine the link between termite dietary evolution and major genomic events. We find that Termitidae, which include ~80% of described termite species, have larger genomes with more genes and a higher proportion of transposons than other termites. Our analyses identify a gene number expansion early in the evolution of Termitidae, including an expansion of the repertoire of CAZymes, the genes involved in lignocellulose degradation. Notably, this expansion of genomes and gene repertoires coincided with the origin of soil-feeding in Termitidae and remained unchanged in lineages that secondarily reverted to a wood-based diet. Overall, our sequencing effort multiplies the number of available termite genomes by six and provides insights into the genome evolution of an ancient lineage of social insects. KW - Comparative genomics KW - Entomology KW - Genome evolution KW - Phylogenetics PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651719 DO - https://doi.org/10.1038/s41467-025-65969-5 SN - 2041-1723 VL - 16 SP - 1 EP - 14 PB - Springer Science and Business Media LLC AN - OPUS4-65171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Amiri, Hesam A1 - Nikookhesal, Aidin A1 - Murugan, Divagar A1 - Scholz, Stefan A1 - Frentzen, Michael A1 - Cao, Yuan A1 - Nickl, Philip A1 - Radnik, Jörg A1 - Stockmann, Jörg M. A1 - Vu, Xuan-Thang A1 - Narayanan, Madaboosi S. A1 - Knoch, Joachim A1 - Ingebrandt, Sven A1 - Adeli, Mohsen A1 - Pachauri, Vivek T1 - High precision correlative analysis of dielectric behavior evolution and anisotropy in graphene oxide thin film as a function of thermal annealing parameters N2 - Graphene oxide (GO) and reduced graphene oxide (rGO) attract keen interest from different science and technology sectors owing to their tunable material characteristics dependent on C/O ratio. Thermal annealing in different gaseous environments serves as an effective approach to manipulate the C/O ratio in graphitic lattice, making it suitable for various electronic, optical and composites applications. Despite regular use of thermal annealing, systematic studies on dielectric properties evolution in GO against different annealing parameters remain elusive. This work reports on a reliable approach that adopts a joint Raman Spectroscopy, Mueller Matrix Spectroscopic Ellipsometry (MMSE) and high-precision electrical impedance spectroscopy (HP-EIS) framework for studying the evolution of dielectric behavior and anisotropies in GO. The experimental platform involved lithography-defined GO patterns connected to metal microelectrodes and glass passivation for protection from gaseous environments during annealing and measurements using Raman, MMSE and HP-EIS. The presented study delineates the effects of annealing parameters such as temperature, heating rate, and gaseous environment on GO permittivity. Novel findings include the discovery of a direct relationship between heating rate and dielectric properties, as well as determination of vertical limitation of MMSE for permittivity distribution characterization in GO, for the first time, to be around 8 nm. KW - Thermal annealing KW - Reduced graphene oxide KW - Thin films KW - 2D materials KW - Spectroscopic ellipsometry PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652428 DO - https://doi.org/10.1016/j.nwnano.2025.100130 SN - 2666-9781 VL - 11 SP - 1 EP - 10 PB - Elsevier Ltd. AN - OPUS4-65242 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tavernaro, Isabella A1 - Rajotte, Isabelle A1 - Thibeault, Marie-Pier A1 - Sander, Philipp C. A1 - Kodra, Oltion A1 - Lopinski, Gregory A1 - Radnik, Jörg A1 - Johnston, Linda J. A1 - Brinkmann, Andreas A1 - Resch-Genger, Ute T1 - Quantifying surface groups on aminated silica nanoparticles of different size, surface chemistry, and porosity with solution NMR, XPS, optical assays, and potentiometric titration N2 - We assessed the quantification of surface amino functional groups (FGs) for a large set of commercial and custom-made aminated silica nanoparticles (SiO2 NPs) with sizes of 20–100 nm, prepared with different sol–gel routes, different amounts of surface amino FGs, and different porosity with four methods providing different, yet connected measurands in a bilateral study of two laboratories, BAM and NRC, with the overall aim to develop standardizable measurements for surface FG quantification. Special emphasis was dedicated to traceable quantitative magnetic resonance spectroscopy (qNMR) performed with dissolved SiO2 NPs. For the cost efficient and automatable screening of the amount of surface amino FGs done in a first step of this study, the optical fluorescamine assay and a potentiometric titration method were utilized by one partner, i.e., BAM, yielding the amount of primary amino FGs accessible for the reaction with a dye precursor and the total amount of (de)protonatable FGs. These measurements, which give estimates of the minimum and maximum number of surface amino FGs, laid the basis for quantifying the amount of amino silane molecules with chemo-selective qNMR with stepwise fine-tuned workflows, involving centrifugation, drying, weighting, dissolution, measurement, and data evaluation steps jointly performed by BAM and NRC. Data comparability and relative standard deviations (RSDs) obtained by both labs were used as quality measures for method optimization and as prerequisites to identify method-inherent limitations to be later considered for standardized measurement protocols. Additionally, the nitrogen (N) to silicon (Si) ratio in the near-surface region of the SiO2 NPs was determined by both labs using X-ray photoelectron spectroscopy (XPS), a well established surface sensitive analytical method increasingly utilized for microparticles and nano-objects which is currently also in the focus of international standardization activities. Overall, our results underline the importance of multi-method characterization studies for quantifying FGs on NMs involving at least two expert laboratories for effectively identifying sources of uncertainty, validating analytical methods, and deriving NM structure–property relationships. KW - Advanced Materials KW - Amino Groups KW - Calibration KW - Characterization KW - Functional groups KW - Method Comparison KW - Nano Particle KW - Validation KW - XPS KW - Optical Assay KW - Quantification KW - Surface Analysis KW - Reference Materials KW - Synthesis KW - Fluorescence PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-649992 DO - https://doi.org/10.1039/d5na00794a VL - 7 IS - 21 SP - 6888 EP - 6900 PB - Royal Society of Chemistry AN - OPUS4-64999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schusterbauer, Robert A1 - Schünemann, Pia A1 - Nickl, Philip A1 - Er, Jasmin A1 - Kämmer, Victoria A1 - Junge, Florian A1 - Fazzani, Salim A1 - Mrkwitschka, Paul A1 - Meermann, Björn A1 - Haag, Rainer A1 - Donskyi, Ievgen T1 - Bifunctional Reduced Graphene Oxide Derivatives for PFOA Adsorption N2 - Innovative materials are crucial for removing persistent pollutants per‐ and polyfluorinated alkyl substances (PFAS) from water. Here, a novel bifunctional reduced graphene oxide (TRGO) adsorbent is developed and characterized by advanced surface sensitive methods. Compared to pristine TRGO, the functionalized TRGO shows markedly improved PFAS removal efficiency and demonstrates strong potential for water purification applications. KW - Adsorber KW - PFAS KW - HR-CS-GFMAS PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651238 DO - https://doi.org/10.1002/ceur.202500240 SN - 2751-4765 SP - 1 EP - 7 PB - Wiley VHC-Verlag AN - OPUS4-65123 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Smerechuk, Anastasiia A1 - Guilherme Buzanich, Ana A1 - Büchner, Bernd A1 - Wurmehl, Sabine A1 - Morrow, Ryan T1 - Synthesis and properties of Sr2La2NiW2O12, a new S = 1 triangular lattice magnet N2 - Magnetic materials featuring triangular arrangements of spins are frequently investigated as platforms hosting magnetic frustration. Hexagonal perovskites with ordered vacancies serve as excellent candidates for two-dimensional triangular magnetism due to the considerable separation of the magnetic planes. In this work, the effects of chemical pressure on the ferromagnetic ground state of Ba2La2NiW2O12 by substitution of Ba2+ with Sr2+ to produce Sr2La2NiW2O12 are investigated. The two materials are characterized using synchrotron-based XRD, XANES and EXAFS in addition to magnetometry in order to correlate their crystal structures and magnetic properties. Both materials form in space group R 3, yet as a result of the enhanced bending of key bond angles due to the effects of chemical pressure, the T C value of the magnetic Ni2+ sublattice is reduced from ∼6 K in Ba2La2NiW2O12 to 4 K in Sr2La2NiW2O12. KW - XRD KW - Magnetic materials KW - EXAFS PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652982 DO - https://doi.org/10.1107/S2052520624007091 SN - 2052-5206 VL - 80 IS - 5 SP - 467 EP - 473 PB - International Union of Crystallography (IUCr) AN - OPUS4-65298 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wosniok, Aleksander A1 - Schukar, Marcus A1 - Breithaupt, Mathias A1 - Kriegsmann, Andreas T1 - Distributed Fibre Optic Monitoring of Hydrogen Storage Composite Pressure Vessels for Automotive Use N2 - We present our research work on the condition monitoring of hydrogen storage composite pressure vessels using distributed fibre optic sensors. The sensing fibres are integrated into the composite structure by wrapping them over the polymer liner in the helical and circumferential direction during the manufacturing process of the carbon fibre reinforced polymer. The following use of optical backscatter reflectometry allows for continuous condition monitoring and precise detection and localization of structural damages during the entire service life. To account for the time-dependent strength degradation of the composite pressure vessels, both slow burst and ambient hydraulic cycling tests, respectively, were conducted on five 70 MPa pressure vessels with integrated fibre optic sensors. The results achieved via distributed fibre optic strain sensing demonstrate a near linear strain response to pressure suitable for sensitive condition monitoring and confirm the required robustness of the selected sensor solution. T2 - DGZfP-Jahrestagung 2025 CY - Berlin, Germany DA - 26.05.2025 KW - Distributed fibre optic sensor (DFOS) KW - Composite pressure vessel KW - Optical backscatter reflectometry KW - Slow burst test KW - Ambient hydraulic cycling test PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653067 DO - https://doi.org/10.58286/32344 SP - 1 EP - 8 PB - NDT.net AN - OPUS4-65306 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stohl, Leonie A1 - Manninger, Tanja A1 - Dehn, Frank A1 - von Werder, Julia T1 - Understanding bioreceptivity of concrete: material design and characterization N2 - The climate crisis is driving an increasing demand for ecologically oriented concepts. In the building sector, this demand includes not only the use of environmentally friendly materials but also the greening of urban areas. One promising approach is the development of bioreceptive concrete façades, which support the growth of green biofilms directly on their surfaces. These innovative façades are anticipated to deliver benefits comparable to those of macroscopically greened façades, such as enhanced biodiversity and improved air quality, while offering the advantages of being more self-sustaining and stable systems once fully established. However, the development of bioreceptive concrete presents substantial challenges. Due to the interdisciplinarity and novelty of this field, standardized methods for material characterization and bioreceptivity assessment are currently lacking. This study proposes an approach for evaluating surface properties crucial for bioreceptivity, developed on differently structured samples of ultra-high-performance concrete (UHPC). Existing methods and standards from concrete technology are critically reviewed and, where necessary, modified to meet the unique requirements of measuring bioreceptive material properties. Special attention is given to the surface pH value and water retention characteristics, as these are essential for promoting microbial growth and ensuring the long-term stability of green biofilms. The observed surface characteristics vary according to the imprinted surface structures, offering a spectrum of material properties and enabling the evaluation of their impact on bioreceptivity. The findings presented form the foundation for subsequent laboratory weathering experiments, which will be discussed in a complementary publication. KW - Bioreceptivity KW - Concrete KW - Biofilm PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-648180 DO - https://doi.org/10.1617/s11527-025-02863-y SN - 1359-5997 VL - 58 IS - 10 SP - 1 EP - 12 PB - Springer Science and Business Media LLC AN - OPUS4-64818 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Casperson, Ralf A1 - Heideklang, René A1 - Myrach, Philipp A1 - Onel, Yener A1 - Pelkner, Matthias A1 - Pohl, Rainer A1 - Stegemann, Robert A1 - Ziegler, Mathias A1 - Kreutzbruck, Marc T1 - Vergleich konventioneller und neuer Oberflächenprüfverfahren für ferromagnetische Werkstoffe N2 - Sicherheitsrelevante und zyklisch hoch belastete Bauteile erfordern zur Vermeidung von kostenintensiven Ausfällen besonders stabile Prozessparameter. Bereits sehr kleine Randzonenfehler können unter zyklischer Bauteilbelastung zu Risswachstum und letztendlich zum Bauteilversagen führen. Die frühzeitige Erkennung von Randzonenfehler in Hochleistungsbauteilen wie z.B. Zahnräder, Ritzelwellen und Kurbelwellen erfordert daher eine leistungsfähige zerstörungsfreie Oberflächenrissprüfung, die es ermöglicht in den hochbeanspruchten Funktionsflächen auch Härterisse, Schleifrisse oder Zundereinschlüsse zu detektieren. Hierzu sind in den letzten Jahren einige neue, innovative Oberflächenprüfverfahren wie die laserangeregte Thermografie und die Streuflussprüfung mit hochauflösenden GMR-Sensoren oder magnetooptischen Verfahren entwickelt worden. Zusätzlich zur hohen Empfindlichkeit zeichnen sich diese innovativen Verfahren durch einen schnellen und teils auch berührungslosen Einsatz aus. Da die noch relativ neu-en Verfahren naturgemäß noch nicht normativ verankert sind, wurden auch bereits erste Validierungen durchgeführt. Um die Leistungsfähigkeit der Verfahren eingehend zu untersuchen, erfolgten Testreihen an verschiedenen Testkörpern in Bezug auf Ortsauflösung, Empfindlichkeit, Automatisierung und Bewertung der Messsig-nale. Neben den neuen Verfahren und ihren ersten Schritten hin zur Validierung kamen als Referenz auch die „klassischen“ Verfahren der Magnetpulver- und Wirbelstromprüfung zum Einsatz, deren Leistungsfähigkeit durch angepasste Sondenentwicklung auch für sehr kleine Oberflächendefekte nochmals unter Beweis gestellt wurde. Zusätzlich wurde an einigen Testkörpern eine hochauflösende CT durchgeführt. Die Ergebnisse dieses Vergleiches werden vorgestellt und Möglichkeiten sowie Grenzen der einzelnen Verfahren herausgearbeitet. T2 - DACH-Jahrestagung 2015 CY - Salzburg, Austria DA - 11.05.2015 KW - Zerstörungsfreie Prüfung KW - Oberflächenprüfung KW - Vergleichskörper 1 KW - Sichtprüfung KW - Magnetpulverprüfung KW - Streuflussprüfung KW - Farbeindringprüfung KW - Wirbelstromprüfung KW - Thermografie KW - Radiografie PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-344262 SN - 978-3-940283-68-9 IS - DGZfP BB 152 SP - Mi.2.B.4, 1 EP - 11 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-34426 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jonietz, Florian A1 - Krankenhagen, Rainer A1 - Noack, M. A1 - Gensecke, K. A1 - Wiedenmann, E. T1 - 3D-Formbestimmung mit integrierter thermografischer Qualitätsprüfung N2 - Sowohl die 3D-Formbestimmung als auch die Thermografie sind Verfahren der Qualitätssicherung. Im vorgestellten Projekt wird versucht, die beiden Methoden zusammenzuführen. Das Prinzip des für die Formbestimmung verwendeten 3D-Scanners beruht auf dem bereits bekannten Verfahren der Streifenlichtprojektion. Die Neuartigkeit des hier verwendeten 3D-Scanners besteht darin, dass nicht im sichtbaren, sondern im infraroten Spektralbereich gearbeitet wird. Dadurch wird es möglich, nicht die Reflexion, sondern die Wärmestrahlung des Prüfobjektes nach Absorption der eingebrachten Strahlung auszuwerten. Dies ermöglicht, auch optisch „nicht-kooperative“ Oberflächen zu erfassen. Die Anregung mit Wärmestrahlung stellt das Bindeglied zum Verfahren der aktiven Thermografie für die Detektion verdeckter Schäden dar. Bei letzterem Verfahren wird der Wärmestau über Defekten beim Eindringen der Wärme in die Tiefe des Materials gemessen. Dabei stellen Defekte eine Störung des 3D-Scan-Verfahrens dar, während umgekehrt unregelmäßig geformte Oberflächen das thermografische Verfahren erschweren, d.h. der Messeffekt eines der Verfahren ist ein Störeffekt für das jeweils andere Verfahren. Es wird zum einen der Frage nachgegangen, inwieweit das 3D-Scan-Verfahren durch verdeckte thermische Defekte beeinträchtigt wird, und zum anderen die Möglichkeit untersucht, den vorhandenen 3D-Scanner auch für die aktive Thermografie einzusetzen. Es werden CFK-Proben mit künstlich eingebrachten thermischen Defekten untersucht und die Möglichkeiten und Grenzen der vorhandenen Messapparatur für die Defekterkennung aufgezeigt. T2 - DGZfP-Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - 3D-Formbestimmung KW - Thermografische Qualitätsprüfung KW - Streifenlichtprojektion KW - 3D-Scanner KW - Aktive Thermografie PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-407856 UR - https://jahrestagung.dgzfp.de/Portals/151//doc/Mi.1.A.3.pdf SN - 978-3-940283-85-6 VL - 162 SP - 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-40785 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mooshofer, H. A1 - Boehm, Rainer A1 - Heinrich, W. A1 - Fendt, K. A1 - Goldammer, M. A1 - Kolk, K. A1 - Vrana, J. T1 - Amplitudenbasierte Fehlergrößenbewertung mit SAFT: Auf dem Weg von der bildlichen Darstellung zum Messverfahren N2 - Die Größenbewertung von Anzeigen und die Bestimmung der Nachweisgrenze spielen bei der Ultraschallprüfung eine zentrale Rolle: Sie stellen sicher, dass kritische Ungänzen erfasst und bruchmechanisch behandelt werden können. Bei SAFT wurde bisher die Größe von Ungänzen dadurch bestimmt, dass die räumliche Anzeigenausdehnung im Rekonstruktionsergebnis ausgewertet wird, d.h. die Anzahl von Voxel über die sich eine Anzeige erstreckt. Auf diese Weise lassen sich jedoch nur Defektanzeigen bewerten, die größer oder gleich der Wellenlänge sind. Bei kleinen Defekten versagt diese Methode, d.h. es ist keine Größenbewertung möglich. Außerdem bietet diese Methode keine Aussage über die Nachweisgrenze des Verfahrens. Ein Hauptvorteil von SAFT gegenüber der konventionellen Ultraschallprüfung ist aber gerade die Verbesserung der Nachweisgrenze, denn SAFT steigert das Signal-Rausch-Verhältnis (SNR) gegenüber dem Gefügerauschen und reduziert statistisches Rauschen. Um diesen Hauptvorteil nutzen (und quantifizieren) zu können, wird für SAFT eine Methode zur Nachweisgrenzenbestimmung und zur Größenbewertung der Anzeigen kleiner Ungänzen benötigt. Neben ihrer räumlichen Ausdehnung lassen sich Anzeigen im SAFT-Ergebnis auch durch ihre Amplitude charakterisieren, wenn die Prüfkopfeigenschaften und die geometrischen Verhältnisse beim Scan berücksichtigt werden. Genauer gesagt durch die Amplitudensumme, in die - neben der Echoamplitude - auch die winkelabhängige Streucharakteristik eingeht. Im Folgenden wird dargelegt, dass sich die Amplitudensumme zur Nachweisgrenzenbestimmung und zur Größenbewertung kleiner Ungänzen eignet. Es wird der Zusammenhang zwischen der Amplitudensumme und der Größe von Ungänzen dargestellt, und es wird gezeigt, dass auch die Anzeigenposition und die Form des Prüfobjektes eine Rolle spielen können. Auf dieser Basis wird eine Methode zur Größenbestimmung kleiner Anzeigen im SAFT-Ergebnis entwickelt. Damit lässt sich das SAFT-Ergebnis als Ersatzfehlergröße darstellen, so wie das bei konventioneller Ultraschallprüfung z.B. mit Hilfe von AVG-Diagrammen erfolgt. Durch die Vervollständigung um die Größenbewertung ist SAFT nicht mehr nur ein bildgebendes Verfahren, sondern es kann vielmehr als vollwertiges Messverfahren dienen. T2 - DGZfP-Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - Synthetic aperture focussing technique (SAFT) KW - Defektgrößenbewertung KW - Gewichtete Amplitudensumme KW - Kleine Reflektoren PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-411571 SN - 978-3-940283-85-6 VL - 162 SP - 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-41157 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pelkner, Matthias A1 - Pohl, Rainer A1 - Erthner, Thomas A1 - Stegemann, Robert A1 - Kreutzbruck, Marc A1 - Sergeeva-Chollet, N. T1 - Eddy current testing with high-spatial resolution probes using MR arrays as receiver N2 - Magneto-resistive (MR) sensor arrays are suited for high resolution eddy current testing (ET) of aerospace components due to two significant advantages compared to conventional coil systems. First, to obtain high spatial resolution they can be manufactured down to the µm-regime without losing their outstanding field sensitivity. Secondly, MR technology has a relatively frequency-independent sensitivity in the range of common ET-frequencies thus providing a benefit for low frequency applications. This paper presents measurements using MR array probes consisting of 32 TMR-elements (tunnel magneto resistance), an ASIC, and subsequent readout components. A source for generating the eddy currents inside the material under test is also implemented onboard of the PCB. These probes were developed in the IMAGIC-project* for detection and imaging of surface breaking defects. The performance of the new sensor system has been investigated for several mock-ups, Aluminum and Titanium plate specimens having small adjacent boreholes with diameter of 0.44 mm and micro notches in the µm-range, respectively. To compare our results we used conventional eddy current probes. The MR sensor elements have a length of around 60 µm leading to a nearly 'point like' measurement. Neighbouring boreholes (depth 0.25 mm) with a separation of 0.6 mm between their centres could be resolved with a good SNR, and more important, the boreholes could be confidently distinguished using the TMR-probes. In case of conventional probes a reliable separation was not possible. In this paper we present the MR-ET-probes of the IMAGIC consortium and a comparison with conventional techniques. *The IMAGIC-project ('Integrated Magnetic imagery based on spIntronics Components', 2011 – 2014, project reference: 288381) was funded by the European Commission, Seventh Framework Programme. Further partners involved in the consortium beside BAM and CEA were INESC-ID and INESC-MN (Portugal), Sensitec GmbH (Germany), Tecnatom S.A. (Spain), and Airbus Group (France). T2 - 7th International symposium on NDT in aerospace CY - Bremen, Germany DA - 16.11.2015 KW - TMR KW - GMR KW - Sensor array KW - Eddy current testing (ET) KW - Aerospace PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-344254 SN - 978-3-940283-76-4 N1 - Serientitel: DGZfP-Proceedings – Series title: DGZfP-Proceedings IS - DGZfP-BB 156 SP - We.5.A.4, 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.v. (DGZfP) AN - OPUS4-34425 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Krankenhagen, Rainer A1 - Röllig, Mathias A1 - Hosseini, Seyed A1 - Heckel, Thomas A1 - Gaal, Mate A1 - Schadow, Florian A1 - Brackrock, Daniel A1 - Gower, M. A1 - Lodeiro, M. A1 - Baker, G. T1 - Quantitative Bewertung künstlicher und natürlicher Fehler in Faserverbundwerkstoffen mit aktiver Thermografie und Ultraschall N2 - Im EMRP-Projekt VITCEA werden komplementäre ZFP-Verfahren zur Prüfung von Faserverbundwerkstoffen weiterentwickelt und validiert. In diesem Beitrag werden Ergebnisse verschiedener Techniken der aktiven Thermografie und des Ultraschalls vorgestellt. Die Nachweisempfindlichkeiten bezüglich künstlicher und natürlicher Fehler mit unterschiedlichen lateralen Ausdehnungen und in verschiedenen Tiefen werden miteinander verglichen. T2 - DGZfP Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - CFK KW - GFK KW - Aktive Thermografie KW - Phased Array Ultraschall KW - Luftultraschall PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-410902 SN - 978-3-940283-85-6 VL - BB 162 SP - Di1B1, 1 EP - Di1B1, 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e. V. AN - OPUS4-41090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Gräßer, Patrick A1 - Wander, Lukas A1 - Zientek, Nicolai A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Kern, Simon T1 - Strangers in the Night—Smart Process Sensors in Our Current Automation Landscape N2 - The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors simplify their use and enable plug-and-play integration, even though they may appear to be more complex at first sight. Smart sensors enable concepts like self-diagnostics, self-calibration, and self-configuration/parameterization whenever our current automation landscape allows it. Here we summarize the currently discussed general requirements for process sensors 4.0 and introduce a smart online NMR sensor module as example, which was developed for an intensified industrial process funded by the EU’s Horizon 2020 research and innovation programme (www.consens-spire.eu). T2 - Eurosensors 2017 Conference CY - Paris, France DA - 03.09.2017 KW - Process Monitoring KW - Smart Sensors KW - CONSENS KW - Online NMR Spectroscopy KW - Mini-plant PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-415772 UR - http://www.mdpi.com/2504-3900/1/4/628 DO - https://doi.org/10.3390/proceedings1040628 VL - 1 SP - 628 EP - 631 PB - MDPI CY - Basel AN - OPUS4-41577 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Katsikini, M. A1 - Pinakidou, F. A1 - Paloura, E.C. A1 - Arvanitidis, J. A1 - Ves, S. A1 - Reinholz, Uwe A1 - Ppadomanolaki, E. A1 - Iliopoulos, E. T1 - Simulation of the EXAFS and Raman spectra of InxGa1-xN utilizing the equation of motion routine of FEFF8 N2 - A combined analysis of EXAFS and Raman spectra is applied for the study of InxGa1-xN alloys with 0.3 0.5MeV) X-rays and proved the applicability of the present technique to inspect thick carbon-fiber laminated components. In order to improve the inspection time and image quality of the backscatter image, we used high-resolution (180ìm) digital detector arrays (DDAs). At the end, important applications of the presented X-ray backscatter technique to the aerospace industry are discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray backscatter imaging KW - Twisted-slit collimator KW - NDT KW - Digital detector array (DDA) KW - Stringer KW - Aerospace applications PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322376 UR - https://www.ndt.net/?id=16431 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 8 PB - NDT.net CY - Kirchwald AN - OPUS4-32237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kind, Thomas T1 - Ortung von Spanngliedern zum schadensfreien Bohren im Rahmen von Ertüchtigungsmaßnahmen N2 - Am Beispiel der Ertüchtigung einer Brücke in Bremen wird gezeigt, wie mit den zerstörungsfreien Prüfverfahren (ZfP) Radar- und Ultraschall die genau Lage vorgespannte Bewehrung gefunden bzw. bestätigt werden kann. Im Rahmen von Ertüchtigungsmaßnahmen an Spannbetonbrücken werden häufig Kernbohrungen durchgeführt, die die vorhandenen Spannbewehrungen nicht beschädigen dürfen. Es wird die Vorgehensweise beschrieben, wie mit ZfP ein wesentlicher Beitrag geleistet wird, das Risiko einer Beschädigung zu minimieren und somit eine bessere Planungssicherheit für die Ertüchtigungsmaßnahmen zu schaffen. Dabei werden auch die Grenzen der beiden Verfahren aufgezeigt. T2 - Fachtagung Bauwerksdiagnose 2012 - Praktische Anwendungen zerstörungsfreier Prüfungen und Zukunftsaufgaben CY - Berlin, Germany DA - 23.02.2012 KW - Radar KW - Zerstörungsfreie Prüfung KW - Stahlbeton KW - Ultraschall PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-398225 SN - 978-3-940283-40-5 VL - 134 (Vortrag 11) SP - 1 EP - 7 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin, Germany AN - OPUS4-39822 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Ziegler, Mathias A1 - Kunert, M. A1 - Goldammer, M. T1 - Entwicklung von Referenzprobekörpern für die Standardisierung der Blitzthermografie N2 - Die aktive Thermografie wird in der Industrie zunehmend in verschiedenen Bereichen zur Qualitätssicherung, Zustandsdiagnose und Zustandsüberwachung eingesetzt. Bestehende Normen zur Thermografie beschreiben die Grundlagen, Geräte und Begriffe. In diesem Beitrag wird über ein Projekt berichtet, dessen Ziel die Erarbeitung einer Prüfnorm zur Blitzthermografie ist. Diese sollte neben der Auswahl geeigneter Gerätekomponenten, der Auswertungsverfahren und der Vorgehensweise bei der Prüfung auch die Beschreibung geeigneter Referenzprobekörper enthalten, die eine Bewertung der Messapparatur und eine Qualitätssicherung der Prüfung ermöglichen. T2 - Thermographie-Kolloquium 2011 CY - Stuttgart, Germany DA - 29.09.2011 KW - Aktive Thermografie KW - Blitzanregung KW - Prüfnorm KW - Referenzprobekörper PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246230 SN - 978-3-940283-36-8 VL - 130 SP - 1 EP - 7 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-24623 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartscher, M. A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Neuschaefer-Rube, U. T1 - Application of an industrial CT reference standard for cast freeform shaped workpieces N2 - Industrial computed tomography (CT) today is an important method to analyze defects and to measure the geometry of technical products. The measurement capability of industrial CT often depends on the knowledge of the measurement errors being present. Only with this knowledge, effective corrections are possible by manufacturers, or adapted measurement procedures become possible for the customers. Thus, there is the strong need to have adequate reference standards both for the assessment of general dependencies and for the measurement of task-specific effects. Especially the latter are difficult to assess. This paper shows the application of a versatile dismountable workpiece-near reference body for the use with CT. The reference standard was made from a miniaturized cast aluminium (one-)cylinder head. It can be dismounted into four segments, each featuring reference geometries which enable a registration of CT measured and other reference datasets (e.g. from tactile CMM). The reference standard embodies complex freeform surfaces which are a challenging measurement task for CT and other sensors. Here the application of the reference standard is the study of the influence of material mixes. This is realized by adding pieces of other materials which disturb the mono-material measurement. Results of the application of the reference standard are presented using data from industrial micro-CT systems and CMM reference data. A special emphasis is given on the workflow of the data processing and the data analysis. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Industrial reference standard KW - Computed tomographie KW - Freeform shaped workpieces PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-245532 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (We.4.3) SP - 1 EP - 12 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Badde, Aurelia A1 - Michaelis, Matthias A1 - Berger, U. A1 - Onel, Yener A1 - Meinel, Dietmar A1 - Goebbels, Jürgen T1 - Einsatz von mobilen Röntgenuntersuchungsmethoden im Museum - Zwei Fallbeispiele N2 - Zwei Bildhauermodelle aus dem Georg-Kolbe-Museum Berlin standen zur Restaurierung an. Das kleinere, 'Lucino' (1920), 41cm, wurde hochauflösend mit CT gemessen, da mittels CT sowohl der Herstellungsprozeß einer Gipsstatue als auch der innere Zustand, wie Ergänzungen, Klebungen und Armierungen, festgestellt werden können. Aus den CT Bildern ergab sich eine für die vorher vermutete Gipszusammensetzung ungewöhnliche innere Struktur. Mit einer Freihand bedienten Röntgenpistole zur Messung der Röntgenfluoreszenz wurde daraufhin die Zusammensetzung des Materials der Statuette als Terracotta bestimmt. Durch den Einsatz von Helium als Spülmittel konnten auch leichte Materialien nachgewiesen und so eine Unterscheidung zwischen Gips und gebranntem Ton durchgeführt werden. Aus den CT Daten wurde eine virtuelle Darstellung der äußeren Geometrie gewonnen. Ein damit versuchsweise erstelltes Replik (Rapid Prototyping, 3D-Drucker, TU-Berlin) entsprach nicht den Anforderungen des Museums zur Erstellung einer Gußform für eine Bronzekleinserie der Statuette. Die zweite Statue, die 'Große Nacht' (1930) ist mit ihrer Größe von 2,12m und aufgrund des durch korrodierende Metallarmierung verursachten Schadensbildes nicht mehr transportfähig. Eine in-situ Untersuchung mit dem mobilen Tomographen, der in den 1980ern zur Untersuchung von Bäumen gebaut und jetzt mit einem modernen Flachdetektor und einer Röntgenröhre ausgestattet ist, wird vorgestellt. Die Möglichkeiten acder in-situ CT für große Skulpturen werden anhand der Ergebnisse diskutiert. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 10.05.2010 KW - Mobile CT KW - Mobile RFA PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246956 UR - https://www.ndt.net/?id=10149 SN - 978-3-940283-26-9 VL - 122 SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-24695 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dey, Anika A1 - Casperson, Ralf A1 - Pohl, Rainer A1 - Thomas, Hans-Martin T1 - Die Wirbelstromprüfung als Hilfsmittel für die Schieneninstandhaltung N2 - Die zerstörungsfreie Oberflächenprüfung an verlegten Eisenbahnschienen mit Wirbelstrom hat in den letzten Jahren durch ständige Weiterentwicklung und Verifizierung enorm an Bedeutung gewonnen. Es wurde u.a. angestrebt zuverlässige Planungsgrößen für den Einsatz von Instandhaltungsmaßnahmen zu erhalten, durch deren gezielten Einsatz Risswachstum unterbunden werden kann. Die Ursache für das Wachstum von Rissen in der Schiene liegt in der Materialermüdung des Werkstoffes infolge der Betriebsbelastungen im RadSchiene-Kontakt. Nach einer gewissen Beanspruchungsdauer kommt es an den Kontaktflächen der Fahrkante zu einer Kaltverfestigung des Schienenstahls. Durch fortschreitende Verfestigung des kontaktbeanspruchten Oberflächenbereichs der gehärteten Schicht wird der Werkstoff spröde und es bilden sich feine Risse aus. Die Risse wachsen anfangs unter einem flachen Winkel in das Schieneninnere hinein, neigen dann aber ab einem gewissen Stadium dazu in das Innere des Schienenkopfes abzukippen, was im Extremfall zu einem Schienenbruch führen kann. Diese Rollkontaktermüdungsrisse, auch genannt Head Checks, entstehen bevorzugt in der Fahrkante von bogenäußeren Schienen. Die Anwendung der Wirbelstromprüfung an der Schiene wurde bisher zur Ermittlung der Schädigungstiefe dieser Rollkontaktermüdungsrisse eingesetzt. Das Wirbelstromverfahren besitzt die Eigenschaft, sehr empfindlich auf alle Veränderungen der Materialeigenschaften an der Oberfläche zu reagieren. Daher wurde festgestellt, dass sich neben der Detektion von Rissen auch Fehler wie Eindrückungen oder Schlupfwellen, bis hin zu Materialveränderungen durch Schweißen oder Aufhärtungen in der Schienenoberfläche bestimmen lassen. Die Wirbelstromprüfung besitzt daher das Potenzial, mögliche Orte der Entstehung von Ermüdungsrissen in einem extrem frühzeitigen Stadium nachzuweisen. Ziel ist es, die rissgefährdeten Zonen schon im Zustand der Kaltverfestigung zu identifizieren. Dadurch können sich neue Aspekte für die präventive Schieneninstandhaltung ergeben. T2 - DGZfP-Jahrestagung 2010 - Zerstörungsfreie Materialprüfung ZfP in Forschung, Entwicklung und Anwendung CY - Erfurt, Germany DA - 10.05.2010 PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-214813 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-21481 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Goebbels, Jürgen A1 - Meinel, Dietmar A1 - Paetsch, O. A1 - Prohaska, S. A1 - Zobel, Valentin T1 - Comparison of crack detection methods for analyzing damage processes in concrete with computed tomography N2 - Analyzing damages at concrete structures due to physical, chemical, and mechanical exposures need the application of innovative non-destructive testing methods that are able to trace spatial changes of microstructures. Here, the utility of three different crack detection methods for the analysis of computed tomograms of various cementitious building materials is evaluated. Due to the lack of reference samples and standardized image quality evaluation procedures, the results are compared with manually segmented reference data sets. A specific question is how automatic crack detection can be used for the quantitative characterization of damage processes, such as crack length and volume. The crack detection methods have been integrated into a scientific visualization system that allows displaying the tomography images as well as presenting the results. T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Crack detection KW - Computed tomography KW - Data visualization PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243569 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 2) SP - 1 EP - 8 PB - Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24356 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Duffner, Eric A1 - Gregor, Christian A1 - Bohse, Jürgen T1 - Überwachung der Fertigungsqualität von Faserverbund - Druckbehältern mittels Schallemissionsprüfung N2 - Ziel der Untersuchung ist die Validierung einer Prüfmethodik zur Sicherung der Fertigungsqualität von Faserverbund – Druckbehältern unter realen Fertigungsbedingungen. Das Verfahren basiert auf Merkmalen und zulässigen Grenzwerten, die aus Schallemissionsverläufen bei der Erstdruckprüfung abgeleitet werden. Die Methodik konnte zuvor bereits erfolgreich an Faserverbund – Druckbehältern mit metallischem Liner getestet und patentiert werden. Mit den aktuellen Untersuchungen wurde die Möglichkeit des Erkennens von Fertigungsfehlern in Kohlenstofffaser/Glasfaser – Hybriddruckbehältern mit polymerem Liner evaluiert. Dazu wurden Faserverbund – Druckbehälter mittels Schallemissionsmessung bei einer hydraulischen Erstdruckprüfung überwacht, wie sie (ohne Schallemissionsprüfung) generell zur Qualitätssicherung nach der Fertigung von Faserverbund – Druckbehältern gefordert wird. An Druckbehältern aus einer Serienproduktion wurden die Schallemissionsverläufe registriert und die mittleren Merkmalswerte sowie deren Streuung als Referenz ermittelt. Diese werden mit den Schallemissionsverläufen von Druckbehältern mit gezielt eingebrachten Fertigungsfehlern verglichen. Bei den Fertigungsfehlern handelt es sich um Fehler, die in der Serienproduktion auftreten können und mit den Methoden der herkömmlichen Qualitätssicherung schwer oder gar nicht nachzuweisen sind. Alle untersuchten Druckbehälter wurden im Anschluss an die Erstdruckprüfung auf verschiedene Weise bis zum Versagen (Leckage, Bersten) beansprucht. Damit war es möglich, den tatsächlichen Einfluss der Fertigungsfehler auf den Berstdruck bzw. das Ermüdungsverhalten der Behälter zu verifizieren und die Aussagefähigkeit des Schallemissionsverfahrens zu beurteilen. T2 - 18. Kolloquium Schallemission CY - Wetzlar, Germany DA - 27.10.2011 KW - Faserverbund-Druckbehälter KW - Schallemissionsprüfung KW - Fertigungsüberwachung PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-247881 SN - 978-3-940283-37-5 IS - DGZfP-BB 131 (Vortrag 16) SP - 1 EP - 9 AN - OPUS4-24788 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Caldeira, Rui A1 - Bartusch, Jürgen A1 - Kupnik, M. T1 - Air-coupled ultrasonic ferroelectret receiver with additional DC voltage N2 - Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio. T2 - Eurosensors 2017 CY - Paris, France DA - 3.9.2017 KW - Ultrasonic KW - Air-coupled KW - Cellular polypropylene KW - Transducer KW - Ferroelectret PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-419009 DO - https://doi.org/10.3390/proceedings1040362 VL - 1 IS - 4 SP - Article 362, 1 EP - 4 AN - OPUS4-41900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wachsmuth, Janne T1 - Wellenform basierte Quellenlokalisierung im Vergleich zu konventionellen Methoden N2 - Für eine 10 mm dicke Stahlplatte kann ein Bandpass so gesetzt werden, dass alle vorhandenen Wellenmoden mit derselben Schallgeschwindigkeit eintreffen. Anhand von Ortungsabweichungen und Ortungsunsicherheitswerten kann gezeigt werden, dass im Vergleich zu herkömmlichen Methoden der Quellenortung die Ortungsgenauigkeit durch eine Frequenzfilterung verbessert werden kann. T2 - 18. Kolloquium Schallemission CY - Wetzlar, Deutschland DA - 27.10.2011 KW - Schallemissionsprüfung KW - Ermüdungsrisswachstum KW - Korrosion PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246612 SN - 978-3-940283-37-5 SP - 1 EP - 6 PB - DGZfP-BB 131 AN - OPUS4-24661 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Kolkoori, Sanjeevareddy A1 - Bellon, Carsten T1 - Quantitative simulation of back scatter X-ray imaging and comparison to experiments N2 - X-ray backscatter imaging is a well established NDT technique to inspect complex objects using only a single-sided access. In difference to conventional transmission X-ray radiography, the X-ray backscatter imaging utilizes the scattered radiation caused by the Compton scattering effect. In order to achieve high backscatter intensities from a test object, it is necessary to optimize the backscatter system parameters namely the angle between source and slit camera, the slit collimator system, the shielding between source and scatter camera, and the type of detector. In addition, the scatter phenomena in to the investigated object need to be understood. In this contribution, we present a Monte Carlo model McRay which considers all relevant single and multiple interactions of photons and electrons. This model can be used to simulate back scatter techniques. It allows not only calculating the scatter image for a given experimental setup but also registering the spectrum of the detected scattered photons. Both aspects are important to understand the imaging process, to interpret the results, and to optimize the backscatter camera investigated here. Additionally experimental results will be presented and compared with simulations. T2 - 19th World Conference on Nondestructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Radiology KW - Back-scatter techniques KW - Simulation KW - Monte Carlo methods KW - Measurements PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-365897 SN - 978-3-940283-78-8 VL - 158 SP - 1 EP - 11 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung (DGZfP) CY - Berlin, Germany AN - OPUS4-36589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -