TY - GEN A1 - Igartua, A. A1 - Fdez-Pérez, X. A1 - Illarramendi, I. A1 - Luther, R. A1 - Rausch, J. A1 - Woydt, Mathias ED - Carmo, J. P. ED - Ribeiro, J. E. T1 - Biolubricants and triboreactive materials for automotive applications N2 - The text deals with passenger car motor oils (PCMO) with reduced metal-organic additives. KW - Biolubricants KW - Passenger car motor oils (PCMO) KW - Automotive KW - Tribology PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-464317 SN - 978-9-53510-698-2 DO - https://doi.org/10.5772/46852 SP - 119 EP - 146 PB - INTECH CY - Rijeka, Croatia AN - OPUS4-46431 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pelkner, Matthias A1 - Neubauer, Andreas A1 - Reimund, Verena A1 - Kreutzbruck, Marc T1 - Routes for GMR-sensor design in non-destructive testing N2 - GMR sensors are widely used in many industrial segments such as information technology, automotive, automation and production, and safety applications. Each area requires an adaption of the sensor arrangement in terms of size adaption and alignment with respect to the field source involved. This paper deals with an analysis of geometric sensor parameters and the arrangement of GMR sensors providing a design roadmap for non-destructive testing (NDT) applications. For this purpose we use an analytical model simulating the magnetic flux leakage (MFL) distribution of surface breaking defects and investigate the flux leakage signal as a function of various sensor parameters. Our calculations show both the influence of sensor length and height and that when detecting the magnetic flux leakage of µm sized defects a gradiometer base line of 250 µm leads to a signal strength loss of less than 10% in comparison with a magnetometer response. To validate the simulation results we finally performed measurements with a GMR magnetometer sensor on a test plate with artificial µm-range cracks. The differences between simulation and measurement are below 6%. We report on the routes for a GMR gradiometer design as a basis for the fabrication of NDT-adapted sensor arrays. The results are also helpful for the use of GMR in other application when it comes to measure positions, lengths, angles or electrical currents. KW - Giant magneto resistance KW - Non-destructive testing KW - Magnetic flux leakage KW - Sensor array PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-271325 DO - https://doi.org/10.3390/s120912169 SN - 1424-8220 VL - 12 IS - 9 SP - 12169 EP - 12183 PB - MDPI CY - Basel AN - OPUS4-27132 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Poli, Marco A1 - Grätz, Rainer A1 - Schröder, Volkmar T1 - An experimental study on safety-relevant parameters of turbulent gas explosion venting at elevated initial pressure N2 - The effects of a gas explosion in enclosures like vessels can be limited e.g. by gas explosion venting systems. The major design step of this constructive explosion protection method is to determine the required vent area, which depends significantly on whether turbulent combustion exists. However, current standards like NFPA 68 or EN 14994 are applicable only to limited boundary conditions and as far as possible only to laminar flame propagation. Difficulties arise in the assessment or predictability of gas explosion hazard when turbulence occurs. In this research especially venting at elevated initial pressure has been shown to accelerated flame propagations and therefore, to a considerably higher reduced pressure. Therefore, it is essential to provide a broader data base of turbulent combustion and explosion behavior to verify the existing rules or to determine their safety-relevant parameters. For a better safety assessment or design of protective systems the turbulent combustion and accelerated gas explosion behaviour of quiescent methane and hydrogen in air were investigated at initial pressures up to 8 bar using vessels up to 100 litres. In particular a systematic study was performed to investigate the influence of turbulence on the overpressure development during accelerated gas explosion. Moreover, the present study consider the position of the spark igniters, the burning velocity and the maximum pressure rise for different concentration of fuel as well as the size of orifice and/or vent area. A choice of experimental tests showed under the investigated conditions that not only turbulence inducing obstacles but also over sized vent areas could lead to an increased pressure development and therefore to an inacceptable safety state. T2 - 20th International Congress of Chemical and Process Engineering CHISA 2012 CY - Prague, Czech Republic DA - 25.08.2012 KW - Gas explosion venting KW - Turbulent combustion KW - Obstacles PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-264288 DO - https://doi.org/10.1016/j.proeng.2012.07.398 SN - 1877-7058 VL - 42 SP - 90 EP - 99 PB - Elsevier CY - Amsterdam AN - OPUS4-26428 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kind, Thomas T1 - Ortung von Spanngliedern zum schadensfreien Bohren im Rahmen von Ertüchtigungsmaßnahmen N2 - Am Beispiel der Ertüchtigung einer Brücke in Bremen wird gezeigt, wie mit den zerstörungsfreien Prüfverfahren (ZfP) Radar- und Ultraschall die genau Lage vorgespannte Bewehrung gefunden bzw. bestätigt werden kann. Im Rahmen von Ertüchtigungsmaßnahmen an Spannbetonbrücken werden häufig Kernbohrungen durchgeführt, die die vorhandenen Spannbewehrungen nicht beschädigen dürfen. Es wird die Vorgehensweise beschrieben, wie mit ZfP ein wesentlicher Beitrag geleistet wird, das Risiko einer Beschädigung zu minimieren und somit eine bessere Planungssicherheit für die Ertüchtigungsmaßnahmen zu schaffen. Dabei werden auch die Grenzen der beiden Verfahren aufgezeigt. T2 - Fachtagung Bauwerksdiagnose 2012 - Praktische Anwendungen zerstörungsfreier Prüfungen und Zukunftsaufgaben CY - Berlin, Germany DA - 23.02.2012 KW - Radar KW - Zerstörungsfreie Prüfung KW - Stahlbeton KW - Ultraschall PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-398225 SN - 978-3-940283-40-5 VL - 134 (Vortrag 11) SP - 1 EP - 7 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin, Germany AN - OPUS4-39822 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Boehm, Rainer A1 - Brackrock, Daniel A1 - Montag, Hans-Joachim A1 - Brekow, Gerhard T1 - Matrixarrays zur bildgebenden Ultraschallprüfung am Beispiel 6 mm dicker CFK-Platten N2 - Faserverbundwerkstoffe wie kohlefaserverstärkte Kunststoffe CFK sind vergleichsweise schwer mit Ultraschall zu prüfen, weil die starke Dämpfung, der inhomogene Aufbau und die akustische Anisotropie die Wellenausbreitung behindern bzw. komplizieren. Die Folge ist, dass die Ansprüche an die Prüfung oft stark reduziert werden müssen. Die vorgestellte Prüftechnik nutzt die Möglichkeiten der räumlichen Fokussierung und des zweidimensionalen Winkelscans von Matrix Phased Array Prüfköpfen MPA in Kombination mit Echosignalüberlagerungsalgorithmen für eine substantielle Verbesserung der Auflösung und des Signal-Rausch-Verhältnisses. Sowohl bei der Ansteuerung des MPA als auch bei der Auswertung wird die Anisotropie des Werkstoffs berücksichtigt. Das MPA wird über die Oberfläche bewegt und an einer Anzahl von Messpunkten werden zweidimensionale Winkelscans durchgeführt. Das Ergebnis sind räumliche Echohöhenverteilungen, aus denen Schnittbilder oder auch Volumendarstellungen erzeugt werden können. Anhand von Messungen an CFK-Platten mit Flachbodenbohrungen KSR 1 und 2 sollen die Empfindlichkeit und das Auflösungsvermögen der Prüftechnik demonstriert werden. Weiterhin werden Untersuchungen an Impaktschäden gezeigt, die typischerweise bei Faserverbundwerkstoffen bei starken punktförmigen Belastungen auftreten. T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 17.09.2012 KW - Ultraschallprüfung KW - Matrix phased array KW - Bildgebung KW - CFK KW - Anisotropie PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-285729 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-28572 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beckmann, Jörg A1 - Fratzscher, Daniel A1 - von Chrzanowski, Lars A1 - Ewert, Uwe T1 - Zeitaufgelöste THz-Spektroskopie für technische und zivile Sicherheitsanwendungen N2 - Vortrag über Zeitaufgelöste THz-Spektroskopie für technische und zivile Sicherheitsanwendungen T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 17.09.2012 KW - THz Spektroskopie KW - Technische und zivile Sicherheit PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-280013 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - Mi.1.C.4, 1 EP - 14 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-28001 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques N2 - The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions. KW - Toxicity KW - Drug discovery KW - Natural products KW - Environmental analysis KW - Lead identification PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-262960 DO - https://doi.org/10.3390/s120709181 SN - 1424-8220 VL - 12 IS - 7 SP - 9181 EP - 9209 PB - MDPI CY - Basel AN - OPUS4-26296 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Taffe, Alexander A1 - Spies, M. A1 - Recknagel, J. T1 - Schulung zur zuverlässigen Ortung von Bewehrung in Stahlbetonbauteilen von Kraftwerken N2 - In kerntechnischen Anlagen werden Revisionszeiträume genutzt, um unter anderem Anlagenteile nach dem Stand der Technik zu ertüchtigen und um Nachrüstungsmaßnahmen zur Erhöhung der Betriebssicherheit durchzuführen. Solche Anlagenteile werden häufig mittels Dübelplatten befestigt. Die Dübel sind in Stahlbetonbauteile einzubringen, die kraftwerkstypisch mit dichter Bewehrung versehen sind. Zerstörungsfreie Untersuchungen zur genauen Ortung bewehrungsfreier Orte sind hierzu erforderlich. Bei dieser vermeintlich einfachen Prüfaufgabe wurde deutlich, dass in der Praxis Bedarf an verbesserter Anwendungssicherheit der zur Verfügung stehenden ZFP-Verfahren besteht, die eng mit der Ausbildung von Prüfern verbunden ist. Dieser Beitrag berichtet über die bislang im Bereich ZfPBau erstmalig umgesetzte Strategie aus Verfahrensanweisung und Schulung zur zuverlässigen Ortung von Bewehrung an Stahlbetonbauteilen. Sie kann als Muster für weitere ZfPBau-Schulungen zur zuverlässigen Anwendung der Verfahren dienen. T2 - Fachtagung Bauwerksdiagnose 2012 - Praktische Anwendungen zerstörungsfreier Prüfungen und Zukunftsaufgaben CY - Berlin, Germany DA - 23.02.2012 KW - Zerstörungsfreie Prüfung im Bauwesen KW - ZfPBau KW - Ausbildung KW - Bewehrungsortung KW - Bauwerksdiagnose KW - Kernkraftwerk KW - Bauwerksprüfung PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-285909 UR - https://bauwerksdiagnose2012.dgzfp.de/Portals/bwd2012/Dokumente/bb/v04.pdf SN - 978-3-940283-40-5 IS - DGZfP BB 134 SP - 1 EP - 7 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-28590 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Drogan, D. A1 - Sheldrick, A. J. A1 - Schütze, M. A1 - Knüppel, S. A1 - Andersohn, F. A1 - di Giuseppe, R. A1 - Herrmann, Bianca A1 - Willich, S. N. A1 - Garbe, E. A1 - Bergmann, M. M. A1 - Boeing, H. A1 - Weikert, C. T1 - Alcohol consumption, genetic variants in alcohol deydrogenases, and risk of cardiovascular diseases: A prospective study and meta-analysis N2 - Objective: First, to investigate and compare associations between alcohol consumption and variants in alcohol dehydrogenase (ADH) genes with incidence of cardiovascular diseases (CVD) in a large German cohort. Second, to quantitatively summarize available evidence of prospective studies on polymorphisms in ADH1B and ADH1C and CVD-risk. Methods: We conducted a case-cohort study nested within the European Prospective Investigation into Cancer and Nutrition (EPIC)-Potsdam cohort including a randomly drawn subcohort (n = 2175) and incident cases of myocardial infarction (MI; n = 230) or stroke (n = 208). Mean follow-up time was 8.2±2.2 years. The association between alcohol consumption, ADH1B or ADH1C genotypes, and CVD-risk was assessed using Cox proportional hazards regression. Additionally, we report results on associations of variants in ADH1B and ADH1C with ischemic heart disease and stroke in the context of a meta-analysis of previously published prospective studies published up to November 2011. Results: Compared to individuals who drank >0 to 6 g alcohol/d, we observed a reduced risk of MI among females consuming >12 g alcohol/d (HR = 0.31; 95% CI: 0.10–0.97) and among males consuming >24 to 60 g/d (HR = 0.57; 95% CI: 0.33–0.98) or >60 g alcohol/d (HR = 0.30; 95% CI: 0.12–0.78). Stroke risk was not significantly related to alcohol consumption >6 g/d, but we observed an increased risk of stroke in men reporting no alcohol consumption. Individuals with the slowcoding ADH1B*1/1 genotype reported higher median alcohol consumption. Yet, polymorphisms in ADH1B or ADH1C were not significantly associated with risk of CVD in our data and after pooling results of eligible prospective studies [ADH1B*1/1: RR = 1.35 (95% CI: 0.98–1.88; p for heterogeneity: 0.364); ADH1C*2/2: RR = 1.07 (95% CI: 0.90–1.27; p for heterogeneity: 0.098)]. Conclusion: The well described association between alcohol consumption and CVD-risk is not reflected by ADH polymorphisms, which modify the rate of ethanol oxidation. KW - Coronary heart disease KW - Myocardial infarction KW - Dehydrogenase KW - Genotypes KW - Relative validity KW - Drinking habits KW - EPIC-Potsdam Study KW - German part KW - Case cohort KW - Stroke KW - Reproducibility PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-633710 DO - https://doi.org/10.1371/journal.pone.0032176 SN - 1932-6203 N1 - The recruitment phase of the EPIC-Potsdam Study was supported by the Federal Ministry of Science, Germany (01 EA 9401), and the European Union (SOC 95201408 05F02). The follow-up was supported by the German Cancer Aid (70-2488-Ha I) and the European Community (SOC 98200769 05F02). VL - 7 IS - 2 SP - 1 EP - 11 PB - Public Library of Science (PLoS) CY - San Francisco, California, US AN - OPUS4-63371 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Horn, Wolfgang A1 - Farke, M. A1 - Kalus, Sabine A1 - Nohr, Michael A1 - Jann, Oliver T1 - Determination of formic and acetic acid emissions in indoor air or from building products N2 - Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography – mass spectrometry/mass spectrometry). N2 - Viele Konstruktions- und Baumaterialien, wie Holz, Kleber und Anstriche, sind mögliche Quellen für leicht flüchtige organische Verbindungen (VVOC) und flüchtige organische Verbindungen (VOC), wie Ameisen- und Essigsäure. Bedingt durch die hohe Dichtigkeit und den damit verbundenen niedrigen Luftwechsel in neuen Gebäuden können die Konzentrationen dieser gesundheitsgefährdenden Substanzen beträchtlich ansteigen. Um das Risiko zu minimieren, sollen Emissionen aus Bauprodukten identifiziert und quantifiziert werden. Mit der üblichen Standardmethode, die auf einer Luftprobenahme auf Tenax® und anschließender Analyse mittels GC-MS basiert, können diese Säuren nicht ausreichend detektiert werden. Ziel dieser Arbeit ist der Vergleich von zwei unterschiedlichen Methoden zur Bestimmung von Essig- und Ameisensäure. Die Luftprobenahme der ersten Methode, die üblicherweise zur Identifizierung und Quantifizierung von VOC genutzt wird, wurde gemäß ISO 16000-6 and ISO 16017-1 auf Carbotrap® 202, ein mit mehreren Adsorbentien gepacktes Thermodesorptionsrohr, mit anschließender Identifikation und Quantifizierung mittels GC-MS durchgeführt. Die zweite Methode basiert auf einer Luftprobenahme mittels 2,4-Dinitrophenylhydrazin-(DNPH)-Kartuschen, Derivatisierung, Elution, Identifikation und Quantifizierung der Derivate mit LC-MS/MS (Flüssigkeitschromatographie – Massenspektometrie/Massenspektometrie). KW - Formic acid KW - Acetic acid KW - VVOCs KW - Air sampling KW - DNPH PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-255911 UR - http://www.gefahrstoffe.de/gest/article.php?data[article_id]=65887 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 72 IS - 3 SP - 84 EP - 88 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-25591 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pelkner, Matthias A1 - Neubauer, Andreas A1 - Reimund, Verena A1 - Erthner, Thomas A1 - Panke, Nicolai A1 - Kreutzbruck, Marc T1 - Automatisierte Streuflussprüfung und Bewertung von Zylilnderlagerringen unter Anwendung von GMR-Sensorarrays N2 - Dieser Beitrag behandelt die automatisierte Streuflussprüfung an Zylinderlagerschalen. Die Anforderung an das im Verbundprojekt mit Industriepartnern aufgebaute System waren neben einer schnellen Detektion von Mikrorissen die Bewertung und grafische Darstellung der ermittelten Risssignale. Mithilfe neu angepasster GMR-Sensorarrays war es möglich, die Prüfung der Außen-, Innen- und Stirnflächen in kürzester Zeit (< 2 min) durchzuführen und Risse mit einer Tiefe unterhalb der geforderten 50 µm zu detektieren (Risse mit Tiefen von 30 µm konnten noch mit einem guten Signal-Rausch-Abstand besser 6 dB detektiert werden). Eine selbst entwickelte Messsoftware bereitet die Daten auf und stellt sie grafisch dar. Zusätzlich werden die Mikrorisse bewertet. T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 17.09.2012 KW - Streufluss KW - GMR KW - Sensorarrays PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-279490 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - Mo.2.A.2, 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-27949 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Sabine A1 - Niederleithinger, Ernst A1 - Bohlen, T. T1 - Reverse time migration: a seismic imaging technique applied to synthetic ultrasonic data N2 - Ultrasonic echo testing is a more and more frequently used technique in civil engineering to investigate concrete building elements, to measure thickness as well as to locate and characterise built-in components or inhomogeneities. Currently the Synthetic Aperture Focusing Technique (SAFT), which is closely related to Kirchhoff migration, is used in most cases for imaging. However, this method is known to have difficulties to image steeply dipping interfaces as well as lower boundaries of tubes, voids or similar objects. We have transferred a processing technique from geophysics, the Reverse Time Migration (RTM) method, to improve the imaging of complicated geometries. By using the information from wide angle reflections as well as from multiple events there are fewer limitations compared to SAFT. As a drawback the required computing power is significantly higher compared to the techniques currently used. Synthetic experiments have been performed on polyamide and concrete specimens to show the improvements compared to SAFT. We have been able to image vertical interfaces of step-like structures as well as the lower boundaries of circular objects. It has been shown that RTM is a step forward for ultrasonic testing in civil engineering. KW - Beton KW - Ultraschall KW - Concrete KW - Imaging KW - Ultrasonics KW - Reverse time migration PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-262952 DO - https://doi.org/10.1155/2012/128465 SN - 1687-8868 SN - 1687-885X VL - 2012 IS - Article ID 128465 SP - 1 EP - 7 PB - Hindawi Publishing Corporation CY - New York, NY, USA AN - OPUS4-26295 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Numerische Korrektur des Hinterleuchtens von Röntgendetektoren N2 - Eine neuartige Korrektur artefaktisch gemessener Intensitäten von Röntgenflachdetektoren wird vorgeschlagen. Die betrachteten Artefakte betreffen eine diffuse Umverteilung der Intensität und führen zu beträchtlichen Verfälschungen der wahren Schwächung und verletzen mithin das Lambert-Beer'sche Gesetz. Sie werden sowohl in Laborexperimenten mit Röntgenröhren (polychromatische Einstrahlung) als auch mit monochromatischer Synchrotronstrahlung bei Einsatz indirekt konvertierender Detektionssysteme (Fluoreszenzschirm, Optik, CCD-Chip) beobachtet. Dieser Effekt wird als Hinterleuchten bezeichnet. In der vorgestellten Studie werden mittels wohldefinierter Randbedingungen Gesetzmäßigkeiten des Hinterleuchtens untersucht: durch Einsatz monochromatischer Strahlung können Aufhärtungseffekte als Ursache ausgeschlossen werden. Das Hinterleuchten ist umso stärker ausgeprägt, je weniger Detektorfläche vom Objekt abdeckt wird und je stärker das Objekt schwächt. Mit Blick auf Tomographien ergibt sich eine Modulation der 'Dichte' als Funktion des Projektionswinkels, deren Amplitude mit dem Objektumfang steigt (Dynamik). Der isotrope und homogene Ansatz zur numerischen Korrektur macht lediglich Gebrauch von Intensitätsmittelwerten und stellt die Gültigkeit des Schwächungsgesetzes in modifizierter Form wieder her. T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 17.09.2012 KW - Röntgendetektor KW - Hinterleuchten PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-277372 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - P 13 / Mo.4.B, 1 EP - 7 AN - OPUS4-27737 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -