TY - JOUR A1 - Färber, C. A1 - Titschack, J. A1 - Schönberg, Chr. H. L. A1 - Ehrig, Karsten A1 - Boos, K. A1 - Illerhaus, Bernhard A1 - Asgaard, U. A1 - Bromley, R. G. A1 - Freiwald, A. A1 - Wisshak, M. ED - Bahn, M. ED - Fennel, K. ED - Kesselmeier, J. ED - Naqvi, S. W. A. T1 - Long-term macrobioerosion in the Mediterranean Sea assessed by micro-computed tomography N2 - Biological erosion is a key process for the recycling of carbonate and the formation of calcareous sediments in the oceans. Experimental studies showed that bioerosion is subject to distinct temporal variability, but previous long-term studies were restricted to tropical waters. Here, we present results from a 14-year bioerosion experiment that was carried out along the rocky limestone coast of the island of Rhodes, Greece, in the Eastern Mediterranean Sea, in order to monitor the pace at which bioerosion affects carbonate substrate and the sequence of colonisation by bioeroding organisms. Internal macrobioerosion was visualised and quantified by micro-computed tomography and computer-algorithm-based segmentation procedures. Analysis of internal macrobioerosion traces revealed a dominance of bioeroding sponges producing eight types of characteristic Entobia cavity networks, which were matched to five different clionaid sponges by spicule identification in extracted tissue. The morphology of the entobians strongly varied depending on the species of the producing sponge, its ontogenetic stage, available space, and competition by other bioeroders. An early community developed during the first 5 years of exposure with initially very low macrobioerosion rates and was followed by an intermediate stage when sponges formed large and more diverse entobians and bioerosion rates in-creased. After 14 years, 30 % of the block volumes were occupied by boring sponges, yielding maximum bioerosion rates of 900 g m. KW - Bioerosion KW - Computed tomography KW - Carbonate substrate PY - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-372709 UR - http://www.biogeosciences.net/13/3461/2016/bg-13-3461-2016.pdf VL - 13 IS - 11 SP - 3461 EP - 3474 PB - Copernicus Publications CY - Göttingen AN - OPUS4-37270 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas T1 - Combining analytical and Monte Carlo modelling for industrial radiology N2 - Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we Focus on Monte Carlo Simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications. T2 - 19th Wolrd Conference on Nondestructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Radiography KW - Computed tomography KW - Simulation KW - Monte Carlo methods PY - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-365856 SN - 978-3-940283-78-8 VL - 158 SP - 1 EP - 9 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung (DGZfP) CY - Berlin, Germany AN - OPUS4-36585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Maenz, S. A1 - Bischoff, S. A1 - Bungartz, M. A1 - Bossert, J. A1 - Kunisch, E. A1 - Kinne, R. ED - Maenz, S. T1 - Micro computer tomography (μCT) set-up for long-term serial measurements, image evaluation, and subsequent compressive strength tests on frozen sheep vertebrae for osteoporosis research N2 - Injection of poly(methyl methacrylate) cements, one standard Treatment for osteoporotic vertebral body fractures, may lead to critical loads and subsequent fractures in adjacent vertebral bodies. Biodegradable calcium phosphate cements (CPC) with bioinductive growth factors may be an alternative, since they have a Young’s modulus comparable to that of cancellous bone. Non-destructive tests with μCT and quantitative Image evaluation are used to assess new bone growth and material resorption following intravertebral injection of CPC. Immediate deep-freezing of excised bone prevents shrinkage or tissue disintegration and the samples have to be kept frozen for all following steps, including transport, μCT measurements, and subsequent biomechanical tests. Here we will report on a set-up to preserve the frozen state of the material and allow stable long-term serial μCT measurements. In addition, the image processing technique for the evaluation of bone growth and selected results on subsequently carried out compressive strength tests will be presented. T2 - WCNDT2016 CY - München, Germany DA - 13.6.2016 KW - Computed tomography KW - Osteoporosis KW - CT PY - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-366410 UR - https://www.ndt.net/?id=19382 VL - BB 158 SP - 1 EP - 7 PB - DGZfP CY - Berlin AN - OPUS4-36641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Laquai, René A1 - Schaupp, Thomas A1 - Müller, Bernd R. A1 - Griesche, Axel A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Kannengießer, Thomas A1 - Bruno, Giovanni T1 - 3D Crack analysis in hydrogen charged lean duplex stainless steel with synchrotron refraction CT N2 - Hydrogen in metals can cause a degradation of the mechanical properties, the so-called hydrogen embrittlement. In combination with internal stresses, hydrogen assisted cracking (HAC) can occur. This phenomenon is not completely understood yet. To better characterise the cracking behaviour, it is important to gain information about the evolution of the 3D crack network. For this purpose samples of lean duplex stainless steel were loaded with hydrogen by means of electrochemical charging and investigated by means of synchrotron refraction CT and SEM fractography after uniaxial tensile loading. Synchrotron refraction CT is an analyser-based imaging (ABI) technique. It uses a Si (111) single crystal as analyser, which is placed into the beam path between sample and detector. According to Bragg’s law only incident x-rays within a narrow range around the Bragg-angle are diffracted from the analyser into the detector. Hence, the analyser acts as an angular filter for the transmitted beam. This filtering allows to turn the refraction and scattering of x-rays into image contrast. Refraction occurs at all interfaces, where the density of the material changes and is more sensitive to density changes than the attenuation. Therefore, it is possible to detect smaller cracks than with classical x-ray imaging techniques, like CT, with comparable spacial resolution. It also visualises the 3D structure of the cracks and gains quantitative information about their morphology and distribution. Since cracks introduced by HAC are usually very small and have a small opening displacement, synchrotron refraction CT is expected to be well suited for imaging this cracking mechanism and can be a valuable tool to characterise the formation and the evolution of a 3D crack network. T2 - WCNDT 2016 CY - München, Germany DA - 13.06.2016 KW - X-ray refraction KW - Computed tomography KW - Hydrogen assisted cracking KW - Duplex stainless steel PY - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-366481 SN - 978-3-940283-78-8 VL - BB 158 SP - Tu.4.B.3, 1 EP - 9 AN - OPUS4-36648 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -