TY - JOUR A1 - Zhang, T. A1 - Sens-Schönfelder, C. A1 - Epple, Niklas A1 - Niederleithinger, Ernst T1 - Imaging of Small-Scale Heterogeneity and Absorption Using Adjoint Envelope Tomography: Results From Laboratory Experiments N2 - To complement the information provided by deterministic seismic imaging at length scales above a certain resolution limit we present the first application of adjoint envelope tomography (AET) to experimental data. AET uses the full envelopes of seismic records including scattered coda waves to obtain information about the distribution of absorption and small-scale heterogeneity which provide complementary information about the investigated medium. Being below the resolution limit this small-scale structure cannot be resolved by conventional tomography but still affects wave propagation by attenuating ballistic waves and generating scattered waves. Using ultrasound data from embedded sensors in a meter-sized concrete specimen we image the distribution of absorption and heterogeneity expressed by the intrinsic quality factor Q−1 and the fluctuation strength ɛ that characterizes the strength of the heterogeneity. The forward problem is solved by modeling the 2-D multiple nonisotropic scattering in an acoustic medium with spatially variable heterogeneity and attenuation using the Monte-Carlo method. Gradients for the model updates are obtained by convolution with the back-propagated envelope misfit using the adjoint formalism in analogy to full waveform inversion. We use a late coda time window to invert for absorption and an earlier time window to infer the distribution of heterogeneity. The results successfully locate an area of salt oncrete with increased scattering and concentric anomalies of intrinsic attenuation. The resolution test shows that the recovered anomalies constitute reasonable representations of internal structure of the specimen. KW - Ultrasound KW - Scattering KW - Tomography KW - Concrete KW - Heterogeneity PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-563163 DO - https://doi.org/10.1029/2022JB024972 SN - 2169-9313 VL - 127 IS - 11 SP - 1 EP - 21 PB - American Geophysical Union AN - OPUS4-56316 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schumacher, T. A1 - Bertola, N. A1 - Epple, Niklas A1 - Bruehwiler, E. A1 - Niederleithinger, Ernst T1 - Combined Passive and Active Ultrasonic Stress Wave Monitoring of Concrete Structures: An Overview of Data Analysis Techniques and Their Applications and Limitations N2 - Combined passive ultrasonic (US) stress wave [better known as acoustic emission (AE)] and active US stress wave monitoring has been shown to provide a more holistic picture of ongoing fracture processes, damage progression, as well as slowly occurring aging and degradation mechanisms in concrete structures. Traditionally, different data analysis techniques have been used to analyze the data generated from these two monitoring techniques. For passive US stress wave monitoring, waveform amplitudes, hit rates, source localization, and b-value analysis, among others, have been used to detect and locate cracking. On the other hand, amplitude tracking, magnitude squared coherence (MSC), and coda wave interferometry (CWI) are examples of analyses that have been employed for active US stress wave monitoring. In this paper, we explore some of these data analysis techniques and show where their respective applications and limitations might be. After providing an overview of the monitoring approach and the different data analysis techniques, results and observations from selected laboratory experiments are discussed. Finally, suggestions for further work are proposed. T2 - 11th European Workshop on Structural Health Monitoring (EWSHM 2024) CY - Potsdam, Germany DA - 11.06.2024 KW - Ultrasound KW - Acoustic emission KW - Concrete KW - Stress PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-604687 UR - https://www.ndt.net/article/ewshm2024/papers/824_manuscript.pdf DO - https://doi.org/10.58286/29863 SN - 1435-4934 SP - 1 EP - 8 PB - NDT.net AN - OPUS4-60468 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jägle, Eva A1 - Tuladhar, Rujika A1 - Niederleithinger, Ernst A1 - Epple, Niklas A1 - Sanchez Trujillo, Camila Andrea A1 - Gehlen, Christoph A1 - Timothy, Jithender J. T1 - Evaluation of ultrasonic signals collected from laboratory concrete specimens: Preprocessing and analysis with coda wave interferometry N2 - Efficient maintenance of infrastructure relies on monitoring and assessment of its condition. New technologies and methods thereby enable a deeper understanding of the materials used and of the structures built. Coda Wave Interferometry (CWI) is currently explored for continuous monitoring of reinforced concrete structures as well as material testing. This ultrasound-based method is sensitive to even small material alterations and therefore suitable for the detection of initial damage stages. Herein, a step-by-step procedure for the evaluation of ultrasonic signals with CWI methods is presented. The described procedure is proposed for ultrasonic signals collected with embedded ultrasonic transducers with a center frequency of 50 kHz to 70 kHz from prism-shaped concrete specimen with dimensions of 400 mm x 100 mm x 100 mm. The raw ultrasonic signal, preprocessing and CWI analysis are described and influences of parameters within the analysis are discussed. The presented procedure allows systematic and comparable analysis of ultrasonic signals generated with similar conditions and therefore contributes to the application of CWI methods for structural health monitoring and material testing. KW - Ultrasound KW - Concrete KW - Coda wave interferometry KW - Structural health monitoring PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-656027 DO - https://doi.org/10.1016/j.mex.2026.103811 SN - 2215-0161 VL - 16 SP - 1 EP - 19 PB - Elsevier B.V. AN - OPUS4-65602 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fontoura Barroso, Daniel A1 - Epple, Niklas A1 - Niederleithinger, Ernst T1 - A Portable Low-Cost Ultrasound Measurement Device for Concrete Monitoring N2 - This paper describes a new ultrasonic measuring device called “W-Box”. It was developed based on the requirements of the DFG Forschergruppe (research unit) CoDA for a portable device for monitoring of concrete specimens, models and actual structures using embedded ultrasonic transducers as well as temperature and humidity sensors. The W-Box can send ultrasonic pulses with a variable frequency of 50–100 kHz to one selectable transducer and records signals from up to 75 multiplexed channels with a sample rate of 1 MHz and a resolution of 14 bits. In addition, it measures temperature and humidity with high accuracy, adjustable amplification, restarts automatically after a power failure and can be fully controlled remotely. The measured data are automatically stored locally on-site data quality checks and transferred to remote servers. The comparison of the W-Box with a laboratory setup using commercial devices proves that it is equally reliable and precise, at much lower cost. The W-Box also shows that their measurement capacities, with the used embedded ultrasonic transducers, can reach above 6 m in concrete. KW - Low-cost KW - Coda wave interferometry KW - Ultrasound KW - IoT KW - Non-destructive testing PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-546756 DO - https://doi.org/10.3390/inventions6020036 SN - 2411-5134 VL - 6 IS - 2 SP - 1 EP - 17 PB - MDPI CY - Basel, Switzerland AN - OPUS4-54675 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Epple, Niklas A1 - Schumacher, Thomas A1 - Murtuz, A. K. M. Golam A1 - Niederleithinger, Ernst A1 - Dusicka, Peter T1 - Combined passive and active ultrasonic stress wave monitoring of a full‑scale laboratory reinforced concrete bridge column subject to reverse‑cyclic lateral loading N2 - Effective monitoring of reinforced concrete structures requires techniques that detect early-stage material change and active, localized cracking. This study investigates a combined structural health monitoring approach using passive acoustic emission and active ultrasonic methods on a full-scale reinforced concrete bridge column subjected to reverse-cyclic lateral loading. Active monitoring, based on coda wave interferometry, was used to track changes in wave velocity and waveforms, while passive acoustic emission monitoring was used to detect crack activity. The instrumentation consisted of three embedded ultrasonic transducers and three surface-mounted acoustic emission sensors. The results show that active ultrasonic monitoring is most effective prior to visual damage, successfully detecting the onset of internal cracking via wave velocity decreases exceeding 0.4%, and distinguishing load-induced effects from permanent damage. However, its utility diminished in later stages of damage progression, as strong signal decorrelation hindered further data interpretation. Additionally, active US measurements allowed a comparison of damage severity in different parts of the column. Conversely, passive acoustic emission monitoring effectively tracked the formation of concrete cracks throughout the experiment, with distinct event clusters and high-amplitude signals (> 60 dB) confirming ongoing fracture processes in all damage states. This study confirms that combining these methods results in a more robust structural health monitoring strategy by leveraging their complementary strengths. Active techniques excel at tracking continuous material changes in early damage states, while passive methods are superior for detecting discrete cracking events as damage progresses. Importantly, both methods can utilize the same measurement equipment, enabling a cost-effective approach to continuous damage tracking. KW - Coda wave interferometry KW - Active ultrasonic monitoring KW - Acoustic emission KW - Structural health monitoring KW - Nondestructive evaluation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-638689 DO - https://doi.org/10.1007/s13349-025-00996-w SN - 2190-5479 SP - 1 EP - 24 PB - Springer Nature AN - OPUS4-63868 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas A1 - Sanchez Trujillo, Camila A1 - Fontoura Barroso, Daniel A1 - Hau, Julia A1 - Niederleithinger, Ernst ED - Lienhart, Werner ED - Krüger, Markus T1 - Monitoring of Concrete Infrastructure with Active Ultrasound Coda Wave Interferometry N2 - Coda Wave Interferometry has been used in Geophysics to detect weak changes in scattering media. Past research in Structural Health Monitoring has shown that this methodology can be applied to concrete structures to detect material changes by calculation of relative velocity changes. Successive measurements with embedded ultrasonic transducers provide a repeatable signal for reliable long-term monitoring of concrete. To research the application in real-world structures, we have embedded ultrasonic transducers in a bridge in Ulm and a Metro station in Munich, Germany. This study gives an overview of the monitoring of these two structures. The results show the potential and challenges of the method. Data evaluation can be largely automated to gain insights into material changes and other influences on the structure, such as traffic-induced load and temperature variations. The experiments demonstrate the ease of installation, longevity of the sensor installation, and sensitivity of the measurement technique, but highlight problems with the application, especially if electromagnetic noise affects data quality. As no confirmed substantial damage was recorded during the monitoring period on both structures, we evaluate load tests to investigate the effect of static load on the structures and the coda monitoring results. The experiments show that the influence of load can be detected, even if the temperature influence is not removed from the data. This indicates that online damage detection with coda monitoring is possible, but further research on damage detection in real-world structures has to be conducted to confirm laboratory findings. T2 - 13th International Conference on Structural Health Monitoring of Intelligent Infrastructure CY - Graz, Austria DA - 01.09.2025 KW - Active Ultrasound Measurements KW - Coda Wave Monitoring KW - Embedded Transducers PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640582 DO - https://doi.org/10.3217/978-3-99161-057-1-012 SP - 45 EP - 51 PB - Technische Universität Graz CY - Graz AN - OPUS4-64058 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas A1 - Sanchez Trujillo, Camila Andrea A1 - Hau, Julia A1 - Niederleithinger, Ernst A1 - Malm, F. T1 - Structural Monitoring in an Urban Underground Metro Station Using Cod N2 - Active ultrasonic monitoring with coda wave interferometry has demonstrated its potential for structural Health monitoring in concrete structures. This study investigates its application using ultrasonic transducers embedded in the ceiling of a subway station in Munich, Germany. We evaluate the impact of environmental conditions, specifically electromagnetic interference and temperature, on data quality, as well as the influence of regular loading from passing trams. Results indicate that electromagnetic interference significantly affects measurements, while temperature effects remain minimal due to the station’s stable thermal environment. Long-term measurements and a controlled load test show that both dynamic and static loading from trams induce ultrasonic velocity changes of only 0.01%–0.06%. Although the experiment demonstrates the capacity to detect structural responses and supports the feasibility of long-term monitoring, improved electromagnetic shielding and Hardware reliability are required for successful future applications. T2 - NDT-CE 2025 CY - Izmir, Turkey DA - 24.09.2025 KW - Coda Wave Interferometry (CWI) KW - Structural health monitoring (SHM) KW - Concrete KW - Ultrasonic testing KW - Urban infrastructure PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654619 DO - https://doi.org/10.58286/31706 SN - 1435-4934 SP - 1 EP - 10 PB - e-Journal of Nondestructive Testing (eJNDT) AN - OPUS4-65461 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas A1 - Niederleithinger, Ernst A1 - Fontoura Barroso, Daniel T1 - Coda Wave Interferometry for Monitoring Bridges with Embedded Ultrasonic Transducers – Lessons Learned at the Gänstorbrücke Bridge Ulm, Germany N2 - Ultrasonic Coda Wave interferometry has the potential to detect minute changes in scattering materials like concrete. By permanently installing ultrasonic transducers in concrete, DFG Research unit CoDA aims to develop methods for concrete damage assessment in Germany's aging infrastructure. To test the methods developed in simulations and laboratory experiments on a large scale, we have implemented several ultrasonic transducers at the Gänstorbrücke Ulm, one of Germany's most monitored road bridges. Since fall 2020 we are monitoring parts of the center of the Bridge, as well as an abutment, and compare the results to the commercial monitoring system. All data is recorded with a self-made data collection device, the so-called W-Box, and analyzed with different coda wave-based algorithms to detect signal and volumetric velocity changes. The long-term measurements show that the influence of temperature changes on strains and therefore ultrasound velocity changes calculated with coda waves can be monitored. The capabilities and limitations of the coda wave-based monitoring system are tested in a controlled experiment. Static loading using a truck with varying loads at several positions allows the calibration of the system to improve the detectability of possibly damaging loads and changes induced by this loading. A map of velocity change analyzing data from this load experiment shows that the influence of load on the material and strain distribution can be detected with array measurements. T2 - NDT-CE 2022 - The International Symposium on Nondestructive Testing in Civil Engineering CY - Zurich, Switzerland DA - 16.08.2022 KW - Coda Wave Interferometry KW - Ultrasound KW - Embedded sensors KW - Bridge Monitoring KW - Load Experiment PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-564531 SP - 1 EP - 8 AN - OPUS4-56453 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Diewald, F. A1 - Epple, Niklas A1 - Kraenkel, T. A1 - Gehlen, C. A1 - Niederleithinger, Ernst T1 - Impact of External Mechanical Loads on Coda Waves in Concrete N2 - During their life span, concrete structures interact with many kinds of external mechanical loads. Most of these loads are considered in advance and result in reversible deformations. Nevertheless, some of the loads cause irreversible, sometimes unnoticed changes below the macroscopic scale depending on the type and dimension of the impact. As the functionality of concrete structures is often relevant to safety and society, their condition must be known and, therefore, assessed on a regular basis. Out of the spectrum of non-destructive monitoring methods, Coda Wave Interferometry using embedded ultrasonic sensors is one particularly sensitive technique to evaluate changes to heterogeneous media. However, there are various influences on Coda waves in concrete, and the interpretation of their superimposed effect is ambiguous. In this study, we quantify the relations of uniaxial compression and uniaxial tension on Coda waves propagating in normal concrete. We found that both the signal correlation of ultrasonic signals as well as their velocity variation directly reflect the stress change in concrete structures in a laboratory environment. For the linear elastic range up to 30% of the strength, we calculated a velocity variation of −0.97‰/MPa for compression and 0.33%/MPa for tension using linear regression. In addition, these parameters revealed even weak irreversible changes after removal of the load. Furthermore, we show the time-dependent effects of shrinkage and creep on Coda waves by providing the development of the signal parameters over time during half a year together with creep recovery. Our observations showed that time-dependent material changes must be taken into account for any comparison of ultrasonic signals that are far apart in time. The study’s results demonstrate how Coda Wave Interferometry is capable of monitoring stress changes and detecting even small-size microstructural changes. By indicating the stated relations and their separation from further impacts, e.g., temperature and moisture, we anticipate our study to contribute to the qualification of Coda Wave Interferometry for its application as an early-warning system for concrete structures. KW - Ultrasound KW - Coda Wave Interferometry (CWI) KW - Mechanical Load KW - Microstructure KW - Concrete PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-556878 DO - https://doi.org/10.3390/ma15165482 SN - 1996-1944 VL - 15 IS - 16 SP - 1 EP - 15 PB - MDPI AN - OPUS4-55687 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Clauß, F. A1 - Epple, Niklas A1 - Ahrens, M. A. A1 - Niederleithinger, Ernst A1 - Mark, P. T1 - Correlation of Load-Bearing Behavior of Reinforced Concrete Members and Velocity Changes of Coda Waves N2 - The integral collection of information such as strains, cracks, or temperatures by ultrasound offers the best prerequisites to monitor structures during their lifetime. In this paper, a novel approach is proposed which uses the collected information in the coda of ultrasonic signals to infer the condition of a structure. This approach is derived from component tests on a reinforced concrete beam subjected to four-point bending in the lab at Ruhr University Bochum. In addition to ultrasonic measurements, strain of the reinforcement is measured with fiber optic sensors. Approached by the methods of moment-curvature relations, the steel strains serve as a reference for velocity changes of the coda waves. In particular, a correlation between the relative velocity change and the average steel strain in the reinforcement is derived that covers 90% of the total bearing capacity. The purely empirical model yields a linear function with a high level of accuracy (R 2 =0.99, R2=0.99, RMSE≈90μ RMSE≈90μ strain). KW - Ultrasound KW - Coda Wave Interferometry (CWI) KW - Structural Health Monitoring KW - Reinforced Concrete KW - Embedded Sensors PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-542316 DO - https://doi.org/10.3390/ma15030738 VL - 15 IS - 3 SP - 738 PB - MDPI AN - OPUS4-54231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -