TY - JOUR A1 - Smerechuk, Anastasiia A1 - Guilherme Buzanich, Ana A1 - Büchner, Bernd A1 - Wurmehl, Sabine A1 - Morrow, Ryan T1 - Synthesis and properties of Sr2La2NiW2O12, a new S = 1 triangular lattice magnet N2 - Magnetic materials featuring triangular arrangements of spins are frequently investigated as platforms hosting magnetic frustration. Hexagonal perovskites with ordered vacancies serve as excellent candidates for two-dimensional triangular magnetism due to the considerable separation of the magnetic planes. In this work, the effects of chemical pressure on the ferromagnetic ground state of Ba2La2NiW2O12 by substitution of Ba2+ with Sr2+ to produce Sr2La2NiW2O12 are investigated. The two materials are characterized using synchrotron-based XRD, XANES and EXAFS in addition to magnetometry in order to correlate their crystal structures and magnetic properties. Both materials form in space group R 3, yet as a result of the enhanced bending of key bond angles due to the effects of chemical pressure, the T C value of the magnetic Ni2+ sublattice is reduced from ∼6 K in Ba2La2NiW2O12 to 4 K in Sr2La2NiW2O12. KW - XRD KW - Magnetic materials KW - EXAFS PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652982 DO - https://doi.org/10.1107/S2052520624007091 SN - 2052-5206 VL - 80 IS - 5 SP - 467 EP - 473 PB - International Union of Crystallography (IUCr) AN - OPUS4-65298 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wosniok, Aleksander A1 - Schukar, Marcus A1 - Breithaupt, Mathias A1 - Kriegsmann, Andreas T1 - Distributed Fibre Optic Monitoring of Hydrogen Storage Composite Pressure Vessels for Automotive Use N2 - We present our research work on the condition monitoring of hydrogen storage composite pressure vessels using distributed fibre optic sensors. The sensing fibres are integrated into the composite structure by wrapping them over the polymer liner in the helical and circumferential direction during the manufacturing process of the carbon fibre reinforced polymer. The following use of optical backscatter reflectometry allows for continuous condition monitoring and precise detection and localization of structural damages during the entire service life. To account for the time-dependent strength degradation of the composite pressure vessels, both slow burst and ambient hydraulic cycling tests, respectively, were conducted on five 70 MPa pressure vessels with integrated fibre optic sensors. The results achieved via distributed fibre optic strain sensing demonstrate a near linear strain response to pressure suitable for sensitive condition monitoring and confirm the required robustness of the selected sensor solution. T2 - DGZfP-Jahrestagung 2025 CY - Berlin, Germany DA - 26.05.2025 KW - Distributed fibre optic sensor (DFOS) KW - Composite pressure vessel KW - Optical backscatter reflectometry KW - Slow burst test KW - Ambient hydraulic cycling test PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653067 DO - https://doi.org/10.58286/32344 SP - 1 EP - 8 PB - NDT.net AN - OPUS4-65306 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stohl, Leonie A1 - Manninger, Tanja A1 - Dehn, Frank A1 - von Werder, Julia T1 - Understanding bioreceptivity of concrete: material design and characterization N2 - The climate crisis is driving an increasing demand for ecologically oriented concepts. In the building sector, this demand includes not only the use of environmentally friendly materials but also the greening of urban areas. One promising approach is the development of bioreceptive concrete façades, which support the growth of green biofilms directly on their surfaces. These innovative façades are anticipated to deliver benefits comparable to those of macroscopically greened façades, such as enhanced biodiversity and improved air quality, while offering the advantages of being more self-sustaining and stable systems once fully established. However, the development of bioreceptive concrete presents substantial challenges. Due to the interdisciplinarity and novelty of this field, standardized methods for material characterization and bioreceptivity assessment are currently lacking. This study proposes an approach for evaluating surface properties crucial for bioreceptivity, developed on differently structured samples of ultra-high-performance concrete (UHPC). Existing methods and standards from concrete technology are critically reviewed and, where necessary, modified to meet the unique requirements of measuring bioreceptive material properties. Special attention is given to the surface pH value and water retention characteristics, as these are essential for promoting microbial growth and ensuring the long-term stability of green biofilms. The observed surface characteristics vary according to the imprinted surface structures, offering a spectrum of material properties and enabling the evaluation of their impact on bioreceptivity. The findings presented form the foundation for subsequent laboratory weathering experiments, which will be discussed in a complementary publication. KW - Bioreceptivity KW - Concrete KW - Biofilm PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-648180 DO - https://doi.org/10.1617/s11527-025-02863-y SN - 1359-5997 VL - 58 IS - 10 SP - 1 EP - 12 PB - Springer Science and Business Media LLC AN - OPUS4-64818 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Casperson, Ralf A1 - Heideklang, René A1 - Myrach, Philipp A1 - Onel, Yener A1 - Pelkner, Matthias A1 - Pohl, Rainer A1 - Stegemann, Robert A1 - Ziegler, Mathias A1 - Kreutzbruck, Marc T1 - Vergleich konventioneller und neuer Oberflächenprüfverfahren für ferromagnetische Werkstoffe N2 - Sicherheitsrelevante und zyklisch hoch belastete Bauteile erfordern zur Vermeidung von kostenintensiven Ausfällen besonders stabile Prozessparameter. Bereits sehr kleine Randzonenfehler können unter zyklischer Bauteilbelastung zu Risswachstum und letztendlich zum Bauteilversagen führen. Die frühzeitige Erkennung von Randzonenfehler in Hochleistungsbauteilen wie z.B. Zahnräder, Ritzelwellen und Kurbelwellen erfordert daher eine leistungsfähige zerstörungsfreie Oberflächenrissprüfung, die es ermöglicht in den hochbeanspruchten Funktionsflächen auch Härterisse, Schleifrisse oder Zundereinschlüsse zu detektieren. Hierzu sind in den letzten Jahren einige neue, innovative Oberflächenprüfverfahren wie die laserangeregte Thermografie und die Streuflussprüfung mit hochauflösenden GMR-Sensoren oder magnetooptischen Verfahren entwickelt worden. Zusätzlich zur hohen Empfindlichkeit zeichnen sich diese innovativen Verfahren durch einen schnellen und teils auch berührungslosen Einsatz aus. Da die noch relativ neu-en Verfahren naturgemäß noch nicht normativ verankert sind, wurden auch bereits erste Validierungen durchgeführt. Um die Leistungsfähigkeit der Verfahren eingehend zu untersuchen, erfolgten Testreihen an verschiedenen Testkörpern in Bezug auf Ortsauflösung, Empfindlichkeit, Automatisierung und Bewertung der Messsig-nale. Neben den neuen Verfahren und ihren ersten Schritten hin zur Validierung kamen als Referenz auch die „klassischen“ Verfahren der Magnetpulver- und Wirbelstromprüfung zum Einsatz, deren Leistungsfähigkeit durch angepasste Sondenentwicklung auch für sehr kleine Oberflächendefekte nochmals unter Beweis gestellt wurde. Zusätzlich wurde an einigen Testkörpern eine hochauflösende CT durchgeführt. Die Ergebnisse dieses Vergleiches werden vorgestellt und Möglichkeiten sowie Grenzen der einzelnen Verfahren herausgearbeitet. T2 - DACH-Jahrestagung 2015 CY - Salzburg, Austria DA - 11.05.2015 KW - Zerstörungsfreie Prüfung KW - Oberflächenprüfung KW - Vergleichskörper 1 KW - Sichtprüfung KW - Magnetpulverprüfung KW - Streuflussprüfung KW - Farbeindringprüfung KW - Wirbelstromprüfung KW - Thermografie KW - Radiografie PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-344262 SN - 978-3-940283-68-9 IS - DGZfP BB 152 SP - Mi.2.B.4, 1 EP - 11 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-34426 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jonietz, Florian A1 - Krankenhagen, Rainer A1 - Noack, M. A1 - Gensecke, K. A1 - Wiedenmann, E. T1 - 3D-Formbestimmung mit integrierter thermografischer Qualitätsprüfung N2 - Sowohl die 3D-Formbestimmung als auch die Thermografie sind Verfahren der Qualitätssicherung. Im vorgestellten Projekt wird versucht, die beiden Methoden zusammenzuführen. Das Prinzip des für die Formbestimmung verwendeten 3D-Scanners beruht auf dem bereits bekannten Verfahren der Streifenlichtprojektion. Die Neuartigkeit des hier verwendeten 3D-Scanners besteht darin, dass nicht im sichtbaren, sondern im infraroten Spektralbereich gearbeitet wird. Dadurch wird es möglich, nicht die Reflexion, sondern die Wärmestrahlung des Prüfobjektes nach Absorption der eingebrachten Strahlung auszuwerten. Dies ermöglicht, auch optisch „nicht-kooperative“ Oberflächen zu erfassen. Die Anregung mit Wärmestrahlung stellt das Bindeglied zum Verfahren der aktiven Thermografie für die Detektion verdeckter Schäden dar. Bei letzterem Verfahren wird der Wärmestau über Defekten beim Eindringen der Wärme in die Tiefe des Materials gemessen. Dabei stellen Defekte eine Störung des 3D-Scan-Verfahrens dar, während umgekehrt unregelmäßig geformte Oberflächen das thermografische Verfahren erschweren, d.h. der Messeffekt eines der Verfahren ist ein Störeffekt für das jeweils andere Verfahren. Es wird zum einen der Frage nachgegangen, inwieweit das 3D-Scan-Verfahren durch verdeckte thermische Defekte beeinträchtigt wird, und zum anderen die Möglichkeit untersucht, den vorhandenen 3D-Scanner auch für die aktive Thermografie einzusetzen. Es werden CFK-Proben mit künstlich eingebrachten thermischen Defekten untersucht und die Möglichkeiten und Grenzen der vorhandenen Messapparatur für die Defekterkennung aufgezeigt. T2 - DGZfP-Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - 3D-Formbestimmung KW - Thermografische Qualitätsprüfung KW - Streifenlichtprojektion KW - 3D-Scanner KW - Aktive Thermografie PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-407856 UR - https://jahrestagung.dgzfp.de/Portals/151//doc/Mi.1.A.3.pdf SN - 978-3-940283-85-6 VL - 162 SP - 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-40785 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mooshofer, H. A1 - Boehm, Rainer A1 - Heinrich, W. A1 - Fendt, K. A1 - Goldammer, M. A1 - Kolk, K. A1 - Vrana, J. T1 - Amplitudenbasierte Fehlergrößenbewertung mit SAFT: Auf dem Weg von der bildlichen Darstellung zum Messverfahren N2 - Die Größenbewertung von Anzeigen und die Bestimmung der Nachweisgrenze spielen bei der Ultraschallprüfung eine zentrale Rolle: Sie stellen sicher, dass kritische Ungänzen erfasst und bruchmechanisch behandelt werden können. Bei SAFT wurde bisher die Größe von Ungänzen dadurch bestimmt, dass die räumliche Anzeigenausdehnung im Rekonstruktionsergebnis ausgewertet wird, d.h. die Anzahl von Voxel über die sich eine Anzeige erstreckt. Auf diese Weise lassen sich jedoch nur Defektanzeigen bewerten, die größer oder gleich der Wellenlänge sind. Bei kleinen Defekten versagt diese Methode, d.h. es ist keine Größenbewertung möglich. Außerdem bietet diese Methode keine Aussage über die Nachweisgrenze des Verfahrens. Ein Hauptvorteil von SAFT gegenüber der konventionellen Ultraschallprüfung ist aber gerade die Verbesserung der Nachweisgrenze, denn SAFT steigert das Signal-Rausch-Verhältnis (SNR) gegenüber dem Gefügerauschen und reduziert statistisches Rauschen. Um diesen Hauptvorteil nutzen (und quantifizieren) zu können, wird für SAFT eine Methode zur Nachweisgrenzenbestimmung und zur Größenbewertung der Anzeigen kleiner Ungänzen benötigt. Neben ihrer räumlichen Ausdehnung lassen sich Anzeigen im SAFT-Ergebnis auch durch ihre Amplitude charakterisieren, wenn die Prüfkopfeigenschaften und die geometrischen Verhältnisse beim Scan berücksichtigt werden. Genauer gesagt durch die Amplitudensumme, in die - neben der Echoamplitude - auch die winkelabhängige Streucharakteristik eingeht. Im Folgenden wird dargelegt, dass sich die Amplitudensumme zur Nachweisgrenzenbestimmung und zur Größenbewertung kleiner Ungänzen eignet. Es wird der Zusammenhang zwischen der Amplitudensumme und der Größe von Ungänzen dargestellt, und es wird gezeigt, dass auch die Anzeigenposition und die Form des Prüfobjektes eine Rolle spielen können. Auf dieser Basis wird eine Methode zur Größenbestimmung kleiner Anzeigen im SAFT-Ergebnis entwickelt. Damit lässt sich das SAFT-Ergebnis als Ersatzfehlergröße darstellen, so wie das bei konventioneller Ultraschallprüfung z.B. mit Hilfe von AVG-Diagrammen erfolgt. Durch die Vervollständigung um die Größenbewertung ist SAFT nicht mehr nur ein bildgebendes Verfahren, sondern es kann vielmehr als vollwertiges Messverfahren dienen. T2 - DGZfP-Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - Synthetic aperture focussing technique (SAFT) KW - Defektgrößenbewertung KW - Gewichtete Amplitudensumme KW - Kleine Reflektoren PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-411571 SN - 978-3-940283-85-6 VL - 162 SP - 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-41157 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pelkner, Matthias A1 - Pohl, Rainer A1 - Erthner, Thomas A1 - Stegemann, Robert A1 - Kreutzbruck, Marc A1 - Sergeeva-Chollet, N. T1 - Eddy current testing with high-spatial resolution probes using MR arrays as receiver N2 - Magneto-resistive (MR) sensor arrays are suited for high resolution eddy current testing (ET) of aerospace components due to two significant advantages compared to conventional coil systems. First, to obtain high spatial resolution they can be manufactured down to the µm-regime without losing their outstanding field sensitivity. Secondly, MR technology has a relatively frequency-independent sensitivity in the range of common ET-frequencies thus providing a benefit for low frequency applications. This paper presents measurements using MR array probes consisting of 32 TMR-elements (tunnel magneto resistance), an ASIC, and subsequent readout components. A source for generating the eddy currents inside the material under test is also implemented onboard of the PCB. These probes were developed in the IMAGIC-project* for detection and imaging of surface breaking defects. The performance of the new sensor system has been investigated for several mock-ups, Aluminum and Titanium plate specimens having small adjacent boreholes with diameter of 0.44 mm and micro notches in the µm-range, respectively. To compare our results we used conventional eddy current probes. The MR sensor elements have a length of around 60 µm leading to a nearly 'point like' measurement. Neighbouring boreholes (depth 0.25 mm) with a separation of 0.6 mm between their centres could be resolved with a good SNR, and more important, the boreholes could be confidently distinguished using the TMR-probes. In case of conventional probes a reliable separation was not possible. In this paper we present the MR-ET-probes of the IMAGIC consortium and a comparison with conventional techniques. *The IMAGIC-project ('Integrated Magnetic imagery based on spIntronics Components', 2011 – 2014, project reference: 288381) was funded by the European Commission, Seventh Framework Programme. Further partners involved in the consortium beside BAM and CEA were INESC-ID and INESC-MN (Portugal), Sensitec GmbH (Germany), Tecnatom S.A. (Spain), and Airbus Group (France). T2 - 7th International symposium on NDT in aerospace CY - Bremen, Germany DA - 16.11.2015 KW - TMR KW - GMR KW - Sensor array KW - Eddy current testing (ET) KW - Aerospace PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-344254 SN - 978-3-940283-76-4 N1 - Serientitel: DGZfP-Proceedings – Series title: DGZfP-Proceedings IS - DGZfP-BB 156 SP - We.5.A.4, 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.v. (DGZfP) AN - OPUS4-34425 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Krankenhagen, Rainer A1 - Röllig, Mathias A1 - Hosseini, Seyed A1 - Heckel, Thomas A1 - Gaal, Mate A1 - Schadow, Florian A1 - Brackrock, Daniel A1 - Gower, M. A1 - Lodeiro, M. A1 - Baker, G. T1 - Quantitative Bewertung künstlicher und natürlicher Fehler in Faserverbundwerkstoffen mit aktiver Thermografie und Ultraschall N2 - Im EMRP-Projekt VITCEA werden komplementäre ZFP-Verfahren zur Prüfung von Faserverbundwerkstoffen weiterentwickelt und validiert. In diesem Beitrag werden Ergebnisse verschiedener Techniken der aktiven Thermografie und des Ultraschalls vorgestellt. Die Nachweisempfindlichkeiten bezüglich künstlicher und natürlicher Fehler mit unterschiedlichen lateralen Ausdehnungen und in verschiedenen Tiefen werden miteinander verglichen. T2 - DGZfP Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - CFK KW - GFK KW - Aktive Thermografie KW - Phased Array Ultraschall KW - Luftultraschall PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-410902 SN - 978-3-940283-85-6 VL - BB 162 SP - Di1B1, 1 EP - Di1B1, 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e. V. AN - OPUS4-41090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maiwald, Michael A1 - Gräßer, Patrick A1 - Wander, Lukas A1 - Zientek, Nicolai A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Kern, Simon T1 - Strangers in the Night—Smart Process Sensors in Our Current Automation Landscape N2 - The departure from the current automation landscape to next generation automation concepts for the process industry has already begun. Smart functions of sensors simplify their use and enable plug-and-play integration, even though they may appear to be more complex at first sight. Smart sensors enable concepts like self-diagnostics, self-calibration, and self-configuration/parameterization whenever our current automation landscape allows it. Here we summarize the currently discussed general requirements for process sensors 4.0 and introduce a smart online NMR sensor module as example, which was developed for an intensified industrial process funded by the EU’s Horizon 2020 research and innovation programme (www.consens-spire.eu). T2 - Eurosensors 2017 Conference CY - Paris, France DA - 03.09.2017 KW - Process Monitoring KW - Smart Sensors KW - CONSENS KW - Online NMR Spectroscopy KW - Mini-plant PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-415772 UR - http://www.mdpi.com/2504-3900/1/4/628 DO - https://doi.org/10.3390/proceedings1040628 VL - 1 SP - 628 EP - 631 PB - MDPI CY - Basel AN - OPUS4-41577 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Katsikini, M. A1 - Pinakidou, F. A1 - Paloura, E.C. A1 - Arvanitidis, J. A1 - Ves, S. A1 - Reinholz, Uwe A1 - Ppadomanolaki, E. A1 - Iliopoulos, E. T1 - Simulation of the EXAFS and Raman spectra of InxGa1-xN utilizing the equation of motion routine of FEFF8 N2 - A combined analysis of EXAFS and Raman spectra is applied for the study of InxGa1-xN alloys with 0.3 0.5MeV) X-rays and proved the applicability of the present technique to inspect thick carbon-fiber laminated components. In order to improve the inspection time and image quality of the backscatter image, we used high-resolution (180ìm) digital detector arrays (DDAs). At the end, important applications of the presented X-ray backscatter technique to the aerospace industry are discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray backscatter imaging KW - Twisted-slit collimator KW - NDT KW - Digital detector array (DDA) KW - Stringer KW - Aerospace applications PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322376 UR - https://www.ndt.net/?id=16431 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 8 PB - NDT.net CY - Kirchwald AN - OPUS4-32237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kind, Thomas T1 - Ortung von Spanngliedern zum schadensfreien Bohren im Rahmen von Ertüchtigungsmaßnahmen N2 - Am Beispiel der Ertüchtigung einer Brücke in Bremen wird gezeigt, wie mit den zerstörungsfreien Prüfverfahren (ZfP) Radar- und Ultraschall die genau Lage vorgespannte Bewehrung gefunden bzw. bestätigt werden kann. Im Rahmen von Ertüchtigungsmaßnahmen an Spannbetonbrücken werden häufig Kernbohrungen durchgeführt, die die vorhandenen Spannbewehrungen nicht beschädigen dürfen. Es wird die Vorgehensweise beschrieben, wie mit ZfP ein wesentlicher Beitrag geleistet wird, das Risiko einer Beschädigung zu minimieren und somit eine bessere Planungssicherheit für die Ertüchtigungsmaßnahmen zu schaffen. Dabei werden auch die Grenzen der beiden Verfahren aufgezeigt. T2 - Fachtagung Bauwerksdiagnose 2012 - Praktische Anwendungen zerstörungsfreier Prüfungen und Zukunftsaufgaben CY - Berlin, Germany DA - 23.02.2012 KW - Radar KW - Zerstörungsfreie Prüfung KW - Stahlbeton KW - Ultraschall PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-398225 SN - 978-3-940283-40-5 VL - 134 (Vortrag 11) SP - 1 EP - 7 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin, Germany AN - OPUS4-39822 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Ziegler, Mathias A1 - Kunert, M. A1 - Goldammer, M. T1 - Entwicklung von Referenzprobekörpern für die Standardisierung der Blitzthermografie N2 - Die aktive Thermografie wird in der Industrie zunehmend in verschiedenen Bereichen zur Qualitätssicherung, Zustandsdiagnose und Zustandsüberwachung eingesetzt. Bestehende Normen zur Thermografie beschreiben die Grundlagen, Geräte und Begriffe. In diesem Beitrag wird über ein Projekt berichtet, dessen Ziel die Erarbeitung einer Prüfnorm zur Blitzthermografie ist. Diese sollte neben der Auswahl geeigneter Gerätekomponenten, der Auswertungsverfahren und der Vorgehensweise bei der Prüfung auch die Beschreibung geeigneter Referenzprobekörper enthalten, die eine Bewertung der Messapparatur und eine Qualitätssicherung der Prüfung ermöglichen. T2 - Thermographie-Kolloquium 2011 CY - Stuttgart, Germany DA - 29.09.2011 KW - Aktive Thermografie KW - Blitzanregung KW - Prüfnorm KW - Referenzprobekörper PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246230 SN - 978-3-940283-36-8 VL - 130 SP - 1 EP - 7 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-24623 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartscher, M. A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Neuschaefer-Rube, U. T1 - Application of an industrial CT reference standard for cast freeform shaped workpieces N2 - Industrial computed tomography (CT) today is an important method to analyze defects and to measure the geometry of technical products. The measurement capability of industrial CT often depends on the knowledge of the measurement errors being present. Only with this knowledge, effective corrections are possible by manufacturers, or adapted measurement procedures become possible for the customers. Thus, there is the strong need to have adequate reference standards both for the assessment of general dependencies and for the measurement of task-specific effects. Especially the latter are difficult to assess. This paper shows the application of a versatile dismountable workpiece-near reference body for the use with CT. The reference standard was made from a miniaturized cast aluminium (one-)cylinder head. It can be dismounted into four segments, each featuring reference geometries which enable a registration of CT measured and other reference datasets (e.g. from tactile CMM). The reference standard embodies complex freeform surfaces which are a challenging measurement task for CT and other sensors. Here the application of the reference standard is the study of the influence of material mixes. This is realized by adding pieces of other materials which disturb the mono-material measurement. Results of the application of the reference standard are presented using data from industrial micro-CT systems and CMM reference data. A special emphasis is given on the workflow of the data processing and the data analysis. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Industrial reference standard KW - Computed tomographie KW - Freeform shaped workpieces PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-245532 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (We.4.3) SP - 1 EP - 12 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Badde, Aurelia A1 - Michaelis, Matthias A1 - Berger, U. A1 - Onel, Yener A1 - Meinel, Dietmar A1 - Goebbels, Jürgen T1 - Einsatz von mobilen Röntgenuntersuchungsmethoden im Museum - Zwei Fallbeispiele N2 - Zwei Bildhauermodelle aus dem Georg-Kolbe-Museum Berlin standen zur Restaurierung an. Das kleinere, 'Lucino' (1920), 41cm, wurde hochauflösend mit CT gemessen, da mittels CT sowohl der Herstellungsprozeß einer Gipsstatue als auch der innere Zustand, wie Ergänzungen, Klebungen und Armierungen, festgestellt werden können. Aus den CT Bildern ergab sich eine für die vorher vermutete Gipszusammensetzung ungewöhnliche innere Struktur. Mit einer Freihand bedienten Röntgenpistole zur Messung der Röntgenfluoreszenz wurde daraufhin die Zusammensetzung des Materials der Statuette als Terracotta bestimmt. Durch den Einsatz von Helium als Spülmittel konnten auch leichte Materialien nachgewiesen und so eine Unterscheidung zwischen Gips und gebranntem Ton durchgeführt werden. Aus den CT Daten wurde eine virtuelle Darstellung der äußeren Geometrie gewonnen. Ein damit versuchsweise erstelltes Replik (Rapid Prototyping, 3D-Drucker, TU-Berlin) entsprach nicht den Anforderungen des Museums zur Erstellung einer Gußform für eine Bronzekleinserie der Statuette. Die zweite Statue, die 'Große Nacht' (1930) ist mit ihrer Größe von 2,12m und aufgrund des durch korrodierende Metallarmierung verursachten Schadensbildes nicht mehr transportfähig. Eine in-situ Untersuchung mit dem mobilen Tomographen, der in den 1980ern zur Untersuchung von Bäumen gebaut und jetzt mit einem modernen Flachdetektor und einer Röntgenröhre ausgestattet ist, wird vorgestellt. Die Möglichkeiten acder in-situ CT für große Skulpturen werden anhand der Ergebnisse diskutiert. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 10.05.2010 KW - Mobile CT KW - Mobile RFA PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246956 UR - https://www.ndt.net/?id=10149 SN - 978-3-940283-26-9 VL - 122 SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-24695 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dey, Anika A1 - Casperson, Ralf A1 - Pohl, Rainer A1 - Thomas, Hans-Martin T1 - Die Wirbelstromprüfung als Hilfsmittel für die Schieneninstandhaltung N2 - Die zerstörungsfreie Oberflächenprüfung an verlegten Eisenbahnschienen mit Wirbelstrom hat in den letzten Jahren durch ständige Weiterentwicklung und Verifizierung enorm an Bedeutung gewonnen. Es wurde u.a. angestrebt zuverlässige Planungsgrößen für den Einsatz von Instandhaltungsmaßnahmen zu erhalten, durch deren gezielten Einsatz Risswachstum unterbunden werden kann. Die Ursache für das Wachstum von Rissen in der Schiene liegt in der Materialermüdung des Werkstoffes infolge der Betriebsbelastungen im RadSchiene-Kontakt. Nach einer gewissen Beanspruchungsdauer kommt es an den Kontaktflächen der Fahrkante zu einer Kaltverfestigung des Schienenstahls. Durch fortschreitende Verfestigung des kontaktbeanspruchten Oberflächenbereichs der gehärteten Schicht wird der Werkstoff spröde und es bilden sich feine Risse aus. Die Risse wachsen anfangs unter einem flachen Winkel in das Schieneninnere hinein, neigen dann aber ab einem gewissen Stadium dazu in das Innere des Schienenkopfes abzukippen, was im Extremfall zu einem Schienenbruch führen kann. Diese Rollkontaktermüdungsrisse, auch genannt Head Checks, entstehen bevorzugt in der Fahrkante von bogenäußeren Schienen. Die Anwendung der Wirbelstromprüfung an der Schiene wurde bisher zur Ermittlung der Schädigungstiefe dieser Rollkontaktermüdungsrisse eingesetzt. Das Wirbelstromverfahren besitzt die Eigenschaft, sehr empfindlich auf alle Veränderungen der Materialeigenschaften an der Oberfläche zu reagieren. Daher wurde festgestellt, dass sich neben der Detektion von Rissen auch Fehler wie Eindrückungen oder Schlupfwellen, bis hin zu Materialveränderungen durch Schweißen oder Aufhärtungen in der Schienenoberfläche bestimmen lassen. Die Wirbelstromprüfung besitzt daher das Potenzial, mögliche Orte der Entstehung von Ermüdungsrissen in einem extrem frühzeitigen Stadium nachzuweisen. Ziel ist es, die rissgefährdeten Zonen schon im Zustand der Kaltverfestigung zu identifizieren. Dadurch können sich neue Aspekte für die präventive Schieneninstandhaltung ergeben. T2 - DGZfP-Jahrestagung 2010 - Zerstörungsfreie Materialprüfung ZfP in Forschung, Entwicklung und Anwendung CY - Erfurt, Germany DA - 10.05.2010 PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-214813 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-21481 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Goebbels, Jürgen A1 - Meinel, Dietmar A1 - Paetsch, O. A1 - Prohaska, S. A1 - Zobel, Valentin T1 - Comparison of crack detection methods for analyzing damage processes in concrete with computed tomography N2 - Analyzing damages at concrete structures due to physical, chemical, and mechanical exposures need the application of innovative non-destructive testing methods that are able to trace spatial changes of microstructures. Here, the utility of three different crack detection methods for the analysis of computed tomograms of various cementitious building materials is evaluated. Due to the lack of reference samples and standardized image quality evaluation procedures, the results are compared with manually segmented reference data sets. A specific question is how automatic crack detection can be used for the quantitative characterization of damage processes, such as crack length and volume. The crack detection methods have been integrated into a scientific visualization system that allows displaying the tomography images as well as presenting the results. T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Crack detection KW - Computed tomography KW - Data visualization PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243569 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 2) SP - 1 EP - 8 PB - Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24356 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Duffner, Eric A1 - Gregor, Christian A1 - Bohse, Jürgen T1 - Überwachung der Fertigungsqualität von Faserverbund - Druckbehältern mittels Schallemissionsprüfung N2 - Ziel der Untersuchung ist die Validierung einer Prüfmethodik zur Sicherung der Fertigungsqualität von Faserverbund – Druckbehältern unter realen Fertigungsbedingungen. Das Verfahren basiert auf Merkmalen und zulässigen Grenzwerten, die aus Schallemissionsverläufen bei der Erstdruckprüfung abgeleitet werden. Die Methodik konnte zuvor bereits erfolgreich an Faserverbund – Druckbehältern mit metallischem Liner getestet und patentiert werden. Mit den aktuellen Untersuchungen wurde die Möglichkeit des Erkennens von Fertigungsfehlern in Kohlenstofffaser/Glasfaser – Hybriddruckbehältern mit polymerem Liner evaluiert. Dazu wurden Faserverbund – Druckbehälter mittels Schallemissionsmessung bei einer hydraulischen Erstdruckprüfung überwacht, wie sie (ohne Schallemissionsprüfung) generell zur Qualitätssicherung nach der Fertigung von Faserverbund – Druckbehältern gefordert wird. An Druckbehältern aus einer Serienproduktion wurden die Schallemissionsverläufe registriert und die mittleren Merkmalswerte sowie deren Streuung als Referenz ermittelt. Diese werden mit den Schallemissionsverläufen von Druckbehältern mit gezielt eingebrachten Fertigungsfehlern verglichen. Bei den Fertigungsfehlern handelt es sich um Fehler, die in der Serienproduktion auftreten können und mit den Methoden der herkömmlichen Qualitätssicherung schwer oder gar nicht nachzuweisen sind. Alle untersuchten Druckbehälter wurden im Anschluss an die Erstdruckprüfung auf verschiedene Weise bis zum Versagen (Leckage, Bersten) beansprucht. Damit war es möglich, den tatsächlichen Einfluss der Fertigungsfehler auf den Berstdruck bzw. das Ermüdungsverhalten der Behälter zu verifizieren und die Aussagefähigkeit des Schallemissionsverfahrens zu beurteilen. T2 - 18. Kolloquium Schallemission CY - Wetzlar, Germany DA - 27.10.2011 KW - Faserverbund-Druckbehälter KW - Schallemissionsprüfung KW - Fertigungsüberwachung PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-247881 SN - 978-3-940283-37-5 IS - DGZfP-BB 131 (Vortrag 16) SP - 1 EP - 9 AN - OPUS4-24788 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Caldeira, Rui A1 - Bartusch, Jürgen A1 - Kupnik, M. T1 - Air-coupled ultrasonic ferroelectret receiver with additional DC voltage N2 - Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio. T2 - Eurosensors 2017 CY - Paris, France DA - 3.9.2017 KW - Ultrasonic KW - Air-coupled KW - Cellular polypropylene KW - Transducer KW - Ferroelectret PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-419009 DO - https://doi.org/10.3390/proceedings1040362 VL - 1 IS - 4 SP - Article 362, 1 EP - 4 AN - OPUS4-41900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wachsmuth, Janne T1 - Wellenform basierte Quellenlokalisierung im Vergleich zu konventionellen Methoden N2 - Für eine 10 mm dicke Stahlplatte kann ein Bandpass so gesetzt werden, dass alle vorhandenen Wellenmoden mit derselben Schallgeschwindigkeit eintreffen. Anhand von Ortungsabweichungen und Ortungsunsicherheitswerten kann gezeigt werden, dass im Vergleich zu herkömmlichen Methoden der Quellenortung die Ortungsgenauigkeit durch eine Frequenzfilterung verbessert werden kann. T2 - 18. Kolloquium Schallemission CY - Wetzlar, Deutschland DA - 27.10.2011 KW - Schallemissionsprüfung KW - Ermüdungsrisswachstum KW - Korrosion PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246612 SN - 978-3-940283-37-5 SP - 1 EP - 6 PB - DGZfP-BB 131 AN - OPUS4-24661 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Kolkoori, Sanjeevareddy A1 - Bellon, Carsten T1 - Quantitative simulation of back scatter X-ray imaging and comparison to experiments N2 - X-ray backscatter imaging is a well established NDT technique to inspect complex objects using only a single-sided access. In difference to conventional transmission X-ray radiography, the X-ray backscatter imaging utilizes the scattered radiation caused by the Compton scattering effect. In order to achieve high backscatter intensities from a test object, it is necessary to optimize the backscatter system parameters namely the angle between source and slit camera, the slit collimator system, the shielding between source and scatter camera, and the type of detector. In addition, the scatter phenomena in to the investigated object need to be understood. In this contribution, we present a Monte Carlo model McRay which considers all relevant single and multiple interactions of photons and electrons. This model can be used to simulate back scatter techniques. It allows not only calculating the scatter image for a given experimental setup but also registering the spectrum of the detected scattered photons. Both aspects are important to understand the imaging process, to interpret the results, and to optimize the backscatter camera investigated here. Additionally experimental results will be presented and compared with simulations. T2 - 19th World Conference on Nondestructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Radiology KW - Back-scatter techniques KW - Simulation KW - Monte Carlo methods KW - Measurements PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-365897 SN - 978-3-940283-78-8 VL - 158 SP - 1 EP - 11 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung (DGZfP) CY - Berlin, Germany AN - OPUS4-36589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter A1 - Krebs, Holger T1 - Boiling liquid expanding vapour explosion (BLEVE) of peroxy-fuels: Experiments and computational fluid dynamics (CFD) simulation N2 - Fire and explosion hazards associated with storage and transportation of flammable materials have been a matter of great interest in the recent times. BLEVE is a scenario that occurs when a closed fuel container is subjected to heat for a longer duration. Such events are disastrous to human beings and assets both. In the past there have been numerous studies on BLEVEs and fireballs of hydrocarbon fuels, e.g. kerosene, gasoline, LPG, LNG and others. Though, the fireballs of peroxy-fuels are not looked into detail as such. This article tries to overcome this lack of knowledge. Both, experimental investigation and CFD simulations are performed to measure and predict the fireball characteristics of a peroxy-fuel. Due to thermal decomposition in the liquid phase and active oxygen content a peroxy-fuel fireball burns at a very fast rate and emit higher thermal radiation whereas exhibits smaller diameter and elevation compared to hydrocarbons. That eventually leads to consideration of larger safety distances from them which are also verified by CFD results. KW - BLEVE KW - Hydrocarbons KW - Peroxy-fuels KW - Safety distances KW - CFD simulation PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-334184 DO - https://doi.org/10.1016/j.egypro.2015.02.082 SN - 1876-6102 VL - 66 SP - 149 EP - 152 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-33418 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kraehnert, R. A1 - Ortel, Erik A1 - Paul, B. A1 - Eckhardt, B. A1 - Kanis, M. A1 - Liu, R. A1 - Antoniou, A. T1 - Electrochemically dealloyed platinum with hierarchical pore structure as highly active catalytic coating N2 - Micro structured reactors are attractive candidates for further process intensification in heterogeneous catalysis. However, they require catalytic coatings with significantly improved space-time yields compared to traditional supported catalysts. We report the facile synthesis of homogeneous nanocrystalline Pt coatings with hierarchical pore structure by electrochemical dealloying of amorphous sputter-deposited platinum silicide layers. Thickness, porosity and surface composition of the catalysts can be controlled by the dealloying procedure. XPS analysis indicates that the catalyst surface is primarily composed of metallic Pt. Catalytic tests in gas-phase hydrogenation of butadiene reveal the typical activity, selectivity and activation energy of nanocrystalline platinum. However, space time yields are about 13 to 200 times higher than values reported for Pt-based catalysts in literature. The highly open metallic pore structure prevents heat and mass transport limitations allowing for very fast reactions and reasonable stability at elevated temperatures. KW - Pt catalysts KW - Pt–Si layers KW - Scanning Electron Microscopy (SEM) KW - Transmission Electron Microscopy (TEM) KW - pore structure KW - electrochemical dealloying PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351393 DO - https://doi.org/10.1039/C4CY00851K SN - 2044-4753 SN - 2044-4761 VL - 5 IS - 1 SP - 206 EP - 216 PB - RSC Publ. CY - Cambridge AN - OPUS4-35139 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hemmann, Felix A1 - Agirrezabal-Telleria, Iker A1 - Jäger, Christian A1 - Kemnitz, E. T1 - Quantification of acidic sites of nanoscopic hydroxylated magnesium fluorides by FTIR and 15N MAS NMR spectroscopy N2 - Lewis and Brønsted sites were quantified in a series of weak acidic hydroxylated magnesium fluorides by Fourier transform infrared spectroscopy (FTIR) and solid state nuclear magnetic resonance spectroscopy (NMR) with pyridine as probe molecule. Molar extinction coefficients, which are necessary for quantitative FTIR measurements, were calculated by an easy approach. It utilizes the fact that both signals, used for the quantification by FTIR, are caused by the same deformation vibration mode of pyridine. Comparison of quantitative FTIR experiments and quantification by NMR shows that concentrations of acidic sites determined by FTIR spectroscopy have to be interpreted with caution. Furthermore, it is shown that the transfer of molar extinction coefficients from one catalyst to another may lead to wrong results. Molar extinction coefficients and concentrations of acidic sites determined by FTIR spectroscopy are affected by grinding and probably the particle size of the sample. High temperature during FTIR experiments has further impact on the quantification results. KW - Acidity KW - Fluoride catalyst KW - Infrared spectroscopy KW - Adsorption of pyridine KW - Molar extinction coefficient determination PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351448 DO - https://doi.org/10.1039/C5RA15116C SN - 2046-2069 VL - 5 IS - 109 SP - 89659 EP - 89668 PB - RSC Publishing CY - London AN - OPUS4-35144 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nguyen, Thi Yen A1 - Rademann, K. A1 - Emmerling, Franziska T1 - Direct evidence of polyamorphism in paracetamol N2 - While polymorphism is a common phenomenon in the crystallization processes of organic compounds, polyamorphism has gained importance only recently. Using sophisticated sample environments and applying in situ scattering methods and vibrational spectroscopy, the complete crystallization process of organic compounds from solution can be traced and characterized. Diffuse scattering from amorphous intermediates can be investigated by analyzing the atomic pair distribution function (PDF) to gain further insights into molecular pre-orientation. The crystallization behavior of paracetamol was studied exemplarily under defined, surface-free conditions. Based on the choice of the solvent, the formation of different polymorphs is promoted. The thermodynamically stable form I and the metastable orthorhombic form II could be isolated in pure form directly from solution. For both polymorphs, the crystallization from solution proceeds via a distinct amorphous precursor phase. PDF analyses of these different amorphous states indicate a specific pre-orientation of the analyte molecules introduced by the solvent. The resulting crystalline polymorph is already imprinted in these proto-crystalline precursors. Direct experimental evidence for the polyamorphism of paracetamol is provided. PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351366 DO - https://doi.org/10.1039/C5CE01583A SN - 1466-8033 VL - 17 IS - 47 SP - 9029 EP - 9036 PB - Royal Society of Chemistry CY - London, UK AN - OPUS4-35136 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Gollwitzer, Christian A1 - Fratzscher, Daniel A1 - Ewert, Uwe A1 - Jaenisch, Gerd-Rüdiger T1 - Simulation of complex scan paths for 3D reconstruction N2 - X-ray computed tomography (CT) is a volumetric (3D) Imaging diagnostic method, well established in the medical field, and in industrial NDE as well. Developments in industrial CT aim to extent the applicability to complex structures, which do not allow the access of all directions. This are e.g. limited view, data and angle CT applications. New reconstruction algorithms are required on one side, and the accuracy has to be improved on the other side. Numerical Simulation can support such developments by providing well defined data sets for the testing of reconstruction algorithms. This approach of virtual CT is realized within the radiographic simulator aRTist, developed by BAM. The poster shows the possibilities of this tool to consider complex scan paths. Simulated data sets have been reconstructed by an versatile backprojection algorithm. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Radiographie KW - Computer-Simulation KW - 3D-Rekonstruktion PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243928 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 17) SP - 1 EP - 4 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abbott, A. P. A1 - Abolibda, T. Z. A1 - Davis, S.J. A1 - Emmerling, Franziska A1 - Lourdin, D. A1 - Leroy, E. A1 - Wise, W. R. T1 - Glycol based plasticisers for salt modified starch N2 - Starch is one of the most common and easily obtained natural polymers, making it attractive as a potential bio-based alternative to synthetic polymers. This study shows that a simple quaternary ammonium salt combined with urea or glycols forms effective modifiers that produce flexible plastics with good mechanical properties that are comparable to some polyolefin plastics. The processing conditions are shown to significantly affect the structure of the polymer which has a concomitant effect upon the mechanical and physical properties of the resulting plastic. Using a glycerol based modifier results in a totally sustainable and biodegradable material which can be injection moulded. KW - biodegradable material KW - flexible plastics KW - injection moulded PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351426 DO - https://doi.org/10.1039/C4RA06220E SN - 2046-2069 VL - 4 IS - 76 SP - 40421 EP - 40427 PB - RSC Publishing CY - London AN - OPUS4-35142 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gollwitzer, Christian A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Ewert, Uwe A1 - Jaenisch, Gerd-Rüdiger T1 - On POD estimations with radiographic simulator aRTist N2 - The computer simulation of radiography is applicable for different purposes in NDT such as for the qualification of NDT systems, the optimization of system parameters, feasibility analysis, model-based data interpretation, education and training of NDT/NDE personnel, and others. Within the framework of the European project PICASSO simulators will be adapted to support reliability assessments of NDT tasks. The radiographic simulator aRTist developed by BAM is well suited for this task. It combines analytical modelling of the RT inspection process with the CAD-orientated object description applicable to various industrial sectors such as power generation, aerospace, railways and others. The analytic model includes the description of the radiation source, the interaction of Radiation with the material of the part, and the detection process with special focus to DIR. To support reliability estimations the simulation tool is completed by a tool for probability of detection (POD) estimation. It consists of a user interface for planning automatic simulation runs with varying parameters, specifically defect variations. Further, an automatic image analysis procedure is included to evaluate the defect visibility and calculate the POD therefrom. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Radiographie KW - Computersimulation KW - Probability of detection PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-245092 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Tu.2.3) SP - 1 EP - 8 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24509 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A. A1 - Kutscher, D. J. A1 - Rottmann, L. A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Bettmer, J. T1 - Combination of single particle ICP-QMS and isotope dilution analysis for the determination of size, particle number and number size distribution of silver nanoparticles N2 - Single particle ICP-MS (spICP-MS) has gained great influence in the analysis of engineered nanoparticles (NPs) due to its simplicity, speed and ability to obtain a particle number size distribution. Despite its many advantages, the method is hampered by matrix effects affecting the sensitivity of the instruments. Consequently, over- or underestimated particle sizes might be obtained. To overcome these challenges, we present in this work the detection of both Ag isotopes with a quadrupole mass spectrometer for the application of isotopic dilution analysis (IDA) in combination with spICP-MS. Here, the isotopes are measured sequentially using the conventional spICP-MS integration time of 10 ms. Citrate stabilized Ag NPs of a spherical shape with the nominal diameters of 30, 40, 50 and 80 nm have been investigated. The experimental concept of adding ¹⁰⁹Ag+ solutions to the NP suspensions resulted in the NP Spikes being only visible in the ¹⁰⁷Ag trace. Therefore, a maximum of 45% of the particles was detected compared to that by conventional spICP-MS. A modified mass flow equation was applied to determine the particle sizes, particle size distributions and particle number concentrations of various Ag NPs. The addition of different spike concentrations between 0.5 and 4 mg L⁻¹ ¹⁰⁹Ag resulted in similar particle diameters, suggesting that the calculated diameter might be independent of the spike concentration. This would have the advantage that no size information would be needed before the analysis. By analyzing Ag NP suspensions in a simulated seawater matrix, we demonstrate its significant influence on the particle size determination using conventional spICP-MS. A lower transport efficiency of 6.1% was found in the matrix compared to 7.3% without the matrix. In our approach, the addition of the Matrix influenced the NP intensity stronger than the spike signal, resulting in slightly smaller diameters using IDA–spICP-MS with the matrix compared to the results without the matrix. On the other hand, the IDA–spICP-MS approach with the matrix can result in equivalent results for the particle sizes compared with conventional spICP-MS using suspensions without the matrix. Due to the lower instrument sensitivity in the matrix, a diameter of 30 nm was found to be close to the detection limit of the instrument. KW - Ag nanoparticles KW - Single particle ICP-MS KW - Matrix influence KW - Isotope dilution analysis PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-376490 DO - https://doi.org/10.1039/c6ja00137h SN - 0267-9477 VL - 31 IS - 10 SP - 2045 EP - 2052 AN - OPUS4-37649 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neubert, Sebastian A1 - Pittner, Andreas A1 - Rethmeier, Michael T1 - Experimental determination of TRIP parameter K for mild- and high strength low alloy steels and a super martensitic filler material N2 - A combined experimental numerical approach is applied to determine the transformation induced plasticity (TRIP)-parameter K for different strength low-alloy steels of grade S355J2+N and S960QL as well as the super martensitic filler CN13-4-IG containing 13 wt% chromium and 4 wt% nickel. The thermo-physical analyses were conducted using a Gleeble® 3500 facility. The thermal histories of the specimens to be tested were extracted from corresponding simulations of a real gas metal arc weldment. In contrast to common TRIP-experiments which are based on complex specimens a simple flat specimen was utilized together with an engineering evaluation method. The evaluation method was validated with literature values for the TRIP-parameter. It could be shown that the proposed approach enables a correct description of the TRIP behavior. KW - Transformation induced plasticity (TRIP) KW - Phase transformation KW - High-strength low-alloy steel KW - Super martensitic filler material KW - Thermo physical simulation KW - Gleeble experiments PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-367297 DO - https://doi.org/10.1186/s40064-016-2474-0 VL - 5 IS - 575 SP - Paper 754, 1 EP - 16 PB - SpringerPlus AN - OPUS4-36729 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tölle, Florian A1 - Gumenyuk, Andrey A1 - Gebhardt, Moritz Oliver A1 - Rethmeier, Michael T1 - Post-weld residual stress mitigation by scanning of a defocused laser beam N2 - High welding residual stresses can cause service life reducing consequences. Even though many processes have been developed to reduce these stresses, they are only applicable for wider welds and simple component geometries or are cost-intensive, respectively. The presented method uses a defocused beam after welding for heating the material regions on both sides of the weld. In this way, the welding stresses are decreased without contacting the surfaces using the available equipment. Different process parameters could be used depending on the component geometry and the laser power. The mechanism and the influence of the process parameters were investigated by FEM-simulation and experiments on S355J2+N steel and showed a stress reduction of about 73%. T2 - Lasers in Manufacturing 2011 - Proceedings of the Sixth International WLT Conference on Lasers in Manufacturing CY - Munich, Germany DA - 23.05.2011 KW - Residual stresses KW - Stress reduction KW - High energy beam welding KW - Post-weld heat treatment KW - Laser scanner optics PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-238482 DO - https://doi.org/10.1016/j.phpro.2011.03.052 SN - 1875-3892 VL - 12 IS - 1 SP - 410 EP - 418 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-23848 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Bellon, Carsten A1 - Hohendorf, Stefan A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Nusser, A. A1 - Freitag, M. A1 - Bücherl, T. A1 - Bar, D. A1 - Mor, I. A1 - Tamin, N. A1 - Weiss-Babai, R. A1 - Bromberger, B. A1 - Dangendorf, V. A1 - Tittelmeier, K. T1 - Computed tomography with X-rays and fast neutrons for restoration of wooden artwork N2 - The objects of this investigation were sculptures taken from a ca. three hundred years old baroque epitaph of a church in Tonning, a town in Northern Germany. Around 1900 it was found in a disastrous state heavily damaged by wood-worm. At that time, the whole artwork was treated with the tar extract carbolineum as a remedy. Nowadays, this substance has been identified as carcinogenic, and its presence can be perceived by its stench and visually at certain spots on the surface where it has penetrated the covering paint. A gold-painted sculpture of a massive wooden skull was interrogated with X-rays and fast neutrons to investigate the internal distribution of the carbolineum. The X-ray tomography, with its excellent spatial resolution revealed galleries left over from the worm infestation in the outer areas and cracks in the central region. The golden color coating appeared as a thick and dense layer. In comparison the tomography with fast neutrons, though being of lower resolution and yet unresolved artefacts revealed sections of slightly different densities in the bulk of the wood. These differences we attribute to the differences in the distribution of the impregnant in the wood, visible due to its higher hydrogen content making it less transparent for neutrons. T2 - WCNR-10 - 10th World conference on neutron radiography CY - Grindelwald, Switzerland DA - 05.10.2014 KW - Computed tomography KW - Neutron radiology KW - Conservation of wooden artwork PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323050 DO - https://doi.org/10.1016/j.phpro.2015.07.066 SN - 1875-3892 VL - 69 SP - 472 EP - 477 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-32305 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Üstündag, Ö. A1 - Avilov, V. A1 - Gumenyuk, Andrey A1 - Rethmeier, Michael T1 - Full penetration hybrid laser arc welding of up to 28 mm thick S355 plates using electromagnetic weld pool support N2 - The laser hybrid welding process offers many advantages regarding deep penetration, increased welding velocity and with the help of the supplied filler wire an improved bridgeability to gap and misalignment tolerances. High power laser systems with a power of approx. 30 kW are already available on the market. Nevertheless, multi-layer technology with an arc process is still used for welding of plates from a thickness from 20 mm. A potential cause is the process instability with increasing laser power. It is inevitable that gravity drop-out due to the high hydrostatic pressure at increasing wall thickness especially at welding in flat position and with a low welding speed. The surface tension decreases with increasing root width resulting from low welding velocities. To prevent such inadmissible defects of the seam a use of weld pool support is required. Usual weld pool support systems such as ceramic or powder supports require a mechanical detachment which is time-consuming. The electromagnetic weld pool support system described in this work shows an alternative weld pool support which works contactless. It is based on generating Lorentz forces in the weld pool due to oscillating magnetic field and induced eddy currents. This innovative technology offers single pass welds up to 28 mm in flat position and reduced welding velocity with a laser power of just 19 kW. It also leads to improved mechanical-technological properties of the seams because of the slow cooling rate. With usage of an electromagnetic weld pool support the limitation of the hybrid laser arc welding process in the thick sheet metal will be extend. KW - Electromagnetic weld pool support KW - Hybrid laser arc welding KW - Thick-walled steel KW - Single pass welding PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-468276 DO - https://doi.org/10.1088/1742-6596/1109/1/012015 SN - 1742-6596 VL - 1109 SP - 1 EP - 7 PB - IOP Publ. AN - OPUS4-46827 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dmitriev, A. I. A1 - Österle, Werner ED - Österle, Werner ED - Zhang, G. T1 - The role of solid lubricants for brake friction materials N2 - This review article comprises of three parts. Firstly, reports of brake manufacturers on the beneficial impact of solid lubricants for pad formulations are surveyed. Secondly, since tribofilms were identified to play a crucial role in friction stabilization and wear reduction, the knowledge about tribofilm structures formed during automotive braking was reviewed comprehensively. Finally, a model for simulating the sliding behavior of tribofilms is suggested and a review on modelling efforts with different model structures related to real tribofilms will be presented. Although the variety of friction composites involved in commercial brake systems is very broad, striking similarities were observed in respect to tribofilm nanostructures. Thus a generalization of the tribofilm nanostructure is suggested and prerequisites for smooth sliding performance and minimal wear rates have been identified. A minimum of 13 vol.% of soft inclusions embedded in an iron oxide based tribofilm is crucial for obtaining the desired properties. As long as the solid lubricants or their reaction products are softer than magnetite, the main constituent of the tribofilm, the model predicts smooth sliding and a minimum of wear. KW - Solid lubricant KW - Friction KW - Automotive braking KW - Tribofilm KW - Sliding simulation KW - MCA-modeling PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-355973 UR - www.mdpi.com/journal/lubricants DO - https://doi.org/10.3390/lubricants4010005 SN - 2075-4442 VL - 4 IS - 1 SP - 5 EP - 26 PB - MDPI CY - Basel, Switzerland AN - OPUS4-35597 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krause, Martin A1 - Effner, Ute A1 - Müller, Sabine A1 - Nowak, Thomas Rudolf A1 - Vergin, Dirk T1 - 3D-SAFT Imaging von Streuern in Brettschichtholz N2 - Aktuell wird die Ultraschallechotechnik für Holzbauteile genutzt, indem aus der Abschattung eines ansonsten stabilen Rückwandechos auf Auffälligkeiten im Holzbauteil geschlossen wird. Dabei werden Transversalwellen (Mittenfrequenz 50 kHz) mit der Polarisationsrichtung in Faserrichtung (L) angewendet. In einem 2012 abgeschlossenen Forschungsvorhaben wurde nun die direkte Abbildung von Streuern durch anisotrope SAFT-Rekonstruktion entwickelt. Dazu werden flächig aufgenommene Ultraschallmessdaten mit automatisiert scannenden Druck- und Scherwellenköpfen erzeugt und auf Basis anisotroper Geschwindigkeitsverteilungen rekonstruiert. Benutzt werden die auch häufig für Beton eingesetzten trocken ankoppelnden Punktkontakt-Prüfköpfe. Da damit auch intensive Wellen an der Oberfläche erzeugt werden, entstehen im Material zusätzliche Kopfwellen, die ebenfalls bei der Rekonstruktion berücksichtigt werden. Da die Wellengeschwindigkeiten in Holz individuell stark schwanken, wird eine interaktive Auswertetechnik zur Ermittlung der Materialkonstanten benutzt. Für die Messungen werden Druckwellen sowie Scherwellen in zwei Polarisationsrichtungen verwendet. Die Messungen erfolgen sowohl mit automatischen Scannersystemen als auch mit einem linearen Prüfkopf-Array (kommerziell erhältlicher multistatischer Messkopf). Gezeigt werden Ergebnisse an Bauteilen mit künstlichen und realen Fehlstellen. Das Forschungsprojekt wurde gefördert vom Bundesamt für Bau- und Raumordnung (BBR, Zukunft Bau). T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Holz KW - Ultraschallecho KW - Anisotropie KW - Rekonstruktionsrechnung KW - Fehlstellenortung PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-293509 SN - 978-3-940283-49-8 IS - Poster 8 SP - 1 EP - 9 AN - OPUS4-29350 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Manuel A1 - Klimakow, Maria A1 - Rademann, K. A1 - Emmerling, Franziska T1 - Fast and efficient synthesis of a host guest system: a mechanochemical approach N2 - An unusually fast and effective synthesis procedure for a host guest system consisting of a metal organic framework (MOF) and a polyoxometalate (POM) is described. The material was synthesised mechanochemically and the evolution of the structure was monitored ex and in situ using synchrotron X-ray diffraction (XRD). KW - Mechanochemistry KW - MOF KW - in situ PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-354910 UR - http://pubs.rsc.org/en/Content/ArticleLanding/2016/CE/C5CE01868D#!divAbstract DO - https://doi.org/10.1039/C5CE01868D VL - 18 IS - 7 SP - 1096 EP - 1100 AN - OPUS4-35491 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krankenhagen, Rainer A1 - Groll, E.T. A1 - Kalisch, U. A1 - Maierhofer, Christiane A1 - Mecke, R. A1 - Meinhardt, J. A1 - Myrach, Philipp A1 - Schiller, M. A1 - Seidl, T. T1 - Untersuchung der Putzritzungen am Magdeburger Dom mit aktiver Thermografie und optischen 3D-Messverfahren N2 - Eines der bedeutendsten Kunstwerke des Magdeburger Doms sind die Putzritzungen am Ostflügel des Kreuzgangs aus dem 13. Jahrhundert. Der größte Teil der einzelnen Putzoberflächen sind Ausbesserungen oder Neuverputzungen aus verschiedenen Restaurierungs- oder Reparaturphasen. In dem von der Forschungsinitiative Zukunft Bau geförderten Projekt zur 3D-Kartierung von Bauwerksoberflächen wurden Untersuchungen zur Erfassung der Schäden an diesen Putzritzungen mit optischen 3D-Messverfahren und der aktiven Thermografie durchgeführt. Dabei wurden bei den optischen Verfahren hochauflösende Techniken zur Erfassung der Oberflächentopologie (Stereophotogrammmetrie) und zur Vermessung der Rissstrukturen und Ausbeulungen (3D-Trackingverfahren) eingesetzt. Die Zuordnung der Signaturen in den Thermogrammen zu Hohlstellen sowie Materialergänzungen und -ersatz wird diskutiert. Weiterhin erfolgt ein Vergleich der Ergebnisse mit Messungen an neu freigelegten Putzbereichen. T2 - Thermographie-Kolloquium 2013 CY - Leinfelden-Echterdingen, Germany DA - 26.09.2013 KW - Aktive Thermografie KW - Stereophotogrammetrie KW - Trackingsystem KW - Risse KW - Putz KW - Mauerwerk KW - Denkmalpflege PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-293987 SN - 978-3-940283-52-8 IS - DGZfP-BB 143 (Vortrag 6) SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-29398 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Myrach, Philipp A1 - Steinfurth, Henrik T1 - Einfluss von Material, Messparametern und Umgebungsbedingungen auf die Nachweisempfindlichkeit der Blitzthermografie N2 - Dieser Beitrag fasst die Untersuchungsergebnisse zu den Verfahrensgrenzen der Blitzthermografie zur Ortung und Charakterisierung von Fehlstellen in Metallen zusammen. Regeln zur Abschätzung von Eindringtiefe und Tiefenauflösung werden vorgestellt und überprüft. Weiterhin werden Vorgehensweisen zur Optimierung des Intensitätskontrastes von Fehlstellenanzeigen vorgestellt. Einfache analytische Abschätzungen werden durch eine Vielzahl von experimentellen Untersuchungen an Kupfer- und Stahl-Probekörpern ergänzt. Dabei wurden sowohl die Parameter der Blitzlichtanregung als auch der Messwerterfassung umfassend variiert. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-285733 SN - 978-3-940283-49-8 IS - Di.2.A.1 SP - 1 EP - 8 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-28573 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -